22
SVK Water Chiller Plug-in water chillers. Cooling capacity from 15 to 130 kW. ® Competence and experience in industrial cooling systems VWK Desk unit VWK Shell & Tubes DIN EN ISO 9001 Zertifikat: 09 100 5300 VWK SVK TRK CHILLY LWK Special Product range HYFRA Industriekühlanlagen GmbH Industriepark 54 · D-56593 Krunkel Phone: +49 (0) 26 87 / 8 98 - 0 · Fax: +49 (0) 26 87 / 8 98 - 25 · E-mail:[email protected] www.hyfra-pedia.com In addition to our standard product range, we offer you solutions for liquid cooling in all industrial applications. Our systems are available in compact or split design, air or water cooled. Continuous-flow recoolers and expansions with cleanable plate-type heat exchangers are just as available as versions with special voltages. Our sales team of engineers and technicians is always available to you for comprehensive consultation. Do not hesitate in contacting us. TRK - Immersion chiller for cooling lubricants with a cooling capacity of 2 to 75 kW. Service-friendly in maintenance and cleaning CHILLY - cooling-water chiller with a cooling capacity of 0.8 to 4.5 kW, with tank and pump. Space-saving and reliable. LWK - Air-type water recooler without refrigeration system with a cooling capacity of 2 to 2.5 kW, with tank and pump. The low-cost alternative for applications with higher water operating temperatures. VWK/1 - Water chiller with a cooling capacity of 2 to 70 kW, with tank and pump. Compact design with high temperature accuracy.
Transcript
Page 1: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

SVKWater Chiller

Plug-in water chillers.Cooling capacity from 15 to 130 kW.

®

Competence and experience in industrial cooling systems

VWKDesk unit

VWKShell & Tubes

DIN EN ISO 9001Zertifikat: 09 100 5300

VWK

SVK

TRK

CHILLY

LWK

Special

Product range

HYFRA Industriekühlanlagen GmbHIndustriepark 54 · D-56593 KrunkelPhone: +49 (0) 26 87 / 8 98-0 · Fax: +49 (0) 26 87 / 8 98-25 · E-mail:[email protected]

www.hyfra-pedia.com

In addition to our standard product range, we offer you solutions for liquid cooling in allindustrial applications.Our systems are available in compact or split design, air or water cooled.Continuous-flow recoolers and expansions with cleanable plate-type heat exchangers arejust as available as versions with special voltages.Our sales team of engineers and technicians is always available to you for comprehensiveconsultation. Do not hesitate in contacting us.

TRK - Immersion chiller for cooling lubricantswith a cooling capacity of 2 to 75 kW.Service-friendly in maintenance and cleaning

CHILLY - cooling-water chiller with a coolingcapacity of 0.8 to 4.5 kW, with tank and pump.Space-saving and reliable.

LWK - Air-type water recooler without refrigerationsystem with a cooling capacity of 2 to 2.5 kW,with tank and pump. The low-cost alternative forapplications with higher water operatingtemperatures.

VWK/1 - Water chiller with a cooling capacityof 2 to 70 kW, with tank and pump. Compactdesign with high temperature accuracy.

Page 2: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

SVK water chiller Technical data

Cooling capacitiesStandardequipment:� Stainless steel frame

� Coaxial evaporator

� High tech scroll compressor /

low noise

� High efficiency air cooled

condensor

� Digital thermostat

hysteresis +/- 1 K

� Refrigerant circuit with TÜV approved low and high

pressure switch

� Chiller IP 54

� Operating temp. 42° C max. ambient

� Default light - control circuit

� Common alarm (potential free)

� Drain valve for tank

� Anti frost thermostat

� Water manometer

� By-Pass valve

� Water level switch

� External pump's start-up on main-switch

� Low noise level (star-delta)

� CH-pump with carbide / carbide shaft seal

Options:� DC voltage - control circuit

� Winter start up regulation (0-50-100%)

� Water set point 40° C max.

� Hand shut off valve between tank and pump

� Wire labelling

� Harting connectors / plugs

� Refrigerant R 134 A

� Non return valve + magnetic valve (outside)

� Hysteresis +/- 0,3 K

� Air filter

� Stop process with low/high temperature

alarm

� CR-pump for pressure above 3 bar with

carbide / carbide shaft seal

� Stainless steel piping

SVK SVK SVK SVK SVK SVK SVK SVK SVK SVK SVK SVK SVK140/1 180/1 220/1 270/1 320/1 360/1 540/1 440/1/2 540/1/2 640/1/2 720/1/2 1080/1/2 1250/1/2

Ambient air Water Cooling capacities in kW

10° C 14,1 16,9 21,4 25,7 31,4 38,9 51,4 42,9 51,4 62,9 78,6 101,6 123,6

32° C 15° C 16,6 20,0 25,3 29,9 37,0 45,5 59,9 50,7 59,9 74,1 92,7 119,7 144,6

20° C 18,3 21,7 28,0 33,5 41,5 51,8 67,1 56,0 67,1 83,1 100,4 129,5 156,5

10° C 13,1 16,4 20,2 23,9 29,6 35,2 47,9 40,5 47,9 59,2 73,8 94,5 113,6

37° C 15° C 15,7 19,2 23,9 28,2 34,9 42,1 56,5 47,8 56,5 69,8 86,6 110,8 134,6

20° C 17,2 20,5 26,2 31,1 37,9 49,0 62,4 52,4 62,4 75,9 94,7 120,3 145,6

10° C 12,9 15,6 19,6 22,9 25 33,3 45,8 39,3 45,8 50,0 66,1 90,0 100,5

42°C 15° C 15,4 18,5 22,9 27,4 30,9 40,2 54,9 45,8 54,9 61,9 79,9 108,0 118,5

20° C 17,0 20,1 25,6 30,2 35,0 47,3 60,6 51,3 60,6 70,0 87,6 119,5 128,5

SVK SVK SVK SVK SVK SVK SVK SVK SVK SVK SVK SVK SVK140/1 180/1 220/1 270/1 320/1 360/1 540/1 440/1/2 540/1/2 640/1/2 720/1/2 1080/1/2 1250/1/2

