+ All Categories
Home > Documents > Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable...

Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable...

Date post: 11-Jul-2020
Category:
Upload: others
View: 16 times
Download: 1 times
Share this document with a friend
8
ETAP is the most comprehensive electrical engineering software solution for the design, simulation, operation, and automation of generation, transmission, distribution, and industrial power systems. ETAP is developed under an established quality assurance program and is used worldwide as a high impact software. ETAP is completely localized in six languages with translated output reports in seven languages. As a fully integrated enterprise solution, ETAP extends to a Real-Time Power Management System to monitor, control, automate, simulate, and optimize the operation of power systems. Product Overview Enterprise Software Solution for Electrical Power Systems
Transcript
Page 1: Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable Sizing Ampacity & Sizing • IEEE 399 Standard • NFPA 70 - National Electric Code

ETAPisthemost

comprehensiveelectricalengineering

softwaresolutionforthedesign,simulation,

operation,andautomationofgeneration,

transmission,distribution,andindustrialpower

systems.

ETAPisdevelopedunderanestablishedquality

assuranceprogramandisusedworldwideas

ahighimpactsoftware.ETAPiscompletely

localizedinsixlanguageswithtranslatedoutput

reportsinsevenlanguages.

Asafullyintegratedenterprisesolution,ETAP

extendstoaReal-TimePowerManagement

Systemtomonitor,control,automate,simulate,

andoptimizetheoperationofpowersystems.

ProductOverview

Enterprise Software Solutionfor Electrical Power Systems

Page 2: Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable Sizing Ampacity & Sizing • IEEE 399 Standard • NFPA 70 - National Electric Code

Network AnalysisShort Circuit - ANSI / IEEE•ANSI/IEEEC37Standards•IEEE141&399Standards•UL®489Standard•Integrateswithprotectivedevicecoordination•Automaticdeviceevaluationfor3-phase,1-phase,&panelsystems

•GeneratorCBevaluation•Phase-shiftingtransformer•Loadterminalshortcircuitcalculation

Short Circuit - IEC•IEC60909,60282,60781,&60947Standards•Transientfaultanalysis-IEC61363Standard•Integrateswithprotectivedevicecoordination•Automaticdeviceevaluationfor3-phase,1-phase,&panelsystems

•User-definablevoltagecfactor•Loadterminalshortcircuitcalculation

Load Flow•Powerflow•Demandload•Voltagedrop•Powerfactorcorrection•Automaticdeviceevaluation•Automatictemperaturecorrection•2W&3WtransformerLTC/regulatoractions•Real&reactivepowerlosses•Extensiveviolationalerts•Multi-reportResultAnalyzer•Auto-Runloadflowbasedonsystemchanges•AdaptiveNewton-Raphsonmethod•Fastconvergenceforsystemswithnegligibleimpedance

•Handlingoftransmissionseriescompensation

Motor Acceleration•Dynamicmotoracceleration•Voltageflicker•Motor&loaddynamicmodels•Staticmotorstarting•Multi-sequencestarting•Conventionalstartingdevices•Softstarterdevices•VFDfrequencycontrolmotorstarting•Load&generationtransitioning•MotorOperatedValve(MOV)simulation•Comprehensivealarm&warning•Startmotorindividuallyorbasedongroups

Modular

Arc FlashAC Arc Flash•IEEE15842002&2004Standards•NFPA®70E2000,2004,&2009Standards•CSAZ4622008Standard•ASTMD120-02aStandard•OSHA29CFR1910Standard•NationalElectricCode®(NEC)110.6•NationalElectricSafetyCode®(NESC)•Embeddedshortcircuit&devicecoordination•3&1-PhaseArcFlashSequence-of-Operation•Graphicaldisplayofdevicetripsequence•Automaticverificationofdeviceduty•User-definedincidentenergycorrectionfactor•CurrentLimitingFuse(CLF)modeling•IncidentEnergyplots•LVtransformerarcflashlimit•Maintenancemodeswitch•Relayactions(49,50,51,67,79,87)•Panels&single-phasesystems•Multi-reportResultAnalyzer•Labels,workpermits,&datasheets

