Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle Course January 25 – 27, 2017 Y A N N I V E R S A R Y
Transcript
Page 1: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

HostProf. Beat Hintermann and international faculty

VenueAMTS, Muttenz, Switzerland

Program

OrthoDays 2017 International Foot and Ankle Course January 25 – 27, 2017

YANNIVERSARY

Page 2: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

Welcome Message

Yes, it is true. The next year’s foot course will be the 20th course! Again it will be held at the new AMTS (Academy for Medical Training and Simulation) in Muttenz, Switzerland, between the 25th and 27th of January 2017. Our adapted program includes a special symposium about the breakthroughs in foot and ankle surgery of the last years. The practical exercises will still be a main part of the course, but organized differently than last year. There will be a video symposium on current surgical techniques. An industrial exhibition rounds off the high-quality event.

New ideas, new faces and a new course format await you during the OrthoDays 2017. Superb educational opportunities – the latest in products and services – networking with colleagues – seeing old friends and making new acquaintances. The approach with two full-day practical exercises in the Wet Lab will ensure a high exchange of knowledge and expertise and it will enlarge your skills in foot and ankle surgery. Case discussions with experts will be stimulating and groundbreaking. We encourage you to participate actively and to share your thoughts and experiences. An outstanding international faculty welcomes you to share this unique opportunity with us.

We hope for a once in a life time experience for all.

Prof. Beat Hintermann

Patronage/ProgramProf. Beat HintermannStiftung zur Förderung der orthopädischen Chirurgie und Biomechanik am Fuss und Sprunggelenk, Lautengartenstrasse 14, CH-4052 Basel, [email protected]

Organization/Registrationconidea GmbH, Waldheimstrasse 22, 3604 Thun, SwitzerlandT: +41 33 335 02 79, [email protected]

YANNIVERSARY

■ Can be used as an augmentation to your Brostrom procedure

■ Immediate stabilization to allow for aggressive early rehabilitation

■ Used in acute and chronic ankle sprains

■Offers resistance against future injury

SwiveLock® anchors 4.75 mm and 3.5 mm with FiberTape®

Internal Brace™Ligament Repair Augmentation Kit

© Arthrex GmbH, 2016. All rights reserved.www.arthrex.com

AD2-80012-EN_A_InternalBrace_Foot_148x210mm.indd 1 14.09.16 16:05

OrthoDays 2017 International Foot and Ankle Course

Page 3: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

OrthoDays 2017 International Foot and Ankle Course

Impressions 2016

OrthoDays 2017 International Foot and Ankle Course

GE Healthcare

Aorta, Herz und Lunge in einem Scan in nur 1 Sekunde.Ohne Kompromisse: Der Revolution CT mit 160 mm Gemstone Clarity Detektor erlaubt nichtnur eine herausragende Abdeckung, sondern hat zudem die höchste zeitliche und räumlicheAufl ösung (24 ms/0,23 mm). Herz, Aorta und Lunge können in einem Scan in 1 Sekundevollständig erfasst werden – selbst bei sehr hoher Herzfrequenz, nahezu ohneAtempause und mit geringer Kontrastmittelgabe. Damit kann die Triple-rule-out-Untersuchung selbst bei schwierigen Patienten mit sicherem diagnostischenErgebnis in der Routine durchgeführt werden.

Weitere Informationen fi nden Sie unter www.gehealthcare.de

Revolution stattEvolution.

Page 4: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

www.medartis.com

• Indication-specific implants for TMT and MTP arthrodesis

• Anatomical plate designs

• TriLockPLUS – Compression and angular stable locking

• CCS 5.0 / 7.0 – Cannulated self-drilling and self-tapping compression screws of the next generation

APTUS Hallux System 2.8

NEWInnovative Solution in Elective Foot Surgery

Venues, Driving Directions, Parking

AccommodationCourtyard by Marriott BaselHardstrasse 55, 4133 PrattelnT: +41 61 827 17 17, F: +41 61 827 17 [email protected]

Driving directions and public transportationTo access the hotel, take the highway exit Pratteln. The hotel can then be reached within two minutes. From the train station it is an 8 minute walk.

