+ All Categories
Home > Documents > PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1...

PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1...

Date post: 07-Sep-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
8
UP UP UP UP X X X X X X X X A B F E G 1 2 3 4 5 HA C 7 H D 1 A3.10 1 A3.10 1 A3.9 1 A3.9 WT-1D WT-5 WT-1C S03A 011A 012 013 007 008 009 011B 006 S01A 016 015 017 002 S04A 001 WT-1 WT-5 WT-5 WT-1C 14.2 m² 153.1 ft² ywca main storage 018 44.3 m² 477.2 ft² ywca bike room 1 015 9.8 m² 105.8 ft² outdoor storage 013 13.2 m² 142.2 ft² maintenance storage 012 11.7 m² 126 ft² corridor 014 16.9 m² 181.8 ft² corridor 011 13.8 m² 148.6 ft² mechanical room 006 6.6 m² 70.6 ft² comm room 007 16.6 m² 178.5 ft² electrical 008 7.9 m² 84.7 ft² i.t. 009 22.5 m² 242.6 ft² genset 001 5.5 m² 59.7 ft² compressor 002 9.4 m² 101.4 ft² ywca vestibule 017 16.7 m² 180.2 ft² ywca corridor 016 19.9 m² 213.7 ft² ywca bike lockers 019 152.3 m² 1639 ft² YWCA underground parking 003 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4 S04 12.4 m² 133.2 ft² stair #3 S03 stair #1 S01 stair #2 S02 2500 2700 3265 2700 2555 2700 930 WT-1 WT-1 WT-1 WT-1 YWCA garbage recycling VFRS garbage recycling 1 small parking space H/C parking space 1 ywca 2 ywca 1 vfrs 2 vfrs 7 vfrs 3 ywca 4 ywca 5 ywca 3 vfrs 4 vfrs 5 vfrs 6 vfrs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 4 3 2 1 FIN. FL. 93.24 m FIN. FL. 93.24 m FIN. FL. 93.24 m 2721 5850 5800 5850 5340 pedestrian walkway 1200 3600 12% slope @ 9.6m hydro kiosk S04B BIKE VERTICAL = 6 TOTAL BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE HORZ x 1 BIKE VERT=1 BIKE VERT=1 BIKE VERT=1 BIKE VERT=1 BIKE VERT=1 BIKE VERT=1 BIKE VERT=1 BIKE VERT=1 BIKE VERT=1 6 TOTAL 8 HE HF OVERHEAD GATE & PEDESTRIAN DOOR H5 H5 18508 12450 2550 21354 14712 3405 14 8732 6100 7722 4033 4300 (14') O/H door 3265 2700 2160 3000 2700 2300 2500 1500 storage zone ENTRANCE WALKWAY ENTRANCE WALKWAY 1180 EXIT WALKWAY 1100 small car 1195 5850 5800 5850 SECURITY FENCE OVERHEAD DOOR VFRS underground parking 004 36079 5340 6288 10576 4800 6504 2571 36079 30006 New EL. 94.43 New EL. 93.24 FIRE RATING 1.5 HOUR FRR 1.0 HOUR FRR LEGEND: DEDICATED FIRE DEPARTMENT AREA DEDICATED YWCA HOUSING AREA FLOOR AREAS - BASEMENT 740 M² TOTAL BASEMENT (MEASURED TO OUTSIDE OF STRUCTURE) SOUTH ELEVATION EXPOSED BUILDING FACE UNPROTECTED OPENING LIMITS NORTH ELEVATION 749.46 M² ALLOWABLE AREA OF UNPROTECTED OPENING FOR GROUPS A, B, C, D, AND F-3 LIMITING DISTANCE TO NEAREST PROPERTY EAST ELEVATION WEST ELEVATION PERCENTAGE OF UNPROTECTED OPENINGS ON CURRENT ELEVATIONS 642.09 M² 785.67 M² 607.78 M² > 9 M > 9 M 8.7 M 5.95 M 100% 100% 82% 40% N/A N/A 22.43% 15.15% FSR STATEMENT: PROJECT HAS AN FSR OF 2.72 INCLUDING NO ACCESSORY USES AND BASED ON SIMILAR MULTIFAMILY ONES. ROOFTOP AMENITY SPACE (EXTERIOR) BUT INCLUDES AMENITY ROOM (INTERIOR) FURTHER BREAKDOWN IS INCLUDED WITH THIS FSR COMPLIANCE DATA. DWELLING USES: DWELLING TYPES ARE SOCIAL HOUSING FOR SINGLE MOTHERS AND CHILDREN. FLOORS 3-4 ARE TRANSITIONAL HOUSING, AND FLOORS 5-6 ARE RENTAL ACCOMMODATION. DWELLING UNITS ARE MOSTLY 2 BEDROOM UNITS WITH 3-3 BEDROOM UNITS IN A TOTAL OF 31 UNITS. BALCONIES: EACH SUITE HAS ACCESS TO A BALCONY SPACE OF 1500mm X 3000mm AT A MINIMUM. NUMBER OF DWELLING UNITS: 31 DWELLING UNITS LOADING CODE REFERENCE PROPOSED 4.2.1.9 PARKING REQUIRED CODE REFERENCE PROPOSED 5.2.5 REQUIRED BICYCLES CODE REFERENCE PROPOSED 6.2.1.2 REQUIRED PROJECT DATA - PARKING, LOADING, BICYCLES MULTIPLE DWELLING 6.2.4.1 AMBULANCE STATION - SIMILAR 1.25 SPACES/ DWELLING UNIT 39 CLASS A 6 CLASS B 9 CLASS A - INTERIOR 4 CLASS B - EXTERIOR NOT REQUIRED 5 CLASS A - INTERIOR 4 CLASS B - EXTERIOR RESIDENTIAL - MULTIPLE DWELLING INDUSTRIAL - FIREHALL 5 STALLS: MINIMUM STALL SIZE 2500mm X 5500mm 7 STALLS: STALL SIZE - MINIMUM 2700mm X 5500mm 6500mm MANEUVERING AISLE SMALL CAR PARKING (LANE) N/A - PARKING SPACE COUNT BASED ON YWCA REQUIREMENTS 4.2.6 1 STALL: 5500mm X 2700mm NONE PROPOSED 5.2.1 NONE PROPOSED NOT REQUIRED RESIDENTIAL - MULTIPLE DWELLING INDUSTRIAL - FIREHALL N/A - PARKING SPACE COUNT BASED ON FIRE DEPARTMENT REQUIREMENTS N/A - LOADING SPACE COUNT BASED ON FIRE DEPARTMENT REQUIREMENTS RESIDENTIAL - H/C PARKING (LANE) 1 STALL: 5500mm X 4000mm 4.8.4 ONE REQUIRED Scale Checked Drawn Job No. [email protected] Vancouver, BC, Canada, V6B 1R8 203 - 128 West Pender Street Facsimile: Telephone: E-mail: 604. 684.3338 604. 684.3600 Revisions Sheet Revision (JDA+P), and cannot be used without the written consent files or design are and at all times remain the exclusive All rights reserved. These drawings, CAD and/ or Revit property of Johnston Davidson Architecture + Planning Inc. of JDA+P. These drawings are not valid for construction without the seal of the Architects. Job Title Sheet Title Client FIREHALL BASEMENT LEVEL 1209 Firehall No.5 + Housing Vancouver Fire Rescue Services + YWCA EC/CP KJ $3090 East 54th Avenue + 7001 Kerr Street 1:100 1 ISSUED FOR DP - 95% REVIEW 14-JUL-31 2 ISSUED FOR DP - 99% REVIEW 15-FEB-12 3 ISSUED FOR DP, REZONING APPLICATION 15-FEB-17 scale - 1 : 100 basement floor plan 1 3 N
Transcript
Page 1: PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4

