Description These single and double leaf doors are fitted into compartment walls to confine an outbreak of fire to the smallest area. They are designed to resist the intense heat applied to one side of the door without excessive distortion, and prevent the ignition of combustible materials in the adjoining area. Approval The manufacturing process of these doors is quality controlled at all stages in line with ISO 9001: 2000 Quality Standard and is independently audited by the LPCB. The door construction has been tested to BS.476 Part 8 at the Warrington Research Centre and obtained the following results: Stability - 240 minutes (test discontinued) Integrity - 240 minutes Insulation - 26 minutes (Certificate No. WRCSI-28908) Specification Leaf Construction 1.2 mm zintec coated sheet steel faces enclose a 40mm inert ceramic fibre insulated core with suitable 2mm steel stiffeners. Total leaf thickness = 43mm. The doors are delivered to site, in grey zinc chromate primer for immediate on-site painting by others. Frame Construction Each door leaf is pre-hung by 1.5 pairs of McGill heavy duty hinges, screwed to the leaf and welded to the 2.5 mm zintec coated pre-formed steel frame. The inherent 10 mm x 50 mm bottom cill member completing the 4 sided frame is designed for flush mounting on to the floor. 10 off 10 mm rawbolts are included for fixing around the door frame. Self-Closing Self-closing action is available if required, by suitable hydraulic overhead closers. On double leaf door sets, a leaf selector is fitted to ensure the doors are closed in the correct sequence. Optional Components Smoke detector operated release units Vision panels Panic bar systems Kick plates Magnetic contacts. product profile D100/D101 Fire Resistant Door 2/4 hour rated hinged double leaf door
Transcript
Page 1: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThese single and double leaf doors are fitted into compartment walls to confine an outbreak of fire to the

smallest area. They are designed to resist the intense heat applied to one side of the door without excessive

distortion, and prevent the ignition of combustible materials in the adjoining area.

ApprovalThe manufacturing process of these doors is

quality controlled at all stages in line with ISO

9001: 2000 Quality Standard and is

independently audited by the LPCB. The door

construction has been tested to BS.476 Part 8 at

the Warrington Research Centre and obtained

the following results:

Stability - 240 minutes (test discontinued)

Integrity - 240 minutes

Insulation - 26 minutes (Certificate No.

WRCSI-28908)

SpecificationLeaf Construction1.2 mm zintec coated sheet steel faces enclose a

40mm inert ceramic fibre insulated core with

suitable 2mm steel stiffeners. Total leaf

thickness = 43mm. The doors are delivered to

site, in grey zinc chromate primer for immediate on-site painting by others.

Frame ConstructionEach door leaf is pre-hung by 1.5 pairs of McGill heavy duty hinges, screwed to the leaf and welded to the 2.5

mm zintec coated pre-formed steel frame. The inherent 10 mm x 50 mm bottom cill member completing the 4

sided frame is designed for flush mounting on to the floor. 10 off 10 mm rawbolts are included for fixing

around the door frame.

Self-ClosingSelf-closing action is available if required, by suitable hydraulic overhead closers. On double leaf door sets, a

leaf selector is fitted to ensure the doors are closed in the correct sequence.

Optional ComponentsSmoke detector operated release units

Vision panels

Panic bar systems

Kick plates

Magnetic contacts.

product profileD100/D101 Fire Resistant Door

2/4 hour rated hinged double leaf door

Page 2: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

D100 Fire Resistant Door2/4 hour rated single leaf hinged door

Page 3: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

D101 Fire Resistant Door2/4 hour rated double leaf hinged door

Page 4: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThe S66 Daloc Fire Door has been designed to provide adequate means of escape for people evacuating a

building in the event of a fire. Typical applications include industrial premises, and multi-storey car parks.

ApprovalThis door is approved by SITAC as a class E60 fire door and the Swedish National Testing and Research Institute

(SP) monitor its manufacture. The protection distance to people being evacuated and combustible material

must be at least 1 metre from the door face.

SpecificationThe doorleaf has a rolled seam edge and consists of 1.2 mm

cold-rolled steel that is profiled, folded and welded

together with full steel internal stiffeners.