ParkingThe hotel has 500 parking spaces available indoor in their parking garage and 200 parking spaces outdoor. The daily rate is CHF 30.–.

LocationAMTS Academy for Medical Training and SimulationKriegackerstrasse 100, CH-4132 Muttenz [email protected], www.amts.chThe AMTS is located in the upper three floors of the «Rennbahntowers» in Muttenz.

Public transportIf you are coming from Basel, then you can reach us with the train lines S1 and S3 or with the tram line 14 (tram stop Muttenz Zum Park).From the train station you can reach us by foot (approximately 900 m) or by bus with the lines 47 or 63 (Bus stop Muttenz Fach-hochschule).

Driving directionsIf coming from Zürich (A2) take the highway exit 6 Birsfelden / Hagnau and then follow the directions to Muttenz.If coming from Basel (A2) take the highway exit 6 Hagnau and follow H18 in direction Delémont /Muttenz. On H18 take the exit Muttenz-Süd.

OrthoDays 2017 International Foot and Ankle Course

Page 5: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

Schutz

Xarelto® – Erfahrung und Vertrauen7

Leben*1–6

fürs echte

Referenzen: 1. Patel et al. Rivaroxaban versus warfarin in nonvalvular atrial fi brillation. N Engl J Med 2011; 365:883–91. 2. Camm et al. XANTUS: a real-world, prospective, observational study of patients treated with rivaroxaban for stroke prevention in atrial fi brilation. Eur Heart J. 2016 Apr 7;37(14):1145-53. 3. Prins et al. Oral Rivaroxaban versus Standard Therapy for the Treatment of Symptomatic Venous Thromboembolism: a pooled analysis of the EINSTEIN-DVT and PE randomized studies. Thrombosis Journal 2013;11:21. 4. Ageno et al. Safety and effectiveness of oral rivaroxaban versus standard anticoagulation for the treatment of symptomatic deep-vein thrombosis (XALIA): an international, prospective, non-interventional study. Lancet Haematol. 2016 Jan;3(1):e12–21. 5. Turpie et al.: Rivaroxaban for the prevention of venous thromboembolism after hip or knee arthroplasty. Pooled analysis of four studies. Thromb Haemost. 2011;105(3):444–453. 6. Turpie et al.: A non-interventional comparison of rivaroxaban with standard of care for thromboprophylaxis after major orthopaedic surgery in 17,701 patients with propensity score adjustment. Thromb Haemost. 2014;111(1):94–102. 7. IMS Health MIDAS, Database: Monthly Sales February 2016.Gekürzte Fachinformation Xarelto® (Rivaroxaban): Direkter Faktor Xa-Inhibitor Z: Filmtabl. zu 10, 15 und 20 mg Rivaroxaban I: a) Thromboseprophylaxe bei grösseren orthopä-dischen Eingriffen a. d. unteren Extremitäten wie Hüft- und Knieprothesen. b) Behandlung von Lungenembolie (LE) und tiefer Venenthrombose (TVT) sowie Prophylaxe rezidivierender TVT und LE. c) Schlaganfallprophylaxe und Prophylaxe system. Embolien bei nicht-valvulärem Vorhoffl immern. D: a) 1x/Tag 10 mg. b) 2x/Tag 15 mg für die ersten 21 Tage, gefolgt von 20 mg 1x/Tag c) 1x/Tag 20 mg; bei Krea-Cl 15-49 ml/min: 1x/Tag 15 mg. 15 mg und 20 mg während Mahlzeit einnehmen. KI: Überempfi ndlichkeit auf Inhaltsstoffe, akute bakt. Endokarditis, klin. sign. aktive Blutungen, schw. Lebererkrankung/ Leberinsuffi zienz (LI) mit relev. erhöhtem Blutungsrisiko; leichte LI in Komb. mit Koagulopathie, dialysepfl . Niereninsuffi zienz (NI), akute gastro-intestinale (GI) Ulzera oder GI ulzerative Erkrankungen, Schwangerschaft, Stillzeit. W: Komedikation (siehe «IA»); <18 Jahre; künstl. Herzklappen; d. Hämostase beeinfl . Arzneimittel. VM: NI (Krea-Cl 15-29 ml/min) od. NI in Komb. mit Arzneimittel, die den Xarelto®-Plasmaspiegel erhöhen, erhöhtes Risiko unkontrollierter Blutungen und hämorrhag. Diathese, kurz zurück-liegender hämorrhag. Schlaganfall, intrakran. o. intrazerebr. Hämorrhagie, kürzlich aufgetretene GI Ulzera/ulzerative Erkrankungen, schwere unkontrollierte Hypertonie, vask. Retinopathie, intraspinale o. intrazerebr. Gefässanomalien, kurz zurückliegende Hirn-, Spinal-, Augen-OP, Bronchiektasie oder pulmonale Blutung in der Anamnese, Spinalanästhesie und -punktion, mind. 24 Stunden vor invasiven Verfahren/ chirurgischen Eingriffen absetzen, gleichzeitige Gabe von d. Hämostase beeinfl . Arzneimitteln. Häufi ge UAW: Blutungen, Anämie, Schwindel, Kopf-schmerz, Augenblutungen, Hämatome, Epistaxis, Hämoptysis, Nausea, Obstipation, Durchfall, Leberenzymerhöhungen (ASAT, ALAT), Pruritus, Rash, Schmerzen i. d. Extrem., Fieber, periph. Ödem, Asthenie. IA: Starke CYP 3A4 + P-gp -Inhib. (Ritonavir, Ketoconazol), starke CYP 3A4 + P-gp -Induk. (Rifampicin, Carbamazepin, Phenobarbital, Johanniskraut), d. Hämostase beeinfl . Arzneimittel. Packg.: 10 mg à 10 und 30; 15 mg und 20 mg à je 14, 28 o. 98 Filmtabl.; jew. Klinik packung 10x1 Filmtabl. (B), kassenzulässig. Für weitere Informationen siehe www.swissmedicinfo.ch. Vertrieb: Bayer (Schweiz) AG, Grubenstr. 6, 8045 Zürich. L.CH.MKT.HC.01.2016.0804-DE/FR/IT L.

