+ All Categories
Home > Documents > Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB /...

Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB /...

Date post: 30-Jan-2018
Category:
Upload: buidung
View: 216 times
Download: 0 times
Share this document with a friend
54
Pumps n Valves n Systems Pumps and Automation 2011
Transcript
Page 1: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

Pumps n Valves n Systems

Pumps and Automation 2011

Page 2: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

O u r h i g h s t a n d a r d :

C r e a t i n g i n t e l l i g e n t s o l u t i o n s

We have supplied generations of

customers worldwide with pumps, valves,

automation products and services.

A company with that kind of experience

knows that success never stands still.

It flows. And the process that makes

that possible is a running partnership

between developer and user, between

production and practice.

Partners move more together. We

do everything possible to ensure that

our customers always have access to the

ideal product and system solutions. KSB

is a loyal partner. And a strong one:

• Over 130 years’ experience

• Present in more than 100 countries

• More than 14,200 employees

• More than 100 service centres

worldwide

• Approximately 1,900 service specialists

T y p e s e r i e s i n d e x p . 3

P r o d u c t p o r t f o l i o p . 6 - 7

O v e r v i e w o f a p p l i c a t i o n s p . 8 - 1 5

Page 3: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

3

T y p e s e r i e s i n d e x

for pumps and automation

HGB / HGC / HGD 46HGM 46HGM-RO 50HHD 40HK (Nikkiso-KSB) 25HN/BN/TN (Nikkiso-KSB) 25HPH 21HPK 21HPK-L 21HT/BT/TT (Nikkiso-KSB) 25 HX (Nikkiso-KSB) 22HY (Nikkiso-KSB) 23 Hya-Eco K 30Hya-Eco VP 30Hyamaster ISB 52Hyamaster SPS 52Hyamat IK, IV, IVP 31Hyamat K 30Hyamat V 30Hyamat VP 30Hya-Rain / Hya-Rain N 27Hya-Rain Eco 27Hya-Solo E 29Hya-Solo D 29Hya-Solo DV 29hyatronic N 51hyatronic mb 52hyatronic spc 52 Ixo 28 KWP / KWP-Bloc 38

LCC-M 38LCC-R 39LCV 39Level Control 51LHD 40LSA-S 38LSR 39LUV / LUVA 47LUV-Nuclear 48 Magnochem 24Magnochem-Bloc 24Mega 40MDX 40MHD 40Microchem 27mini-Compacta 33MK / MKY 32Movitec PumpDrive 43Movitec VME 28Movitec V / LHS / VS / VC 43Multi Eco 28Multi Eco-Pro 28Multi Eco-Top 28Multitec 43Multitec PumpDrive 43Multitec-RO 50

Omega 44

PSR 48PumpDrive 52Pumping Station CK 800-Eu 33PumpMeter 53

RDLO 44RER 48RHD 46RHM 48RHR / RVR 49Rio 16 Rio C 16Rio Z 16Rio-Eco 17Rio-Eco B 17Rio-Eco Z 17Riotherm 16Riotherm C 16Riotronic Eco 17Riotronic P 17Rotex 32RPH 26RPH-RO 50RSR 48RUV 49RVM 49 S 100D / UPA 100C 42SalTec System 50SalTec DT 50Secochem Ex 24Secochem Ex K 25Sewatec / Sewabloc 37SEZ / SEZT / PHZ / PNZ 47SNW / PNW 47SPY 47

TBC 39

UPA 150C 42UPA 200, 200B, 250C 42UPA 300, 350 42UPA Control 51UPZ, BSX-BSF 42

Vitachrom 44Vitacast / Vitacast E 44Vitalobe 45Vitaprime 45Vitastage 45 VN (Nikkiso-KSB) 25

WBC 38WKT / WKTA / WKTB 47

YNK / KRHA 46

ZW 41

Amacan K 36Amacan P 36Amacan S 36Amacontrol 53Ama-Drainer-Box 33Ama-Drainer N 301 – 358 31Ama-Drainer 400 – 500 31Ama-Drainer 80, 100 31Amajet 37Amaline 37Amamix 36Ama-Porter F / S / ICS 32Ama-Porter CK Pumping Station 34Amaprop 37Amarex KRT 35Amarex KRT dry-installed 35Amarex KRT wet/dry-installed 35Amarex N 35Amarex N CK Pumping Station 34API series (Nikkoso-KSB) 26

Cervomatic EDP.2 51CHTA / CHTC / CHTD 45CHTR 46Compacta 33Controlmatic E.2 51CPK-D 23CPKN 23CPKN PumpDrive 23CTN 26

DN (Nikkiso-KSB) 26

Etabloc 19Etabloc Pump Drive 20Etabloc SYT / Etaline SYT 22Etachrom BC 20 Etachrom BC PumpDrive 20Etachrom NC 20 Etachrom NC PumpDrive 20Etaline 18Etaline PumpDrive 18Etaline-R 19Etaline Z 18Etaline Z PumpDrive 18Etamagno SY / SYI / Bloc SY 22Etanorm / Etanorm-R 19Etanorm Pump Drive 19 Etanorm GPV / CPV 21Etanorm SYT / RSY 22Etaprime B / BN 41Etaprime L 41Etaseco / Etaseco-I 24Etaseco RVP 24Evamatic-Box 34Evamatic-Box ICS 34

Filtra N 29FGD 39

Page 4: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

4

O u r s e r v i c e s :

D e p e n d a b i l i t y a t y o u r c a l l

We tailor our services to enable

new ways of individually optimizing

our products. They underscore our far-

reaching sense of customer responsibil-

ity. That commitment starts before any

orders – for example with sound advice

on financing options. And it goes far

beyond product arrival. A dependable

partnership with KSB lasts for years. Our

services to customers include:

• Remote diagnosis

• Revamping

• TPM® (Total Pump Management)

• System engineering

• Advice on life cycle costs

• Financing options

• Teleservice

• Savings potential analysis

Ready where you are. KSB runs

more than 100 service centres around

the world. Some 1,900 highly trained

KSB specialists are on call to inspect

and maintain your equipment. So you

can plan for a future free of unwanted

surprises. And we also provide individual

on-site training sessions. They ensure

that operators can use KSB products and

systems efficiently and profitably, day in,

day out.

Which is how we secure the long-term

value of our customers’ facilities.

Page 5: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

5

O u r v i s i o n :

M o v i n g m o r e , t o g e t h e r

Yesterday: Movement with a

mission.

When KSB started business in 1871, our

pumps got things moving almost over-

night. From the word go, the company

was an enthusiastic pioneer. The motor

of that dynamism was the sense of con-

tributing to new movement in modern

industry.

That is all history now. But KSB still stays

true to its tradition, and continues to

pioneer remarkable technical skills.

Today: Impetus from innovations.

KSB has spent its long history providing

technical innovations that help custom-

ers and partners work more successfully

than ever.

We gear everything we do to the

real demands of everyday operations.

Products, systems, life cycle costs and

our steadily growing range of services all

put customers and their processes first.

This relies on our special concentration

of activities – from development to sales

and marketing.

Tomorrow: Perspectives for

partnerships.

Lively dialogue with customers has been

a KSB speciality for over 130 years.

Mutual respect remains its hallmark.

Our aim is to strengthen this working

partnership still further. The benefits

are mutual, too: we profit from prac-

tical experience that complements our

years of development know-how. And

so our customers profit from innovative

products, systems and services that

match their demands with precision and

perform ance.

Partnership is a value whose products keep their value. So moving more together makes doubly good sense. We look

forward to teaming up.

Page 6: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

6

Automation possibleFactory-automated

Type / Application Type series Page A

Circulator pumps/hot water service pumps, fixed speed

Rio C / Rio / Rio Z / Riotherm C 16 n n

Riotherm 16 n n n

Circulator pumps, variable speed Riotronic P 17 n n

Riotronic Eco 17 n n n

Rio-Eco / Rio-Eco B / Rio-Eco Z 17 n n n

In-line pumps with fixed/variable speed drive

Etaline / Etaline Z 18 n n n

Etaline PumpDrive / Etaline Z PumpDrive 18 n n n n

Etaline-R 19 n n n

Standardized/close-coupled pumps, fixed/variable speed

Etanorm / Etanorm-R 19 n n n n n

Etanorm PumpDrive 19 n n n n n

Etabloc 19 n n n n n

Etabloc PumpDrive 20 n n n n n

Etachrom BC 20 n n n n n

Etachrom BC PumpDrive 20 n n n n n

Etachrom NC 20 n n n n n

Etachrom NC PumpDrive 20 n n n n n

Etanorm GPV / CPV 21 n n n n

Hot water pumps HPK-L / HPK / HPH 21 n n n n

Hot water/thermal oil pumps Etanorm SYT / RSY 22 n n n

Etabloc SYT / Etaline SYT 22 n n n

Thermal oil pumps with magnetic drive / canned motor

Etamagno SY / SYI / Bloc SY 22 n n

HX (Nikkiso-KSB) 22 n

HY (Nikkiso-KSB) 23 n

Standardized chemical pumps CPKN 23 n n n

CPKN PumpDrive 23 n n n

CPK-D 23 n n

Seal-less pumps Magnochem 24 n n n

Magnochem-Bloc 24 n n

Etaseco / Etaseco-I 24 n n n n n

Etaseco RVP 24 n n n n n

Secochem Ex 24 n n n

Secochem Ex K 25 n n n

HN / BN / TN (Nikkiso-KSB) 25 n n

HT / BT / TT (Nikkiso-KSB) 25 n n

HK (Nikkiso-KSB) / VN (Nikkiso-KSB 25 n n

DN (Nikkiso-KSB) 26 n

Process pumps RPH 26 n n n

CTN 26 n

API series (Nikkiso-KSB) 26 n

Centrifugal pump for minimal volume flows Microchem 27 n n

Rainwater harvesting systems Hya-Rain / Hya-Rain N 27 n n n

Hya-Rain Eco 27 n n n

Domestic water supply systems with automatic control unit/swimming pools

Multi Eco 28 n n n n

Multi Eco-Pro 28 n n

Multi Eco-Top 28 n n n n

Movitec VME 28 n n n n

Ixo 28 n n n n

Filtra N 29 n

Pressure booster systems Hya-Solo E / D / DV 29 n n n n

Hya-Eco K / Hya-Eco VP 30 n n n n

Hyamat K / Hyamat V / Hyamat VP 30 n n n n

Hyamat IK, IV, IVP 31 n n n

Drainage pumps/waste water pumps Ama-Drainer N 301, 302, 303, 358 31 n n

Ama-Drainer 400/10 400/35 500/10/11 31 n n n

Ama-Drainer 80, 100 31 n n

Ama-Porter F / S 32 n n

Ama-Porter ICS 32 n n

Rotex 32 n n

MK / MKY 32 n n n

Lifting units/collection tanks Ama-Drainer-Box 33 n n

mini-Compacta 33 n n

Compacta 33 n n n

Pumping Station CK 800-Eu 33 n n

Ama-Porter CK Pumping Station 34 n n

Amarex N CK Pumping Station 34 n n

Evamatic-Box 34 n

Evamatic-Box ICS 34 n n

Submersible motor pumps Amarex N 35 n n n n

Amarex KRT 35 n n n n

Amarex KRT dry-installed 35 n n n n

Amarex KRT wet/dry-installed 35 n n n n

Wat

er T

rans

port

an

d Tr

eatm

ent

Indu

stry

Ener

gy C

onve

rsio

n

Build

ing

Serv

ices

Solid

s Tr

ansp

ort

Auto

mat

ion

Page 7: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

7

Type / Application Type series Page A

Submersible pumps in discharge tubes Amacan K / Amacan P / Amacan S 36 n n

Mixers/agitators/tank cleaning units Amamix, 36 n n

Amaprop, Amajet, Amaline 37 n n

Pumps for solids-laden fluids Sewatec / Sewabloc 37 n n n

KWP / KWP-Bloc 38 n n n n

Slurry pumps WBC 38 n

LSA-S 38 n n n

LCC-M 38 n n n

LCC-R 39 n n n

TBC 39 n

LSR / LCV 39 n

FGD 39 n n n

Mega 40 n

HHD 40 n

MHD 40 n

LHD 40 n

MDX 40 n n

ZW 41 n

Self-priming pumps Etaprime L / Etaprime B / BN 41 n n

Submersible borehole pumps S 100D / UPA 100C 42 n n n n

UPA 150C, 200, 200B, 250C, 300, 350 42 n n n

UPZ, BSX-BSF 42 n n n n

High-pressure pumps, fixed/variable speed Movitec V / LHS / VS / VC 43 n n n n n

Movitec PumpDrive 43 n n n n n

Multitec 43 n n n n n

Multitec PumpDrive 43 n n n n n

Axially split pumps Omega 44 n n n n n

RDLO 44 n n n n n

Hygienic pumps for the food, beverage and pharmaceutical industries

Vitachrom / Vitacast / Vitacast E 44 n n

Vitaprime / Vitastage / Vitalobe 45 n n

Pumps for power station conventional islands

CHTA / CHTC / CHTD 45 n

CHTR 46 n

HGB / HGC / HGD 46 n n

HGM 46 n n

YNK / KRHA 46 n

RHD 46 n

LUV / LUVA 47 n

WKT / WKTA / WKTB 47 n

SEZ / SEZT / PHZ / PNZ 47 n n

SNW / PNW 47 n n

SPY 47 n n n

Pumps for power station nuclear islands RER / RSR / PSR 48 n

LUV-Nuclear / RHM 48 n

RVM / RHR / RVR / RUV 49 n

Pumps and pressure exchangers for seawater desalination by reverse osmosis

SalTec System 50 n n

SalTec DT 50 n n

RPH-RO 50 n

HGM-RO 50 n

Multitec-RO 50 n n

Control units Controlmatic E.2 51 n n

Cervomatic EDP.2 51 n n

LevelControl 51 n n

UPA Control 51 n n

hyatronic N 51 n n n

Speed control PumpDrive 52 n n n

hyatronic spc 52 n n n

hyatronic mb 52 n n n

Hyamaster ISB 52 n n n

Hyamaster SPS 52 n n n

Monitoring and diagnostic systems PumpMeter 53 n n

Amacontrol 53 n n

Automation Page

Automation possibleFactory-automated

Wat

er T

rans

port

an

d Tr

eatm

ent

Indu

stry

Ener

gy C

onve

rsio

n

Build

ing

Serv

ices

Solid

s Tr

ansp

ort

Auto

mat

ion

Page 8: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

8

Activated sludgeAggressive liquids

Brackish waterBrine

Cleaning agentsCondensate

CoolantCooling water

Corrosive liquidsDestillate

Digested sludgeDipping paintsDrinking water

Explosive liquidsFeed water

Fire-fighting waterFlammable liquids

FuelsGas-containing liquids

Harmful liquidsHeating water

Highly aggressive liquidsHigh-temperature hot water

Hot waterHygienic liquids

Industrial service waterInorganic liquids

Liquefied gasLubricants

OilsOrganic liquids

Polymerizing liquidsRaw sludge

River, lake and ground waterSeawater

Service waterSewage with faeces

Sewage without faecesSlurries

Slurries (ore, sand, gravel, ash)Solvents

Swimming-pool waterThermal oil

Toxic liquidsValuable liquidsVolatile liquids

Wash waterWaste water

F l u i d sP

um

ps

C

ircul

ator

pum

ps /

hot w

ater

ser

vice

pum

ps, fi

xed

spee

d

Rio

C

Ri

o / R

io Z

Riot

herm

C

Ri

othe

rm

Circ

ulat

or p

umps

, var

iabl

e sp

eed

Riot

roni

c P

/ Rio

tron

ic E

co

Ri

o-Ec

o

Ri

o-Ec

o B

Rio-

Eco

Z

In-li

ne p

umps

with

fixe

d / v

aria

ble

spee

d dr

ive

Etal

ine

/ Eta

line

Z

Et

alin

e Pu

mpD

rive

/ Eta

line

Z Pu

mpD

rive

Etal

ine-

R

Stan

dard

ized

/ cl

ose-

coup

led

pum

ps, fi

xed

/ var

iabl

e sp

eed

Etan

orm

/ Et

anor

m-R

/ Et

anor

m P

umpD

rive

Etab

loc

/ Eta

bloc

Pum

pDriv

e

Et

achr

om B

C / E

tach

rom

BC

Pum

pDriv

e

Et

achr

om N

C / E

tach

rom

NC

Pum

pDriv

e

Et

anor

m G

PV /

CPV

Ho

t wat

er p

umps

HPK-

L

HP

H

HP

K

Hot w

ater

/ th

erm

al o

il pu

mps

Et

anor

m S

YT /

RSY

Etab

loc

SYT

/ Eta

line

SYT

Th

erm

al o

il pu

mps

with

mag

netic

driv

e / c

anne

d m

otor

Etam

agno

SY

/ SYI

/ Bl

oc S

Y

HX

(Nik

kiso

-KSB

)

HY

(Nik

kiso

-KSB

)

Stan

dard

ized

che

mic

al p

umps

CPKN

/ CP

KN P

umpD

rive

CPK-

D

Seal

-less

pum

ps

M

agno

chem

/ M

agno

chem

-Blo

c

Et

asec

o / E

tase

co-I

Etas

eco

RVP

Seco

chem

Ex

Seco

chem

Ex

K

HN

/ BN

/ TN

(Nik

kiso

-KSB

)

HT

/ B

T / T

T (N

ikki

so-K

SB)

HK (N

ikki

so-K

SB)

VN (N

ikki

so-K

SB)

DN (N

ikki

so-K

SB)

Pr

oces

s pu

mps

RPH

CTN

API s

erie

s (N

ikki

so-K

SB)