DoorleafThickness 54 mm

Finish Supplied primed in grey

Insulation Mineral wool

FrameStandard Frame 31 with fixed architrave on the

front face

Finish Supplied primed in the same grey as

the doorleaf

Insulation Fitted with mineral wool

Manufactured in 2 mm cold-rolled steel.

Several different types are available :• Architrave on the front face

• Architrave on both sides or without architrave

The frame can be fixed with screw fixings. For doors larger than 3 x 3 metres it is recommended that the door

is welded to a forged wrap-around profile.

ThresholdThe Daloc S66 door is supplied with a steel threshold bar, which can be cut away after installation if not required.

S66 Fire Doorproduct profile

Page 5: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S66 Fire Door

Standard IronmongeryLock Assa/Nemef

Ball-bearing hinge in primed steel. Internal reinforcement for door closer.

Optional ComponentsFitted supplementary lock

Vision panel

Rubber kick plate

Stainless steel kick plate

Flexible rubber wipe strip

Sealing strip in frame

Cut-out for electric striking plate

Cut-out for magnetic contact

Cut-out for bolt contact

Cut-out for cable lead cover

Ventilation grille (not fire rated)

Ventilation grille with shutter (not fire rated)

Door closer, not fitted

Double Leaf Door S662The door leaves and frame are manufactured in the same way as single door Daloc S661. The inactive leaf

is provided with a steel astragal strip and it is fitted as standard with a surface-mounted espagnolette on

the inner face. A hook bolt is fitted on the hinge edge and engages in the inactive leaf.

S661 30 x 30 2900 x 2925 2870 x 2910 3000 x 3000 360

S662 36 x 40 3500 x 3925 3470 x 3910 3600 x 4000 560

Max. size for 6000 x 4025 5970 x 4010 6100 x 4100 950fire rating E60

Reference Clear Opening Size Structural Opening Size Standard Width WeightW x H in mm W x H in mm Active Leaf in kg.

+ 20 + 10– 5 – 5

Page 6: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S66 Fire Door

Page 7: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S66 Fire Door

Page 8: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThe S60 Daloc Fire Door has been designed for areas where fire safety combined with strength, stability anddurability is a priority. Typical applications include basements, lofts industrial premises, multi-storey car parksand signal boxes, etc. When supplemented with burglar protection, the Daloc S60 performs excellently as anexternal security door.

ApprovalThis door is a CERTIFIRE approved fire door (Certificate- 247) tested to BS476 Part 22 to 240 minutes. The Dooralso meets the relevant requirements of BS5588. Doors with seals fitted to the frame have successfullycompleted panel smoke passage to BS476 Part 31-1. The S60 also has a sound reduction index of Rw 33dB,tested to SS-EN ISO 140-3:95.

SpecificationThe doorleaf has a rolled seam edge and consists of 1 mmgalvanised steel that is profiled, folded and glued together.Modern machinery and manufacturing methods mean thatthe completed doorleaf has a smooth, even surface.

DoorleafThickness 54 mmFinish Supplied primed in grey/plain galvanisedInsulation Mineral wool

FrameStandard Frame 21Finish Supplied primed in the same grey as the

door leaf or plain galvanisedInsulation Fitted with mineral wool

Manufactured in 1.5 mm cold-rolled type HSLA 350YP steel.

Several different types are available :• Architraves on the front face• Architraves on both sides• Without architraves

The frame is supplied assembled and with no loose parts. Fixing via adjustable frame screws, which providerapid fixing and allow adjustment after fitting.

ThresholdThe Daloc S60 door is supplied with a steel threshold bar, which can be removed after installation if not required.

S60 Fire Doorproduct profile

Page 9: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S60 Fire Door

Standard IronmongeryLock Assa/NemefJournalled hinge in primed steel, with thrust washersDog bolt pin to hinge edgeInternal reinforcement for door closer

Optional ComponentsFitted supplementary lockVision panelRubber kick plateStainless steel kick plateFlexible rubber wipe stripSealing strip in frameCut-out for electric striking plateCut-out for magnetic contact

Cut-out for bolt contactCut-out for cable lead coverVentilation grille (not fire rated)Ventilation grille with shutter (not fire rated)Door closer, not fittedBurglar protection, fittedPanic furniture

Double Leaf Door S602The door leaves and frame are manufactured inthe same way as single door Daloc S601. The inactive leaf is provided with a steelastragal strip and fitted as standard with tworecessed lever-type bolts.

