+ All Categories
Home > Documents > Pumps ı Automation - ksb.com · RPH 39 RPH-LF 39 RPHb / RPHd 39 RPH-V 39 CTN 39 CHTR 40 CHTRa 40...

Pumps ı Automation - ksb.com · RPH 39 RPH-LF 39 RPHb / RPHd 39 RPH-V 39 CTN 39 CHTR 40 CHTRa 40...

Date post: 29-Aug-2019
Category:
Upload: hadien
View: 230 times
Download: 0 times
Share this document with a friend
76
Our technology. Your success. Pumps Valves Service Product Portfolio 2019 Pumps ı Automation
Transcript

Our technology. Your success.Pumps ■ Valves ■ Service

Product Portfolio 2019

Pumps ı Automation

  Type Series Index

  Type Series Index  

2

Type Series IndexAmacan K 52Amacan P 52Amacan S 53Amaclean 49Amacontrol 73Ama-Drainer 4../5.. 48Ama-Drainer 80, 100 48Ama-Drainer N 48Ama-Drainer-Box 49Ama-Drainer-Box Mini 49AmaDS³ 49Amajet 54Amaline 54Amamix 54Ama-Porter CK Pump Station 51Ama-Porter F / S 48Amaprop 54Amarex KRT 52Amarex N 52AU 59AU Monobloc 59

B Pump 61Beveron 67

Calio 31Calio S 30Calio Z 31Calio-Therm NC 30Calio-Therm S 30Calio-Therm S NC/NCV 30Cervomatic EDP.2 72CHTA / CHTC / CHTD 65CHTR 40CHTRa 40CINCP / CINCN 40CK 800 Pump Station 50CK 1000 Pump Station 50Comeo 62Compacta 50Controlmatic E 72Controlmatic E.2 72CPKN 37CTN 39

DU / EU 71

EDS 70Emporia CP 42Emporia MB 42Emporia PD 42Estigia 40Etabloc 33Etabloc SYT 36Etachrom B 34Etachrom L 34Etaline 32Etaline DL 31Etaline L 31Etaline SYT 36Etaline Z 32Etaline-R 32Etanorm 33Etanorm SYT / RSY 36Etanorm V 34Etanorm-R 33Etaprime B 59Etaprime L 59Etaseco / Etaseco-I 38Etaseco RVP 38Evamatic-Box N 50EZ B/L 59

FGD 57Filtra N 44

HGB / HGC / HGD 65HGI 66HGM 66HGM-RO 70HPH 35HPK 35HPK-L 35

HVF 58Hya-Duo D FL 45Hya-Duo D FL Compact 46Hyamat K 46Hyamat SVP 46Hyamat SVP ECO 47Hyamat V 46Hya-Rain / Hya-Rain N 42Hya-Rain Eco 42Hya-Solo D 45Hya-Solo D FL 45Hya-Solo D FL Compact 46Hya-Solo DSV 45Hyatronic N 73

ILN 32ILNC 32INVCP 40Ixo N 43Ixo-Pro 43

KSB Delta Compact MVP 44KSB Delta Eco MVP/SVP 44KSB Delta Primo K/VP/SVP 44KSB Delta Solo MVP/SVP 45KSB Guard 29KSB SuPremE 28KSB UMA-S 28KWP 55KWP-Bloc 55

LCC-M 56LCC-R 56LCV 57LevelControl Basic 2 72LHD 57LSA-S 56LUV / LUVA 66LUV Nuclear 68

Magnochem 38Magnochem 685 38Magnochem-Bloc 38MDX 57Megabloc 35MegaCPK 36Megaline 33Meganorm 34MHD 57mini-Compacta 50MK / MKY 49Movitec 62Movitec H(S)I 62Movitec VCI 62Multi Eco 43Multi Eco-Pro 43Multi Eco-Top 43Multitec 63Multitec-RO 70

Omega 63

PSR 68PumpDrive 2 / PumpDrive 2 Eco 28PumpDrive R 28PumpMeter 29

RC / RCV 70RDLO 63RDLP 63RER 67RHD 68RHM 69RHR 69Rotex 48RPH 39RPHb / RPHd 39RPH-LF 39RPH-RO 69RPH-V 39RSR 68RUV 68RVM 69

RVR 69RWCP / RWCN 41

Sewabloc 55Sewatec 55Sewatec SPN 55SEZ / SEZT / PHZ / PNZ 67SNW / PNW 67SPY 67SRL 51SRP 51SRS 51Surpress Feu SFE 47Surpresschrom SIC.2 47Surpresschrom SIC.2 SVP 47Surpresschrom SIC.2 V 47

TBC 56

UPA 150C 60UPA 200, 200B, 250C 60UPA 300, 350 60UPA Control 72UPAchrom 100 CC 60UPAchrom 100 CN 60UPA-Z / UPA-R 61

Vitacast 64Vitacast Bloc 64Vitachrom 64Vitalobe 65Vitaprime 64Vitastage 65

WBC 56WKTB 66WKTR 41

YNK 66

ZW 58

  Introduction

  Introduction  

3

Our tradition:Competence since 1871

We have supplied generations of customers worldwide with pumps, valves, automation products and services. A company with that kind of experience knows that success is a process based on a stream of innovations. A process made possible by a close working alliance between developer and user, between production and practice.

Partners achieve more together.

We do everything possible to ensure that our customers

always have access to the ideal product and system solution.

KSB is a loyal partner. And a strong one:

■■ Over 140 years’ experience

■■ Present in more than 100 countries

■■ More than 16,000 employees

■■ More than 170 service centres worldwide

■■ Approximately 3,000 service specialists

  Introduction

  Introduction  

4

Single-source supplier: your partner for pumps, valves and service

A comprehensive product range, short response times and tailored service and spare parts solutions – no other competitor offers a comparable range of products and services. In all phases of the product life cycle, we are on hand to ensure that our customers secure long-term value from their systems. We offer our customers a variety of services and spare parts solutions around pumps, valves, and other rotating equipment – also for non-KSB products:

■■ Technical consultancy■■ Installation and commissioning■■ Services provided on-site and in

our service centres■■ Inspection and maintenance■■ Maintenance inspection management■■ Framework agreements such as

TPM® Total Pump Management■■ Reverse engineering

■■ Ef�ciency analysis with SES System

Ef�ciency Service or Pump Operation Check■■ Retro�tting as an alternative to buying a

new product■■ Spare parts in manufacturer’s quality■■ On-site training sessions■■ Refurbishment and decommissioning■■ Inventory management

Ready wherever you are: with a global service network and a 24-hour emergency service.

  Introduction

  Introduction  

5

Our mission: Certified quality assurance

Our five key goals:

■■ Maximum customer satisfaction: We do everything to fulfil

our customers’ wishes on time and in full.

■■ Fostering quality awareness: We put our quality commitment

into daily practice – from executives to employees,

whose qualifications and competence we foster through

continuing training.

■■ Prevention rather than cure: We systematically analyse errors

and prevent the causes.

■■ Improvement in quality: We continually optimise our

processes in order to work more efficiently.

■■ Involvement of suppliers: We attach great importance

to working together fairly and openly to achieve our

shared goals.

First-class products and excellent service take top priority at KSB.

To maintain this level of excellence, we have developed a modern

quality management system with globally applicable guidelines.

It is based on the Business Excellence model of the European

Foundation for Quality Management, which already ensures

improved quality management Europewide.

Our guidelines define uniform quality for all KSB locations and

have helped us to optimise our manufacturing processes.

The results are shorter delivery times and global availability

of our products. These guidelines govern the way we act so

comprehensively that even the competence of our consulting

and the good value for money we offer are clearly stipulated.

Like the ‘Made in Germany’ quality seal, we introduced internal

certification as a sign of the highest quality: ‘Made by KSB’.

As a signatory to the United Nations Global Compact, KSB is committed to

endorsing the ten principles of the international community in the areas

of human rights, labour standards, environmental protection and anti-

corruption.

  Introduction

  Introduction  

6

Our technology. Your success. Pumps n Valves n Service

Industry 4.0: we have experience with the future

Digital networking of production systems is one of the key challenges ahead. An expert in engineering with long-standing experience in developing Industry 4.0 solutions, KSB is your ideal partner to achieve:

■n Resource efficiency and optimised use of materials■n Availability and operating reliability■n Flexibility through short-term reconfigurability■n Reduction of time to market

Increase your system’s productivity already today with KSB’s smart products and services: Use our intelligent technologies designed to communicate, such as PumpDrive and PumpMeter, to lay a foundation for your smart factory. Find out more about our future-driven solutions at www.ksb.com/industry40

  Introduction

  Introduction  

7

System analysis Creating transparency Determining the

load profile

Selection

Defining the system structure Selecting components

Commissioning

Expert installation Professional commissioning

Highly efficient operation

Intelligent pump technology

Continuous monitoring

ENERGY-EFFICIENT PRODUCTS AND SERVICES

The process and its four steps are clearly

defined – based on extensive expertise and

experience. This systematic and targeted

approach ensures maximum savings at

minimum costs. Perfectly matching the

hydraulic system, drive and automation

products as well as the piping dimensions

can result in savings of up to 60 %.

We reduce the operating costs of your

system by combining our expert know-

ledge with smart products and services.

This is our joint contribution towards

an energy-efficient future.

More on FluidFuture®:

www.ksb.com/fluidfuture

FluidFuture®: the energy-saving concept for your system

Many systems do run reliably but they also use a lot more power than necessary. The solution: efficiency optimisation with FluidFuture® in four steps. We look at the entire hydraulic system to achieve maximum energy efficiency throughout the life cycle. The optimisation costs will pay for themselves within a short period through the high energy savings that can be made.

  General Information

  General Information  

8

General Information

ErP

ErP regulations stipulating new, stricter minimum efficiency values becameeffective at the start of 2015. Since then, only pumps and motors which satisfythe energy efficiency requirements of the European Union's ErP Directive maybe placed on the market. For KSB's products this is child's play. They are soefficient, many actually exceed the values required since 2015 – some eventhose applicable from 2017 as per the ErP regulations.

Regional products Not all depicted products are available for sale in every country. Products onlyavailable in individual regions are indicated accordingly. Please contact yoursales representative for details.

Trademark rights All trademarks or company logos shown in the catalogue are protected bytrademark rights owned by KSB SE & Co. KGaA and/or a KSB Group company.The absence of the "®" symbol should not be interpreted to mean that theterm is not a registered trademark.

Product illustrations The products illustrated as examples may include options and accessoriesincurring a surcharge. Subject to modifications due to technical enhancements.