Ce

ntrif

ugal

pum

p fo

r min

imal

vol

ume

flow

s

M

icro

chem

Ra

inw

ater

har

vest

ing

syst

ems

Hya-

Rain

/ Hy

a-Ra

in N

Hya-

Rain

Eco

Do

mes

tic w

ater

sup

ply

syst

ems

with

aut

omat

ic c

ontr

ol u

nit /

sw

imm

ing

pool

s

M

ulti

Eco

/ Mul

ti Ec

o-Pr

o

M

ulti

Eco-

Top

Mov

itec V

ME

Ixo

Filtr

a N

Pr

essu

re b

oost

er s

yste

ms

Hya-

Solo

E

Hya-

Solo

D /

DV

Hy

a-Ec

o K

/ Hya

-Eco

VP

Hyam

at K

Hyam

at V

Hyam

at V

P

Hy

amat

IK, I

V, IV

P

Drai

nage

pum

ps /

was

te w

ater

pum

ps

Am

a-Dr

aine

r N 3

01, 3

02, 3

03, 3

58

Am

a-Dr

aine

r 400

/10

400/

35 5

00/1

0/11

Ama-

Drai

ner 8

0, 1

00

Am

a-Po

rter

F /

S / I

CS

Ro

tex

MK

/ MKY

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Page 9: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

9

Activated sludgeAggressive liquidsBrackish waterBrineCleaning agentsCondensateCoolantCooling waterCorrosive liquidsDestillateDigested sludgeDipping paintsDrinking waterExplosive liquidsFeed waterFire-fighting waterFlammable liquidsFuelsGas-containing liquidsHarmful liquidsHeating waterHighly aggressive liquidsHigh-temperature hot waterHot waterHygienic liquidsIndustrial service waterInorganic liquidsLiquefied gasLubricantsOilsOrganic liquidsPolymerizing liquidsRaw sludgeRiver, lake and ground waterSeawaterService waterSewage with faecesSewage without faecesSlurriesSlurries (ore, sand, gravel, ash)SolventsSwimming-pool waterThermal oilToxic liquidsValuable liquidsVolatile liquidsWash waterWaste water

C

ircul

ator

pum

ps /

hot w

ater

ser

vice

pum

ps, fi

xed

spee

d

Rio

C

Ri

o / R

io Z

Riot

herm

C

Ri

othe

rm

Circ

ulat

or p

umps

, var

iabl

e sp

eed

Riot

roni

c P

/ Rio

tron

ic E

co

Ri

o-Ec

o

Ri

o-Ec

o B

Rio-

Eco

Z

In-li

ne p

umps

with

fixe

d / v

aria

ble

spee

d dr

ive

Etal

ine

/ Eta

line

Z

Et

alin

e Pu

mpD

rive

/ Eta

line

Z Pu

mpD

rive

Etal

ine-

R

Stan

dard

ized

/ cl

ose-

coup

led

pum

ps, fi

xed

/ var

iabl

e sp

eed

Etan

orm

/ Et

anor

m-R

/ Et

anor

m P

umpD

rive

Etab

loc

/ Eta

bloc

Pum

pDriv

e

Et

achr

om B

C / E

tach

rom

BC

Pum

pDriv

e

Et

achr

om N

C / E

tach

rom

NC

Pum

pDriv

e

Et

anor

m G

PV /

CPV

Ho

t wat

er p

umps

HPK-

L

HP

H

HP

K

Hot w

ater

/ th

erm

al o

il pu

mps

Et

anor

m S

YT /

RSY

Etab

loc

SYT

/ Eta

line

SYT

Th

erm

al o

il pu

mps

with

mag

netic

driv

e / c

anne

d m

otor

Etam

agno

SY

/ SYI

/ Bl

oc S

Y

HX

(Nik

kiso

-KSB

)

HY

(Nik

kiso

-KSB

)

Stan

dard

ized

che

mic

al p

umps

CPKN

/ CP

KN P

umpD

rive

CPK-

D

Seal

-less

pum

ps

M

agno

chem

/ M

agno

chem

-Blo

c

Et

asec

o / E

tase

co-I

Etas

eco

RVP

Seco

chem

Ex

Seco

chem

Ex

K

HN

/ BN

/ TN

(Nik

kiso

-KSB

)

HT

/ B

T / T

T (N

ikki

so-K

SB)

HK (N

ikki

so-K

SB)

VN (N

ikki

so-K

SB)

DN (N

ikki

so-K

SB)

Pr

oces

s pu

mps

RPH

CTN

API s

erie

s (N

ikki

so-K

SB)

Ce

ntrif

ugal

pum

p fo

r min

imal

vol

ume

flow

s

M

icro

chem

Ra

inw

ater

har

vest

ing

syst

ems

Hya-

Rain

/ Hy

a-Ra

in N

Hya-

Rain

Eco

Do

mes

tic w

ater

sup

ply

syst

ems

with

aut

omat

ic c

ontr

ol u

nit /

sw

imm

ing

pool

s

M

ulti

Eco

/ Mul

ti Ec

o-Pr

o

M

ulti

Eco-

Top

Mov

itec V

ME

Ixo

Filtr

a N

Pr

essu

re b

oost

er s

yste

ms

Hya-

Solo

E

Hya-

Solo

D /

DV

Hy

a-Ec

o K

/ Hya

-Eco

VP

Hyam

at K

Hyam

at V

Hyam

at V

P

Hy

amat

IK, I

V, IV

P

Drai

nage

pum

ps /

was

te w

ater

pum

ps

Am

a-Dr

aine

r N 3

01, 3

02, 3

03, 3

58

Am

a-Dr

aine

r 400

/10

400/

35 5

00/1

0/11

Ama-

Drai

ner 8

0, 1

00

Am

a-Po

rter

F /

S / I

CS

Ro

tex

MK

/ MKY

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n

n

nn

n

n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n

n

n

Page 10: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

10

Activated sludgeAggressive liquids

Brackish waterBrine

Cleaning agentsCondensate

CoolantCooling water

Corrosive liquidsDestillate

Digested sludgeDipping paintsDrinking water

Explosive liquidsFeed water

Fire-fighting waterFlammable liquids

FuelsGas-containing liquids

Harmful liquidsHeating water

Highly aggressive liquidsHigh-temperature hot water

Hot waterHygienic liquids

Industrial service waterInorganic liquids

Liquefied gasLubricants

OilsOrganic liquids

Polymerizing liquidsRaw sludge

River, lake and ground waterSeawater

Service waterSewage with faeces

Sewage without faecesSlurries

Slurries (ore, sand, gravel, ash)Solvents

Swimming-pool waterThermal oil

Toxic liquidsValuable liquidsVolatile liquids

Wash waterWaste water

F l u i d s P

um

ps

Li

fting

uni

ts /

colle

ctin

g ta

nks

Ama-

Drai

ner-B

ox

m

ini-C

ompa

cta

Com

pact

a

Pu

mpi

ng S

tatio

n CK

800

-Eu

Ama-

Port

er C

K Pu

mpi

ng S

tatio

n

Am

arex

N C

K Pu

mpi

ng S

tatio

n

Ev

amat

ic-B

ox /

Evam

atic

-Box

ICS

Su

bmer

sibl

e m

otor

pum

ps

Am

arex

N

Am

arex

KRT

Amar

ex K

RT d

ry-in

stal

led

Amar

ex K

RT w

et/d

ry-in

stal

led

Su

bmer

sibl

e pu

mps

in d

isch

arge

tube

s

Am

acan

K

Am

acan

P

Am

acan

S

Mix

ers

/ agi

tato

rs /

tank

cle

anin

g un

its

Am

amix

Amap

rop

Amaj

et

Am

alin

e

Pum

ps fo

r sol

ids-

lade

n flu

ids

Sew

atec

/ Se

wab

loc

KWP

/ KW

P-Bl

oc

Slur

ry p

umps

WBC

LSA-

S

LC

C-M

/ LC

C-R

TBC

LSR

LCV

FGD

Meg

a

HH

D

M

HD

LH

D

M

DX

ZW

Se

lf-pr

imin

g pu

mps

Etap

rime

L

Et

aprim

e B

/ BN

Su

bmer

sibl

e bo

reho

le p

umps

S

100D

/ U

PA 1

00C

UPA

150

C

U

PA 2

00, 2

00B,

250

C

U

PA 3

00, 3

50

U

PZ, B

SX-B

SF

High

-pre

ssur

e pu

mps

, fixe

d / v

aria

ble

spee

d

M

ovite

c V /

LHS

/ VS

/ VC

Mov

itec

Pum

pDriv

e

M

ultit

ec /

Mul

titec

Pum

pDriv

e

Axia

lly s

plit

pum

ps

O

meg

a

RD

LO

Hygi

enic

pum

ps fo

r the

food

, bev

erag

e an

d ph

arm

aceu

tical

indu

strie

s

Vi

tach

rom

/ Vi

taca

st /

Vita

cast

E

Vi

tapr

ime

/ Vita

stag

e / V

italo

be

Pum

ps fo

r pow

er s

tatio

n co

nven

tiona

l isl

ands

CH

TA /

CHTC

/ CH

TD

CH

TR

HG

B / H

GC

/ HG

D

HG

M

YN

K / K

RHA

RHD

LUV

/ LU

VA

WKT

/ W

KTA

/ WKT

B

SE

Z / S

EZT

/ PHZ

/ PN

Z

SN

W /

PNW

SPY

Pu

mps

for p

ower

sta

tion

nucl

ear i

slan

ds

RE

R / R

SR /

PSR

LUV

nucl

ear

RHM

RVM

RHR

/ RVR

RUV

Pu

mps

for s

eaw

ater

des

alin

atio

n by

reve

rse

osm

osis

RP

H-RO

HGM

-RO

Mul

titec

-RO

M

onito

ring

and

diag

nost

ic s

yste

ms

Pum

pMet

er

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n

Page 11: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

11

Activated sludgeAggressive liquidsBrackish waterBrineCleaning agentsCondensateCoolantCooling waterCorrosive liquidsDestillateDigested sludgeDipping paintsDrinking waterExplosive liquidsFeed waterFire-fighting waterFlammable liquidsFuelsGas-containing liquidsHarmful liquidsHeating waterHighly aggressive liquidsHigh-temperature hot waterHot waterHygienic liquidsIndustrial service waterInorganic liquidsLiquefied gasLubricantsOilsOrganic liquidsPolymerizing liquidsRaw sludgeRiver, lake and ground waterSeawaterService waterSewage with faecesSewage without faecesSlurriesSlurries (ore, sand, gravel, ash)SolventsSwimming-pool waterThermal oilToxic liquidsValuable liquidsVolatile liquidsWash waterWaste water

Li

fting

uni

ts /

colle

ctin

g ta

nks

Ama-

Drai

ner-B

ox

m

ini-C

ompa

cta

Com

pact

a

Pu

mpi

ng S

tatio

n CK

800

-Eu

Ama-

Port

er C

K Pu

mpi

ng S

tatio

n

Am

arex

N C

K Pu

mpi

ng S

tatio

n

Ev

amat

ic-B

ox /

Evam

atic

-Box

ICS

Su

bmer

sibl

e m

otor

pum

ps

Am

arex

N

Am

arex

KRT

Amar

ex K

RT d

ry-in

stal

led

Amar

ex K

RT w

et/d

ry-in

stal

led

Su

bmer

sibl

e pu

mps

in d

isch

arge

tube

s

Am

acan

K

Am

acan

P

Am

acan

S

Mix

ers

/ agi

tato

rs /

tank

cle

anin

g un

its

Am

amix

Amap

rop

Amaj

et

Am

alin

e

Pum

ps fo

r sol

ids-

lade

n flu

ids

Sew

atec

/ Se

wab

loc

KWP

/ KW

P-Bl

oc

Slur

ry p

umps

WBC

LSA-

S

LC

C-M

/ LC

C-R

TBC

LSR

LCV

FGD

Meg

a

HH

D

M

HD

LH

D

M

DX

ZW

Se

lf-pr

imin

g pu

mps

Etap

rime

L

Et

aprim

e B

/ BN

Su

bmer

sibl

e bo

reho

le p

umps

S

100D

/ U

PA 1

00C

UPA

150

C

U

PA 2

00, 2

00B,

250

C

U

PA 3

00, 3

50

U

PZ, B

SX-B

SF

High

-pre

ssur

e pu

mps

, fixe

d / v

aria

ble

spee

d

M

ovite

c V /

LHS

/ VS

/ VC

Mov

itec

Pum

pDriv

e

M

ultit

ec /

Mul

titec

Pum

pDriv

e

Axia

lly s

plit

pum

ps

O

meg

a

RD

LO

Hygi

enic

pum

ps fo

r the

food

, bev

erag

e an

d ph

arm

aceu

tical

indu

strie

s

Vi

tach

rom

/ Vi

taca

st /

Vita

cast

E

Vi

tapr

ime

/ Vita

stag

e / V

italo

be

Pum

ps fo

r pow

er s

tatio

n co

nven

tiona

l isl

ands

CH

TA /

CHTC

/ CH

TD

CH

TR

HG

B / H

GC

/ HG

D

HG

M

YN

K / K

RHA

RHD

LUV

/ LU

VA

WKT

/ W

KTA

/ WKT

B

SE

Z / S

EZT

/ PHZ

/ PN

Z

SN

W /

PNW

SPY

Pu

mps

for p

ower

sta

tion

nucl

ear i

slan

ds

RE

R / R

SR /

PSR

LUV

nucl

ear

RHM

RVM

RHR

/ RVR

RUV

Pu

mps

for s

eaw

ater

des

alin

atio

n by

reve

rse

osm

osis

RP

H-RO

HGM

-RO

Mul

titec

-RO

M

onito

ring

and

diag

nost

ic s

yste

ms

Pum

pMet

er

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Page 12: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

12

Air-conditioning systemsAquaculture

Boiler circulationBoiler feed applications

Chemical industryCleaning of stormwater tanks / storage sewers

Condensate transportCooling circuitsDescaling units

DewateringDisposal

District heatingDock facilities

Domestic water supplyDrainage

Drainage of pits, shafts, etc.Dredging

Fire-fighting systemsFlue gas desulphurization

Food and beverages industryFountains

Heat recovery systemsHeavy oil and coal upgrading

HomogenizationHot water heating systemsHydraulic solids transport

Industrial recirculation systemsIrrigation

Keeping in suspensionLowering ground water levels

Maintaining ground water levelsMiningMixing

Nuclear power stationsPaint shops

Paper and cellulose industryPetrochemical industry

Pharmaceutical industry Pipelines and tank farms

Pressure boostingProcess engineering

Rainwater harvestingRecirculation

RefineriesSeawater desalination / reverse osmosis

Sewage treatment plantsShipbuilding

Sludge disposalSludge processing

Snow gunsSpray irrigationSugar industry

Swimming poolsThickening

Washing plantsWater extraction

Water supplyWater treatment systems

A p p l i c a t i o n sP

um

ps

C

ircul

ator

pum

ps /

hot w

ater

ser

vice

pum

ps, fi

xed

spee

d

Rio

C

Ri

o / R

io Z

Riot

herm

C

Ri

othe

rm

Circ

ulat

or p

umps

, var

iabl

e sp

eed

Riot

roni

c P

/ Rio

tron

ic E

co

Ri

o-Ec

o

Ri

o-Ec

o B

Rio-

Eco

Z

In-li

ne p

umps

with

fixe

d / v

aria

ble

spee

d dr

ive

Etal

ine

/ Eta

line

Z

Et

alin

e Pu

mpD

rive

/ Eta

line

Z Pu

mpD

rive

Etal

ine-

R

Stan

dard

ized

/ cl

ose-

coup

led

pum

ps, fi

xed

/ var

iabl

e sp

eed

Etan

orm

/ Et

anor

m-R

/ Et

anor

m P

umpD

rive

Etab

loc

/ Eta

bloc

Pum

pDriv

e

Et

achr

om B

C / E

tach

rom

BC

Pum

pDriv

e

Et

achr

om N

C / E

tach

rom

NC

Pum

pDriv

e

Et

anor

m G

PV /

CPV

Ho

t wat

er p

umps

HPK-

L

HP

H

HP

K

Hot w

ater

/ th

erm

al o

il pu

mps

Et

anor

m S

YT /

RSY

Etab

loc

SYT

/ Eta

line

SYT

Th

erm

al o

il pu

mps

with

mag

netic

driv

e / c

anne

d m

otor

Etam

agno

SY

/ SYI

/ Bl

oc S

Y

HX

(Nik

kiso

-KSB

)

HY

(Nik

kiso

-KSB

)

Stan

dard

ized

che

mic

al p

umps

CPKN

/ CP

KN P

umpD

rive

CPK-

D

Se

al-le

ss p

umps

Mag

noch

em /

Mag

noch

em-B

loc

Etas

eco

/ Eta

seco

-I

Et

asec

o RV

P

Se

coch

em E

x

Se

coch

em E

x K

HN /

BN /

TN (N

ikki

so-K

SB)

HT /

BT

/ TT

(Nik

kiso

-KSB

)

HK

(Nik

kiso

-KSB

)

VN

(Nik

kiso

-KSB

)

DN

(Nik

kiso

-KSB

)

Proc

ess

pum

ps

RP

H

CT

N

AP

I ser

ies

(Nik

kiso

-KSB

)

Cent

rifug

al p

ump

for m

inim

al v

olum

e flo

ws

Mic

roch

em

Rain

wat

er h

arve

stin

g sy

stem

s

Hy

a-Ra

in /

Hya-

Rain

N

Hy

a-Ra

in E

co

Dom

estic

wat

er s

uppl

y sy

stem

s w

ith a

utom

atic

con

trol

uni

t / s

wim

min

g po

ols

Mul

ti Ec

o / M

ulti

Eco-

Pro

Mul

ti Ec

o-To

p

M

ovite

c VM

E

Ix

o

Fi

ltra

N

Pres

sure

boo

ster

sys

tem

s

Hy

a-So

lo E

Hy

a-So

lo D

/ DV

Hya-

Eco

K / H

ya-E

co V

P

Hy

amat

K

Hy

amat

V

Hy

amat

VP

Hyam

at IK

, IV,

IVP

Dr

aina

ge p

umps

/ w

aste

wat

er p

umps

Ama-

Drai

ner N

301

, 302

, 303

, 358

Ama-

Drai

ner 4

00/1

0 40

0/35

500

/10/

11

Am

a-Dr

aine

r 80,

100

Ama-

Port

er F

/ S

/ ICS

Rote

x

M

K / M

KY

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Page 13: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