S601 9X20 800 X 1925 900 X 2000 65S601 10X20 900 X 1925 1000 X 2000 70S601 7.5 X 21 650 X 2025 750 X 2100 65S601 8 X 21 700 X 2025 800 X 2100 65S601 8.5 X 21 750 X 2025 850 X 2100 70S601 9 X 21 800 X 2025 900 X 2100 70S601 9.5 X 21 850 X 2025 950 X 2100 80S601 10 X 21 900 X 2025 1000 X 2100 80S601 10.5 X 21 950 X 2025 1050 X 2100 80S601 11 X 21 1000 X 2025 1100 X 2100 80S601 12 X 21 1100 X 2025 1200 X 2100 85S602 13 X 21 1200 X 2025 1300 X 2100 900 90S602 13.5 X 21 1250 X 2025 1350 X 2100 850 95S602 14 X 21 1300 X 2025 1400 X 2100 900 105S602 14.5 X 21 1350 X 2025 1450 X 2100 850 115S602 15 X 21 1400 X 2025 1500 X 2100 800 120S602 15.5 X 21 1450 X 2025 1550 X 2100 850 125S602 16 X 21 1500 X 2025 1600 X 2100 800 130S602 16.5 X 21 1550 X 2025 1650 X 2100 850 135S602 17 X 21 1600 X 2025 1700 X 2100 900 135S602 17.5 X 21 1650 X 2025 1750 X 2100 950 140S602 18 X 21 1700 X 2025 1800 X 2100 900 140S602 18.5 X 21 1750 X 2025 1850 X 2100 950 145S602 19 X 21 1800 X 2025 1900 X 2100 1000 150S602 19.5 X 21 1850 X 2025 1950 X 2100 1050 155S602 20 X 21 1900 X 2025 2000 X 2100 1000 160S602 20.5 X 21 1950 x 2025 2050 x 2100 1050 160S602 21 X 21 2000 X 2025 2100 X 2100 1100 165S602 18 X 24 1700 X 2325 1800 X 2400 900 160S602 21 X 24 2000 X 2325 2100 X 2400 1100 180

Reference Clear Opening Size Structural Opening Size Standard Width WeightW x H in mm W x H in mm Active Leaf in kg.

+ 20 + 10– 5 – 5

Page 10: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S60 Fire Door

Page 11: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S60 Fire Door

Page 12: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThe S50 Archive Door is designed for use to protect document and

archive rooms where the combination of fire and security protection

with aesthetic features to match the office environment.

ApprovalThe S50 door is type tested by SITAC as fire class E120 , manufactured

to strict ISO 9001 Quality Assurance Standards, subject to monitoring

by the Swedish Testing and Research Institute (SP) and SBSC. The S50

has also been tested for its sound reduction properties to EN 140 – 3:

95 that resulted in a sound reduction index Rw of 44dB.

SpecificationThe door leaf has a rolled seam edge and consists of cold rolled steel

that is profiled and bonded together with concealed edge profiles and

internal security reinforcements. In addition a secondary profiled steel

section is affixed to the back of the leaf to increase the doors sound

and fire capabilities. The door construction methods are unique and

the door is therefore patent- protected.

Door LeafThickness : 105mm

Finish : Supplied as standard pre-painted white, other NCS / BS / RAL colours are available to order.

Alternatively the door can be supplied primed only.

Insulation : Mineral Wool

FrameStandard : Frame 41 with fixed architrave on the front face.

Finish : Supplied as standard pre-painted white but is also available in other NCS / BS / RAL colours.

Alternatively, the door can be supplied primed.

Insulation : Fitted with Mineral Wool

Manufactured in 1.5mm cold rolled type HSLA 350YP steel.

Several different types are available: Architrave on the front face, architrave to both sides or without

architrave. Fixing is via adjustable frame screws, which provide rapid fixing and allow adjustment after fitting.

product profile

S50 Archive Door

Page 13: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S50 Archive Door

ThresholdThe door set is supplied with a rebated threshold bar in stainless

sheet metal.