CH.M

KT.H

C.04

.201

6.08

88-D

E/FR

/IT

* Prospektive Real-Life-Studien («echtes Leben») bestätigen das in den jeweiligen Phase-III-Studien gezeigte positive Nutzen-Risiko-Profil in den zugelassenen Indikationen.

Xarelto_Inserat_2016_Mai_A5_mitBeschnitt_dt.indd 1 09.05.16 09:35

Autologous Matrix Induced Chondrogenesis

Cho

ndro

-Gid

e® is

not

ava

ilabl

e in

all

mar

kets

. Ava

ilabi

lity

is s

ubje

ct to

the

regu

lato

ry o

r med

ical

pra

ctic

es th

at g

over

n in

divi

dual

mar

kets

. An innovative, biological technique for the treatment of cartilage defects in the talus, knee and hip

> A minimally invasive, effective one-step surgical technique for the treatment of chondral and osteochondral lesions larger than 1 cm2

> Based on microfracturing, the established first-line treatment

> Natural protection of the super clot through the unique bilayer structure of Chondro-Gide®

> Positive influence of Chondro-Gide® on chondrogenesis

> Straightforward, cost-efficient surgical technique

> 10 years of clinical experience

Clinical results and scientificstudies confirm the effectivenessof Chondro-Gide®, the leading collagen matrix in cartilage regeneration.