13

Air-conditioning systemsAquacultureBoiler circulationBoiler feed applicationsChemical industryCleaning of stormwater tanks / storage sewersCondensate transportCooling circuitsDescaling unitsDewateringDisposalDistrict heatingDock facilitiesDomestic water supplyDrainageDrainage of pits, shafts, etc.DredgingFire-fighting systemsFlue gas desulphurizationFood and beverages industryFountainsHeat recovery systemsHeavy oil and coal upgradingHomogenizationHot water heating systemsHydraulic solids transportIndustrial recirculation systemsIrrigationKeeping in suspensionLowering ground water levelsMaintaining ground water levelsMiningMixingNuclear power stationsPaint shopsPaper and cellulose industryPetrochemical industryPharmaceutical industryPipelines and tank farmsPressure boostingProcess engineeringRainwater harvestingRecirculationRefineriesSeawater desalination / reverse osmosisSewage treatment plantsShipbuildingSludge disposalSludge processingSnow gunsSpray irrigationSugar industrySwimming poolsThickeningWashing plantsWater extractionWater supplyWater treatment systems

C

ircul

ator

pum

ps /

hot w

ater

ser

vice

pum

ps, fi

xed

spee

d

Rio

C

Ri

o / R

io Z

Riot

herm

C

Ri

othe

rm

Circ

ulat

or p

umps

, var

iabl

e sp

eed

Riot

roni

c P

/ Rio

tron

ic E

co

Ri

o-Ec

o

Ri

o-Ec

o B

Rio-

Eco

Z

In-li

ne p

umps

with

fixe

d / v

aria

ble

spee

d dr

ive

Etal

ine

/ Eta

line

Z

Et

alin

e Pu

mpD

rive

/ Eta

line

Z Pu

mpD

rive

Etal

ine-

R

Stan

dard

ized

/ cl

ose-

coup

led

pum

ps, fi

xed

/ var

iabl

e sp

eed

Etan

orm

/ Et

anor

m-R

/ Et

anor

m P

umpD

rive

Etab

loc

/ Eta

bloc

Pum

pDriv

e

Et

achr

om B

C / E

tach

rom

BC

Pum

pDriv

e

Et

achr

om N

C / E

tach

rom

NC

Pum

pDriv

e

Et

anor

m G

PV /

CPV

Ho

t wat

er p

umps

HPK-

L

HP

H

HP

K

Hot w

ater

/ th

erm

al o

il pu

mps

Et

anor

m S

YT /

RSY

Etab

loc

SYT

/ Eta

line

SYT

Th

erm

al o

il pu

mps

with

mag

netic

driv

e / c

anne

d m

otor

Etam

agno

SY

/ SYI

/ Bl

oc S

Y

HX

(Nik

kiso

-KSB

)

HY

(Nik

kiso

-KSB

)

Stan

dard

ized

che

mic

al p

umps

CPKN

/ CP

KN P

umpD

rive

CPK-

D

Se

al-le

ss p

umps

Mag

noch

em /

Mag

noch

em-B

loc

Etas

eco

/ Eta

seco

-I

Et

asec

o RV

P

Se

coch

em E

x

Se

coch

em E

x K

HN /

BN /

TN (N

ikki

so-K

SB)

HT /

BT

/ TT

(Nik

kiso

-KSB

)

HK

(Nik

kiso

-KSB

)

VN

(Nik

kiso

-KSB

)

DN

(Nik

kiso

-KSB

)

Proc

ess

pum

ps

RP

H

CT

N

AP

I ser

ies

(Nik

kiso

-KSB

)

Cent

rifug

al p

ump

for m

inim

al v

olum

e flo

ws

Mic

roch

em

Rain

wat

er h

arve

stin

g sy

stem

s

Hy

a-Ra

in /

Hya-

Rain

N

Hy

a-Ra

in E

co

Dom

estic

wat

er s

uppl

y sy

stem

s w

ith a

utom

atic

con

trol

uni

t / s

wim

min

g po

ols

Mul

ti Ec

o / M

ulti

Eco-

Pro

Mul

ti Ec

o-To

p

M

ovite

c VM

E

Ix

o

Fi

ltra

N

Pres

sure

boo

ster

sys

tem

s

Hy

a-So

lo E

Hy

a-So

lo D

/ DV

Hya-

Eco

K / H

ya-E

co V

P

Hy

amat

K

Hy

amat

V

Hy

amat

VP

Hyam

at IK

, IV,

IVP

Dr

aina

ge p

umps

/ w

aste

wat

er p

umps

Ama-

Drai

ner N

301

, 302

, 303

, 358

Ama-

Drai

ner 4

00/1

0 40

0/35

500

/10/

11

Am

a-Dr

aine

r 80,

100

Ama-

Port

er F

/ S

/ ICS

Rote

x

M

K / M

KY

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Page 14: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

14

Air-conditioning systemsAquaculture

Boiler circulationBoiler feed applications

Chemical industryCleaning of stormwater tanks / storage sewers

Condensate transportCooling circuitsDescaling units

DewateringDisposal

District heatingDock facilities

Domestic water supplyDrainage

Drainage of pits, shafts, etc.Dredging

Fire-fighting systemsFlue gas desulphurization

Food and beverages industryFountains

Heat recovery systemsHeavy oil and coal upgrading

HomogenizationHot water heating systemsHydraulic solids transport

Industrial recirculation systemsIrrigation

Keeping in suspensionLowering ground water levels

Maintaining ground water levelsMiningMixing

Nuclear power stationsPaint shops

Paper and cellulose industryPetrochemical industry

Pharmaceutical industryPipelines and tank farms

Pressure boostingProcess engineering

Rainwater harvestingRecirculation

RefineriesSeawater desalination / reverse osmosis

Sewage treatment plantsShipbuilding

Sludge disposalSludge processing

Snow gunsSpray irrigationSugar industry

Swimming poolsThickening

Washing plantsWater extraction

Water supplyWater treatment systems

Pu

mp

sA p p l i c a t i o n s

Li

fting

uni

ts /

colle

ctin

g ta

nks

Ama-

Drai

ner-B

ox

m

ini-C

ompa

cta

Com

pact

a

Pu

mpi

ng S

tatio

n CK

800

-Eu

Ama-

Port

er C

K Pu

mpi

ng S

tatio

n

Am

arex

N C

K Pu

mpi

ng S

tatio

n

Ev

amat

ic-B

ox /

Evam

atic

-Box

ICS

Su

bmer

sibl

e m

otor

pum

ps

Am

arex

N

Am

arex

KRT

Amar

ex K

RT d

ry-in

stal

led

Amar

ex K

RT w

et/d

ry-in

stal

led

Su

bmer

sibl

e pu

mps

in d

isch

arge

tube

s

Am

acan

K

Am

acan

P

Am

acan

S

Mix

ers

/ agi

tato

rs /

tank

cle

anin

g un

its

Am

amix

Amap

rop

Amaj

et

Am

alin

e

Pum

ps fo

r sol

ids-

lade

n flu

ids

Sew

atec

/ Se

wab

loc

KWP

/ KW

P-Bl

oc

Slur

ry p

umps

WBC

LSA-

S

LC

C-M

/ LC

C-R

TBC

LSR

LCV

FGD

Meg

a

HH

D

M

HD

LH

D

M

DX

ZW

Se

lf-pr

imin

g pu

mps

Etap

rime

L

Et

aprim

e B

/ BN

Su

bmer

sibl

e bo

reho

le p

umps

S

100D

/ U

PA 1

00C

UPA

150

C

U

PA 2

00, 2

00B,

250

C

U

PA 3

00, 3

50

U

PZ, B

SX-B

SF

High

-pre

ssur

e pu

mps

, fixe

d / v

aria

ble

spee

d

M

ovite

c V /

LHS

/ VS

/ VC

Mov

itec

Pum

pDriv

e

M

ultit

ec /

Mul

titec

Pum

pDriv

e

Axia

lly s

plit

pum

ps

O

meg

a

RD

LO

Hygi

enic

pum

ps fo

r the

food

, bev

erag

e an

d ph

arm

aceu

tical

indu

strie

s

Vi

tach

rom

/ Vi

taca

st /

Vita

cast

E

Vi

tapr

ime

/ Vita

stag

e / V

italo

be

Pum

ps fo

r pow

er s

tatio

n co

nven

tiona

l isl

ands

CH

TA /

CHTC

/ CH

TD

CH

TR

HG

B / H

GC

/ HG

D

HG

M

YN

K / K

RHA

RHD

LUV

/ LU

VA

WKT

/ W

KTA

/ WKT

B

SE

Z / S

EZT

/ PHZ

/ PN

Z

SN

W /

PNW

SPY

Pu

mps

for p

ower

sta

tion

nucl

ear i

slan

ds

RE

R / R

SR /

PSR

LUV

nucl

ear

RHM

RVM

RHR

/ RVR

RUV

Pu

mps

for s

eaw

ater

des

alin

atio

n by

reve

rse

osm

osis

RP

H-RO

HGM

-RO

Mul

titec

-RO

n

n n n n n n n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Page 15: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

15

Air-conditioning systemsAquacultureBoiler circulationBoiler feed applicationsChemical industryCleaning of stormwater tanks / storage sewersCondensate transportCooling circuitsDescaling unitsDewateringDisposalDistrict heatingDock facilitiesDomestic water supplyDrainageDrainage of pits, shafts, etc.DredgingFire-fighting systemsFlue gas desulphurizationFood and beverages industryFountainsHeat recovery systemsHeavy oil and coal upgradingHomogenizationHot water heating systemsHydraulic solids transportIndustrial recirculation systemsIrrigationKeeping in suspensionLowering ground water levelsMaintaining ground water levelsMiningMixingNuclear power stationsPaint shopsPaper and cellulose industryPetrochemical industryPharmaceutical industryPipelines and tank farmsPressure boostingProcess engineeringRainwater harvestingRecirculationRefineriesSeawater desalination / reverse osmosisSewage treatment plantsShipbuildingSludge disposalSludge processingSnow gunsSpray irrigationSugar industrySwimming poolsThickeningWashing plantsWater extractionWater supplyWater treatment systems

Li

fting

uni

ts /

colle

ctin

g ta

nks

Ama-

Drai

ner-B

ox

m

ini-C

ompa

cta

Com

pact

a

Pu

mpi

ng S

tatio

n CK

800

-Eu

Ama-

Port

er C

K Pu

mpi

ng S

tatio

n

Am

arex

N C

K Pu

mpi

ng S

tatio

n

Ev

amat

ic-B

ox /

Evam

atic

-Box

ICS

Su

bmer

sibl

e m

otor

pum

ps

Am

arex

N

Am

arex

KRT

Amar

ex K

RT d

ry-in

stal

led

Amar

ex K

RT w

et/d

ry-in

stal

led

Su

bmer

sibl

e pu

mps

in d

isch

arge

tube

s

Am

acan

K

Am

acan

P

Am

acan

S

Mix

ers

/ agi

tato

rs /

tank

cle

anin

g un

its

Am

amix

Amap

rop

Amaj

et

Am

alin

e

Pum

ps fo

r sol

ids-

lade

n flu

ids

Sew

atec

/ Se

wab

loc

KWP

/ KW

P-Bl

oc

Slur

ry p

umps

WBC

LSA-

S

LC

C-M

/ LC

C-R

TBC

LSR

LCV

FGD

Meg

a

HH

D

M

HD

LH

D

M

DX

ZW

Se

lf-pr

imin

g pu

mps

Etap

rime

L

Et

aprim

e B

/ BN

Su

bmer

sibl

e bo

reho

le p

umps

S

100D

/ U

PA 1

00C

UPA

150

C

U

PA 2

00, 2

00B,

250

C

U

PA 3

00, 3

50

U

PZ, B

SX-B

SF

High

-pre

ssur

e pu

mps

, fixe

d / v

aria

ble

spee

d

M

ovite

c V /

LHS

/ VS

/ VC

Mov

itec

Pum

pDriv

e

M

ultit

ec /

Mul

titec

Pum

pDriv

e

Axia

lly s

plit

pum

ps

O

meg

a

RD

LO

Hygi

enic

pum

ps fo

r the

food

, bev

erag

e an

d ph

arm

aceu

tical

indu

strie

s

Vi

tach

rom

/ Vi

taca

st /

Vita

cast

E

Vi

tapr

ime

/ Vita

stag

e / V

italo

be

Pum

ps fo

r pow

er s

tatio

n co

nven

tiona

l isl

ands

CH

TA /

CHTC

/ CH

TD

CH

TR

HG

B / H

GC

/ HG

D

HG

M

YN

K / K

RHA

RHD

LUV

/ LU

VA

WKT

/ W

KTA

/ WKT

B

SE

Z / S

EZT

/ PHZ

/ PN

Z

SN

W /

PNW

SPY

Pu

mps

for p

ower

sta

tion

nucl

ear i

slan

ds

RE

R / R

SR /

PSR

LUV

nucl

ear

RHM

RVM

RHR

/ RVR

RUV

Pu

mps

for s

eaw

ater

des

alin

atio

n by

reve

rse

osm

osis

RP

H-RO

HGM

-RO

Mul

titec

-RO

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n n

n

n

n

n

n

n n

n n n

n

Page 16: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

16

Design: Maintenance-free, glandless wet rotor pump, screw-ended, with three speed levels.

Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.

Rio C

Rp _______________ 1 -11/4

Q [m3/h] _________ max. 4H [m] __________ max. 5.8p [bar] __________ max. 10T [°C] _______ -10 to +110Data for 50 Hz operation

Reference no. 1120.5-10 also available in 60 HzSwitchgears

Circulator pump with manual speed control

C i r c u l a t o r p u m p s / h o t w a t e r s e r v i c e p u m p s , f i x e d s p e e d

Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with three speed levels.

Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.

Rio

Rp / DN __ 1-11/4 / 40 - 100Q [m3/h] ________ max. 77H [m] ___________ max. 19p [bar] __________ max. 10T [°C] _______ -20 to +130Data for 50 Hz operation

Switchgears

Circulator pump with manual speed control

Reference no. 1115.51-10 also available in 60 Hz

Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with three speed levels.

Applications: Air-conditioning systems, cooling circuits and water supply.

Riotherm C

Rp / DN __ 1/2 -11/4 / 40 - 50Q [m3/h] ________ max. 28H [m] __________ max. 7.5p [bar] __________ max. 10T [°C] _______ -10 to +110Data for 50 Hz operation

Reference no. 1109.5-10 also suitable for 60 Hz operation

Hot water service pump

Design: Screw-ended dry rotor pump with mechanical seal and fixed speed.

Applications: Hot water supply systems, swimming pools, cooling circuits and industrial plants.

Riotherm

Rp _______________ 1-11/4

Q [m3/h] ________ max. 10H [m] ____________ max. 6p [bar] __________ max. 10T [°C] ________ -2 to +110Data for 50 Hz operation

Reference no. 1118.5-10

Hot water service pump

also available in 60 HzSwitchgears

Automation possible

Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with three speed levels; in twin pump design (Rio Z) for standby operation with inte-grated swing check valve or, on option, peak load operation (parallel operation).

Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.

Rio Z

Rp / DN ___ 1-11/4 / 32 - 80Q [m3/h] _______ max. 130H [m] ___________ max. 18p [bar] __________ max. 10T [°C] _______ -20 to +130Data for 50 Hz operation

Switchgears

Circulator pump with manual speed control

Reference no. 1115.51-10 also available in 60 Hz

Switchgears

Page 17: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

17

C i r c u l a t o r p u m p s , v a r i a b l e s p e e d

Design: Maintenance-free wet rotor pump with integrated frequency inverter for continuously variable differential pressure control and IR interface for remote control.

Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.

Rio-Eco

Rp / DN __ 1-11/4 / 32 - 100Q [m3/h] ________ max. 62H [m] ___________ max. 13p [bar] __________ max. 10T [°C] _______ -10 to +110n [min-1] ______ max. 4800

Reference no. 1137.5-10 also suitable for 60 Hz operation

High-efficiency circulator pump with continuously variable differential pressure control

Design: Maintenance-free wet rotor pump with integrated frequency inverter for continuously variable differential pressure control.

Applications: Industrial recirculation systems, air-conditioning systems, heat recovery systems and hot water heating systems.

Riotronic Eco

Rp _______________ 1-11/4

Q [m3/h] _______ max. 2.5H [m] ____________ max. 5p [bar] __________ max. 10T [°C] ______ +15 to +110n [min-1] ______ max. 3500

Reference no. 1112.51-10

High-efficiency circulator pump with continuously variable differential pressure control

BOA-Systronic

BOA-Systronic

Automation possibleFactory-automated

Design: Maintenance-free wet rotor pump with integrated frequency inverter forcontinuously variable differential pressure control.

Applications: Industrial recirculation systems, air-conditioning systems, heat recovery systems and hot water heating systems.

Riotronic P

Rp _______________ 1-11/4

Q [m3/h] _______ max. 4.2H [m] ____________ max. 6p [bar] __________ max. 10T [°C] ________ -2 to +110n [min-1] ______ max. 4230

Reference no. 1112.52-10 also suitable for 60 Hz operation

High-efficiency circulator pump with continuously variable differential pressure control

Design: Maintenance-free wet rotor pump with integrated frequency inverter for continuously variable differential pressure control and IR interface for remote control.

Applications: Air-conditioning systems, cooling circuits and water supply

Rio-Eco B

Rp / DN ___ 1-11/4 / 40 - 65Q [m3/h] ________ max. 38H [m] ___________ max. 10p [bar] __________ max. 10T [°C] ________ -10 to +80n [min-1] ______ max. 4800

Reference no. 1137.5-10 also suitable for 60 Hz operation

High-efficiency circulator pump with continuously variable differential pressure control

BOA-Systronic

Design: Maintenance-free wet rotor pump in twin pump design, with integrated frequency inverter for continuously variable differential pressure control and IR interface for remote control. Optional pump assignment to main or stand-by duty, with automatic changeover in the event of a fault, timer-controlled pump change-over or parallel operation; peak load pump started or stopped as required for optimum efficiency.

Applications: Industrial recirculation systems, air-conditioning systems, cooling circuits, heat recovery systems and hot water heating systems.

Rio-Eco Z

DN _____________ 32 - 80Q [m3/h] _______ max. 108H [m] ___________ max. 13p [bar] __________ max. 10T [°C] _______ -10 to +110n [min-1] ______ max. 4800

Reference no. 1137.51-10 also suitable for 60 Hz operation

High-efficiency circulator pump with continuously variable differential pressure control

BOA-Systronic

Page 18: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

18

I n - l i n e p u m p s w i t h f i x e d / v a r i a b l e s p e e d d r i v e

Design: Close-coupled, in-line circulator pump with volute casing and standardized motor.