Compressor type ZR 72 ZR 90 ZR 11 ZR 12 ZR 16 ZR 19 ZR 250 ZR 11 ZR 12 ZR 16 ZR 19 ZR 250 ZR 310(number) 1 1 1 1 1 1 1 2 2 2 2 2 2

Power consumptioncompressor kW 6,2 7,9 9,7 11,1 14,6 16,8 24,6 19,4 22,2 29,2 33,6 49,2 60,0

Power consumptionmax. kW 9,0 10,7 12,5 14,6 18,4 21,2 31,4 24,8 29,1 36,1 42,4 62,8 71,6

Current max. A 15,6 18,9 21,5 25,3 31,1 34,8 52,1 42,9 50,9 63,3 69,6 104,2 119,5

Air flow rate max. m3/h 9.300 9.300 9.300 9.200 9.200 14.400 17.000 18.600 18.400 18.400 28.800 34.000 36.800

Water tank volume l 330 330 330 330 330 390 390 660 660 660 720 720 720

Water pressuree bar 3,8 3,6 3,2 3,0 3,2 3,0 3,6 4,0 3,6 3,0 3,2 3,0 2,8

Nominal water flow* m3/h 2.9 3,5 4,3 5,1 6,5 7,0 10,3 8,0 10,3 12,7 14,0 20,6 25,0

Water connections Grundfos CH4-60 CH4-60 CH4-60 CH4-60 CH8-50 CH8-50 CH12-50 CH12-50 CH12-50 CH12-50 CR 32-2 CR 32-2 CR 32-2inlet/outlet inch 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 2 2 2 2 1/2 2 1/2 2 1/2

Water connections feed inch 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8

Length (L) mm 1000 1000 1000 1000 1000 1500 1500 2000 2000 2000 1500 1500 2000

Width (B) mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 2000 2000 2000

Height (H) mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000

Weight (approx.) kg 320 370 400 400 410 485 520 795 800 810 870 940 1400

Power supply 3/PE/400 V/50 Hz.Control voltage 24 V AC. All technical data is valid for machines with a maximum ambient temperature of + 42° C.� Nominal flow at: 32° C ambient temp. / 15° C water temp. / 5 K diff. temp. between water in-outlet.Specifications subject to change.

Temperatures

Specifications

Easy access to the tank and evaporator manualfill in and cleaning

Coaxial evaporator inside the tank

Page 3: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

TRKImmersion Recooler

Plug-in plug-out water chillerCooling capacity from 2 to 70 kW

®

Competence and experience in industrial cooling systems

VWK

SVK

TRK

CHILLY

LWK

Special

VWKDesk Unit

DIN EN ISO 9001Zertifikat: 09 100 5300

VWKShell & Tubes

Product range

HYFRA Industriekühlanlagen GmbHIndustriepark 54 · D-56593 KrunkelPhone: +49 (0) 26 87 / 8 98-0 · Fax: +49 (0) 26 87 / 8 98-25 · E-mail:[email protected]

www.hyfra-pedia.com

In addition to our standard product range, we offer you solutions for liquid cooling in allindustrial applications.Our systems are available in compact or split design, air or water cooled.Continuous-flow recoolers and expansions with cleanable plate-type heat exchangers arejust as available as versions with special voltages.Our sales team of engineers and technicians is always available to you for comprehensiveconsultation. Do not hesitate, we are awaiting your enquiry!

VWK/1 - Water chiller with a cooling capacityof 2 to 15 kW, with tank and pump. Compactdesign with high temperature accuracy.

CHILLY - cooling-water chiller with a coolingcapacity of 0.8 to 4.5 kW, with tank and pump.Space-saving and reliable.

LWK - Air-type water recooler without refrigerationsystem with a cooling capacity of 2 to 2.5 kW,with tank and pump. The low-cost alternative forapplications with higher water operatingtemperatures.

SVK - Water chiller with a cooling capacity of15 to 70 kW, with tank and pump. Compactdesign with high temperature accuracy.

Page 4: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

Basket evaporator

Competence and Experience in Industrial Cooling Systems

Temperatures

TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK20 30 50 70 90 110 140 180 220 270 320 360 440 540 640

Number of Scroll-compressors 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2

Power consumptioncompressor max. kW 1,4 2,0 2,6 3,1 4,3 5,9 6,2 7,9 9,7 11,1 15,5 15,8 19,4 22,2 31,0

Power consumptionmax. kW 2,0 2,8 3,4 3,9 5,3 7,0 7,5 9,2 11,0 12,9 17,6 18,4 22,0 25,7 34,5

Currentmax. A 3,5 4,9 5,8 6,7 9,3 12,5 13,2 16,5 19,1 22,9 30,1 32,9 38,1 45,5 58,3

Air flow rate max. m3/h 2800 4500 4500 4500 5500 6100 9300 9300 9300 11000 12600 18600 18600 22000 25200

Length (L) mm 785 785 785 785 785 785 1085 1085 1085 1085 1085 2085 2085 2085 2085

Width (B) mm 785 785 785 785 785 785 1085 1085 1085 1085 1085 1085 1085 1085 1085

Total Height (H) mm 1215 1215 1215 1315 1315 1315 2000 2000 2000 2000 2000 2000 2000 2000 2000

Height of machinery top (h) mm 715 715 715 715 715 715 1340 1340 1340 1340 1340 1340 1340 1340 1340

Length of immersion part (l) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 2000 2000 2000 2000

Width of immersion part (b) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 1000 1000 1000 1000

Immersion deepth (E) mm 500 500 500 600 600 600 660 660 660 660 660 660 660 660 660

Minimum coolant levelfor coil evaporator (M) mm 300 300 300 500 500 500 500 500 500 500 500 500 500 500 500

Minimum coolant levelfor flat evaporator (M) mm 60 60 80 80 80 110 130 150 180 220 240 150 180 220 240

Weight (approx.) kg 130 140 140 150 160 160 260 320 330 350 370 630 650 690 730

Power supply: 3/PE/400V/50Hz Control voltage 24 V AC All technical data are valid for machines for a maximum ambient temperature of + 42° C.

TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK

20 30 50 70 90 110 140 180 220 270 320 360 440 540 640

Ambient air Emulsion Oil Coling capacities in kW

10° C 15° C 2,3 3,6 5,6 7,0 10,1 12,2 14,8 17,6 22,1 26,4 32,1 35,3 44,3 52,8 64,3

32° C 15° C 20° C 2,8 4,4 6,6 8,2 11,9 14,3 17,3 20,7 26,0 30,6 37,7 41,4 52,1 61,3 75,5

20° C 25° C 3,1 4,9 7,3 9,1 13,0 15,8 19,0 22,4 28,7 34,2 42,2 44,9 57,4 68,5 84,5

10° C 15° C 2,2 3,2 5,5 6,4 9,5 11,3 13,8 17,4 20,9 24,6 30,3 34,8 41,9 49,3 60,6

37° C 15° C 20° C 2,6 4,0 6,5 7,6 11,1 13,4 16,4 20,7 24,6 28,9 35,6 41,4 49,2 57,9 71,2

20° C 25° C 3,0 4,5 7,1 8,3 12,2 14,8 17,9 22,4 26,3 31,8 38,6 44,9 52,7 63,8 77,3

10° C 15° C 2,1 3,6 5,1 6,3 9,1 9,5 13,6 16,3 20,3 23,6 25,7 32,8 40,7 47,2 51,4

42°C*) 15° C 20° C 2,5 3,8 6,1 7,5 10,6 11,8 16,1 19,2 24,2 28,1 31,6 38,4 48,5 56,3 63,3

20° C 25° C 3,0 4,3 6,8 8,3 11,6 13,4 17,7 21,1 26,3 30,9 35,7 42,3 52,7 62,0 71,4All standard machines are specified for a maximum ambient temperature of + 37° C.*) Machines for + 42° C maximum ambient temperature are available at extra cost. Machine sizes will not change.

TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK TRK20 30 50 70 90 110 140 180 220 270 320 360 440 540 640

Number of Scroll-compressors 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2

Power consumptioncompressor max. kW 1,4 2,0 2,6 3,1 4,3 5,9 6,2 7,9 9,7 11,1 15,5 15,8 19,4 22,2 31,0

Power consumptionmax. kW 2,0 2,8 3,4 4,0 5,4 7,2 7,7 9,6 11,4 13,2 17,9 18,4 22,7 26,3 35,1

Currentmax. A 3,5 4,9 5,8 7,3 9,8 13,1 13,7 17,7 20,3 24,0 31,2 34,0 40,6 48,0 60,8

Air flow rate max. m3/h 2800 4500 4500 4500 5500 6100 9300 9300 9300 11000 12600 18600 18600 22000 25200

Length (L) mm 785 785 785 785 785 785 1085 1085 1085 1085 1085 2085 2085 2085 2085

Width (B) mm 785 785 785 785 785 785 1085 1085 1085 1085 1085 1085 1085 1085 1085

Total Height (H) mm 1215 1215 1215 1315 1315 1315 2000 2000 2000 2000 2000 2000 2000 2000 2000

Height of machinery top (h) mm 715 715 715 715 715 715 1340 1340 1340 1340 1340 1340 1340 1340 1340

Length of immersion part (l) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 2000 2000 2000 2000

Width of immersion part (b) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 1000 1000 1000 1000

Immersion deepth (E) mm 500 500 500 600 600 600 660 660 660 660 660 660 660 660 660

Minimum coolant levelfor flat evaporator (M) mm 110 110 130 150 150 200 220 240 340 410 520 240 340 410 520

Weight (approx.) kg 140 140 150 160 170 180 290 350 360 390 420 690 710 770 830

Power supply 3/PE/400 V/50 Hz. Control voltage 24 V AC. All technical data is valid for machines with a maximum ambient temperature of + 42° C.

Specifications subject to change.

TRK immersion recooler

Standard equipment:� Agitator for better heat transfer

� Stainless steel frame

� Stainless steel coil evaporator

� Chiller IP 54

� Operating temperature max. 37° C ambient

� High tech. scroll compressor / low noise

� High efficiency air cooled condensor

� Digital thermostat mit hysteresis +/- 1,0 K

� Refrigerant circuit with TÜV approved

high pressure switch

� Environment friendly refridgerant R407C

� CE-Standard / ISO 9001 / EN 60204

� Air filter

� All systems with control transformer.

no neutral required

Options:� DC-voltage - control circuit

� Winter start up regulation (0-50-100%)

� Common alarm (potential free)

