+ All Categories
Home > Documents > ProSoft Technology

ProSoft Technology

Date post: 19-Dec-2021
Category:
Upload: others
View: 5 times
Download: 0 times
Share this document with a friend
108
ProSoft Technology ControlTech CZ Brno 12.2015 Krzysztof Hajzyk Regional Sales Manager Central & Eastern Europe, CIS, Finland ProSoft Technology
Transcript
Page 1: ProSoft Technology

ProSoft Technology ControlTech CZ Brno 12.2015

Krzysztof Hajzyk Regional Sales Manager Central & Eastern Europe, CIS, Finland

ProSoft Technology

Page 2: ProSoft Technology

Where Automation Connects.

General information

Page 3: ProSoft Technology

Who we are…

3

25+ years of experience Solutions linking dissimilar automation products Support from pre-sales through the entire life-cycle of the application Total solutions

Application in every industry 500+ communication modules 100+ industrial communication protocols Global scope Worldwide distribution

Page 4: ProSoft Technology

Close to your customers

Global HQ: ProSoft Technology, Inc. California

Europe, Middle East, Africa HQ: ProSoft Technology SAS France

Latin America

Asia Pacific

Brazil

Sales & Technical

Bakersfield (CA)

Worldwide H.Q.

Toulouse EMEA H.Q.

Poland Sales

Kuala Lumpur AP H.Q.

Singapore Sales

Shanghai Technical

Delhi

Sales

Houston LA H.Q.

North America 8 Sales offices.

Japan Sales

UAE

Sales & Technical

UK Sales

Mexico Sales

Venezuela Sales

Argentina

Sales

Italy Sales

Germany Sales

Technical support included - 3 years warranty - 400+ partners worldwide

Madison Wireless

Page 5: ProSoft Technology

Oil and Gas

Water / Wastewater

Packaging

Energy / Power

Food and Beverage

Automotive

Many more…

Markets Served

Page 6: ProSoft Technology

Where Automation Connects.

MVI56-DNP

Page 7: ProSoft Technology

Hardware Product Solutions

We are Industrial Automation “Translators”

185+ Plug-In Solutions for Rockwell Automation

160+ Industrial Gateway Solutions

40+ Industrial Wireless Solutions

“Where Automation Connects”

Page 8: ProSoft Technology

Where Automation Connects.

Rockwell Automation Solutions

Page 9: ProSoft Technology

Integrated Interface Modules

9

Page 10: ProSoft Technology

Premier Integration Tools

AOP – Add on Profile

AOI – Add on Instruction

Faceplates Free to customers

Displays product diagnostics & configuration for operators and engineers to troubleshoot the process

Works with AOIs – Add on Instructions to get display data

Page 11: ProSoft Technology

EtherNet/IP modules

EtherNet/IP Client/Server Network Interface Module for SLC500, CompactLogix, PLC5, Micrologix 1500 allows:

PLC processors to interface with EtherNet/IP protocol compatible devices and hosts

remote Ethernet programming and troubleshooting

SCADA access

Perfect for:

data with EtherNet/IP PLC’s

Adding additional communication channels

Adding additional subnet access

PLC based interface to DH+/ RIO, DH-485 devices

VPN access

Ethernet programming

Building unified network using ethernet

MVI46-DFNT - MVI69-DFNT

MVI71-DFNT

Page 12: ProSoft Technology

EtherNet/IP module with new PLC

MVI69-DFNT module acts as Client and/or Server on EtherNet/IP network

Support explicit messages (No I/O connection supported)

Typical Applications:

“lock down” the application

separate subnet for communicating with HMI/SCADA host

To HMI/SCADA/PLC

To I/O

To HMI/SCADA/PLC

L4X Processor

L3X Processor

Page 13: ProSoft Technology

PROFIBUS in-chassis solution

PROFIBUS DP Slave Module for CompactLogix, ControlLogix, SLC, Flex I/O, SCANport

PROFIBUS DP field devices

PROFIBUS DP V1 Master module

FDT Communication FactoryTalk Asset Centre FieldCare PSFT comDTM

EtherNet/IP

EtherNet/IP

PCB Communication Module & Network Configuration Diagnostics Network monitoring

Page 14: ProSoft Technology

New Profibus cards for CompactLogix

Programmed by Ethernet Master supports 5700+ bytes IN/OUT Slave supports 244 bytes IN/OUT AOP used for seamless integration Training Video Easy setup