Geistlich Pharma AGBahnhofstrasse 40CH–6110 Wolhusen www.geistlich-surgery.com

Page 6: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

moves!functional treatment (ROM) –15° up to +30°

www.oped.ch | www.oped.de

OPED AGHinterbergstrasse 266330 ChamSwitzerlandPhone +41 (0) 41/748 53 35Fax +41 (0) 41/748 53 [email protected]

Wednesday, January 25th

Time Theme/Subject Speaker

08:30 Announcements B. Hintermann 08:40 Presidential welcome address SFAS N. Espinosa

Moderators N. Espinosa, B. Hintermann

08:45 Anatomy of the Medial Hindfoot J. Nunley

Practical Exercise I (cadaveric specimens)

09:05 Anatomy of the medial hindfoot J. Nunley, R. Ruiz

10:30 Coffee break

11:00 Anatomy of the Lateral Hindfoot B. Ribbans

Practical Exercise II (cadaveric specimens)

11:20 Anatomy of the lateral hindfoot B. Ribbans, M. Knupp

12:30 Lunch

ProgramOrthoDays 2017 International Foot and Ankle Course

Time Theme/Subject Speaker

Moderators C. Ortiz, C. Nery

Forefoot Disorders I

13:30 Decision making H. Trnka

Video Symposium I: How I do it?

14:00 Hallux valgus: TMT 1-fusion M. Assal14:15 Hallux valgus: Proximal osteotomies E. Wagner14:30 Hallux valgus: Distal osteotomies M. Knupp14:45 Hallux rigidus: Joint preserving surgery J. Nunley15:00 Hallux rigidus: MTP 1-fusion N. Espinosa15:15 Metatarsalgia: Metatarsal osteotomies H. Trnka

15:30 Coffee break

Practical Exercise III (cadaveric specimens)

16:00 Forefoot surgeries (under supervision of experts)

17:30 Case discussions H. Trnka

18:30 Adjourn, transfer to the hotel

YANNIVERSARY

Page 7: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

Rheinstrasse 26CH-4410 LiestalT +41 (0)61 925 25 25F +41 (0)61 925 20 [email protected]

CH-4101 BruderholzT +41 (0)61 436 36 36F +41 (0)61 436 36 [email protected]

Lochbruggstrasse 39CH-4242 LaufenT +41 (0)61 400 80 80F +41 (0)61 400 83 [email protected]

STANDORTE

www.ksbl.ch

Teamplayer!GEMEINSAM FÜR DIE REGIONIHR KANTONSSPITAL BASELLAND

KSBL_M19087_Inserat_FCB_Jahrbuch_164x215mm__08_2016.indd 1 29.08.2016 08:10:50

ProgramOrthoDays 2017 International Foot and Ankle Course

Thursday, January 26th

Time Theme/Subject Speaker

Moderators K. Wapner, H. Trnka

Anatomy of the Mid- and Forefoot 08:00 Anatomy of the midfoot K. Wapner08:20 Anatomy of the forefoot (incl. plantar plate) H. Trnka Mini-Battle08:40 Should the plantar plate be repaired? • No J. Nunley • Yes C. Nery

Practical Exercise IV (cadaveric specimens)

09:00 Plantar plate repair C. Nery09:30 Lisfranc reconstruction M. Assal

10:00 Coffee break

Laterally Unstable Foot / Varus Foot10:30 My treatment algorithm F. Krause

Video Symposium II: How I do it ?

10:50 Lateral ligament reconstruction B. Ribbans10:05 Z-osteotomy of calcaneus M. Knupp10:15 PL- to PB-tendon transfer A. Barg

Practical Exercise V (cadaveric specimens)

11:30 Lateral foot reconstruction in varus foot (under supervision of experts)

12:30 Lunch

Time Theme/Subject Speaker

Moderators M. Knupp, E. Wagner

Medially Unstable Foot / Valgus Foot13:30 My treatment algorithm E. Wagner

Video Symposium III: How I do it ?

13:50 Medial ligament reconstruction B. Hintermann14:05 FDL-transfer C. Ortiz14:15 Medial sliding osteotomy E. Wagner14:25 Lateral column lengthening osteotomy R. Ruiz14:35 Medial closing wedge osteotomy of tibia F. Krause Practical Exercise VI (cadaveric specimens)

14:45 Medial foot reconstruction in valgus foot (under supervision of experts)

16:00 Coffee break

Moderator B. Ribbans

Foot Reconstruction – Learn from the Master (Case based discussion round)

