PWROG Global Expertise One Voice I Q Owners C;
Transcript
Page 1: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

PWROG Global Expertise • One VoiceI Q

Owners C;

Page 2: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Agenda

* Subscale Test Facility Parametric Tests" Full-Area FA Testing* Summary of Results - Final Limits

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 3: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale Test Facility Parametric

PRESSURIZED WATER REACTOR OM

Tests

[NERS GROUP

Page 4: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale Loop Testing

Purpose: Provide test data that supports the development of higher fibrous debrisloading acceptance criteria

o Examine effects of parametric variationo Addresses limits and conditions in the NRC SE (WCAP-16793-NP-A Rev 2)o Addresses ACRS concerns

Experimental Objective: Determine the relative importance of the following variableson debris bed head loss:o Flow Rateo Debris Concentrationo Water Chemistry (pH and buffer type)o Particulate Size and Distribution

o Capture Geometryo Grid (fuel rod diameter and subchannel pitch)

o Core Inlet

o Fiber Size and Distributiono Particulate-to-Fiber Ratio (p:f)

RESSURIZED WATER REACTOR OWNERS GROUP

Page 5: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Parametric Tests - Round 1

o 23 Test Series Completed* 95 Independent Tests

* Broken into 2 Phases

o Phase 1 Testing* Shakedown Facility* Determine baseline condition for parametric studies

* Flow rate variation study

* 9 Test Series / 36 Independent Tests

o Phase 2 TestingP Parametric Studies

* 14 Test Series / 59 Independent Tests

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 6: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Parametric Test Matrix

Flow Fiber Debris

Test Series Rate Loading Injection p:fBuffer Particulate Grid TypeTime Type Size(gpm) (g) (m(min)

2 2.67 25 30 10:1 7 NaOH A RFA

11 11.5 25 30 10:1 7 NaOH A RFA

13 8.2 25 300 10:1 7 NaOH A RFA

9 8.2 25 30 0:1 7 NaOH A RFA

3 8.2 25 30 1:1 7 NaOH A RFA

14 8.2 25 30 15:1 7 NaOH A RFA

11 8.2 12.5 30 10:1 7 NaOH A RFA

14 8.2 12.5 30 30:1 7 NaOH A RFA

19 8.2 25 30 10:1 9 NaOH A RFA

20 8.2 25 30 10:1 7 TSP A RFA

21 8.2 25 30 10:1 7 NaTB A RFA

16 8.2 25 30 10:1 7 NaOH B RFA

17 8.2 25 30 10:1 7 NaOH C RFA

18 8.2 25 30 10:1 7 NaOH D RFA

12 8.2 25 30 10:1 7 NaOH A HMP22 8.2 25 30 10:1 7 NaOH A UFA

23 8.2 25 30 10:1 7 NaOH A OFA

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 7: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale Parametric TestConclusions

" Most important contributors include flow rate, p:f ratio andparticulate size

- Higher flow rates more limiting (as expected)

- Higher p:f ratios more limiting (as expected w/o chem effect)

- For the conditions tested, increasing particulate size results in ahigher pressure drop across the debris bed

° Inputs having a small impact include:- pH

- Grid geometry

- Buffer

Inputs not found to be significant include:- Debris Concentration / Injection Rate

P RESSURIZED WATER REACTOR OWNERS GROUP

Page 8: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

U

Subscale Test Results - Round 2

Round 2 Testing Began 06/02/2014- Focus on Particulate Size and p:f Ratio

- ObjectivesDetermine an appropriate particulate size distribution for final debrislimit tests.

* Determine the influence of p:f ratio and usea strategy for addressing particulate load in

- 43 additional tests• Silicon Carbide used as Particulate Surrogate" Particulate Sizes up to 72 pIm Tested• W-RFA Grid

that information to formulatethe final limits.