Page 15: ProSoft Technology

… and Modbus for all

Flex I/O

POINT I/O

CompactLogix Micrologix1500

SLC500

PLC5

ControlLogix ControlLogix XT

Page 16: ProSoft Technology

Modbus Serial for CompactLogix P

ERFO

RM

AN

CE

PRICE

ILX34-MBSxxx -CompactLogix L1 & PointIO adapters • 1 serial port • 30 Modbus commands with 35 words of data per command • Configuration stored in processor – Eliminates need to maintain

multiple configuration files • Works with PointIO adapters in distributed IO applications

MVI69L-MBS – suitable for CompactLogix L2 • More cost sensitive smaller applications • 30 Modbus commands, 240/240 words of IO data • Configuration stored in processor • 1 Serial port • Master or Slave

MVI69E-MBS – suitable for CompactLogix L3 • 2 Serial ports/channels • Master and/or Slave • 250 Max Modbus commands per port • 10,000 words of data • For ALL applications

Page 17: ProSoft Technology

Modbus TCP/IP for CompactLogix P

ERFO

RM

AN

CE

PRICE

MVI69L-MBTCP – suitable for CompactLogix L2 • More cost sensitive smaller applications • Multi Client/Multi Server • 10 Server/10 Client simultaneous connections • Up to 16 commands per connection, each fully configurable for function • Configured commands can be directly controlled from Ladder Logix • Error codes available on an individual command basis • 240 words of I/O data

MVI69E-MBTCP – suitable for CompactLogix L3 • Multi Client/Multi Server • 20 Server/20 Client simultaneous connections • Up to 16 commands per connection, each fully configurable for function • Configured commands can be directly controlled from Ladder Logix • Error codes available on an individual command basis • 10,000 words of I/O data

Page 18: ProSoft Technology

C/C++ Programmable module

MVI56E-LDM

C programmable modules based on Linux Key Features:

2 Ethernet Ports

Free VMWare image with preconfigured programming environment

C programmable modules based on Linux Key Features:

2 Serial Ports

1 Ethernet Ports

Free VMWare image with preconfigured programming environment

MVI69E-LDM

Page 19: ProSoft Technology

Powerful option for custom applications requiring ControlLogix and CompactLogix connectivity

Why you should use LDM card?

Protect Know How

Lock application

Additional features like adapting PID generated form MatLAB

Specific communication code

LDM as coprocessor

Linux based system

Special development for Ethernet or serial connectivity

C/C++ Programmable module

Page 20: ProSoft Technology

Where Automation Connects.

Gateways

Page 21: ProSoft Technology

Gateways – 60+ protocols

Page 22: ProSoft Technology

Smart protocol gateways

Features and Benefits:

High performance gateway:

Supports multiple IO connections

Allows combination of PLC/PAC to communicate with various end devices

Bi-directional data transfer

Cost effective & easy to configure

Built in SD card slot for config files

Page 23: ProSoft Technology

Smart protocol gateways

ETHERNET/IP MODBUS TCP/IP

EtherNet/IP to Modbus TCP/IP Modbus TCP/IP to Modbus Serial

EtherNet/IP to Modbus Serial Modbus TCP/IP to Modbus Serial 4 Port

EtherNet/IP to Modbus Serial 4 Port ModbusTCP/IP to SIE (Siemens Industrial Protocol)

EtherNet/IP to ASCII ModbusTCP/IP to Profinet*

EtherNet/IP to ASCII 4 Port Modbus Serial to Profinet*

EtherNet/IP to SIE Modbus Serial to Profinet 4 Port*

EtherNet/IP to Profinet

* New product

Protocols Supported

Page 24: ProSoft Technology

PLX30 EtherNet/IP to SIE

Allows EtherNet/IP and Modbus TCP devices to interface easily with multiple S7-200, S7-1200, S7-300, and S7-400 PLCs.

The multi-Client module improves performance when exchanging data with multiple S7 CPUs on a single network, by supporting up to 20 Clients.

Supported register types: DB, Inputs, Outputs, Flags, Counters, Timers

Key benefits

Page 25: ProSoft Technology

Profinet gateway

EtherNet/IP to Profinet Device

Embedded EDS Add-On Profile

No ladder programming is required when using I/O connections.