Standard IronmongeryLock ASSA 8765 excluding cylinder.

Fixed Pin hinges, galvanised.

Three dog bolts to hinge edge.

Internal re-inforcements for door closer.

Optional ComponentsCut –Out for magnetic contact

Cut – Out for bolt contact

Lock ASSA 1926 with archive handle and escutcheons.

Door Closer – not fitted.

Stainless steel kick plates

Access Control Equipment can be fitted

S50 -120 10x21 900 x 2025 1000 x 2100 125

Reference Clear Opening Size Structural Opening Size WeightW x H in mm W x H in mm in kg.

+ 20 + 10– 5 – 5

Page 14: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S50 Archive Door

Page 15: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S50 Archive Door

Page 16: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThe S20 DALOC hinged fire door has been designed to meet the highest demands for a pre-painted internal

door where fire resistance, sound reduction and aesthetic requirements are combined.

ApprovalThis door is a CERTIFIRE approved fire door (Certificate- 248) tested to BS476 Part 22 to 240 minutes. The Door

also meets the relevant requirements of BS5588. Doors with seals fitted to the frame have successfully

completed panel smoke passage to BS476 Part 31-1. The S20 also has a sound reduction index of Rw 30dB,

tested to SS-EN ISO 140-3:95.

The door construction and manufacturing methods are unique and the door is therefore patent-protected

(European patent 0332648).

SpecificationThe doorleaf has a straight edge and consists of 1 mm cold-rolled steel that is profiled and bonded together

with concealed edge profiles to give the doorleaf a blemish free smooth even surface.

DoorleafThickness 47 mm

Finish Supplied as standard pre-painted white.

Other BS/RAL colours are available to order.

Alternatively the door can be supplied primed

Insulation Mineral wool

FrameStandard Frame 41 with fixed architraves on the front face

Finish Supplied as standard pre-painted white, but

also available in other BS/RAL colours or primed

Insulation Filled with mineral wool

Manufactured in 1.5 mm cold-rolled type HSLA 350YP steel.

Several different types are available:

• Architraves on the front face

• Architraves on both sides or without architraves

S20 Hinged Fire Doorproduct profile

Page 17: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S20 Hinged Fire Door

S201 9 x 21 800 x 2025 900 x 2100 65S201 10 x 21 900 x 2025 1000 x 2100 70S201 11 x 21 1000 x 2025 1100 x 2100 75S201 12 x 21 1100 x 2025 1200 x 2100 80S201 13 x 21 1200 x 2025 1300 x 2100 85S202 15 x 21 1400 x 2025 1500 x 2100 925 100S202 18 x 21 1700 x 2025 1800 x 2100 925 115S202 18 x 24 1700 x 2325 1800 x 2400 925 130S202 21 x 24 2000 x 2325 2100 x 2400 1025 150

Reference Clear Opening Size Structural Opening Size Standard Width WeightW x H in mm W x H in mm Active Leaf in kg.

+ 20 + 10– 5 – 5

The frame is supplied assembled and with no

loose parts. Fixing via adjustable frame screws,

which provide rapid fixing and allow adjustment

after fitting.

ThresholdThe Daloc S20 door is supplied with a stainless

sheet metal threshold bar. If required, the door can

be fitted with an optional oak threshold or with a

fitted flexible rubber wipe strip on the doorleaf.

Standard IronmongeryLock Assa/Nemef

Fixed pin hinge, galvanised

Dog bolt pin to hinge edge

Internal reinforcement for door closer

Optional ComponentsFitted supplementary lock

Vision panel

Rubber kick plate

Stainless steel kick plate

Flexible rubber wipe strip

Sealing strip in frame

Cut-out for electric striking plate

Cut-out for magnetic contact

Cut-out for bolt contact

Cut-out for cable lead cover

Door closer, not fitted

Double Leaf Door S202The door leaves and frame are manufactured in

the same way as single leaf S201 Daloc door. The

inactive leaf is provided with a steel astragal strip

and fitted as standard with two recessed lever-

type bolts.

Page 18: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S20 Hinged Fire Door

Page 19: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

S20 Hinged Fire Door

Page 20: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThis unique roller shutter is specifically

designed for use in retail outlets within large

open plan shopping malls frequented by large

numbers of the general public. It combines

optimum fire protection with aesthetic appeal.