� Special voltage

� Mediumtemperature max +40° C

� Wire labelling

� Harting connectors / plugs

� Refrigerant R 134 A

� Hysteresis +/- 0,3 K

� Stop process with low/high temperature

alarm

� Fat evaporator for low medium level

� Gear agitator for oil

� Operating temperture ≥ 37° C ambient

� Water cooled condensor

� Centrifugal fan for ≤ 150 Pa ext. pressure

� Differential control of the cooling-

lubricant temperature dependent on ambient

or machine bed temperature

Technical data

Cooling capacities

Specification for emulsion

Specification for oil

Air OUT

Air IN

Page 5: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

VWK/1Water Chiller

Plug-in water chillers.Cooling capacity from 2 to 70 kW

®

Competence and experience in industrial cooling systemsDIN EN ISO 9001

Zertifikat: 09 100 5300

VWKDesk Unit

VWKShell & Tubes

VWK

SVK

TRK

CHILLY

LWK

Special

Product range

HYFRA Industriekühlanlagen GmbHIndustriepark 54 · D-56593 KrunkelPhone: +49 (0) 26 87 / 8 98-0 · Fax: +49 (0) 26 87 / 8 98-25 · E-mail:[email protected]

www.hyfra-pedia.com

In addition to our standard product range, we offer you solutions for liquid cooling in allindustrial applications.Our systems are available in compact or split design, air or water cooled.Continuous-flow recoolers and expansions with cleanable plate-type heat exchangers arejust as available as versions with special voltages.Our sales team of engineers and technicians is always available to you for comprehensiveconsultation. Do not hesitate, we are awaiting your enquiry!

TRK - Immersion chiller for cooling lubricantswith a cooling capacity of 2 to 70 kW.Service-friendly in maintenance and cleaning

CHILLY - cooling-water chiller with a coolingcapacity of 0.8 to 4.5 kW, with tank and pump.Space-saving and reliable.

LWK - Air-type water recooler without refrigerationsystem with a cooling capacity of 2 to 2.5 kW,with tank and pump. The low-cost alternative forapplications with higher water operatingtemperatures.

SVK - Water chiller with a cooling capacity of15 to 70 kW, with tank and pump. Compactdesign with high temperature accuracy.

Page 6: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

Basket evaporator

Competence and Experience in Industrial Cooling Systems

Temperatures

All standard machines are specified for a maximum ambient temperature of + 37° C.*) Machines for + 42° C maximum ambient temperature are available at extra cost. Machine sizes will not change.

VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK20/1 30/1 50/1 70/1 90/1 110/1 140/1 180/1 220/1 270/1 320/1 360/1 440/1 540/1 640/1

Ambient air Water Cooling capacities in kW

10° C 1,9 3,2 5,2 6,6 9,7 11,8 14,1 16,9 21,4 25,7 31,4 33,9 42,9 51,4 62,9

32° C 15° C 2,4 4,0 6,2 7,8 11,5 13,9 16,6 20,0 25,3 29,9 37,0 40,0 50,7 59,9 74,1

20° C 2,7 4,5 6,9 8,7 12,6 15,4 18,3 21,7 28,0 33,5 41,5 43,5 56,0 67,1 83,1

10° C 1,8 2,8 5,1 6,0 9,1 10,9 13,1 16,7 20,2 23,9 29,6 33,4 40,5 47,9 59,2

37° C 15° C 2,5 3,6 6,1 7,2 10,7 13,0 15,7 20,0 23,9 28,2 34,9 40,0 47,8 56,5 69,8

20° C 2,6 4,1 6,7 7,9 11,8 14,4 17,2 21,7 25,6 31,1 37,9 43,5 51,3 62,4 75,9

10° C 1,7 3,2 4,7 5,9 8,7 9,1 12,9 15,6 19,6 22,9 25,0 31,4 39,3 45,8 50,0

42°C 15° C 2,1 3,4 5,7 7,1 10,2 11,4 15,4 18,5 23,5 27,4 30,9 37,0 47,1 54,9 61,9

20° C 2,6 3,9 6,4 7,9 11,2 13,0 17,0 20,4 25,6 30,2 35,0 40,9 51,3 60,6 70,0

VWK water chiller

Standard equipment:� Water control

� Stainless steel frame

� Stainless steel coil evaporator

� Chiller IP 54

� Operating temp. 37° C max. ambient

� High tech scoll compressor / low noise

� High efficiency air cooled condensator

� Digital thermostat hysteresis +/- 1,0 K

� Refrigerant circuit with TÜV approved low and high

pressure switch

� By-Pass valve

� Draining through water level control

� All systems with control transformer.

no neutral required

� Environment friendly refridgerant R407C

� CH-pump with carbide / carbide shaft seal

� Panels in RAL colour on request

Options:� DC voltage - control circuit

� Drain valve for tank

� Water outlet manometer

� Water level switch for pump-protection

� Winter start up regulation (0-50-100%)

� Common alarm (potential free)

� Special voltage

� Flow switch

� Common alarm (potential free)

� Water set point +40° C max.

� Hand shut off valve between

tank and pump

� Wire labelling

� Harting connectors / plugs

� Refrigerant R 134 A

� Non return valve + magnetic valve

� Hysteresis +/- 0,3 K

� Air filter

� Stop process with low/high temperature alarm

� CR-pump for pressure above 3 bar with

carbide / carbide shaft seal

� Stainless steel piping

� Operating temperature > 37° C ambient

Technical date

Cooling capacities

SpecificationsVWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK20/1 30/1 50/1 70/1 90/1 110/1 140/1 180/1 220/1 270/1 320/1 360/1 440/1 540/1 640/1

Number of Scroll-compressors 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2

Power consumptioncompressor max. kW 1,4 2,0 2,6 3,1 4,3 5,9 6,2 7,9 9,7 11,1 15,5 15,8 19,4 22,2 31,0

Power consumptionmax. kW 2,6 3,4 4,0 4,7 6,1 7,9 8,9 10,6 12,4 14,2 18,9 21,2 24,8 28,4 37,2

Currentmax. A 4,8 6,2 7,1 8,1 10,6 13,9 15,4 18,7 21,3 25,0 32,2 37,7 42,9 50,3 63,1

Air flow rate max. m3/h 2800 4500 4500 4500 5500 6100 9300 9300 9300 11000 12600 18600 18600 22000 25200