Multiple I/O connections

Communication via an I/O connection

SD card slot (SD card optional)

Video setup tutorial provided at psft.com/Ap5

Page 26: ProSoft Technology

EtherNet/IP to Modbus TCP/IP

PLX32-EIP-MBTCP

EtherNet/IP to Siemens IE

PLX32-EIP-SIE

EtherNet/IP to PROFINET

PLX32-EIP-PND

Modbus TCP/IP to Siemens IE

PLX32-MBTCP-SIE

Modbus TCP/IP to PROFINET

PLX32-MBTCP-PND

26

PLX32

Page 27: ProSoft Technology

Difference from PLX31

Two Ethernet ports Each Ethernet port has to operate on a different network.

Modbus TCP EtherNet/IP

PLX32-EIP-MBTCP

ControLogix

10.1.2.15 192.168.1.50

10.1.2.15 10.1.2.105

Page 28: ProSoft Technology

PROFIBUS

ETHERNET

FDT Communication FactoryTalk Asset Centre FieldCare PSFT comDTM

PROFIBUS DP V1 MASTER

PROFIBUS DP V0 Slave to: • HART • ASCII • DNP3 • IEC 60870-5-101 • IEC 60870-5-103 • IEC 60870-5-104 • MODBUS • DH485 • DF-1 • and many more...

PROFIBUS DP V0 Slave to: • BACnet • LONworks • XML • METASYS • Controlnet • DeviceNet • and many more...

Our PROFIBUS solutions

PROFIBUS DP Slave Module for CompactLogix, ControlLogix, SLC, Flex I/O, SCANport

In-chassis solutions For Rockwell Automation

Stand alone gateways

Page 29: ProSoft Technology

IEC 61850

DNP 3.0

DNP 3.0 over Ethernet

IEC 60870-5-101

IEC 60870-5-103

IEC 60870-5-104

Modbus TCP/IP

Our Energy Solutions

Page 30: ProSoft Technology

30

Application reference - Energy

Application description: ControlTech InForm Technologies (IFT), Slovakia EU mandate 20% of all energy from renewable sources until 2020 Alternative energies: Remote control and data transfer from renewable sources to dispatching distribution companies

Customer needs: Collect data from electricity meters and other devices using IEC60870-5-101 protocol Send back all the information to power distribution company

Page 31: ProSoft Technology

31

GSM Modem

GPRS

SCADA in

distribution

company

Allen Bradley, Prosoft IEC60870-5-101 Slave Communication Module

MLX1500 or

CPX L23

Application reference - Energy

Our solution: MVI69-101S (IEC 60870-5-101 Slave Communication Module)

Benefits:

Fast Implementation IEC 60870-5-101 Protocol Compliant Easy extension for other networks Energy monitoring certificated Fully automatic & autonomous

Page 32: ProSoft Technology

Factory utilities

Energy management

Data centres

Life safety & fire alarm systems (gas leak detection)

Legacy Networks

Chillers, boilers, UPS, VFD…

Over 100 dedicated protocols:

Quick Server Stand-alone gateway Slot Server In-rack module

BTL Mark

LONwork certified

JCI Metasys® N2

Page 33: ProSoft Technology

Where Automation Connects.