PRESSURIZED WATER REACTOR OWNERS G R 0 U P

Page 9: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale ParticulateDistribution Results

Size and

Comparison of Pressure Drop across Debris Bed16

1-Particulate Size A14 - Particulate Size B f C Type A: 10[im mean diameter

-2Particulate Size C T12 - Particulate Size D Type B: 6 lim mean diameter0 105 Type C: 17 Iam mean diameter

6 -Type D: uniform mix of A,B and4

2 -

00 5 10 15 20 25

Cumulative Fiber Load (g)

The pressure drop is shown to be sensitive to the particulate size.

- Larger particles tend to capture in the debris bed more readily.

6 PRESSURIZED WATER REACTOR OWNERS GROUP

Page 10: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale ParticulateDistribution Results

Size and

* Filter Bag results can be used to determine the capture efficiency ofparticulates as a function of mean diameter.

" Results show that the capture efficiency increases with increasingparticulate size.

* The hypothesis is that larger particulate tend to capture in the bed moreefficiently. This reduces the bed porosity resulting in higher pressuredrops.

" At these particulate sizes, packing factor appears to be less important

I

Man Patclt Avrg patclt atclt atr e r ssueDo

10.4 233.90 6.4 1.5

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 11: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale Particulate Size andDistribution Results

Estimates from packing of non-spherical particles (i.e. fiber strands)indicate that near 100% filtration efficiency will occur at a particulatesize of >55 rtm* Above 100% filtration efficiency, the dP will stabilize or begin to decrease* This defines the maximum particulate size that should be tested• Subscale testing was done to confirm

Since it is not expected that any single size of particulate willexclusively arrive at the fuel inlet, some distribution of particulatesize needs to be defined" Previous work for GSI-191 has suggested that a uniform distribution be

considered* Filter bag results from subscale testing and plant strainer test data suggest that

the distribution is weighted toward smaller particulates

:PRESSURIZED WATER REACTOR OWNERS GROUP

Page 12: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale Particulate Size andDistribution Results

Particulate Size Distribution Past Sump Strainer40 -

35 -

30

.25

~20O

9L 15

10 "

55

00-10 10-20 20-30 30-40 40+

Diameter, micron

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 13: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

I

Subscale Testing - Particulate Size

* Prototypically, a broad range of particulate sizes areexpected to penetrate the sump strainer.

- Strainer test data supports this assertion.

- Test Strategy* Determine the particulate size that results in the highest

dP." Define a particulate size distribution that ends at the

limiting particulate size- Follows a distribution consistent with available strainer

penetration data.

6,,R.._ESSURIZED WATER REACTOR OWNERS GROUP

Page 14: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Particulate Size Test ResultsFiber: 56 g/FA, p:f Ratio: 10:1, 36.7 gpm/FA

35

30

CL25

a.o020

@15

010

5

0

__-I

-. _ __ __ _ __ __ _ __ _ __ __

U

01

01

I.

3

90

80

70

6050

40

30

20

10

0

0 10 0 1020 30 40 50 60

Mean Particulate Size (pm)

70 80 20 30 40 50 60

Mean Particulate Size (prm)

70 80

* 24 pm particulate create highest dP

* Particulates larger than 50 pm captured at > 80% efficiency

, PRIESSURIZED WATER REACTOR OWNERS GROUP

Page 15: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Determination of Size Distribution

40

35

gF30

425

20

15

a. 10

5

0

0 10 20 30 40 50

Particulate Diameter (lun)

PRESSURIZED WATER REACT 0OR OWNERS GROUP

Page 16: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

p:f Ratio Study with Particulate SizeDistribution

p:f ratio testing was done using the newly defined particulate sizedistribution.