  Product Portfolio

  Product Portfolio  

9

Pumps

Design / Application Type series Page ErP

Fact

ory

-au

tom

ated

Au

tom

atio

nav

aila

ble

Wat

er T

ran

spo

rtan

d T

reat

men

t

Ind

ust

ry

Ener

gy

Co

nve

rsio

n

Bu

ildin

gSe

rvic

es

Solid

s Tr

ansp

ort

Drinking water circulators, fixed speedCalio-Therm S NC/NCV 30

Calio-Therm NC 30

Drinking water circulators, variable speed Calio-Therm S 30

Circulators, variable speed

Calio S 30

Calio 31

Calio Z 31

In-line pumps

Etaline L 31

Etaline DL 31

Etaline 32

Etaline Z 32

Etaline-R 32

ILN 32

ILNC 32

Megaline 33

Standardised / close-coupled pumps

Etanorm 33

Etanorm-R 33

Etabloc 33

Etachrom B 34

Etachrom L 34

Etanorm V 34

Meganorm 34

Megabloc 35

Hot water pumps

HPK-L 35

HPH 35

HPK 35

Hot water / thermal oil pumps

Etanorm SYT / RSY 36

Etabloc SYT 36

Etaline SYT 36

Standardised chemical pumpsMegaCPK 36

CPKN 37

Seal-less pumps

Magnochem 38

Magnochem 685 38

Magnochem-Bloc 38

Etaseco / Etaseco-I 38

Etaseco RVP 38

Process pumps

RPH 39

RPH-LF 39

RPHb / RPHd 39

RPH-V 39

CTN 39

CHTR 40

CHTRa 40

CINCP / CINCN 40

INVCP 40

Estigia 40

RWCP / RWCN 41

WKTR 41

Rainwater harvesting systemsHya-Rain / Hya-Rain N 42

Hya-Rain Eco 42

  Product Portfolio

  Product Portfolio  

10

Design / Application Type series Page ErP

Fact

ory

-au

tom

ated

Au

tom

atio

nav

aila

ble

Wat

er T

ran

spo

rtan

d T

reat

men

t

Ind

ust

ry

Ener

gy

Co

nve

rsio

n

Bu

ildin

gSe

rvic

es

Solid

s Tr

ansp

ort

Domestic water supply systems with automaticcontrol unit / Swimming pool pumps

Emporia CP 42

Emporia MB 42

Emporia PD 42

Multi Eco 43

Multi Eco-Pro 43

Multi Eco-Top 43

Ixo N 43

Ixo-Pro 43

Filtra N 44

Pressure booster systems

KSB Delta Compact MVP 44

KSB Delta Eco MVP/SVP 44

KSB Delta Primo K/VP/SVP 44

KSB Delta Solo MVP/SVP 45

Hya-Solo D 45

Hya-Solo DSV 45

Hya-Solo D FL 45

Hya-Duo D FL 45

Hya-Solo D FL Compact 46

Hya-Duo D FL Compact 46

Hyamat K 46

Hyamat V 46

Hyamat SVP 46

Hyamat SVP ECO 47

Surpresschrom SIC.2 47

Surpresschrom SIC.2 V 47

Surpresschrom SIC.2 SVP 47

Surpress Feu SFE 47

Drainage pumps / waste water pumps

Ama-Drainer N 48

Ama-Drainer 4.. / 5.. 48

Ama-Drainer 80, 100 48

Ama-Porter F / S 48

Rotex 48

MK / MKY 49

Lifting units / package pump stations

Amaclean 49

AmaDS3 49

Ama-Drainer-Box Mini 49

Ama-Drainer-Box 49

Evamatic-Box N 50

mini-Compacta 50

Compacta 50

CK 800 Pump Station 50

CK 1000 Pump Station 50

Ama-Porter CK Pump Station 51

SRP 51

SRL 51

SRS 51

Submersible motor pumpsAmarex N 52

Amarex KRT 52

Submersible pumps in discharge tubes

Amacan K 52

Amacan P 52

Amacan S 53

Mixers / agitators / tank cleaning units

Amamix 54

Amaprop 54

Amajet 54

Amaline 54

  Product Portfolio

  Product Portfolio  

11

Design / Application Type series Page ErP

Fact

ory

-au

tom

ated

Au

tom

atio

nav

aila

ble

Wat

er T

ran

spo

rtan

d T

reat

men

t

Ind

ust

ry

Ener

gy

Co

nve

rsio

n

Bu

ildin

gSe

rvic

es

Solid

s Tr

ansp

ort

Pumps for solids-laden fluids

Sewatec 55

Sewatec SPN 55

Sewabloc 55

KWP 55

KWP-Bloc 55

Slurry pumps

WBC 56

LSA-S 56

LCC-M 56

LCC-R 56

TBC 56

LCV 57

FGD 57

MHD 57

LHD 57

MDX 57

ZW 58

HVF 58

Self-priming pumps

Etaprime L 59

Etaprime B 59

EZ B/L 59

AU 59

AU Monobloc 59

Submersible borehole pumps

UPAchrom 100 CC 60

UPAchrom 100 CN 60

UPA 150C 60

UPA 200, 200B, 250C 60

UPA 300, 350 60

UPA-Z / UPA-R 61

Vertical turbine pumps B Pump 61

High-pressure pumps

Comeo 62

Movitec H(S)I 62

Movitec 62

Movitec VCI 62

Multitec 63

Axially split pumps

Omega 63

RDLO 63

RDLP 63

Hygienic pumps for the food, beverage andpharmaceutical industries

Vitachrom 64

Vitacast 64

Vitacast Bloc 64

Vitaprime 64

Vitastage 65

Vitalobe 65

Pumps for power station conventional islands

CHTA / CHTC / CHTD 65

HGB / HGC / HGD 65

HGI 66

HGM 66

YNK 66

LUV / LUVA 66

WKTB 66

SEZ / SEZT / PHZ / PNZ 67

SNW / PNW 67

Beveron 67

SPY 67

  Product Portfolio

  Product Portfolio  

12

Design / Application Type series Page ErP

Fact

ory

-au

tom

ated

Au

tom

atio

nav

aila

ble

Wat

er T

ran

spo

rtan

d T

reat

men

t

Ind

ust

ry

Ener

gy

Co

nve

rsio

n

Bu

ildin

gSe

rvic

es

Solid

s Tr

ansp

ort

Pumps for nuclear power stations

RER 67

RSR 68

RUV 68

PSR 68

RHD 68

LUV Nuclear 68

RHM 69

RVM 69

RHR 69

RVR 69

Pumps for desalination by reverse osmosis

RPH-RO 69

HGM-RO 70

Multitec-RO 70

Positive displacement pumps RC / RCV 70

Fire-fighting systemsEDS 70

DU / EU 71

  Product Portfolio

  Product Portfolio  

13

Automation and drives

Design / Application Type series Page ErP

Wat

er T

ran

spo

rt a

nd

Trea

tmen

t

Ind

ust

ry

Ener

gy

Co

nve

rsio

n

Bu

ildin

g S

ervi

ces

Solid

s Tr

ansp

ort

Automation and drivesKSB SuPremE 28

KSB UMA-S 28

Control units

Controlmatic E 72

Controlmatic E.2 72

Cervomatic EDP.2 72

LevelControl Basic 2 72

UPA Control 72

Hyatronic N 73

Variable speed systemsPumpDrive 2 / PumpDrive 2 Eco 28

PumpDrive R 28

Monitoring and diagnosis

PumpMeter 29

KSB Guard 29

Amacontrol 73

  Overview of Applications

  Overview of Applications  

14

Fluids handled

Cal

io-T

her

m S

NC

/NC

V

Cal

io-T

her

m N

C

Cal

io-T

her

m S

Cal

io S

Cal

io

Cal

io Z

Etal

ine

L

Etal

ine

DL

Etal

ine

Etal

ine

Z

Etal

ine-

R

ILN

ILN

C

Meg

alin

e

Etan

orm

Etan

orm

-R

Etab

loc

Etac

hro

m B

Etac

hro

m L

Etan

orm

V

Meg

ano

rm

Meg

ablo

c

Waste water with faeces

Dri

nkin

g w

ater

cir

cula

tors

, fix

ed s

peed

Dri

nkin

g w

ater

cir

cula

tors

, var

iabl

e sp

eed

Circ

ulat

ors,

var

iabl

e sp

eed

In-li

ne p

umps

Stan

dard

ised

/ cl

ose-

coup

led

pum

ps

Waste water without faecesAggressive liquids

Inorganic liquidsActivated sludge

Brackish waterService water

DistillateSlurries

Explosive liquidsDigested sludge

Solids (ore, sand, gravel, ash)Flammable liquids

River, lake and groundwaterLiquefied gas

Food and beverage productionGas-containing liquids

Gas turbine fuelsFiltered water

Geothermal waterHarmful liquids

Toxic liquidsHigh-temperature hot water

Heating waterHighly aggressive liquids

Industrial service waterCondensate

Corrosive liquidsValuable liquids

FuelsCoolants

Cooling lubricantCooling water

Volatile liquidsFire-fighting water

SolventsSeawater

OilsOrganic liquids

Pharmaceutical fluidsPolymerising liquids

Rainwater / stormwaterCleaning agents

Raw sludgeLubricants

Grey waterSwimming pool water

BrineFeed water

Dipping paintsDrinking water

Thermal oilHot water

Wash water

  Overview of Applications

  Overview of Applications  

15

Fluids handled

HPK

-L

HPH

HPK

Etan

orm

SY

T /

RSY

Etab

loc

SYT

Etal

ine

SYT

Meg

aCPK

CPK

N

Mag

no

chem

Mag

no

chem

685

Mag

no

chem

-Blo

c

Etas

eco

/ E

tase

co-I

Etas

eco

RV

P

RPH

RPH

-LF

RPH

b /

RPH

d

RPH

-V

CTN

CH

TR

CH

TRa

CIN

CP

/ C

INC

N

INV

CP

Esti

gia

RW

CP

/ R

WC

N

WK

TR

Hya

-Rai

n /

Hya

-Rai

n N

Hya

-Rai

n E

co

Waste water with faeces

Hot

wat

er p

umps

Hot

wat

er /

ther

mal

oil

pum

ps

Stan

dard

ised

che

mic

al p

umps

Seal

-less

pum

ps

Proc

ess

pum

ps

Rain

wat

er h

arve

stin

g sy

stem

s

Waste water without faecesAggressive liquids

Inorganic liquidsActivated sludge

Brackish waterService water

DistillateSlurries

Explosive liquidsDigested sludge

Solids (ore, sand, gravel, ash)Flammable liquids

River, lake and groundwaterLiquefied gas

Food and beverage productionGas-containing liquids

Gas turbine fuelsFiltered water

Geothermal waterHarmful liquids

Toxic liquidsHigh-temperature hot water

Heating waterHighly aggressive liquids

Industrial service waterCondensate

Corrosive liquidsValuable liquids

FuelsCoolants

Cooling lubricantCooling water

Volatile liquidsFire-fighting water

SolventsSeawater

OilsOrganic liquids

Pharmaceutical fluidsPolymerising liquids

Rainwater / stormwaterCleaning agents

Raw sludgeLubricants

Grey waterSwimming pool water

BrineFeed water

Dipping paintsDrinking water

Thermal oilHot water

Wash water

  Overview of Applications

  Overview of Applications  

16

Fluids handled

Emp

ori

a C

P

Emp

ori

a M

B

Emp

ori

a PD

Mu

lti E

co

Mu

lti E

co-P

ro

Mu

lti E

co-T

op

Ixo

N

Ixo

Pro

Filt

ra N

KSB

Del

ta C

om

pac

t M

VP

KSB

Del

ta E

co M

VP/

SVP

KSB

Del

ta P

rim

o K

/VP/

SVP

KSB

Del

ta S

olo

MV

P/SV

P

Hya

-So

lo D

Hya

-So

lo D

SV

Hya

-So

lo D

FL

Hya

-Du

o D

FL

Hya

-So

lo D

FL

Co

mp

act

Hya

-Du

o D

FL

Co

mp

act

Hya

mat

K

Hya

mat

V

Hya

mat

SV

P

Hya

mat

SV

P EC

O

Surp

ress

chro

m S

IC.2

Surp

ress

chro

m S

IC.2

V

Surp

ress

chro

m S

IC.2

SV

P

Surp

ress

Feu

SFE

Waste water with faeces

Dom

esti

c w

ater

sup

ply

syst

ems

wit

h au

tom

atic

con

trol

uni

t / S

wim

min

g po

ol p

umps

Pres

sure

boo

ster

sys

tem

s

Waste water without faecesAggressive liquids

Inorganic liquidsActivated sludge

Brackish waterService water

DistillateSlurries

Explosive liquidsDigested sludge

Solids (ore, sand, gravel, ash)Flammable liquids

River, lake and groundwaterLiquefied gas

Food and beverage productionGas-containing liquids

Gas turbine fuelsFiltered water

Geothermal waterHarmful liquids

Toxic liquidsHigh-temperature hot water

Heating waterHighly aggressive liquids

Industrial service waterCondensate

Corrosive liquidsValuable liquids

FuelsCoolants

Cooling lubricantCooling water

Volatile liquidsFire-fighting water

SolventsSeawater

OilsOrganic liquids

Pharmaceutical fluidsPolymerising liquids

Rainwater / stormwaterCleaning agents

Raw sludgeLubricants

Grey waterSwimming pool water

BrineFeed water

Dipping paintsDrinking water

Thermal oilHot water

Wash water

  Overview of Applications

  Overview of Applications  

17

Fluids handled

Am

a-D

rain

er N

Am

a-D

rain

er 4

.. /

5..

Am

a-D

rain

er 8

0, 1

00

Am

a-Po

rter

F /

S

Ro

tex

MK

/ M

KY

Am

acle

an

Am

aDS3

Am

a-D

rain

er-B

ox

Min

i

Am

a-D

rain

er-B

ox

Evam

atic

-Bo

x N

min

i-C

om

pac

ta

Co

mp

acta

CK

 800

Pu

mp

Sta

tio

n

CK

 100

0 Pu

mp

Sta

tio

n

Am

a-Po

rter

CK

Pu

mp

Sta

tio

n

SRP

SRL

SRS

Am

arex

N

Am

arex

KR

T

Waste water with faeces

Dra

inag

e pu

mps

 / w

aste

wat

er p

umps

Lift

ing

unit

s / p

acka

ge p

ump

stat

ions

Subm

ersi

ble

mot

or p

umps

Waste water without faecesAggressive liquids

Inorganic liquidsActivated sludge

Brackish waterService water

DistillateSlurries

Explosive liquidsDigested sludge

Solids (ore, sand, gravel, ash)Flammable liquids

River, lake and groundwaterLiquefied gas

Food and beverage productionGas-containing liquids

Gas turbine fuelsFiltered water

Geothermal waterHarmful liquids

Toxic liquidsHigh-temperature hot water

Heating waterHighly aggressive liquids

Industrial service waterCondensate

Corrosive liquidsValuable liquids

FuelsCoolants

Cooling lubricantCooling water

Volatile liquidsFire-fighting water

SolventsSeawater

OilsOrganic liquids

Pharmaceutical fluidsPolymerising liquids

Rainwater / stormwaterCleaning agents

Raw sludgeLubricants

Grey waterSwimming pool water

BrineFeed water

Dipping paintsDrinking water

Thermal oilHot water

Wash water

  Overview of Applications

  Overview of Applications  

18

Fluids handled

Am

acan

K

Am

acan

P

Am

acan

S

Am

amix

Am

apro

p

Am

ajet

Am

alin

e

Sew

atec

Sew

atec

SPN

Sew

ablo

c

KW

P

KW

P-B

loc

WB

C

LSA

-S

LCC

-M

LCC

-R

TBC

LCV

FGD

MH

D

LHD

MD

X

ZW HV

F

Etap

rim

e L

Etap

rim

e B

EZ B

/L

AU

AU

Mo

no

blo

c

Waste water with faeces

Subm

ersi

ble

pum

ps in

dis

char

ge t

ubes

Mix

ers 

/ agi

tato

rs /

tank

cle

anin

g un

its

Pum

ps f

or s

olid

s-la

den

flui

ds

Slur

ry p

umps

Self

-pri

min

g pu

mps

Waste water without faecesAggressive liquids

Inorganic liquidsActivated sludge

Brackish waterService water

DistillateSlurries

Explosive liquidsDigested sludge

Solids (ore, sand, gravel, ash)Flammable liquids

River, lake and groundwaterLiquefied gas

Food and beverage productionGas-containing liquids

Gas turbine fuelsFiltered water

Geothermal waterHarmful liquids

Toxic liquidsHigh-temperature hot water

Heating waterHighly aggressive liquids

Industrial service waterCondensate

Corrosive liquidsValuable liquids

FuelsCoolants

Cooling lubricantCooling water

Volatile liquidsFire-fighting water

SolventsSeawater

OilsOrganic liquids

Pharmaceutical fluidsPolymerising liquids

Rainwater / stormwaterCleaning agents

Raw sludgeLubricants

Grey waterSwimming pool water

BrineFeed water

Dipping paintsDrinking water

Thermal oilHot water

Wash water

  Overview of Applications

  Overview of Applications  

19

Fluids handled

UPA

chro

m 1

00 C

C

UPA

chro

m 1

00 C

N

UPA

150

C

UPA

200

, 200

B, 2

50C

UPA

300

, 350

UPA

-Z /

UPA

-R

B P

um

p

Co

meo

Mo

vite

c H

(S)I

Mo

vite

c

Mo

vite

c V

CI

Mu

ltit

ec

Om

ega

RD

LO

RD

LP

Vit

ach

rom

Vit

acas

t /

Vit

acas

t B

loc

Vit

apri

me

Vit

asta

ge

Vit

alo

be

CH

TA /

CH

TC /

CH

TD

HG

B /

HG

C /

HG

D

HG

I

HG

M

YN

K

LUV

/ L

UV

A

WK

TB

Waste water with faeces

Subm

ersi

ble

bore

hole

pum

ps

Ver

tica

l tur

bine

pum

ps

Hig

h-pr

essu

re p

umps

Axi

ally

spl

it p

umps

Hyg

ieni

c pu

mps

for

the

foo

d, b

ever

age

and

phar

mac

euti

cal i

ndus

trie

s

Pum

ps f

or p

ower

sta

tion

con

vent

iona

l isl

ands

Waste water without faecesAggressive liquids

Inorganic liquidsActivated sludge

Brackish waterService water

DistillateSlurries

Explosive liquidsDigested sludge

Solids (ore, sand, gravel, ash)Flammable liquids

River, lake and groundwaterLiquefied gas

Food and beverage productionGas-containing liquids

Gas turbine fuelsFiltered water

Geothermal waterHarmful liquids

Toxic liquidsHigh-temperature hot water

Heating waterHighly aggressive liquids

Industrial service waterCondensate

Corrosive liquidsValuable liquids

FuelsCoolants

Cooling lubricantCooling water

Volatile liquidsFire-fighting water

SolventsSeawater

OilsOrganic liquids

Pharmaceutical fluidsPolymerising liquids

Rainwater / stormwaterCleaning agents

Raw sludgeLubricants

Grey waterSwimming pool water

BrineFeed water

Dipping paintsDrinking water

Thermal oilHot water

Wash water

  Overview of Applications

  Overview of Applications  

20

Fluids handled

SEZ

/ SE

ZT /

PH

Z /

PNZ

SNW

/ P

NW

Bev

ero

n

SPY

RER

RSR

RU

V

PSR

RH

D

LUV

Nu

clea

r

RH

M

RV

M

RH

R

RV

R

RPH

-RO

HG

M-R

O

Mu

ltit

ec-R

O

RC

/ R

CV

EDS

DU

/ E

U

KSB

Su

Prem

E

KSB

UM

A-S

Pum

pD

rive

2/P

um

pD

rive

2 E

co

Pum

pD

rive

R

Pum

pM

eter

KSB

Gu

ard

Waste water with faeces

Pum

ps f

or p

ower

sta

tion

con

vent

iona

l isl

ands

Pum

ps f

or n

ucle

ar p

ower

sta

tion

s

Pum

ps f

or d

esal

inat

ion

by r

ever

se o

smos

is

Posi

tive

dis

plac

emen

t pu

mps

Fire

-fig

htin

g sy

stem

s

Dri

ves

Var

iabl

e sp

eed

syst

ems

Mon

itor

ing

and

diag

nosi

s

Waste water without faecesAggressive liquids

Inorganic liquidsActivated sludge

Brackish waterService water

DistillateSlurries

Explosive liquidsDigested sludge

Solids (ore, sand, gravel, ash)Flammable liquids

River, lake and groundwaterLiquefied gas

Food and beverage productionGas-containing liquids

Gas turbine fuelsFiltered water

Geothermal waterHarmful liquids

Toxic liquidsHigh-temperature hot water

Heating waterHighly aggressive liquids

Industrial service waterCondensate

Corrosive liquidsValuable liquids

FuelsCoolants

Cooling lubricantCooling water

Volatile liquidsFire-fighting water

SolventsSeawater

OilsOrganic liquids

Pharmaceutical fluidsPolymerising liquids

Rainwater / stormwaterCleaning agents

Raw sludgeLubricants

Grey waterSwimming pool water

BrineFeed water

Dipping paintsDrinking water

Thermal oilHot water

Wash water

  Overview of Applications

  Overview of Applications  

21

Applications

Cal

io-T

her

m S

NC

/NC

V

Cal

io-T

her

m N

C

Cal

io-T

her

m S

Cal

io S

Cal

io

Cal

io Z

Etal

ine

L

Etal

ine

DL

Etal

ine

Etal

ine

Z

Etal

ine-

R

ILN

ILN

C

Meg

alin

e

Etan

orm

Etan

orm

-R

Etab

loc

Etac

hro

m B

Etac

hro

m L

Etan

orm

V

Meg

ano

rm

Meg

ablo

c

Aquaculture

Dri

nkin

g w

ater

cir

cula

tors

, fix

ed s

peed

Dri

nkin

g w

ater

cir

cula

tors

, var

iabl

e sp

eed

Circ

ulat

ors,

var

iabl

e sp

eed

In-li

ne p

umps

Stan

dard

ised

/ cl

ose-

coup

led

pum

ps

Spray irrigationMining

IrrigationChemical industry

Dock facilitiesDrainage

Pressure boostingSludge thickening

DisposalDewatering

Descaling unitsDistrict heatingSolids transport

Fire-fighting systemsGeothermal energy applications

Drawdown of groundwater levelsMaintaining groundwater levels

Domestic water supplyFlood control / coast protection

HomogenisationIndustrial recirculation systems

Nuclear power stationsBoiler feed applications

Boiler recirculationWaste water treatment plants

Air-conditioning systemsCondensate transport

Cooling circuitsPaint shops

Food and beverage industrySeawater desalination / reverse osmosis

MixingOffshore platforms

Paper and pulp industryPetrochemical industry

Pharmaceutical industryPipelines and tank farms

RefineriesFlue gas desulphurisation

Rainwater harvestingCleaning of stormwater tanks / storage sewers

RecirculationDredging

ShipbuildingSludge disposal

Sludge processingSnow-making systems

Heavy oil and coal upgradingSwimming pools

Solar thermal energy systemsFountains

Keeping in suspensionThermal oil circulation

Draining of pits, shafts, etc.Process engineering

Heat recovery systemsHot-water heating systems

Washing plantsWater treatmentWater extraction

Water supplySugar industry

  Overview of Applications

  Overview of Applications  

22

Applications

HPK

-L

HPH

HPK

Etan

orm

SY

T /

RSY

Etab

loc

SYT

Etal

ine

SYT

Meg

aCPK

CPK

N

Mag

no

chem

Mag

no

chem

685

Mag

no

chem

-Blo

c

Etas

eco

/ E

tase

co-I

Etas

eco

RV

P

RPH

RPH

-LF

RPH

b /

RPH

d

RPH

-V

CTN

CH

TR

CH

TRa

CIN

CP

/ C

INC

N

INV

CP

Esti

gia

RW

CP

/ R

WC

N

WK

TR

Hya

-Rai

n /

Hya

-Rai

n N

Hya

-Rai

n E

co

Aquaculture

Hot

wat

er p

umps

Hot

wat

er /

ther

mal

oil

pum

ps

Stan

dard

ised

che

mic

al p

umps

Seal

-less

pum

ps

Proc

ess

pum

ps

Rain

wat

er h

arve

stin

g sy

stem

s

Spray irrigationMining

IrrigationChemical industry

Dock facilitiesDrainage

Pressure boostingSludge thickening

DisposalDewatering

Descaling unitsDistrict heatingSolids transport

Fire-fighting systemsGeothermal energy applications

Drawdown of groundwater levelsMaintaining groundwater levels

Domestic water supplyFlood control / coast protection (stormwater)

HomogenisationIndustrial recirculation systems

Nuclear power stationsBoiler feed applications

Boiler recirculationWaste water treatment plants

Air-conditioning systemsCondensate transport

Cooling circuitsPaint shops

Food and beverage industrySeawater desalination / reverse osmosis

MixingOffshore platforms

Paper and pulp industryPetrochemical industry

Pharmaceutical industryPipelines and tank farms

RefineriesFlue gas desulphurisation

Rainwater harvestingCleaning of stormwater tanks / storage sewers

RecirculationDredging

ShipbuildingSludge disposal

Sludge processingSnow-making systems

Heavy oil and coal upgradingSwimming pools

Solar thermal energy systemsFountains

Keeping in suspensionThermal oil circulation

Draining of pits, shafts, etc.Process engineering

Heat recovery systemsHot-water heating systems

Washing plantsWater treatmentWater extraction

Water supplySugar industry

  Overview of Applications

  Overview of Applications  

23

Applications

Emp

ori

a C

P

Emp

ori

a M

B

Emp

ori

a PD

Mu

lti E

co

Mu

lti E

co-P

ro

Mu

lti E

co-T

op

Ixo

N

Ixo

-Pro

Filt

ra N

KSB

Del

ta C

om

pac

t M

VP

KSB

Del

ta E

co M

VP/

SVP

KSB

Del

ta P

rim

o K

/VP/

SVP

KSB

Del

ta S

olo

MV

P/SV

P

Hya

-So

lo D

Hya

-So

lo D

SV

Hya

-So

lo D

FL

Hya

-Du

o D

FL

Hya

-So

lo D

FL

Co

mp

act

Hya

-Du

o D

FL

Co

mp

act

Hya

mat

K

Hya

mat

V

Hya

mat

SV

P

Hya

mat

SV

P EC

O

Surp

ress

chro

m S

IC.2

Surp

ress

chro

m S

IC.2

V

Surp

ress

chro

m S

IC.2

SV

P

Surp

ress

Feu

SFE

Aquaculture

Dom

esti

c w

ater

sup

ply

syst

ems

wit

h au

tom

atic

con

trol

uni

t / S

wim

min

g po

ol p

umps

Pres

sure

boo

ster

sys

tem

s

Spray irrigationMining

IrrigationChemical industry

Dock facilitiesDrainage

Pressure boostingSludge thickening

DisposalDewatering

Descaling unitsDistrict heatingSolids transport

Fire-fighting systemsGeothermal energy applications

Drawdown of groundwater levelsMaintaining groundwater levels

Domestic water supplyFlood control / coast protection (stormwater)

HomogenisationIndustrial recirculation systems

Nuclear power stationsBoiler feed applications

Boiler recirculationWaste water treatment plants

Air-conditioning systemsCondensate transport

Cooling circuitsPaint shops

Food and beverage industrySeawater desalination / reverse osmosis

MixingOffshore platforms

Paper and pulp industryPetrochemical industry

Pharmaceutical industryPipelines and tank farms

RefineriesFlue gas desulphurisation

Rainwater harvestingCleaning of stormwater tanks / storage sewers

RecirculationDredging

ShipbuildingSludge disposal

Sludge processingSnow-making systems

Heavy oil and coal upgradingSwimming pools

Solar thermal energy systemsFountains

Keeping in suspensionThermal oil circulation

Draining of pits, shafts, etc.Process engineering

Heat recovery systemsHot-water heating systems

Washing plantsWater treatmentWater extraction

Water supplySugar industry

  Overview of Applications

  Overview of Applications  

24

Applications

Am

a-D

rain

er N

Am

a-D

rain

er 4

.. /

5..