It stays hidden from view when not needed and

sweeps into action in the event of fire to

prevent the transfer of heat from one area to

another. It is also suitable for underground car

parks and warehouses.

ApprovalsThe Pyroshield System G Fire Shutter is tested

and approved as a fully insulated shutter by the

`Institut fùr Bautectnik Berlin’ to DIN 4102 at 90

minutes. Tested in the UK to BS 476: Part 8 for

three hours insulation.

Results:Integrity – 285mins

Insulation – 193mins

SpecificationCurtain & Roller: Manufactured from purpose designed inter-locking steel laths in galvanised finish. The

curtain is fully lined with a ceramic fibre blanket to offer protection from radiated heat. The roller is made

from seamless steel tube mounted on stub shafts running in bearing houses.

Support StructureManufactured in galvanised steel and lined out with rockwool ceramic fibre, the structure supports the Roller

and forms the guide for the curtain.

Drive SystemThe Pyroshield Curtain is power driven in operation by a 3ph geared motor mounted on an adjacent mounting

plate. Drive to the shutter barrel is via roller chain system.

ControlsThe shutter control system will work with existing fire alarm or as a stand alone system. Photo-electric calls can

be introduced to prevent the shutter closing onto objects or personnel in the opening.

product profilePyroshield System GRolling Fire Shutter

Page 21: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

Pyroshield System GRolling Fire Shutter

System G Dimensions

a) allowance for bearing and sprocket on width

b) concrete overhang above

c) distance, overhead suspension of curtain

d) shutter closure section depth

e) floor space required for curtain

Clear Clear a b c Minimum e fWidth Height mm mm mm Lintel mm mm

d mm

1500-7000 1200-2000 150 830 710 640 200 630

1500-6750 2001-2500 150 830 710 680 200 630

1500-6500 2501-3000 150 830 710 730 200 630

1500-6250 3001-3500 150 915 795 785 210 705

1500-6000 3501-4000 150 945 825 830 240 705

1500-5750 4001-4500 150 965 845 865 260 705

7001-12000 1200-2000 250 835 715 700 130 705

6751-12000 2001-2500 250 855 735 730 150 705

6501-12000 2501-3000 250 950 830 840 180 770

6251-12000 3001-3500 300 1000 880 890 180 820

6001-12000 3501-4000 300 1040 920 940 220 820

5751-12000 4001-4500 300 1060 940 960 240 820

Page 22: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThis “unique” four hour rated fire door system that

combines cost effectiveness with unparalleled safety for

people and property is primarily designed for use in open

plan areas where compartment walls would restrict or

impede product manufacture. It can also be used in

exhibition Halls, and large warehouses. In the event of a

fire, the curtain is activated and lowered to prevent the

spread of fire from one area to another.

Protecting LifeBecause of its unique design the irrigated fire curtain can

be activated immediately without the time delays

associated with conventional barrier systems. Personnel

working within the affected area can pass between the curtain panels to reach a safe exit without destroying

the integrity of the fire screen.

Equally important, the work of firemen alerted to the scene is made easier by the fact that they are able to

observe and put out the fire through the slits without reducing the fire screen efficiency.

ApprovalThis curtain is tested and assessed to BS476 pt 22, 1987, ISO 3008 and Australian Standard 1530.4.1985 for over

240minutes Integrity and insulation. It also has full assessments covering its use to the maximum sizes of

16metres wide by 5metres high.

Features

• The irrigated fire curtain is compatible with any type of fire detection system

• Permits access through the curtain by personnel trapped in the fire area without affecting fire resistant integrity

• Enables Fire Brigade personnel attending the scene to observe the fire through the slits and put out the fire

without reducing the fire screen efficiency.

• Cost effective to install.

• Greater spans can be covered with a single curtain compared with conventional barriers (maximum span = 5

metres high, 16 metres wide).