* Results indicate that the bed behaves very differently depending on p:f ratio.* Three "Regimes" Identified

- Regime I - Stable Fiber Dominated Debris Bed- Regime II - Stable Particulate Dominated Debris Bed- Regime III - Unstable Particulate Dominated Debris Bed

aElI.-

&

p*I IRt

' I I

I I

pf ati

45

40

35

•. 30

o 25

20• 20

15

10

5

0

b0 8-9-

0 10 20 30 40

Total Injected p:f Ratio

50 60

P R EMom-

SSURIZED WATER REACTOR OWNERS GROUP

Page 17: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale Conclusions

* Additional Testing- Prototypical Core Inlet Geometry

- AFP hole size/geometry testing

- Final Limits

6 hPRESSURIZED WATER REACTOR OWNERS GROUP

Page 18: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Full-Area FA Testing

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 19: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Full-Area FA Testing" Original intent of PA-SEE-1 090 was to test in two stages:

- Subscale Facility to do parametric studies and define small set ofconditions that provided limiting pressure drop

- Full-Area Facility to do final limits testing using the inputs fromthe Subscale Facility

" After 139 tests performed in the Subscale Facility, areview of the results indicates that full-area FA testing isnot necessary

° Basis for decision:Fidelity/repeatability of subscale testsThe scaling of the Subscale Facility adequately represents a full-area fuel assembly with acceptable distortion

rending of subscale results agrees with pressure drops fromfull-area FA testing done for WCAP-1 6793-NP, Rev. 2

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 20: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Head Loss Scaling

As part of the subscale facility design process, a scaling analysiswas performed to:

- Determine subscale facility dimensions and test conditions such that thedominant physical processes are preserved.

- Define necessary scaling ratios such that the subscale results can betranslated to the prototypic system and the analytical model.

* A bottom-up, dimensional scaling analysis is performed thatfocuses on debris bed formation and the resulting pressure dropacross the bed.

Four dimensionless scaling groups are defined and priority is placed on theinertial loss term associated with flow through a packed bed.

- Debris material similitude is assumed.

- The impact of fluid temperature, flow rate, and channel geometry areconsidered.

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 21: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Head Loss Scaling

• A summary of the dimensionless groups is shown below:

Scaling Group Definition Ratio (Subscale:FA) Distortion (%)

Re*= pf 9 pdpU viscous forces 11'If (1 - -) inertial_forces

Ga* 7 g9 3 d 3 3 viscousforcesG*= Pf9PP1:1 0

f2 (1- _)3 bouyancy_ forces

Re pf dhU viscous_ forces 0.917:1 -8.3I-If inertial_ forces

St = p fluid_ response time 1.091:1 9.1dh / U particle_ response- time

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 22: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale FacilityGeometric Scale

Assembly to Assembly Gap- Gaps formed between adjacent assemblies installed in a

PWR core result in long narrow gaps, that areapproximately 0.04 in wide, and gap intersections thatmay affect debris bed morphology and the resulting headloss.

- Previous testing simulated this gap with the FA centeredin the test vessel with a 1/2 gap around the periphery

" Wall boundary condition instead of a symmetry condition whichwas an unevaluated distortion

" The capture geometry near the edge did not provide a ledgefor debris capture

- Based on these observations, the Subscale Facility usesa prototypic gap which is centered in the test vessel.

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 23: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale FacilityGeometric Scale

Assembly to Assembly Gap- Need to maintain the gap with and an appropriate

flow area to gap ratio- For a W 17x17 FA, the ratio of gap area to FA pitch is

[(8.466)2-(8.466-0.04)2]/(8.466)2, or 0.94% of the totalFA area occupied by the gap

- In the subscale facility, the ratio of the gap area to thetest section footprint is 1- (42- 0.04*4)/42, or 1% ofthe subscale facility flow area -prototypicassembly-to-assembly

MMMCýMMMMMMMMMMMNEEMBERMMMMMMMMMMMMMMMMM

sealed outer grid strap

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 24: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale FacilityGeometric Scale

Thimble and Instrument Tubes- Fuel assemblies consist of an array of fuel rods,

instrument tubes, and thimble tubes all with variousdiameters.