Am

a-D

rain

er 8

0, 1

00

Am

a-Po

rter

F /

S

Ro

tex

MK

/ M

KY

Am

acle

an

Am

aDS3

Am

a-D

rain

er-B

ox

Min

i

Am

a-D

rain

er-B

ox

Evam

atic

-Bo

x N

min

i-C

om

pac

ta

Co

mp

acta

CK

 800

Pu

mp

Sta

tio

n

CK

 100

0 Pu

mp

Sta

tio

n

Am

a-Po

rter

CK

Pu

mp

Sta

tio

n

SRP

SRL

SRS

Am

arex

N

Am

arex

KR

T

Aquaculture

Dra

inag

e pu

mps

 / w

aste

wat

er p

umps

Lift

ing

unit

s / p

acka

ge p

ump

stat

ions

Subm

ersi

ble

mot

or p

umps

Spray irrigation

Mining

Irrigation

Chemical industry

Dock facilities

Drainage

Pressure boosting

Sludge thickening

Disposal

Dewatering

Descaling units

District heating

Solids transport

Fire-fighting systems

Geothermal energy applications

Drawdown of groundwater levels

Maintaining groundwater levels

Domestic water supply

Flood control / coast protection (stormwater)

Homogenisation

Industrial recirculation systems

Nuclear power stations

Boiler feed applications

Boiler recirculation

Waste water treatment plants

Air-conditioning systems

Condensate transport

Cooling circuits

Paint shops

Food and beverage industry

Seawater desalination / reverse osmosis

Mixing

Offshore platforms

Paper and pulp industry

Petrochemical industry

Pharmaceutical industry

Pipelines and tank farms

Refineries

Flue gas desulphurisation

Rainwater harvesting

Cleaning of stormwater tanks / storage sewers

Recirculation

Dredging

Shipbuilding

Sludge disposal

Sludge processing

Snow-making systems

Heavy oil and coal upgrading

Swimming pools

Solar thermal energy systems

Fountains

Keeping in suspension

Thermal oil circulation

Draining of pits, shafts, etc.

Process engineering

Heat recovery systems

Hot-water heating systems

Washing plants

Water treatment

Water extraction

Water supply

Sugar industry

  Overview of Applications

  Overview of Applications  

25

Applications

Am

acan

K

Am

acan

P

Am

acan

S

Am

amix

Am

apro

p

Am

ajet

Am

alin

e

Sew

atec

Sew

atec

SPN

Sew

ablo

c

KW

P

KW

P-B

loc

WB

C

LSA

-S

LCC

-M

LCC

-R

TBC

LCV

FGD

MH

D

LHD

MD

X

ZW HV

F

Etap

rim

e L

Etap

rim

e B

EZ B

/L

AU

AU

Mo

no

blo

c

Aquaculture

Subm

ersi

ble

pum

ps in

dis

char

ge t

ubes

Mix

ers 

/ agi

tato

rs /

tank

cle

anin

g un

its

Pum

ps f

or s

olid

s-la

den

flui

ds

Slur

ry p

umps

Self

-pri

min

g pu

mps

Spray irrigationMining

IrrigationChemical industry

Dock facilitiesDrainage

Pressure boostingSludge thickening

DisposalDewatering

Descaling unitsDistrict heatingSolids transport

Geothermal energy applicationsFire-fighting systems

Drawdown of groundwater levelsMaintaining groundwater levels

Domestic water supplyFlood control / coast protection (stormwater)

HomogenisationIndustrial recirculation systems

Nuclear power stationsBoiler feed applications

Boiler recirculationWaste water treatment plants

Air-conditioning systemsCondensate transport

Cooling circuitsPaint shops

Food and beverage industrySeawater desalination / reverse osmosis

MixingOffshore platforms

Paper and pulp industryPetrochemical industry

Pharmaceutical industryPipelines and tank farms

RefineriesFlue gas desulphurisation

Rainwater harvestingCleaning of stormwater tanks / storage sewers

RecirculationDredging

ShipbuildingSludge disposal

Sludge processingSnow-making systems

Heavy oil and coal upgradingSwimming pools

Solar thermal energy systemsFountains

Keeping in suspensionThermal oil circulation

Draining of pits, shafts, etc.Process engineering

Heat recovery systemsHot-water heating systems

Washing plantsWater treatmentWater extraction

Water supplySugar industry

  Overview of Applications

  Overview of Applications  

26

Applications

UPA

chro

m 1

00 C

C

UPA

chro

m 1

00 C

N

UPA

150

C

UPA

200

, 200

B, 2

50C

UPA

300

, 350

UPA

-Z /

UPA

-R

B P

um

p

Co

meo

Mo

vite

c H

(S)I

Mo

vite

c

Mo

vite

c V

CI

Mu

ltit

ec

Om

ega

RD

LO

RD

LP

Vit

ach

rom

Vit

acas

t /

Vit

acas

t B

loc

Vit

apri

me

Vit

asta

ge

Vit

alo

be

CH

TA /

CH

TC /

CH

TD

HG

B /

HG

C /

HG

D

HG

I

HG

M

YN

K

LUV

/ L

UV

A

WK

TB

Aquaculture

Subm

ersi

ble

bore

hole

pum

ps

Ver

tica

l tur

bine

pum

ps

Hig

h-pr

essu

re p

umps

Axi

ally

spl

it p

umps

Hyg

ieni

c pu

mps

for

the

foo

d, b

ever

age

and

phar

mac

euti

cal i

ndus

trie

s

Pum

ps f

or p

ower

sta

tion

con

vent

iona

l isl

ands

Spray irrigationMining

IrrigationChemical industry

Dock facilitiesDrainage

Pressure boostingSludge thickening

DisposalDewatering

Descaling unitsDistrict heatingSolids transport

Fire-fighting systemsGeothermal energy applications

Drawdown of groundwater levelsMaintaining groundwater levels

Domestic water supplyFlood control / coast protection (stormwater)

HomogenisationIndustrial recirculation systems

Nuclear power stationsBoiler feed applications

Boiler recirculationWaste water treatment plants

Air-conditioning systemsCondensate transport

Cooling circuitsPaint shops

Food and beverage industrySeawater desalination / reverse osmosis

MixingOffshore platforms

Paper and pulp industryPetrochemical industry

Pharmaceutical industryPipelines and tank farms

RefineriesFlue gas desulphurisation

Rainwater harvestingCleaning of stormwater tanks / storage sewers

RecirculationDredging

ShipbuildingSludge disposal

Sludge processingSnow-making systems

Heavy oil and coal upgradingSwimming pools

Solar thermal energy systemsFountains

Keeping in suspensionThermal oil circulation

Draining of pits, shafts, etc.Process engineering

Heat recovery systemsHot-water heating systems

Washing plantsWater treatmentWater extraction

Water supplySugar industry

  Overview of Applications

  Overview of Applications  

27

Applications

SEZ

/ SE

ZT /

PH

Z /

PNZ

SNW

/ P

NW

Bev

ero

n

SPY

RER

RSR

RU

V

PSR

RH

D

LUV

Nu

clea

r

RH

M

RV

M

RH

R

RV

R

RPH

-RO

HG

M-R

O

Mu

ltit

ec-R

O

RC

/ R

CV

EDS

DU

/ E

U

KSB

Su

Prem

E

KSB

UM

A-S

Pum

pD

rive

2/P

um

pD

rive

2 E

co

Pum

pD

rive

R

Pum

pM

eter

KSB

Gu

ard

Aquaculture

Pum

ps f

or p

ower

sta

tion

con

vent

iona

l isl

ands

Pum

ps f

or n

ucle

ar p

ower

sta

tion

s

Pum

ps f

or d

esal

inat

ion

by r

ever

se o

smos

is

Posi

tive

dis

plac

emen

t pu

mps

Fire

-fig

htin

g sy

stem

s

Dri

ves

Var

iabl

e sp

eed

syst

ems

Mon

itor

ing

and

diag

nosi

s

Spray irrigationMining

IrrigationChemical industry

Dock facilitiesDrainage

Pressure boostingSludge thickening

DisposalDewatering

Descaling unitsDistrict heatingSolids transport

Fire-fighting systemsGeothermal energy applications

Drawdown of groundwater levelsMaintaining groundwater levels

Domestic water supplyFlood control / coast protection (stormwater)

HomogenisationIndustrial recirculation systems

Nuclear power stationsBoiler feed applications

Boiler recirculationWaste water treatment plants

Air-conditioning systemsCondensate transport

Cooling circuitsPaint shops

Food and beverage industrySeawater desalination / reverse osmosis

MixingOffshore platforms

Paper and pulp industryPetrochemical industry

Pharmaceutical industryPipelines and tank farms

RefineriesFlue gas desulphurisation

Rainwater harvestingCleaning of stormwater tanks / storage sewers

RecirculationDredging

ShipbuildingSludge disposal

Sludge processingSnow-making systems

Heavy oil and coal upgradingSwimming pools

Solar thermal energy systemsFountains

Keeping in suspensionThermal oil circulation

Draining of pits, shafts, etc.Process engineering

Heat recovery systemsHot-water heating systems

Washing plantsWater treatmentWater extraction

Water supplySugar industry

  Automation

  Automation  

28

Drive, variable speed system and monitoring

KSB SuPremENo. of pumpsU [V]

≤ 1Power supply via

PumpDrive /PumpDrive R only

Description:IEC-compatible, sensorless, magnetless synchronous reluctance motor ofefficiency class IE4/IE5 (super/ultra premium efficiency) toIEC TS 60034-30-2:2016 for operation on a KSB PumpDrive 2, PumpDrive 2 Ecoor PumpDrive R variable speed system. Suitable for connection to three-phase380-480 V mains (via PumpDrive). The motor mounting points comply withEN 50347 specifications to ensure compatibility with standardised IEC framemotor applications and full interchangeability with IE2 or IE3 standardisedasynchronous motors. Envelope dimensions lie within the limits for IE2 / IE3motors as recommended in DIN V 42673 (07-2011). The motor is controlledwithout rotor position sensors. The efficiency of the motor also exceeds95 percent of nominal efficiency when the motor runs at 25 percent of itsnominal power on a quadratic torque-speed curve. The motor is magnetlesswhich means that, in particular, so-called rare earths are not used inproduction. Drive production is thus sustainable and environmentally friendly.Applications:For use with dry-installed variable speed pumps which can be driven bystandardised foot-mounted and/or flange-mounted motors.

http://shop.ksb.com/catalog/k0/en/product/ES000866

KSB UMA-SNo. of pumpsU [V]

≤ 1Power supply via

PumpDrive R

Description:Permanent-magnet submersible synchronous motor, for operation on a KSBPumpDrive R variable speed system. Suitable for a three-phase 380 - 400 Vmains. NEMA connections and identical outside diameters ensure fullinterchangeability with comparable 6" or 8" asynchronous motors. The motoris controlled without rotor position sensors. The motor efficiency is 5 - 12 %above that of asynchronous motors. Given the design and functionality theuse of permanent magnets is essential.Applications:Exclusively for submersible borehole pumps in the range of 4 - 150 kW.

http://shop.ksb.com/catalog/k0/en/product/ES000003

PumpDrive 2 / PumpDrive 2 EcoNo. of pumpsP [kW]U [V]Frequency inverter

≤ 655

3~380 - 4801 per motor

Description:Self-cooling variable speed system which allows the motor speed to be variedcontinuously by means of standard signals and a field bus. As PumpDrive isself-cooling, it can be mounted on the motor, on the wall or in a controlcabinet. From two to six pumps can be controlled without needing anadditional controller.Applications:Air-conditioning systems, heat generation, heat distribution, water supplysystems, water extraction, water treatment, water distribution, watertransport, refrigeration, cooling distribution, heat generation, heatdistribution, fluid transport, cooling lubricant distribution, industrial watersupply, tank drainage, waste water transport

http://shop.ksb.com/catalog/k0/en/product/ES000911

PumpDrive RNo. of pumpsP [kW]U [V]Frequency inverter

≤ 655

3~380 - 4801 per motor

Description:PumpDrive R is a frequency inverter for wall or cabinet mounting designedfor variable speed control and other control functions for asynchronousmotors, synchronous reluctance motors like KSB SuPremE, or permanentmagnet synchronous motors. PumpDrive R extends the power range of KSBPumpDrive up to a rated power of 110 kW as standard or up to 1.4 MW (onrequest).Applications:Air-conditioning systems, heat generation, heat distribution, water supplysystems, water extraction, water treatment, water distribution, watertransport, refrigeration, cooling distribution, heat generation, heatdistribution, fluid transport, cooling lubricant distribution, industrial watersupply, tank drainage, waste water transport

http://shop.ksb.com/catalog/k0/en/product/ES000898

Not available for worldwide sale

  Automation

  Automation  

29

PumpMeterNo. of pumpsU [V DC]

≤ 124

Description:The PumpMeter device is designed for monitoring pump operation. It is anintelligent pressure transmitter for pumps, with on-site display of measuredvalues and operating data. It records the load profile of the pump in order toindicate any potential for optimising energy efficiency and availability. Thedevice comprises two pressure sensors and a display unit. PumpMeter issupplied completely assembled and parameterised for the pump it is usedwith. It is ready for operation as soon as the M12 plug connector is pluggedin.Applications:Air-conditioning systems, cooling circuits, cooling lubricant distribution,heating systems, water treatment plants, water supply systems, waterdistribution systems, water transport systems, water extraction systems

http://shop.ksb.com/catalog/k0/en/product/ES000807

KSB GuardNumber of pumpsU [V AC]

U [V DC]

≤ 20 (per gateway)110 - 240

(gateway)2 x 1,5 (sensor)

Description:System for monitoring pump condition: Sensors on the pump record vibrationand temperature data, which is processed in the KSB Cloud. Information onthe pump's condition can then be accessed using the KSB Guard App orthrough the web portal. Easy to retrofit on pumps during operation.Applications:For monitoring dry-installed pumps, optimising maintenance and improvingsystem availability

http://shop.ksb.com/catalog/k0/en/product/ES000938

  Pumps

  Pumps  

30

Drinking water circulators, fixed speed

Calio-Therm S NC/NCVRpQ [m3/h]H [m]p [bar]T [°C]

1/2 - 3/4≤ 0,7

≤ 1≤ 10

≥ +5 - ≤ +65

Description:Maintenance-free, high-efficiency glandless drinking water circulator pump,screw-ended, electric motor with multiple fixed speed levels, for use indrinking water supply systems.Applications:Drinking water circulation systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000918

Calio-Therm NCRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

3/4 - 1≤ 9≤ 7

≤ 10≥ +2 - ≤ +65

≤ 2800

Description:Maintenance-free, fixed speed glandless drinking water circulator pump,screw-ended, electric motor with multiple fixed speed levels, for use indrinking water supply systems and hot water supply systems.Applications:Drinking water supply systems, hot water supply systems and similar systemsin industry and building services (e.g. cooling water recirculation)

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000928

Drinking water circulators, variable speed

Calio-Therm SRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1≤ 3,5

≤ 6≤ 10

≥ +2 - ≤ +65≤ 3000

Description:Maintenance-free, high-efficiency variable speed glandless drinking watercirculator pump, screw-ended, electric motor and continuously variabledifferential pressure control for use in drinking water supply systems and hotwater supply systems.Applications:Hot water supply, drinking water circulation systems and similar systems inindustry and building services (e.g. cooling water recirculation).Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000882

Circulators, variable speed

Calio SRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1/2 - 1 1/4≤ 3,5

≤ 6≤ 10

≥ +2 - ≤ +95≤ 3000

Description:Maintenance-free high-efficiency screw-ended glandless pump with high-efficiency electric motor and continuously variable differential pressurecontrol.Applications:Heating, ventilation, air-conditioning and heat recovery systems, coolingsystems, industrial recirculation systems.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000910

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

31

CalioRpDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 1/2 - 232 - 100

≤ 51≤ 18≤ 16

≥ -10 - ≤ +110≤ 4500

Description:Maintenance-free high-efficiency flanged or screw-ended glandless pumpwith high-efficiency electric motor and continuously variable differentialpressure control.Applications:Heating, ventilation, air-conditioning and heat recovery systems, coolingsystems, industrial recirculation systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000881

Calio ZRpDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 1/432 - 65

≤ 70≤ 18≤ 16

≥ -10 - ≤ +110≤ 4500

Description:Maintenance-free high-efficiency flanged or screw-ended glandless pump intwin pump design with high-efficiency electric motor and continuouslyvariable differential pressure control.Applications:Heating, ventilation, air-conditioning and heat recovery systems, coolingsystems, industrial recirculation systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000913

In-line pumps

Etaline LRpDNQ [m3/h]H [m]p [bar]T [°C]

1 - 1 1/432 - 80

≤ 95≤ 21≤ 10

≥ -15 - ≤ +120

Description:Single-stage close-coupled in-line volute casing pump, with PumpDrivevariable speed system and common motor/pump shaftApplications:Heating systems, air-conditioning systems, cooling circuits, water supplysystems (not approved for drinking water according to the GermanEnvironment Agency), service water supply systems, industrial recirculationsystems, swimming poolsData for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000925

Etaline DLRpDNQ [m3/h]H [m]p [bar]T [°C]