16:30 How I did this case H. Trnka16:45 How I did this case C. Ortiz 17:00 How I did this case F. Krause17:15 How I did this case N. Espinosa 17:30 How I did this case M. Assal17:45 How I did this case M. Knupp18:00 How I did this case K. Wapner18:15 How I did this case E. Wagner 18:30 How I did this case C. Nery

18:45 Adjourn, transfer to the hotel20:00 Get-together Hotel Marriot

YANNIVERSARY

Page 8: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

Medeco-ch Sàrl Votre partenaire médical

Medeco-ch SàrlRoute de Trélex 8

1266 DuillierSuisse

...JUST CALL USSales SwitzerlandCédric Bagnoud: +41 79 434 91 60Jean-Baptiste Marçon: +41 79 231 35 38Dylan Frossard: +41 79 940 88 23

Customer service:Phone: +41 22 307 01 70 Fax: +41 22 362 11 [email protected]

FOOTMOTION Plating systems

TrueLokRing fi xation

system

And many more products...

FOOTMOTION Various screws Small and large diameters

Alians FibulaSingle use distal fi bula sterile kits

Friday, January 27th

OrthoDays 2017 International Foot and Ankle CourseProgram

Time Theme/Subject Speaker

Moderator J. Nunley

Foot Reconstruction - Learn from the Master (Case based discussion round)

13:00 My worst case H. Trnka13:15 My worst case M. Knupp13:30 My worst case K. Wapner13:45 My worst case C. Nery14:00 My worst case N. Espinosa14:15 My worst case E. Wagner14:30 My worst case M. Assal14:45 My worst case B. Hintermann15:00 My worst case M. Knupp15:15 My worst case F. Krause15:30 My worst case C. Ortiz15:45 Discussion and final Remarks B. Hintermann

16:00 Adjourn

End of the course

Time Theme/Subject Speaker

Moderators R. Ruiz, B. Hintermann

Breakthroughs in Foot and Ankle Surgery in the last 20 Years 08:00 Forefoot surgery H. Trnka08:15 Midfoot surgery K. Wapner08:30 Hindfoot (with/without peritalar) instability A. Barg08:45 Acquired flatfoot of the adult R. Ruiz09:00 Ankle osteoarthritis: joint preserving surgery M. Knupp09:20 Ankle osteoarthritis: total ankle replacement B. Hintermann09:40 Hindfoot fusion N. Espinosa10:00 20 years of education in Switzerland J. Nunley

10:30 Coffee Break Moderator K. Wapner

Case Discussions11:00 Case I – what to do ? A. Barg11:15 Case II – what to do ? C. Nery11:30 Case III – what to do ? B. Ribbans11:45 Cases from the audience Participants

12:00 Lunch

YANNIVERSARY

Page 9: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

SOMA designSOMA is Stryker’s proprietary population-based orthopaedic design and development system that applies actual data from over 15,000 CT images of bones from people around the world. The result is an implant designed for enhanced fit across a range of patients.

Low profile constructEnhanced low profile plate design comprised of Type II anodized pure titanium.3

CP screwsThe new partially threaded solid Anchorage 2 CP screws come in two diameter sizes offering a true cancellous pitch for enhanced bone purchase.

Anchorage 2 CP plates

CP screwCP screw diameter

Lengths Hole sizeCorresponding

plates

Ø3.6mm screws

20-44mmUniversal and

MTP plates

Ø4.1mm screws

20-70mmLapidus and

Midfoot plates

CP technologyCross-joint fixation with compression to simplify the surgical procedure and minimize the need for a separate, independent transverse screw

SmartLock2,4 technologyLocking screws can be angled 15° in each direction for a total range of 30°

CP screw angulation

References1. US Patent #8, 556, 946 and #9, 078, 713.2. VariAx Hand Locking Plate System Strength of SmartLock Screw Locking Mechanism Treppenhauer, Max; v. Oldenburg, Geert.3. Stryker Trauma Kiel Test Report nos. 180399AG1 and 071099MG1, 1999 and 2000.4. Licensed from Prof. D. Wolter, Hamburg, Germany.

A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: SmartLock, Anchorage 2, Stryker. All other trademarks are trademarks of their respective owners or holders.