- The subscale rod bundle consists of two 4x8 grid sectionswith a gap separating the sections. Each grid sectioncontains a combination of thimble tubes, instrumentationtubes and fuel rods.

- The ratio of these components to a full-area fuel assemblyis compared to ensure that the Subscale Facilityadequately represents a full-area fuel assembly.

" For a W 17x1 7, the ratio of thimble and instrument tubes to fuelrods is 0.095

" In the Subscale Facility, the ratio of thimble tubes to fuel rods is0.103

SPRESSURIZED WATER REACTOR OWNERS GROUP

Page 25: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale FacilityGeometric Scale

Thimble and Instrument Tubes- To evaluate this impact on debris bed head loss,

the appropriate dimensionless parameter is thepercent open flow area.

" Considering only the rods themselves and neglectingthe gap formed between assemblies, the percent openarea for a 17x1 7 RFA assembly is 52.7%

" For the Subscale Facility, the percent open area is52.6%

- Therefore, the effect of this potential distortion isnegligible

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 26: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale FacilityGeometric Scale

Hydraulic Diameter- PWR's have open lattice cores and there is no wall

between assemblies.- However, in a full-area fuel assembly test there would

be a wall around the periphery of the assembly.- Therefore, the Subscale Facility hydraulic diameter is

assessed against a fuel assembly that is surroundedby a flow column.

- The full-area FA hydraulic diameter is 0.399 inThe Subscale Facility hydraulic diameter is 0.366 inThe hydraulic diameter ratio is then 0.917

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 27: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Subscale FacilityGeometric Scale

Fiber and Particulate Mass- Debris limits are currently reported on a single FA

basis

- As described above, the edge effects, gap betweenFAs, and grid geometry are appropriately representedin the Subscale Facility

- Therefore, the debris load in the Subscale Facility aredirectly relatable to a full-area FA using the flow arearatio, which is 0.233

- For example, 3.5 g of fiber in the Subscale Facilitywould equate to 15 g of fiber in a single FA

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 28: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Scaling -Conclusions

The scaling analysis completed above demonstrates that theSubscale Facility is comparable to a full-area fuel assembly interms of distortions related to pressure drop across a debrisbed.

* It has been shown that- the geometric scale of the Subscale Facility has negligible

distortion when compared to a full-area fuel assembly.- the dominant physical phenomena expected to drive debris bed

head loss are reasonably preserved.* Therefore,

Using the flow area ratio between the subscale and a full-areafuel assembly it is possible to relate the subscale debris loadingto that of a full-area fuel assembly.

- It is also possible to relate the subscale flow condition to that ofthe full-area fuel assembly using the same flow area ratio.

P RESSURIZED WATER REACTOR OWNERS GRC UP

Page 29: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Confirmation of dP Trends° Numerous tests have been performed in the subscale test facility

" Variations in input include

- Fibrous and particulate debris mass

- Initial particulate-to-fiber (p:f) ratio

- Flow rate (velocity)

- Particulate size° Results include

- Pressure drop (dP) across debris bed

- Amount of fiber and particulate in debris bed

• To better understand the debris bed morphology and behavior of thebed under a variety of conditions, a semi-empirical model wasdeveloped to represent subscale data

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 30: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Description of Model

* The pressure drop model for flow through the debris bed takes thegeneral form defined for flow through compressible porous media:

AP 2- A U + BU2 (Eq. 1)L

* WhereAU = viscous energy loss termBU2 = inertial energy loss termU = superficial velocityAP = hydraulic pressure across a layer of porous media of length

LA, B = constants dependent on the fluid properties of the flow and

the media composition

RESSURIZED WATER REACTOR OWNERS GROUP

Page 31: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Description of Model

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 32: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Description of Model

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 33: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Description of Model

PRESSURIZED WATERNOM.-

REACTOR OWNERS GROUP

Page 34: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Comparison of Model Predictions toExperimental Data

45 4

- 40-o$A-. 35

C.30

•01 5

10

u2

3.5

0.0.