Water tank volume ltr. 90 90 90 120 120 120 300 300 300 300 300 500 500 500 500

Water pressure bar 3,4 3,4 3,4 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 4,0 4,0 4,0 4,0

Nominal water flow m3/h 1,5 1,5 1,5 2,0 2,0 2,0 3,5 3,5 3,5 3,5 3,5 8,0 8,0 8,0 8,0

Water connectioninlet / outlet inch 3/4 374 3/4 3/4 3/4 3/4 1 1 1 1 1 2 2 2 2

Water connectionsfeed inch 3/4 374 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4

Length (L) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 2000 2000 2000 2000

Width (B) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 1000 1000 1000 1000

Height (H) mm 1375 1375 1375 1375 1375 1375 2000 2000 2000 2000 2000 2000 2000 2000 2000

Weight (approx.) kg 170 170 180 190 200 200 320 370 400 400 410 740 800 800 810

Power supply 3/PE/400 V/50 Hz. Control voltage 24 V AC. All technical data is valid for machines with a maximum ambient temperature of + 42° C.

Specifications subject to change.

Page 7: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

VWK-DShell & Tubes Chiller

Plug-in plug-out water chillerCooling capacity from 2 to 70 kW

®

Competence and experience in industrial cooling systems

VWK

SVK

TRK

CHILLY

LWK

Special

VWKDesk Unit

DIN EN ISO 9001Zertifikat: 09 100 5300

VWKShell & Tubes

Product range

HYFRA Industriekühlanlagen GmbHIndustriepark 54 · D-56593 KrunkelPhone: +49 (0) 26 87 / 8 98-0 · Fax: +49 (0) 26 87 / 8 98-25 · eMail: [email protected]

www.hyfra-pedia.com

In addition to our standard product range, we offer you solutions for liquid cooling in allindustrial applications.Our systems are available in compact or split design, air or water cooled.Continuous-flow recoolers and expansions with cleanable plate-type heat exchangers arejust as available as versions with special voltages.Our sales team of engineers and technicians is always available to you for comprehensiveconsultation. Do not hesitate, we are awaiting your enquiry!

TRK - Immersion chiller for cooling lubricantswith a cooling capacity of 2 to 70 kW.Service-friendly in maintenance and cleaning.

CHILLY - cooling-water chiller with a coolingcapacity of 0.8 to 4.5 kW, with tank and pump.Space-saving and reliable.

LWK - Air-type water recooler without refrigerationsystem with a cooling capacity of 2 to 2.5 kW,with tank and pump. The low-cost alternative forapplications with higher water operating.temperatures.

SVK - Water chiller with a cooling capacity of15 to 130 kW, with tank and pump. Compactdesign with high temperature accuracy.

Page 8: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

Shell & Tubes evaporator

Temperature

VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK20-DE 30-DE 50-DE 70-DE 90-DE 110-DE 140-DE 180-DE 220-DE 270-DE 320-DE 360-DE 440-DE 540-DE 640-DE

Number of Scroll-compressors 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2

Power consumptioncompressor max. kW 2,0 2,0 2,6 3,1 4,3 5,9 6,2 7,9 9,7 11,1 14,6 15,6 19,4 22,2 29,2

Power consumptionmax. kW 2,9 3,0 3,8 4,1 5,5 7,5 7,9 10,1 11,9 13,3 17,4 19,7 23,3 26,1 34,4

Currentmax. A 5,6 5,6 7,0 7,4 9,9 13,4 13,7 17,9 20,5 22,9 29,5 34,8 40,0 44,8 58,0

Air flow rate max. m3/h 2300 2800 4500 2600 4300 5500 5800 9300 9300 9300 11000 18600 18600 18600 22000

Pump inlet pressure m 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5

Fluid pressure bar 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0

Nominal fluid flow m3/h 3,5 3,5 3,5 3,5 3,5 3,5 6,5 6,5 6,5 6,5 6,5 13,0 13,0 13,0 13,0

Pump type Grundfos CH 4-20 CH 4-20 CH 4-20 CH 4-20 CH 4-20 CH 4-20 CH 8-20 CH 8-20 CH 8-20 CH 8-20 CH 8-20 CH 12-20 CH 12-20 CH 12-20 CH 12-20

Fluid connectioninlet/outlet inch 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 2

Length (L) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 2000 2000 2000 2000

Width (B) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 1000 1000 1000 1000

Height (H) mm 1375 1375 1375 1375 1375 1375 2000 2000 2000 2000 2000 2000 2000 2000 2000

Weight (approx.) kg 170 170 180 180 200 200 320 370 400 400 410 740 800 800 810

Power supply 3/PE/400 V/50 Hz. Control voltage 24 V AC. All technical data is valid for machines with a maximum ambient temperature of + 42° C.

Competence and experience in industrial cooling systems

Specification for oilVWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK

20-DÖ 30-DÖ 50-DÖ 70-DÖ 90-DÖ 110-DÖ 140-DÖ 180-DÖ 220-DÖ 270-DÖ 320-DÖ 360-DÖ 440-DÖ 540-DÖ 640-DÖNumber of Scroll-compressors 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2

Power consumptioncompressor max. kW 2,0 2,0 2,6 3,1 4,3 5,9 6,2 7,9 9,7 11,1 14,6 15,6 19,4 22,2 29,2

Power consumptionmax. kW 3,0 3,2 4,0 4,3 5,7 7,6 8,0 10,1 11,9 13,3 17,5 20,7 24,3 27,1 35,4

Currentmax. A 5,8 5,9 7,2 7,7 10,1 13,6 14,2 18,4 21,0 23,4 30,0 37,4 42,6 47,4 60,6

Air flow rate max. m3/h 2300 2800 4500 2600 4300 5500 5800 9300 9300 9300 11000 18600 18600 18600 22000

