Temperature Transmitters, Alarm Units, Indicators, Signal Isolators, Configurations kits
• Complete range of Transmitters for in-head and DIN-rail mounting• App for wireless configuration and monitoring via NFC and Bluetooth • Complete range of Loop Powered Isolators and Isolation Transmitters• Alarm Units for monitoring of temperature and process signals• Selection of Loop Powered Indicators
PRODUCT OVERVIEW
Input: RTD, T/COutput: 4-20mAConfiguration: PC (via USB Interface)Accuracy: ±0.15% of Span
Basic Programmable 2-wire Transmitter
MINIPAQ-HLP/-LIPAQ C/R 202Programmable 2-wire Transmitter for Pt100 sensors
Input: RTDOutput: 4-20mAConfiguration: PC (via USB Interface)Accuracy: ±0.1% of SpanApprovals: ATEX & IECEx (IPAQ C202)
Analog Adjustable 2-wire Transmitter
Input: RTD or T/COutput: 4-20mAConfiguration: Solder pads, PotentiometersAccuracy: RTD ±0.15% of Span T/C ±0.5% of SpanApprovals: ATEX (APAQ-H)
APAQ-H/-LC
Input: RTD, T/C, Ω, mVOutput: 4-20mAConfiguration: PC (via USB Interface) App (via NFC or Bluetooth®)Accuracy: ±0.08% of SpanIsolation: 1500 VACApprovals: ATEX / IECEx / cFMus
Universal Programmable 2-wire Transmitter
IPAQ C/R 330
Input: RTD, T/C, Ω, mVOutput: 4-20 mA, HART®
Configuration: PC (via USB Interface) HART, DD, DTMAccuracy: ±0.05% of SpanIsolation: 1500 VACApprovals: ATEX / IECEx / SIL2
HART® Universal Dual-input 2-wire Transmitter
IPAQ C/R 520
Input: RTD, T/C, Ω, mVOutput: 4-20mA, HART®7Configuration: PC (via USB Interface) App (via NFC or Bluetooth®) HART, DD, DTMAccuracy: ±0.1% of SpanIsolation: 1500 VACApprovals: ATEX / IECEx / cFMus
HART® Universal 2-wire Transmitter
IPAQ C/R 530
Temperature transmitters
4-wire, High Isolation Temperature Transmitter
Input: RTD, T/C, Ω, mV, V, mAOutput: 0/4-20mA, 0/2-10VConfiguration: PC (via USB Interface)Accuracy: ±0.1% of SpanIsolation: 4000 VAC
IPAQ-4LAnalog Adjustable 3-wire Transmitter
Input: RTDOutput: 0-10 VConfiguration: Solder pads or PotentiometersAccuracy: ±0.15% of Span
APAQ-3HPT/-3LPT
Input: RTDOutput: 4-20 mAConfiguration: PC (via USB Interface)Accuracy: ±0.2% of Span Power supply: 7.5 to 32 VDCProcess connection: M12x1,4-pin
Analog, PC-configurable compact transmitter
IPAQ CT20
Input: RTDOutput: 4-20 mA, 0-10 V Measuring channels: 2 channelsConfiguration: PC (via USB Interface)Accuracy: ±0.03% of Span
Precision Transmitter for Absolute and Differential Temperature Measurement
DA576
Input: Potentiometer 0 – 100000 ΩOutput: 4-20 mAConfiguration: PC (via USB Interface)Accuracy: ±0.2% of Span
Analog 2-wire Transmitter for Potentiometer Input
DB537
Input: RTD, T/C, Ω, mVOutput: 4-20 mA / 20-4 mAConfiguration: PC (via USB Interface)Accuracy: ±0.1% of SpanIsolation: 1500 VACApprovals: ATEX
Universal 1-channel programmable 2-wire Transmitter
IPAQ-21L
Input: RTD, T/C, Ω, mVOutput: 4-20 mA / 20-4 mAConfiguration: PC (via USB Interface)Accuracy: ±0.1% of SpanIsolation: 1500 VACApprovals: ATEX
Universal 2-channels programmable 2-wire Transmitter
IPAQ-22L
OEM 202P/R/W
Input: Pt100, Pt1000Output: 4-20 mAConfiguration: PC (via USB Interface)Accuracy: ±0.1% of SpanPower supply: 5.0...32.0 VDC Customizable design to fit your needs
Digital temperaturetransmittersto be built in
Transmitter repeater for powering andisolation of 2-,3- and 4-wire transmittersType: ActiveSignal: Transmitter Isolation level: 3 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: 6 mm line
IsoPAQ-610