Applications: Hot water heating systems, cooling circuits, air-conditioning, water and service water supply systems, industrial recirculation systems.

Etaline

DN _____________ 32 - 200Q [m3/h] _______ max. 700H [m] ___________ max. 95p [bar] __________ max. 16T [°C] _______ -30 to +140Data for 50 Hz operation

Reference no. 1146.51-10 also available in 60 HzPumpMeter · Hyamaster · LevelControl · Switchgears

In-line pump

Design: Close-coupled, in-line twin circulator pump, pump shaft and motor shaft are rigidly coupled.

Applications: Hot water heating systems, cooling circuits, air-conditioning systems, water and service water supply systems, industrial recirculation systems.

Etaline Z

DN _____________ 32 - 200Q [m3/h] ______ max. 1120H [m] ___________ max. 77p [bar] __________ max. 16T [°C] _______ -30 to +140Data for 50 Hz operation

Reference no. 1148.5-10 also available in 60 HzPumpMeter · Hyamaster · LevelControl · Switchgears

In-line twin pump

Design: Close-coupled in-line circulator pump with motor-mounted variable speed system; pump shaft and motor shaft are rigidly coupled.

Applications: Hot water heating systems, cooling circuits, air-conditioning systems, water and service water supply systems, industrial recirculation systems.

DN _____________ 32 - 200Q [m3/h] _______ max. 788H [m] __________ max. 100p [bar] __________ max. 16T [°C] _______ -10 to +110n [min-1] ______ max. 4200

Reference no. 1149.52-10 also suitable for 60 Hz operation

In-line pump with motor-mounted variable speed systemEtaline PumpDrive

PumpMeter · BOA-Systronic

Design: Close-coupled in-line circulator pump, in twin pump design with motor-mounted variable speed system; pump shaft and motor shaft are rigidly coupled. Double pump control modules (accessories) enable redundant operation of Etaline Z without a higher-level controller.

Applications: Hot water heating systems, cooling circuits, air-conditioning systems, water and service water supply systems, industrial recirculation systems.

DN _____________ 32 - 200Q [m3/h] _______ max. 990H [m] ___________ max. 76p [bar] __________ max. 16T [°C] _______ -10 to +110n [[min-1] ______ max. 4200

Reference no. 1154.51-10 also suitable for 60 Hz operation

In-line pump with motor-mounted variable speed systemEtaline Z PumpDrive

PumpMeter · BOA-Systronic

Automation possibleFactory-automated

Page 19: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

19Automation possibleFactory-automated

I n - l i n e p u m p s w i t h f i x e d / v a r i a b l e s p e e d d r i v e

Design: Vertical close-coupled, in-line circulator pump with volute casing and standardized motor.

Applications: Hot water heating systems, cooling circuits, air-conditioning, water and service water supply systems, industrial recirculation systems.

Etaline-R

DN ___________ 150 - 350Q [m3/h] ______ max. 1900H [m] ___________ max. 93p [bar] __________ max. 25T [°C] _______ -30 to +140Data for 50 Hz operation

Reference no. 1146.51-10 also available in 60 HzPumpMeter · PumpDrive · Hyamaster · Switchgears

In-line pump

S t a n d a r d i z e d / c l o s e - c o u p l e d p u m p s , f i x e d / v a r i a b l e s p e e d

Design: Horizontal, long-coupled, single-stage volute casing pump (pump size 125 - 500 with two stages) with ratings and main dimensions to EN 733, in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings. ATEX-compliant version available.

Applications: Spray irrigation, irrigation, drainage, district heating, water supplysystems, heating and air-conditioning systems, condensate transport, swimmingpools, fire-fighting systems, handling of hot water, cooling water, fire-fighting water, oil, brine, drinking water, brackish water, service water, etc.

Etanorm / Etanorm-R

DN _____________ 32 - 300Q [m3/h] ______ max. 1900H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +140Data for 50 Hz operation

Reference no. 1211.5-10 also available in 60 HzPumpMeter • Hyamaster

Standardized pump

Design: Horizontal, long-coupled, single-stage volute casing pump in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings and motor-mounted variable speed system.

Applications: Spray irrigation, irrigation, drainage, district heating, water supply systems, heating and air-conditioning systems, condensate transport, swimming pools, fire-fighting systems, handling of hot water, cooling water, fire-fighting water, oil, brine, drinking water, brackish water, service water, etc.

Etanorm PumpDrive

DN _____________ 32 - 150Q [m3/h] _______ max. 800H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +140n [min-1] ______ max. 4200

Reference no. 1211.5-10 + 4070.5-10

Standardized pump with motor-mounted variable speed system

Design: Close-coupled, single-stage volute casing pump, ratings to EN 733, withreplaceable shaft sleeve and casing wear rings. ATEX-compliant version available.

Applications: Spray irrigation, irrigation, drainage and water supply systems, heating and air-conditioning systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, seawater, oil, brine, drinking water, cleaning agents, brackish water, service water, etc.

Etabloc

DN _____________ 25 - 150Q [m3/h] _______ max. 660H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +140Data for 50 Hz operation

Reference no. 1167.5-10 also available in 60 HzPumpMeter • Hyamaster

Close-coupled pump

PumpMeter

Page 20: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

20 Automation possibleFactory-automated

Design: Close-coupled, single-stage volute casing pump, ratings to EN 733, withreplaceable shaft sleeve and casing wear rings and motor-mounted variable speed system.

Applications: Spray irrigation, irrigation, drainage and water supply systems, heat-ing and air-conditioning systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, seawater, oil, brine, drinking water, cleaning agents, brackish water, service water, etc.

Etabloc PumpDrive

DN _____________ 25 - 150Q [m3/h] _______ max. 800H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +110n [min-1] ______ max. 4200

Reference no. 1167.5-10 + 4070.5-10

Close-coupled pump with motor-mounted variable speed system

Design: Close-coupled, horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings. ATEX-compliant version available.

Applications: Spray irrigation, irrigation, drainage and water supply systems, heating and air-conditioning systems, fire-fighting systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, oil, drinking water, cleaning agents, service water.

Etachrom BC

DN ______________ 25 - 80Q [m3/h] _______ max. 260H [m] __________ max. 108p [bar] __________ max. 12T [°C] ________ max. +110Data for 50 Hz operation

Reference no. 1213.5-10 also available in 60 HzPumpMeter · Hyamaster

Close-coupled chrome steel pump

S t a n d a r d i z e d / c l o s e - c o u p l e d p u m p s , f i x e d / v a r i a b l e s p e e d

PumpMeter

Design: Close-coupled, horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings and motor-mounted variable speed system.

Applications: Spray irrigation, irrigation, drainage and water supply systems, heating and air-conditioning systems, fire-fighting systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, oil, drinking water, cleaning agents, service water.

Etachrom BC PumpDrive

DN ______________ 25 - 80Q [m3/h] _______ max. 260H [m] __________ max. 106p [bar] __________ max. 12T [°C] ________ max. +110n [min-1] ______ max. 3500

Reference no. 1213.5-10 + 4070.5-10

Close-coupled chrome steel pump with motor-mounted variable speed system

Design: Horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings. ATEX-compliant version available.

Applications: Water supply, spray irrigation, irrigation and drainage systems, hea-ting and air-conditioning systems, fire-fighting systems, handling of drinking water, service water, hot water, cooling water, swimming pool water, fire-fighting water, condensate, oil and cleaning agents.

Etachrom NC

DN ______________ 25 - 80Q [m3/h] _______ max. 260H [m] __________ max. 106p [bar] __________ max. 12T [°C] ________ max. +110Data for 50 Hz operation

Reference no. 1212.5-10 also available in 60 HzPumpMeter · Hyamaster

Standardized chrome steel pump

Design: Horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings and motor-mounted variable speed system.

Applications: Water supply, spray irrigation, irrigation and drainage systems, hea-ting and air-conditioning systems, fire-fighting systems, handling of drinking water, service water, hot water, cooling water, swimming pool water, fire-fighting water, condensate, oil and cleaning agents.

Etachrom NC PumpDrive

DN ______________ 25 - 80Q [m3/h] _______ max. 260H [m] __________ max. 106p [bar] __________ max. 12T [°C] ________ max. +110n [min-1] ______ max. 3500

Reference no. 1212.5-10 + 4070.5-10

Standardized chrome steel pump with motor-mounted variable speed system

PumpMeter

PumpMeter

Page 21: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

21Automation possible

S t a n d a r d i z e d / c l o s e - c o u p l e d p u m p s , f i x e d / v a r i a b l e s p e e d

Design: Single-stage volute casing pump, ratings to EN 733, for vertical installa-tion in closed tanks under atmospheric pressure. Up to an immersion depth of 2000 mm.

Applications: Handling of neutral degreasing and phosphatizing solutions, wash water with degreasing agents, dipping paints, etc.

Etanorm GPV/CPV

DN _____________ 32 - 150Q [m3/h] _______ max. 660H [m] __________ max. 102p [bar] __________ max. 16T [°C] _________ max. +95Data for 50 Hz operation

Reference no. 1214.5-10 also available in 60 Hz

Vertical low-pressure pump

Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Equipped with heat barrier, seal chamber air-cooled by integrated fan impeller, noexternal cooling. ATEX-compliant version available.

Applications: Handling of hot water and thermal oil in piping or tank systems, particularly in medium -sized and large hot water heating systems, forced circulation boilers, district heating systems, etc.

HPK-L

DN _____________ 25 - 250Q [m3/h] ______ max. 1330H [m] __________ max. 155p [bar] __________ max. 40T [°C] _ max. +240 / +350Data for 50 Hz operation

Reference no. 1136.5-10 also available in 60 HzPumpDrive • Hyamaster

Hot water / thermal oil recirculation pump without external cooling

Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. TÜV certification to TRD on option. ATEX-compliant version available.

Applications: Handling of hot water and thermal oil in piping or tank systems, particularly in medium-sized and large hot water heating systems, forced circulation boilers, district heating systems, etc.

HPK

Reference no. 1121.51-10 also available in 60 HzPumpDrive • Hyamaster

Hot water recirculation pump

DN ____________150 - 400Q [m3/h] ______ max. 4150H [m] __________ max. 185p [bar] __________ max. 40T [°C] ________ max. +400Data for 50 Hz operation

H o t w a t e r p u m p s

Design: Horizontal, radially split volute casing pump in back pull-out design, single-stage, single-entry, with centreline pump feet and radial impeller. TÜV certification to TRD on option. ATEX-compliant version available.

Applications: Handling of hot water in high-pressure hot water generation plants and for use as boiler feed and recirculation pump.

HPH

DN _____________ 40 - 350Q [m3/h] ______ max. 2350H [m] __________ max. 225p [bar] _________ max. 110T [°C] ________ max. +320Data for 50 Hz operation

Reference no. 1122.5-10 also available in 60 HzHyamaster

Hot water recirculation pump

Page 22: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

22

H o t w a t e r / t h e r m a l o i l p u m p s

Design: Horizontal, long-coupled volute casing pump in back pull-out design with ratings and main dimensions to EN 733, single-stage, with replaceable casing wear rings. ATEX-compliant version available.

Applications: Heat transfer systems (DIN 4754, VDI 3033) or hot water recircula-tion (DIN 4752).

Etanorm SYT / RSY

DN _____________ 32 - 300Q [m3/h] ______ max. 1900H [m] __________ max. 102p [bar] __________ max. 16T [°C] ________ max. +350Data for 50 Hz operation

Reference no. 1220.5-10 also available in 60 HzHyamaster

Hot water / thermal oil pump

Automation possible

Design: Horizontal, single-stage volute casing pump in back pull-out design with ratings and main dimensions to EN 733, or in in-line design, with replaceable casing wear rings.

Applications: Heat transfer systems (DIN 4754) or hot water recirculation.

Etabloc SYT / Etaline SYT

DN _____________ 32 - 100Q [m3/h] _______ max. 280H [m] ___________ max. 67p [bar] __________ max. 16T [°C] ________ max. +350Data for 50 Hz operation

Reference no. 1170.5-10 also available in 60 HzHyamaster

Hot water / thermal oil pump

Design: Horizontal, seal-less, single-stage volute casing pump with magnetic drive, ratings and main dimensions to EN 733, with replaceable casing wear rings.

Applications: Handling of thermal oil in heat transfer systems to DIN 4754.

Etamagno SY / SYI / Bloc SY

DN ___________ 32 - 150Q [m3/h] _______ max. 660H [m] _________ max. 102p [bar] _________ max. 16T [°C] _______ max. +350Data for 50 Hz operation

Reference no. 1218.5-10 also available in 60 HzHyamaster

Thermal oil pump

T h e r m a l o i l p u m p s w i t h m a g n e t i c d r i v e / c a n n e d m o t o r

Design: Horizontal, seal-less, single-stage pump with fully enclosed canned motor, uncooled. ATEX-compliant version available.

Applications: Handling of thermal oils and other hot fluids in heat transfer systems to DIN 4754.

HX (Nikkiso-KSB)

DN __________ 32 - 100Q [m3/h] ______ max. 200H [m] _________ max. 100p [bar] _________ max. 40T [°C] ______ max. +350Data for 50 Hz operation

also available in 60 Hz

Thermal oil pump with explosion protection

(Only available in Europe, Russia, Middle East and Africa)

Page 23: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

23

T h e r m a l o i l p u m p s w i t h m a g n e t i c d r i v e / c a n n e d m o t o r

Design: Horizontal, seal-less, single-stage pump with fully enclosed canned motor, uncooled, coolable or heatable. ATEX-compliant version available.

Applications: Handling of thermal oils and other hot fluids in heat transfer systems to DIN 4754.

HY (Nikkiso-KSB)

DN ____________ 32 - 80Q [m3/h] ______ max. 150H [m] _________ max. 100p [bar] _________ max. 40T [°C] _______ max. +250Data for 50 Hz operation

also available in 60 Hz

Thermal oil pump with explosion protection

(Only available in Europe, Russia, Middle East and Africa)

Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Also available as variant with “wet” shaft, conical seal chamber and/or semi-open impeller (CPKNO) with motor-mounted variable speed system.

Applications: Handling of aggressive liquids in the chemical and petrochemical industries as well as in refinery and fire-fighting systems, handling of brine.

DN _____________ 25 - 300Q [m3/h] ______ max. 1050H [m] __________ max. 220p [bar] __________ max. 25T [°C] ________ max. +110n [min-1] ______ max. 3600

Reference no. 2730.5-10 + 4070.5-10

Standardized chemical pump with reinforced bearing bracket and motor-mounted variable speed systemCPKN PumpDrive

CPK-D

DN _____________ 32 - 250Q [m3/h] ______ max. 1100H [m] __________ max. 128p [bar] __________ max. 25T [°C] ________ max. +150 Data for 50 Hz operation

Reference no. 2726.1-10 also available in 60 HzHyamaster

Standardized chemical pump with hydrodynamic shaft seal

Design: Horizontal, radially split volute casing pump in back pull-out design to ISO 2858, single-stage, single-entry, with radial impeller and zero-leakage hydrodynamic shaft seal.

Applications: Handling of liquids in the chemical and petrochemical industry, in refineries and paint shops.

S t a n d a r d i z e d c h e m i c a l p u m p s

Reference no. 2730.5-10 also available in 60 Hz

CPKN Standardized chemical pump with reinforced bearing bracket

Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Also available as variant with “wet” shaft, conical seal chamber, heatable volutecasing (CPKN-CHs) and/or semi-open impeller (CPKNO). ATEX-compliant version available. Applications: Handling of aggressive liquids in the chemical and petrochemicalindustries as well as in refinery and fire-fighting systems, handling of brine.

DN _____________ 25 - 400Q [m3/h] ______ max. 4150H [m] __________ max. 185p [bar] __________ max. 25T [°C] ________ max. +400Data for 50 Hz operation

Hyamaster

Automation possibleFactory-automated

Page 24: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

24 Automation possible

Design: Horizontal, seal-less, close-coupled, mag-drive volute casing pump to ISO 2858 / EN 22 858 / ISO 5199, single-stage, single-entry, with radial impeller. ATEX-compliant version available.

Applications: Handling of aggressive, toxic, explosive, valuable, flammable, mal odorous or harmful liquids in the chemical, petrochemical and general industry.

Magnochem - Bloc

DN _____________ 25 - 125Q [m3/h] _______ max. 240H [m] __________ max. 153p [bar] __________ max. 25T [°C] ________ max. +250Data for 50 Hz operation

Reference no. 2749.5-10 also available in 60 HzHyamaster

Close-coupled chemical pump with mag-drive

Design: Horizontal / vertical, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single-entry, pump casing connecting dimensions to EN 733.

Applications: Handling of aggressive, flammable, toxic, volatile, or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.

Etaseco / Etaseco-I

DN _____________ 32 - 100Q [m3/h] _______ max. 250H [m] __________ max. 100p [bar] __________ max. 16T [°C] ________ max. +140Data for 50 Hz operation

Reference no. 2935.5-10 also available in 60 HzPumpMeter • Hyamaster • PumpDrive

Water motor pumps with canned motor

Design: Horizontal, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single -entry, casing connecting dimensions to EN 22 858 / ISO 2858. Design to ATEX.

Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.

Secochem Ex

DN _____________ 25 - 100Q [m3/h] _______ max. 300H [m] __________ max. 150p [bar] __________ max. 25T [°C] ________ max. +130Data for 50 Hz operation

Reference no. 2939.5-10 also available in 60 HzHyamaster

Standardized chemical pump with canned motor and explosion protection

S e a l - l e s s p u m p s

Design: Horizontal, seal-less, mag-drive volute casing pump in back pull-outdesign to ISO 2858 / EN 22 858 / ISO 5199, single-stage, single-entry, with radial impeller. ATEX-compliant version available.

Applications: Handling of aggressive, toxic, explosive, valuable, flammable, malodorous or harmful liquids in the chemical, petrochemical and general industry.

Magnochem

DN ____________ 25 - 250Q [m3/h] ______ max. 1250H [m] __________ max. 153p [bar] __________ max. 25T [°C] ________ max. +300Data for 50 Hz operation

Reference no. 2739.5-10 also available in 60 HzHyamaster

Standardized chemical pump with mag-drive

Design: Horizontal/vertical seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single-entry.