2.5

1n 2a.

1.5

,- 1

u

0.55

0 00 5 10 15 20 25 30 35 40 45 0 0.5 1 1.5 2 2.5 3 3.5 4

Measured Pressure Drop (psid) Measured Pressure Drop (psid)

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 35: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Prediction of FA HeadLoss

° The model described above is used to predict variousresults from the WCAP-16793-NP, Rev. 2 test program

" Tests from both the W and CDI test facility were selected- Covered a range of flow rates and conditions- Developed a single debris bed

An over-prediction of the pressureindication that the results from theconservative relative to a full-area

drop provides a clearSubscale Facility areFA test.

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 36: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

WCAP-16793-NP, Rev.2 Tests Selected

mmutiuimiumbrLod semlTs

Note 1: Two debris beds were formed during this test. One bed formed at the P-grid/bottom nozzle and the second bed formed at the firstmechanical grid. The total debris load from the tests was approximated to be an even split between the two bed locations and the assemblypressured drop listed in the table is that measured across the P-grid/bottom nozzle.

6RESSURIZED WATER REACTOR OWNERS GROUP

Page 37: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Results of Predictions

0.

0.0I-0w1~

InU,L.0.

a,(U

U(U

U

6

5.5

5

4.5

4

3.5

3

2.5

2

1.5

1

0.5

00 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6

Measured Pressure Drop (psid)

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 38: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Conclusion

" Full-Area FA testing is not necessary- Fidelity/repeatability of subscale tests

- The scaling of the Subscale Facility adequately represents a full-area fuel assembly with acceptable distortion

- Trending of subscale results agrees with pressure drops fromfull-area FA testing done for WCAP-1 6793-NP, Rev. 2

° Therefore, Subscale Facility will be used to determinethe final debris limits

" However, core inlet geometry still needs to be evaluated

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 39: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Summary of Results - Final Limits

PRESSURIZED WATER REACTOR OWNERS GROUP

UI

Page 40: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Additional Subscale Testing

Testing with core inlet geometry- Determine effect of core inlet geometry

* Westinghouse 17x1 7 bottom nozzle/P-grid combination tested

- Particulate size Distribution 1- p:f ratio varied to determine limiting value- Range of flow rates examined- Range of fiber loads examined

PRESSURIZED WATER REACTOR OWNERS GROUP

Page 41: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Core Inlet Geo metry Tests

o Changed flow control to replicate behavior seen in the THanalyses.

12

---- Case 1

- -- Case 210 _ _ _ _ _ _

-- Case 3

8 -

, '4

2.-. -- "-

0 - _ _ _ _ _ _

0 5 10 15 20

dP (psid)

6 MRESR.I ZED WATER REACTOR OWNE

i

RS GROUP

Page 42: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Comparison of Results

" Limiting results for W bottom nozzle/P-grid geometry obtained at- Low flow rate- p:f = 12:1

* Limiting results for single spacer grid geometry obtained at- High flow rate- p:f - 40:1

" Therefore, the fuel entrance geometry plays a role in the debris bedformation and resulting pressure drop- Due to bed morphology and resulting capture efficiency

ýIPRESSURIZED WATER REACTOR OWNERS GROUP

Page 43: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Path Forward

Since entrance geometry plays a role in the final dP,additional work to evaluate other entrance geometries isneeded

- Will specifically test Areva FUELGUARD/HMP 17x1 7 fuel design

- Other entrance geometries that are sufficiently similar to 17x1 7W bottom nozzle OR 17x1 7 Areva FUELGUARD designs to becovered by the testing

RESSURIZED WATER REACTOR OWNERS GROUP

Page 44: PWROG Global Expertise • One Voice · Parametric Tests -Round 1 o 23 Test Series Completed * 95 Independent Tests * Broken into 2 Phases o ... uniform mix of A,B and 4 2 - 0 0 5

Recommended