12/1/2017 PUMP INSTALLATION PRESENTATION 1 PUMP INSTALLATION Tim Sullivan, P.E.
Transcript
Page 1: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 1

PUMP INSTALLATION

Tim Sullivan, P.E.

Page 2: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

PRESENTATION AGENDA

≡ Prior to installation

≡ Pipe, Fittings, and Valves

≡ Nozzle Strain, Couplings and Offsets

≡ Seals, Packing and Gauges

≡ Pump Pedestal, Anchors and Grout

12/1/2017 PUMP INSTALLATION PRESENTATION 2

Page 3: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 3

Questions? Fire Away

Pump Orientation

Page 4: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

PRIOR TO INSTALLATION:

≡Get customized (annotated) O&M

manuals

≡Off loading

≡Maintenance (storage and prior

to installation

≡Installation

≡Maintain (rotate shaft) while in

storage

12/1/2017 PUMP INSTALLATION PRESENTATION 4

Page 5: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Suction Pipe

≡Important hydraulically (for centrifugal pumps)

≡Straight runs – 4-6 diameters

≡Example: 6” pipe 2 ft. to 3 ft. straight run min.

≡Reducer

≡Eccentric

≡Connect to the pump

12/1/2017 PUMP INSTALLATION PRESENTATION 5

Page 6: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Discharge Pipe

≡ Not as important hydraulically (Get it out of the way)

≡ Vertical – use Base elbows (watch out for check valves)

≡ Horizontal – go back to suction header

≡ Reducer

≡ Conncet to pump

≡ Concentric reducer

≡ Provide air vents stop cocks

≡ Consider 45 Degree Fittings, Wyes and Laterals

12/1/2017 PUMP INSTALLATION PRESENTATION 6

Page 7: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 7

Page 8: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 8

Page 9: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.
Page 10: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Couplings

Use to help disassemble pipe – pump

Install btw isolation valve and pump

Dresser, Victaulic (grooved) Disassembly style coupling

Thrust restrained on discharge (always, sometimes on suction

Generally best to use on suction side

Not suitable for offsets

Use mitered fitting

12/1/2017 PUMP INSTALLATION PRESENTATION 10

Page 11: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Couplings

12/1/2017 PUMP INSTALLATION PRESENTATION 11

Page 12: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 12

Page 13: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 13

Page 14: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Nozzle Strain, Pipe Alignment, Couplings and

Offsets

≡ Nozzle strain

≡ Couplings (Dresser style)

≡ Excellent to align in X axis

≡ Only 4 degrees in off-set direction

≡ Mechanical vs flanged fittings – Rotate

≡ Flex Connectors

≡ Bevel and filler flanges

≡ Fabricated off-set pipe (best for significant off-sets)

12/1/2017 PUMP INSTALLATION PRESENTATION 14

Page 15: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Isolation Valves

≡Generally both suction and discharge

sides of pumps

≡Suction: Install upstream of straight

diameters

≡Discharge: Install downstream of check

valve

≡Type – very dependent on the service

12/1/2017 PUMP INSTALLATION PRESENTATION 15

Page 16: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Check Valves

≡Always on the pump discharge

≡Install check valve after reducer

≡Be careful of check valves in the vertical

≡Foot Valves – generally not a good idea

12/1/2017 PUMP INSTALLATION PRESENTATION 16

Page 17: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 17

Reducers – Connect at the Pump

Page 18: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 18

Page 19: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Energy Considerations

≡ Laterals, Wyes, 45’s and Long Radius 90’s’

≡ Watch out for checks valves – WIDE variety of Headloss

12/1/2017 PUMP INSTALLATION PRESENTATION 19

Page 20: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

≡ Laterals and 45’s vs 90’

≡ Watch checks valves

12/1/2017 PUMP INSTALLATION PRESENTATION 20

Page 21: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 21

Page 22: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 22

Page 23: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Eccentric on Suction Side

12/1/2017 PUMP INSTALLATION PRESENTATION 23

Page 24: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 24

Page 25: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.
Page 26: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.
Page 27: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Mag meters

≡ 3 to1 straight pipe diameters, suction to discharge minimum

≡ Ideal 10 to 3 pipe diameters

≡ Example 6” pipe:

≡ 3 x 6 “ = 18” straight pipe suction (min.)

≡ 1 x 6” = 6” strainght discharge pipe (min.)

≡ 60” and 18” ideal

12/1/2017 PUMP INSTALLATION PRESENTATION 27

Page 28: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 28

Page 29: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 29

Page 30: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 30

Page 31: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 31

Page 32: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

SEALS AND PACKING

≡Mechanical seals – MANY styles and materials, consult mfr.