UP

UP

UP

UP

X XX X

XX XX

A

B

FE

G

1 2 3 4 5

HA

C

7

HD

1

A3.10

1

A3.10

1

A3.9

1

A3.9

WT-

1D

WT-5

WT-

1C

S03

A

011A

012

013

007

008

009

011B

006

S01A

016

015

017

002

S04A

001

WT-

1

WT-5

WT-5

WT-1C

14.2 m²153.1 ft²

ywca mainstorage

018

44.3 m²477.2 ft²

ywca bike room 1015

9.8 m²105.8 ft²

outdoor storage013

13.2 m²142.2 ft²

maintenancestorage

012

11.7 m²126 ft²

corridor014

16.9 m²181.8 ft²

corridor011

13.8 m²148.6 ft²

mechanical room006

6.6 m²70.6 ft²

comm room007

16.6 m²178.5 ft²

electrical008

7.9 m²84.7 ft²

i.t.009

22.5 m²242.6 ft²

genset001

5.5 m²59.7 ft²

compressor002

9.4 m²101.4 ft²

ywca vestibule017

16.7 m²180.2 ft²

ywca corridor01619.9 m²

213.7 ft²

ywca bike lockers019

152.3 m²1639 ft²

YWCAunderground

parking003

1.4 m²15.2 ft²

bike area010

2.1 m²22.8 ft²

bike area010

5.6 m²60 ft²

ywca bike room 2020

1200

2321

stair #4S04

12.4 m²133.2 ft²

stair #3S03

stair #1S01

stair #2S02

2500

2700

3265

2700

2555

2700

930

WT-

1

WT-

1

WT-1

WT-

1

YWCAgarbagerecycling

VFRSgarbagerecycling

1 smallparkingspace

H/Cparkingspace

1 ywca

2 ywca

1 vfrs

2 vfrs

7 vfrs

3 ywca

4 ywca

5 ywca

3 vfrs

4 vfrs 5 vfrs

6 vfrs

1

2

3

4

5 6 7 8 9 10 11 12 13 14

15

16

17

18

19

202122232425

4

3

2

1

FIN. FL.93.24 m

FIN. FL.93.24 m

FIN. FL.93.24 m

2721 5850 5800 5850 5340

pede

stria

n w

alkw

ay

12003600

12%

slo

pe @

9.6

m

hydrokiosk

S04B

BIKE VERTICAL = 6 TOTAL

BIKE HORZ x 1

BIKE HORZ x 1

BIKE HORZ x 1

BIKE HORZ x 1

BIKE HORZ x 1

BIKE HORZ x 1

BIKE HORZ x 1

BIKE HORZ x 1

BIKE HORZ x 1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIK

E H

OR

Z x

1

BIKE

VER

T=1

BIKE

VER

T=1

BIKE

VER

T=1

BIKE

VER

T=1

BIKE

VER

T=1

BIKEVERT=1

BIKEVERT=1

BIKEVERT=1

BIKEVERT=1

6TOTAL

8

HE

HF

OVERHEAD GATE &PEDESTRIAN DOOR H5

H5

18508 12450 2550

2135414712

3405

1487

3261

0077

2240

33

4300 (14') O/H door32

6527

0021

6030

0027

0023

0025

0015

00

storage zone

ENTRANCE WALKWAY

ENTRANCE WALKWAY

1180

EXIT WALKWAY

1100

small car

1195

5850 5800 5850

SECURITYFENCE

OVERHEADDOOR

VFRSunderground

parking004

36079

5340628810576480065042571

36079

3000

6

New EL. 94.43

New EL. 93.24 FIRE RATING

1.5 HOUR FRR

1.0 HOUR FRR

LEGEND:

DEDICATED FIREDEPARTMENT AREA

DEDICATED YWCAHOUSING AREA

FLOOR AREAS - BASEMENT

740 M² TOTAL BASEMENT (MEASURED TOOUTSIDE OF STRUCTURE)

SOUTHELEVATION

EXPOSED BUILDING FACE

UNPROTECTED OPENING LIMITSNORTHELEVATION

749.46 M²

ALLOWABLE AREA OF UNPROTECTED OPENINGFOR GROUPS A, B, C, D, AND F-3

LIMITING DISTANCE TO NEAREST PROPERTY

EASTELEVATION

WESTELEVATION

PERCENTAGE OF UNPROTECTED OPENINGS ONCURRENT ELEVATIONS

642.09 M² 785.67 M² 607.78 M²

> 9 M > 9 M 8.7 M 5.95 M

100% 100% 82% 40%

N/A N/A 22.43% 15.15%

FSR STATEMENT:PROJECT HAS AN FSR OF 2.72 INCLUDING NO ACCESSORYUSES AND BASED ON SIMILAR MULTIFAMILY ONES.ROOFTOP AMENITY SPACE (EXTERIOR) BUT INCLUDESAMENITY ROOM (INTERIOR) FURTHER BREAKDOWN ISINCLUDED WITH THIS FSR COMPLIANCE DATA.

DWELLING USES:DWELLING TYPES ARE SOCIAL HOUSING FOR SINGLEMOTHERS AND CHILDREN. FLOORS 3-4 ARE TRANSITIONALHOUSING, AND FLOORS 5-6 ARE RENTAL ACCOMMODATION.DWELLING UNITS ARE MOSTLY 2 BEDROOM UNITS WITH 3-3BEDROOM UNITS IN A TOTAL OF 31 UNITS.

BALCONIES:EACH SUITE HAS ACCESS TO A BALCONY SPACE OF 1500mmX 3000mm AT A MINIMUM.

