7
1 of 7 ® *Assembled in the USA using domestic and foreign parts INCLUDES: Two-Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/French/ Portuguese) With External Viewing Window for Easy Indication of Generator Status and Breaker Position. Electronic Engine Control Module Optimized for Power Generating. Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System Smart Battery Charger UV/Ozone Resistant Hoses ±1% Voltage Regulation Field Convertible Fuel Type With No Mechanical Adjustment Required. 5 Year Limited Warranty UL 2200 Listed Protector ® Series Standby Power Rating Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz Protector® Series Meets EPA Emission Regulations FEATURES INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. TEST CRITERIA: PROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. PROTECTOR® SERIES Standby Generators Liquid-Cooled Gaseous Engine *Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes.
Transcript
Page 1: Protector o t c e t o Series · Internal Fault Protection ... Wi-Fi LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP

1 of 7

®

*Assembled in the USA using domestic and foreign parts

INCLUDES: Two-Line LCD Multilingual Digital Evolution™

Controller (English/Spanish/French/Portuguese) With External Viewing Window for Easy Indication of Generator Status and Breaker Position.

Electronic Engine Control Module Optimized for Power Generating.

Isochronous Electronic Governor

Sound Attenuated Enclosure

Closed Coolant Recovery System

Smart Battery Charger

UV/Ozone Resistant Hoses

±1% Voltage Regulation

Field Convertible Fuel Type With No Mechanical Adjustment Required.

5 Year Limited Warranty

UL 2200 Listed

Protector® Series

Standby Power Rating Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz

Prot

ecto

r® S

erie

s

Meets EPA Emission Regulations

FEATURES INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of

GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’tstop there. Total commitment to component testing, reliability testing,environmental testing, destruction and life testing, plus testing toapplicable CSA, NEMA, EGSA, and other standards, allows you to chooseGENERAC POWER SYSTEMS with the confidence that these systems willprovide superior performance.

SOLID-STATE, FREQUENCY COMPENSATED VOLTAGEREGULATION. This state-of-the-art power maximizing regulation system isstandard on all Generac models. It provides optimized FAST RESPONSE tochanging load conditions and MAXIMUM MOTOR STARTING CAPABILITYby electronically torque-matching the surge loads to the engine. Digitalvoltage regulation at ±1%.

TEST CRITERIA:

PROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY

SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealernetwork provides parts and service know-how for the entire unit, from theengine to the smallest electronic component.

GENERAC TRANSFER SWITCHES. Long life and reliability aresynonymous with GENERAC POWER SYSTEMS. One reason for thisconfidence is the GENERAC product line is offered with its own transfersystems and controls for total system compatibility.

PROTECTOR® SERIESStandby Generators

Liquid-Cooled Gaseous Engine

*Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes.

Page 2: Protector o t c e t o Series · Internal Fault Protection ... Wi-Fi LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP

2 of 7

®

application & engineering data48 kW

ENGINE SPECIFICATIONS: 48 kWMake Generac

Model Inline 4 cylinder

Cylinders 4

Displacement (Liters) 4.5

Bore (in/mm) 4.5/114.3

Stroke (in/mm) 4.25/107.95

Compression Ratio 9.9:1

Intake Air System Naturally Aspirated

Lifter Type Hydraulic

ENGINE LUBRICATION SYSTEMOil Pump Type Gear

Oil Filter Type Full Flow Spin-On Cartridge

Crankcase Capacity (qt/l) 11.6/11 (48 kW)

ENGINE COOLING SYSTEMType Ethylene Glycol 50/50 Mix

Water Pump Belt-Driven

Fan Speed (rpm) 2,100

Fan Diameter (in/mm) 20

Fan Mode Pusher

FUEL SYSTEMFuel Type Natural Gas, Propane Vapor

Fuel Shut Off Solenoid Standard

Operating Fuel Pressure3.5-14 Water Column/9-26 mm

HG

LP Fuel Pressure 7 - 14" Water Column

NG Fuel Pressure 3.5 - 14" Water Column

ENCLOSURE FEATURES

Aluminum weather protectiveenclosure

Ensures protection against mother nature.Electrostatically applied textured epoxy paint for added durability.