DC Arc Flash•MaximumPowerMethod•Stokes&OppenlanderMethod•PaukertMethod•Determineincidentenergy•Assessarcflashprotectionboundary•ArcFlashViewer•Multi-reportResultAnalyzer•Labelsandworkpermits

Panel SystemsPanel ANSI & IEC•Intelligentpaneldesign&analysis•3-phase(3&4Wire)panels•1-phase(2&3Wire)panels•1-phase(A,B,C,AB,BC,CA,&3Wire)panels•ANSI&IECStandards•NationalElectricCodeloadfactors•Loadflowwithgraphicalperphasedisplay•Automaticdevicedutyevaluation&alerts•Automaticupdatingofupstreampanels•ExportpanelschedulestoMicrosoftExcel•Panelwithinternal&externalfeeders&loads

Protective DevicesCoordination & Selectivity•AC&DCcoordination•Graphicallyadjustabledevicesettings•Extensivedevicelibrary(verified&validated)•Embeddedshortcircuitanalysis•Embeddedmotoraccelerationanalysis•Multi-axistimecurrentcurves•Comprehensiveplotoptions•Adjustablemagnifying-glasszoomview•Timedifferencecalculator•Multi-function/levelrelays•Devicesettingreports•Automaticdetectionofprotectionzones•Protection&coordinationzoneviewer

Sequence-of-Operation•Viewdeviceoperationsequencegraphically•Devicefailure&backupoperation•Sequenceviewer•Normalized(shifted)curves•Currentsummation•Relayactions(27,49,50,51,51V,59,67,79,87)

Relay Test Set Interface•Interfaceswithtesting&maintenancedatabase•Exportshortcircuit&protectiverelaysettings•Plotdevicesteady-stateresponse•ComparerelayresponsewithOEMdata•Displayrelayactualtransientresponse•Analyzerelayfalsetrips&mis-operation•ExporttoCOMTRADEformat

User-Defined Dynamic Model•Fullgraphicalmodelbuilder•Libraryofpre-builtmodels•Integratedwithtransientstabilitymodels•Widevarietyofblocksforbuildingmodels•Import&ExportSimulink®models•Variousmodeltestingmethods•Real-timecompiling&linkingofmodel•AutomaticUDMlinkstocomponents•Compile&testdirectlyfromtheUDMbuilder

Page 3: Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable Sizing Ampacity & Sizing • IEEE 399 Standard • NFPA 70 - National Electric Code

Intuitive

Cable SizingAmpacity & Sizing•IEEE399Standard•NFPA70-NationalElectricCode•ICEAP54Standard•IEC60364-5-52,60364-4-43Standards•BS7671Standard•Ampacity/CurrentCarryingCapacityCalculator•Sizingbasedonampacity,voltagedrop,shortcircuit,harmonics,&overloadprotection

•Maximumoraverageoperatingcurrent•Armor&Sheaththermalcalculation•GroundingconductorselectionbasedonNEC•CableLibrarywithneutral,grounding/protectiveearthing(PE)conductor

•Addauxiliaryneutral&PEconductors•Optimal&alternativesizes•ModelForms:BS&user-definable•ReportsinCrystalReports&Excel

Protective Earthing (PE) Conductor Sizing•IEC60364-5-54Standard•BS7671Standard•PEthermalrequirements&sizing•User-definedfaultcurrent&clearingtime•ReportsinCrystalReports&Excel•Considerleakagecurrent

Electric Shock Protection•IEC60364-4-41Standard•BS7671Standard•EN50122Standard•TN-C,TN-S,TN-C-S,TT,&ITEarthingtypes•Electricshockrequirements•Loopimpedance&currentcalculation•Touchvoltagecalculation&evaluation•ConsiderresistancetoGround/Earth•GFCI/RCCBprotection•ReportsinCrystalReports&Excel

Parameter Estimation•Estimateinductionmachineequivalentcircuitparametersbasedonreadilyavailablemanufacturerdata