• Neat and unobtrusive appearance.

product profile

Irrigated Fire Curtain

Page 23: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

Irrigated Fire Curtain

StructureEach curtain is made up of individual double layered overlapping panels of absorbent and highly fire

resistant material, to provide total coverage. At the bottom of each panel there is a hem which houses a

steel weight which assures constant gravity pull on the curtain. The bottom of each panel is finished with a

“skirt” which provides a perfect seal with the floor. The lateral seal is guaranteed by running the curtain

and steel weight in the two vertical guide grooves of the metal framework. Built into the frame and

connected to the guides, are two housings containing the mechanism for the irrigation system, the

automatic curtain release system and the system to control the lowering of the curtain. The top casing of

the framework houses the rolled-up curtain, the irrigation ducts and the curtain mechanism.

IrrigationThis is provided by three ducts at the top comprising copper tubes of variable diameter according to the

amount of water needed for the curtain surface. These three ducts are connected to a valve that is

controlled by the automatic or manual release mechanism.

The curtain must be connected to a water supply that functions even if other failures occur, at a rate of

12.5 litres/square metre/minute (0.25 gallons*/square feet/minute) and minimum pressure of around 2 bars

(30 pounds/square inch).

(NB – Flow rates given are average. Specific rates and pressures are calculated to suit opening sizes)..

(*Imperial Gallon)

Release SystemIn the event of a fire, hot gases, smoke or a rise in temperature will active the detection system, which in

turn activates a circuit breaker to lower the curtain in position. In addition the curtain is impregnated

with water that ensures a perfect seal, hermetically blocking both the flames and smoke. The system can

also be brought into operation automatically by a fusible link, set at 70o, or manually using a “pull

release” handle.

Page 24: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

Irrigated Fire Curtain

Page 25: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionTyco Fire and Integrated Solutions manufacture and supply a wide range of

fusible links, electromagnetic hold / release devices, speed governors and specially

developed control equipment for the use with fire dampers, doors and shutters.

Fusible LinksSoldered fusible links are most commonly used in fire dampers, vents and

shutters. They are simple devices designed to ‘break’ at specific

temperatures to ensure that the product closes in time of fire.

Quartzoid Bulb links work in a similar fashion as the soldered link and

are used in similar products but use a frangible bulb, similar to those

used in sprinkler systems, as the means of detecting rise in

temperature. Variations of these links can also be connected to the fire

alarm circuits for remote release.

Release & Control DevicesVarious designs of release devices are available for use with doors and

shutters but all are connected to the alarm circuit for remote

activation, either by impulse or de-energisation and all forms are

re-settable after activation.

Controlling the speed of closure once released is important to prevent

injury to personnel in the vicinity or indeed damage to the product itself.

Devices, normally hydraulic, can be installed on doors and shutters to

allow controlled closure to meet forthcoming EN regulations.

Control EquipmentOur fire control panel is a digitally programmable and is designed

specifically for use on fire doors and shutters. The panel can act as an

interface between the fire product and existing on site alarm systems or,

with the addition of suitable detectors, etc., can act as a stand-alone

system. The panel also incorporates audio / visual warnings and time

delay circuits for use where personnel are likely to be in the vicinity of

the closing door or shutter.

Contact our dedicated sales team in our Manchester office for further

details on products.

NOTE :

All fire products that incorporate any of the above equipment should be

inspected and tested twice annually to ensure their continued efficiency.

Fusible LinksRelease and Control Devices for Fire Products

product profile

Manchester Head Office

Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL.Tel: 0161 205 2321Visit our website at: wwwwww..ttyyccooffiiss..ccoo..uukk

Page 26: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThese doors are fitted into compartment walls to confine

an outbreak of fire to the smallest area. They are designed

to resist the intense heat applied to one side of the door

without excessive distorting, and its thermal conductivity is

low enough to prevent the ignition of combustible

materials in the adjoining area.

ApprovalApproved to BS.476 Part 22 W.F.R.C. No. 54275

Specification End Plates6 mm mild steel plate mounted on 75 x 75 x 6 mm mild

steel angle.

Size of end plate depends on door size.

All fixings are 12 mm or 10 mm dia.

Endplates incorporate 50 x 50 x 6 mm mild steel angle

support brackets for coil casing

BarrelConstructed from mild steel tube with helical counter balance springs mounted on mild steel shafts with

bearing blocks at each end incorporating high speed bearings. Tube and shaft size are specific to door size.