≡Generally silicone-carbide seals work for WW applications, carbon-

ceramic for W applications

≡ Single seal fine with flush-water, double if not available

≡Consider split seals for large diameter shafts

≡ Seal water pressure greater than stuffing box pressure

≡ Packing rings – make sure gland is centered at flushing port

≡Adjust periodically, but don’t overtighten

12/1/2017 PUMP INSTALLATION PRESENTATION 32

Page 33: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

GAUGES AND INSTRUMENTS

≡Gauges

Required start-up, and to assess pump performance / trouble

shoot

Gauge not necessarily required, just fittings

Compound gauges required on suction lift pumps

≡Consider vibration monitoring, amp draw, temperature monitors,

preferable on critical assets and larger ($$$) pumps

≡Get baseline data and compare over time

12/1/2017 PUMP INSTALLATION PRESENTATION 33

Page 34: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Seal Water System

Page 35: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 35

Page 36: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Pipe Installation Directions

≡ To the pump from both sides – not good

≡ To the pump, then away from the pump - best

12/1/2017 PUMP INSTALLATION PRESENTATION 36

Page 37: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Nozzle Strain, Pipe Alignment, Couplings and

Offsets

≡ Nozzle strain

≡ Couplings (Dresser style)

≡ Excellent to align in X axis

≡ Only 4 degrees in off-set direction

≡ Mechanical vs flanged fittings – Rotate

≡ Flex Connectors

≡ Bevel and filler flanges

≡ Fabricated off-set pipe (best for significant off-sets)

12/1/2017 PUMP INSTALLATION PRESENTATION 37

Page 38: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

PUMP BASEPLATE, PEDESTAL,

ANCHORS, AND GROUT

≡System, act in unison

≡Pedestal: anchors pump mass to structural base slab

≡Gap required to adjust and align pump baseplate

≡Grout: fill void between pump baseplate and pedestal

≡Baseplate designed to HI Standard 1.3.8

≡Anchors tie the baseplate, grout and pedestal together

in unison

12/1/2017 PUMP INSTALLATION PRESENTATION 38

Page 39: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Concrete Pedestal

≡ Size 3 – 5 times pump – motor mass

≡ Set 6” + away from pump baseplate edge (all sides)

≡ Bush hammer floor slab

≡ Install Reinforcing steel into floor slab

≡ Apply bonding agent

≡ Pump anchors system:

≡ Locate with template

≡ Secured in pedestal or embedded into floor slab

12/1/2017 PUMP INSTALLATION PRESENTATION 39

Page 40: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Anchor System

≡ Sized by Mfr. (or Engineer) but Owner/Contractor can purchase

≡ J-bolt (new) epoxy anchors (existing)

≡ Anchor, nut, plate, and sleeve

≡ Protect sleeve void (foam insulation) and threads (grease, putty, tape, etc.)

12/1/2017 PUMP INSTALLATION PRESENTATION 40

Page 41: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 41

Page 42: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Pump Base Alignment

≡ Wedges / Shims vs jacking screws

≡ DON’T use double nuts

≡ Front to back first (X), then side to side (Y)

≡ Always remove shims

12/1/2017 PUMP INSTALLATION PRESENTATION 42

Page 43: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 43

Page 44: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 44

Page 45: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 45

Page 46: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Grout Course

≡ Use non-shrink grout or flowable epoxy under baseplate

≡ 1” to 2” thick

≡ Some baseplates are fabricated and entire void needs to be filled (i.e.

chopper pump)

≡ Require air vent

≡ Consult with manufacturer. Grout must harden (~25+ hours) prior to

torqueing

≡ Remove shims / wedges prior to torqueing

≡ Grout must cure (72+ hours) prior to testing

12/1/2017 PUMP INSTALLATION PRESENTATION 46

Page 47: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 47

Page 48: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 48

Page 49: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 49

Page 50: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 50

Page 51: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 51

Page 52: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 52

Page 53: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Check pump/motor alignment (angular alignment)

Eyesight – straight edge & feeler gauges

Mechanical

Displacement -

dial indicators

Page 54: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Check pump/motor alignment (parallel alignment)Laser Optic

Systems

Eyesight – straight edge & feeler gauges

Page 55: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.
Page 56: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 56

Page 57: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 57

Page 58: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 58

Page 59: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 59

Page 60: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

Away from

Electrical Panel

Rubber SS

Electrical

Page 61: PUMP INSTALLATION - mi-wea.org≡1” to 2” thick ≡Some baseplates are fabricated and entire void needs to be filled (i.e. chopper pump) ≡Require air vent ≡Consult with manufacturer.

12/1/2017 PUMP INSTALLATION PRESENTATION 61

Thank you!Tim Sullivan, [email protected]