•Single-cagemodels•Rotordeep-bareffects

Renewable EnergyWind Turbine Generator•Modelunlimitedwindturbinegenerators•Detailedmodelingofturbinedynamics,aerodynamics,&powercoefficients

•DFIGwithpitch&convertercontroller•Simulatewinddisturbancelikeramp&gust•Individualorzone-baseddisturbances•WECCwindturbinemodels•WTGmanufacturer/modellibrary

Photovoltaic Array•Solarfarmmodeling•Solarirradiancebasedonlocation&time•Performanceadjustmentcoefficients•AC&DCSystemAnalysis•Inverterdynamicmodeling&operationmodes•MaximumPeakPowerTracking(MPPT)•Constantcurrentsourcemodeling•ModelPVsystemswithindividualpanels•ModelDCcables&combinerboxes•ExtensiveManufacturer/Modellibrary•P-V&I-Vcurves

Cable SystemsUnderground Thermal Analysis•Neher-McGrathMethod•IEC60287Standard•Steady-statetemperature•Ampacityoptimization•Automaticcablesizing•Transienttemperature•Intelligentrule-basedalignment&spacingtools•Automaticconduitdistribution&spacing•Uniform&non-uniformconduitarrangements•Custom,NEC,orIEEErule-basedspacing•Wizardforcreatingraceways

Cable Pulling•Integratedwithone-linediagramcables•Integratedwithundergroundracewayscables•Pullmultiplecables•Completelyflexiblepullgeometry•FullETAPcablelibraryintegration•Display3-Dpullingpathgeometry

Dynamics & TransientsTransient Stability•Completesynchronous&inductionmachinemodels•Comprehensiveexcitationsystemmodels•Comprehensivegovernor-turbinemodels•PowerSystemStabilizer(PSS)models•GE,Westinghouse,&Solargasturbines•User-definedDynamicModels(UDM)•Unlimitedsequenceofevents&actions•Typical&commondisturbances&operations•Automaticactionsbasedonrelaysettings•Short-time&long-timesimulation•Variabletotalsimulationtime&simulationstep•3-phase&line-to-groundfaultactions•Auto-synccheckaction•EmbeddedNewton-Raphsoninitialloadflow•VFD/VSDdynamicmodeling•LumpedLoaduser-defineddynamicmodeling•UPSparalleloperationmodeling•PVArraysourcemodeling•Invertersourcemodeling

Generator Start-Up•Cold-stategeneratorstarting•Loadgeneratorspriortosynchronousspeed•Frequency-dependentmachinemodels•Frequency-dependentnetworkmodels•AnexpansiontotheTransientStabilitymodule•User-defineddynamicmodelinterface

TransformerMVA Sizing•Sizingbasedonconnectedoroperatingload•ANSI&IECstandardtypes,classes,&ratings•Considersambienttemperature,altitude,loadgrowth,&loadfactors

•MVASizingbasedoncoolingstages

Tap Optimization•ANSI/IEEEC57.116Standard•Optimizeunittransformerturnsratio•Considerssystemvoltagevariation•Considersgenerationstationauxiliaryload•Generatorreactivecapacityvs.voltageplots

Page 4: Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable Sizing Ampacity & Sizing • IEEE 399 Standard • NFPA 70 - National Electric Code

Integrated

Power QualityHarmonic Load Flow•IEEE519Standard•Harmonicsspectrumupto250thorder•Automaticdistortionevaluation(THD&IHD)•Telephoneinfluencefactors(TIF&I*T)•Calculate&reportI*TB(Balanced)&I*TR(Residual)

•VFDharmonicmodeling•UPSACinput&outputmodelingforharmonicorders

•PVArraymodelingforharmonicorders•Automaticalertsofviolations•Harmonicsourceslibrary•EmbeddedAdaptiveNewton-RaphsonMethod•EmbeddedAcceleratedGauss-SeidelMethod

Interharmonics•Interharmonicmodeling&simulation•Performvoltageflickerlimitationstudies•InterharmonicdistortionindicescalculationbasedonIEC61000-4-7

•Adjustableharmoniccurrentbase•Automaticharmonicspectrumgeneration•Automaticinterharmonicfrequencygeneration