Migration solutions

Page 34: ProSoft Technology

Why we migrate to new…

New possibilities

New media has to be

connected

Lack of interfaces

Warranty Spare parts not available

Spare parts expensive

Modern programming

software

New OS support

Page 35: ProSoft Technology

Migration solutions

Phase migration

Life cycle extension

Page 36: ProSoft Technology

DH+ & RIO solutions

Page 37: ProSoft Technology

DH+ programming

Connect a Data Highway Plus Network to EtherNet/IP PLC

PLC-5

AN-X2-AB-DHRIO EtherNet/IP

DH+

RSLogix5 Programming station CompactLogix

Page 38: ProSoft Technology

HMI over DH+

AN-X2-AB-DHRIO

EtherNet/IP

Blue Hose

DH+

PanelView Plus 6** PLC5

DH+ to Ethernet/IP HMI

Upgrade your HMIs without replacing your Control System

Migrate to the latest PanelView Plus 6/7 products

**PanelView Standard in Silver Series

End of year deadline

All AN-X2-AB-DHRIO will have chance to be upgraded It works with PLC5 only

Page 39: ProSoft Technology

Ghost mode

Tag generation

Automated baud rate detection

Keep RIO IO’s

AN-X2-AB-DHRIO

Remote I/O

CompactLogix

Page 40: ProSoft Technology

New PVP or PF over RIO

AN-X2-AB-DHRIO

Blue Hose

AB Remote I/O EtherNet/IP

PLC5 PowerFlex Drive

AN-X2-AB-DHRIO

EtherNet/IP

Blue Hose

AB Remote I/O

PanelView Plus 6/7 PLC5

Remote I/O Adapter to Ethernet/IP HMI

Upgrade your HMIs without replacing your Control System

Migrate to the latest PanelView Plus 6 products

A-B Remote I/O Adapter to EtherNet/IP Drives

Connect up to 4 EtherNet/IP drives to an existing Remote I/O Network

Page 41: ProSoft Technology

1794-AENT

RIO Flex I/O

1794-ASB (Remote I/O Flex adapter) has been

discontinued by Rockwell. The replacement

1794-AENT/R is an EtherNet/IP adapter.

AN-X2-AB-DHRIO EtherNet/IP Blue Hose

AB Remote I/O

1794-ASB

Page 42: ProSoft Technology

Specifications

Flex I/O Migrations only Does not work with SLC I/O, 1771 I/O, Point I/O, etc.

Supports the following Flex I/O modules

AENT, OW8, IA8I, OA8I, OB8, OB16, OB16P, IB16, IE8, IE4XOE2, OE4, IR8, IRT8, OA8, OA16, OB8EP, OB16D, OB32P, OC16, OG16, OM8, OM16, OV16, OV16P, OV32, IA8, IA16, IC16, IB32, IV32, IB8, IB8S, IM8, IG16, IH16, IM16, IB16D, IV16, IB16XOB16P, IB10XOB6, IE12, OE12, IE8XOE4, IR8B, IT8

Supports up to 16 EtherNet/IP Connections Each adapter and up to 8 (*)discreet I/O modules count as a single

connection – *32 point discrete modules each counts as a single connection

Each analog module counts as a single connection

Page 43: ProSoft Technology

Examples

1 analog input, 1 analog output, 2 digital inputs, 1 digital

output

3 connections

3 digital inputs, 2 digital output

1 connections

2 Analog input, 1 Analog output

4 connections

Page 44: ProSoft Technology

Where Automation Connects.

Solutions for migration to different

media type

EtherNet/IP over Blue Hose

Page 45: ProSoft Technology

Huge install base of Allen Bradley Remote I/O Systems

Huge installed base

Most of the products pictured above are either Silver Series or Discontinued

Page 46: ProSoft Technology

300m Remote I/O

150m

120m 90m

Communication on long distance

Remote I/O networks have been installed for many years and typically run long distances

Page 47: ProSoft Technology

You already got cables

Page 48: ProSoft Technology

Migration solutions

EIP

Repurposed Remote I/O Cable

RIO RIO

EIP Master Slave

Drop Drop

Trunk

Page 49: ProSoft Technology

Allen Bradley RIO Before

Cabinet 1 Cabinet 2 Cabinet 3

Remote I/O Blue Hose

Page 50: ProSoft Technology

EtherNet/IP After

Repurposed Blue Hose

EIP

EIP

Cabinet 1 Cabinet 2 Cabinet 3

EIP EIP

Page 51: ProSoft Technology

Where Automation Connects.

Wireless solutions

Page 52: ProSoft Technology

Industrial wireless solutions

Don’t say NO to wireless just because you don’t KNOW wireless...Talk to ProSoft Technology!

WHY USE WIRELESS?

Save money by saving time

Save money reducing plant wiring costs

Communication to moving/spinning equipment

Harsh environment communications

Remote access for mobile workers

Wireless as an alternative to Leased Telephone Line

Remote access for data recording, alarms follow-up, programming

Page 53: ProSoft Technology

RF transmitted through slots cut into the shield (under the insulation)

Acts as a long, flexible antenna

Provides uniform RF signaling along monorail tracks

Solves line-of-sight challenges in corridors and tunnels

Supports 802.11 2.4 GHz and 5 GHz wireless systems

Introducing a NEW antenna

Page 54: ProSoft Technology

Where Automation Connects.