1 1/432 - 80

≤ 150≤ 21≤ 10

≥ -15 - ≤ +120

Description:Single-stage close-coupled in-line volute casing pump as twin pump, withPumpDrive variable speed system and common motor/pump shaftApplications:Heating systems, air-conditioning systems, cooling circuits, water supplysystems (not approved for drinking water according to the GermanEnvironment Agency), service water supply systems, industrial recirculationsystemsData for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000926

  Pumps

  Pumps  

32

EtalineDNQ [m3/h]H [m]p [bar]T [°C]

32 - 200≤ 700

≤ 96≤ 16

≥ -30 - ≤ +140

Description:Single-stage volute casing pump in in-line design, with magnetlessKSB SuPremE motor of efficiency class IE4/IE5 and PumpDrive variable speedsystem; pump shaft and motor shaft are rigidly connected. With KSB SuPremE,a magnetless synchronous reluctance motor of efficiency class IE4/IE5 toIEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 orKSB PumpDrive 2 Eco variable speed system without rotor position sensors.Motor mounting points in accordance with EN 50347, envelope dimensions inaccordance with DIN V 42673 (07-2011). ATEX-compliant version available.Applications:Hot water heating, cooling circuits, air-conditioning, water supply systems,service water supply systems, industrial recirculation systems

Data for 50 Hz operation

Also available for 60 Hz

PumpMeter, PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000113

Etaline ZDNQ [m3/h]H [m]p [bar]T [°C]

32 - 200≤ 1095≤ 38,5

≤ 16≥ -30 - ≤ +140

Description:Single-stage volute casing pump in in-line design as twin pump, withmagnetless KSB SuPremE motor of efficiency class IE4/IE5 and PumpDrivevariable speed system; pump shaft and motor shaft are rigidly connected. AnM12 module (accessory) enables redundant operation of Etaline Z without theneed for a higher-level controller. With KSB SuPremE, a magnetlesssynchronous reluctance motor of efficiency class IE4/IE5 toIEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 orKSB PumpDrive 2 Eco variable speed system without rotor position sensors.Motor mounting points in accordance with EN 50347, envelope dimensions inaccordance with DIN V 42673 (07-2011). ATEX-compliant version available.Applications:Hot water heating, cooling circuits, air-conditioning, water supply systems,service water supply systems, industrial recirculation systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000114

Etaline-RDNQ [m3/h]H [m]p [bar]T [°C]

150 - 350≤ 1900

≤ 93≤ 25

≥ -30 - ≤ +140

Description:Vertical close-coupled in-line pump with volute casing and magnetlessKSB SuPremE motor of efficiency class IE4/IE5 and PumpDrive variable speedsystem; ATEX-compliant version available.Applications:Hot water heating, cooling circuits, air-conditioning, water supply systems,service water supply systems, industrial recirculation systemsData for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000812

ILNDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

65 - 400≤ 3100

≤ 112≤ 16

≥ -20 - ≤ +70≤ 3000

Description:Vertical in-line centrifugal pump with closed impeller and mechanical seal.ILNS fitted with an auxiliary vacuum pump, ILNE with ejector. The back pull-out design allows the impeller to be dismantled without removing the pipesand the motor. ATEX-compliant version available.Applications:Hot-water heating systems, cooling circuits, air-conditioning systems, marineapplications, water and service water supply systems, cleaning systems andindustrial recirculation systems.

Data for 50 Hz operation

Also available for 60 Hz

Control unit http://shop.ksb.com/catalog/k0/en/product/ES000730

ILNCDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

32 - 125≤ 370≤ 112

≤ 16≥ -20 - ≤ +70

≤ 3000

Description:Vertical close-coupled centrifugal pump in in-line design, with electric motor,closed impeller and mechanical seal. ILNCS fitted with an auxiliary vacuumpump, ILNCE with ejector. Standardised IEC frame motor. ATEX-compliantversion available.Applications:Hot-water heating systems, cooling circuits, air-conditioning systems, marineapplications, water and service water supply systems, cleaning systems andindustrial recirculation systems.

Data for 50 Hz operation

Also available for 60 Hz

Control unit http://shop.ksb.com/catalog/k0/en/product/ES000732

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

33

MegalineDNQ [m3/h]H [m]p [bar]T [°C]

32 - 200≤ 600≤ 135

≤ 16≥ 0 - ≤ +90

Description:Volute casing pump for horizontal or vertical installation, in back pull-outdesign, single-stage, radially split volute casing, replaceable casing wear rings.Volute casing in in-line design with closed radial impeller, with multiplycurved vanes, single mechanical seal to EN 12756.Applications:Heating circuits, water supply systems, air-conditioning systems, waste water,industrial recirculation systems

Data for 60 Hz operation

http://www.ksb.com.br/ksb-br-pt/pesquisa.php?_q=megaline

Standardised / close-coupled pumps

EtanormDNQ [m3/h]H [m]p [bar]T [°C]

25 - 150≤ 640≤ 160

≤ 16≥ -30 - ≤ +140

Description:Horizontal volute casing pump, single-stage, with ratings and maindimensions to EN 733, long-coupled, back pull-out design, with replaceableshaft sleeves / shaft protecting sleeves and casing wear rings, with motor-mounted variable speed system. With KSB SuPremE, a magnetlesssynchronous reluctance motor of efficiency class IE4/IE5 toIEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 orKSB PumpDrive 2 Eco variable speed system without rotor position sensors.Motor mounting points in accordance with EN 50347, envelope dimensions inaccordance with DIN V 42673 (07-2011). ATEX-compliant version available.Applications:Pumping clean or aggressive liquids not chemically or mechanically aggressiveto the pump materials in water supply systems, cooling circuits, swimmingpools, fire-fighting systems, irrigation systems, drainage systems, heatingsystems, air-conditioning systems, spray irrigation systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000062

Etanorm-RDNQ [m3/h]H [m]p [bar]T [°C]

125 - 300≤ 1900

≤ 101≤ 16

≥ -30 - ≤ +140

Description:Horizontal long-coupled, single-stage (two-stage for pump size 125-500)volute casing pump in back pull-out design, with replaceable shaft sleeves /shaft protecting sleeves and casing wear rings, with magnetless KSB SuPremEmotor of efficiency class IE4/IE5 and PumpDrive variable speed system; ATEX-compliant version available.Applications:Water supply systems, spray irrigation systems, drainage systems, air-conditioning systems, fire-fighting systems, general irrigation systems, heatingsystems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000058

EtablocDNQ [m3/h]H [m]p [bar]T [°C]

25 - 150≤ 660≤ 140

≤ 16≥ -30 - ≤ +140

Description:Single-stage close-coupled volute casing pump, with ratings to EN 733, withreplaceable shaft sleeve and casing wear rings, with motor-mounted variablespeed system. With KSB SuPremE, a magnetless synchronous reluctance motorof efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, for operation with theKSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speed system without rotorposition sensors. Motor mounting points in accordance with EN 50347,envelope dimensions in accordance with DIN V 42673 (07-2011). ATEX-compliant version available.Applications:Pumping clean or aggressive liquids not chemically or mechanically aggressiveto the pump materials in water supply systems, cooling water circuits,swimming pools, fire-fighting systems, irrigation systems, drainage systems,heating systems, air-conditioning systems, spray irrigation systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000107

  Pumps

  Pumps  

34

Etachrom BDNQ [m3/h]H [m]p [bar]T [°C]

25 - 80≤ 260≤ 105

≤ 12≥ -30 - ≤ +110

Description:Horizontal single-stage close-coupled annular casing pump, with ratings andmain dimensions to EN 733, with replaceable casing wear rings and motor-mounted variable speed system. With KSB SuPremE, a magnetlesssynchronous reluctance motor of efficiency class IE4/IE5 toIEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 orKSB PumpDrive 2 Eco variable speed system without rotor position sensors.Motor mounting points in accordance with EN 50347, envelope dimensions inaccordance with DIN V 42673 (07-2011). ATEX-compliant version available.Applications:Cleaning systems (bottle rinsing, crate washing, etc.), water treatment plants,water supply systems, fire-fighting systems, spray irrigation systems, irrigationsystems, drainage systems, hot-water heating systems, air-conditioningsystems, industrial washing plants, general industry, disposal of paint sludge,surface treatment

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000066

Etachrom LDNQ [m3/h]H [m]p [bar]T [°C]

25 - 80≤ 260≤ 105

≤ 12≥ -30 - ≤ +110

Description:Horizontal single-stage annular casing pump, with ratings and maindimensions to EN 733, with replaceable casing wear rings and motor-mountedvariable speed system. With KSB SuPremE, a magnetless synchronousreluctance motor of efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, foroperation with the KSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speedsystem without rotor position sensors. Motor mounting points in accordancewith EN 50347, envelope dimensions in accordance with DIN V 42673(07-2011). ATEX-compliant version available.Applications:Cleaning systems (bottle rinsing, crate washing, etc.), water treatment plants,water supply systems, fire-fighting systems, spray irrigation systems, irrigationsystems, drainage systems, hot-water heating systems, air-conditioningsystems, industrial washing plants, general industry, disposal of paint sludge,surface treatment

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000065

Etanorm VDNQ [m3/h]H [m]p [bar]T [°C]

32 - 150≤ 625≤ 100

≤ 16≥ -15 - ≤ +95

Description: Single-stage volute casing pump for vertical installation in closed tanks underatmospheric pressure, with ratings to EN 733. Suitable for immersion depthsof up to 2000 mm.Applications:Phosphating solutions, lubricating oil supply and sealing oil supply forturbines, generators, large compressors, large gear unitsData for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000015

MeganormDNQ [m3/h]H [m]p [bar]T [°C]

25 - 200≤ 1160

≤ 162≤ 16

≥ -30 - ≤ +140

Description:Horizontal, radially split volute casing pump in back pull-out design, withradial impeller, single-entry, single-stage, to DIN EN ISO 2858/ISO 5199.Available with cylindrical or conical shaft seal chamber.Applications:Water supply systems, dewatering systems, irrigation systems, sugar industry,alcohol industry, air-conditioning systems, building services systems, fire-fighting systems

Data for 50 Hz operation

Also available for 60 Hz

http://www.ksb.com.br/ksb-br-pt/pesquisa.php?_q=Meganorm

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

35

MegablocDNQ [m3/h]H [m]p [bar]T [°C]

25 - 160≤ 550≤ 140

≤ 16≥ 0 - ≤ +90

Description:Volute casing pump for horizontal or vertical installation, back pull-outdesign, single-stage, radially split volute casing, flanged or screw-ended(optional), replaceable casing wear rings. Volute casing with closed radialimpeller with multiply curved vanes, single mechanical seal to EN 12756.Applications:Water supply systems, irrigation systems, air-conditioning systems, buildingservices, hotels, shopping centres, etc., fire-fighting systems, cooling circuits,general industry

Data for 60 Hz operation

http://www.ksb.com.br/ksb-br-pt/pesquisa.php?_q=Megabloc

Hot water pumps

HPK-LDNQ [m3/h]H [m]p [bar]T [°C]

25 - 250≤ 1160

≤ 162≤ 40

≥ -40 - ≤ +400

Description: Horizontal radially split volute casing pump in back pull-out design toISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Equippedwith heat barrier, seal chamber air-cooled by integrated fan impeller, noexternal cooling. ATEX-compliant version available.Applications:Pumping hot water and thermal oil in piping systems or tank systems,particularly in medium-sized and large hot-water heating systems, forcedcirculation boilers, district heating systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000036

HPKDNQ [m3/h]H [m]p [bar]T [°C]

150 - 400≤ 4150

≤ 185≤ 40

≥ 0 - ≤ +400

Description:Horizontal radially split volute casing pump in back pull-out design, withradial impeller, single-entry, single-stage, to ISO 2858 / ISO 5199. OptionalTRD type testing by TÜV. ATEX-compliant version available.Applications:Pumping hot water and thermal oil in piping systems or tank systems,particularly in medium-sized and large hot-water heating systems, forcedcirculation boilers, district heating systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000034

HPHDNQ [m3/h]H [m]p [bar]T [°C]

40 - 350≤ 2350

≤ 225≤ 110

≥ 0 - ≤ +320

Description:Horizontal radially split volute casing pump in back pull-out design, withcentreline pump feet, with radial impeller, single-entry, single-stage. OptionalTRD type testing by TÜV. ATEX-compliant version available.Applications:Pumping hot water in high-pressure hot water generation plants, as boilerfeed or recirculation pump.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000037

  Pumps

  Pumps  

36

Hot water / thermal oil pumps

Etanorm SYT / RSYDNQ [m3/h]H [m]p [bar]T [°C]

25 - 300≤ 1900

≤ 102≤ 16

≥ -30 - ≤ +350

Description:Horizontal volute casing pump in back pull-out design, single-stage, withratings and dimensions to EN 733, radially split volute casing with integrallycast pump feet, replaceable casing wear rings, closed radial impeller withmultiply curved vanes, single mechanical seal to EN 12756, double mechanicalseal to EN 12756, drive-end bearings: rolling element bearings, pump-endbearings: plain bearings, with magnetless KSB SuPremE motor of efficiencyclass IE4/IE5 and PumpDrive variable speed system; ATEX-compliant versionavailable.Applications:Heat transfer systems, hot water recirculation

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000790

Etabloc SYTDNQ [m3/h]H [m]p [bar]T [°C]

25 - 80≤ 280

≤ 68≤ 16

≥ -30 - ≤ +350

Description:Volute casing pump for horizontal or vertical installation, back pull-outdesign, single-stage, with ratings to EN 733, radially split volute casing,replaceable casing wear rings, volute casing with integrally cast pump feet,closed radial impeller with multiply curved vanes, single mechanical seal toEN 12756, product-lubricated carbon plain bearing, grease-lubricated radialball bearing in the motor housing, with magnetless KSB SuPremE motor ofefficiency class IE4/IE5 and PumpDrive variable speed system, ATEX-compliantversion available.Applications:Heat transfer systems, hot water recirculation

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000791

Etaline SYTDNQ [m3/h]H [m]p [bar]T [°C]

32 - 100≤ 316

≤ 69≤ 16

≥ -30 - ≤ +350

Description:Single-stage volute casing pump in in-line design, with magnetlessKSB SuPremE motor of efficiency class IE4/IE5 and PumpDrive variable speedsystem; pump shaft and motor shaft are rigidly connected. ATEX-compliantversion available.Applications:Heat transfer systems, hot water recirculationData for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000789

Standardised chemical pumps

MegaCPKDNQ [m3/h]H [m]p [bar]T [°C]

25 - 250≤ 1160

≤ 162≤ 25

≥ -40 - ≤ +400

Description:Horizontal radially split volute casing pump in back pull-out design, withradial impeller, single-entry, single-stage, to DIN EN ISO 2858 / ISO 5199; alsoavailable as a variant with "wet" shaft and conical seal chamber. WithKSB SuPremE, a magnetless synchronous reluctance motor of efficiency classIE4/IE5 to IEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 orKSB PumpDrive 2 Eco variable speed system without rotor position sensors.Motor mounting points in accordance with EN 50347, envelope dimensions inaccordance with DIN V 42673 (07-2011). ATEX-compliant version available.Applications:Pumping aggressive liquids in the chemical and petrochemical industries andin refinery systems.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000861

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

37

CPKNDNQ [m3/h]H [m]p [bar]T [°C]

150 - 4001160 - 4150

162 - 185≤ 25

≥ -40 - ≤ +400

Description:Horizontal radially split volute casing pump in back pull-out design, withradial impeller, single-entry, single-stage, to ISO 2858 / ISO 5199. Alsoavailable as a variant with "wet" shaft, conical seal chamber and/or semi-open impeller (CPKNO). ATEX-compliant version available.Applications:Pumping aggressive liquids in the chemical and petrochemical industries,refinery systems, fire-fighting systems and for brine transport.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000027

  Pumps

  Pumps  

38

Seal-less pumps

MagnochemDNQ [m3/h]H [m]p [bar]T [°C]

25 - 250≤ 1160

≤ 162≤ 40

≥ -90 - ≤ +300

Description:Horizontal seal-less volute casing pump in back pull-out design, withmagnetic drive, radial impeller, single-entry, single-stage. Design toDIN EN ISO 2858 / ISO 5199. ATEX-compliant version available.Applications:Pumping aggressive, toxic, explosive, valuable, flammable, malodorous orharmful liquids in the chemical, petrochemical and general industries.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000046

Magnochem 685DNQ [m3/h]H [m]p [bar]T [°C]

25 - 250≤ 1160

≤ 162≤ 40

≥ -90 - ≤ +300

Description:Horizontal seal-less volute casing pump, with magnetic drive, radial impeller,single-entry, single-stage. Design to ISO 15783 / API 685 (centreline mounting,ASME flanges and permissible nozzle forces). ATEX-compliant versionavailable.Applications:Pumping aggressive, toxic, explosive, valuable, flammable, malodorous orharmful liquids in the chemical, petrochemical and general industries.