Frequency Scan•User-definablefrequencyrange•Resonanceconditionidentification&alerting•User-customizableplots

Harmonic Filters•Filterdesign&sizing•Single-tuned,high-pass,&band-passfilters•Automaticfilteroverloadingalert•Interharmonicfiltermodeling

Control SystemsDC Control Systems Diagram•Simulationofoperationsequence•Pickup&dropoutvoltagecalculation•Automaticalerts•Burden&inrushmodes•Controlledcontacts•Integratedwithbatterydischargecalculation•Integratedwithone-linediagram•Stateenginewithautomatic&step-by-stepsequence-of-operationofcontrolrelays,switchingactions,etc.

DataX PlusMicrosoft® Excel Interface•Bi-directionalExceldataexchange(Open&FixedFormats)

•MapExcelworksheetstoETAPelements•SynchronizedatatoETAPprojects•Performconsistencychecksduringdataexchange

•SubstitutemissinginformationwithETAPdefaults&librarydata

Project Merge•ParallelETAPprojectdevelopment•MergeBase&RevisionData•MergeTCCsViews•Multi-usermanagementofprojectmerge

SmartPlant® Electrical Interface•Bi-directionaldataexchange•MapattributesofSPELwithETAPelements•Databasemappingviagraphicuserinterface

e-DPP® Interface•Mapattributesofe-DPPtoETAPelements•Synchronizee-DPPdatatoETAPprojects•Databasemappingviagraphicuserinterface

DC SystemsLoad Flow •IEEE946Standard•IntegratedAC&DCsystems•EmbeddedNewton-RaphsonMethod•Voltagedrop•Powerlosses•Batteryauto-activation•Charger/UPScurrentlimit•Charger/UPSmodeauto-switching•DCconvertermodeling•Motormodelauto-switching

Short Circuit•IEEE946Standard•IntegratedAC&DCsystems•Totalbus&branchcontributionfaultcurrents•Faultcurrentrisingtime•BatterymodelingperANSI/IECStandard•ChargermodelingperANSI/IECStandard

Battery Discharge & Sizing•IEEE308,485,&946Standards•IntegratedAC,DC,&ControlSystemDiagram•Batterydischargesimulation•Batterysizing•DischargeviaDCloadflowordutycyclesummation

•Voltagedrop&lossconsideration•Class1EDCpower&controlsystemmodels•Simulationofcontrolsystemwithbatterydischargevoltage

•Dutycyclediversityfactor•Loadmodeltypeperoperatingcharacteristics•Batterydutycyclecalculatedfromindividualloads

•Optionsforbattery&loaddutycycle1minutespan

•Multipleuserselectedoptionsforbatterycharacteristicinterpolation

•Multiplediversity&correctionfactors•BatterysizingreportinIEEE485Standardformat

•Plotbatterycapacity,voltage,&current•Plotbusvoltage&load&branchflow•Detailedbatterylibrary

Page 5: Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable Sizing Ampacity & Sizing • IEEE 399 Standard • NFPA 70 - National Electric Code

Distribution SystemsUnbalanced Load Flow•Unbalancedpowerflow•Single-phase&unbalanced3-phasemodeling•Unbalanced&nonlinearloadmodeling•Open-deltatransformermodeling•Center-taptransformermodeling•Three1-phasetransformermodeling•Isolatedsub-systemswithvoltage-controlsourcemodeling

•Isolated1-phasesource&systemmodeling•Seriesfaultoropenphaseconditionmodeling•Phase&sequencevoltage,current,&power•Voltage&currentunbalancefactors•Transmissionlinecoupling•Automaticdeviceevaluation•Reportvoltage&powerinmulti-units

Optimal Power Flow•Solvemultipleobjectivessimultaneously•Interiorpointmethodwithbarrierfunctions•Minimizepowerlosses•Activepoweroptimization•Reactivepoweroptimization•Optimaldispatch