CurtainConstruction from 75 mm wide x 20 SWG curled interlocking galvanised steel lath with steel endlocks.

Endlocks riveted to lath with mild steel rivets.

Lath fixed to barrel unit by M10 screws at Maximum centres 400.

Bottom RailCold rolled galvanised steel ‘T’ section bottom rail.

Guides75 x 30 x 3 mm thick mild steel guides bolted and welded to 75 x 75 x 6 mm mild steel angles.

Mild steel angles required to have slotted fixing holes.

All fixings M10 complete with fusible washers.

The above guides and angles to incorporate 65 x 25 x 3 mm mild steel dropper bar guide, used on small self

coiling units only.

2 & 4 Hour Fire ResistantRoller Shutter Doors

product profile

Page 27: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

2 & 4 Hour Fire ResistantRoller Shutter Doors

Coil CasingGalvanised steel coil casing fixed to angles on end plate by M8 screws and fixed back to wall by

M8 rawlbolts.

Maximum centres of fixing 600.

OperationSelf coiling, hand chain or hand wheel, or via electric motor with controlled descent and connected to

fusible link and drop bar, or solenoid for connection to fire alarm.

In an emergency the unit is totally mechanical in operation.

Manually operated doors are supplied with speed governors for added safety.

Electrical OperationSingle phase or 3 phase units are mounted on the end plate with reduction gearing.

In the event of a power failure emergency opening operation can be undertaken by hand chain.

N.B. Fire Resistant Roller Shutters are not designed for continual use. However, motor driven fire shutters

can be utilised for security purposes if opened and closed once a day.

Method of Operation1) Fusible/Quartzoid bulb link

2) Thermo-electric bulb link

3) Solenoid Release

4) Motor drive

5) Interaction with Fire Detection and Alarm systems

Safety and Service ConsiderationsAll Fire Shutters should be serviced and drop tested regularly at no more than 6 month intervals. Our

Service department will contact you after the installation has been completed and advise you of our

Tyco Fire and Integrated Solutions Door-Care maintenance scheme.

Optional ExtrasPolyester powder coating to BS/RAL colour range.

Electric Operation

Electrical wiring from isolator plus commissioning (Note: fire alarm connections by others)

Stand alone detection systems – Fire/Smoke etc.

Interface control systems

Page 28: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

2 & 4 Hour Fire ResistantRoller Shutter Doors

Page 29: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThese horizontal and vertical sliding doors are fitted into compartment walls to confine an outbreak of fire to

the smallest area. Sliding doors are the most reliable of all fire protection products in closing off an opening.

They have fewer moving components to go wrong and do not rely on latching mechanism to keep them closed.

ApprovalThe door construction has been tested at the Warrington Fire Research Centre to BS.476 Part 8: 1972, and

achieved the following results.

Stability 240 minutes (test discontinued at this point)

Integrity 240 minutes (test discontinued at this point)

Insulation 8 minutes

The door manufacturing process is quality controlled at all stages with ISO 9001 : 2000 quality standards,

independently audited by the L.P.C.B.

product profileD102/103 2/4 Hour Rated Horizontal and

Vertical Sliding Fire Resisting Door Set

Page 30: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

D102/103 2/4 Hour Rated Horizontal and Vertical

Sliding Fire Resisting Door Set

SpecificationLeaf Construction1.5 mm Zintec sheet faces enclose suitable 2 mm

steel stiffening channels – the whole surrounded

by 2.5 mm border channels. Total leaf thickness =

48 mm. Site delivered in grey zinc chromate

primer for immediate on-site painting by others.

TrackingThe door leaf is top hung from an overhead H.C.

totally enclosed horizontal steel track, by means

of 4-wheeled “lubricated for life” roller bearing

adjustable trolley hangers, allowing easy day to

day manual operation. No bottom track is

required as the door is guided by a single guide

roller. Vertical doors run in enclosed side guides

which extend all around the opening. These also

act as the smoke frame for the door.

Smoke FrameThe door is supplied as standard with smoke

frame and suitable fixings to both jambs and

lintel, interlocking with the door leaf when closed.

Self ClosingAutomatic self closing is available if required, by means of a fusible link/weight system activated at 68oC.