Enclosed critical grade muf-fler

Quiet, critical grade muffler is mounted inside the unit toprevent injuries.

Small, compact, attractive Makes for an easy, eye appealing installation.

SAE Sound attenuated enclosure ensures quiet operation.

GENERATOR FEATURESRevolving field heavy duty generatorDirectly connected to the engineOperating temperature rise 120 °C above a 40 °C ambientClass H insulation is NEMA ratedClass F insulation is NEMA ratedAll models fully prototyped tested

ELECTRICAL SYSTEMBattery Charge Alternator 12 Volt 30 Amp

Static Battery Charger 2.5 Amp

Recommended Battery (battery not included) Group 27F (48kW), 725CCA

System Voltage 12 Volts

GOVERNOR SPECIFICATIONSType Electronic

Frequency Regulation Isochronous

Steady State Regulation ± 0.25%

VOLTAGE REGULATIONType Electronic

Sensing Single Phase

Regulation ± 1%

GENERATOR SPECIFICATIONSType Synchronous

Rotor Insulation Class F (48 kW)

Stator Insulation Class H

Telephone Interference Factor (TIF) <50

Alternator Output Leads 1-Phase 4 wire

Alternator Output Leads 3-Phase 6 wire

Bearings Sealed Ball

Coupling Flexible Disc

Excitation System Direct

(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)

Prot

ecto

r® S

erie

s

Page 3: Protector o t c e t o Series · Internal Fault Protection ... Wi-Fi LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP

3of 7

®

GENERATOR OUTPUT VOLTAGE/kW - 60 Hz

kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both)

RG048

120/240 V, 1Ø, 1.0 pf 48 200 48 200 200

120/208 V, 3Ø, 0.8 pf 48 167 48 167 175

120/240 V, 3Ø, 0.8 pf 48 144 48 144 150

277/480 V, 3Ø, 0.8 pf 48 72 48 72 80

operating data48 kW

ENGINE FUEL CONSUMPTION

Natural Gas Propane

(ft³/hr) (m³/hr) (gal/hr) (ft³/hr) (l/hr)

RG048

Exercise cycle — — — — —

25% of rated load 201 5.7 2.88 104.7 10.9

50% of rated load 336 9.5 4.16 151.3 15.7

75% of rated load 447 12.7 5.28 192 20

100% of rated load 604 17.1 6.61 240.4 25

SURGE CAPACITY IN AMPS

Voltage Dip @ < .4 pf

15% 30%

RG048

120/240 V, 1Ø 100 300

120/208 V, 3Ø 118 242

120/240 V, 3Ø 97 189

277/480 V, 3Ø 63.6 122.8

Note: Fuel p ipe must be s ized for fu l l load.

For Btu content, multiply ft³/hr x 2520 (LP) or ft³/hr x 1000 (NG)

For megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG)

Refer to “Emissions Data Sheets” for maximum fuel flow for EPA and SCAQMD permitting purposes.

STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.

Prot

ecto

r® S

erie

s

Page 4: Protector o t c e t o Series · Internal Fault Protection ... Wi-Fi LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP

4 of 7

®

operating data48 kW

ENGINE COOLING48 kW

Air Flow (inlet air including alternator and combustion air in cfm/cmm) 2,829/80.1

System Coolant Capacity (gal/liters) 2.9/11

Heat Rejection to Coolant (BTU per hr/MJ per hr) 201,060

Maximum Operation Air Temperature on Radiator (°C/°F) 60/150

Maximum Ambient Temperature (°C/°F) 50/140

COMBUSTION REQUIREMENTSFlow at Rated Power (scfm/cmm) 92.7/2.6

SOUND EMISSIONSSound Output in dB(A) at 23 ft (7 m) With Generator in Exercise Mode* 68