Radiating Cable

Applications

Page 55: ProSoft Technology

Radiating Cable Typical applications

Communication inside a rail tunnel, road tunnel, subway

But today leaky cable is also used for other types of mobile applications :

♦ Distribution warehouse ♦ Cranes in aluminum plant ♦ Baggage handling system ♦ Funiculars ♦ Trolleys ♦ Monorail ♦ Conveyors ♦ Rotating

machines ♦ Slip ring communication replacement ♦ Mobile application with I/O communication ♦ …

Page 56: ProSoft Technology

Metal environment

Warehouse : wireless connectivity for mobile workers,

AGV, conveyors,…

Cranes inside the building, cranes for aluminum

production, …

Benefits :

• Metal environment is not an issue

• Easy to install

• No wave outside your building.

Page 57: ProSoft Technology

Patch Antenna Solution

Radiating Cable

Rackstacker

Page 58: ProSoft Technology

Application description

Material handling for warehouses and stocks.

Application requirements

A lot of metal frames

Moving part

Metal moving parts (cabinets) between rows of the warehouse)

Reliability, availability (moving cabinet must not lose connection when at stop points).

Location

Dornach, Switzerland

Easier to implement

Application description

Material handling for warehouses and stocks.

Application requirements

A lot of metal frames

Moving part

Metal moving parts (cabinets) between rows of the warehouse)

Reliability, availability (moving cabinet must not lose connection when at stop points).

Location

Dornach, Switzerland

Page 59: ProSoft Technology

Replace old DH+ netwwork

Monorail System

20 carriers Monorail track

100 m

120 m

carriers

Load Unload

Process building

Ford St Petersburg Vsevolozhsk facility. The RadioLinx Automation-class wireless solution from ProSoft Technology, allowed the number of carriers simultaneously in use over the loop in the paint-shop, to grow from 13 up to 20. Almost 54% increase!

Migrating DH+ to EtherNet/IP and slip-ring to RadioLinx network

Page 60: ProSoft Technology

Better realibity

RadioLinx® 802.11n Industrial Hotspot RLXIB-IHN

RadioLinx® 802.11n Industrial Client RLXIB-ICN

100 meters of leaky cable LCK5100

100 meters of leaky cable LCK5100

Page 61: ProSoft Technology

Rotating machines

All types of rotating machines :

carousels, entertainment equipments,

typical applications with slip ring

communication replacement

Benefits :

Near field application : only few centimeters between mobile antenna and the leaky cable. clear line of sight guaranteed !

Page 62: ProSoft Technology

Where Automation Connects.

RLX2

radio family

Page 63: ProSoft Technology

802.11abgn Fast Industrial Hotspot

High speed 802.11n technology

Channel Bonding & MIMO Antenna (2 streams)

Up to 300 Mbps RF data rate

2.4 GHz or 5 GHz band – including DFS channels

Optimized for Ethernet IO & Producer/Consumer systems

Ch. 36 Ch. 40

40MHz

Bonded

20MHz 20MHz

Stream 1

Stream 2

Multiple Data Streams (MIMO) Multiple Channels (Bonding)

Page 64: ProSoft Technology

802.11abg Industrial Hotspot

High speed 802.11abg technology

Up to 54 Mbps RF data rate

2.4 GHz or 5 GHz band

For general usage

Page 65: ProSoft Technology

RLX2 Family Features

Fast roaming with full bridging

Free OPC server

IGMP snooping/packet filtering

Serial communication transparent or with Modbus and DNP ethernet encapsulation

Possibility to mix 802.11abg and 802.11n radios in one network

SD recovery card

Page 66: ProSoft Technology

ProSoft FAST ROAM Technology

Fast Roam between Access Points

Page 67: ProSoft Technology

New firmware for RLX2 radios

This is a field upgradable firmware update for the

RLX2-IHx Wi-Fi 802.11 products

RLX2-IHA

RLX2-IHG

RLX2-IHW

RLX2-IHNF

RLX2-IHNF-W

RLX2-IHNF-WC

Page 68: ProSoft Technology

New firmware for RLX2 radios

Firmware version v36 – Key new features:

Ultra-fast roaming > 10ms switch over time between

ProSoft Technology radio masters

Multi-Ethernet device support in client mode – Bridge

multiple Ethernet devices (PLC, drives, HMI, etc)

when connecting to non-ProSoft radio infrastructure.