Isolation Transmitter for UnipolarmA/V Signals with Fixed RangesType: ActiveSignal: Transmitter Isolation level: 3 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: Compact line
IsoPAQ-131P
Signal Splitter/Repeater with double outputs for mA and V signalsType: ActiveSignal: mA/V Isolation level: 3 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: 6 mm line
IsoPAQ-632
High-performance isolation transmitterfor mA/V Signals with calibrated rangeselectionType: ActiveSignal: mA/V Isolation level: 3 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: 6 mm line
IsoPAQ-641Isolation transmitter for Bipolar andUnipolar mA/V signals with calibratedrange selectionType: ActiveSignal: mA/V Isolation level: 3 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: 6 mm line
IsoPAQ-661
1- & 2-channel Loop Powered Isolatorsfor separation of 0(4)-20 mA SignalsType: PassiveSignal: mA Isolation level: 3 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DC Housing: 6 mm line
IsoPAQ-611/-612
1- & 2-channel Loop PoweredIsolators for 0(4)-20 mA SignalsType: PassiveSignal: mAIsolation level: 2.5 kv, 50 HzAccuracy: ±0.15% FSHousing: Compact line
IsoPAQ-110L
Transmitter Repeater for Poweringand Isolation of 2-wire TransmittersType: ActiveSignal: Transmitter Isolation level: 2.5 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: Compact line
IsoPAQ-110R
Isolation Transmitter for Bipolar and Unipolar mA/V Signals with Fixed RangesType: ActiveSignal: mA/V Isolation level: 2.5 kv, 50 HzAccuracy: ±0.2% FSWorking Voltage: 600 VAC/DCHousing: Compact line
IsoPAQ-161P
Isolators and Isolation Transmitters
1- & 2-channel Loop Powered Isolatorsfor Separation of 0(4)-20 mA SignalsType: PassiveSignal: mA Isolation level: 3 kv, 50 HzAccuracy: ±0.1% FSHousing: Standard line
IsoPAQ-11L/-12L1- & 2-channel Loop Powered Isolatorsfor 0(4)-20 mA Signals with High Isolation and Protective SeparationType: PassiveSignal: mA Isolation level: 4 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: Standard line
IsoPAQ-21L/-22L1- & 2-channel Loop Powered Isolatorsfor 0(4)-20 mA Signals with High Isolation and Protective SeparationType: PassiveSignal: mA Isolation level: 4 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: Standard line
IsoPAQ-21L/-22LBasic Isolation Transmitter for Unipolar mA/V Signals with Calibrated Range SelectionType: ActiveSignal: mA/V Isolation level: 2.5 kv, 50 HzAccuracy: ±0.3% FSWorking Voltage: 600 VAC/DCHousing: Standard line
IsoPAQ-30P
High-performance Isolation Transmitter for Unipolar mA/V Signalswith Calibrated Range SelectionType: ActiveSignal: mA/V Isolation level: 4 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: Standard line
IsoPAQ-40PHigh-performance Isolation Transmitter for Unipolar mA/V Signals with Fixed RangesType: ActiveSignal: mA/V Isolation level: 4 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: Standard line
IsoPAQ-41PHigh-performance Isolation Transmitterfor Unipolar mA Signals with Fixed Range and Zero/Span Adjustment
Type: ActiveSignal: mA Isolation level: 4 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 600 VAC/DCHousing: Standard line
IsoPAQ-51P
High-performance Isolation Transmitterfor Bipolar and Unipolar mA/V Signals with Extensive Range Selection and Zero/Span AdjustmentType: ActiveSignal: mA/V Isolation level: 4 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 1000 VAC/DCHousing: Standard line
IsoPAQ-60PBasic Isolation Transmitter for Unipolar Shunt Voltages with Calibrated Range SelectionType: ActiveSignal: V Isolation level: 2.5 kv, 50 HzAccuracy: ±0.3% FSWorking Voltage: 600 VAC/DCHousing: Standard line
