Products andsolutions for power factorcorrection
100% electricity
Tra ditionand Innovation
www.LovatoElectric.com
LOVATO Electric S.p.A. - Bergamo - Italy
Since 1922
Italian design
Most advanced manufacturing facilities
Quality and certifications
Customer care service
International presence in over 100 countries
The Customer Service team offers prompt andprofessional assistance for products andapplications.
Highly-qualified design, technical and research staff fully developand design innovative and reliable products in the Bergamooffices, using state-of-the-art software.
The first LOVATO Electric headquarters founded in Bergamoin 1922: the starting point of the grand industrial adventure.
LOVATO Electric manufactures its productswith cutting-edge technology.
LOVATO Electric products comply with the majorinternational quality standard requirements.
Eight foreign branches and widespread official sales affiliates assureproduct assistance and availability in over 100 countries worldwide.
United KingdomLOVATO (UK) LTD
Czech RepublicLOVATO S.R.O.
Germany DELTEC LOVATO GmbH
USALOVATO ELECTRIC INC
SpainLOVATO ELECTRIC S.L.U.
CanadaLOVATO ELECTRICCORPORATION
PolandLOVATO ELECTRIC SP. Z O.O.
MexicoLOVATO ELECTRICDE MEXICO, S.A. DE C.V.
P R O D U C T S A N D S O L
Switchdisconnectors
Contactors
Fuseholders
Fuse holders
Automaticpower factor controllers
Current transformers
L1
L2
L3
P R O D U C T S A N D S O L
U T I O N S F O R P O W E R F
CONTACTORS
MEASURING INSTRUMENTS
Digital voltmeters, ammeters,wattmeters, frequency meters andcosphi meters Digital expandable multimeters withgraphic LCD Connection for single, two and threephase systems Totally programmable digital outputs RS485, RS232, USB, Ethernetcommunication interface forremote control and data logging.
CURRENT TRANSFORMERS
Primary current: 40-4000A Solid and split core versions Secondary current: 5A.
SWITCH DISCONNECTORS
16A to 1600A ratings Three and four pole types and withfuseholder Versions: direct operating, door couplingand in housing Wide range of accessories.
U T I O N S F O R P O W E R F
PROTECTION RELAYS
Modular versions, also for 35mm DINrail fixing
Minimum and maximum voltagemonitoring relays for single and threephase systems, with or without neutral
Voltage monitoring relays for asymmetry,phase loss and phase sequence control
Minimum and maximum currentmonitoring relays
Frequency monitoring relays Phase shift control relays.
7.5 - 12.5 - 15 - 20 - 25 - 30 - 38 - 45 - 50 -60kVAR ratings at 400V Versions with incorporated limitingresistors Three-pole types up to 630A in AC3 duty Four-pole types up to 1600A in AC1 duty Wide range of accessories
AUTOMATIC POWER FACTOR CONTROLLERS
DCRK SERIES• Digital programming• 5 or 7 steps (96x96mm housing)• 8 or 12 steps (144x144mm houing)• Capacitor overload
protection • Internal panel temperature sensor • TTL/RS232 programming interface• Automatic set-up function• Configurable alarms.
DCRJ SERIES• Digital programming• 8 or 12 steps (144x144mm housing)• Dual display• Independent voltage
measurement input • Capacitor overload protection• Internal-external panel temperature sensor • RS232 programming and supervision
interface • RS485 supervision interface • Voltage and current harmonic
measurement • Event log • Automatic set-up function• Configurable alarms • Suitable for medium-voltage systems.
DCRJ12F TYPE (static outputs)• Digital programming• 11 steps plus 1 alarm output (144x144mm housing)• Dual display• Independent voltage
measurement input • Capacitor overload protection • Internal-external panel temperature sensor • RS232 programming and supervision
interface • RS485 supervision interface • Voltage and current harmonic
measurements • Event log• Configurable alarms• Real Time Reaction to load variations
(40…60ms )• Configuration with combined static and
electromechanical steps.
FUSE HOLDERS
Modular concept for 10x38, 14x51 and22x58 fuse sizes IP20 protection degree, finger safe andsealable cover to increase user’s safety Version with status indicator to quicklyidentify the fuse to replace UL and CSA certified versions.
F A C T O R C O R R E C T I O N
SET-UP AND REMOTE CONTROL SOFTWARE
For DCRK, DCRJ and DCRFJ12F controllers Installation operation control
• Graphic and numerical viewing of measurements • Controller status • Virtual front panel • For each step: function - state.
Capacitor efficiency control • Current kVAR measurement of each step • Counter for number of connections for each step • Hour counter register for total connection time of each step.
Access to all set-up parameters in 4 languages It is possible to: • Save, upload, print the parameters • Verify the changed parameter values • Restore default values.
Customising of alarm properties • Alarm enabling • Alarm relay activing • Disconnection of steps • Alarm delay time.
Automatic testing of electric panel.
DCRJ-DCRJ12F SOFTWARE
Data collection (data logging) Event recording GSM modem support with SMS or email
messaging "AUTOCALL" function for automatic PC
connection
A C T O R C O R R E C T I O N
Viewing in graphic format • Programmed values • Harmonic spectrums • Recorded events.
PD7
GB 0
7 11
LOVATO Electric office in the world
LOVATO ELECTRIC S.P.A.CONTROL SOLUTIONS FOR INDUSTRYVIA DON E. MAZZA, 12 - 24020 GORLE (BERGAMO) ITALYTel. +39 035 4282111 Fax +39 035 4282200Email: [email protected] Sales Department: Tel. +39 035 4282354 - Fax +39 035 4282400
United KingdomLOVATO (UK) LTDTel. +44 8458 110023www.Lovato.co.uk
Czech RepublicLOVATO S.R.O.Tel. +420 382 265482www.LovatoElectric.cz
Germany DELTEC LOVATO GmbHTel. +49 7237 1733www.DeltecLovato.de
USALOVATO ELECTRIC INCTel. +1 757 545 4700www.LovatoUsa.com
SpainLOVATO ELECTRIC S.L.U.Tel. +34 93 7812016www.LovatoElectric.es
CanadaLOVATO ELECTRICCORPORATIONTel. +1 450 681 9200www.Lovato.ca
Poland LOVATO ELECTRIC SP. Z O.O.Tel. +48 71 7979010www.LovatoElectric.pl
MexicoLOVATO ELECTRICDE MEXICO, S.A. DE C.V.Tel. +52 555 3415662www.LovatoElectric.com.mx
Present in over 100 countries
www.LovatoElectric.com
The products described in this publication are subject to be revised or improved at any moment. Catalogue descriptions and details, such as technical and operational data, drawings and instructions, etc., do not have any contractual value. In addition, products should be installed and used by qualified personnel and in compliance with the regulations in force for electrical systems in order to avoid damages and safety hazards.
Sinc