AN-AD-1, 05-2016 Copyright © 2016 Stryker

Universal CP plate

Lapidus CP plate

MTP CP plate

Midfoot CP plate

Visit footankle.stryker.com or email [email protected]

-15˚ +15˚

30˚

25˚

30˚

15˚

Revolutionary vision.Evolutionary design.

Anchorage® 2 CPPlating System

Patented CP1 and SmartLock2,4 technologies

Population-based design for enhanced fit

Type II anodized Ti plates

Low profile design with variable angle locking

Visit footankle.stryker.com or email [email protected]

Total ankle | Nitinol implants | Screw systems | Plating systems | Intramedullary nails | External fixation systems | Biologics

SOMA designSOMA is Stryker’s proprietary population-based orthopaedic design and development system that applies actual data from over 15,000 CT images of bones from people around the world. The result is an implant designed for enhanced fit across a range of patients.

Low profile constructEnhanced low profile plate design comprised of Type II anodized pure titanium.3

CP screwsThe new partially threaded solid Anchorage 2 CP screws come in two diameter sizes offering a true cancellous pitch for enhanced bone purchase.

Anchorage 2 CP plates

CP screwCP screw diameter

Lengths Hole sizeCorresponding

plates

Ø3.6mm screws

20-44mmUniversal and

MTP plates

Ø4.1mm screws

20-70mmLapidus and

Midfoot plates

CP technologyCross-joint fixation with compression to simplify the surgical procedure and minimize the need for a separate, independent transverse screw

SmartLock2,4 technologyLocking screws can be angled 15° in each direction for a total range of 30°

CP screw angulation

References1. US Patent #8, 556, 946 and #9, 078, 713.2. VariAx Hand Locking Plate System Strength of SmartLock Screw Locking Mechanism Treppenhauer, Max; v. Oldenburg, Geert.3. Stryker Trauma Kiel Test Report nos. 180399AG1 and 071099MG1, 1999 and 2000.4. Licensed from Prof. D. Wolter, Hamburg, Germany.

A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: SmartLock, Anchorage 2, Stryker. All other trademarks are trademarks of their respective owners or holders.

AN-AD-1, 05-2016 Copyright © 2016 Stryker

Universal CP plate

Lapidus CP plate

MTP CP plate

Midfoot CP plate

Visit footankle.stryker.com or email [email protected]

-15˚ +15˚

30˚

25˚

30˚

15˚

SOMA designSOMA is Stryker’s proprietary population-based orthopaedic design and development system that applies actual data from over 15,000 CT images of bones from people around the world. The result is an implant designed for enhanced fit across a range of patients.

Low profile constructEnhanced low profile plate design comprised of Type II anodized pure titanium.3

CP screwsThe new partially threaded solid Anchorage 2 CP screws come in two diameter sizes offering a true cancellous pitch for enhanced bone purchase.

Anchorage 2 CP plates

CP screwCP screw diameter

Lengths Hole sizeCorresponding

plates

Ø3.6mm screws

20-44mmUniversal and

MTP plates

Ø4.1mm screws

20-70mmLapidus and

Midfoot plates

CP technologyCross-joint fixation with compression to simplify the surgical procedure and minimize the need for a separate, independent transverse screw

SmartLock2,4 technologyLocking screws can be angled 15° in each direction for a total range of 30°

CP screw angulation

References1. US Patent #8, 556, 946 and #9, 078, 713.2. VariAx Hand Locking Plate System Strength of SmartLock Screw Locking Mechanism Treppenhauer, Max; v. Oldenburg, Geert.3. Stryker Trauma Kiel Test Report nos. 180399AG1 and 071099MG1, 1999 and 2000.4. Licensed from Prof. D. Wolter, Hamburg, Germany.

A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: SmartLock, Anchorage 2, Stryker. All other trademarks are trademarks of their respective owners or holders.

AN-AD-1, 05-2016 Copyright © 2016 Stryker

Universal CP plate

Lapidus CP plate

MTP CP plate

Midfoot CP plate

Visit footankle.stryker.com or email [email protected]

-15˚ +15˚

30˚

25˚

30˚

15˚

SOMA designSOMA is Stryker’s proprietary population-based orthopaedic design and development system that applies actual data from over 15,000 CT images of bones from people around the world. The result is an implant designed for enhanced fit across a range of patients.