NUMBER OF DWELLING UNITS: 31 DWELLING UNITS

LOADING

CODEREFERENCE

PROPOSED

4.2.1.9

PARKINGREQUIRED

CODEREFERENCE

PROPOSED

5.2.5

REQUIRED

BICYCLESCODEREFERENCE

PROPOSED

6.2.1.2

REQUIRED

PROJECT DATA - PARKING, LOADING, BICYCLES

MULTIPLEDWELLING

6.2.4.1 AMBULANCESTATION -SIMILAR

1.25 SPACES/DWELLINGUNIT

39 CLASS A6 CLASS B

9 CLASS A - INTERIOR4 CLASS B - EXTERIOR

NOT REQUIRED 5 CLASS A - INTERIOR4 CLASS B - EXTERIOR

RESIDENTIAL -MULTIPLEDWELLING

INDUSTRIAL -FIREHALL

5 STALLS:MINIMUM STALL SIZE2500mm X 5500mm

7 STALLS:STALL SIZE - MINIMUM 2700mm X5500mm6500mm MANEUVERING AISLE

SMALL CARPARKING(LANE)

N/A - PARKING SPACECOUNT BASED ON YWCAREQUIREMENTS

4.2.6

1 STALL:5500mm X 2700mm

NONEPROPOSED

5.2.1 NONEPROPOSED

NOT REQUIREDRESIDENTIAL -MULTIPLEDWELLINGINDUSTRIAL -FIREHALL

N/A - PARKING SPACE COUNTBASED ON FIRE DEPARTMENTREQUIREMENTS

N/A - LOADING SPACE COUNTBASED ON FIRE DEPARTMENTREQUIREMENTS

RESIDENTIAL -H/C PARKING(LANE)

1 STALL:5500mm X 4000mm4.8.4 ONE REQUIRED

ScaleCheckedDrawn

Job No.

[email protected]

Vancouver, BC, Canada, V6B 1R8

203 - 128 West Pender Street

Facsimile:

Telephone:

E-mail:

604. 684.3338

604. 684.3600

Revisions

Sheet

Revision

(JDA+P), and cannot be used without the written consent

files or design are and at all times remain the exclusiveAll rights reserved. These drawings, CAD and/ or Revit

property of Johnston Davidson Architecture + Planning Inc.

of JDA+P. These drawings are not valid for constructionwithout the seal of the Architects.

Job Title

Sheet Title

Client

FIREHALLBASEMENT LEVEL

1209

Firehall No.5 +Housing

Vancouver Fire RescueServices + YWCA

EC/CPKJ

3090 East 54th Avenue+ 7001 Kerr Street

1:100

1ISSUED FOR DP - 95%REVIEW 14-JUL-31

2 ISSUED FOR DP - 99%REVIEW

15-FEB-12

3ISSUED FOR DP, REZONINGAPPLICATION 15-FEB-17

scale - 1 : 100

basement floor plan1

3

N

Page 2: PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4

UP

UP

UP

UP

DN

A

B

EG

1

1

2

2 3 4 5

HA

C

6 7

I

10

JD

1

A3.10

1

A3.10

1

A3.9

1

A3.9

4990

119A

117

116

118

115

114B

114A

102

106

105

104

108

121

122

124B124A

103

100

S01B

109

119F

S03B

112

128

126 125

10.5 m²112.5 ft²

vestibule100

16.7 m²179.8 ft²

entry101

54.1 m²582.7 ft²

community room103

4.8 m²51.7 ft²

h/c102

9.6 m²103 ft²

storage104

15.1 m²162.3 ft²

captain's office108

43.1 m²463.5 ft²

day room109

48.1 m²517.8 ft²

kitchen110

3.5 m²38 ft²

jan rm105

2.2 m²24.1 ft²

w/r106

29.5 m²317.4 ft²

mask repair116

7.1 m²76.4 ft²

office115

28.7 m²308.9 ft²

filling andwashdown

114

9.7 m²104.8 ft²

workshop117

47.1 m²506.5 ft²

gear storage122

6.5 m²70.4 ft²

decon rm121

19.8 m²213 ft²

hose tower124

8.9 m²95.4 ft²

stores area123

29 m²312.1 ft²

corridor112

9 m²97.3 ft²

corridor113

10 m²107.8 ft²

study + f/a107

328.1 m²3532.2 ft²

apparatus bays119

101

12.2 m²131.7 ft²

lobby126

7.1 m²76.3 ft²

pm office128

4.5 m²48 ft²

vest.125

stair #4S04

stair #3S03

12.8 m²137.5 ft²

stair #1S01

total=44 units

6 units

6 units

9 un

its

12 u

nits

12 units

FIN. FL.97.00 m

FIN. FL.96.80 m

DN

CONCRETE WALLAROUND KIOSK ATNORTH AND EASTSIDES

1500MM METALSLAT SCREEN

FUELFILLING

LOCATION

trenc

h dr

ain

trenc

h dr

ain

trenc

h dr

ain

HYDRO KIOSK

fc

bc

24 cylindermobile rack

24 cylindermobile rack

24 cylindermobile rack

24 cylindermobile rack

24 cylindermobile rack

24 cy

linde

rmo

bile r

ack bi

ns

rip & run

bins

bins

bins

jan

st

recy

ling

5.7 m²61.2 ft²

utility room118

8 9

3.3 m²35.2 ft²

pole room127

1500MM METALSLAT SCREEN

ENCLOSURE ATFUEL TANK

UP

H5

915

LIGHTBOLLARD

119B

3549

0

FIREHYDRANT

FENCE ATPROPERTY

LINE ONCONCRETERETAINING

WALL

110

ACCESS TOPARKING

RAMP DOWNAT 12%

LANE PARKING

YWCAGARBAGE

RECYCLINGH/C PARKING

SPACE

VFRSGARBAGE

RECYCLING

1 SMALLPARKING

STALL

2378

7055

8043

1248

755

27

3549

0

38607

38607

119C

LEGEND:

DEDICATED FIREDEPARTMENT AREA

DEDICATED YWCAHOUSING AREA

FLOOR AREAS - MAIN FLOOR

959 sm total main floor (measured to outsideof structure)

SOUTHELEVATION

EXPOSED BUILDING FACE

UNPROTECTED OPENING LIMITSNORTHELEVATION

749.46 M²

ALLOWABLE AREA OF UNPROTECTED OPENINGFOR GROUPS A, B, C, D, AND F-3

LIMITING DISTANCE TO NEAREST PROPERTY

EASTELEVATION

WESTELEVATION

PERCENTAGE OF UNPROTECTED OPENINGS ONCURRENT ELEVATIONS

642.09 M² 785.67 M² 607.78 M²

> 9 M > 9 M 8.7 M 5.95 M

100% 100% 82% 40%

N/A N/A 22.43% 15.15%

FSR STATEMENT:PROJECT HAS AN FSR OF 2.72 INCLUDING NO ACCESSORYUSES AND BASED ON SIMILAR MULTIFAMILY ONES.ROOFTOP AMENITY SPACE (EXTERIOR) BUT INCLUDESAMENITY ROOM (INTERIOR) FURTHER BREAKDOWN ISINCLUDED WITH THIS FSR COMPLIANCE DATA.

NUMBER OF DWELLING UNITS: 31 DWELLING UNITS

ScaleCheckedDrawn

Job No.