Applications: Pump for handling toxic, volatile or valuable fluids in environmen-tal and industrial engineering and for use as a coolant pump in cooling systems. Transport vehicles, environmental and industrial engineering; applications where low noise emission, smooth running or long service intervals are required.

Etaseco RVP

DN __________________ 32Q [m3/h] ________ max. 20H [m] ___________ max. 25p [bar] __________ max. 10T [°C] _________ max. +85

Reference no. 2935.17-10 also available in 60 HzPumpMeter • PumpDrive

Cooling circuit pump with canned motor

Page 25: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

25Automation possible

S e a l - l e s s p u m p s

Design: Horizontal, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single -entry, pump casing connecting dimensions to EN 22 858 / ISO 2858, with external cooler. Design to ATEX.

Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.

Secochem Ex K

DN _____________ 25 - 100Q [m3/h] _______ max. 300H [m] __________ max. 150p [bar] __________ max. 25T [°C] ________ max. +400Data for 50 Hz operation

Reference no. 2939.51-10 also available in 60 HzHyamaster

Standardized chemical pump with canned motor and explosion protection

Design: Horizontal (HN) or vertical (BN / TN), seal-less, single-stage pump with fully enclosed canned motor, uncooled, coolable or heatable. ATEX-compliant version available.

Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry.

HN / BN / TN (Nikkiso-KSB)

DN _____________ 32 - 300Q [m3/h] _______ max. 800H [m] __________ max. 200p [bar] __________ max. 40T [°C] ________ max. +180Data for 50 Hz operation

also available in 60 Hz

Chemical canned motor pump with explosion protection

Design: Horizontal (HT) or vertical (BT /TT), seal-less, single-stage pump with fully enclosed canned motor, coolable. ATEX-compliant version available.

Applications: Handling of aggressive, solids-containing, polymerizing, flammable, explosive, toxic, volatile or valuable liquids as well as thermal oils in the chemical and petrochemical industry.

HT / BT / TT (Nikkiso-KSB)

DN _____________ 32 - 300Q [m3/h] _______ max. 800H [m] __________ max. 200p [bar] __________ max. 40T [°C] ________ max. +400Data for 50 Hz operation

also available in 60 Hz

Chemical canned motor pump with explosion-protection for special applications

Design: Horizontal, seal-less pump with fully enclosed canned motor, two-stage design in tandem arrangement. ATEX-compliant version available.

Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry. For small flow rates, high discharge heads and low NPSHR.

HK (Nikkiso-KSB)

DN ______________ 25 - 40Q [m3/h] ________ max. 10H [m] __________ max. 300p [bar] __________ max. 40T [°C] ________ max. +150n [min-1] ______ max. 8400Data for n = 8400 min-1

high speed, up to 130 Hz

Two-stage canned motor pump with explosion protection

Design: Horizontal, seal-less pump with fully enclosed canned motor, multistage. ATEX-compliant version available.

Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry. For high discharge heads.

VN (Nikkiso-KSB)

DN _____________ 40 - 100Q [m3/h] _______ max. 140H [m] __________ max. 450p [bar] __________ max. 40T [°C] ________ max. +180Data for 50 Hz operation

also available in 60 Hz

Multistage canned motor pump with explosion protection

(Only available in Europe, Russia, Middle East and Africa)

(Only available in Europe, Russia, Middle East and Africa)

(Only available in Europe, Russia, Middle East and Africa)

(Only available in Europe, Russia, Middle East and Africa)

Page 26: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

26

S e a l - l e s s p u m p s

Design: Horizontal, seal-less pump with fully enclosed canned motor, single stage, self-priming. ATEX-compliant version available.

Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry. Self-priming pump for draining of tanks and unloading of tanks and tank trucks.

DN (Nikkiso-KSB)

DN ______________ 32 - 50Q [m3/h] ________ max. 40H [m] ___________ max. 60p [bar] __________ max. 40T [°C] ________ max. +180Data for 50 Hz operation

also available in 60 Hz

Self-priming canned motor pump with explosion protection

(Only available in Europe, Russia, Middle East and Africa)

P r o c e s s p u m p s

Design: Horizontal, radially split volute casing pump in back pull-out design to API 610, 10th edition, or ISO 13709 (heavy duty), with radial impeller, single-stage, single-entry, centreline pump feet; with inducer, if required. ATEX-compliant version available.

Applications: Refineries, petrochemical and chemical industry, power stations.

RPH

DN _____________ 25 - 400Q [m3/h] ______ max. 4150H [m] __________ max. 270p [bar] __________ max. 51T [°C] ________ max. +450Data for 50 Hz operation

Reference no. 1312.5-10 / 1316.51 -10 also available in 60 HzHyamaster

Process pump

Design: Radially split, vertical shaft submersible pump with double volute for wet and dry installation, single- or double-stage, single-entry, with radial impeller; heatable model available. ATEX-compliant version available.

Applications: Handling of chemically aggressive liquids, also slightly contaminated or with a low solids content, in the chemical and petrochemical industry.

CTN

DN _____________ 25 - 250Q [m3/h] _______ max. 800H [m] ___________ max. 93p [bar] __________ max. 16T [°C] ________ max. +300Data for 50 Hz operation

Reference no. 2711.5-10 also available in 60 Hz

Chemical vertical shaft submersible pump

Design: Horizontal or vertical canned motor pump to API 685, single-stage, with centreline pump feet; also available with inducer.

Applications: HNP: for clean liquids; HTP: for hot fluids; HSP / HMP: for contam-inated or polymerising fluids; HRP: for fluids with a steep vapour pressure curve such as liquefied gases.

API series (Nikkiso-KSB)

DN ______________ 1½ - 6Q [m3/h] _______ max. 360H [m] __________ max. 220p [bar] __________ max. 40T [°C] ________ max. +450Data for 50 Hz operation

also available in 60 Hz

Refinery pump

(Only available in Europe, Russia, Middle East and Africa)

Automation possible

Page 27: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

27

C e n t r i f u g a l p u m p f o r m i n i m a l v o l u m e f l o w s

A

Design: System consisting of a variable-speed single-stage centrifugal pump with directly flanged motor and control unit.

Applications: Continuous volume flow control for handling aggressive organic and inorganic fluids in chemical and pharmaceutical processes. The pump is suitable for use in laboratories, pilot plants and in production processes, particularly in industrial process engineering, continuous processes, micro-process engineering, miniplants, dosing, coating, spray-drying and injection applications.

Microchem

Q [ml/min] _____ 0 to 5000H [m] __________ max. 200p [bar] __________ max. 25T [°C] _______ -10 to +100

Reference no. 2600.5-10

Centrifugal pump for minimal volume flows

R a i n w a t e r h a r v e s t i n g s y s t e m s

A

Design: Ready-to-connect package rainwater harvesting system. Automatic mains water back-up if the rain water storage tank is empty, with integrated dry-running protection. Automated with automatic control unit.

Applications: Rainwater and service water utilization, irrigation and spray irrigation systems.

Hya-Rain / Hya-Rain N

Rp ___________________ 1Q [m3/h] _________ max. 4H [m] ___________ max. 43p [bar] ___________ max. 6T [°C] _________ max. +35Data for 50 Hz operation

Reference no. 5602.51-10

Rainwater harvesting system with one pump

A

Design: Ready-to-connect package rainwater harvesting system. Automatic mains water back-up function if the rain water storage tank is empty, with integrated dry-running protection.

Applications: Rainwater and service water utilization, irrigation and spray irrigation systems.

Hya-Rain Eco

Rp ___________________ 1Q [m3/h] _________ max. 4H [m] ___________ max. 43p [bar] ___________ max. 6T [°C] _________ max. +35Data for 50 Hz operation

Reference no. 5605.5-10

Rainwater harvesting system with one pump

Factory-automated

Page 28: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

28

D o m e s t i c w a t e r s u p p l y s y s t e m s

w i t h a u t o m a t i c c o n t r o l u n i t / s w i m m i n g p o o l s

Design: Multistage, self-priming centrifugal pump in close-coupled design.

Applications: Single- or two-family houses, agricultural facilities, spray irrigation and irrigation systems, washing plants, water supply and rainwater harvesting systems.

Multi Eco

Rp _______________ 1-1¼

Q [m3/h] _________ max. 8H [m] ___________ max. 54p [bar] __________ max. 10T [°C] _________ max. +50n [min-1] ______ max. 2800

Reference no. 5180.5-10Controlmatic • Cervomatic

Multistage, self-priming centrifugal pump

Design: Multistage, self-priming centrifugal pump in close-coupled design, withpower cable, plug and Controlmatic E automatic control unit switching the pump on and off as consumers are opened / closed and protecting the pump against dry running. Automated with automatic control unit.

Applications: Single- or two-family houses, agricultural facilities, spray irrigation and irrigation systems, washing plants, water supply and rainwater harvesting systems.

Multi Eco-Pro

Rp _______________ 1-1¼

Q [m3/h] _________ max. 8H [m] ___________ max. 54p [bar] __________ max. 10T [°C] _________ max. +50n [min-1] ______ max. 2800

Reference no. 5182.5-10

Multistage, self-priming centrifugal pump with automatic control unit

Automation possibleFactory-automated

A

Design: Multistage, self-priming centrifugal pump in close-coupled design incl.accumulator with replaceable membrane in drinking water quality, total volume 20 or 50 l, pressure switch for automatic pump operation and 1.5 m power cable. Automated with automatic control unit.

Applications: Single- or two-family houses, agricultural facilities, spray irrigation and irrigation systems, washing plants, water supply and rainwater harvesting systems.

Multi Eco-Top

Rp _______________ 1-1¼

Q [m3/h] _________ max. 8H [m] ___________ max. 54p [bar] ___________ max. 7T [°C] _________ max. +50n [min-1] ______ max. 2800

Reference no. 5181.5-10

Domestic water supply system

A

Design: Multistage, vertical (horizontal installation upon request) high-pressure centrifugal pump, with suction and discharge nozzles of identical nominal diameters arranged opposite to each other (in-line design).

Applications: Single- or two-family houses, agricultural facilities, spray irrigation and irrigation systems, washing plants, water supply and rainwater harvesting systems, pressure boosting, hot water and cooling water recirculation, fire-fighting systems.

Movitec VME

Rp _________________ 1½Q [m3/h] _________ max. 9H [m] ___________ max. 48p [bar] __________ max. 16T [°C] _________ max. +60n [min-1] ______ max. 2900Data for 50 Hz operation

Reference no. 1798.5-10 also available in 60 HzPumpMeter • Hyamaster

High-pressure in-line pump in close-coupled design

Design: Fully or partly submerged, multistage, close-coupled centrifugal pump (min. immersion depth 0.1 m), low-level inlet, suction strainer with a max. mesh size of 2.5 mm.

Applications: Water supply, spray irrigation and irrigation systems, washing plants, rainwater harvesting systems, water extraction from wells, tanks and cisterns.

Ixo

Rp _________________ 1¼Q [m3/h] _________ max. 8H [m] ___________ max. 65T [°C] _________ max. +35n [min-1] ______ max. 2900

Reference no. 2146.5-10Switchgears • Cervomatic

Submersible motor pump

Page 29: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

29Factory-automated

D o m e s t i c w a t e r s u p p l y s y s t e m s

w i t h a u t o m a t i c c o n t r o l u n i t / s w i m m i n g p o o l s

A

Design: Self-priming, single-stage, close-coupled centrifugal pump.

Applications: Handling of clean or slightly contaminated water, swimming pool water with a chlorine content of up to 0.3 %, ozonized swimming pool water with a salt content of up to 7 ‰.

Filtra N

Rp ___________________ 2Q [m3/h] ________ max. 36H [m] ___________ max. 21p [bar] _________ max. 2.5T [°C] _________ max. +35n [min-1] ______ max. 2800

Reference no. 2127.5-10

Recirculating pump for swimming pool filtering systems

P r e s s u r e b o o s t e r s y s t e m s

A

Design: Fully automatic package single-pump system with 8 l membrane-type accumulator, pressure-controlled starting and flow-controlled stopping. Automated with automatic control unit.

Applications: Water supply systems for residential and office buildings, irrigation/spray irrigation and rainwater harvesting systems, service water supply systems in trade and industry.

Hya-Solo E

Rp _________________ 1¼

Q [m3/h] _________ max. 6H [m] ___________ max. 50p [bar] __________ max. 10T [°C] _________ max. +60Data for 50 Hz operation

Reference no. 1951.5-10

Pressure booster system, 1 pump

A

Design: Fully automatic package single-pump system with 8 l membrane-type accumulator, pressure-controlled starting and stopping.

Applications: For industrial plants, water supply systems for residential and office buildings, irrigation/spray irrigation and rainwater harvesting systems, service water supply systems in trade and industry.

Hya-Solo D

Rp / DN ________ 1¼ / 100Q [m3/h] _______ max. 110H [m] __________ max. 150p [bar] __________ max. 16T [°C] _________ max. +70Data for 50 Hz operation

Reference no. 1951.5-10

Pressure booster system, 1 pump

A

Design: Fully automatic variable-speed package single-pump system with PumpDrive, pressure-controlled starting and flow-controlled stopping. Automated with PumpDrive.

Applications: For industrial plants, water supply systems for residential and office buildings, irrigation/spray irrigation and rainwater harvesting systems, service water supply systems in trade and industry.

Hya-Solo DV

Rp / DN ________ 1¼ / 100Q [m3/h] _______ max. 110H [m] __________ max. 150p [bar] __________ max. 16T [°C] _________ max. +70Data for 2900 min-1

Reference no. 1951.5-10

Pressure booster system, 1 pump

Page 30: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

30

A

Design: Fully automatic package pressure booster system, with 2 to 3 vertical high-pressure pumps, fully electronic control to ensure the required supply pressure, standard version with volt-free changeover contact for general fault indication and live-zero monitoring of the connected sensors, configuration and functions to DIN 1988, Part 5. Automated with BoosterControl.

Applications: Residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.

Hya-Eco K

Rp / DN ___________ 2 / 80Q [m3/h] ________ max. 70H [m] __________ max. 100p [bar] __________ max. 10T [°C] _________ max. +70Data for 50 Hz operation

Reference no. 1967.5-10

Pressure booster system, 2 to 3 pumps

A

Design: Fully automatic package pressure booster system, with 2 to 3 vertical high-pressure pumps and continuously variable speed adjustment of each pump for fully electronic control of the required supply pressure, with two standard volt-free changeover contacts for fault indication. Configuration and function to DIN 1988, Part 5. Automated with BoosterControl.

Applications: Residential buildings, hospitals, office buildings, hotels, department stores, industry, and other applications.

Hya-Eco VP

Rp / DN ___________ 2 / 80Q [m3/h] ________ max. 70H [m] __________ max. 120p [bar] __________ max. 12T [°C] _________ max. +70Data for 3500 min-1

Reference no. 1967.52-10

Pressure booster system with continuously variable speed control of each pump

Design: Fully automatic package pressure booster system, with 2 to 6 vertical high-pressure pumps, fully electronic control to ensure the required supply pres-sure, with volt-free changeover contact for general fault indication and live-zero monitoring of the connected sensors, configuration and functions to DIN 1988, Part 5. Automated with BoosterControl.

Applications: Residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.

Hyamat K

Rp / DN ________ 1½ / 250Q [m3/h] _______ max. 660H [m] __________ max. 160p [bar] __________ max. 16T [°C] _________ max. +70Data for 50 Hz operation

Reference no. 1952.5-10

Pressure booster system, 2 to 6 pumps

Hyamat V Pressure booster system with continuously variable speed adjustment of one pump

Design: Fully automatic package pressure booster system, with 2 to 6 vertical high-pressure pumps and continuously variable speed adjustment of one pump for fully electronic control of the required supply pressure. Configuration and functions to DIN 1988, Part 5. Automated with BoosterControl.

Applications: Pressure boosting in residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.

Rp / DN ________ 1½ / 250Q [m3/h] _______ max. 660H [m] __________ max. 160p [bar] __________ max. 16T [°C] _________ max. +70Data for 2900 min-1

Reference no. 1953.51-10

Design: Fully automatic package pressure booster system, with 2 to 6 vertical high-pressure pumps and continuously variable speed control of each pump byPumpDrive speed control system. For fully electronic control of the required sup-ply pressure. Configuration and functions to DIN 1988, Part 5. Automated with BoosterControl and PumpDrive.

Applications: Pressure boosting in residential buildings, hospitals, office buildings, hotels, department stores, industry, etc.

Hyamat VP

Rp / DN ________ 1½ / 250Q [m3/h] _______ max. 660H [m] __________ max. 160p [bar] __________ max. 16T [°C] _________ max. +70Data for 2900 min-1

Reference no. 1953.52-10

Pressure booster system with continuously variable speed control of each pump

P r e s s u r e b o o s t e r s y s t e m s

Factory-automated

Page 31: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

31

P r e s s u r e b o o s t e r s y s t e m s

A

Design: Fully automatic package pressure booster system, with 2 to 4 vertical high-pressure pumps and fully electronic control to ensure the required supply pressure, configuration and functions to DIN 1988, Part 5. Automated with PLC.

Applications: Handling of service water and cooling water not chemically or mechanically aggressive to the pump materials in industry, etc.

Hyamat IK, IV, IVP

DN ____________ 100 - 200Q [m3/h] _______ max. 640H [m] __________ max. 160p [bar] __________ max. 16T [°C] _________ max. +70Data for 50 Hz operation

Reference no. 1950.5-10

Pressure booster system for industrial applications

D r a i n a g e p u m p s / w a s t e w a t e r p u m p s

Design: Vertical, fully floodable submersible motor pump in close-coupled design, IP 68, single-stage, with or without level control, max. immersion depth 2 m.

Applications: Automatic drainage of pits, shafts, yards and cellars subject to a flooding risk, lowering of surface water levels, dewatering, drainage of under-ground passages, water extraction from rivers and reservoirs.

Ama-Drainer N 301, 302, 303, 358

Rp _____________ 1¼ - 1½

Q [m3/h] ________ max. 17H [m] ___________ max. 12T [°C] _________ max. +35Data for 50 Hz operation

Reference no. 2331.51-10 / 2331.52-10 Switchgears • LevelControl

Submersible motor pump

Design: Vertical, fully floodable submersible motor pump in close-coupled design, IP 68, single-stage, with or without level control, max. immersion depth 10 m.