Optimal Capacitor Placement•Optimallocation&banksize•Minimizeinstallation&operationcosts•Individualsourceoraverageenergycost•Voltage&powerfactorobjectives•Minimum,maximum,&averageloading•Branchcapacityrelease&costsavings•Reviewcapacitorimpactonthesystem•Capacitorcontrolmethod•Flexibleconstraints

Reliability Assessment•Systemreliability•Customerorientedindices•Energy(cost)indices•Sensitivityanalysis•Single&doublecontingency

Single-Phase Distribution•ANSI&IECStandards•Loadflowwithgraphicalperphasedisplay•Voltagedrop&powerlosses•Voltage&currentunbalancefactors•Automaticdevicedutyevaluation&alerts

Geographic Information System

GIS Map•ViewGISmapsinETAP•DisplayanalysisresultsonGISmaps•SynchronizeGISdatatoETAPprojects•Usegraphicaluserinterfacefordatamapping•Controlmodification&accept/rejectactions•Checkconsistencyfordatasynchronization•UtilizeGISmaptools•GIShandlingof1-phasesystems

Ground Grid SystemsFinite Element Method•3-Dplotsforstep,touch,&absolutepotentials•3-Dirregularconfigurations•3-Dgraphicalinterfaceviews•Rods&conductorsinanydirection•Graphicaldisplayofoverlimits

IEEE 80 & 665 Standards•Conductor&rodoptimization•3-Dgraphicalinterfaceviews

Transmission LineLine Constants•Conductor&groundwirelibraries•Built-inconfigurations:horizontal,vertical,etc.•Generalconfiguration:X,Y,&Zcoordinates•Multi-linemutualcoupling•Phase&sequenceimpedancematrix•Transposed&un-transposedlines•Short&longlinemodels•Multiplelayersoilmodel•Calculatedoruser-definedimpedances

Line Ampacity•Conductorampacityvs.temperature•IEEE738Standard•Determinemaximumoperatingtemperatureforvariousloadingconditions

•Deratedampacitybasedontemperaturelimit•Considerweather,solarheat,&geographicallocation

Sag & Tension •Sag/tensionvs.temperature•Multiplespansbetweendead-endstructures•Levelspansofunequallength•Solvespansofunequallengthondifferenthorizontalplanes

•Includeeffectsofwind,temperature,&kfactor

HVDC Transmission Link•Detailedrectifier&convertermodeling•CompositeAC/DC&DC/ACsystems•Built-incontrolschemes•Inclusivetransformermodel•Automaticharmonicspectrumcalculation•Easy-to-useintegratedmodel

Comprehensive

ISO 9001:200810 CFR 50 Appendix B 10 CFR 21ANSI/ASME N45.2ASME NQA-1ANSI / IEEE 730.1CAN / CSA-Q396.1.2ANSI N45.22

ETAP Quality AssuranceETAP's quality assurance is specifically dedicated to meeting the requirements of:

ETAPisVerifiedandValidated(V&V)againstfieldresults,realsystemmeasurements,establishedprograms,andhandcalculationsinordertoensureitstechnicalaccuracy.EachreleaseofETAPundergoesacompleteV&Vprocessusingthousandsoftestcasesforeachandeverycalculationmoduleandlibrarydata.

ETAP is a high impact software qualified for use within nuclear, military and mission critical facilities and operations.

Certificate Registration #10002889 QM08

Page 6: Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable Sizing Ampacity & Sizing • IEEE 399 Standard • NFPA 70 - National Electric Code

Base PackageBase Package

ETAPBasePackageisasetofcoretools,embeddedanalysismodules,andengineeringlibrariesthatallowyoutocreate,configure,customize,andmanageyoursystemmodel.Coretoolsallowyoutoquicklyandeasilybuild3-phaseand1-phaseACandDCnetworkone-linediagramswithunlimitedbusesandelementsincludingdetailedinstrumentationandgroundingcomponents.Engineeringlibrariesprovidecompleteverifiedandvalidateddatabasedonequipmentmanufacturers'publisheddata.