Data for 50 Hz operation

Also available for 60 Hz

Magnochem-BlocDNQ [m3/h]H [m]p [bar]T [°C]

25 - 160≤ 625≤ 162

≤ 40≥ -20 - ≤ +200

Description:Horizontal or vertical seal-less volute casing pump in close-coupled design,with magnetic drive, to DIN EN ISO 2858 / ISO 5199, with radial impeller,single-entry, single-stage. ATEX-compliant version available.Applications:Pumping aggressive, toxic, explosive, valuable, flammable, malodorous orharmful liquids in the chemical, petrochemical and general industries.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000045

Etaseco / Etaseco-IDNQ [m3/h]H [m]p [bar]T [°C]

32 - 100≤ 250≤ 100

≤ 16≥ -40 - ≤ +140

Description:Horizontal or vertical seal-less volute casing pump in back pull-out designwith fully enclosed canned motor, low noise emission, with radial impeller,single-stage, single-entry, casing connecting dimensions to EN 733, or in in-line design.Applications:Pumping aggressive, flammable, toxic, volatile or valuable liquids in thechemical and petrochemical industries, in environmental engineering andindustrial applications.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000122

Etaseco RVPDNQ [m3/h]H [m]p [bar]T [°C]

25 - 40≤ 44≤ 40≤ 16

≥ -50 - ≤ + 110

Description:Horizontal or vertical seal-less volute casing pump in back pull-out designwith fully enclosed canned motor, low noise emission, with radial impeller,single-stage, single-entry, casing connecting dimensions to EN 733, or in in-line design.Applications:Pumping toxic, volatile or valuable liquids in environmental engineering andindustrial applications and as coolant pump in cooling systems. Transportvehicles, environmental engineering and industry; applications where lownoise emission, smooth running or long service intervals are required.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000122

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

39

Process pumps

RPHDNQ [m3/h]H [m]p [bar]T [°C]

25 - 400≤ 4150

≤ 270≤ 110

≥ -70 - ≤ +450

Description:Horizontal radially split volute casing pump in back pull-out design, toAPI 610, ISO 13709 (heavy-duty), type OH2, with radial impeller, single-entry,single-stage, centreline pump feet; with inducer, if required. ATEX-compliantversion available.Applications:Refineries, petrochemical and chemical industries, power stations, offshoreand onshore processes.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000040

RPH-LFDNQ [m3/h]H [m]T [°C]

50≤ 40

≤ 339≥ -30 - ≤ +200

Description:Heavy-duty horizontal radially split process pump to API 610, ISO 13709(heavy-duty), type OH2, with axial inlet, single-stage, with normalsynchronous speed; available with different impeller sizes.Applications:Refineries, petrochemical and chemical industries.Data for 50 Hz operation

Also available for 60 Hz

RPHb / RPHdDNQ [m3/h]H [m]p [bar]T [°C]

50 - 400≤ 4500

≤ 530≤ 100

≥ -80 - ≤ +450

Description:Heavy-duty horizontal radially split between-bearings volute casing pump toAPI 610, ISO 13709 (heavy-duty), type BB2, with radial impellers, single- ordouble-entry, one- or two-stage design with centreline pump feet.Applications:Refineries, petrochemical and chemical industries, offshore and onshoreprocesses.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000041

RPH-VDN2 / DN3Q [m3/h]H [m]p [bar]T [°C]

25 - 80 / 40 - 150≤ 80

≤ 160≤ 35

≥ -30 - ≤ +230

Description:Vertical radially split volute casing pump to API 610 and ISO 13709 (heavy-duty), type VS4, with radial impeller, single-entry, single-stage.Applications:Refineries, petrochemical and chemical industries, offshore and onshoreprocesses.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000880

CTNDNQ [m3/h]H [m]p [bar]T [°C]

25 - 250 / 250 - 400≤ 950≤ 115

≤ 16≥ 0 - ≤ +300

Description:Radially split vertical shaft submersible pump with double volute casing forwet and dry installation, with radial impeller, single-entry, single-stage ordouble-stage; heatable model available. ATEX-compliant version available.Applications:Pumping chemically aggressive liquids, also slightly contaminated or with alow solids content, in the chemical and petrochemical industries.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000014

  Pumps

  Pumps  

40

CHTRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

50 - 300≤ 1450≤ 4000

≤ 400≥ -60 - ≤ +450

≤ 7000

Description:Horizontal high-pressure barrel-type pump with radial impellers, single-entryand double-entry, multistage, with flanges or weld end nozzles to DIN,API 610 and ANSI.Applications:Refineries, petrochemical industry, steam generation, seawater injection incrude oil production (onshore and offshore)

Data for 50 Hz operation

Also available for 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000241

CHTRaDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

80 - 300≤ 1200≤ 1550

≤ 155≥ -40 - ≤ +205

≤ 6000

Description:Horizontal axially split single-entry multistage between-bearings volute casingpump with single casing and back-to-back impeller arrangement to API 610(ISO 13709), type BB3. First stage optionally available in double-entry designfor low NPSH requirements. ATEX-compliant version available.Applications:Refineries, petrochemical industry, pipelines for crude oil and refineryproducts, water injection, feed water transport in power stations andindustrial plants, mining, seawater desalination, reverse osmosis.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000933

CINCP / CINCNDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

32 - 200≤ 780≤ 105

≤ 10≥ -10 - ≤ +100

≤ 3000

Description:Vertical immersion pump in cantilever design for wet or dry installation. Semi-open impeller, pump shaft without guide bearings, supported by ballbearings in the upper section. Supplied with discharge pipe extending abovethe baseplate (CINCP) or without discharge pipe (CINCN). ATEX-compliantversion available.Applications:Chemical and petrochemical industries, raw materials extraction and wastewater management.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000718

INVCPDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

32 - 300≤ 1600

≤ 116≤ 10

≥ -10 - ≤ +100≤ 3000

Description:Vertical immersion pump for wet or dry installation, available with closed orsemi-open impeller. Supplied with discharge pipe extending above thebaseplate (INVCP) or without discharge pipe (INVCN). ATEX-compliant versionavailable.Applications:Pumping chemically aggressive, slightly contaminated or solids-laden fluids inthe chemical and petrochemical industries.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000737

EstigiaDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

25 - 250≤ 1160

≤ 110≤ 16

≥ -30 - ≤ +100≤ 3000

Description:Vertical immersion pump for wet installation with closed impeller, toDIN EN ISO 5199 (with comments). Supplied with discharge pipe extendingabove the cover plate, DN according to nominal flow rate. Sealing by lip seal,single or double cartridge mechanical seal. ATEX-compliant version available.Applications:Pumping chemically aggressive, slightly contaminated or solids-laden fluids inthe chemical and petrochemical industries.Data for 50 Hz operation

Also available for 60 Hz

PumpDrive, Frequency inverter, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000937

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

41

RWCP / RWCNDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

50 - 200≤ 700≤ 100

≤ 16≥ -10 - ≤ +100

≤ 3000

Description:Process pump with free-flow impeller, semi-open or two-channel or three-channel impeller. Shaft sealed by mechanical seal or gland packing inaccordance with various API pipework plans. Oil-lubricated bearings. ATEX-compliant version available.Applications:Refineries, chemical and petrochemical industries, steel works, descaling units,raw materials extraction, waste water management.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000748

WKTRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

40 - 150≤ 400≤ 500

≤ 51≥ -40 - ≤ +200

≤ 3000

Description:Vertical can-type ring-section pump. Type VS6 to API 610 and DIN ISO 13709,multistage, first-stage impeller designed as suction impeller, radial impellers.ATEX-compliant version available.Applications:Pumping condensate and other NPSH-critical products in industrial plants,particularly in refineries and petrochemical plants.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000875

  Pumps

  Pumps  

42

Rainwater harvesting systems

Hya-Rain / Hya-Rain NRpQ [m3/h]H [m]p [bar]T [°C]

1≤ 4

≤ 43≤ 6

≥ 0 - ≤ +35

Description:Ready-to-connect package rainwater harvesting system in protective housingwith automatic mains water back-up function if the rainwater storage tank isempty, with integrated dry running protection and demand-driven automaticpump control. Hya-Rain N version with analog level measurement inrainwater storage tank and integrated functional check run.Applications:Rainwater harvesting and service water harvesting, irrigation and sprayirrigation systems.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000256

Hya-Rain EcoRpQ [m3/h]H [m]p [bar]T [°C]

1≤ 4

≤ 43≤ 6

≥ 0 - ≤ +35

Description:Basic ready-to-connect package rainwater harvesting system with automaticmains water back-up function if the rainwater storage tank is empty, withintegrated dry running protection and demand-driven automatic pumpcontrol.Applications:Rainwater harvesting and service water harvesting, irrigation and sprayirrigation systems.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000600

Domestic water supply / swimming pool pumps

Emporia CPRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1≤ 7,5≤ 55

≤ 8≥ 0 - ≤ +90

≤ 2800

Description:Single-stage centrifugal pump in close-coupled design, extremely quietoperation, for use in domestic, public and industrial applicationsApplications:Spray irrigation systems, general irrigation systems, water supply systems

Data for 50 Hz operation

Control unit http://shop.ksb.com/catalog/k0/en/product/ES000921

Emporia MBRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 - 1 1/2≤ 15≤ 90≤ 10

≥ 0 - ≤ +90≤ 2800

Description:Multistage centrifugal pump, with 2 impellers, for use in public and industrialapplicationsApplications:Spray irrigation systems, general irrigation systems, water supply systems

Data for 50 Hz operation

Control unit http://shop.ksb.com/catalog/k0/en/product/ES000922

Emporia PDRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1≤ 3

≤ 55≤ 8

≥ 0 - ≤ +90≤ 2800

Description:Peripheral impeller pump in close-coupled design for domestic applicationsApplications:Spray irrigation systems, general irrigation systems, water supply systems

Data for 50 Hz operation

Control unit http://shop.ksb.com/catalog/k0/en/product/ES000923

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

43

Multi EcoRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 - 1 1/4≤ 8

≤ 54≤ 10

≥ +4 - ≤ +50≤ 2800

Description:Multistage self-priming centrifugal pump in close-coupled design.Applications:Single- or two-family houses, agricultural facilities, spray irrigation systems,irrigation systems and washing plants, water supply and rainwater harvesting.

Data for 50 Hz operation

Cervomatic, Controlmatic http://shop.ksb.com/catalog/k0/en/product/ES000085

Multi Eco-ProRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 - 1 1/4≤ 8

≤ 54≤ 10

≥ +4 - ≤ +50≤ 2800

Description:Multistage self-priming centrifugal pump in close-coupled design, with powercable, plug and Controlmatic E automatic control unit for starting andstopping the pump in line with consumer demand and protecting it againstdry running. Automated with automatic control unit.Applications:Single- or two-family houses, agricultural facilities, spray irrigation systems,irrigation systems and washing plants, water supply and rainwater harvesting.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000253

Multi Eco-TopRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 - 1 1/4≤ 8

≤ 54≤ 10

≥ +4 - ≤ +50≤ 2800

Description:Multistage self-priming centrifugal pump in close-coupled design incl.accumulator with replaceable membrane in drinking water quality, totalvolume 20 or 50 litres, pressure switch for automatic pump operation and 1.5-metre power cable with plug.Applications:Single- or two-family houses, agricultural facilities, spray irrigation systems,irrigation systems and washing plants, water supply and rainwater harvesting.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000254

Ixo NRpQ [m3/h]H [m]T [°C]n [rpm]

1 1/4≤ 8

≤ 65≥ +5 - ≤ +35

≤ 2900

Description:Multistage close-coupled centrifugal pump for fully or partly submergedoperation (min. immersion depth 0.1 m), with low-level inlet, suction strainerwith a max. mesh width of 2.0 mm.Applications:Water supply systems, spray irrigation systems, irrigation systems, washingplants, rainwater harvesting and water extraction from wells, reservoirs andrainwater storage tanks

Data for 50 Hz operation

Control unit, Cervomatic http://shop.ksb.com/catalog/k0/en/product/ES000007

Ixo-ProRpQ [m3/h]H [m]T [°C]

1≤ 3,9≤ 60

≥ +5 - ≤ +35

Description:Multistage submersible borehole pump with integrated pressure switch, flowsensor and lift check valve. Electronic dry running protection with fourconsecutive start-up attempts; integrated capacitor. 15-metre H07 RNF powercable with plug included.Applications:Rainwater harvesting, pressure boosting, water extraction, irrigation systems

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000896

  Pumps

  Pumps  

44

Filtra NRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

2≤ 36≤ 21≤ 2,5

≥ +4 - ≤ +35≤ 2800

Description:Single-stage self-priming centrifugal pump in close-coupled design.Applications:Pumping clean or slightly contaminated water, swimming pool water with amax. chlorine content of 0.3 %; ozonised swimming pool water with a max.salt content of 7 ‰.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000090

Pressure booster systems

KSB Delta Compact MVPRpQ [m3/h]H [m]p [bar]T [°C]

1 / 1 1/2≤ 18≤ 57≤ 10

≥ 0 - ≤ +40

Description:Fully automatic, ready-to-connect package single-pump pressure boostersystem / dual-pump pressure booster system with variable speed systemApplications:Domestic water supply, water supply systems, spray irrigation systems, generalirrigation systems, service water systems, rainwater harvesting

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000940

KSB Delta Eco MVP/SVPRpQ [m3/h]H [m]p [bar]T [°C]

1 1/2≤ 65,4≤ 134

≤ 16≥ 0 - ≤ +60

Description:Fully automatic pressure booster system with either two or three verticalhigh-pressure pumps in two variable speed versions. The frequency inverteroperated MVP and SVP versions ensure variable speed control of each pumpby motor-mounted frequency inverter for asynchronous motors (MVP) orPumpDrive variable speed system and KSB SuPremE motor (SVP), respectively,providing fully electronic control to ensure the required supply pressure.Equipped with a central fuse box.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industry, etc.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000942

KSB Delta Primo K/VP/SVPRpQ [m3/h]H [m]p [bar]T [°C]

1 1/2≤ 67,5≤ 134

≤ 16≥ 0 - ≤ +60

Description:Fully automatic package pressure booster system with either two or threevertical high-pressure pumps; available in cascade-controlled and two variablespeed versions. Cascade (K) control for ensuring the required supply pressure.The frequency inverter operated VP and SVP versions ensure variable speedcontrol of each pump via cabinet-mounted frequency inverter (VP) orPumpDrive variable speed system and KSB SuPremE motor (SVP), respectively,providing fully electronic control to ensure the required supply pressure.Automated with BoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industry, etc.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000941

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

45

KSB Delta Solo MVP/SVPRpQ [m3/h]H [m]p [bar]T [°C]

1 1/4≤ 21,8≤ 134

≤ 16≥ 0 - ≤ +60

Description:Fully automatic single-pump system available in two variable speed versions.The frequency inverter operated MVP and SVP versions ensure variable speedcontrol of the pump by motor-mounted frequency inverter for asynchronousmotors (MVP) or PumpDrive variable speed system and KSB SuPremE motor(SVP), respectively, providing fully electronic control to ensure the requiredsupply pressure.Applications:Water supply systems for residential buildings and office buildings, irrigationsystems and rainwater harvesting systems, service water supply systems, intrade and industry.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000939

Hya-Solo DRpDNQ [m3/h]H [m]p [bar]T [°C]

1100

≤ 110≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package single-pump system with 8-litre membrane-typeaccumulator. The system is started and stopped as a function of pressure.Applications:Water supply systems for residential and office buildings, irrigation and sprayirrigation, rainwater harvesting and service water supply systems in trade andindustry.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000250

Hya-Solo DSVRpDNQ [m3/h]H [m]p [bar]T [°C]

1100

≤ 110≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic variable speed package single-pump system withPumpDrive 2 / PumpDrive 2 Eco. The system is started as a function of pressureand stopped as a function of flow.Applications:Water supply systems for residential and office buildings, irrigation and sprayirrigation, rainwater harvesting and service water supply systems in trade andindustry.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000251

Hya-Solo D FLRpDNQ [m3/h]H [m]p [bar]T [°C]

1100

≤ 110≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package single-pump system. The system is started andstopped as a function of pressure. Design and function as per DIN 14462.Applications:Fire-fighting systems to DIN 14462

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000709

Hya-Duo D FLRpDNQ [m3/h]H [m]p [bar]T [°C]

2150

≤ 110≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package dual-pump system consisting of one duty system andone stand-by system to ensure system redundancy. Design and function as perDIN 14462.Applications:Fire-fighting systems to DIN 14462

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000710

  Pumps

  Pumps  

46

Hya-Solo D FL CompactDNQ [m3/h]H [m]p [bar]T [°C]

50 - 80≤ 48

≤ 160≤ 16

≥ 0 - ≤ +70

Description:Fully automatic ready-to-connect break tank package booster set for firefighting, comprising a single-pump system and break tank. The system isstarted and stopped as a function of pressure. Design and function as perDIN 14462.Applications:Fire-fighting systems to DIN 14462Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000821

Hya-Duo D FL CompactDNQ [m3/h]H [m]p [bar]T [°C]

50 - 80≤ 48

≤ 160≤ 16

≥ 0 - ≤ +70

Description:Fully automatic, ready-to-connect break tank package booster set for firefighting, comprising a dual-pump system and break tank. The system isstarted and stopped as a function of pressure. Design and function as per DIN14462.Applications:Fire-fighting systems to DIN 14462Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000820

Hyamat KRpDNQ [m3/h]H [m]p [bar]T [°C]

2250

≤ 660≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package pressure booster system with 2 to 6 vertical high-pressure pumps and fully electronic control to ensure the required supplypressure, with volt-free changeover contact for general fault indication andlive-zero monitoring of the connected sensors, design and function toDIN 1988. Automated with BoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industry, etc.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000247

Hyamat VRpDNQ [m3/h]H [m]p [bar]T [°C]

2250

≤ 660≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package pressure booster system with 2 to 6 vertical high-pressure pumps and continuously variable speed adjustment of one pump; forfully electronic control of the required supply pressure. Design and functionas per DIN 1988. Automated with BoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industry, etc.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000417

Hyamat SVPRpDNQ [m3/h]H [m]p [bar]T [°C]

2250

≤ 660≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package pressure booster system with 2 to 6 vertical high-pressure pumps and continuously variable speed adjustment of all pumps byPumpDrive; for fully electronic control of the required supply pressure. Designand function as per DIN 1988. Automated with BoosterControl andPumpDrive.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industry, etc.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000418

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

47

Hyamat SVP ECORpDNQ [m3/h]H [m]p [bar]T [°C]

2250

≤ 660≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package pressure booster system with 2 to 6 vertical high-pressure pumps and continuously variable speed adjustment of all pumps byPumpDrive; for fully electronic control of the required supply pressure. Designand function as per DIN 1988. Automated with PumpDrive.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industry, etc.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000935

Surpresschrom SIC.2RpDNQ [m3/h]H [m]p [bar]T [°C]

2250

≤ 660≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package pressure booster system with 2 to 6 vertical high-pressure pumps, with fully electronic control system ensuring the requiredsupply pressure, with standard volt-free changeover contact for general faultindication and live-zero monitoring of the connected sensors. Automatedwith BoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industrial plants, etc.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000439

Surpresschrom SIC.2 VRpDNQ [m3/h]H [m]p [bar]T [°C]

2250

≤ 660≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package pressure booster system with 2 to 6 vertical high-pressure pumps. Continuously variable speed adjustment of one pump withPumpDrive for fully electronic control of the required supply pressure.Automated with BoosterControl and PumpDrive.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industrial plants, etc.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000702

Surpresschrom SIC.2 SVPRpDNQ [m3/h]H [m]p [bar]T [°C]

2250

≤ 660≤ 160

≤ 16≥ 0 - ≤ +70

Description:Fully automatic package pressure booster system with 2 to 6 vertical high-pressure pumps. Continuously variable speed adjustment of all pumps withPumpDrive for fully electronic control of the required supply pressure.Automated with BoosterControl and PumpDrive.Applications:Pressure boosting in residential buildings, hospitals, office buildings, hotels,department stores, industrial plants, etc.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000701

Surpress Feu SFERpQ [m3/h]H [m]p [bar]T [°C]

2 1/2≤ 40≤ 76≤ 10

≥ 0 - ≤ +70

Description:Fully automatic pressure booster system with two horizontal close-coupledpumps (one pump on stand-by duty). Design complies with APSADregulation R5. Pressure-controlled starting and stopping. Automated withBoosterControl.Applications:Water supply and pressure boosting for wall hydrants, fire protection.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000441

  Pumps

  Pumps  

48

Drainage pumps / waste water pumps

Ama-Drainer NRpQ [m3/h]H [m]T [°C]

1 1/4 - 1 1/2≤ 16,5

≤ 12≥ 0 - ≤ +50

Description:Vertical single-stage fully floodable submersible motor pump in close-coupleddesign, IP68, with or without level control, max. immersion depth: 2 m.Applications:Automatic drainage of pits, shafts, yards and cellars at risk of flooding,lowering of surface water levels, drainage, drainage of undergroundpassages, water extraction from rivers and reservoirs.

