+ All Categories
Home > Documents > Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand...

Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand...

Date post: 28-May-2020
Category:
Upload: others
View: 13 times
Download: 0 times
Share this document with a friend
16
Hand Fracture System with Small Bone External Fixation System Product Overview
Transcript
Page 1: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Hand Fracture Systemwith Small Bone External Fixation System

Product Overview

Page 2: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Acumed® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation for metacarpal and phalangeal fractures, as well as fixation for fusions and osteotomies. This comprehensive system contains plates for fractures of the metacarpal neck, fractures of the base of the first metacarpal, avulsion fractures, and rotational malunions. Additionally, the system contains standard-shaped, cut-to-length and bend-to-fit plates and hexalobe lag screws for less complicated fractures.

Low-profile plates and screws and a rounded-edge plate cutter are designed to minimize soft tissue irritation. Versatile screws, customizable plates, and dedicated instrumentation offer a comprehensive system to streamline the surgical experience.

Page 3: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Sys

tem

Fea

ture

s

Plates and ScrewsThe Acumed Hand Fracture System offers plates in 0.8 mm and 1.3 mm thicknesses.

1.3 mm thickness

T-Plate Straight Plate Compression Plate

Rolando Fracture Hook Plate

Curved Medial/Lateral Plate

Rotational Correction Plate

Offset Plate

Metacarpal Neck Plate, Left and Right

Avulsion Fracture Plate

0.8 mm thickness

Page 4: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Customizable Standard PlatesMost plates can be cut to length and bent to fit to better treat a wide variety of fracture patterns. A plate cutter included in the system is designed to create a smooth, rounded edge.

Multiple Choices, Multiple Options

0.8 mm T-Plate

Note: Not all configurations and options are shown

1.3 mm Straight Plate

Diaphyseal Fractures0.8 Curved Medial/Lateral Plate

Distal Phalangeal Fractures0.8 Curved Medial/Lateral Plate

Comminuted Fractures0.8 Offset Plate

Page 5: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Sys

tem

Fea

ture

s

Avulsion FractureThe 0.8 mm Avulsion Hook Plate is designed for periarticular fractures where the fragment contains a soft tissue insertion.

Rolando Fracture The 1.3 mm Rolando Fracture Hook Plate is designed to treat a Y- or T-shaped fracture pattern at the base of the first metacarpal.

Metacarpal Neck FractureThe 1.3 mm Metacarpal Neck Plate has three distally pointing converging screws to provide metacarpal head fixation.

Rotational Malunion OsteotomyThe 1.3 mm Rotational Correction Plate system includes a Rotational Osteotomy Cutting Guide designed to facilitate placement and orientation of the cut for rotational osteotomies of the metacarpals.

Specialty Plates

Page 6: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

15°

Locking Variable Angle Screws Hexalobe MultiScrews allow for variable angle screw insertion up to 15 degrees in any direction, for a total of 30 degrees.

Hexalobe Lag ScrewsThese screws are designed to be used as an adjunct to plate fixation or for fractures that can be treated with lag screws alone. Acumed’s 1.5 mm and 2.3 mm Hexalobe Lag Screws do not require overdrilling of the near cortex.

Versatile Hexalobe MultiScrewsThe 1.5 mm and 2.3 mm Hexalobe MultiScrews can be used in plates of either 0.8 mm or 1.3 mm thickness. The SaveLock Compression Sleeve allows these screws to function as both locking and nonlocking screws.

Screw Technology

Page 7: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Sys

tem

Fea

ture

s

Small Bone FixatorWith a straightforward application, this fixator’s modular design enables pins to be placed in multiplanar arrangements, allowing the frame to be built around the fractures.

Small Bone DistractorThis lightweight, low-profile fixator can be adjusted to the amount of distraction/compression desired by the surgeon.

Small Bone External Fixation System

Page 8: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

SaveLock Compression SleeveThe instrument covers the threads on the head of the Hexalobe MultiScrews while compressing the plate to the bone when inserting the screw. The sleeve is threaded over the screw head only and prevents these threads from engaging the plate when inserting the screw shaft into the bone.

Key Instruments

Plate CutterFracture-specific and standard plates can

be bent to fit and cut to length to better treat a wide variety of fracture patterns. A plate

cutter included in the system is designed to create a smooth, rounded edge.