Cable Manager•Batchcablemanagement•Customizablecablereports•Multi-cablesizing&shockprotectionevaluation•Intelligentsearch/filtering

Data Manager •View/editBase&RevisionData•Viewequipmentpropertiesforindividualfields•Viewequipmentstate&Service•Viewabsolutevalueordifferences•Display&filterdatabasedonstudytype•Graphicaldatamanagement&mergeperindividualequipment

Theme Manager•Displaycolorcodingbasedon:-Standard -Voltagelevel-Area-Grounding(Solid,Low-Z,High-Z,Ungrounded)-Earthing(TT,TN,IT,NEC)

•Displayfaultedbusesbysymbolorcolor

Multi-Dimensional Database•Orthogonalmulti-dimensiondatabase•Unlimitedindependentgraphicalviews•Unlimitedstatusconfigurations•Unlimitedpropertyrevisions•Multipleloading&generationconditions•Lock&unlockelementproperties•10Statestotrackequipmentconditions•Utilizereal-timeoperatingdata•Unlimitedstudysolutions•ODBC–MSAccess,SQLServerconnectivity•Dumpsterwithunlimitedcells:copy&paste•Useraccesssecuritywithpasswordprotection•Edited-by&checked-bywithdatestamping•Mergeprojectfilesviaclipboard

Embedded Analysis Modules

One-Line Diagram•Built-inintelligentgraphics•Automaticequipmentconnectionmode•Networknesting•Integrated1-phase,3-phase,&DCsystems•IntegratedAC,DC,&groundingsystems•Multiplegenerators&gridconnections•Displayresultsonone-linediagrams•Customizablefonttypes,styles,&colors•Customizabledisplayofratings&results•Graphicaldisplayofequipmentgrounding•Graphicaldisplayofoverstresseddevices&alerts

•Hide&showprotectivedevices&groundingelements

•Thememanager•One-linetemplates•Propagationofnominal&ratedvoltage•Propagationofphaseconnection•Automaticdisplayofenergized&de-energizedelementsusingdynamiccontinuitycheck

•Textboxeditorwithdynamiclinktoproperties•OLEobject&ActiveXcontrolintegration•Intelligenttextbox&hyperlinkbookmarks•CustomizableoutputreportsviaCrystalReports

•Batchprintingwithview-dependentprintersettings

•User-friendlyplotting•Keywordbasedelementsearch

One-Line Diagram Templates•Create&utilizeunlimitedone-linetemplates•SharetemplatescreatedbyotherETAPengineers

•UsedefaultprojectIDortemplateID•Usepropertiesfromthedefaultprojectortemplates

•Instantpreviewoftemplates

System Elements•UnlimitedAC&DCelements•1-phase(2&3Wire),2-phase(2&3Wire),3-phase(3&4Wire)

•Unlimitedbuses:licensedependentatrun-time•Nestedviews(compositenetworks&MCC)•Powergrid•Synchronous&inductiongenerators•Photovoltaicarray(PVInterconnectionStudy)•DCPhotovoltaicarray•WindTurbineGenerator•MOV,synchronous,&inductionmotors•Exciters,governors,&stabilizers•Voltage&frequencydependentlumpedload•Cable,line,reactor,&impedancebranches•2W&3Wtransformerswithvoltageregulators•2W&3Wtransformerswithburieddeltawinding•Open-Deltatransformer•Remoteconnectors•Harmonicfilter•StaticVarCompensator•Instrumenttransformers(CT&VT)•Protectivedevices&meters•Single&doublethrowswitches•Groundingswitch•Busduct•Batteries,DCmotors,DCloads&branches•Chargers•Inverters•UPS•DCconverter•VariableFrequency/SpeedDrive(VFD/VSD)•ANSI,IEC,&user-definedsymbols

Switching Device Interlock Enforcer•Autoenforcementofswitchinginterlocklogics•Automatic‘pre’&‘post’switchinglogicverification•Interlockbasedoncircuitbreakerpositionsormeterreadings

•Automaticinterlockconflictchecking•Abilitytomodelcascadeswitchingcontrol•Activemonitoringofswitchinginterlockviolations•Switchingplanvalidation