Sound Output in dB(A) at 23 ft (7 m) With Generator Operating at Normal Load* 70

EXHAUSTExhaust Flow at Rated Output (scfm/cmm) 104/10.6

Exhaust Temperature at Muffler Outlet (°C/°F) 507/945

ENGINE PARAMETERSRated Synchronous rpm 1,800

POWER ADJUSTMENT FOR AMBIENT CONDITIONSTemperature Deration .................................................................................................................... 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °FAltitude Deration............................................................................................................................1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft

CONTROLLER FEATURESTwo-Line Plain Text LCD Display.............................................................................................................................................Simple user interface for ease of operation.Mode Switch: Auto ..................................................................................................................................................... Automatic Start on Utility failure. 7 day exerciser

Off .................................................................................................................................Stops unit. Power is removed. Control and charger still operate.Manual .................................................................................................Start with starter control, unit stays on. If utility fails, transfer to load takes place.

Programmable Start Delay Between 10-30 Seconds......................................................................................................................................................... 10 sec standardEngine Start Sequence...............................................................................................................................Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)Engine Warm-up.............................................................................................................................................................................................................................. 5 secEngine Cool-Down.......................................................................................................................................................................................................................... 1 minStarter Lock-Out. ........................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped.Smart Battery Charger.................................................................................................................................................................................................................StandardAutomatic Voltage Regulation With Over and Under Voltage Protection ........................................................................................................................................StandardAutomatic Low Oil Pressure Shutdown ........................................................................................................................................................................................StandardOverspeed Shutdown ....................................................................................................................................................................................................... Standard, 72 HzHigh Temperature Shutdown ...................................................................................................................................................................................................... StandardOvercrank Protection...................................................................................................................................................................................................................StandardSafety Fused...............................................................................................................................................................................................................................StandardFailure to Transfer Protection ......................................................................................................................................................................................................StandardLow Battery Protection ................................................................................................................................................................................................................Standard50 Event Run Log .......................................................................................................................................................................................................................StandardFuture Set Capable Exerciser...................................................................................................................................................................................................... StandardIncorrect Wiring Protection ........................................................................................................................................................................................................ StandardInternal Fault Protection ..............................................................................................................................................................................................................StandardCommon External Fault Capability...............................................................................................................................................................................................StandardGovernor Failure Protection........................................................................................................................................................................................................ Standard

Prot

ecto

r® S

erie

s

Page 5: Protector o t c e t o Series · Internal Fault Protection ... Wi-Fi LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP

5of 7

®

available accessories48 kW

Model # Product Description

G0071690Mobile Link® 4G LTE Cellular Accessory

Generac’s Mobile Link allows you to check the status of your generator from anywhere thatyou have access to an Internet connection from a PC or with any smart device. You will evenbe notified when a change in the generator’s status occurs via e-mail or text message. Note:Harness Adapter Kit required.Available in the U.S. only.

G006478-0Kit, Adapter Mobile Link L/C (Required for QT andRG Series)

The Harness Adapter Kit is required to make liquid-cooled units compatible with MobileLink™

G007992-0 Cold Weather KitIf the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into thewrap.

G007990-0 Extreme Cold Weather KitRecommended where the temperature regularly falls below 32 °F (0 °C) for extended periodsof time. For liquid cooled units only.

G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris.

G005703-0 - Bisque Paint KitIf the generator enclosure is scratched or damaged, it is important to touch-up the paint toprotect from future corrosion. The paint kit includes the necessary paint to properly maintainor touch-up a generator enclosure.

G007991-0Scheduled Maintenance Kit

The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to performcomplete maintenance on Generac liquid-cooled generators.

G006664-0 Local Wireless MonitorCompletely wireless and battery powered, Generac's wireless remote monitor provides youwith instant status information without ever leaving the house.