Applications: Automatic drainage of pits, shafts, yards and cellars subject to a flooding risk, lowering of surface water levels, dewatering, drainage of under-ground passages, water extraction from rivers and reservoirs, disposal of highly contaminated, fibre-containing water.

Ama-Drainer 400/10 400/35 500/10/11

Rp ______________ 1½ - 2Q [m3/h] ________ max. 50H [m] ___________ max. 24T [°C] _________ max. +40Data for 50 Hz operation

Reference no. 2331.53-10Switchgears • LevelControl

Submersible motor pump

Design: Vertical, fully floodable submersible motor pump in close-coupled design, IP 68, single-stage, with or without level control, max. immersion depth 10 m.

Applications: Automatic drainage of pits, shafts, yards and cellars subject to a flooding risk, lowering of surface water levels, dewatering, drainage of under-ground passages, water extraction from rivers and reservoirs.

Ama-Drainer 80, 100

Rp / DN _______ 2½ / 100Q [m3/h] _______ max. 130H [m] ___________ max. 26T [°C] _________ max. +50Data for 50 Hz operation

Reference no. 2331.54-10Switchgears • LevelControl

Submersible motor pump

Automation possibleFactory-automated

Page 32: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

32

Design: Vertical, fully floodable submersible waste water pump in close-coupleddesign (cast iron variant), single-stage, without explosion protection.

Applications: Handling of all types of waste water.

Ama-Porter F / S / ICS

DN ______________ 50 - 65Q [m3/h] ________ max. 40H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation

Reference no. 2541.51-10 / 2539.51-10 / 2539.52-10 / 2539.53-10(ICS)

Submersible motor pump

Design: Vertical, single-stage centrifugal pump with discharge to the top and par-allel with the pump shaft, pump foot designed as suction strainer. Pump and motor are rigidly connected by a support pipe, ready to be plugged in, with 1.5 m power cable and level switch.Applications: Automatic disposal of waste water from buildings, pits and tanks, lowering of surface water levels and drainage.

Rotex

Rp ______________ 1¼ - 2Q [m3/h] ________ max. 24H [m] ___________ max. 14T [°C] _________ max. +90Data for 50 Hz operation

Reference no. 2322.5-10

Waste water pump

Switchgears • LevelControl (Ama-Porter F/S)

D r a i n a g e p u m p s / w a s t e w a t e r p u m p s

Design: Vertical submersible pump with three-channel impeller, volute casing designed as suction strainer.

Applications: Handling of condensate and heat transfer liquids below the boiling point, condensate return systems, primary and secondary heating circuits, direct installation in heating tanks or heat exchangers in the secondary circuits of heat transfer systems (MKY).

MK / MKY

Rp / DN ___________ 2 / 50Q [m3/h] ________ max. 36H [m] ___________ max. 19T [°C] ________ max. +200Data for 50 Hz operation

Reference no. 2324.5-10Switchgears • LevelControl

Waste water, condensate and heat transfer liquid pump

Automation possibleFactory-automated

Page 33: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

33

L i f t i n g u n i t s / c o l l e c t i n g t a n k s

Design: Stable above-floor or impact-resistant underfloor plastic collecting tankwith floor drain and odour trap, both variants with Ama-Drainer submersible motor pump starting and stopping automatically and swing check valve. Automated with switchgears and LevelControl.Applications: Wash-basins, showers, washing machines, garage gateways, base-ments, rooms subject to a flooding risk, etc.

Ama-Drainer-Box

DN ______________ 40 - 50Q [m3/h] ________ max. 35H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation

Reference no. 2331.55-10

Automatic waste water lifting unitReleased for sale until March 2011 –

to be superseded by new Ama Drainer Box.

Design: Floodable single-pump or dual-pump sewage lifting unit for automatic disposal of domestic sewage and faeces below the flood level. Automated with LevelControl.

Applications: Basement flats, bars, basement party rooms and saunas, cinemas and theatres, department stores and hospitals, hotels, restaurants, schools, etc.

mini-Compacta

DN _____________ 32 - 100Q [m3/h] ________ max. 36H [m] ___________ max. 25T [°C] _________ max. +40Data for 50 Hz operation

Reference no. 2317.54-10

Floodable sewage lifting unit

Design: Floodable single-pump or dual-pump sewage lifting unit for automatic disposal of sewage and faeces below the flood level. Automated with LevelControl.

Applications: Basement flats, bars, basement party rooms and saunas, cinemas and theatres, department stores and hospitals, hotels, restaurants, schools, public buildings, industrial plants, joint sewage disposal for rows of houses, etc.

Compacta®

DN _____________ 80 - 100Q [m3/h] _______ max. 140H [m] ___________ max. 24T [°C] _______ max. +40*Data for 50 Hz operation

Reference no. 2317.55-10

Floodable sewage lifting unit

* up to +65 °C for short periods

A

Design: Ready-to-connect package single or dual pumping station with PE-LLD(polyethylene) collecting tank for underground installation. Equipped with one or two Amarex N S and Ama-Porter submersible waste water pumps without explo-sion protection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476. Automated with LevelControl.

Applications: Renovation of premises, sewage disposal in various sectors, joint sewage disposal for several residential units, pumped drainage.

Pumping Station CK 800-Eu

DN ______________ 32 - 50Q [m3/h] ________ max. 22H [m] ___________ max. 49T [°C] _________ max. +40Data for 50 Hz operation

Reference no. 2334.541-10

Pumping station, plastic collecting tank with Amarex N S and Ama-Porter

Factory-automated

Page 34: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

34

L i f t i n g u n i t s / c o l l e c t i n g t a n k s

LevelControl

Design: Ready-to-connect package single or dual pumping station with PE-LLD(polyethylene) collecting tank for underground installation. Equipped with one or two Amarex N submersible waste water pumps, also available with explosion pro-tection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476. Automated with LevelControl.

Applications: Renovation of premises, sewage disposal in various sectors, joint sewage disposal for several residential units, pumped drainage.

Amarex N CK Pumping Station

DN ______________ 50 - 65Q [m3/h] ________ max. 50H [m] ___________ max. 39T [°C] _________ max. +40Data for 50 Hz operation

Pumping station, plastic collecting tank with Amarex N

Reference no. 2334.52-10

LevelControl

Design: Single-pump or dual-pump sewage lifting unit with one or two Ama-Porter submersible waste water pumps with free-flow impeller (F) or cutter (S), to EN 12050-1.

Applications: Disposal of domestic waste water and sewage.

Evamatic-Box

DN ______________ 50 - 65Q [m3/h] ________ max. 40H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation

Sewage lifting unit

Reference no. 2319.51-10

LevelControl

Design: Single-pump or dual-pump sewage lifting unit with one or two Ama-Porter ICS submersible waste water pumps with free-flow impeller (F) or cutter (S) and ICS control system.

Applications: Disposal of domestic waste water and sewage.

Evamatic-Box ICS

DN ______________ 50 - 65Q [m3/h] ________ max. 40H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation

Sewage lifting unit

Reference no. 2319.52-10

Released for sale until March 2011 –

to be superseded by Evamatic Box N.

Released for sale until March 2011 –

to be superseded by Evamatic Box N ICS.

A

Design: Ready-to-connect package single or dual pumping station with PE-LLD(polyethylene) collecting tank for underground installation. Equipped with one or two Ama-Porter submersible waste water pumps without explosion protection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476. Automated with switchgears and LevelControl.

Applications: Renovation of premises, sewage disposal in various sectors, joint sewage disposal for several residential units, pumped drainage.

Ama-Porter CK Pumping Station

DN ______________ 50 - 65Q [m3/h] ________ max. 40H [m] ___________ max. 21T [°C] _________ max. +40Data for 50 Hz operation

Reference no. 2334.51-10

Pumping station, plastic collecting tank with Ama-Porter

Factory-automated

Page 35: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

35

S u b m e r s i b l e m o t o r p u m p s

Design: Vertical, single-stage submersible motor pump, for wet installation, stationary and transportable design. Amarex N pumps are floodable, single-stage, single-entry close-coupled units which are not self-priming. ATEX-compliant version available.

Applications: Handling of all types of waste water, especially untreated sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge, dewatering / water extraction, drainage of rooms and surfaces subject to a flooding risk.

Amarex N

DN _____________ 32 - 100Q [m3/h] _______ max. 190H [m] ___________ max. 49T [°C] _________ max. +55Data for 50 Hz operation

Reference no. 2563.5-10 also available in 60 HzSwitchgears • LevelControl

Submersible motor pump DN 32 to 100

Design: Vertical, single-stage submersible motor pump in close-coupled design, various impeller types, for wet or dry installation, stationary and transportable version. ATEX-compliant version available.

Applications: Handling of all types of abrasive or aggressive waste water in water and waste water engineering as well as industry, especially untreated sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge; sea water desalination.

Amarex KRT

DN _____________ 40 - 700Q [m3/h] _____ max. 10800H [m] __________ max. 100T [°C] _________ max. +60n [min-1] ______ max. 2900Data for 50 Hz operation

Submersible motor pump DN 40 to DN 700

PumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl Reference no. 2553.5-10 also available in 60 Hz

Design: Vertical, single-stage submersible motor pump in close-coupled design, various impeller types, dry installation.

Applications: Handling of all types of waste water in waste water engineering and industry, especially sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge.

Amarex KRT dry-installed, with cooling jacket

DN ___________ 100 - 700Q [m3/h] _____ max. 10000H [m] __________ max. 100p [bar] __________ max. 10T [°C] _________ max. +40n [min-1] ______ max. 1450Data for 50 Hz operation

Reference no. 2553.5-10 also available in 60 HzPumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl

Submersible motor pump DN 100 to DN 700

Design: Horizontal or vertical single-stage submersible motor pump in close-coupled design, with various impeller types, for wet or dry installation, stationary and transportable version, with energy-saving motor.

Applications: Handling of all types of waste water in waste water engineering and industry, especially sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge.

Amarex KRT wet/dry-installed, with energy-saving motor

DN _____________ 80 - 200Q [m3/h] _______ max. 550H [m] ___________ max. 25T [°C] _________ max. +40n [min-1] ______ max. 1450Data for 50 Hz operation

Reference no. 2553.5-10 also available in 60 HzPumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl

Submersible motor pump DN 80 to DN 200

Automation possible

Page 36: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

36

S u b m e r s i b l e p u m p s i n d i s c h a r g e t u b e s

Design: Wet-installed submersible motor pump with mixed flow impeller, single-stage, for installation in discharge tubes. ATEX-compliant version available.

Applications: Handling of water without stringy substances in irrigation and drainage pumping systems, general water supply systems, water pollution and flood control systems.

Amacan S

DN __________ 650 - 1300 Q [m3/h] _____ max. 10800H [m] ___________ max. 40T [°C] _________ max. +30n [min-1] ______ max. 1450Data for 50 Hz operation

Reference no. 1589.5-10 also available in 60 HzHyamaster • Amacontrol

Submersible motor pump with mixed flow impeller

Design: Wet-installed, submersible motor pump with axial propeller in ECB designfor installation in discharge tubes, single-stage, single-entry. ATEX-compliant version available.

Applications: Irrigation and drainage pumping stations, stormwater pumping stations, handling of raw and clean water in water and effluent treatment plants, of cooling water in power stations and industrial plants, industrial water supply systems, water pollution and flood control systems, aquaculture.

Amacan P

DN __________ 500 - 1500Q [m3/h] _____ max. 25200H [m] ___________ max. 12T [°C] _________ max. +40n [min-1] ______ max. 1450Data for 50 Hz operation

Reference no. 1580.5-10 also available in 60 HzHyamaster • Amacontrol

Submersible motor pump with axial propeller

Design: Wet-installed submersible motor pump with non-clogging impeller, single-stage, single-entry, for installation in discharge tubes. ATEX-compliant version available.

Applications: Handling of pre-cleaned, chemically neutral waste water, industrial effluents and sewage, fluids not containing any stringy substances pre-treated by screens and sills, as waste water, mixed water and activated sludge pump in effluent treatment plants, irrigation and drainage pumping systems.

Amacan K

DN __________ 700 - 1400 Q [m3/h] ______ max. 7200H [m] ___________ max. 30T [°C] _________ max. +40n [min-1] _______ max. 980Data for 50 Hz operation

Reference no. 1579.5-10 also available in 60 HzHyamaster • Amacontrol

Submersible motor pump with non-clogging impeller

M i x e r s / a g i t a t o r s / t a n k c l e a n i n g u n i t s

Design: Horizontal submersible mixer with self-cleaning ECB propeller, close- coupled design, direct drive or with gear unit. ATEX-compliant version available.

Applications: Handling of municipal and industrial waste water and sludges, also in environmental engineering (biogas plants, etc.).

Amamix

Propeller ø [mm] _ 200 - 600Install. depth [m] _ max. 30T [°C] _________ max. +40n [min-1] ______ max. 1400Data for 50 Hz operation

Reference no. 1592.551-10 / 1592.552-10 also available in 60 Hz

Submersible mixer

Automation possible

Page 37: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

37Automation possible

M i x e r s / a g i t a t o r s / t a n k c l e a n i n g u n i t s

Design: Horizontal submersible agitator with self-cleaning ECB propeller, close- coupled design, equipped with coaxial spur gear. ATEX-compliant version available.

Applications: In environmental engineering, particulary for circulating, keeping in suspension and inducing flow in municipal and industrial waste water and sludges; in nitrification and denitrification tanks, activated sludge tanks, mixing tanks, final storage tanks, biological phosphate elimination tanks, flocculation tanks and in biogas applications.

Amaprop

Propeller ø [mm] _ 1000 - 2500Install. depth [m] _ max. 30T [°C] _________ max. +40n [min-1] _______ max. 109

Reference no. 1592.505-10

Submersible agitator

Design: Stationary or portable unit with horizontal or vertical submersible motor propulsive jet pump with non-clogging free-flow impeller. Motor rating 5.5 to 27 kW. Available variants: Amajet, SewerAmajet, SwingAmajet, MultiAmajet.

Applications: Cleaning of stormwater tanks and storage sewers.

Amajet

DN ____________ 100 - 150 Q [m3/h] _______ max. 195T [°C] _________ max. +40n [min-1] ______ max. 1450

Reference no. 1574.5-10

Cleaning system

Design: Wet-installed, horizontal propeller pump with submersible motor, equipped with spur gear or direct drive, ECB propeller with 3 rigid, fibre-repellent blades, bolt-free connection to the discharge pipe. ATEX-compliant version available.

Applications: Recirculation of activated sludge in waste water treatment systems.

Amaline

DN ____________ 300 - 800 Q [m3/h] ______ max. 5400H [m] ____________ max. 2T [°C] _________ max. +40n [min-1] _______ max. 960

Reference no. 1594.5-10

Submersible motor recirculation pump

P u m p s f o r s o l i d s - l a d e n f l u i d s

Design: Horizontal or vertical volute casing pump with free-flow (F), single vane (E), multi-vane (K) and diagonal single vane (D) impellers, discharge flange to DIN and ANSI standards. ATEX-compliant version available.

Applications: Handling of sewage and all types of waste water in waste water management and industry.

Sewatec / Sewabloc

DN _____________ 50 - 700 Q [m3/h] _____ 60 - 10000H [m] ___________ max. 95p [bar] __________ max. 10T [°C] _________ max. +70n [min-1] ______ max. 2900Data for 50 Hz operation

Reference no. 2580.5-10/2580.45-10/2580.35-10 also available in 60 HzHyamaster • PumpDrive • LevelControl

Dry-installed volute casing pump

Page 38: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

38

Design: Horizontal, radially split volute casing pump in back pull-out or close-coupled design, single-stage, single-entry, available with various impeller types:non-clogging impeller, open multi-vane impeller, free-flow impeller. ATEX-compliant version available.

Applications: Handling of pre-treated sewage, waste water, all types of slurries without stringy substances and pulps up to 5 % bone dry.

KWP / KWP-Bloc

DN __ 40 - 900 (max. 1000)Q [m3/h] _____ max. 15000 ______________ (18000)H [m] __________ max. 100p [bar] __________ max. 10T [°C] _ +120 (max. +280)n [min-1] ______ max. 2900Data for 50 Hz operation

Reference no. 2361.5-10/2362.5-10/2361.450-10/2361.453-10/2361.460-10 also available in 60 HzHyamaster

Non-clogging impeller centrifugal pump / close-coupled unit

P u m p s f o r s o l i d s - l a d e n f l u i d s

Automation possible

S l u r r y p u m p s

Design: Patented design incorporates state-of-the art hydraulic and wear tech-nologies for heavy-duty, high-pressure applications. The pump shell is designed to reduce stresses that can cause a structural failure during a pressure surge.

Applications: Ideal for ore and tailings transport to minimize the effect of sudden pressure spikes.

WBC

Q [m3/h] _____ max. 13600H [m] ___________ max. 80p [bar] __________ max. 40T [°C] ________ max. +120

Slurry pump

Design: Premium design hard iron pumps for long wear life pumping severe slurries. The basic, single-wall construction and heavy section, hard metal wet end combined with the cartridge bearing assembly provides maximum reliability and ease of maintenance.

Applications: Pumps are widely used in ore transport, mill discharge, cyclone feed, tailings and plant process.

LSA-S

Q [m3/h] _____ max. 14000H [m] ___________ max. 90p [bar] __________ max. 16T [°C] ________ max. +120

Slurry pump

Design: The hydraulic wet end consists of three components: a shell or casing, an impeller and a suction plate/liner to permit easy removal for maintenance and inspections.

Applications: Reliable pumps for high discharge head, mildly corrosive slurries and a wide range of particle sizes. Used in mineral processing, mine dewatering, ash and tailings.

LCC-M

Q [m3/h] ______ max. 3865H [m] ___________ max. 90p [bar] __________ max. 16T [°C] ________ max. +120

Slurry pump

Page 39: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

39

Design: Interchangeable rubber and metal design allows best material choice for any application. Easy wet end change can adapt existing pumps to new applications.

Applications: Pumps are suitable for moderate discharge heads, fine particles and highly corrosive slurries.

