PWROG Global Expertise • One Voice

01Vners

UP Plan Discusio

R Pubi Meein

Apri 1621

Page 2: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

AGENDA

4444" Introduction" UPI Plant Alignments• ECCS Operation for UPI Plants• Hot Leg Breaks* Cold Leg Breakse UPI Plant Considerations• Additional Considerations

PRESSURIZEDftmo--

WATER REACTOR OWNERS G R 0 U P

Page 3: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

Introduction

• The following discussion describes how thecurrent program applies to UPI plants.

6.PRESSURIZED WATER REACTOR OWNERS GROUP

Page 4: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

UPI PLANT ECCS ALIGNMENTV

* Initially, ECCS is aligned to take suction from theRefueling Water Storage Tank (RWST).

* ECCS flow is directed to both cold legs, and intoreactor vessel upper plenum via UPI lines.

- High Head Safety Injection (HHSI) pumps providecoolant to cold legs at about 500 gpm.

- Residual Heat Removal (RHR) pumps providecoolant to reactor vessel upper plenum via the UPIlines at about 1000 gpm per minute per UPI line.

6 ,PRESSURIZED WATER REACTOR OWNERS GRC )UP

Page 5: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

UPI PLANT ECCS ALIGNMENT

RWST injection alignment maintained untilRWST low level is reached:

- ECCS is then realigned to take suction from andrecirculate coolant from the sump.

- The HHSI pumps are secured (no flow is provided tothe cold legs).

- All ECCS flow is provided to the reactor vessel via theRHR pumps via the UPI lines.

- For some plants CL injection is re-established at a

later time.

PRESSURIZED WATER REACTOR OWNERS GRO UP

Page 6: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

ECCS Operations for UPI Plants"q,

V.

Sup reiclto

UPI + CL from RWST

Only UPI from sump on

recirculation

UPI + CL from sump @

5 hr. 30 min after

transfer to sump

recirculation

No spray credited for

LBLOCA

UPI + CL from RWST

Only UPI from sump on

recirculation

UPI + CL from sump @ 4

hr. 30 min after transfer

to sump recirculation

Use of spray from sump

after recirculation

initiation for dose

consideration (confirm

details with licensee)

UPI + CL from RWST

Only UPI from sump on

recirculation

Does not initiate CL

recirculation

No spray credited for

LBLOCA

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 7: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

Cold Leg Breaks"41 0 1

During RWST Injection:Coolant to the core providedby both:- Intact cold leg (by filling the

lower plenum anddowncomer, and,

- Flooding the core from thebottom) and from the upperplenum as the UPI flow fallsfrom the upper plenum intothe core.

Large Cold Leg Break LOCA(injection from IRWST Phase -RHR discharge to the upperplenum and HHSI to cold legs)

Spill

- Uppe Cw PLAta- Top Or FPII

- DUM OEMM-LOWf COM PIM

-LOWE eSiPgxit PL1h

* Excess coolant to the reactorvessel spills out the cold-legbreak.

PRESSURIZED WATER REACTOR OWNERS GROUP111110 .

Page 8: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

Cold Leg Breaks

ECCS realigned to Sump* No ECCS coolant provided to

cold legs.* Coolant supplied to core by

only UPI lines.* Direction of flow is from;

- Upper plenum into the core.- Downward through the core.

Large Cold Leg Break LOCA(recirculation from Sump

Phase - RHR discharge to theupper plenum and HHSl to

cold legs terminated)

CajýI tVper Piumi

q~ffPMVU HO L

N"pMlCOiL94

"'i-f -0

- Upward through thedowncomer.

- Then out the break.Similar to a hot leg break fornon-UPI plants.

La1mw CMlvno

PRESSURIZEDMft.-

WATER REACTOR OWNERS GROUP

Page 9: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

Hot Leg Breaks

During RWST Injection" Coolant to the core provided by

both:- Intact cold leg (filling the lower

plenum and downcomer, and,the flooding the core from the c,,L

bottom).

- Flooding from the upperplenum as the UPI flow fallsfrom the upper plenum into thecore.

" Excess coolant supplied to thecore spills out the hot-legbreak.

,qqP

Large Hot Leg Break LOCA(injection from IRWST Phase -

RHR discharge to the upperplenum and HHSl to cold legs)

Waw: apin

-uppo 0M. p1311

Le~r szppmt P&

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 10: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

Hot Leg Breaks

ECCS realigned to sump* No ECCS coolant is provided to the cold

legs." Coolant is supplied to the Reactor

Vessel Upper Plenum via the UPI lines.- Flow mixes with coolant in upper plenum. c,,g

- Cooler fluid flows downward in low powerassemblies at periphery of the core.

- Flow is upwards into the Upper Plenumin high power assemblies as coolantheats and boils.

- Excess coolant spills out hot-leg break.

• Water level in downcomer maintainedconsistent with core level.

• Similar to a cold leg break for non-UPIL plants.

Large Hot Leg Break LOCA(Recirculation from Sump Phase -

RHR discharge to the upper plenumand HHSI to cold legs Terminated)

-uppff~ccpmat

LOWn Caw PUM

Lmv ippafl Pa*

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 11: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

Hot Leg Breaks

ECCS flow to cold legsreestablished

" For Plant A, ECCS flow to the coldlegs is reestablished at 51/2 hours.

* For Plant B, flow to the cold legs isreestablished at 4½/ hours.

" Flow patterns are similar toestablishing Hot Leg Switch-Over(HLSO) flow to the hot legs of non-UPI plants.

6 ,PRESSURIZED WATER

Large Hot Leg Break LOCA(Recirculation from Sump Phase- RHR discharge to the upperplenum and HHSl to cold legs)

slM

LONW Cone PD

L-er MW S*pftL

REACTOR OWNERS GROUP

Page 12: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

UPI Plant Considerationsp pg

* During sump recirculation;

- Boiling in the core is vigorous.

- Steam is escaping.

- Flow into core is down near periphery.

- Continual jet-like UPI flow impinges on upperinternals, directs flow in multiple directions, includinginto the core.

- Promotes turbulence and mixing of coolant in theupper plenum.

L PRESSURIZED WATER REACTOR OWNERS GROUP

Page 13: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

Additional Considerationsqq

* Fibrous debris entering upper plenum via UPI isavailable to the core.

- Steaming rate and core flow patterns influence:

" Where and how much debris enters the core.

" If and where it accumulates in the core.

- Thermal-hydraulic analyses show, in general, flow inthe core is:

" Up through hot fuel assemblies.

" Down in core peripheral and lower power assemblies.

SLimits will be established as part of this program.

6 PRESSURIZED WATER REACTOR OWNERS GRO UP

Page 14: PWR Owners Group GSI-191 Closure Activities: UPI Plant ...

qq

Questions?

PRESSURIZED WATER REACTOR OWNERS GROUP