[email protected]

Vancouver, BC, Canada, V6B 1R8

203 - 128 West Pender Street

Facsimile:

Telephone:

E-mail:

604. 684.3338

604. 684.3600

Revisions

Sheet

Revision

(JDA+P), and cannot be used without the written consent

files or design are and at all times remain the exclusiveAll rights reserved. These drawings, CAD and/ or Revit

property of Johnston Davidson Architecture + Planning Inc.

of JDA+P. These drawings are not valid for constructionwithout the seal of the Architects.

Job Title

Sheet Title

Client

FIREHALLMAIN FLOOR PLAN

1209

Firehall No.5 +Housing

Vancouver Fire RescueServices + YWCA

ECKJ

3090 East 54th Avenue+ 7001 Kerr Street

1:100

1ISSUED FOR DP - 95%REVIEW 14-JUL-31

2 ISSUED FOR DP - 99%REVIEW

15-FEB-12

3ISSUED FOR DP, REZONINGAPPLICATION 15-FEB-17

scale - 1 : 100

main floor plan1

3

N

Page 3: PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4

DN

UP

UP

UPUP

A

B

FE

G

1 2 5

HA

C

10

D

1

A3.10

1

A3.10

1

A3.9

1

A3.9

210

211

213

214

215

124C

200A

200B

S01C

WT-08

WT-

9

WT-6W

T-1D

WT-

1CW

T-1C

WT-2A

WT-

2AW

T-2A

WT-2B

WT-5

54.5 m²586.6 ft²

fitness room200

12 m²129.1 ft²

officer's dorm 1210

12 m²129.1 ft²

officer's dorm 2211

7.1 m²76.7 ft²

w/r #1214

7.1 m²76.7 ft²

w/r #2215

3.7 m²39.9 ft²

pole rm213

7.1 m²76.7 ft²

w/r #4204

40 m²430.4 ft²

4 person dorm201

8.9 m²96 ft²

corridor212

42.8 m²460.6 ft²

corridor209

41.1 m²441.9 ft²

4 person dorm208

13 m²139.7 ft²

corridor203

8.1 m²87.4 ft²

mechanical room200A

3.4 m²36.6 ft²

utility202

47.5 m²510.8 ft²

mezzanine216

stair #1S01

FIN. FL.100.90 m

328.1 m²3532.2 ft²

apparatus bays119

open to below

DN

greenroof

intensivegreen roof

206

205

204

WT-

7

7.1 m²76.7 ft²

w/r #3205

1.4 m²15.5 ft²

jan rm206

1.9 m²20.5 ft²

ph rm207

dryer wash

8 9

HE

HF

H5

H5

36997

2134

5207

209

intensive green roof

planter

38607

3549

0

3012 21898 5784 6303

recycling

SOUTHELEVATION

EXPOSED BUILDING FACE

UNPROTECTED OPENING LIMITSNORTHELEVATION

749.46 M²

ALLOWABLE AREA OF UNPROTECTED OPENINGFOR GROUPS A, B, C, D, AND F-3

LIMITING DISTANCE TO NEAREST PROPERTY

EASTELEVATION

WESTELEVATION

PERCENTAGE OF UNPROTECTED OPENINGS ONCURRENT ELEVATIONS

642.09 M² 785.67 M² 607.78 M²

> 9 M > 9 M 8.7 M 5.95 M

100% 100% 82% 40%

N/A N/A 22.43% 15.15%

LEGEND:

DEDICATED FIREDEPARTMENT AREA

DEDICATED YWCAHOUSING AREA

FLOOR AREAS

485.71 sm upper floor (measured to outside ofstructure)

FSR STATEMENT:PROJECT HAS AN FSR OF 2.72 INCLUDING NO ACCESSORYUSES AND BASED ON SIMILAR MULTIFAMILY ONES.ROOFTOP AMENITY SPACE (EXTERIOR) BUT INCLUDESAMENITY ROOM (INTERIOR) FURTHER BREAKDOWN ISINCLUDED WITH THIS FSR COMPLIANCE DATA.

NUMBER OF DWELLING UNITS: 31 DWELLING UNITS

ScaleCheckedDrawn

Job No.

[email protected]

Vancouver, BC, Canada, V6B 1R8

203 - 128 West Pender Street

Facsimile:

Telephone:

E-mail:

604. 684.3338

604. 684.3600

Revisions

Sheet

Revision

(JDA+P), and cannot be used without the written consent

files or design are and at all times remain the exclusiveAll rights reserved. These drawings, CAD and/ or Revit

property of Johnston Davidson Architecture + Planning Inc.

of JDA+P. These drawings are not valid for constructionwithout the seal of the Architects.