Configuration Manager•Tabulate&controldifferentstatusconfigurations•Comparesource,load,&switchingdevicestatus•Flagchangeddatawithcheckercapability•Copy,merge,export,import,&print

• Cable Constants

• Transmission Line Constants

• Cable Ampacity

• Cable Sizing

• Cable Manager

Page 7: Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable Sizing Ampacity & Sizing • IEEE 399 Standard • NFPA 70 - National Electric Code

Network Simulation•Unlimitedbuses(licensedependent)&elements•Looped&radialsystems•Automaticerrorchecking•Userinterfaceforallnetworkanalysismodules•CustomizableETAPpreferenceproperties•Multi-leveluseraccessmanagement

Built-In Calculators•MVA,MW,Mvar,kV,Amp,&PFconversion•Motornameplate&dynamicparameterdata•Generationnameplate•Powergridshortcircuitimpedances•Motor&generationinertia

Output Report Comparator•Built-inoutputreportcomparisontool•Comparehundredsofstudyreportsinoneaction•Verifystudyresultsagainstbenchmarkreports

Project Management•Managestudieswithscenarios&macros•Recordscenariosbasedonstudysettings•Macro-controlledscenarioexecution

Data Exchange (DataX) Base•LegacyprogramconversiontoETAP•Automaticone-linecreation•Protectivedevicelibrarymapping•Convertusingnativefileformats•Built-inconversionsforSKM®Dapper®&Captor™,PSS®E,EasyPower®&others

•WMF/EMF/DXF/PDFexporting•ImportRAW/IEEE/CSVfiles•ExporttoAutoCAD®usingDXFformat•ImportgroundgridplansfromAutoCAD•LoadTicketforinductionmachines

Download a Free Demo at etap.com

Base PackageBase Package

BasePackageincludesanintelligentone-linediagram,elementeditors,verifiedandvalidatedengineeringdevicelibraries,configurationmanager,reportmanager,projectandstudywizards,multi-dimensionaldatabase,thememanager,dataexchange,anduseraccessmanagement.Embeddedanalysismodules,suchasCableAmpacity,CableSizing,andTransmissionLineConstants,provideintegratedaswellasstand-alonecapabilitiestodesign,analyze,andsizeequipment.

Libraries•Comprehensivelibrary(over100,000devices)•ANSI&IECdeviceslibraries•Verified&Validated(V&V)librarydata•V&Vlockeddata•Add,copy,merge,&deletecapabilities•User-defined&controlledlibraries•User-accesscontrol&security•Edited-by&checked-bywithdatestamping•User-controlledlibrarymerge

Report Manager•Customizableoutputreports&plots•Input,results,alerts,&summaryreports•ReportsviaCrystalReportsviewer•PDF,Microsoft®Word,Access,&Excelreports•ElementID&textsearchcapability•Multi-languageReport

License Manager•Stand-Alone•ConcurrentUserLAN&WAN•Networklicensecheckout•Licenseborrowingmanager•Flexiblelicenseborrowingduration•LicenseManagerconfigurationwizardutility

Multiple Language Support•Interface&HelpFileinsixlanguages•Outputreportsinsevenlanguages

Cable

CableFireCoatingProtection

CableFireStopProtection

CableFireWrapProtection

TransmissionLine

LineGroundConductor

MotorNameplate

MotorCKTModel

MotorCharacteristicModel

MotorLoadModel

WindTurbineGenerator

PhotovoltaicPanel

SolarPanel

Fuse

RecloserHydraulic

RecloserElectronicController

HVCircuitBreaker

LVCircuitBreaker

SolidStateTrip

ThermalMagnetic

Electro-Magnetic

MotorCircuitProtector

OverloadHeater

Harmonic

InterruptionCost

Reliability

Battery

ControlContact

ControlRelay

ControlSolenoid

GFI/RCD

Libraries

English

Chinese

Japanese

Russian

Spanish

Portuguese

German

OutputReportsInEveryRelease

LocalizedRelease

Page 8: Product Overview - fr.eneroptim.rofr.eneroptim.ro/download/etap/overview.pdf · Intuitive Cable Sizing Ampacity & Sizing • IEEE 399 Standard • NFPA 70 - National Electric Code