Data for 50 Hz operation

Also available for 60 Hz

Control unit, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000771

Ama-Drainer 4../5..RpQ [m3/h]H [m]T [°C]

1 1/2 - 2≤ 50≤ 24

≥ 0 - ≤ +40

Description:Vertical single-stage fully floodable submersible motor pumps in close-coupled design, IP68, with or without level control, max. immersion depth:7 m.Applications:Automatic drainage of pits, shafts, yards and cellars at risk of flooding,lowering of surface water levels, drainage, drainage of undergroundpassages, water extraction from rivers and reservoirs.

Data for 50 Hz operation

Also available for 60 Hz

Control unit, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000078

Ama-Drainer 80, 100RpDNQ [m3/h]H [m]T [°C]

2 1/2100

≤ 130≤ 26

≥ 0 - ≤ +50

Description:Vertical single-stage fully floodable submersible motor pump in close-coupleddesign, IP68, with or without level control, max. immersion depth: 10 m.Applications:Automatic drainage of pits, shafts, yards and cellars at risk of flooding,lowering of surface water levels, drainage, drainage of undergroundpassages, water extraction from rivers and reservoirs.Data for 50 Hz operation

Also available for 60 Hz

Control unit, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000079

Ama-Porter F / SDNQ [m3/h]H [m]T [°C]

50 - 65≤ 40≤ 16

≤ +40

Description:Vertical single-stage fully floodable submersible waste water pump in close-coupled design (grey cast iron variant), non-explosion-proof.Applications:Handling waste water, especially waste water containing long fibres and solidsubstances, fluids containing gas/air, removing waste water from floodedrooms or surfaces.

Data for 50 Hz operation

Control unit, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000082

RotexRpQ [m3/h]H [m]T [°C]n [rpm]Inst. depth [m]

1 1/4 - 2≤ 24≤ 14

≥ 0 - ≤ +90≤ 2900

≤ 1,7

Description:Vertical single-stage centrifugal pump with discharge to the top and parallelwith the pump shaft, pump base designed to act as suction strainer. Pumpand motor are rigidly connected by a support column. Supplied ready to beplugged in, with 1.5-metre power cable and level switch.Applications:Automatic drainage of buildings, pits and tanks, lowering of surface waterlevels and drainage.Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000012

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

49

MK / MKYRpDNQ [m3/h]H [m]T [°C]n [rpm]Inst. depth [m]

250

≤ 36≤ 19

≥ -10 - ≤ +200≤ 3500

≤ 2,8

Description:Vertical submersible pump with three-channel impeller, volute casingdesigned as inlet strainer.Applications:Pumping condensate and heat transfer fluids below boiling point, condensatereturn systems, primary and secondary heating circuits, for direct installationin heating tanks or heat exchangers in the secondary circuits of heat transfersystems (MKY).

Data for 50 Hz operation

Also available for 60 Hz

Control unit, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000013

Lifting units / package pump stations

AmacleanQ [m3/h]H [m]T [°C]

≤ 150≤ 62

depending onpump

Description:Self-cleaning tank insert for grouted installation in new concrete structures orin concrete structures in need of refurbishment. Designed to prevent soilingof the structure and clogging of the pumps by heavily waste or fibre loadedwaste water. Suitable for pump stations emitting unpleasant odours and/orgases.Applications:Waste water disposal, rainwater disposal

http://shop.ksb.com/catalog/k0/en/product/ES000936

AmaDS³Q [m3/h]H [m]T [°C]

≤ 200≤ 85

depending onpump

Description:Waste water pump station with solids separation system. Indirect hydraulictransport of waste water, solids separators arranged upstream of the pumps,for maximum economic efficiency, operating reliability and ease of servicing.Applications:Municipal and industrial waste water transport. Applications with specialdrainage requirements, e.g. hotels, hospitals, campgrounds, etc.

Data for 50 Hz operation

Also available for 60 Hz

LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000858

Ama-Drainer-Box MiniDNQ [m3/h]H [m]T [°C]

40≤ 10≤ 6,5

≤ +50

Description:Reliable and compact waste water lifting unit in a modern design withactivated carbon filter meeting hygiene requirements and with showerconnection as standard; complies with EN 12050-2Applications:Automatic disposal of waste water from washbasins, showers, washingmachines and dishwashers. Use mini-Compacta sewage lifting unit forhandling sewage from urinals and toilets.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000862

Ama-Drainer-BoxDNQ [m3/h]H [m]T [°C]

40 - 50≤ 46≤ 24

≤ +40

Description:Stable above-floor plastic collecting tank or impact-resistant underfloorplastic collecting tank, with floor drain and odour trap, both with Ama-Drainer submersible motor pump starting and stopping automatically andswing check valveApplications:Automatic disposal of waste water from washbasins, showers, washingmachines, garage driveways, basements and rooms prone to flooding

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000262

  Pumps

  Pumps  

50

Evamatic-Box NDNQ [m3/h]H [m]T [°C]

50 - 65≤ 40≤ 21

≤ +40

Description:Floodable lifting unit for domestic waste water, equipped with either one ortwo pumps of type Ama-Porter F (free-flow impeller) or Ama-Porter S (cutter)Applications:Disposal of domestic and municipal waste water occurring below the floodlevelData for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000430

mini-CompactaDNQ [m3/h]H [m]T [°C]

32 - 100≤ 36≤ 25

≤ +40

Description:Floodable single-pump sewage lifting unit or dual-pump sewage lifting unitfor automatic disposal of domestic sewage and faeces in building sectionsbelow the flood level.Applications:Basement flats, bars, basement party rooms and saunas, cinemas and theatres,department stores, hospitals, hotels, restaurants or schools.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000261

CompactaDNQ [m3/h]H [m]T [°C]

80 - 100≤ 140≤ 24,5≤ +40

Description:Floodable single-pump sewage lifting unit or dual-pump sewage lifting unitfor automatic disposal of waste water and faeces in buildings and buildingsections below the flood level.Applications:Basement flats, bars, basement party rooms and saunas, cinemas and theatres,department stores and hospitals, hotels, restaurants, schools, other publicbuildings, industrial facilities, underground train stations or for joint sewagedisposal from rows of houses.

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000260

CK 800 Pump StationDNQ [m3/h]H [m]T [°C]

32 - 50≤ 22≤ 49

≤ +40

Description:Single-pump or dual-pump station as ready-to-connect package system, withPE-LLD (polyethylene) collecting tank for buried installation. Equipped witheither one or two submersible waste water pumps of type Amarex N S(explosion-proof or non-explosion-proof) or Ama-Porter (non-explosion-proof). Tank design to DIN 1986-100 and EN 752/EN 476.Applications:Drainage of buildings and premises, waste water disposal, premisesrenovation, joint sewage disposal for multiple residential units, pumpeddrainage

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000778

CK 1000 Pump StationDNQ [m3/h]H [m]T [°C]

50 - 65≤ 50≤ 39

≤ +40

Description:Single-pump or dual-pump station as ready-to-connect package system, withPE-LLD (polyethylene) collecting tank for buried installation. Equipped witheither one or two submersible waste water pumps of type Amarex N(explosion-proof or non-explosion-proof) or Ama-Porter (non-explosion-proof). Tank design to DIN 1986-100 and EN 752/EN 476.Applications:Drainage of buildings and premises, waste water disposal, premisesrenovation, joint sewage disposal for multiple residential units, pumpeddrainage

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000266

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

51

Ama-Porter CK Pump StationDNQ [m3/h]H [m]T [°C]

50 - 65≤ 40≤ 16

≤ +40

Description:Single-pump or dual-pump station as ready-to-connect package system, withPE-LLD (polyethylene) collecting tank for buried installation. Equipped witheither one or two submersible waste water pumps of type Ama-Porter (non-explosion-proof). Tank design to DIN 1986-100 and EN 752/EN 476.Applications:Drainage of buildings and premises, waste water disposal, premisesrenovation, joint sewage disposal for multiple residential units, pumpeddrainage

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000498

SRPDNQ [m3/h]H [m]T [°C]

50 - 150≤ 500

≤ 75≤ +40

Description:Single-pump or dual-pump station as ready-to-connect package system, withfibreglass collecting tank for buried installationApplications:Premises renovation, disposal of domestic, municipal and industrial wastewater, joint sewage disposal for multiple residential unitsData for 50 Hz operation

Also available for 60 Hz

Control unit, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000443

SRLDNQ [m3/h]H [m]T [°C]

65 - 150≤ 500

≤ 55≤ +40

Description:Package pump station with tank made of glass fibre reinforced polyester,equipped with two Sewabloc pumps with a rating of 2.2 to 30 kW in dryinstallation, integrated valves and a control unit with frequency inverters.Pump operation is adjusted in line with flow rate demand, thus minimisingenergy costs. This maintenance-friendly pump station prevents intermediatestorage of waste water and the related odour nuisance.Applications:Joint disposal of domestic, municipal and industrial waste water to the sewersystem / sewage treatment plant

Data for 50 Hz operation

http://shop.ksb.com/catalog/k0/en/product/ES000856

SRSDNQ [m3/h]H [m]T [°C]

50 - 65≤ 50≤ 49

≤ +40

Description:Package pump station with tank made of glass fibre reinforced polyester forunderfloor installation and two submersible waste water pumps mounted onduckfoot bends, with two guide systems. Complete discharge line made ofPVC with ball valves and ball non-return valves fitted in the tank.Applications:Stormwater disposal, grey water disposal, waste water disposal

Data for 50 Hz operation

Also available for 60 Hz

LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000773

  Pumps

  Pumps  

52

Submersible motor pumps

Amarex NDNQ [m3/h]H [m]T [°C]

32 - 100≤ 190

≤ 49≤ +40

Description:Vertical single-stage submersible motor pump for wet installation, with cutter(S), free-flow impeller (F) or diagonal single-vane impeller (D), stationary ortransportable version. Amarex N pumps are floodable, single-stage, single-entry close-coupled pump sets which are not self-priming. ATEX-compliantversion available.Applications:Pumping waste water, especially untreated waste water containing longfibres and solid substances, fluids containing gas or air, and raw, activatedand digested sludge; for dewatering and water extraction, drainage of roomsand areas at risk of flooding.

Data for 50 Hz operation

Also available for 60 Hz

Control unit, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000507

Amarex KRTDNQ [m3/h]H [m]T [°C]n [rpm]

40 - 700≤ 10080

≤ 120≤ +60

≤ 2900

Description:Horizontal or vertical single-stage submersible motor pump in close-coupleddesign, with various next-generation impeller types, for wet or dryinstallation, stationary or transportable version, with energy-saving motorand models for use in potentially explosive atmospheres.Applications:Pumping all types of waste water in water and waste water management,seawater desalination and industry, especially untreated waste watercontaining long fibres and solid substances, fluids containing gas or air, andraw, activated and digested sludge.

Data for 50 Hz operation

Also available for 60 Hz

PumpDrive, Amacontrol, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000092

Submersible pumps in discharge tubes

Amacan KDNQ [m3/h]H [m]T [°C]n [rpm]

700 - 1400≤ 5400

≤ 30≥ 0 - ≤ +40

≤ 980

Description:Wet-installed submersible motor pump for installation in discharge tubes,with channel impeller, single-stage, single-entry. ATEX-compliant versionavailable.Applications:Pumping pre-cleaned chemically neutral waste water, industrial effluent,sewage, fluids not containing any stringy substances, pre-treated by screensand overflow sills; as waste water, mixed sewage and activated sludge pumpsin waste water treatment plants, irrigation and drainage pumping stations.

Data for 50 Hz operation

Also available for 60 Hz

Amacontrol http://shop.ksb.com/catalog/k0/en/product/ES000100

Amacan PDNQ [m3/h]H [m]T [°C]n [rpm]

500 - 1500≤ 25200

≤ 12≥ 0 - ≤ +40

≤ 1450

Description:Wet-installed submersible motor pump for installation in discharge tubes,with axial propeller in ECB design, single-stage, single-entry. ATEX-compliantversion available.Applications:Irrigation and drainage pumping stations, for stormwater transport instormwater pumping stations, raw and clean water transport in water andwaste water treatment plants, cooling water transport in power stations andindustrial plants, industrial water supply, water pollution and flood control,aquaculture.

Data for 50 Hz operation

Also available for 60 Hz

Amacontrol http://shop.ksb.com/catalog/k0/en/product/ES000099

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

53

Amacan SDNQ [m3/h]H [m]T [°C]n [rpm]

650 - 1300≤ 10800

≤ 40≥ 0 - ≤ +40

≤ 1450

Description:Wet-installed submersible motor pump for installation in discharge tubes,with mixed flow impeller, single-stage. ATEX-compliant version available.Applications:Pumping water not containing stringy material in irrigation and drainagepumping stations, general water supply systems, water pollution and floodcontrol.Data for 50 Hz operation

Also available for 60 Hz

Amacontrol http://shop.ksb.com/catalog/k0/en/product/ES000101

  Pumps

  Pumps  

54

Mixers / agitators / tank cleaning units

AmamixPropeller Ø [mm]T [°C]n [rpm]Inst. depth [m]

200 - 600≥ 0 - ≤ +40

≤ 1400≤ 30

Description:Horizontal submersible mixer with self-cleaning ECB propeller, close-coupleddesign, direct drive. ATEX-compliant version available.Applications:Handling municipal and industrial waste water and sludges in environmentalengineering (also in biogas plants).Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000268

AmapropPropeller Ø [mm]T [°C]n [rpm]Inst. depth [m]

1000 - 2500≥ 0 - ≤ +45

≤ 109≤ 30

Description:Horizontal submersible mixer with self-cleaning ECB propeller, close-coupleddesign, with coaxial spur gear drive. ATEX-compliant version available.Applications:In environmental engineering, particularly in municipal and industrial wastewater and sludge treatment, for circulating, keeping in suspension andinducing flow in nitrification tanks and denitrification tanks, activated sludgetanks, biological phosphate elimination tanks, flocculation tanks and sludgestorage tanks

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000271

AmajetDNQ [m3/h]T [°C]n [rpm]

100 - 150≤ 195

≥ +4 - ≤ +40≤ 1450

Description:Stationary or portable unit with horizontally or vertically mountedsubmersible propulsive jet pump with non-clogging free-flow impeller. Motorratings of 5.5 to 27 kW. Available variants: Amajet, SewerAmajet,SwingAmajet, MultiAmajet.Applications:Cleaning stormwater tanks and storage sewers.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000097

AmalineDNQ [m3/h]H [m]T [°C]n [rpm]

300 - 800≤ 5400

≤ 2≥ 0 - ≤ +40

≤ 960

Description:Wet-installed horizontal propeller pump with submersible motor, equippedwith direct drive or spur gear, ECB propeller with three rigid, fibre-repellentblades, bolt-free connection to the discharge pipe. ATEX-compliant versionavailable.Applications:Recirculating activated sludge in waste water treatment systems.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000273

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

55

Pumps for solids-laden fluids

SewatecDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

50 - 700≤ 10000

≤ 115≤ 10

≤ +70≤ 2900

Description:Volute casing pump for horizontal or vertical installation, with free-flow (F),single-channel (E), multi-channel (K) or diagonal single-vane impeller (D),discharge flange to DIN and ANSI standards. ATEX-compliant versionavailable.Applications:Waste water transport, waste water disposal, waste water management,transport of contaminated surface water, sludge treatmentData for 50 Hz operation

Also available for 60 Hz

PumpDrive, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000068

Sewatec SPNDNQ [m3/h]H [m]p [bar]T [°C]

≤ 1200≤ 32400

≤ 115≤ 16

≤ +70

Description:Vertical volute casing pump with multi-channel impellers (K), discharge flangeto DIN and ANSI standards.Applications:Waste water transport, waste water disposal, waste water management,transport of contaminated surface water

Data for 50 Hz operation

Also available for 60 Hz

SewablocDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

50 - 200≤ 10000

≤ 90≤ 10

≤ +70≤ 2900

Description:Close-coupled volute casing pump for horizontal or vertical installation, withfree-flow (F), multi-channel (K) or diagonal single-vane impeller (D), dischargeflange to DIN and ANSI standards. ATEX-compliant version available.Applications:Waste water transport, waste water disposal, waste water management,transport of contaminated surface water, sludge treatment

Data for 50 Hz operation

Also available for 60 Hz

PumpDrive, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000069

KWPDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

40 - 900≤ 15000

≤ 100≤ 10

≥ -40 - ≤ +140≤ 2900

Description:Horizontal radially split volute casing pump in back pull-out design, single-stage, single-entry, available with various impeller types: closed multi-channelimpeller, open multi-vane impeller and free-flow impeller. ATEX-compliantversion available.Applications:Paper industry, cellulose industry, sugar industry, food industry, power plants,chemical industry, petrochemical industry, flue gas desulphurisation, coalupgrading plants, industrial applications, waste water transport, seawaterdesalination / reverse osmosis

Data for 50 Hz operation

Also available for 60 Hz

PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000018

KWP-BlocDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

40 - 900≤ 325≤ 100

≤ 10≥ -40 - ≤ +100

≤ 2900

Description:Horizontal or vertical radially split close-coupled casing pump, single-stage,single-entry, available with various impeller types: closed multi-channelimpeller, open multi-vane impeller and free-flow impeller.Applications:Paper industry, cellulose industry, sugar industry, food industry, chemicalindustry, petrochemical industry, flue gas desulphurisation, industrialapplications, waste water transportData for 50 Hz operation

Also available for 60 Hz

PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000020

  Pumps

  Pumps  

56

Slurry pumps

WBCQ [m3/h]H [m]p [bar]T [°C]

≤ 16200≤ 80≤ 32

≥ -20 - ≤ +120

Description:Patented design with state-of-the-art hydraulic and wear technologies forhigh-pressure applications. The pump casing is designed to withstandmaximum stresses, e.g. during pressure surges.Applications:Ideal for the single-stage or multistage transport of ore and tailings and fordredging.