Job Title

Sheet Title

Client

FIREHALL2ND FLOOR PLAN

1209

Firehall No.5 +Housing

Vancouver Fire RescueServices + YWCA

KJKJ

3090 East 54th Avenue+ 7001 Kerr Street

1:100

1ISSUED FOR DP - 95%REVIEW 14-JUL-31

2 ISSUED FOR DP - 99%REVIEW

15-FEB-12

3ISSUED FOR DP, REZONINGAPPLICATION 15-FEB-17

scale - 1 : 100

second floor plan1

3

N

Page 4: PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4

UP

UP

UPUP

B

1 5

HA

7

7

D

1

A3.10

1

A3.10

1

A3.9

1

A3.9

1500

06-F

06-G

06-J

06-I

07-A

08-A

06-A

05-A

04-A

310B

02-A

307A

01-A

AR-A

311

300

07-B07-K

07-H

07-D

05-I

05-F

05-G

05-J

04-G

04-F

04-I

04-J

02-H

02-G

02-D

02-B

307B

AR-D

AR-B

01-F

01-E

01-H

01-I

08-D

08-C

08-H

08-J

303

06-E

06-D

06-H 04-H

04-E

04-D

07-I

07-E

05-D

05-E

05-H

01-G

02-I

02-F

08-E

08-I

08-B

08-G

06-B

04-B

02-C

01-J

05-B

living08-03

5.1m x 3.6m

2nd bed08-02

4.0m x 2.6m

main bed08-01

4.0m x 2.7m

w/r08-07

1.5m x 2.4m

storage08-06

1.6m x 2.3m

pantry08-05

entry08-08

kitchen08-04

2.5m x 3.1m

living06-02

3.6m x 5.0m

2nd bed06-03

2.6m x 4.0m

main bed06-04

2.8m x 4.3m

w/r06-05

1.5m x 2.6mstorage06-06

2.0m x 1.6mw/d06-07

w/d04-07

living01-02

5.0m x 3.5m

2nd bed01-03

4.0m x 2.6m

main bed01-04

4.6m x 2.6m

w/r01-05

2.6m x 1.5m

storage01-06

w/d01-07

main bed07-04

3.1m x 3.5m

2nd bed07-05

2.5m x 3.8m

storage07-06

1.7m x 2.2mw/d07-08

pantry07-09

kitchen05-01

2.9m x 2.6m

07-J

07-G

living02-02

6.1m x 3.0m

main bed02-03

4.0m x 2.7m

2nd bed02-04

4.0m x 2.7m

storage02-06

1.5m x 2.5m pant

ry02

-05

w/r02-07

2.5m x 1.5m

kitchen02-01

1.8m x 4.8m

entry02-08

laundry307A

4.1m x 3.1m

comm. closet307B

janitor310A

310A

Not Enclosed

stair #4S04

stair #3S03

officeAR-02

3.3m x 3.5m

hc w/r310B

1.8m x 2.5m

storageAR-03

2.5m x 1.9m

great roomAR-01

9.1m x 4.6m

ywca lt310C

310C

kitchenAR-04

4.1m x 2.3m

elevator lobby311

3.3m x 2.9m

15.1 m²

corridor309

45.6 m²

corridor310

kitchen01-01

2.6m x 2.9m

entry01-08

01-B

01-D

07-F

patio01-10

1.5 x 6.0

balcony04-10

3.3m x 1.5m

hose tower124

kitchen06-01

2.9m x 2.6m

main bed04-04

2.8m x 4.3m

2nd bed04-03

2.6m x 4.0m

living04-02

2.6m x 4.3m

storage04-06

2.0m x 1.6m

w/r04-05

1.5m x 2.6m kitchen04-01

2.9m x 2.6m

amenity roomunit 301

unit302

unit303

unit304

unit305

unit306

unit307

unit308

9

HB

HB

HD

HE

HF

HG

HG

H3 H4 H6

HH

HI

HI

H7H1 H2

HC

HC

H5

H5

amenitypatio

roofpatio

roofpatio

1500

storage05-06

2.0m x 1.6m

2nd bed05-03

2.6m x 4.0m

main bed05-04

2.8m x 4.3m

living05-02

3.6m x 5.0m

w/r05-05

1.5m x 2.6m

w/d05-07

w/r07-01

2.4m x 1.5m

kitchen07-02

2.4m x 2.6m

living07-03

3.8m x 5.6m

balcony06-10

3.3m x 1.5m

balcony02-09

3.0m x 1.5m

balcony08-09

3.0m x 1.5m

dividersbetweenpatios

patio guard atamenity room tobe 2100mm high

movableplanters

roof roof

1500mm highguards @ thislevel

37875

2521

729

65

522

5582

9897

1500

7716

1591

FLOOR AREAS:

744.83 smtypical floor plate area (includingstairwells)

5 dwelling units on 3rd floor, 6 dwelling units on floors 4 through 6

SOUTHELEVATION

EXPOSED BUILDING FACE

UNPROTECTED OPENING LIMITSNORTHELEVATION

749.46 M²

ALLOWABLE AREA OF UNPROTECTED OPENINGFOR GROUPS A, B, C, D, AND F-3

LIMITING DISTANCE TO NEAREST PROPERTY

EASTELEVATION

WESTELEVATION

PERCENTAGE OF UNPROTECTED OPENINGS ONCURRENT ELEVATIONS

642.09 M² 785.67 M² 607.78 M²

> 9 M > 9 M 8.7 M 5.95 M

100% 100% 82% 40%

N/A N/A 22.43% 15.15%

FSR STATEMENT:PROJECT HAS AN FSR OF 2.72 INCLUDING NO ACCESSORYUSES AND BASED ON SIMILAR MULTIFAMILY ONES.ROOFTOP AMENITY SPACE (EXTERIOR) BUT INCLUDESAMENITY ROOM (INTERIOR) FURTHER BREAKDOWN ISINCLUDED WITH THIS FSR COMPLIANCE DATA.

NUMBER OF DWELLING UNITS: 31 DWELLING UNITS

ScaleCheckedDrawn

Job No.

[email protected]

Vancouver, BC, Canada, V6B 1R8

203 - 128 West Pender Street

Facsimile:

Telephone:

E-mail:

604. 684.3338

604. 684.3600

Revisions

Sheet

Revision

(JDA+P), and cannot be used without the written consent

files or design are and at all times remain the exclusiveAll rights reserved. These drawings, CAD and/ or Revit

property of Johnston Davidson Architecture + Planning Inc.

of JDA+P. These drawings are not valid for constructionwithout the seal of the Architects.