Page 9: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Sys

tem

Fea

ture

s

Percutaneous Bone ClampThe 1. 1mm/2.0 mm clamp is a double-barreled drill guide that aids in provisional fixation and drilling. One barrel is used to insert a K-wire across the fracture while the other barrel guides the drill.

Rotational Osteotomy Cutting GuideThis guide is designed to facilitate placement and orientation of cuts for rotational osteotomies of the metacarpals.

Single Pointed Reduction ForcepsSharp end points engage the divots between screw holes on the plate to hold it securely to the bone during plate placement and fracture reduction.

Key Instruments

Page 10: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Rolando Fracture Hook Plate First metacarpal base fracture fixation

Small Bone Distractor Metacarpal osteotomy and

subsequent lengthening

Curved Medial/Lateral Plate Proximal phalanx fracture fixation

Page 11: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

X-R

ays

Metacarpal Neck Plate Fifth metacarpal neck fracture fixation

Straight Plate Metacarpal phalange fusion

T-Plate and Lag Screw Third metacarpal fracture

Page 12: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

*For reference only. For full instructions, see the current Hand Fracture System Surgical Technique.

Exposure

Exposure Osteotomy Cut

Plate Placement and Rotational Correction

Exposure and Fracture Reduction Plate Placement

Proximal Screw Insertion

Fracture Reduction and Plate Placement

Drilling Distal Screw Hole

Determining Screw Length

1.3 mm Rolando Fracture Hook Plate*

1.3 mm Metacarpal Neck Plate*

1.3 mm Rotational Correction Plate*

Page 13: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Sur

gica

l Tec

hniq

ue O

verv

iew

Distal Screw Insertion

Osteotomy Compression

Proximal Screw Insertion

Screw InsertionClosure and Postoperative Protocol

Closure and Postoperative Protocol

Distal Cluster Screw Preparation

Screw InsertionDrilling Proximal Holes

Proximal Screw Insertion

Final Screw Insertion

Page 14: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Prod

uct i

n Po

rtfo

lio

Prod

uct N

ot in

Po

rtfo

lio

Part

ial O

ff erin

g

Prod

uct i

n D

evel

opm

ent

Acu

med

DeP

uy

Synt

hes

Stry

ker

Smith

&

Nep

hew

Shoulder

Clavicle/Scapula

Supe

rior C

lavi

cle

Plat

es

Ant

erio

r Cla

vicl

e Pl

ates

Hoo

k Pl

ates

Scap

ula

Bor

der P

late

s

Gle

noid

Pla

tes

Acr

omio

n Pl

ates

Cla

vicl

e Sc

rew

s/Pi

ns

Humerus

Prox

imal

Hum

eral

Nai

ls

Prox

imal

Hum

eral

Pla

tes

Mid

shaf

t Pla

tes

Elbow

Distal Humerus

90

/90

Pla

tes

Para

llel P

late

s

Exte

rnal

Fix

atio

n

Proximal Ulna

Ole

cran

on P

late

s

Cor

onoi

d Pl

ates

Prox

imal

Uln

a N

ails

Radial Head

Radi

al H

ead

Plat

es

Radi

al H

ead

Repl

acem

ent,

Shor

t Ste

m

Radi

al H

ead

Repl

acem

ent,

Long

Ste

m

Wrist

Midshaft Forearm

Uln

a Pl

ates

Ana

tom

ic M

idsh

aft V

olar

Ra

dius

Pla

tes

Dor

sola

tera

l Mid

shaf

t Ra

dius

Pla

tes

Uln

a N

ails

Radi

us N

ails

Distal Ulna

Dis

tal U

lna

Plat

es

Uln

ar S

hort

enin

g Pl

ates

Distal Radius

Vol

ar D

ista

l Rad

ius

Plat

es

Dor

sal D

ista

l Rad

ius

Plat

es

Radi

al S

tylo

id P

late

Dor

sal R

im P

late

s

Dor

sal L

unat

e Pl

ates

Vol

ar L

unat

e Pl

ates

Wris

t Spa

nnin

g Pl

ates

Exte

rnal

Fix

atio

n

Hand

Carpal

Wris

t Fus

ion

Niti

nol S

tapl

es

Phalangeal & Metacarpal

Han

d Fr

actu

re P

late

s

MC

P Fu

sion

Pla

tes

Exte

rnal

Fix