LCC-R

Q [m3/h] ______ max. 3865H [m] ___________ max. 90p [bar] __________ max. 16T [°C] ________ max. +100

Slurry pump

S l u r r y p u m p s

Design: A high-pressure design, these pumps are constructed as horizontal, end suction centrifugal pumps to give maximum resistance to wear while simplifying maintenance. The conventional single-wall design transfers stress loads to non-wearing side plates in high-pressure applications.

Applications: Features high head and high flow rates for hydrotransport, tailings, dredging, pipeline booster stations and other severe duties.

TBC

Q [m3/h] _____ max. 18200H [m] ___________ max. 90p [bar] __________ max. 55T [°C] ________ max. +120

Slurry pump

Design: High-flow/low-head hard metal pumps with a single-wall shell design. High-efficiency impeller. Suction-side liner is equipped with integrated mounting plates.

Applications: Absorber recirculation and ancillary process pumps.

FGD

Q [m3/h] _____ max. 22700H [m] ___________ max. 45p [bar] __________ max. 17T [°C] ________ max. +120

Slurry pump

Design: Extra heavy-duty pumps with a high-grade rubber lining for hard wearing applications. The key to the LSR‘s success is its endurance.

Applications: Designed for heavy-duty mill circuit and fine grind slurries; specific-ally copper, iron ore, gold, aggregate and other abrasive applications.

LSR

Q [m3/h] ______ max. 9000H [m] ___________ max. 60p [bar] __________ max. 14T [°C] ________ max. +120

Slurry pump

Design: Vertical cantilever, rugged hard metal sump pump with bottom suction and no submerged bearings. Replaceable wet end parts in metal alloys with a durable mechanical end.

Applications: Ideal for industrial process pumping, tailings disposal in mining and pit use.

LCV

Q [m3/h] ______ max. 1360H [m] ___________ max. 38p [bar] __________ max. 14T [°C] ________ max. +120

Slurry pump

Page 40: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

40

S l u r r y p u m p s

Design: Horizontal, end suction, modified volute casing pump includes 3 vane open design impeller for large solids passage.

Applications: High-performance, low maintenance slurry pump recommended for coarse or fine particles from solids-laden waste water to aggressive slurries of an abrasive and/or corrosive nature.

Mega

Q [m3/h] ________ max. 45H [m] ___________ max. 30p [bar] __________ max. 24T [°C] ________ max. +120

Slurry pump

Design: Best suited for high-flow, high-head pumping where high production requires the reduction in the number of pumps.

Applications: Ideal for pipeline booster stations and severe mining duties. Also, as booster or main hull pump on cutter suction dredges.

HHD

Q [m3/h] _____ max. 14400H [m] ___________ max. 90p [bar] __________ max. 29T [°C] ________ max. +120

Slurry pump

Design: Designed to provide high flow/medium head with high efficiency for high volume transportation in long pipelines.

Applications: Ideal for pipeline booster stations and severe mining duties. Also for hopper dredges or as main pump on cutter dredges.

MHD

Q [m3/h] _____ max. 32000H [m] ___________ max. 80p [bar] __________ max. 28T [°C] ________ max. +120

Slurry pump

Design: High-flow/low-head design with balanced NPSHR and sphere passage for high volume transportation over short distance.

Applications: Ideal for sand & gravel, severe mining, dredge ladder and booster pumps.

LHD

Q [m3/h] _____ max. 21600H [m] ___________ max. 65p [bar] __________ max. 17T [°C] ________ max. +120

Slurry pump

Design: The latest technology from GIW provides superior wear life and increased up-time handling your most aggressive slurry applications.

Applications: Designed for SAG and ball mill discharge duties as well as cyclone feed and screen feed applications in ore mining.

MDX

Q [m3/h] _____ max. 14000H [m] ___________ max. 90p [bar] __________ max. 16T [°C] ________ max. +120

Slurry pump

Page 41: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

41

S l u r r y p u m p s

Design: Vertical cantilever, rugged hard metal sump pumps with top and bottom suction, not submerged bearings. Replaceable wet end parts in metal alloys with a durable mechanical end.

Applications: Abrasive slurries, dewatering, floor clean up, and process transfer.

ZW

Q [m3/h] _______ max. 400H [m] ___________ max. 35p [bar] __________ max. 10T [°C] ________ max. +120

Slurry pump

S e l f - p r i m i n g p u m p s

Design: Horizontal, long-coupled, self-priming volute casing pump in back pull-outdesign, single-stage, with open multi-vane impeller. ATEX-compliant version available.

Applications: Handling of pure, contaminated or aggressive liquids not containing abrasive substances and / or solids.

Etaprime L

DN _____________ 25 - 125Q [m3/h] _______ max. 180H [m] ___________ max. 85p [bar] __________ max. 10T [°C] _________ max. +90Data for 50 Hz operation

Self-priming pump for pure or contaminated liquids

Reference no. 2745.5-10 also available in 60 Hz

Design: Horizontal, self-priming volute casing pump, single-stage, with open multi-vane impeller, in close-coupled design, with common pump and motor shaft (B) orrigidly connected (BN). ATEX-compliant version available.

Applications: Handling of pure, contaminated or aggressive liquids not containing abrasive substances and / or solids.

Etaprime B / BN

DN _____________ 25 - 100Q [m3/h] _______ max. 130H [m] ___________ max. 72p [bar] __________ max. 10T [°C] _________ max. +90Data for 50 Hz operation

Reference no. 2746.5-10 also available in 60 Hz

Self-priming close-coupled pump for pure or contaminated liquids

Page 42: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

42

S u b m e r s i b l e b o r e h o l e p u m p s

Design: Multistage centrifugal pump in ring-section design, for vertical or horizontal installation, impellers made of plastic (S 100D) or stainless steel (UPA 100C) for well diameters of 100 mm (4 inches) and above, available with single-phase a.c. motor or three-phase motor with motor lead.

Applications: Domestic water supply, irrigation and spray irrigation systems, lower-ing of ground water levels, fire-fighting systems, cooling circuits, fountains, pressure boosting and air-conditioning systems.

S 100D / UPA 100C

DN _________________ 100Q [m3/h] ________ max. 16H [m] __________ max. 400T [°C] _________ max. +30Data for 50 Hz operation

Reference no. 3400.5-10 also available in 60 HzSwitchgears • Cervomatic

Submersible borehole pump

Design: Single-stage or multistage centrifugal pump in ring-section design, for vertical or horizontal installation, completely made of stainless steel, for well diam-eters of 150 mm (6 inches) and above.

Applications: Handling of clean or slightly contaminated water, irrigation and drainage, spray irrigation, industrial and municipal water supply, maintaining / lowering of groundwater levels, fire-fighting systems, drinking, raw and service water supply, pressure boosting.

UPA 150C

DN _________________ 150Q [m3/h] ________ max. 79H [m] __________ max. 570T [°C] _________ max. +50Data for 50 Hz operation

Reference no. 3400.52-10 also available in 60 HzHyamaster • PumpDrive

Submersible borehole pump

Design: Single- or multistage, single-entry centrifugal pump in ring-section design for vertical or horizontal installation. Non-return valve or connection branch on option. Mixed flow hydraulic systems available with reduced impeller diameters.

Applications: Handling of clean or slightly contaminated water in general water supply, irrigation and spray irrigation systems, maintaining / lowering of ground water levels, in mines, fire-fighting systems, fountains, etc.

UPA 300, 350

DN ____________ 300 - 350Q [m3/h] _______ max. 840H [m] __________ max. 480T [°C] _________ max. +50Data for 50 Hz operation

Reference no. 3400.5-10 also available in 60 HzHyamaster

Submersible borehole pump

Design: Single-stage or multistage single-entry centrifugal pump in ring-section design for vertical or horizontal installation. Available with non-return valve or con-nection branch.

Applications: Handling of clean or slightly contaminated water in general water supply, irrigation and spray irrigation systems, maintaining / lowering of ground water levels, fountains, pressure boosting systems, in mines, fire-fighting systems, emergency water supply systems, etc.

UPA 200, 200B, 250C

DN ____________ 200 - 250Q [m3/h] _______ max. 330H [m] __________ max. 460T [°C] _________ max. +50Data for 50 Hz operation

Reference no. 3400.5-10 also available in 60 HzHyamaster

Submersible borehole pump

Design: Single- or multistage, single-entry (BSX-BSF) or double-entry (UPZ) centrifugal pump in ring-section design for vertical or horizontal installation.

Applications: Handling of clean or slightly contaminated water, maintaining / lowering of ground water levels, in mines.

UPZ, BSX-BSF

DN _______________ > 350Q [m3/h] ______ max. 2200H [m] _________ max. 1500T [°C] _________ max. +50Data for 50 Hz operation

Reference no. 3470.021-10 also available in 60 Hz

Submersible borehole pump

Automation possible

Page 43: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

43

Design: Multistage, vertical high-pressure centrifugal pump in ring-section design with suction and discharge nozzles of identical nominal diameters arranged opposite to each other (in-line design), close-coupled and motor-mounted variable speed system.

Applications: Spray irrigation, irrigation, washing, water treatment, fire-fighting and pressure boosting systems, hot water and cooling water recirculation, boiler feed systems, etc.

Movitec PumpDrive

DN _____________ 25 - 100Q [m3/h] _______ max. 113H [m] __________ max. 401p [bar] __________ max. 40T [°C] ________ max. +140n [min-1] ______ max. 2900

Reference no. 1798.5-10 + 4070.5-10 also suitable for 60 Hz operation

High-pressure in-line pump with motor-mounted variable speed system

Design: Multistage horizontal or vertical centrifugal pump in ring-section design, long-coupled and close-coupled variant, with axial or radial suction nozzle, cast radial impellers. ATEX-compliant version available.

Applications: Water and drinking water supply systems, general industry, pressure boosting systems, irrigation systems, in power stations, heating, filter, fire-fighting, reverse osmosis and washing plants, snow guns, etc.

Multitec

DN _____________ 32 - 150Q [m3/h] _______ max. 850H [m] _____ max. 630 (800)p [bar] ______ max. 63 (80)T [°C] ______ -10 to +200n [min-1] ______ max. 4000Data for 50 Hz operation

Reference no. 1777.5-10 available in 50 Hz and 60 HzHyamaster

High-pressure pump in ring-section design

Design: Multistage horizontal or vertical centrifugal pump in ring-section design, long-coupled and close-coupled variant, with axial or radial suction nozzle, cast radial impellers and motor-mounted variable speed system.

Applications: Water and drinking water supply systems, general industry, pressure boosting systems, irrigation systems, in power stations, heating, filter, fire-fighting, reverse osmosis and washing plants, snow guns, etc.

Multitec PumpDrive

DN _____________ 32 - 125Q [m3/h] _______ max. 180H [m] __________ max. 630p [bar] __________ max. 63T [°C] ________ max. +110n [min-1] ______ max. 4000

Reference no. 1777.5-10 + 4070.5-10 also suitable for 60 Hz operation

High-pressure pump in ring-section design with motor-mounted variable speed system

Design: Multistage, vertical high-pressure centrifugal pump in ring-section designwith suction and discharge nozzles of identical nominal diameters arranged oppos-ite to each other (in-line design), close-coupled. ATEX-compliant version available.

Applications: Spray irrigation, irrigation, washing, water treatment, fire-fighting and pressure boosting systems, hot water and cooling water recirculation, boiler feed systems, etc.

Movitec V / LHS / VS / VC

DN _____________ 25 - 100Q [m3/h] _______ max. 113H [m] __________ max. 401p [bar] __________ max. 40T [°C] ________ max. +140n [min-1] ______ max. 2900Data for 50 Hz operation

Reference no. 1798.5-10 also available in 60 HzPumpMeter • Hyamaster

High-pressure in-line pump

H i g h - p r e s s u r e p u m p s , f i x e d / v a r i a b l e s p e e d

Automation possibleFactory-automated

PumpMeter

Page 44: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

44

A x i a l l y s p l i t p u m p s

Design: Single-stage, axially split volute casing pump for horizontal or vertical installation with double-entry radial impeller, mating flanges to DIN, ISO, BS or ANSI.

Applications: Handling of raw, pure and service water as well as seawater in water treatment plants, irrigation and drainage pumping stations, in power stations, fire-fighting systems, shipbuilding and the petrochemical industry.

RDLO

DN ____________ 350 - 700Q [m3/h] _____ max. 10000H [m] __________ max. 240p [bar] __________ max. 25T [°C] _________ max. +70n [min-1] ______ max. 1450Data for 50 Hz operation,higher values available upon request

Doku-Nr. 1385.51-10/1387.5 -10 also available in 60 HzHyamaster

Axially split volute casing pump DN 350 - 700

H y g i e n i c p u m p s f o r t h e f o o d , b e v e r a g e a n d p h a r m a c e u t i c a l

i n d u s t r i e s

Design: Maintenance-friendly annular casing pump, close-coupled with stand-ardised motor, all wetted components made of 316L stainless steel. Certified by the TNO Nutrition and Food Research Institute to EHEDG standards for processing food products.

Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-cal industries as well as in the chemical industry.

Vitachrom

DN _____________ 50 - 125Q [m3/h] _______ max. 340H [m] __________ max. 100p [bar] __________ max. 12T [°C] ________ max. +110Data for 50 Hz operation

Reference no. 1966.5-10 also available in 60 HzHyamaster • PumpDrive

Rolled steel centrifugal pump

Design: Single-stage, axially split volute casing pump for horizontal or vertical installation, with double-entry radial impeller, mating flanges to DIN, ISO, BS or ANSI.

Applications: Handling of raw, pure and service water as well as seawater in water treatment plants, irrigation and drainage pumping stations, power stations, fire-fighting systems, shipbuilding and the petrochemical industry.

Omega

DN _____________ 80 - 350Q [m3/h] ______ max. 2880H [m] __________ max. 170p [bar] __________ max. 25T [°C] _________ max. +70n [min-1] ______ max. 2900Data for 50 Hz operation,higher values available upon request

Reference no. 1384.5-10 also available in 60 HzHyamaster

Axially split volute casing pump DN 80 - 350

Automation possible

Design: Maintenance-friendly volute casing pump with standardised motor, all wetted components made of 316L stainless steel. Hygienic design for the highest requirements on cleanability (CIP/SIP-compatible), certified by the TNO Nutrition and Food Research Institute to EHEDG standards (Vitacast E).

Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-cal industries as well as in the chemical industry.

Vitacast / Vitacast E

DN _____________ 25 - 150Q [m3/h] _______ max. 560H [m] __________ max. 100p [bar] __________ max. 10T [°C] ________ max. +100Data for 50 Hz operation,other values available upon request

Reference no. 1969.51 / 1969.52 also available in 60 HzPumpDrive

Investment cast centrifugal pump

Page 45: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

45Automation possible

H y g i e n i c p u m p s f o r t h e f o o d , b e v e r a g e a n d p h a r m a c e u t i c a l

i n d u s t r i e s

Design: Maintenance-friendly, self-priming side channel pump in close-coupled design with standardised motor, all wetted components made of 316L stainless steel. Hygienic design for the highest requirements on cleanability (CIP/SIP-compatible).

Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-cal industries as well as in the chemical industry.

Vitaprime

DN ______________ 40 - 80Q [m3/h] ________ max. 55H [m] ___________ max. 43p [bar] ___________ max. 4T [°C] ________ max. +100Data for 50 Hz operation,other values available upon request

Reference no. 1969.54 also available in 60 Hz

Self-priming centrifugal pump

Design: Sturdy rotary lobe pump in hygienic design, bi-directional operation pos-sible, horizontal and vertical orientation of connections. Hygienic design, all wetted components made of 316L stainless steel; various rotor types and process connec-tions available. Pump set with geared motor.

Applications: Hygienic and gentle handling of sensitive or high-viscosity fluids in the food, beverage and pharmaceutical industries as well as in the chemical indus-try and general process engineering.

VitalobeDN ________ 25 - 200 (1“ - 8“)Q [m3/h] ____________ max. 300H [m] ______________ max. 200p [bar] ______________ max. 30T [°C] ___________ -40 to +200Viscosity [cP] ______ ≤ 3000000Volume displaced _____________ [litres per revolution] __ max. 10,5Data for 50 Hz operation,other values available upon request

Reference no. 1969.53 also available in 60 Hz

Rotary lobe pump

Design: Multistage centrifugal pump in close-coupled design for vertical or horizontal installation. All wetted components made of 316 stainless steel.

Applications: Processes in the food and beverage industry as well as in the chemical industry with moderate hygienic requirements.

Vitastage

Q [m3/h] ________ max. 40H [m] __________ max. 150p [bar] __________ max. 16T [°C] ________ max. +100Data for 50 Hz operation,other values available upon request

Reference no. 1969.55 also available in 60 Hz

Multistage centrifugal pump

PumpDrive

PumpDrive

P u m p s f o r p o w e r s t a t i o n c o n v e n t i o n a l i s l a n d s

Design: Horizontal, high-pressure barrel-type pump with radial impellers, single- and double-entry, multistage, with flanges / weld end nozzles to DIN and ANSI.

Applications: Handling of feed water and condensate in power stations and industrial facilities, generation of pressurized water for bark peeling machines and descaling equipment.

CHTA / CHTC / CHTD

DN ____________ 100 - 500Q [m3/h] ______ max. 3700H [m] _________ max. 5300p [bar] _________ max. 560T [°C] ________ max. +210n [min-1] ______ max. 6750Data for 50 Hz operation,higher values available upon request

Boiler feed pump

Reference no. 1860.1-10 also available in 60 Hz

Page 46: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

46

Design: Horizontal, radially split, product-lubricated, multistage ring-section pump with radial impellers, axial and radial single-entry inlet.

Applications: Handling of feed water in power stations, boiler feed water and condensate in industrial facilities.

HGM

DN _____________ 25 - 100Q [m3/h] _______ max. 274H [m] _________ max. 1400p [bar] _________ max. 140T [°C] ________ max. +160n [min-1] ______ max. 3600Data for 50 Hz operation,higher values available upon request

Boiler feed pump

Reference no. 1856.02-10 also available in 60 Hz

Design: Horizontal, radially split, single-stage, double-entry boiler feed booster pump (booster system) with single or double cast steel volute casing.

Applications: Handling of feed water in power stations and industrial facilities.