Pump inlet pressure m 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5

Fluid pressure bar 1,5 1,5 1,5 1,5 1,5 1,5 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0

Nominal fluid flow m3/h 5,0 5,0 5,0 5,0 5,0 5,0 10,0 10,0 10,0 10,0 10,0 20,0 20,0 20,0 20,0

Pump type Grundfos CR 5-4 CR 5-4 CR 5-4 CR 5-4 CR 5-4 CR 5-4 CR 8-20 CR 8-20 CR 8-20 CR 8-20 CR 8-20 CR 32-1 CR 32-1 CR 32-1 CR 32-1

Fluid connections inlet/outlet inch 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 2 2 3 3 3 3

Length (L) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 2000 2000 2000 2000

Width (B) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 1000 1000 1000 1000

Height (H) mm 1375 1375 1375 1375 1375 1375 2000 2000 2000 2000 2000 2000 2000 2000 2000

Weight (approx.) kg 170 170 180 180 200 200 320 370 400 400 410 740 800 800 810

Power supply 3/PE/400 V/50 Hz. Control voltage 24 V AC. All technical data is valid for machines with a maximum ambient temperature of + 42° C.Specifications subject to change.Viscosity: max 100 mm2/s

VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK VWK

20-D 30-D 50-D 70-D 90-D 110-D 140-D 180-D 220-D 270-D 320-D 360-D 440-D 540-D 640-D

Ambient air Emulsion Oil Cooling capacities in kW

10° C 15° C 1,9 3,2 5,2 6,6 9,7 11,8 14,1 17,6 22,1 26,4 32,1 35,3 44,3 52,8 64,3

32° C 15° C 20° C 2,4 4,0 6,2 7,8 11,5 13,9 16,6 20,0 25,3 29,9 37,0 40,0 50,7 59,9 74,1

20° C 25° C 2,7 4,5 6,9 8,7 12,6 15,4 18,3 21,7 28,0 33,5 41,5 43,5 56,0 67,1 83,1

10° C 15° C 1,8 2,8 5,1 6,0 9,1 10,9 13,1 16,7 20,2 23,9 29,6 33,4 40,5 47,9 59,2

37° C 15° C 20° C 2,5 3,6 6,1 7,2 10,7 13,0 15,7 20,0 23,9 28,2 34,9 40,0 47,8 56,5 69,8

20° C 25° C 3,02,6 4,1 6,7 7,9 11,8 14,4 17,2 21,7 25,6 31,1 37,9 43,5 51,3 62,4 75,9

10° C 15° C 1,7 3,2 4,7 5,9 8,7 9,1 12,9 15,6 19,6 22,9 25,0 31,4 39,3 45,8 50,0

42°C 15° C 20° C 2,1 3,4 5,7 7,1 10,2 11,4 15,4 18,5 23,5 27,4 30,9 37,0 47,1 54,9 61,9

20° C 25° C 2,6 3,9 6,4 7,9 11,2 13,0 17,0 20,4 25,6 30,2 35,0 40,9 51,3 60,6 70,0

All standard machines are specified for a maximum ambient temperature of + 37° C.*) Machines for + 42° C maximum ambient temperature are available at extra cost.Machine sizes will not change.

VWK Shell & Tubes Chiller

Standard equipment:

� Emulsion / oil cooling

� Stainless steel frame

� Copper-nickel plated evaporator

� Chiller IP 54

� Operating temp. 37° C ambient

� High tech scroll compressor / low noise

� High efficiency air cooled condenser

� Digital thermostat hysteresis +/- 1,0 K

� Refrigerant circuit with TÜV approved low and highpressure switch

� All systems with control transformer,no neutral required

� Environment friendly refrigerant R407C

� CH-pump with carbide / carbide shaft seal

� CR-pump with carbide / carbide shaft sealfor oil

� Panels in RAL paint upon request

� Flow switch

� Antifreeze thermostat

� Easy cleanable evaporator

Options:

� DC voltage - control circuit

� Fluid outlet manometer

� Winter start up regulation (0-50-100%)

� Special voltage

� By-Pass valve

� Centrifugal fan for high air pressure

� Common alarm (potential free)

� Fluid set point +40° C max.

� Shut off valves (inlet/outlet)

� Wire labeling

� Harting connectors / plugs

� Refrigerant R 134 A

� Hysteresis +/- 0,3 K

� Air filter

� Stop process with low/high temperature alarm

� Operating temperature > 37° C ambient

� Gear pump

Technical data

Cooling capacities

Specification for emulsion

Page 9: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

CHILLYIndustrial Compact Water Chiller

Plug-in water chillers.Cooling Capacity from 0,8 bis 4,5 kW

®

Competence and Experience in Industrial Cooling Systems

VWK

SVK

TRK

CHILLY

LWK

Special

VWKDesk Unit

VWKShell & Tubes

DIN EN ISO 9001Zertifikat: 09 100 5300

Product range

HYFRA Industriekühlanlagen GmbHIndustriepark 54 · D-56593 KrunkelPhone: +49 (0) 26 87 / 8 98-0 · Fax: +49 (0) 26 87 / 8 98-25 · E-mail:[email protected]

www.hyfra-pedia.com

In addition to our standard product range, we offer you solutions for liquid cooling in allindustrial applications.Our systems are available in compact or split design, air or water cooled.Continuous-flow recoolers and expansions with cleanable plate-type heat exchangers arejust as available as versions with special voltages.Our sales team of engineers and technicians is always available to you for comprehensiveconsultation. Do not hesitate, we are awaiting your enquiry!

VWK/1 - Water chiller with a cooling capacityof 2 to 15 kW, with tank and pump. Compactdesign with high temperature accuracy.

TRK - Immersion chiller for cooling lubricantswith a cooling capacity of 2 to 75 kW.Service-friendly in maintenance and cleaning.