EtherNet/IP object / Modbus agent & SNMP – Radio

diagnostics available in the PLC and using common

IT tools.

New user interface – Uses a tabbed interface to

simplify settings & shorten configuration time.

Page 69: ProSoft Technology

New firmware for RLX2 radios

All RLX2 802.11 type radios could be upgraded

Availability January 2016

Beta tests available now

Page 70: ProSoft Technology

Radiating Cable System

802.11abgn Fast Industrial Hotspot Performance

2 RC segments per radio (up to 125m per segment)

Fast Roam support

Less than 50 ms (10ms in new formware) transfer time between masters

Up to 150 Mbps

Page 71: ProSoft Technology

Industrial Cellular Gateway

Supports 3G cellular networks worldwide

Secure VPN connections

Simultaneous Ethernet & Serial connections

On-board discrete & analogue IO to remotely monitor alarm status

Integrated GPS for location based monitoring

AOP for easy integration in to RSLogix/Studio5000

Page 72: ProSoft Technology

Applications

Location status alerts

• GPS tracking of mobile assets

• Remote status alerts

• Telemetry/telematics

OEM monitoring applications

• OEM monitoring of a machine at customers site

• External VPN to customer IT network

• Secure network

Remote water utility applications

• PLC to remote serial device

• Remote access

Page 73: ProSoft Technology

Where Automation Connects.

Wireless I/O

Page 74: ProSoft Technology

Wireless I/O

What it is and what it is not:

Replaces traditional I/O wiring runs

Made for monitoring and simple controls – not high

speed I/O

Not networked I/O, needs I/O interfaces at PLC, RTU

etc.

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Bi-Directional

Page 75: ProSoft Technology

Typical Industries / Applications

Water / Waste Water

Mining

Oil and Gas

Remote Operator Call Stations

Machine Monitoring

Makes the Job Easier for Electricians!

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 76: ProSoft Technology

Wireless I/O Benefits

Avoid Trenching

Avoid Conduit & Wire Burial

Avoid Permitting

Avoid Extra Labor

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

No Software or Programming Required

Page 77: ProSoft Technology

2x Radio Modules (paired)

2x DataRails™

4x End Terminal Brackets

2x Slot Covers

1x USB to Mini USB Cable

Quick Start Guide

Supports Up to 5 I/O Pairs

Radio Kit

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

BM-0900-RM1K (900MHz)

BM-0915-RM1K (915MHz Australia)

BM-2400-RM1K (2.4GHz)

Page 78: ProSoft Technology

Antenna and Cable Sold Separately

ProSoft distributors will help you select the Antenna,

Cable and Lightning Arrestor for your application

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 79: ProSoft Technology

All I/O Modules Provide Isolation 2500 V r.m.s.

I/O Modules

3-30 VDC Digital

4 In / 4 Out

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

4-20mA Analog

2 In / 2 Out

0-10 V Analog

2 In / 2 Out

Page 80: ProSoft Technology

System supports up to 16 Pairs*

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

* Number of I/O modules limited by

backplane power. Consult power budget

calculator.

Page 81: ProSoft Technology

Specifications

US/North Am: 900 MHz, 250mW

Up to 4 miles

US/International: 2.4 GHz (2400 MHz) 63mW US, 10mW International

Up to 1 mile

Australian: 915 MHz

Up to 6.5 km

Receiver Sensitivity: 900 MHz -101dBm, 2.4 GHz -100 dBm

RF Security: 128 bit AES

Operational Temp: -40C to 85C

Environmental: UL Class 1 Div 2, ATEX Zone 2

All Boards Conformal Coated

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 82: ProSoft Technology

Number of Modules

Turbo Speed Default Speed

1 100 ms 1 sec

2-3 200 ms 1 sec

4 250 ms 1 sec

5-6 333 ms 1 sec

7-11 500 ms 1 sec

12-16 1 second 1 sec

I/O Update Rate

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 83: ProSoft Technology

Attach DataRail™

Simple Installation

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 84: ProSoft Technology

Attach End Terminal Bracket

Simple Installation

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 85: ProSoft Technology

Attach Radio & Antenna

Simple Installation

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 86: ProSoft Technology

Attach I/O Module(s)