This system does not interfere with normal day to day manual operation.

Maximum structural opening sizes : 2286 wide x 2440 mm high. Larger door sizes can be provided with

approval gained from the appropriate authorities.

OptionsThermo-electric quartzoid bulb link release

Solenoid release

Power operation - electrical or pneumatic

Vision panels

Inclined track closing system

Hold open magnets

Wicket gate arrangement (horizontal doors)

Insulated (Fire) versions available

Page 31: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

D102 2/4 Hour Rated Horizontal

Sliding Fire Resisting Door Set

Page 32: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

D103 2/4 Hour Rated Vertical

Sliding Fire Resisting Door Set

Page 33: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

DescriptionThe SD3 Smoke Curtain is specifically designed

for use in large open plan shopping malls,

exhibition Halls and leisure facilities

frequented by large numbers of the general

public. Under normal conditions, the smoke

curtain remains unseen. It is mounted in a

smoke curtain head box contained within the

ceiling void.

Approval The complete Smoke Curtain System fully

complies with BS 7346 Part 3. The fabric has

been tested to B.S.476 Parts 6, 7 and 20 to

withstand temperatures of up to 1000°C after

60 minutes minimum

SpecificationThe automatic smoke curtain consists of an X32A woven glass fibre cloth, weight 415g/sq.m coated with

20g/sq.m each side of micronised aluminium polymer giving a minimum fabric weight of 455g/sq.m. This is

wound onto an octagonal tube, each of which incorporates a 24volt D.C motor, a sealed heavy-duty ball

bearing assembly, and an electronic control circuit.

Fixing arrangementThe automatic roller assemblies, incorporating the fabric, are to be housed in galvanised mild-steel head boxes,

which are normally supported from a framework of Unistrut channel and M10 studding.

Standard head box sizes shall be 150mm x 150mm for single rollers (maximum width six metres) and 250mm x

150mm for multiple rollers (over six metres wide). Larger head boxes may be required where the curtain drop is

in excess of four metres.

Electrical OperationOperation of the curtain is via the Group Control Panel that can either be mounted adjacent to the smoke

curtain head boxes within the ceiling void, allowing access for maintenance, or mounted in a remote position

from the curtains. The panel requires a local 240v ac supply rated at 3 amps via an unswitched fused spur on a

maintained supply installed by others.

For operational purposes the Group Control Panel must be connected to a normally closed volt-free contact

within the fire alarm control panel, using Belden 8761 cable. The alarm cable shall be monitored by an end of

line device, immediately lowering the smoke curtains to their operational position should a short circuit or fault

be detected.

SD3 Smoke Curtainproduct profile

Page 34: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

SD3 Smoke Curtain

Each control panel is capable of operating

up to ten rollers and includes battery back-

up, which will maintain the curtains in their

retracted position for a period of three

hours during a mains failure. It will also

possible to manually operate the curtains for

twenty cycles during this period.

Should the battery voltage fall below a pre

determined limit, a low voltage cut off

circuit will activate the curtain, which will

descend in a controlled manner under the

power of gravity.

The roller motors, which are 24 volt D.C.,

must be wired from the G.C.P. in a ring main

using suitably sized cable to ensure a voltage

of 24v D.C. -10%. The curtains automatically

descend upon receipt of a signal from the

fire-alarm panel and automatically retract

when the signal is removed. During ascent

the motors are controlled via a synchronised

speed circuit to ensure all curtains are raised

at similar rates. The curtains descend under

the power of gravity at all times, including

total mains and battery back up failure.

The lower edge of the curtains incorporate a formed metal section that acts as a weight bar to enable the

curtain to unwind upon receipt of a signal from the fire alarm panel or total mains and battery failure.

The weight bar shall also prevent deflection as detailed in B.S. 7346 Part 3.

A poly carbonate extrusion is fitted to the angle for aesthetic purposes and to provide a stop against the

underside of the head box or stopping mechanism.

Limit switches are not to be used to control the upper and lower positions of the curtain.

Page 35: product profile D100/D101 Fire Resistant Door - · PDF fileSelf-closing action is available if required, ... Internal reinforcement for door closer. Optional Components Fitted supplementary

SD3 Smoke Curtain


Recommended