LWK - Air-type water recooler without refrigerationsystem with a cooling capacity of 2 to 2.5 kW,with tank and pump. The low-cost alternative forapplications with higher water operatingtemperatures.

SVK - Water chiller with a cooling capacity of15 to 70 kW, with tank and pump. Compactdesign with high temperature accuracy.

Page 10: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

Temperatures

Competence and Experience in Industrial Cooling Systems

(1) Freefield measurement at 1,0 m distance

Specifications subject to change

Chilly 08 Chilly 15 Chilly 25 Chilly 35 Chilly 45

Ambient air Water Cooling capacities in Watt

10 530 920 2100 2740 3750

32° C 15 775 1290 2450 3565 4525

20 1025 1655 2810 4395 5480

10 345 675 1645 2240 3450

37° C 15 615 1050 2060 3080 4395

20 890 1425 2475 3920 5340

10 205 450 1390 1740 3045

42° C 15 480 765 1810 2580 3870

20 755 1085 2230 3420 4690

Chilly 08 Chilly 15 Chilly 25 Chilly 35 Chilly 45

Refrigerant R 407 c environment friendly

Power consumptioncompressor max. kW 0,56 0,83 1,31 1,64 2,08

Power consumptionmax. kW 0,71 1,11 1,59 2,52 2,98

Currentmax. A 5,1 5,9 10,0 12,3 13,3

Power supply V/PH/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Air flow rate max. m3/h 914 1210 1020 2300 2200

Water tank volume ltr. 18 18 18 30 30

Water flow l/min. 2,3 4,3 7,2 10,0 12,9

Water pressure bar (g) 2,2 3,6 2,9 2,6 2,3

Water connectioninlet / outlet Zoll 3/8 3/8 3/8 3/8 3/8

Sound pressure (1) dB (A) 62,2 63,6 64,8 71,7 69,8

Length (L) mm 705 705 705 755 755

Width (B) mm 510 510 510 600 600

Height (H) mm 450 450 450 500 500

Weight (approx.)without water kg 49 55 65 81 90

CHILLY Compact Water Chiller

Standard equipment:� Waterlevel control outside

� Stainless steel coil evaporator

� High tech. scroll compressor / low noise

� High efficiency air cooled condensor

� Digital thermostat hysteresis +/- 1,0 K

� Refrigerant circuit with TÜV approved

high pressure switch

� Chiller IP 44

� Operating temperature max. 42° C ambient

� Plastic water tank

� Draining through water level control

� Environment friendly refridgerant R 407 c

� Internal by-pass for pump protection

� Non ferrous water circuit

� CE-Standard / ISO 9001 / EN 60204

� Grundfos/Speck pumps

� Water connection quick cuppling

Options:� Water outlet manometer

� Waterlevel switch for

pump-protection

� Common alarm (potetial free)

� 2 x water inlet / outlet

� Special voltage

� Flow switch

� Autom. fresh water supply

� By-Pass valve

� Non return valve + magnetic valve

Technical data

Cooling capacities

Specifications

Page 11: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

Zertifiziert nach DIN EN ISO 9001 : 2000

BETRIEBSANLEITUNG

OPERATING INSTRUCTIONS

INSTRUCTIONS DE SERVICE

YOUR PARTNER IN PROCESS COOLING

Page 12: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

Operating instructions

Hyfra-Industriekühlanlagen Industriepark 54 56593 Krunkel

Machine identification Type: LWK Important: These operating instructions have to be read carefully before putting the refrigerating plant into operation. The manufacturer can`t undertake any liability for damage or operating trouble resulting from the non-observance of these operating instructions. All rights for technical modification required for further development are reserved.

Proper use of the refrigerating plant The refrigerating plant is designed for the cooling of water. In case you intend to use other agents (e.g. deionised water) please contact the manufacturer. Limits indicated in the technical data must not be exceeded. Use of the plant to cool flammable or explosive substances is prohibited.

Please keep these operating instructions for further use!

Page 13: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

Table of contents:

Chapters

1 SAFETY/ PREVENTION OF ACCIDENTS 2

2 TRANSPORT 5

3 INSTALLATION AND INITIAL OPERATION 6

4 MAINTENANCE 8

5 STRUCTURE AND OPERATION 9

Page 14: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

1 Safety / Prevention of accidents 1.1 General information

This manual contains basic information which has to be observed during initial start, operation and maintenance. Therefore these operating instructions are to be read by the installer or personnel in charge before putting the plant into operation. This manual must be available whereever the plant is operated.

Any general safety instructions mentioned in this chapter as well as those given in other sections of this manual have to be observed.

1.2 Qualification of personnel and training Operating, maintenance, inspection and installation personnel must be properly qualified for their work. Range of possibility, competence and supervision of the personnel must be determined by the operator.

1.3 Danger due to non-observance of safety instructions Non-observance of safety instructions may cause injuries, endanger the environment or damage the unit. Non-observance of safety instructions will result in the loss of right to claim for any damages.

1.4 Safe performance of work Any safety instructions given in this manual, including national regulations on accident prevention as well as any possible internal working, operating and safety instructions have to be observed.

1.5 Safety instructions for plant and operator

Protective guards that have been installed to prevent contact with moving parts may not be removed when the unit is being operated. Danger from electric energy must be excluded. (→ See VDE regulations of the local power supply companies for detailed information)

1.6 Safety instructions on maintenance, inspection and installation work Basically non of the cleaning or maintenance tasks may be performed until the unit has come to a complete stop. The shutdown procedure as described in this manual must be observed. As soon as this work has been carried out, all safety devices and protective equipment must be mounted or installed according to their proper function.

1.7 Arbitrary modification and production of spare parts The unit may be converted only if an agreement with the manufacturer has been reached. Original spare parts and accessories accepted by the manufacturer serve as safety devices. In case any other parts are used the liability for therefrom resulting trouble may be canceled.