Job Title

Sheet Title

Client

HOUSING3RD FLOOR PLAN

1209

Firehall No.5 +Housing

Vancouver Fire RescueServices + YWCA

JBKJ

3090 East 54th Avenue+ 7001 Kerr Street

1:100

1ISSUED FOR DP - 95%REVIEW 14-JUL-31

2 ISSUED FOR DP - 99%REVIEW

15-FEB-12

3ISSUED FOR DP, REZONINGAPPLICATION 15-FEB-17

scale - 1 : 100

3rd floor plan1

3

N

Page 5: PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4

UP

UP

B

1 5

HA

7

7

D

1

A3.10

1

A3.10

1

A3.9

1

A3.9

18-A

18-D

18-C

18-H

18-J

18-E

18-I

18-B

18-G

403

16-A

16-I

16-G

16-F

16-J

16-D

16-H

16-B

16-E

14-A

14-I

14-G

14-F

14-J

14-D

14-H

14-B

14-E

15-A

15-I

15-G

15-F

15-J

15-D

15-H

15-B

15-E

13-D

13-G

13-H

13-A

13-E

13-C

13-F

13-B

11-A

11-G

11-F

11-I

11-J

11-B

living16-02

3.6m x 5.0m

2nd bed16-03

2.6m x 4.0m

main bed16-04

2.8m x 4.3

main bed14-04

2.8m x 4.3

2nd bed14-03

2.6m x 4.0m

living14-02

3.6m x 5.0m

pant

ry16

-07 storage

16-062.0m x 1.6m

w/r16-05

1.5m x 2.6m

w/r14-05

1.5m x 2.6m storage14-06

2.0m x 1.6m pant

ry14

-07

living15-02

3.6m x 5.0m

2nd bed15-03

2.6m x 4.0m

main bed15-04

2.8m x 4.3

w/r15-05

1.5m x 2.6m

storage15-06

2.0m x 1.6mpant

ry15

-07

corridor409

corridor410

living18-03

5.1m x 3.6m

kitchen18-04

2.5m x 3.1m

2nd bed18-02

2.6m X 4.3m

storage18-06

1.6m x 2.3m

pantry18-05

w/r18-07

1.5m x 2.4m

entry18-08

main bed18-01

4.0m x 2.7mkitchen

16-012.9m x 2.6m

2nd bed13-01

2.8m x 4.6m

main bed13-03

2.6m x 4.4m

storage13-04

1.5m x 2.5m

pantry13-06

w/r13-07

3.0mx 2.4m

living13-02

4.2m x 5.2m

kitchen13-05

4.4m x 2.3m

entry13-08

w/r11-05

2.6m x 1.5m

stair #4S04

stair #3S03

kitchen14-01

2.9m x 2.6m

kitchen15-08

2.9m x 2.6m

living17-03

3.8m x 5.5m

2nd bed17-05

2.5m x 3.8m

storage17-06

1.7m x 2.2m

w/r17-01

2.4m x 1.5mw/d17-08

pantry17-09

kitchen17-02

2.4m x 2.6m

entry17-07

living11-02

4.9m x 3.6m

2nd bed11-03

4.0m x 2.6m

main bed11-04

2.7m x 4.4mstorage

11-061.6m x 2.0m

pantry11-07

kitchen11-01

2.6m x 2.9m

entry11-08

17-A

17-K17-B

17-J

17-G

17-E

17-D

17-H

17-I

elec. rm.410A

living12-02

6.1m x 3.0m

kitchen12-01

1.8m x 4.4m

storage12-09

2.8m x 1.3m

wc12-07

1.6m x 1.4m

w/r12-06

2.4m x 1.5m

main bed12-05

4.8m x 2.4m

2nd bed12-04

4.0m x 2.7m

3rd bed12-03

4.0m x 2.7m

entry12-10

pant

ry12

-08

402

401

400

12-I

12-K

12-L

12-D

12-C

12-A

12-M

12-J

12-H

12-F

12-B

12-E

elevator lobby400

2.9m x 3.3m

13-I

11-D

11-E

11-H

17-F

0

balcony11-10

6.9m x 1.5m

balcony14-08

3.3m x1.5m

balcony16-08

3.3m x 1.5m

balcony13-09

3.0m x 1.5m

9

HB

HB

HD

HE

HF

HG

H3 H4 H6

HH

HI

H7H1 H2

HC

H5

H5

unit401

unit402

unit403

unit404

unit405

unit306

unit407

unit408

37875

2709

8

37875

10.9 m²

main bed17-04

3.1m x 3.5m

balcony18-09

3.0m x 1.5m

balcony12-11

3.0m x 1.5m

balcony15-09

3.0m x 1.5m

balcony17-10

3.0m x 1.5m

2491

1753

accessiblesuite

roof

FLOOR AREAS:

744.83 smtypical floor plate area (includingstairwells)

5 dwelling units on 3rd floor, 6 dwelling units on floors 4 through 6

SOUTHELEVATION

EXPOSED BUILDING FACE

UNPROTECTED OPENING LIMITSNORTHELEVATION

749.46 M²

ALLOWABLE AREA OF UNPROTECTED OPENINGFOR GROUPS A, B, C, D, AND F-3

LIMITING DISTANCE TO NEAREST PROPERTY

EASTELEVATION

WESTELEVATION

PERCENTAGE OF UNPROTECTED OPENINGS ONCURRENT ELEVATIONS

642.09 M² 785.67 M² 607.78 M²

> 9 M > 9 M 8.7 M 5.95 M

100% 100% 82% 40%

N/A N/A 22.43% 15.15%

FSR STATEMENT:PROJECT HAS AN FSR OF 2.72 INCLUDING NO ACCESSORYUSES AND BASED ON SIMILAR MULTIFAMILY ONES.ROOFTOP AMENITY SPACE (EXTERIOR) BUT INCLUDESAMENITY ROOM (INTERIOR) FURTHER BREAKDOWN ISINCLUDED WITH THIS FSR COMPLIANCE DATA.

NUMBER OF DWELLING UNITS: 31 DWELLING UNITS

ScaleCheckedDrawn

Job No.

[email protected]

Vancouver, BC, Canada, V6B 1R8

203 - 128 West Pender Street

Facsimile:

Telephone:

E-mail:

604. 684.3338

604. 684.3600

Revisions

Sheet

Revision

(JDA+P), and cannot be used without the written consent

files or design are and at all times remain the exclusiveAll rights reserved. These drawings, CAD and/ or Revit

property of Johnston Davidson Architecture + Planning Inc.

of JDA+P. These drawings are not valid for constructionwithout the seal of the Architects.