Low profile constructEnhanced low profile plate design comprised of Type II anodized pure titanium.3

CP screwsThe new partially threaded solid Anchorage 2 CP screws come in two diameter sizes offering a true cancellous pitch for enhanced bone purchase.

Anchorage 2 CP plates

CP screwCP screw diameter

Lengths Hole sizeCorresponding

plates

Ø3.6mm screws

20-44mmUniversal and

MTP plates

Ø4.1mm screws

20-70mmLapidus and

Midfoot plates

CP technologyCross-joint fixation with compression to simplify the surgical procedure and minimize the need for a separate, independent transverse screw

SmartLock2,4 technologyLocking screws can be angled 15° in each direction for a total range of 30°

CP screw angulation

References1. US Patent #8, 556, 946 and #9, 078, 713.2. VariAx Hand Locking Plate System Strength of SmartLock Screw Locking Mechanism Treppenhauer, Max; v. Oldenburg, Geert.3. Stryker Trauma Kiel Test Report nos. 180399AG1 and 071099MG1, 1999 and 2000.4. Licensed from Prof. D. Wolter, Hamburg, Germany.

A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: SmartLock, Anchorage 2, Stryker. All other trademarks are trademarks of their respective owners or holders.

AN-AD-1, 05-2016 Copyright © 2016 Stryker

Universal CP plate

Lapidus CP plate

MTP CP plate

Midfoot CP plate

Visit footankle.stryker.com or email [email protected]

-15˚ +15˚

30˚

25˚

30˚

15˚

Revolutionary vision.Evolutionary design.

Anchorage® 2 CPPlating System

Patented CP1 and SmartLock2,4 technologies

Population-based design for enhanced fit

Type II anodized Ti plates

Low profile design with variable angle locking

Visit footankle.stryker.com or email [email protected]

Total ankle | Nitinol implants | Screw systems | Plating systems | Intramedullary nails | External fixation systems | Biologics

Revolutionary vision.Evolutionary design.

Anchorage® 2 CPPlating System

Patented CP1 and SmartLock2,4 technologies

Population-based design for enhanced fit

Type II anodized Ti plates

Low profile design with variable angle locking

Visit footankle.stryker.com or email [email protected]

Total ankle | Nitinol implants | Screw systems | Plating systems | Intramedullary nails | External fixation systems | Biologics

FacultyOrthoDays 2017 International Foot and Ankle Course

Assal Mathieu, MDClinique La Colline, Av. de Beau-Séjour 6, 1206 Genève 14, [email protected]

Barg Alexej, MDDepartment of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA [email protected]

Espinosa Norman, MDSFAS President, Foot and Ankle Institute, Kappelistrasse 7, 8002 Zürich, Switzerland [email protected]

Hintermann Beat, MDOrthopaedic Department, Cantonal Hospital Baselland, 4410 Liestal, Switzerland [email protected]

Krause Fabian, MD Orthopaedic Department, University Hospital Inselspital, 3010 Bern, [email protected]

Knupp Markus, MDOrthopaedic Department, Cantonal Hospital Baselland, 4101 Bruderholz, Switzerland [email protected]

Nery Caio, MDRua Afonso Bràs 817, V.N. Concalcao Sao Paulo, Brazil [email protected]

Nunley James, MDDepartment of Orthopaedics, Duke University Medical Center, Box 2923, Durham, North Carolina 27710-0001, USA [email protected]

Ortiz Cristián, MDClinica Alemana, Vitacura, Av. Manquehue Norte 1410, Santiago de Chile, Chile [email protected]

Ribbans William J, MD, PhDUniversity of Northampton, The County Clinic, 57 Billing Road, Northampton, NN1 5DB, United Kingdom [email protected]

Ruiz Roxa, MD Orthopaedic Department, Cantonal Hospital Baselland, 4410 Liestal, Switzerland [email protected]