Intelligent Load Shedding

Load Preservation•Steady-state&transientresponse•Optimalloadpreservation•Fastresponsetime•Reliableoperation•Minimumloadshedding•Proactivecontingencyanalysis•Systemislandinglogic•VFDloadreductioncontrol

System Restoration•Restartinhibition•Logicalloadsequencer•Load/sourcerestorationpriority

Load Shedding Validation•Automaticgenerationoftransientstudycases

•Confirmloadsheddingactions•SimulateILSrecommendation•Integratedstabilityknowledgebase

IntelligentSubstation

Substation Automation•Flexibleautomation•Programmablelogiceditor•Onlinecontrol•Remotecontrol-enable&disablecommands

•Controlinhibitionbasedonsystemoperationalconstraints

Switching Management•Switchingsequencemanagement

•Safety&securityprocedures•Interlocklogicevaluator•Switchingplanvalidation•Controlinhibitionbasedonswitchingoperations

•Safetygroundswitch•Pre-switch&post-actioninterlock•Enforcedinterlocklogicinsimulationmode

•IntegratedoperationwithSwitchingManagementSystem

•Supervisorycontrolforreal-timeswitchingoperation

Load Management•Demand-sidemanagement•Time-of-useloadshifting•Intelligentloadmanagement

Energy ManagementSystem

Automatic Generation Control•Multi-areacontrol•Loadfrequencycontrol•MW&MVARsharing•NERCperformancestandard

Economic Dispatch•Minimizefuelcosts•Optimizeenergycosts•Fastsolution•Robustalgorithms

Supervisory Control•Systemoptimization•Supervisory&advisorycontrolsystem

•Optimalpowerflow•Programmablelogiceditor

Interchange Scheduling•Tariffanalyzer•Ratestructurebuilder•Transactionscheduling•Transactioncontract•Transactionreports•Fuelcostschedulereports

Reserve Management•Operatingreserveanalysis•Reservecapacitymonitoring•Notificationofinadequatereserve•Predictoperatingreserve

Information Storage & Retrieval•SQLServer-baseddataarchiving•Energy,power&non-electricaldatatracking

•Automaticdatahandling•ExporttoMSExcel•CustomizableReports

Monitoring & Predictive Simulation

Advanced Monitoring•NetworkTopologyBuilder&Processor•Intelligentgraphicaluserinterface•Stateestimator&loaddistributor•Process&performancemonitoring•Alarm&notificationmanagement•Generationreservemonitoring•Multi-statebreakermonitoring&control•Thinclientbasedmonitoring&control•HumanMachineInterface(HMI)templatelibrary

•Web-basedcustomizableHMI

Energy Accounting•Energytariffbuilder•Customizablereports•Real-timeenergycosttracker•Cost&consumptionsummary

Real-Time Simulation•Simulatecircuitbreakeroperation•Identifypotentialoperatingproblems•Simulatemotorstarting&loadchange•Predictoperatingtimeofprotectivedevices

•Predictsystemresponsebasedonoperatoractions

•Perform“WhatIf”operatingscenarios•Web-basedsimulation&alerts•Simulatereal-time&archiveddata•Operatorassistance&training

Event Playback•Replayarchivedhistoriandata•Investigatecause&effect•Explorealternativeactions•Replay“WhatIf”scenarios•Playbackofeventviews•Historicalalarmdatabase

Load Forecasting•Adaptivebusloadforecasting•Real-timetrending•Loadprofilelibrary•Forecastingscenarioarchiving

(800) 477-ETAP • (949) 900-1000

ETAP Real-TimeETAP Real-Time

• Power Management System• Energy Management System• Generation Management System• Distribution Mangement System• Intelligent Load Shedding• Smart Grid & Microgrid Solutions

Real-Time Solutions

B8-1013

© 2012 ETAP / Operation Technology, Inc. All rights reserved. Certain names and/or logos used in this document may constitute trademarks, service marks, or trade names of Operation Technology, Inc. Other brand and product names are trademarks of their respective holders.


Recommended