G006665-0Wireless Remote Extension Harness

Recommended for use with the Wireless Remote on units up to 60 kW, required for use onunits 70 kW or greater.

G007993-0 E-StopE-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergen-cy.

G007005-0Wi-Fi LP Fuel LevelMonitor

The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LPfuel tank. Monitoring the LP tank’s fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are availablethrough a free application to notify when your LP tank is in need of a refill.

G007000-0 (50 amp)G007006-0(100 amp)

Smart Management Module

Smart Management Modules (SMM) are used to optimize the performance of a standbygenerator. They manage large electrical loads upon startup and shed them to aid in recovery when overloaded. In many cases, using SMM’s can reduce the overall size andcost of the system.

A0000018981 Ultrasonic Cleaner Solution

An ultra-concentrated anti-corrosive cleaning solution engineered to reach the smallestcavities to clean the toughest contaminants. This water based formula is non-toxic, biodegradable, safe for both metal and plastic surfaces and is superior in rinsability.

A0000019001 Corrosion Inhibitor & Protectant

A plastic, rubber, leather, and vinyl surface protectant designed for use following a thorough cleaning with the A0000018981 Ultrasonic Cleaner Solution. It helps protectedsurfaces stay clean longer as a dry lubrication, polish, and wax. Aids in snow and grassrelease and odor control.

Prot

ecto

r® S

erie

s

Page 6: Protector o t c e t o Series · Internal Fault Protection ... Wi-Fi LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP

6 of 7

®

2119

[83.

4]O

VER

ALL

LEN

GTH

1212

[47.

7]D

OO

R T

YP

888

[35.

0]O

VER

ALL

WID

TH

2026

[79.

8] T

YP58 [2

.3]

TYP

47 [1.8

]31

8[1

2.5]

65 [2.6

]

1168

[46.

0]O

VER

ALL

HEI

GH

T

843

[33]

CEN

TER

OF

GR

AVIT

Y(S

EE N

OTE

5)

WEI

GH

T D

ATA

ENG

INE/

KWEN

CLO

SUR

EM

ATER

IAL

WEI

GH

TG

ENSE

T O

NLY

KG [L

BS]

WEI

GH

T SH

IPPI

NG

SKI

DKG

[LBS

]

SHIP

PIN

G W

EIG

HT

KG [L

BS]

4.5L

/48K

WAL

808

[178

1]51

[112

]85

9 [1

893]

SER

VIC

E IT

EM4.

5L

OIL

FIL

L C

AP L

EFT

SID

EO

IL D

IP S

TIC

KLE

FT S

IDE

OIL

FIL

TER

LEFT

SID

EO

IL D

RAI

N H

OSE

RIG

HT

SID

ER

ADIA

TOR

DR

AIN

HO

SER

IGH

T SI

DE

CO

OLA

NT

REC

OVE

RY

BOTT

LER

IGH

T SI

DE

RAD

IATO

R F

ILL

CAP

RO

OF

TOP

AIR

CLE

ANER

ELE

MEN

TLE

FT S

IDE

SPAR

K PL

UG

SLE

FT S

IDE

MU

FFLE

RSE

E N

OTE

11

DR

IVE

BELT

EITH

ER S

IDE

BATT

ERY

LEFT

SID

E

NO

TES:

1. M

INIM

UM

REC

OM

MEN

DED

CO

NC

RET

E PA

D S

IZE

IS 6

" OFF

SET

OF

OVE

RAL

L LE

NG

TH A

ND

WID

TH O

F G

ENER

ATO

R. {

1193

.8 (4

7") W

IDE

X 24

23.2

(95.

4") L

ON

G}.

REF

EREN

CE

IN

STAL

LATI

ON

GU

IDE

SUPP

LIED

WIT

H T

HE

UN

IT F

OR

CO

NC

RET

E PA

D G

UID

ELIN

ES.