IsoPAQ-70SHigh-performance Isolation Transmitter for Bipolar and Unipolar Shunt Voltages with Extensive Range Selection and Zero/Span AdjustmentType: ActiveSignal: V Isolation level: 4 kv, 50 HzAccuracy: ±0.1% FSWorking Voltage: 1000 VAC/DCHousing: Standard line
IsoPAQ-80S
Loop Powered Heavy-duty LCD Field IndicatorMaterial: Aluminium Protection: IP 68 Digit size: 8.89 mm, backlight Mounting: Wall mount or 2” pipe clamp
LCD-H30
Loop Powered LCD Indicator for Field MountingMaterial: Plastic Protection: IP 65 Digit size: 17.8 mm Mounting: Rail, Wall mount or 2” pipe clamp
LCD-W11Loop Powered LED Indicator for Field MountingMaterial: Plastic Protection: IP 65 Digit size: 14.2 mm Mounting: Rail, Wall mount or 2” pipe clamp
LED-W11
Loop Powered & Ex-approvedLED Indicator for Gas Zone 1 & 2Material: Plastic Protection: IP 65 Digit size: 14.2 mm Mounting: Rail, Wall mount or 2” pipe clamp
LED-W11XLoop Powered LCD Indicator for In-head MountingMaterial: Aluminium Protection: IP 65 Digit size: 12 mm Mounting: Sensor
LCD-H20
Programmable 2-wire IsolationTransmitter for mA SignalsInput: mA Isolation level: 1500 VACAccuracy: ±0.1% of spanPower Supply: 7.5...36.0 VDC
IPAQ-L(mA)Isolation Transmitter for mA/V Signals with 2-wire Transmitter SupplyInput: mA, V Isolation level: 1500 VACAccuracy: ±0.15% of spanPower Supply: AC/DC versions
DA561Dual Channel Isolation Transmitterfor mA/V SignalsInput: mA, V Isolation level: 1500 VACAccuracy: ±0.15% of spanPower Supply: AC/DC versions
DA562
Isolation Transmitters with special features
Field housing and Indicators
Alarm Unit with Pt100 Input and 4-20 mA OutputInput: Pt100Typical Accuracy: ±0.1% of spanPower supply: AC: 230 VAC / 115 VAC DC: 19 to 60 VDCC
SR535Alarm Unit with Pt100 Inputand Double Relay OutputsInput: Pt100, Pt200, Pt500, Pt1000Typical Accuracy: ±0.2% of spanPower supply: 24 VAC/DC
SR335
Dual Channel Alarm Unit with mA/V Input and Double Relay OutputsInput: Current, VoltageNo. of channels: 2 channelsTypical Accuracy: ±0.1% of spanPower supply: AC: 230 VAC / 115 VAC DC: 19 to 60 VDCC
SR560
Alarm Unit with mA/V Input and Double Relay OutputsInput: Current, VoltageTypical Accuracy: ±0.2% of spanPower supply: 24 VAC/DC
SR360
4-channel Power Supply for 2-wire TransmittersVoltage: ~25 VDCCurrent limitation: ~35 mAMaximum ripple: 5 mV eff.Power supply: AC: 230 VAC / 115 VAC DC: 19 to 60 VDC
ME544
Ex-certified TransmitterConfiguration KitType: PC configuration Communication: USBGalvanic isolation: 1500 VACEx approval: ATEX, IECEx, cFMus
ICON-XConfiguration kit for wireless configuration and monitoringType: Wireless configuration Communication: Bluetooth®
Size: 71 x 28 x 24 mm
ICON-BT
Configuration kits & Software
Alarm units & Power Supply
INOR Connect Download the app INOR ConnectConSoft
Download the PC-software ConSoft at www.inor.com
ConSoft
© IN
OR 0
5/20
19 4
0076
2940
1 BR
Pro
duct
ove
rvie
w -R
01-e
n Su
bjec
t to
chan
ge w
ithou
t not
ice.
INOR product overview
• Temperature Transmitters
• Isolators & Isolation Transmitters
• Field Housing & Indicators
• Power Supply & Alarm Units
• Temperature Sensors
• Accessories
• Services
www.inor.com
Contact Head officeInor Process AB PO Box 9125SE-200 39 MalmöSwedenPhone: +46-(0)40-312560E-mail: [email protected]
Global partners and representativesThe current list of all INOR contacts and addresses can be found at:www.inor.com/partners