http://shop.ksb.com/catalog/k0/en/product/ES000227

LSA-SQ [m3/h]H [m]p [bar]T [°C]

≤ 18000≤ 150

≤ 17≥ -20 - ≤ +120

Description:Premium design white cast iron pump for long service life handling severeslurries. The maintenance-friendly single-wall construction and heavy sectionwhite cast iron wet end combined with the cartridge bearing assemblyprovides maximum reliability and ease of maintenance.Applications:Ore and tailings transport, cyclone feed, dredging (dry-installed or submergedoperation) and industrial processes.

http://shop.ksb.com/catalog/k0/en/product/ES000220

LCC-MQ [m3/h]H [m]p [bar]T [°C]

≤ 3200≤ 90≤ 16

≤ +120

Description:The wetted pump end (casing, impeller and suction plate / liner) is made ofwhite cast iron. Design optimised to permit easy dismantling and reassemblyfor maintenance and inspections.Applications:Reliable pump for high heads and moderately corrosive slurries. Used in minedewatering, ash and tailings transport and dredging.

http://shop.ksb.com/catalog/k0/en/product/ES000217

LCC-RQ [m3/h]H [m]p [bar]T [°C]

≤ 2560≤ 42≤ 16

≤ +65

Description:Interchangeable rubber-lined or part-metal design allows adaptation ofexisting pumps to new applications by simply exchanging the pump wet end.Applications:The pumps are suitable for moderate heads, fine particles and highlycorrosive slurries.

http://shop.ksb.com/catalog/k0/en/product/ES000218

TBCQ [m3/h]H [m]p [bar]T [°C]

≤ 18200≤ 90≤ 37

≥ -20 - ≤ +120

Description:Horizontal high-pressure end-suction centrifugal pump offering maximumresistance to wear and ease of maintenance. The conventional single-walldesign transfers stress loads from the wear plates to the casing covers in high-pressure applications. Pump components made of highly wear-resistant whitecast iron.Applications:High-head high-flow hydrotransport of tailings, dredged material, pipelinebooster stations and other severe duties.

http://shop.ksb.com/catalog/k0/en/product/ES000226

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

57

LCVQ [m3/h]H [m]p [bar]T [°C]

≤ 2045≤ 38≤ 14

≤ +120

Description:Rugged vertical shaft submersible pump with casing, impeller and suctionplate / liner made of white cast iron, bearing assembly located out of product.Replaceable wetted parts made of white cast iron or natural rubber.Applications:Particularly suitable for use in industrial processes and for transportingtailings in mines and pits.

http://shop.ksb.com/catalog/k0/en/product/ES000016

FGDQ [m3/h]H [m]p [bar]T [°C]

≤ 23000≤ 30≤ 10

≥ -20 - ≤ +120

Description:High-flow / low-head white cast iron pump with single-wall casing and high-efficiency impeller. Single-piece suction cover with integrated mountingplate.Applications:Flue gas desulpurisation systems and process circuits

http://shop.ksb.com/catalog/k0/en/product/ES000231

MHDQ [m3/h]H [m]p [bar]T [°C]

≤ 90000≤ 115

≤ 13≥ -20 - ≤ +120

Description:Horizontal volute casing pump for high-volume hydrotransport of solids. Forpumping slurries of large and very large particle sizes with a very goodsuction behaviour and high efficiency. Pump components made of white castiron.Applications:Ideal for pipeline pressure booster stations and severe mining duties. Highlysuitable for loading and unloading duties on (cutter) suction dredgers.

http://shop.ksb.com/catalog/k0/en/product/ES000224

LHDQ [m3/h]H [m]p [bar]T [°C]

≤ 30000≤ 105

≤ 15≥ -20 - ≤ +120

Description:Horizontal volute casing pump for high-volume hydrotransport of solids. Forpumping slurries of large and very large particle sizes with a very goodsuction behaviour and high efficiency. Used in low-pressure applications.Pump components made of white cast iron.Applications:Ideal for handling sand and gravel, on dredgers for land reclamation and asbooster pumps.

http://shop.ksb.com/catalog/k0/en/product/ES000223

MDXQ [m3/h]H [m]p [bar]T [°C]

≤ 14000≤ 90≤ 16

≥ -20 - ≤ +120

Description:Pump designed with the latest technology from GIW. Superior wearproperties and extremely long service life handling aggressive slurries.Applications:Designed for SAG and ball mill discharge duties, cyclone feed, screen feed andother ore mining and treatment processes.

http://shop.ksb.com/catalog/k0/en/product/ES000850

  Pumps

  Pumps  

58

ZWQ [m3/h]H [m]p [bar]T [°C]

≤ 400≤ 35≤ 10

≥ 0 - ≤ +65

Description:Rugged vertical shaft submersible pump with casing, impeller and suctioncover made of white cast iron, top and bottom impeller inlet. Bearings notexposed to fluid handled. Replaceable wetted components.Applications:Particularly suitable for pumping abrasive slurries, dewatering, floor clean-upand process applications.

http://shop.ksb.com/catalog/k0/en/product/ES000852

HVFQ [m3/h]H [m]p [bar]T [°C]

≤ 7200≤ 50≤ 11

≤ +120

Description:The pump provides continuous operation without shutdown or operatorintervention. The new hydraulic design removes air from the impeller eyewhile the pump is running, and the pump can be retrofitted into any existingoperation.Applications:For use in all froth pumping applications in the mineral processing andindustrial minerals industries.

http://shop.ksb.com/catalog/k0/en/product/ES000851

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

59

Self-priming pumps

Etaprime LDNQ [m3/h]H [m]p [bar]T [°C]Hgeo [m]

25 - 125≤ 180

≤ 85≤ 10

≥ -30 - ≤ +90≤ 9

Description:Horizontal self-priming volute casing pump, single-stage, with open multi-vane impeller, from size 40-40-140 with bearing bracket, in back pull-outdesign, ATEX-compliant version available.Applications:Pumping clean, contaminated or aggressive fluids not containing abrasivesubstances and solids. For use in spray irrigation systems, service watersystems, drainage, dewatering systems, fire-fighting systems, drawdown ofgroundwater levels, domestic water supply, air-conditioning systems, coolingcircuits, swimming pools, water supply systems.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000120

Etaprime BDNQ [m3/h]H [m]p [bar]T [°C]Hgeo [m]

25 - 100≤ 130

≤ 70≤ 10

≥ -30 - ≤ +90≤ 9

Description:Horizontal self-priming volute casing pump, single-stage, with open multi-vane impeller, close-coupled; pump shaft and motor shaft rigidly connected;ATEX-compliant version available.Applications:Pumping clean, contaminated or aggressive fluids not containing abrasivesubstances and solids. For use in spray irrigation systems, service watersystems, drainage, dewatering systems, fire-fighting systems, drawdown ofgroundwater levels, domestic water supply, air-conditioning systems, coolingcircuits, swimming pools, water supply systems.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000119

EZ B/LDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

25 - 50≤ 21

≤ 160≤ 16

≥ -5 - ≤ +80≤ 1500

Description:Self-priming multistage liquid ring pump in close-coupled (EZ B) or long-coupled (EZ L) design, with mechanical seal.Applications:Boiler feed applications, sanitary hot water, hydrophore systems for fresh orseawater and fresh water pre-heating.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000725

AUDNQ [m3/h]H [m]p [bar]T [°C]

40 - 200≤ 600

≤ 52≤ 10

≥ -10 - ≤ +80

Description:Horizontal, self-priming centrifugal pump, open or semi-open impeller,adjusted via wear plate, with mechanical seal, ATEX-compliant versionavailable.Applications:Pumping clean, contaminated and aggressive fluids also containing solids. Infresh water and seawater circuits, fire-fighting applications, as ballast andbilge pumps, and for drainage and waste water applications.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000750

AU MonoblocDNQ [m3/h]H [m]p [bar]T [°C]

40 - 50≤ 53≤ 37≤ 10

≥ -10 - ≤ +80

Description:Horizontal, self-priming centrifugal pump in close-coupled design, open orsemi-open impeller, adjusted via wear plate, with mechanical seal, driven byelectric motors or internal combustion engines, ATEX-compliant versionavailable.Applications:Pumping clean, contaminated and aggressive fluids also containing solids. Infresh water and seawater circuits, fire-fighting applications, as ballast andbilge pumps, and for drainage and waste water applications.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000715

  Pumps

  Pumps  

60

Submersible borehole pumps

UPAchrom 100 CNDNQ [m3/h]H [m]T [°C]

100≤ 22

≤ 300≤ +30

Description:Multistage centrifugal pump in shroud design made of stainless steel andplastic for well diameters of 100 mm (4 inches) and above, available withsingle-phase AC motor or three-phase motor with motor lead.Applications:Domestic water supply, irrigation and spray irrigation, drawdown ofgroundwater levels, in fire-fighting systems, cooling circuits, fountains,pressure booster systems and air-conditioning systems. UPAchrom 100 CN isalso suitable for drinking water applications to ACS.

Data for 50 Hz operation

Also available for 60 Hz

Control unit, Cervomatic, UPA Control http://shop.ksb.com/catalog/k0/en/product/ES000003

UPAchrom 100 CCDNQ [m3/h]H [m]T [°C]

100≤ 18

≤ 600≤ +30

Description:Multistage centrifugal pump in ring-section design made of stainless steel forwell diameters of 100 mm (4 inches) and above, available with single-phaseAC motor or three-phase motor with motor lead.Applications:Domestic water supply, irrigation and spray irrigation, drawdown ofgroundwater levels, in fire-fighting systems, cooling circuits, fountains,pressure booster systems and air-conditioning systems. UPAchrom 100 CC isalso suitable for drinking water applications to ACS.

Data for 50 Hz operation

Also available for 60 Hz

Control unit, Cervomatic, UPA Control http://shop.ksb.com/catalog/k0/en/product/ES000003

UPA 150CDNQ [m3/h]H [m]T [°C]

150≤ 79

≤ 440≤ +50

Description:All-stainless steel single-stage or multistage centrifugal pump in ring-sectiondesign for well diameters of 150 mm (6 inches) and above.Applications:Spray irrigation systems, irrigation systems, drawdown of groundwater levels,domestic water supply, fountains, heat pump systems, water supply systemsData for 50 Hz operation

Also available for 60 Hz

PumpDrive, KSB UMA-S http://shop.ksb.com/catalog/k0/en/product/ES000003

UPA 200, 200B, 250CDNQ [m3/h]H [m]T [°C]

200 - 250≤ 330≤ 460≤ +50

Description:Single-stage or multistage single-entry centrifugal pump in ring-sectiondesign for vertical or horizontal installation. Optionally available with liftcheck valve or connection branch.Applications:Pumping clean or slightly contaminated water in general water supply, sprayirrigation and irrigation, drawdown and maintenance of groundwater levels,fountains and pressure booster systems, mining, fire-fighting systems,emergency water supply, etc.

Data for 50 Hz operation

Also available for 60 Hz

PumpDrive, KSB UMA-S http://shop.ksb.com/catalog/k0/en/product/ES000003

UPA 300, 350DNQ [m3/h]H [m]T [°C]

300 - 350≤ 840≤ 480≤ +50

Description:Single-stage or multistage single-entry centrifugal pump in ring-sectiondesign for vertical or horizontal installation. Mixed flow hydraulic systemswith impellers that can be turned down. Optionally available with lift checkvalve or connection branch.Applications:Pumping clean or slightly contaminated water in general water supply, sprayirrigation and irrigation, drawdown and maintenance of groundwater levels,mining, fountains and fire-fighting systems, etc.

Data for 50 Hz operation

Also available for 60 Hz

PumpDrive, KSB UMA-S http://shop.ksb.com/catalog/k0/en/product/ES000003

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

61

UPA-Z / UPA-RDNQ [m3/h]H [m]T [°C]

> 350≤ 5000≤ 1500≤ +50

Description:Single-stage or multistage single-entry (UPA-R) or double-entry (UPA-Z)centrifugal pump in ring-section design for vertical or horizontal installation.Applications:Pumping clean or slightly contaminated water, seawater, liquefied gases andoils in water supply, offshore and cavern applications and in groundwatermanagement.

Data for 50 Hz operation

Also available for 60 Hz

Vertical turbine pumps

B PumpDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

80 - 500≤ 2600

≤ 160≤ 16

≥ -10 - ≤ +105≤ 3000

Description:Multistage vertical turbine pump with closed impellers, column section withbearing assembly, shaft sleeve, shaft sealed by gland packing, driven byelectric motor or diesel engine.Applications:Pumping clean water in agriculture, collection and irrigation, public watersupply, industry, fire-fighting systems

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000909

  Pumps

  Pumps  

62

High-pressure pumps

ComeoRpDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 - 1 1/425 - 32≤ 10,8≤ 79,5

≤ 10≥ -10 - ≤ +60

≤ 2900

Description:Multistage, horizontal, close-coupled centrifugal pumpApplications:Water supply, small pressure booster systems, irrigation, cooling

Data for 50 Hz operation

Also available for 60 Hz

Frequency inverter http://shop.ksb.com/catalog/k0/en/product/ES000912

Movitec H(S)IRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 1/4 - 2≤ 26,3≤ 195

≤ 25≥ -20 - ≤ +140

≤ 2900

Description:Multistage horizontal high-pressure centrifugal pumpApplications:Spray irrigation, general irrigation, washing, water treatment, fire-fightingand pressure booster systems, hot water and cooling water recirculation,boiler feed systems, etc.

Data for 50 Hz operation

Also available for 60 Hz

PumpMeter, PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000927

MovitecRpDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 - 225 - 125

≤ 160≤ 401

≤ 40≥ -20 - ≤ +140

≤ 2900

Description:Multistage vertical high-pressure centrifugal pump in ring-section design withsuction and discharge nozzles of identical nominal diameters arrangedopposite to each other (in-line design), close-coupled. With KSB SuPremE, amagnetless synchronous reluctance motor of efficiency class IE4/IE5 toIEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 orKSB PumpDrive 2 Eco variable speed system without rotor position sensors.Motor mounting points in accordance with EN 50347, envelope dimensions inaccordance with DIN V 42673 (07-2011). ATEX-compliant version available.Applications:Spray irrigation, irrigation, washing, water treatment, fire-fighting andpressure booster systems, hot water and cooling water recirculation, boilerfeed systems, etc.

Data for 50 Hz operation

Also available for 60 Hz

PumpMeter, PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000854

Movitec VCIRpDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

1 1/4 - 232 - 50≤ 22,5≤ 249

≤ 25≥ -10 - ≤ +120

≤ 2900

Description:Multistage vertical high-pressure immersion pump for installation on tanks orplatforms.Applications:Machine tools, industrial machine systems, condensate transport, paint shops.

Data for 50 Hz operation

Also available for 60 Hz

PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000870

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

63

MultitecDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

32 - 250≤ 1500≤ 1000

≤ 100≥ -10 - ≤ +200

≤ 3500

Description:Multistage horizontal or vertical centrifugal pump in ring-section design,long-coupled or close-coupled, with axial or radial suction nozzle, cast radialimpellers and motor-mounted variable speed system. ATEX-compliant versionavailable.Applications:Water supply, drinking water supply, industry, pressure boosting, irrigation,power stations, heating systems, filtering systems, fire-fighting systems,reverse osmosis systems, snow-making systems and washing plants.

PumpMeter, PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000214

Axially split pumps

OmegaDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

80 - 350≤ 2880

≤ 210≤ 25

≥ 0 - ≤ +140≤ 2900

Description:Single-stage axially split volute casing pump for horizontal or verticalinstallation, with double-entry radial impeller, mating flanges to DIN, EN orASME.Applications:Pumping water with a low solids content, e.g. in waterworks, irrigation anddrainage pumping stations, extraction duties in desalination systems, powerstations, fire-fighting systems, shipbuilding, district heating or cooling.Data for 50 Hz operation

Also available for 60 Hz

PumpMeter, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000071

RDLODNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

350 - 690≤ 10000

≤ 290≤ 30

≥ 0 - ≤ +140≤ 1450

Description:Single-stage axially split volute casing pump for horizontal or verticalinstallation, with double-entry radial impeller, mating flanges to DIN, EN orASME.Applications:Pumping water with a low solids content, e.g. in waterworks, irrigation anddrainage pumping stations, extraction duties in desalination systems, powerstations, fire-fighting systems, shipbuilding, district heating or cooling.Data for 50 Hz operation

Also available for 60 Hz

PumpMeter, Frequency inverter http://shop.ksb.com/catalog/k0/en/product/ES000170

RDLPDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

350 - 1200≤ 18000

≤ 550≤ 64

≥ 0 - ≤ +80≤ 1450

Description:Axially split volute casing pump for horizontal installation, with one, two orthree stages and double-entry radial impeller, mating flanges to DIN, ISO orANSI.Applications:Pumping water with a low solids content, e.g. in waterworks and long-distance water supply.

Data for 50 Hz operation

Also available for 60 Hz

Frequency inverter http://shop.ksb.com/catalog/k0/en/product/ES000171

  Pumps

  Pumps  

64

Hygienic pumps

VitachromDNQ [m3/h]H [m]p [bar]T [°C]

50 - 125≤ 340≤ 100

≤ 12≥ -30 - ≤ +110

Description:Service-friendly non-self-priming single-stage hygienic close-coupled pump inback pull-out design with magnetless KSB SuPremE motor of efficiency classIE4/IE5 and PumpDrive variable speed system. The pump features a semi-openimpeller and electropolished surfaces. It is very easy to clean by CIP/SIP thanksto its almost complete lack of dead volume or narrow clearances. Its wettedcomponents are made of 1.4404/1.4409 (AISI 316L/CF3M) stainless steel.Vitachrom is EHEDG-certified. All materials comply with FDA standards andEN 1935/2004. ATEX-compliant version available.Applications:Hygienic handling of fluids in the food, beverage and pharmaceuticalindustries as well as in the chemical industry.

Data for 50 Hz operation

Also available for 60 Hz

PumpMeter, PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000030

VitacastDNQ [m3/h]H [m]p [bar]T [°C]

32 - 200≤ 540≤ 105

≤ 10≥ -20 - ≤ +140

Description:Service-friendly volute casing pump with magnetless KSB SuPremE motor ofefficiency class IE4/IE5 and PumpDrive variable speed system. All wettedcomponents are made of 1.4404/1.4409 (AISI 316L/CF3M) stainless steel.Designed with very little dead volume; open impeller, electropolished surface,excellent efficiency. Hygienic design for the highest requirements oncleanability (CIP/SIP-compatible), certified by the TNO Nutrition and FoodResearch Institute to EHEDG standards. All materials comply with FDAstandards and EN 1935/2004. ATEX-compliant version available.Applications:Hygienic handling of fluids in the food, beverage and pharmaceuticalindustries as well as in the chemical industry.