REF

EREN

CE

MAN

UFA

CTU

RER

'S S

PEC

IFIC

ATIO

NS

IF U

SIN

G E

NG

INEE

RED

, PR

EFAB

RIC

ATED

SLA

BS.

2. A

LLO

W S

UFF

ICIE

NT

RO

OM

ON

ALL

SID

ES O

F TH

E G

ENER

ATO

R F

OR

MAI

NTE

NAN

CE

AN

D S

ERVI

CIN

G. T

HIS

UN

IT M

UST

BE

INST

ALLE

D IN

AC

CO

RD

ANC

E W

ITH

CU

RR

ENT

APP

LIC

ABLE

NFP

A 37

AN

D N

FPA

70 S

TAN

DAR

DS

AS W

ELL

AS A

NY

OTH

ER F

EDER

AL,

STA

TE, A

ND

LO

CAL

CO

DES

.3.

CO

NTR

OL

PAN

EL /

CIR

CU

IT B

REA

KER

INFO

RM

ATIO

N:

- S

EE S

PEC

IFIC

ATIO

N S

HEE

T O

R O

WN

ERS

MAN

UAL

- A

CC

ESSI

BLE

THR

OU

GH

CU

STO

MER

AC

CES

S AS

SEM

BLY

DO

OR

ON

REA

R O

F G

ENER

ATO

R.

4. R

EMO

VE T

HE

REA

R E

NC

LOSU

RE

CO

VER

PAN

EL T

O A

CC

ESS

TH

E ST

UB-

UP

AREA

S AS

FO

LLO

WS:

- H

IGH

VO

LTAG

E C

ON

NEC

TIO

N IN

CLU

DIN

G A

C L

OAD

LEA

D C

ON

DU

IT C

ON

NEC

TIO

N

NEU

TRAL

CO

NN

ECTI

ON

, BAT

TER

Y C

HAR

GER

120

VO

LT A

C (0

.5 A

MP

MAX

) CO

NN

ECTI

ON

. -

LO

W V

OLT

AGE

CO

NN

ECTI

ON

INC

LUD

ING

TR

ANSF

ER S

WIT

CH

CO

NTR

OL

WIR

ES.

5. C

ENTE

R O

F G

RAV

ITY

AND

WEI

GH

T M

AY C

HAN

GE

DU

E TO

UN

IT O

PTIO

NS.

6. B

OTT

OM

OF

GEN

ERAT

OR

SET

MU

ST B

E EN

CLO

SED

TO

PR

EVEN

T PE

ST IN

TRU

SIO

N A

ND

REC

IRC

ULA

TIO

N O

F D

ISC

HAR

GE

AIR

AN

D/O

R IM

PRO

PER

CO

OLI

NG

AIR

FLO

W.

7. R

EFER

ENC

E O

WN

ERS

MAN

UAL

FO

R L

IFTI

NG

WAR

NIN

GS.

8. M

OU

NTI

NG

BO

LTS

OR

STU

DS

TO M

OU

NTI

NG

SU

RFA

CE

SHAL

L BE

5/8

-11

GR

ADE

5 (

USE

STA

ND

ARD

SAE

TO

RQ

UE

SPEC

S)9.

MU

ST A

LLO

W F

REE

FLO

W O

F IN

TAKE

AIR

, DIS

CH

ARG

E AI

R A

ND

EXH

AUST

. SEE

SPE

C S

HEE

T FO

R M

INIM

UM

AIR

FLO

W A

ND

MAX

IMU

M R

ESTR

ICTI

ON

REQ

UIR

EMEN

TS.