Job Title

Sheet Title

Client

HOUSING4TH FLOOR PLAN

1209

Firehall No.5 +Housing

Vancouver Fire RescueServices + YWCA

JBKJ

3090 East 54th Avenue+ 7001 Kerr Street

1:100

1ISSUED FOR DP - 95%REVIEW 14-JUL-31

2 ISSUED FOR DP - 99%REVIEW

15-FEB-12

3ISSUED FOR DP, REZONINGAPPLICATION 15-FEB-17

scale - 1 : 100

4th floor plan1

3

(INCLUDES ACCESSIBLE DWELLING UNIT - 401)N

Page 6: PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4

UP

UP

B

1

HA

7

7

D

1

A3.10

1

A3.10

1

A3.9

1

A3.9

corridor509

corridor510

living26-02

3.6m x 5.0m

2nd bed26-03

2.6m x 4.0m

main bed26-04

2.8m x 4.3

w/r26-05

1.5m x 2.6mstorage26-06

2.0m x 1.6mpant

ry26

-07

living24-02

3.6m x 5.0m

2nd bed24-03

2.6m x 4.0m

main bed24-04

2.8m x 4.3

w/r24-05

1.5m x 2.6m storage24-06

2.0m x 1.6m pant

ry24

-07

living25-02

3.6m x 5.0m

2nd bed25-03

2.6m x 4.0m

main bed25-04

2.8m x 4.3

w/r25-05

1.5m x 2.6m

storage25-06

2.0m x 1.6m

pant

ry25

-07

stair #4S04

stair #3S03

living28-03

5.1m x 3.6m

2nd bed28-02

2.6m X 4.3m

main bed28-01

4.0m x 2.7m

w/r28-07

1.5m x 2.4m

storage28-06

1.6m x 2.3m

pantry28-05

entry28-08

kitchen28-04

2.5m x 3.1m

kitchen26-01

2.9m x 2.6m

kitchen24-01

2.9m x 2.6m

kitchen25-01

2.9m x 2.6m

2nd bed23-01

2.8m x 4.6m

main bed23-03

2.6m x 4.4m

storage23-04

1.5m x 2.5m

pant

ry23

-07

w/r23-06

3.0mx 2.4m

living23-02

4.2m x 5.2m

kitchen23-05

4.4m x 2.3m

entry23-08

living27-03

3.8m x 5.5m

main bed27-04

3.1m x 3.5m

2nd bed27-05

2.5m x 3.8m

storage27-06

1.7m x 2.2m

w/r27-01

2.4m x 1.5mw/d27-08

pantry27-09

kitchen27-02

2.4m x 2.6m

entry27-07

elevator lobby500

2.9m x 3.3m

living22-02

6.1m x 3.0m

kitchen22-01

1.8m x 4.4m

storage22-09

2.8m x 1.3m

wc22-08

1.6m x 1.4m

w/r22-06

2.4m x 1.5m

main bed22-05

4.8m x 2.4m

2nd bed22-04

4.0m x 2.7m

3rd bed22-03

4.0m x 2.7m

entry22-10

pant

ry22

-07

janitor510A

501

500

502

503

28-D

28-C

28-H

28-J

28-B

28-E

28-I

28-G

28-A

26-A

26-I

26-G

26-F

26-J

26-D

26-H

26-B

26-E

24-A

24-I

24-G

24-F

24-J

24-D

24-H

24-B

24-E

25-A

25-I

25-G

25-F

25-J

25-D

25-H

25-B

25-E

23-H

23-A

23-E

23-C

23-F

23-B

23-D

23-G

27-A

27-B27-K

27-H

27-D

27-E

27-I

27-J

27-G

22-I

22-K

22-D

22-C

22-M

22-J

22-H

22-F

22-B

22-E

22-A

22-L

23-I

21-A

21-G

21-F

21-I

21-J

21-B 21-D

21-E

21-H

living21-02

4.9m x 3.6m

2nd bed21-03

4.0m x 2.6m

main bed21-04

2.7m x 4.4m

w/r21-05

2.6m x 1.5m

storage21-06

1.6m x 2.0m

pantry21-07

kitchen21-01

2.6m x 2.9m

entry21-08

balcony21-10

6.9m x 1.5m

balcony24-08

3.3m x1.5m

balcony26-08

3.3m x 1.5m

9

HB

HD

HE

HF

HG

H3 H4 H6

HH

HI

H7H1 H2

HC

H5

H5

unit501

unit502

unit503

unit504

unit505

unit506

unit507

unit508

1762 8089 18232 8481 1311

37875

5991

5987

9306

2128

458

14

2818

310

168

1160

764

07

2269 7582 14537 6306 7181

37875

balcony22-11

balcony25-08

3.0m x 1.5m

balcony27-10

3.0m x 1.5m

balcony23-09

3.0m x 1.5m

balcony28-09

3.0m x 1.5m

accessiblesuite

FLOOR AREAS:

744.83 smtypical floor plate area (includingstairwells)

5 dwelling units on 3rd floor, 6 dwelling units on floors 4 through 6

SOUTHELEVATION

EXPOSED BUILDING FACE

UNPROTECTED OPENING LIMITSNORTHELEVATION

749.46 M²

ALLOWABLE AREA OF UNPROTECTED OPENINGFOR GROUPS A, B, C, D, AND F-3

LIMITING DISTANCE TO NEAREST PROPERTY

EASTELEVATION

WESTELEVATION

PERCENTAGE OF UNPROTECTED OPENINGS ONCURRENT ELEVATIONS

642.09 M² 785.67 M² 607.78 M²

> 9 M > 9 M 8.7 M 5.95 M

100% 100% 82% 40%

N/A N/A 22.43% 15.15%

FSR STATEMENT:PROJECT HAS AN FSR OF 2.72 INCLUDING NO ACCESSORYUSES AND BASED ON SIMILAR MULTIFAMILY ONES.ROOFTOP AMENITY SPACE (EXTERIOR) BUT INCLUDESAMENITY ROOM (INTERIOR) FURTHER BREAKDOWN ISINCLUDED WITH THIS FSR COMPLIANCE DATA.

NUMBER OF DWELLING UNITS: 31 DWELLING UNITS

ScaleCheckedDrawn

Job No.

[email protected]

Vancouver, BC, Canada, V6B 1R8

203 - 128 West Pender Street

Facsimile:

Telephone:

E-mail:

604. 684.3338

604. 684.3600

Revisions

Sheet

Revision

(JDA+P), and cannot be used without the written consent

files or design are and at all times remain the exclusiveAll rights reserved. These drawings, CAD and/ or Revit

property of Johnston Davidson Architecture + Planning Inc.

of JDA+P. These drawings are not valid for constructionwithout the seal of the Architects.

Job Title

Sheet Title

Client

HOUSING5TH FLOOR PLAN

1209

Firehall No.5 +Housing

Vancouver Fire RescueServices + YWCA

JBKJ

3090 East 54th Avenue+ 7001 Kerr Street

1:100

1ISSUED FOR DP - 95%REVIEW 14-JUL-31

2 ISSUED FOR DP - 99%REVIEW

15-FEB-12

3ISSUED FOR DP, REZONINGAPPLICATION 15-FEB-17

scale - 1 : 100

5th floor plan1

3

(INCLUDES ACCESSIBLE DWELLING UNIT - 501)