atio

n

Spec

ialty

Han

d Pl

ates

Screws

Headless

Con

tinuo

us C

ompr

essi

on

Diff

eren

tial P

itch

Headed

Part

ial T

hrea

d

Full

Thre

ad

Page 15: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Upp

er E

xtre

mit

y C

ompe

tito

r P

rodu

ct C

ompa

riso

n

Prod

uct i

n Po

rtfo

lio

Prod

uct N

ot in

Po

rtfo

lio

Part

ial O

ff erin

g

Prod

uct i

n D

evel

opm

ent

Acu

med

DeP

uy

Synt

hes

Stry

ker

Smith

&

Nep

hew

Shoulder

Clavicle/Scapula

Supe

rior C

lavi

cle

Plat

es

Ant

erio

r Cla

vicl

e Pl

ates

Hoo

k Pl

ates

Scap

ula

Bor

der P

late

s

Gle

noid

Pla

tes

Acr

omio

n Pl

ates

Cla

vicl

e Sc

rew

s/Pi

ns

Humerus

Prox

imal

Hum

eral

Nai

ls

Prox

imal

Hum

eral

Pla

tes

Mid

shaf

t Pla

tes

Elbow

Distal Humerus

90

/90

Pla

tes

Para

llel P

late

s

Exte

rnal

Fix

atio

n

Proximal Ulna

Ole

cran

on P

late

s

Cor

onoi

d Pl

ates

Prox

imal

Uln

a N

ails

Radial Head

Radi

al H

ead

Plat

es

Radi

al H

ead

Repl

acem

ent,

Shor

t Ste

m

Radi

al H

ead

Repl

acem

ent,

Long

Ste

m

Wrist

Midshaft Forearm

Uln

a Pl

ates

Ana

tom

ic M

idsh

aft V

olar

Ra

dius

Pla

tes

Dor

sola

tera

l Mid

shaf

t Ra

dius

Pla

tes

Uln

a N

ails

Radi

us N

ails

Distal Ulna

Dis

tal U

lna

Plat

es

Uln

ar S

hort

enin

g Pl

ates

Distal Radius

Vol

ar D

ista

l Rad

ius

Plat

es

Dor

sal D

ista

l Rad

ius

Plat

es

Radi

al S

tylo

id P

late

Dor

sal R

im P

late

s

Dor

sal L

unat

e Pl

ates

Vol

ar L

unat

e Pl

ates

Wris

t Spa

nnin

g Pl

ates

Exte

rnal

Fix

atio

n

Hand

Carpal

Wris

t Fus

ion

Niti

nol S

tapl

es

Phalangeal & Metacarpal

Han

d Fr

actu

re P

late

s

MC

P Fu

sion

Pla

tes

Exte

rnal

Fix

atio

n

Spec

ialty

Han

d Pl

ates

Screws

Headless

Con

tinuo

us C

ompr

essi

on

Diff

eren

tial P

itch

Headed

Part

ial T

hrea

d

Full

Thre

ad

Page 16: Product Overview - Acumed€¦ · Product Overview. Acumed ® Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation

Acumed Headquarters5885 NE Cornelius Pass RoadHillsboro, OR 97124

Office: +1.888.627.9957Office: +1.503.627.9957 Fax: +1.503.520.9618 www.acumed.net

HNW40-07-F | Effective: 2018/09 | © 2018 Acumed® LLC

These materials contain information about products that may or may not be available in any particular country or may be available under different trademarks in different countries. The products may be approved or cleared by governmental regulatory organizations for sale or use with different indications or restrictions in different countries. Products may not be approved for use in all countries. Nothing contained on these materials should be construed as a promotion or solicitation for any product or for the use of any product in a particular way which is not authorized under the laws and regulations of the country where the reader is located. Specific questions physicians may have about the availability and use of the products described on these materials should be directed to their particular local sales representative. Specific questions patients may have about the use of the products described in these materials or the appropriateness for their own conditions should be directed to their own physician.

Acumed® and Acutrak 2® are registered trademarks of Acumed LLC

Competitor Data Sources

DePuy Synthes website https://www.depuysynthes.com/

Stryker website https://www.stryker.com/us/en/index.html

Smith & Nephew website https://www.smith-nephew.com/

All websites accessed on February 1, 2018


Recommended