YNK / KRHA

DN ____________ 125 - 600Q [m3/h] ______ max. 3700H [m] __________ max. 280p [bar] __________ max. 40T [°C] ________ max. +210n [min-1] ______ max. 1800Data for 50 Hz operation,higher values available upon request

Boiler feed booster pump

Reference no. 1130.5-10 also available in 60 Hz

Design: Horizontal, radially split, multistage ring-section pump with radial impellers, single- or double-entry.

Applications: Handling of feed water and condensate in power stations and industrial facilities, generation of pressurized water for bark peeling machines, descaling equipment, snow guns, etc.

HGB / HGC / HGD

DN _____________ 40 - 400Q [m3/h] ______ max. 2300H [m] _________ max. 5300p [bar] _________ max. 560T [°C] ________ max. +210n [min-1] ______ max. 7000Data for 50 Hz operation,higher values available upon request

Boiler feed pump

Reference no. 1850.02-10 also available in 60 Hz

Design: Horizontal, high-pressure barrel-type pump with radial impellers, single- and double-entry, multistage, with flanges / weld end nozzles to DIN, API 610 and ANSI.

Applications: In refineries, in the petrochemical industry and in steam generation plants.

CHTR

DN ______________ 50 - 150 Q [m3/h] _______ max. 900H [m] _________ max. 2500p [bar] _________ max. 250T [°C] ________ max. +400n [min-1] ______ max. 7000Data for 50 Hz operation,higher values available upon request

Boiler feed pump

Reference no. 2701-10 also available in 60 Hz

P u m p s f o r p o w e r s t a t i o n c o n v e n t i o n a l i s l a n d s

Design: Horizontal, single-stage, double-entry feed water pump, cast and forged variant.

Applications: Handling of feed water in steam generation systems of nuclear power stations.

RHD

DN ____________ 250 - 400Q [m3/h] ______ max. 6500H [m] _________ max. 1000p [bar] _________ max. 150T [°C] ________ max. +210n [min-1] ______ max. 6500Data for 50 Hz operation,higher values available upon request

Feed water pump

also available in 60 Hz

Page 47: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

47

P u m p s f o r p o w e r s t a t i o n c o n v e n t i o n a l i s l a n d s

Design: Vertical spherical casing pump, radial impellers, single-entry, single- to three-stage. Suitable for very high inlet pressures and temperatures. Integrated wet winding motor to VDE. Product-lubricated bearings, no need for oil supply systems. Design to TRD or ASME.

Applications: Hot water recirculation in forced-circulation, forced-flow and combined-circulation boilers for very high pressures.

LUV / LUVA

DN ____________ 100 - 550Q [m3/h] ______ max. 7000H [m] __________ max. 275p [bar] _________ max. 320T [°C] ________ max. +420n [min-1] ______ max. 3600Data for 50 Hz operation,higher values available upon request

Boiler recirculation pump

Reference no. 0361.033-10 also available in 60 Hz

Design: Vertical, multistage, can-type ring-section pump with radial and mixed flow impellers. Single- and double-entry suction impellers, flanges to DIN or ANSI. The can is arranged in a pit below the installation floor. The pump is connected with the structure by means of a baseplate.

Applications: Handling of condensate in power stations and energy systems.

WKT / WKTA / WKTB

DN _____________ 40 - 300Q [m3/h] ______ max. 1800H [m] __________ max. 340p [bar] __________ max. 40T [°C] ________ max. +100n [min-1] ______ max. 1800Data for 50 Hz operation,higher values available upon request

Condensate pump

Reference no. 0361.033-10 also available in 60 Hz

Design: Vertical tubular casing pump with open mixed flow impeller (SEZ), mixed flow propeller (PHZ) or axial propeller (PNZ). Pump inlet with bellmouth or suction elbow, pull-out design available, discharge nozzle arranged above or below floor, flanges to DIN or ANSI standards available.

Applications: Handling of raw, pure, service and cooling water in industry, water supply systems, in power stations and seawater desalination plants.

SEZ / SEZT / PHZ / PNZ

Q [m3/s] ________ max. 22H [m] __________ max. 100T [°C] _________ max. +40n [min-1] _______ max. 980Data for 50 Hz operation,higher values available upon request

Cooling water pump

Reference no. 1471.02-10 also available in 60 Hz

Design: Vertical tubular casing pump with mixed flow impeller (SNW) or axial propeller (PNW), single-stage, with maintenance-free Residur shaft bearings, discharge nozzle arranged above or below floor.

Applications: Irrigation and drainage systems, stormwater pumping stations, hand ling of raw and pure water, water supply systems, handling of cooling water.

SNW / PNW

DN ____________ 350 - 800Q [m3/h] ______ max. 9000H [m] ___________ max. 50p [bar] __________ max. 10T [°C] _________ max. +60n [min-1] ______ max. 1500Data for 50 Hz operation,higher values available upon request

Cooling water pump

Reference no. 1481.5-10/1591.5-10 also available in 60 Hz

Design: Long-coupled, single-stage volute casing pump in back pull-out design.

Applications: Drainage, irrigation and water supply systems, handling of conden-sate, cooling water, service water, etc.

SPY

DN __________ 350 - 1200Q [m3/h] _____ max. 21600H [m] ___________ max. 50p [bar] __________ max. 10T [°C] ________ max. +105n [min-1] ______ max. 1480Data for 50 Hz operation,higher values available upon request

Cooling water pump

Reference no. 2384.51-10 also available in 60 Hz

Page 48: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

48

P u m p s f o r p o w e r s t a t i o n n u c l e a r i s l a n d s

Design: Vertical, single-stage reactor coolant pump with forged annular casing plated on the inside, with diffuser, either with own pump thrust bearing or supported by motor bearing.

Applications: Reactor coolant recirculation in nuclear power stations (PWR).

RER

DN ____________ max. 800Q [m3/h] _____ max. 40000H [m] __________ max. 140p [bar] _________ max. 175T [°C] ________ max. +350n [min-1] ______ max. 1800Data for 50 Hz operation,higher values available upon request

Reactor coolant pump

also available in 60 Hz

Design: Vertical, single-stage reactor coolant pump, with cast double volute casing, supported by motor bearing.

Applications: Reactor coolant recirculation in nuclear power stations (PWR, PHWR).

RSR

DN ____________ max. 600Q [m3/h] ______ max. 9000H [m] __________ max. 215p [bar] _________ max. 125T [°C] ________ max. +310n [min-1] _______ max. 1800Data for 50 Hz operation,higher values available upon request

Reactor coolant pump

Design: Vertical pump set integrated in the reactor pressure vessel, glandless pump with leak-free, low-maintenance wet winding motor.

Applications: Reactor coolant recirculation in boiling water reactors (BWR).

PSR

DN ____________ max. 600Q [m3/h] ______ max. 9000H [m] ___________ max. 45p [bar] __________ max. 75T [°C] ________ max. +300n [min-1] ______ max. 2000Data for 50 Hz operation,higher values available upon request

Reactor internal pump

also available in 60 Hz

Design: Vertical pump with integrated motor, single-entry, one to three stages. Suitable for very high inlet pressures and temperatures. Integrated wet winding motor to VDE. Product-lubricated bearings, no need for oil supply systems. Design to ASME Section 3, KTA, etc.

Applications: As reactor water clean-up pump in boiling water reactors, reactor coolant pump in boiling water and pressurized water reactors, and as recirculation pump in test facilities.

LUV - Nuclear

DN _____________ 40 - 600Q [m3/h] ______ max. 7000H [m] __________ max. 300p [bar] _________ max. 320T [°C] ________ max. +430Data for 50 Hz operation,higher values available upon request

Reactor coolant / reactor water clean-up pump

also available in 60 Hz

Design: Horizontal, multistage barrel pull-out pump.

Applications: Core flooding, emergency cooling and residual heat removal systems, volume control systems, high-pressure charging, control rod drive systems, high- and medium-pressure safety injection systems, auxiliary feed water systems, start-up and shutdown feed water systems.

RHM

DN ____________ max. 150Q [m3/h] _______ max. 300H [m] _________ max. 2100p [bar] _________ max. 220T [°C] ________ max. +180n [min-1] ______ max. 8000Data for 50 Hz operation,higher values available upon request

Pump for safety-related and auxiliary systems

also available in 60 Hz

Page 49: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

49

Design: Vertical, multistage barrel pull-out pump.

Applications: Core flooding, emergency cooling and residual heat removal systems, volume control systems, high-pressure safety injection systems.

RVM

DN _____________ max. 85Q [m3/h] ________ max. 50H [m] _________ max. 2000p [bar] _________ max. 200T [°C] ________ max. +100n [min-1] ______ max. 6000Data for 50 Hz operation,higher values available upon request

Pump for safety-related and auxiliary systems

also available in 60 Hz

Design: Horizontal or vertical annular casing pump with forged pressure boundary and diffuser.

Applications: Core flooding, emergency cooling and residual heat removal systems, ancillary systems, acid feed systems and low- pressure feed systems.

RHR / RVR

DN ____________ max. 500Q [m3/h] ______ max. 6000H [m] __________ max. 190p [bar] __________ max. 63T [°C] ________ max. +200n [min-1] ______ max. 3600Data for 50 Hz operation

Pump for safety-related and auxiliary systems

also available in 60 Hz

P u m p s f o r p o w e r s t a t i o n n u c l e a r i s l a n d s

Design: Vertical, single-stage reactor coolant pump. Seal-less design with inte-grated wet winding motor and integrated flywheel. Product-lubricated bearings, no oil supply systems required.

Applications: Main coolant circulation in third-generation nuclear power stations.

RUV

DN ____________ max. 710Q [m3/h] _____ max. 22000H [m] __________ max. 111p [bar] _________ max. 155T [°C] ________ max. +350n [min-1] ______ max. 1800higher values available upon request

Reactor coolant pump

available in 50 Hz and 60 Hz

Page 50: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

50

P u m p s a n d p r e s s u r e e x c h a n g e r s f o r s e a w a t e r d e s a l i n a t i o n

b y r e v e r s e o s m s i s

Description: Pressure exchanger specially developed for use in RO seawater desalination systems, in duplex stainless steel (standard) or super duplex stainless steel (on request).

SalTec DT

Q [m3/h] _______ max. 280p [bar] __________ max. 80T [°C] _________ max. +40

Pressure exchanger

Reference no. 1858.1-10

Design: Hydraulic system for pressure boosting and energy recovery in reverse osmosis processes for seawater desalination.

Components: SalTec® DT pressure exchanger, HGM-RO high-pressure pump, RPH-RO booster pump and control unit.

Applications: Seawater desalination by reverse osmosis.

SalTec System

Q [m3/day] ______ ≥ 10000p [bar] __________ max. 80T [°C] _________ max. +40

Hydraulic system

Reference no. 1858.11-10

Design: Horizontal, radially-split, product-lubricated, multistage ring-section pump with radial impellers and plain bearings. Axial and radial single-entry inlet. Duplex stainless steel variant also suitable for chilled water applications.

Applications: High-pressure pump for RO seawater desalination systems.

HGM-RO

DN _____________ 65 - 250 Q [m3/h] ______ max. 1500H [m] __________ max. 950p [bar] _________ max. 120T [°C] _________ max. +40n [min-1] ______ max. 3600Data for 50 Hz operation, higher values available upon request

High-pressure pump

Reference no. 1582.12-10 also available in 60 Hz

Design: Horizontal, multistage pump in ring-section design. Axial suction nozzle, discharge nozzle can be turned in steps of 90°. Closed radial impellers. In duplex or super-duplex stainless steel.

Applications: High-pressure pump for RO seawater desalination systems.

Multitec-RO

DN _____________ 50 - 150Q [m3/h] _______ max. 850H [m] _________ max. 1000p [bar] _________ max. 100T [°C] _________ max. +40n [min-1] _______ max. 4000Data for 50 Hz operation

High-pressure pump

Reference no. 1777.13-10 available in 50 Hz and 60 Hz

Design: Horizontal, radially split volute casing pump, dry-installed, made of duplex stainless steel (standard) or super duplex stainless steel (on request).

Applications: Booster pump for RO seawater desalination systems.

RPH-RO

DN _____________ 25 - 400Q [m3/h] ______ max. 4150H [m] __________ max. 270p [bar] _________ max. 104T [°C] _________ max. +50Data for 50 Hz operation

Booster pump

also available in 60 Hz

Automation possibleFactory-automated

Hyamaster • PumpDrive

Page 51: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

51

C o n t r o l u n i t s

Design: Single-pump control system for starting, stopping and monitoring pumps.

Applications: Water supply systems, in combination with pumps like Multi Eco, Multichrom S, Ixo, S 100D, etc.

Controlmatic E.2

No. of pumps _____ max. 1 Voltage [V] _______ 1∼230

Reference no. 5125.1785-10

Automatic control unit

Design: Single-pump control unit for pressure-controlled starting and either pressure-controlled or flow-controlled stopping as well as monitoring pumps.

Applications: In water supply systems using, for example, Multi Eco, Ixo, S 100D and UPA 150C.

Cervomatic EDP.2

No. of pumps _____ max. 1 Voltage [V] __ 1∼230 / 3∼400

Reference no. 5125.178-10

Automatic control unit

Design: Level control unit for controlling up to two pumps. Direct starting up to 4 kW, star-delta starting up to 22 kW.

Applications: Tank drainage via float switches, pneumatic or bubbler control in building services and waste water applications.

LevelControl

No. of pumps ____ max. 2[kW] ___________ max. 22Voltage [V] _____ 230 / 400higher values available upon request

Reference no. 4040.5-10, 4041.5-10

Level control unit

Design: Single-pump control unit for submersible borehole pumps, submersible motor pumps and dry-installed pumps.

Applications: Water supply systems, in combination with pumps like S 100D, UPA 150S, etc.

UPA Control

No. of pumps _____ max. 1 [kW] _________________ 3Voltage [V] _ 1∼230 / 3∼400

Reference no. 3465.1-10

Control system for submersible borehole pumps

Design: Pump control system in control cabinet for cascade starting and stopping of up to 6 pumps on the mains.

Applications: Water supply systems.

hyatronic N

No. of pumps _____ max. 6 [kW] ________________ 22Voltage [V] _______ 3∼400

Reference no. 0543.5026-10

Pump control system for cascade starting and stopping

Page 52: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

52

Design: Pump control system in control cabinet for asynchronous motors of all types and makes for controlling and monitoring hydraulic systems.

Applications: Heating, ventilation and air-conditioning systems, water supply and drainage systems.

hyatronic mb

No. of pumps _____ max. 8 FI _______________ max. 2[kW] _______________ 200Voltage [V] _______ 3∼400

Reference no. 0974.5-10

Pump control system for continuously variable speed adjustment

Design: Control system for pumps with three-phase motors of all types and makes, consisting of a KSB controller with display and control panel and all required power components.

Applications: Industrial and process engineering circuits, service water supply, cooling and lubrication, energy supply in cogeneration plants, heat transfer and district heating stations, water extraction and treatment, water supply and waste water disposal.

Hyamaster ISB

No. of pumps _____ max. 8 FI _______________ max. 2[kW] _______________ 200Voltage [V] _______ 3∼400

Reference no. 1961.5-10

Pump control system for continuously variable speed adjustment

S p e e d c o n t r o l

Design: Self-cooling frequency inverter which allows the motor speed to be varied continuously by means of standard signals and a field bus. Because PumpDrive is self-cooling, it can be mounted on the motor, on the wall or in a cabinet. Control of up to 6 pumps without an additional controller (with PumpDrive Advanced).

Applications: Cooling circuits, filters, water supply systems, heating, ventilation and air-conditioning systems, spray irrigation systems, boiler feed systems, steam generation plants, process engineering circuits, cooling lubricant supply systems, service water supply systems and other process engineering applications.

PumpDrive

No. of pumps _____ max. 6 FI _____ 1 per pump/motor[kW] ________________ 45Voltage [V] __ 3∼380 to 480

Reference no. 4070.5-10

Self-cooling, motor-independent variable-speed system

Design: Single-pump control system for continuously variable speed adjustment with integrated frequency inverter.

Applications: Heating, ventilation, air-conditioning, water supply and drainage systems.

hyatronic spc

No. of pumps _____ max. 1FI _______________ max. 1[kW] _______________ 7.5Voltage [V] _______ 3∼400

Reference no. 0973.5-10

Pump control system for continuously variable speed adjustment

Design: Control system for pumps with three-phase motors of all types and makes, consisting of a programmable logic controller (PLC) with display and control panel and all required power components housed in a control cabinet.

Applications: Process engineering circuits, service water supply, cooling and lubrication systems, cogeneration plants, heat transfer and district heating stations, water extraction and treatment, water supply and waste water disposal.

Hyamaster SPS

No. of pumps _____ max. 4 FI ___________ 1 per pump[kW] _______________ 650Voltage [V] _______ 3∼400

Reference no. 1964.5-10

Pump control system for continuously variable speed adjustment

Page 53: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

53

M o n i t o r i n g a n d d i a g n o s t i c s y s t e m s

Design: Monitoring system for submersible waste water pumps with shutdown.

Amacontrol

No. of pumps _____ max. 1 Type ___________ AmacanInstallation _____ mounting ____________ plate IP20Voltage ________ 230 V AC

Reference no. 2316.178-10

Monitoring system for submersible waste water pumps

Design: The PumpMeter device is an intelligent pressure transmitter for pumps, with on-site display of measured values and operating data. The device consists of two pressure sensors and a display unit. It records the load profile of the pump in order to indicate any potential for optimising energy efficiency and availability.

Applications: For monitoring the operation of a centrifugal pump.

PumpMeter

No. of pumps _____ max. 1 Type see pump type seriesInstallation ______ factory- ________ mounted, IP 65 Voltage _________ 24 V DC

Reference no. 4072.5-10

Intelligent pressure transmitter

Page 54: Pumps and Automation 2011 - Bombas · PDF fileType series index for pumps and automation HGB / HGC / HGD 46 HGM 46 ... API series (Nikkiso-KSB) ... Mega 40 n HHD 40 n MHD 40 n LHD

0506

.02/

17-1

0 /

01

.11

/

© K

SB A

ktie

ng

esel

lsch

aft

2011

Sub

ject

to

tec

hn

ical

mo

dif

icat

ion

wit

ho

ut

pri

or

no

tice

.

KSB AktiengesellschaftJohann-Klein-Straße 967227 Frankenthal (Germany) www.ksb.com

More space for solutions.

Your local KSB representative:


Recommended