N

Page 7: PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4

UP

B

1

HA

7

D

1

A3.10

1

A3.10

1

A3.9

1

A3.9

corridor609

corridor610

living36-02

3.6m x 5.0m

2nd bed36-03

2.6m x 4.0m

main bed36-04

2.8m x 4.3

main bed34-04

2.8m x 4.3

2nd bed34-03

2.6m x 4.0m17.7 m²

living34-02

3.6m x 5.0m

living35-02

3.6m x 5.0m

2nd bed35-03

2.6m x 4.0m

main bed35-04

2.8m x 4.3

living38-03

5.1m x 3.6m

2nd bed38-02

2.6m X 4.3m

main bed38-01

4.0m x 2.7m

kitchen38-04

2.5m x 3.1m

pantry38-05

storage38-06

1.6m x 2.3m

w/r38-07

1.5m x 2.4m

entry38-08 storage

36-062.0m x 1.6mpa

ntry

36-0

7 w/r36-05

1.5m x 2.6m

w/r34-05

1.5m x 2.6m

storage34-06

2.0m x 1.6m pant

ry34

-07

storage35-06

2.0m x 1.6m

w/r35-05

1.5m x 2.6mpant

ry35

-07

stair #4S04

stair #3S03

kitchen36-01

2.9m x 2.6m

kitchen34-01

2.9m x 2.6m

kitchen35-01

2.9m x 2.6m

2nd bed33-01

2.8m x 4.6m

main bed33-03

2.6m x 4.4m

storage33-04

1.5m x 2.5m

pant

ry33

-07

w/r33-06

3.0mx 2.4m

living33-02

4.2m x 5.2m

kitchen33-05

4.4m x 2.3m

entry33-08

elevator lobby600

2.9m x 3.3m

living32-02

6.1m x 3.0m

kitchen32-01

1.8m x 4.4m

storage32-09

2.8m x 1.3m

wc32-08

1.6m x 1.4m

w/r32-06

2.4m x 1.5m

main bed32-05

4.8m x 2.4m

2nd bed32-04

4.0m x 2.7m

3rd bed32-03

4.0m x 2.7m

entry32-10

pant

ry32

-07

elec. rm.610A

603

610A

601

600

living31-02

4.9m x 3.6m

2nd bed31-03

4.0m x 2.6m

main bed31-04

2.7m x 4.4m

w/r31-05

2.6m x 1.5m

storage31-06

1.6m x 2.0m

pantry31-07

kitchen31-01

2.6m x 2.9m

entry31-08

38-D

38-C

38-H

38-J

38-B

38-E

38-I

38-G

38-A

36-A

36-I

36-G

36-F

36-J

36-D

36-H

36-B

36-E

34-A

34-I

34-G

34-F

34-J

34-D

34-H

34-B

34-E

35-A

35-I

35-G

35-F

35-J

35-D

35-H

35-B

35-E

33-H

33-A

33-E

33-C

33-F

33-B

33-D

33-G

32-I

32-K

32-D

32-C

32-M

32-J

32-H

32-F

32-B

32-E

32-A

32-L

33-I

31-A

31-G

31-F

31-I

31-J

31-B 31-D

31-E

31-H

balcony31-10

3.9m x 1.5m

balcony34-08

3.3m x 1.5m

balcony36-08

3.3m x 1.5m

9

HB

HB

HD

HE

HF

HG

H3 H4 H6

HH

HI

H7H1 H2

HC

H5

unit601

unit602

unit603

unit604

unit605

unit606

unit607

unit608

3

A3.8

1084

9306

5987

5991

5814

36565

2818

3

2269 7582 14537 6306 7181

37875

2709

8

balcony32-11

3.0m x 1.5m

balcony33-09

3.0m x 1.5m

balcony35-08

3.0m x 1.5m

balcony37-10

3.0m x 1.5m

storage37-06

1.7m x 2.2m

2nd bed37-05

2.5m x 3.8m

main bed37-04

3.1m x 3.5m

living37-03

3.8m x 5.5m

kitchen37-02

2.4m x 2.6m

w/r37-01

2.4m x 1.5mentry37-07

w/d37-08

pantry37-09 accessible

suite

FLOOR AREAS:

744.83 smtypical floor plate area (includingstairwells)

5 dwelling units on 3rd floor, 6 dwelling units on floors 4 through 6

SOUTHELEVATION

EXPOSED BUILDING FACE

UNPROTECTED OPENING LIMITSNORTHELEVATION

749.46 M²

ALLOWABLE AREA OF UNPROTECTED OPENINGFOR GROUPS A, B, C, D, AND F-3

LIMITING DISTANCE TO NEAREST PROPERTY

EASTELEVATION

WESTELEVATION

PERCENTAGE OF UNPROTECTED OPENINGS ONCURRENT ELEVATIONS

642.09 M² 785.67 M² 607.78 M²

> 9 M > 9 M 8.7 M 5.95 M

100% 100% 82% 40%

N/A N/A 22.43% 15.15%

FSR STATEMENT:PROJECT HAS AN FSR OF 2.72 INCLUDING NO ACCESSORYUSES AND BASED ON SIMILAR MULTIFAMILY ONES.ROOFTOP AMENITY SPACE (EXTERIOR) BUT INCLUDESAMENITY ROOM (INTERIOR) FURTHER BREAKDOWN ISINCLUDED WITH THIS FSR COMPLIANCE DATA.

NUMBER OF DWELLING UNITS: 31 DWELLING UNITS

ScaleCheckedDrawn

Job No.

[email protected]

Vancouver, BC, Canada, V6B 1R8

203 - 128 West Pender Street

Facsimile:

Telephone:

E-mail:

604. 684.3338

604. 684.3600

Revisions

Sheet

Revision

(JDA+P), and cannot be used without the written consent

files or design are and at all times remain the exclusiveAll rights reserved. These drawings, CAD and/ or Revit

property of Johnston Davidson Architecture + Planning Inc.

of JDA+P. These drawings are not valid for constructionwithout the seal of the Architects.

Job Title

Sheet Title

Client

HOUSING6TH FLOOR PLAN

1209

Firehall No.5 +Housing

Vancouver Fire RescueServices + YWCA

JBKJ

3090 East 54th Avenue+ 7001 Kerr Street

1:100

1ISSUED FOR DP - 95%REVIEW 14-JUL-31

2 ISSUED FOR DP - 99%REVIEW

15-FEB-12

3ISSUED FOR DP, REZONINGAPPLICATION 15-FEB-17

scale - 1 : 100

6th floor plan1

3

(INCLUDES ACCESSIBLE DWELLING UNIT - 601)

N

Page 8: PROJECT DATA - PARKING, LOADING, BICYCLES · 2015. 3. 3. · 1.4 m² 15.2 ft² bike area 010 2.1 m² 22.8 ft² bike area 010 5.6 m² 60 ft² ywca bike room 2 020 1200 2321 stair #4

2

HA

HB

HD

HG

H3 H4 H6

HH

H7H1

116.40 m

115.97 m

RD RD RD RD

RDRDRDRD

600MM OFFSETFROM PARAPET

2400 HIGH FENCEGUARD AROUNDPERIMETER OFCOMMON SPACE

7509 9503 9307 9214

CANOPY ROOFEXTENSION FROMFACE OF ELEVATORAND STAIR TOWER.

2A3.8

194 m²2088.5 ft²

amenity space702

PLAY AREA

2188

4

36713

118.73 m

107.23 m

121.13 m

118.83 m

CONCRETEPAVERS

TYP. GARDENINGBOXES @ 600MMHIGH

TYP. PLANTERBOXES @ 600MM

HIGH

1190

7475

1190

7475

ELEVATION OF ALLPARAPETS @116.20M

116.00 mHRV 2 HRV 4

HRV 1

HRV 3

HA

7H6H5

3

A3.8

701

700

9.7 m²104 ft²

elevator lobby700

14.4 m²155.3 ft²

mechanical room701

RD RD

RDRD

DN

12.4 m²133.2 ft²

stair #3S03

2400 HIGH FENCEGUARD AROUNDPERIMETER OFCOMMON SPACE

LINE OF CANOPY ABOVE

702A

702B

COLUMN ROOFSUPPORT

4220

3420

5501

5278

194 m²2088.5 ft²

amenity space702

HRV 4HRV 3

LINE OF CANOPY ABOVE

FLOOR AREAS - ROOF

58.68 M²

194 M²

ROOF - FLOOR AREA

AMENITY ROOFTOP GARDEN

B HA

ROOF LEVELEL. 116.000

TOP OF STAIRCASEEL. 118.400

STEEL POST

STEEL CANOPYFRAMING

5000

ELEV. LOBBY STAIR #3

ScaleCheckedDrawn

Job No.

[email protected]

Vancouver, BC, Canada, V6B 1R8

203 - 128 West Pender Street

Facsimile:

Telephone:

E-mail:

604. 684.3338

604. 684.3600

Revisions

Sheet

Revision

(JDA+P), and cannot be used without the written consent

files or design are and at all times remain the exclusiveAll rights reserved. These drawings, CAD and/ or Revit

property of Johnston Davidson Architecture + Planning Inc.

of JDA+P. These drawings are not valid for constructionwithout the seal of the Architects.

Job Title

Sheet Title

Client

HOUSINGROOF PLAN

1209

Firehall No.5 +Housing

Vancouver Fire RescueServices + YWCA

JBKJ

3090 East 54th Avenue+ 7001 Kerr Street

1:100

1ISSUED FOR DP - 95%REVIEW 14-JUL-31

2 ISSUED FOR DP - 99%REVIEW

15-FEB-12

3ISSUED FOR DP, REZONINGAPPLICATION 15-FEB-17

scale - 1 : 100

roof plan1scale - 1 : 100

roof level - elevator lobby / mechanical plan2

3

NOTE:SEE LANDSCAPE DRAWING L-2

N

roof level - section at canopy3


Recommended