1.8 Unacceptable operating methods The operational safety of the delivered unit is guaranteed only if the unit is properly used as intended. Limits indicated in the technical data must not be exceeded.

Page 15: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

1.9 Safety symbols 1.9.1 Warning

!

This symbol is included next to all the safety instructions involving work that may result in serious injuries. Observe these instructions and act with extreme caution in such instances. Inform all other users as well. In addition to the instructions included in this manual the general safety and accident prevention regulations must also be taken into account.

1.9.2 Attention

This symbol is included next to the items in this manual that must be strictly observed to ensure proper application of the guidelines, regulations, instructions and procedure of tasks and that the machine or other parts are not damaged or destroyed.

1.9.3 Note

This refrigerating plant is designed according to state-of-the-art technology and is operationally reliable. Dangerous situations may, however, arise if the unit is used by personnel without proper training or if it is not used correctly according to its intended purpose. Accordingly, this may affect efficient operation of the unit.

Page 16: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

2 Transport The refirgerating plant may only be transported in the original packaging to the site of initial operation. In case of damage supplier must be informed immediately. If the unit is moved to another location within a factory, all connections must be disconnected from the unit. Moving the unit to another location must be checked by an expert and repaired as required before it is put into operation again.

!

When transporting the unit, consider the weight indicated in the technical data. Use means of transportation with the corresponding minimum load capacity.

Page 17: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

3 Installation and initial start

3.1 Set up

When setting up the refrigerating plant please observe strictly the following points:

• Assure that the required cooling air can be sucked in (see technical data). • The distance to buildings hindering the air inlet or outlet has to be at least 0,5 m. • The unit must not be set up next to a heater. • Due to intensive generation of heat, the unit must not be set up in the

immediate reach of a workplace. • The unit must be set up on level, solid surfaces only, so that stability is

ensured.

3.2 Electric supply

The refrigerating plants of series LWK are equipped with a mains plug. Mains voltage is 1/N/PE AC 50 Hz 230 V +6/-10 %.

3.3 Connection of the consumer

The unit to be cooled must be connected with the water-cooled air cooler by means of hose pipes. Out- Inlet are to be installed according to their marking. Before starting up the pump must be filled with the pumping medium and deaerated.

3.4 Refill of the store tank

A filler neck is provided at the casing box. 3.5 Putting the refrigerating plant into operation

After the tank has been filled with water the unit can be put into operation by means of the plug.

Page 18: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

The water-cooled air cooler must be switched on before the unit to be cooled. In this manner any non-permissible rise in temperature of the medium is avoided.

Switching on the pump for the first time makes water level in tank sink. Any loss in water must be refilled.

The operator has to ensure that only authorized personnel works at the refrigerating plant.

3.6 Non permissible operating states and working methods

Since the pump of series LWK is not protected by a bypass valve, the flowing-through on the consumer’s side must not be throttled on zero. The water level of the tank can be lowered after some time according to possible leaks. Dry-running of the pump can damage the pump. Therefore the water level of the tank has to be checked everyday and water refilled if necessary.

Non-observance of these instructions may lead to premature defect of the pump.

Page 19: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

4 Maintenance

4.1 Inspection 4.1.1 General information

In case of irregularities during operation of mechanically-working aggregates or extraneous noise the refrigerating plant must be switched off.

4.1.2 Medium to be cooled • Cleanness control of the medium to be cooled must be checked everyday. In

case of need let off the medium, rinse and refill the cooling circuit. The pump has to be cleaned in this case.

• Check water level of the tank daily and refill water if necessary.

4.2 Cleaning of condenser

• Make sure that lamellas of the condenser remain clean in order to guarantee required heat exchange. As demanded by ambience conditions lamellas of condenser should be cleaned in determined time intervals. Dust and fluffing e.g. may be removed by means of compressed air.

4.3 Standstill for prolonged period

In case of longer standstill of the refrigerating plant, it is advisable to empty water circuit completely. For renewed start-up of refrigerating plant make the same controls as for the initial start-up.

Page 20: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

5 Structure and operation

1

2

3

4

5

6

71 Outlet2 Inlet3 Heat exchanger4 Tank VA 1.43015 Water bib6 Pump7 Paddle

The cooling water is sucked out of the tank (4) by means of the pump (1) and transported to the consumers. Warm water flowing back from the consumers is cooled in the heat exchanger (3). The plants of series LWK are air-cooled water coolers which means that the temperature of water flowing back into the tank is about 10 °C above ambient temperature. Pump (6) and paddle (7) are run by the same engine.

Page 21: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

XS1 L N

X1 PE

PE M3

X1 PE

circuit diagram principal circuitsmain circuit schema de circuits

Netz :mains :courant :max Vorsicherung :max. fuse :calibrage max. des fusibles :Anschlussleistung :connected load :puissance max :max. Betriebsstrom :operation current :intensite max. :

10A

0,35kW

3,1A

1/N/PE 50/60Hz 230V

Pumpepump

Einspeisungpower supply

A

B

2 3 4 5 6 7 81

1E0003236LWK

HauptstromkreiseMain circuit 1Zust. Änderung Datum Name

DatumBearb.Gepr.Norm Ursp. Ers. f. Ers. d.

Zeichng.Nr.

Typ

=+

BlattBlattvon

A

B

C

D

F

A

B

C

D

E

F

2 3 4 5 6 7 8

E

1

Bruchhof10.6.2005

Lacher

Page 22: Product range - Al Mishkaattechsystem.pl/old/dostawcy/hyfra/kat/eng_hyfra.pdf · In addition to our standard product range, we offer you solutions for liquid cooling in all industrial

PRODUKT-ÜBERSICHT

O V E R V I E W

P R O S P E C T U S


Recommended