Data for 50 Hz operation

Also available for 60 Hz

Other ratings possible on request

PumpMeter, PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000785

Vitacast BlocDNQ [m3/h]H [m]p [bar]T [°C]

25 - 150≤ 340≤ 105

≤ 10≥ -30 - ≤ +140

Description: Service-friendly volute casing pump with magnetless KSB SuPremE motor ofefficiency class IE4/IE5 and PumpDrive variable speed system. All wettedcomponents are made of 1.4404/1.4409 (AISI 316L/CF3M) stainless steel.Designed with very little dead volume; open impeller, electropolished surface,excellent efficiency. Hygienic design for the highest requirements oncleanability (CIP/SIP-compatible), certified by the TNO Nutrition and FoodResearch Institute to EHEDG standards. All materials comply with FDAstandards and EN 1935/2004. Trolley available among other accessories. ATEX-compliant version available.Applications:Hygienic handling of fluids in the food, beverage and pharmaceuticalindustries as well as in the chemical industry.

Data for 50 Hz operation

Also available for 60 Hz

Other ratings possible on request

PumpMeter, PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000785

VitaprimeDNQ [m3/h]H [m]p [bar]T [°C]

40 - 80≤ 58≤ 45≤ 10

≥ -20 - ≤ +100

Description:Service-friendly close-coupled side channel pump (self-priming) withmagnetless KSB SuPremE motor of efficiency class IE4/IE5 and PumpDrivevariable speed system. All wetted components are made of 1.4404/1.4409(AISI 316L/CF3M) stainless steel. Hygienic design for the highest requirementson cleanability (CIP/SIP-compatible). All materials comply with FDA standardsand EN 1935/2004. Trolley available among other accessories. ATEX-compliantversion available.Applications:Hygienic handling of fluids in the food, beverage and pharmaceuticalindustries as well as in the chemical industry.

Data for 50 Hz operation

Also available for 60 Hz

Other ratings possible on request

PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000787

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

65

VitastageQ [m3/h]H [m]p [bar]T [°C]

≤ 12,5≤ 150

≤ 16≥ -20 - ≤ +140

Description:Multistage centrifugal pump in close-coupled design for vertical or horizontalinstallation. All wetted components are made of 1.4401/1.4408 (AISI 316/CF8M) stainless steel. Versatile, robust and especially energy-efficient. CIP/SIP-compatible. All materials comply with FDA standards and EN 1935/2004.Trolley also available among other accessories.Applications:Processes with hygienic requirements in the food and beverage industries andin the chemical industry.

Data for 50 Hz operation

Also available for 60 Hz

Other ratings possible on request

http://shop.ksb.com/catalog/k0/en/product/ES000788

VitalobeDNQ [m3/h]H [m]p [bar]T [°C]Viscosity [cP]

25 - 200≤ 342≤ 200

≤ 20≥ -40 - ≤ +180

≤ 200000

Description: Sturdy rotary lobe pump in hygienic design, bi-directional operation possible,horizontal or vertical orientation of connections. Hygienic design, highly CIP/SIP-compatible due to its almost complete lack of dead volume or narrowclearances. All wetted components made of 1.4404/1.4409 (AISI 316L/CF3M)stainless steel; various rotor types, shaft seals and process connectionsavailable. Installed as a pump set with geared standardised motor. Vitalobe isEHEDG-certified. The pump elastomers comply with FDA standards andEN 1935/2004. Accessories include trolley, heatable casing or casing cover andoverpressure protection unit. ATEX-compliant version is available.Applications:Hygienic and gentle handling of sensitive or high-viscosity fluids in the food,beverage and pharmaceutical industries, the chemical industry and generalprocess engineering.

Data for 50 Hz operation

Also available for 60 Hz

Other ratings possible on request

PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000847

Pumps for power station conventional islands

CHTA / CHTC / CHTDDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

100 - 700≤ 5700≤ 5400

≤ 560≤ +270≤ 6750

Description:Horizontal high-pressure barrel-type pumps with radial impellers, single-entryand double-entry, multistage, with flanges or weld end nozzles to DIN andANSI.Applications:Pumping feed water and condensate in power stations and industrial plants,generation of pressurised water for bark peeling and descaling units.

Also available for 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000239

HGB / HGC / HGDDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

40 - 400≤ 2300≤ 5300

≤ 560≤ +210≤ 7000

Description:Horizontal radially split ring-section pump with radial impellers, single-entryor double-entry, multistage.Applications:Pumping feed water and condensate in power stations and industrial plants,pumping gas turbine fuels, generating pressurised water for bark peeling anddescaling units, snow guns, etc.

Also available for 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000233

  Pumps

  Pumps  

66

HGIDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

80 - 150≤ 430

≤ 2000≤ 215

≤ +180≤ 3600

Description:Horizontal radially split ring-section pump with radial impellers, single-entry,multistage.Applications:Pumping feed water and condensate in power stations and industrial plants.

Also available for 60 Hz

HGMDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

25 - 125≤ 350

≤ 1400≤ 140

≤ +160≤ 3600

Description:Horizontal radially split product-lubricated multistage ring-section pump withradial impellers, axial and radial single-entry inlet.Applications:Pumping feed water in power stations, boiler feed systems and condensatetransport in industrial plants.

Also available for 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000236

YNKDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

125 - 600≤ 5200

≤ 540≤ 100

≤ +250≤ 3300

Description:Horizontal radially split single-stage double-entry boiler feed booster pump(booster system) with cast steel single or double volute casing.Applications:Pumping feed water in power stations and industrial plants.

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000181

LUV / LUVADNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

100 - 550≤ 7000

≤ 300≤ 400

≤ +425≤ 3600

Description:Vertical spherical casing pump, radial impellers, single-entry, single- to three-stage. Suitable for very high inlet pressures and temperatures. Integrated wetwinding motor to VDE. Product-lubricated bearings, no need for oil supplysystems. Design to TRD, ASME or IBR.Applications:Hot water recirculation in forced-circulation, forced-flow and combined-circulation boilers for very high pressures and in solar power towers.Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000183

WKTBDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

150 - 300≤ 1500

≤ 370≤ 40

≤ +1401500

Description:Vertical can-type ring-section pump on base frame, multistage, first-stageimpeller designed as a double-entry suction impeller, radial impellers. Flangesto DIN or ANSI.Applications:Pumping condensate in power stations and industrial plants.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000506

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

67

SEZ / SEZT / PHZ / PNZQ [m3/h]H [m]T [°C]n [rpm]

≤ 80000≤ 120≤ +40≤ 980

Description:Vertical tubular casing pump with open mixed flow impeller (SEZ), mixed flowpropeller (PHZ) or axial propeller (PNZ), pump inlet with bellmouth or suctionelbow, pull-out design available, discharge nozzle arranged above or belowfloor level, flanges to DIN or ANSI standards available.Applications:Pumping raw, clean, service and cooling water in industry, water supplysystems, power stations and seawater desalination plants.

Data for 50 Hz operation

Also available for 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000173

SNW / PNWDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

350 - 800≤ 9000

≤ 60≤ 10

≤ +60≤ 1500

Description:Vertical tubular casing pump with mixed flow impeller (SNW) or axialpropeller (PNW), single-stage, with maintenance-free Residur bearings,discharge nozzle arranged above or below floor level.Applications:Irrigation and drainage systems, stormwater pumping stations, pumping rawand clean water, water supply, cooling water.

Data for 50 Hz operation

Also available for 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000176

BeveronQ [m3/s]H [m]

≤ 30≤ 27

Description:Concrete volute casing pump with mixed flow impeller, single-stage, withzero-maintenance Residur bearings lubricated by the fluid handled.Applications:Coast protection and flood control, irrigation and drainage, low-lift pumpingstations, reservoir filling, cooling water, raw and clean water.

Data for 50 Hz operation

Also available for 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000868

SPYDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

350 - 1200≤ 21600

≤ 50≤ 10

≤ +105≤ 1480

Description:Long-coupled volute casing pump, single-stage, in back pull-out design.Applications:Irrigation, drainage and water supply systems, for pumping condensate,cooling water, service water, etc.

Data for 50 Hz operation

Also available for 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000422

Pumps for nuclear power stations

RERDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

≤ 800≤ 40000

≤ 140≤ 175

≤ +350≤ 1800

Description:Vertical, single-stage reactor coolant pump with forged circular casing platedon the inside, with diffuser, either with integrated pump thrust bearing orshaft supported by motor bearing.Applications:Reactor coolant recirculation in nuclear power stations.

Available for 50 Hz and 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000144

  Pumps

  Pumps  

68

RSRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

≤ 750≤ 24000

≤ 215≤ 175

≤ +350≤ 1800

Description:Vertical single-stage reactor coolant pump with cast or forged casing, shaftsupported by motor bearing.Applications:Reactor coolant recirculation in nuclear power stations.

Available for 50 Hz and 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000146

RUVDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

≤ 650≤ 22000

≤ 111≤ 155

≤ +350≤ 1800

Description:Vertical, single-stage reactor coolant pump. Seal-less design with integratedwet rotor motor and integrated flywheel. Product-lubricated bearings, no oilsupply systems required.Applications:Reactor coolant recirculation in generation III+ nuclear power stations.

Available for 50 Hz and 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000848

PSRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

≤ 600≤ 9000

≤ 45≤ 75

≤ +300≤ 2000

Description:Vertical pump set integrated in the reactor containment floor, seal-less pumpwith leak-free, low-maintenance wet rotor motor.Applications:Reactor coolant recirculation in boiling water reactors.

Available for 50 Hz and 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000150

RHDDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

125 - 500≤ 6500≤ 1000

≤ 150≤ +210≤ 6500

Description:Horizontal single-stage double-entry main feed water pump MFWP, cast orforged variant.Applications:Main feed water supply (MFWS) in steam generation systems of nuclearpower stations.

Available for 50 Hz and 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000138

LUV NuclearDNQ [m3/h]H [m]p [bar]T [°C]

40 - 600≤ 7000

≤ 300≤ 320

≤ +430

Description:Vertical pump with integrated motor, single-entry, single- to three-stage.Suitable for very high inlet pressures and temperatures. Integrated wetwinding motor to VDE. Product-lubricated bearings, no oil supply systemsrequired. Design to ASME Section 3, KTA, etc.Applications:As reactor water clean-up pump in boiling water reactors, reactor coolantpump in boiling water and pressurised water reactors and recirculation pumpin test facilities.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000855

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

69

RHMDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

≤ 150≤ 300

≤ 2100≤ 220

≤ +180≤ 8000

Description:Horizontal multistage barrel pull-out pump.Applications:Core flooding, emergency cooling and residual heat removal systems,chemical and volume control systems, control rod drive systems, high-pressureand medium-pressure safety injection systems, emergency feed water systems,start-up and shut-down feed water systems, high-pressure charging.

Available for 50 Hz and 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000245

RVMDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

≤ 85≤ 50

≤ 2000≤ 200

≤ +100≤ 6000

Description:Vertical multistage barrel pull-out pump.Applications:Core flooding, emergency cooling and residual heat removal systems,chemical and volume control systems, high-pressure and medium-pressuresafety injection systems.

Available for 50 Hz and 60 Hz

Higher ratings possible upon request

http://shop.ksb.com/catalog/k0/en/product/ES000243

RHRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

≤ 500≤ 6000

≤ 190≤ 63

≤ +200≤ 3600

Description:Horizontal annular casing pump with forged or cast pressure boundary anddiffuser.Applications:Core flooding, emergency cooling and residual heat removal systems, ancillarysystems, acid feed system and low-pressure injection system, componentcooling water systems.

Available for 50 Hz and 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000140

RVRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

≤ 500≤ 6000

≤ 190≤ 63

≤ +200≤ 3600

Description:Vertical annular casing pump with forged or cast pressure boundary anddiffuser.Applications:Core flooding, emergency cooling and residual heat removal systems, ancillarysystems, acid feed system and low-pressure injection system, componentcooling water systems.

Available for 50 Hz and 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000142

Pumps for desalination by reverse osmosis

RPH-RODNQ [m3/h]H [m]p [bar]T [°C]

100 - 350≤ 2500

≤ 110≤ 80

≤ +40

Description:Horizontal radially split volute casing pump for dry installation, made ofsuper-duplex stainless steel.Applications:Booster pump for RO seawater desalination systems.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000570

  Pumps

  Pumps  

70

HGM-RODNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

65 - 250≤ 1500

≤ 950≤ 120

≥ 0 - ≤ +40≤ 3600

Description:Horizontal radially split product-lubricated multistage ring-section pump withradial impellers and plain bearings, axial and radial single-entry inlet. Duplexstainless steel variant or super duplex stainless steel variant, also suitable forchilled water applications.Applications:High-pressure pump for RO seawater desalination systems

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000237

Multitec-RODNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

50 - 150≤ 850

≤ 1000≤ 100

≥ -10 - ≤ +45≤ 3500

Description:Horizontal, multistage centrifugal pump in ring-section design. Axial suctionnozzle. Discharge nozzle can be turned in steps of 90°. Closed radial impellers.Made of duplex or super-duplex stainless steel.Applications:High-pressure pump for RO seawater desalination systems and geothermalsystems (re-injection of geothermal water into the aquifer).

Data for 50 Hz operation

Also available for 60 Hz

PumpDrive, KSB SuPremE http://shop.ksb.com/catalog/k0/en/product/ES000508

Positive displacement pumps

RC / RCVDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

20 - 100≤ 78

≤ 100≤ 10

≥ +5 - ≤ +80≤ 1500

Description:Helical gear pump, self-priming, with bypass valve, close-coupled design, forhorizontal installation with baseplate or vertical installation. With mechanicalseal.Applications:Fuel feed, handling fuel, lubricating oil and viscous fluids, lubrication systems.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000744

Fire-fighting systems

EDSDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

32 - 300≤ 840≤ 140

≤ 16≥ +5 - ≤ +50

≤ 3000

Description:Automatic fire-fighting system consisting of a jockey pump and one or severalduty pumps, with electric motor or diesel engine. Includes manifold, valves,accessories and control unit. To EN 12845, CEA 4001, UNE-23500, NFPA-20, etc.Applications:Office buildings, hotels, industry, shopping malls, etc.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000726

Not available for worldwide sale   Factory-automated   Automation available

  Pumps

  Pumps  

71

DU / EUDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]

32 - 350≤ 2500

≤ 150≤ 25

≥ +5 - ≤ +50≤ 3000

Description:Automatic fire-fighting system consisting of pumps with electric motor ordiesel engine and control unit. To EN 12845, CEA 4001, UNE-23500, NFPA-20,FM, etc.Applications:Office buildings, hotels, industry, shopping malls, etc.

Data for 50 Hz operation

Also available for 60 Hz

http://shop.ksb.com/catalog/k0/en/product/ES000727

  Automation

  Automation  

72

Control units

Controlmatic ENo. of pumpsU [V]

≤ 11~230

Description:Automatic control unit for pressure-controlled starting, flow-controlledstopping and monitoring of a single pumpApplications:In water supply systems in combination with Multi Eco, Ixo, UPA 100C.

http://shop.ksb.com/catalog/k0/en/product/ES000276

Controlmatic E.2No. of pumpsU [V]

≤ 11~230

Description:Automatic control unit for pressure-controlled starting, flow-controlledstopping and monitoring of a single pumpApplications:In water supply systems in combination with Multi Eco, Ixo, UPA 100C.

http://shop.ksb.com/catalog/k0/en/product/ES000276

Cervomatic EDP.2No. of pumpsU [V]

≤ 11~230 / 3~400

Description:Automatic control unit for pressure-controlled starting and either pressure-controlled or flow-controlled stopping and monitoring of a single pump.Applications:Use in water supply systems with pumps of the Multi Eco, Ixo, UPA 100C andUPA 150C type series with single-phase or three-phase motors.

http://shop.ksb.com/catalog/k0/en/product/ES000275

LevelControl Basic 2No. of pumpsP [kW]U [V]

≤ 2≤ 22

1~230 / 3~400

Description:Level control unit for controlling and protecting either one or two pumps.DOL starting up to 4 kW, star-delta starting up to 22 kW. Higher ratings onrequest.Applications:Tank drainage using float switches, digital switches, 4...20 mA, pneumatic (w/o compressor) or bubbler system in building services and waste waterapplications. Tank filling using float switches, digital switches or 4...20 mA inbuilding services and water supply applications.

Higher ratings and other mains voltages available

on request

http://shop.ksb.com/catalog/k0/en/product/ES000603

UPA ControlNo. of pumpsP [kW]U [V]

≤ 13

1~230 / 3~400

Description:The KSB switchgear is suitable for level control and protection of submersibleborehole pumps, submersible motor pumps and dry-installed pumps withsingle-phase AC motors 1~ 230 V or three-phase motors 3~ 230 / 400 V / 50 Hz.The motor is started DOL. Enclosure: IP56, dimensions: 205 × 255 × 170 mm(H × W × D).Applications:Irrigation and filling or draining tanks in water supply applications incombination with 4" and 6" pumps.

http://shop.ksb.com/catalog/k0/en/product/ES000006

Not available for worldwide sale

  Automation

  Automation  

73

Hyatronic NNo. of pumpsP [kW]U [V]

≤ 622

3~400

Description:Pump control system in control cabinet for cascade starting and stopping ofup to 6 pumps on the mains.Applications:For draining tanks and sumps in drainage and waste water disposalapplications. For filling tanks in water supply applications. Level measurementusing float switch or 4...20 mA sensor.

Higher ratings and other mains voltages available

on request

http://shop.ksb.com/catalog/k0/en/product/ES000303

Monitoring and diagnosis

AmacontrolNo. of pumpsPumpU [V AC]

≤ 1Amacan

230

Description:Monitoring system for submersible motor pumps, with tripping function.

Legal information/Copyright

Product Portfolio Pumps ı Automation

All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,edited or processed for any other purpose, nor otherwise transmitted, published or made available to athird party without the manufacturer's express written consent.

Subject to technical modification without prior notice.

© KSB SE & Co. KGaA, Frankenthal 06/12/2018

The KSB Newsletter –

don’t miss out, sign up now:

www.ksb.com/newsletter

KSB SE & Co. KGaAJohann-Klein-Straße 9 • 67227 Frankenthal (Germany)Tel. +49 6233 86-0www.ksb.com 05

06.0

2/26

-EN

/ 01

/01/

2019

/ ©

KSB

SE

& C

o. K

GaA

201

9 ∙ S

ub

ject

to

tec

hn

ical

mo

dif

icat

ion

wit

ho

ut

pri

or

no

tice

.

Technology that makes its mark

You can also visit us atwww.ksb.com/socialmedia


Recommended