Simple Installation

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 87: ProSoft Technology

Attach I/O Module(s)

Simple Installation

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 88: ProSoft Technology

Attach End Terminal Bracket & Cover

Simple Installation

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 89: ProSoft Technology

Repeat Same Steps

Simple Installation

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 90: ProSoft Technology

0 1

2

Match Switch Settings

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 91: ProSoft Technology

9-30 V COM

Reduced Power Wiring

Single Power Termination Powers All I/O Modules

Accepts 9-30 VDC – Good for Battery / Solar Sites

Reverse Polarity Protected

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 92: ProSoft Technology

Outputs to PLC input modules

Input devices / Transmitters

Output devices / Valves

PLC output modules to

Inputs

Inputs and Outputs in each module

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 93: ProSoft Technology

SCADA /

PLC

I/O Link Failure

RF Link Failure

Radio Diagnostics

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

LED Indicators for

RF and I/O Health

Radio reports loss of I/O comms or RF link comms

When RF Link or I/O Link Failure is Detected System Automatically Switches to Fail Safe Mode

Page 94: ProSoft Technology

Digital

Off/Disabled – Reports last known value

On/Enabled – Choose on or off position

Fail Safe DIP Switches

Fail Safe I/O Settings

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Analog

Outputs Lowest Value, 0V or 4mA

Or Set to Any Value on Scale Using

Advanced User Interface

Page 95: ProSoft Technology

Manual Fail Safe Function

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 96: ProSoft Technology

Advanced User Interface

Mini USB Port

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Free PC base software for advanced functions

Download from ProSoft Wireless I/O Product Page

Page 97: ProSoft Technology

Check RF Strength

Adjust Tx Power

Change RF Timeout Interval

Advanced User Interface

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 98: ProSoft Technology

Check RF Strength

Adjust Tx Power

Change RF Timeout Interval

Check Inputs and Outputs

Advanced User Interface

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 99: ProSoft Technology

• Check RF Strength

• Adjust Tx Power

• Change RF Timeout Interval

• Check Inputs and Outputs

• Force Local Outputs

Advanced User Interface

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 100: ProSoft Technology

Check RF Strength

Adjust Tx Power

Change RF Timeout Interval

Check Inputs and Outputs

Force Local Outputs

Set Fail Safe Values for Analog

Modules

Advanced User Interface

Copyright ©2015 ProSoft Technology, Inc. All rights Reserved. COMPANY CONFIDENTIAL

Page 101: ProSoft Technology

Where Automation Connects.

Technical Support

Page 102: ProSoft Technology

The solution is not only radio module

Wireless is easy …

The solution is not only solved by choosing the radio module. Cables, Antennas, Splitters, Lightning Protection, etc., build the whole solution. Wrong choices can generate a lot of problems.

Page 103: ProSoft Technology

Where to start?

Collect the information on the application:

Simple word doc – Customer to complete

Get a plant layout

Google Earth

Drawings/sketches

Page 104: ProSoft Technology

What’s next? Wireless designer

ProSoft Technology Wireless Designer (PWD):

Help you in defining the architecture

Data from the collection form

BOM generator

Page 105: ProSoft Technology

What’s next? Site study

Site study:

Can be done by non radio expert.

To identify antennas position, numbers of repeaters, feasibility, power requirements…

Guide for the design of the network, bill of materials, report…

TIP: • Clear Line of sight – KEY POINT • inSSIDer from MetaGeek • Radio Browser – available parents • Take pictures of the positions • Record the information • Write the report

Page 106: ProSoft Technology

What next? Site Survey

Site survey:

Requires a radio expert with the specific measuring systems

Analyse frequency bandwidth, signals, networks…

On site assistance during your project commissioning

Page 107: ProSoft Technology

Questions?

Page 108: ProSoft Technology

Contact Details

Krzysztof Hajzyk Regional sales manager – Central & Eastern Europe, Russia, CIS, Finland

+48 600 414 565

EMEA [email protected]

www.prosoft-technology.com

ProSoft Technology Kamionkowska 45A

03-812 Warsaw

POLAND


Recommended