Trnka Hans-Jörg, MDFoot and Ankle Center Vienna, Alserstrasse 43/8D, A-1080 Vienna, Austria [email protected]

Wagner Emilio, MDClinica Alemana, Vitacura, Av. Manquehue Norte 1410, Santiago de Chile, Chile [email protected]

Wapner Keith, MDPenn Medicine, 230 West Washington Square, Philadelphia, PA 19106, [email protected]

YANNIVERSARY

Page 10: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

Partners, Exhibitors

The Conference is compliant with the Eucomed Code of Ethical Business Practice

Main-PartnerDePuy Synthes Johnson & Johnson AG, Branch Office Zuchwil, 4528 Zuchwil

Anklin AG, 4102 Binningen

Arthrex Swiss AG, 3123 Belp

Bayer (Schweiz) AG, 8045 Zürich

GE Healthcare, 8152 Glattbrugg

Geistlich Pharma AG, 6039 Root

Kantonsspital Baselland, 4410 Liestal

Künzli SwissSchuh AG, 5210 Windisch

Medartis AG, 4057 Basel

Medeco-ch Sàrl, 1266 Duillier

Oped AG, 6330 Cham

Smith&Nephew Schweiz AG, 6340 Baar

Stryker Osteonics SA, 2545 Selzach

OrthoDays 2017 International Foot and Ankle Course

YANNIVERSARY

OrthoDays 2017 International Foot and Ankle CourseOrthoDays 2017 International Foot and Ankle Course

Page 11: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

Contact: Smith & Nephew Schweiz AG | Oberneuhofstrasse 10d | 6340 Baar | 041 766 22 22 | www.smith-nephew.com04836 V1 10/15 ©2015 Smith & Nephew.

Foot and Ankle Repair Solutions

Strong. Flexible. Balanced. Complete solutions for foot and ankle surgeons.

*smith&nephew OrthoDays 2017 International Foot and Ankle Course

Fees, Credits, Registration, Accommodation

FeesFoot and Ankle Course, January 25 – 27, 2016 CHF 2500.–SFAS members CHF 2400.–

Credits16 Credits

LanguageThe Foot and Ankle course will be held in English, simultaneous translation will not be provided.

Number of Participants/RegistrationThe number of participants is limited. The registrations are accepted in the order of entrance. Please register by filling out the form at the end of this brochure or online (www.orthodays.ch). You will receive the confirmation and the invoice as an e-mail.

AccommodationHotel accommodation is not included in the course fee. If needed, accommodation needs to be booked and paid by the participants themselves. A limited number of rooms have been reserved for course participants to special rates at the Seminarhotel Courtyard by Marriott Basel.

YANNIVERSARY

Page 12: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

KARL STORZ GmbH & Co. KG, Mittelstraße 8, 78532 Tuttlingen/Germany, www.karlstorz.comAnklin AG, Baslerstrasse 9, 4102 Binningen/Schweiz, www.anklin.ch

AR

T 73

1.0

09/

2015

/A-C

H

Kraftvoll in die ZukunftDrillCut-X® ARTHRO Das neue Shaverhandstück für alle Gelenke

Ortho Tri-Phase 3 in 1 ROMmodularer Sprunggelenkschuh (modular ankle boot)

WeltneuheitAnpassbare Stabilsierung

spezifisch je Heilungsphase

Der neue Sprunggelenkschuh von Künzli: Ortho Tri-Phase Für die postoperative und konservative Therapie von Sprunggelenkverletzungen. Anpassbare Stabilisierung für den optimalen Bewegungsumfang / ROM spezifisch je Heilungsphase.

Bewegt die Heilung

Weltneuheit

Phase 1 Phase 2 Phase 3

www.kuenzli-schuhe.ch/ortho

Page 13: Program OrthoDays 2017 - Swissorthopaedics · Host Prof. Beat Hintermann and international faculty Venue AMTS, Muttenz, Switzerland Program OrthoDays 2017 International Foot and Ankle

www.depuysynthes.com

VA LOCKING CALCANEAL PLATES 2.7

© D

ePu

y Sy

nth

es C

om

pan

ies,

201

5


Recommended