10. G

ENER

ATO

R M

UST

BE

INST

ALLE

D S

UC

H T

HAT

FR

ESH

CO

OLI

NG

AIR

IS A

VAIL

ABLE

AN

D T

HAT

DIS

CH

ARG

E AI

R F

RO

M R

ADIA

TOR

IS N

OT

REC

IRC

ULA

TED

.11

. EXH

AUST

MU

FFLE

R E

NC

LOSE

D W

ITH

IN G

ENER

ATO

R E

NC

LOSU

RE,

REM

OVE

FR

ON

T PA

NEL

TO

AC

CES

S.

TOP

VIEW

LEFT

SID

E VI

EW

REA

R V

IEW

RIG

HT

SID

E VI

EW

RAD

IATO

R/E

XHAU

STD

ISC

HAR

GE

AIR

(BO

TH S

IDES

)

AIR

INTA

KE(B

OTH

SID

ES)

REF

EREN

CE

OW

NER

S M

ANU

ALFO

R P

ERIO

DIC

REP

LAC

EMEN

TPA

RTS

LIS

T

DIM

ENSI

ON

S: M

M [I

NC

H]

EXH

AUST

MU

FFLE

REN

CLO

SED

WIT

HIN

GEN

ERAT

OR

EN

CLO

SUR

E

RAD

IATO

R/E

XHAU

STD

ISC

HAR

GE

AIR

CU

STO

MER

AC

CES

SAS

SEM

BLY,

CO

NTR

OL

PAN

EL A

CC

ESS

BATT

ERY

CH

ARG

ERLO

CAT

ED W

ITH

INSE

E N

OTE

4

REA

R E

NC

LOSU

RE

CO

VER

PAN

ELSE

E N

OTE

4C

IRC

UIT

BR

EAKE

RSE

E N

OTE

3

VIC

E AC

TIO

N L

ATC

H O

NE

PER

DO

OR

O

NE

LIFT

OFF

DO

OR

PER

SID

E O

F G

ENER

ATO

R

FUEL

LIN

E C

ON

NEC

TIO

N1-

1/4"

NPT

FEM

ALE

TEE

THR

OU

GH

BAS

EFR

AME

OPE

NIN

G

REM

OVE

CO

VER

FOR

AC

CES

S TO

RAD

IATO

R F

ILL

CAP

BATT

ERY

12V

GR

OU

P 27

FN

EGAT

IVE

GR

OU

ND

P/N

G05

8665

installation layout48 kWDrawing #A0000293718-C (1 of 2)

Prot

ecto

r® S

erie

s

Page 7: Protector o t c e t o Series · Internal Fault Protection ... Wi-Fi LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP

7of 7

®

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com©2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part Number A0000373704 Rev B 12/30/19

®

Drawing #A0000293718-C (2 of 2)

Prot

ecto

r® S

erie

s

installation layout48 kW

46.6

[1.8

3]

1867

.3[7

3.5]

251.

6[9

.9]

850

[33.

5]

2119

[83.

4]

786

[30.

9] 51 [2.0

]9 [.4

]16

2[6

.4]

STU

B-U

PAR

EA

162

[6.4

]ST

UB-

UP

AREA

100

[3.9

4]19

19[7

5.5]

MO

UN

TIN

G S

LOT

CEN

TER

S83

8.1

[33.

00]

MO

UN

TIN

G S

LOT

CEN

TER

S

*NO

TE:

STU

B-U

P AR

EA F

OR

HIG

H A

ND

LO

WVO

LTAG

E C

ON

NEC

TIO

NS,

CIR

CU

IT B

REA

KER

,N

EUTR

AL A

ND

CU

STO

MER

CO

NN

ECTI

ON

OPE

NIN

G.

DIM

ENSI

ON

S: M

M [I

NC

H]

LEFT

SID

E VI

EW

13.5

X 2

9.5

[.53]

[

1.2]

MO

UN

TIN

G S

LOTS

4X

HIG

H A

ND

LO

WVO

LTAG

EST

UB-

UP

AREA

TOP

VIEW

REM

OVA

BLE

STU

B-U

P C

OVE

R

REA

R V

IEW


Recommended