ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified
ADVANTECH CO., LTD.
QA Test Report
VITA-350P
(Product Reliability Test)
Report No : 08S068A0
Report Date : September 18, 2008 _______________________ _____________________ ___________________
Issue Stamp
Charles Chang Manager of QA Department
Charles Chang Approval
Knight Hu Test Engineer
1
VITA-350P Table of Contents Report No.08S068A0
QA Lab Reliability test
1. Test item list …………………………………………………… 2 2. Product specification entry …………………………………… 3 3. Product configuration photo………………………………….. 4 4. High temperature operation test ……………………………… 11 5. Low temperature operation test ………………………………. 14 6. Power ON/OFF test ………………………………………….... 17 7. Cold start test……….………………………………………….. 20 8. Humidity test………………………………………………….. 24 9. High temperature/humidity storage test……………………… 27
10. Low temperature storage test…..…………………………….. 30 11. Thermal profile test……………………………………………. 33 12. Random vibration test…………………………………………. 37 13. Package vibration test…………………………………………. 43 14. Package drop test……………………………………………... 51 15. Shock test………………………………………………………. 63
2
VITA-350P Test Item List Report No.08S068A0
QA Lab Reliability test
Num. Test item Result Remark1 High temperature operation test Passed 2 Low temperature operation test Passed 3 Power ON/OFF test Passed 4 Cold start test Passed 5 Humidity test Passed 6 High temperature/humidity storage test Passed 7 Low temperature storage test Passed 8 Thermal profile test Passed
9 Random vibration test Passed 10 Package vibration test Passed 11 Package drop test Passed 12 Shock test Passed
3
VITA-350P Product Spec Entry Report No.08S068A0
QA Lab Reliability test Num Item Specification
1 CPU Xscale PXA255 200Mhz 2 Memory Winbond SDRAM W9825G6EH-6 LCD Display Toshiba I/O port COM Port x 1 (2 wire)
USB client LVDS port DI/O
HDD San disk On board flash H3 256MB Dimension ( Wx Hx D ) 121.3 x 83.01 x 30 mm (47.76" x 32.68" x 11.81") Weight 170 g (0.375 lb) Power supply VITA : input rating 12V @ 1.2A and 24V @ 0.6A
TREK: input rating 5V @ 1A and 3.3V @ 0.5A
4
VITA-350P Product Configuration Photo Report No.08S068A0
QA Lab Reliability test Photo I:
VITA-350P receive module right-front side view
5
VITA-350P Product Configuration Photo Report No.08S068A0
QA Lab Reliability test Photo II:
VITA-350P receive module left-rear side view
6
VITA-350P Product Configuration Photo Report No.08S068A0
QA Lab Reliability test Photo III:
VITA-350P receive module structure photo I
7
VITA-350P Product Configuration Photo Report No.08S068A0
QA Lab Reliability test Photo IV:
VITA-350P receive module structure photo II
8
VITA-350P Product Configuration Photo Report No.08S068A0
QA Lab Reliability test Photo V:
VITA-350P panel module front side view
9
VITA-350P Product Configuration Photo Report No.08S068A0
QA Lab Reliability test Photo VI:
VITA-350P panel module rear side view
10
VITA-350P Product Configuration Photo Report No.08S068A0
QA Lab Reliability test Photo VII:
VITA-350P panel module structure view
11
VITA-350P High Temp. Operation Test Report No.08S068A0
QA Lab Reliability test Test Date : August 7, 2008 ~ August 8, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition :
1. Test Temperature : 75℃ 2. Test Times : 24Hrs 3. Test Software: Using Dial-up connections to connect GPRS and GPS signal from
satellite and basic station in WinCE 4. Test Environment Curve :
Temp℃
75℃
25℃
time Hrs 0:0 2:00 26:00 28:00
12
VITA-350P High Temp. Operation Test Report No.08S068A0
QA Lab Reliability test
Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-D4L+-150-LN2 Date of Calibration : 05/05/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
2. The system should not have degradation in its performance.
Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be
smooth, and no deformed parts found. Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
13
VITA-350P High Temp. Operation Test Report No.08S068A0
QA Lab Reliability test Conclusion : Passed.
The VITA-350P meets high temperature operation test.
14
VITA-350P Low Temp. Operation Test Report No.08S068A0
QA Lab Reliability test Test Date : August 8, 2008 ~ August 9, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition :
1. Test Temperature : -20℃ 2. Test Times : 24Hrs 3. Test Software: Using Dial-up connections to connect GPRS and GPS signal
from satellite and basic station in WinCE 4. Test Environment Curve :
Temp℃
25℃
-20℃
Time Hrs
0:0 2:00 26:00 28:00
15
VITA-350P Low Temp. Operation Test Report No.08S068A0
QA Lab Reliability test
Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-D4L+-150-LN2 Date of Calibration : 05/14/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Performance Criteria : Electronic function check:
1.All system functions must be checked with appropriate testing programs and should pass the inspection.
2.The system should not have degradation in its performance.
Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be
smooth, and no deformed parts found. Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
16
VITA-350P Low Temp. Operation Test Report No.08S068A0
QA Lab Reliability test Conclusion : Passed.
The VITA-350P meets low temperature operation test.
17
VITA-350P Humidity Test Report No. 08S068A0
QA Lab Reliability test Test Date : August 9, 2008 ~ August 11, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-3 Testing procedures Test Ca : Damp Heat steady state Test Test Condition :
1. Test Temperature : 40℃ 2. Test Humidity : 95%
3. Test Times : 48Hrs 4. Test Software: Using Dial-up connections to connect GPRS and GPS signal
from satellite and basic station in WinCE 5. Test Environment Curve :
Humidity %
Temp℃
95%
40℃
25℃
50%
Time Hrs 0:00 1:00 49:00 50:00
18
VITA-350P Humidity Test Report No. 08S068A0
QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-D4L+-150-LN2 Date of Calibration : 05/05/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
2. The system should not have degradation in its performance.
Mechanical function check: 1. The switch button and cover slot should work properly without any
interference. 2. All screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be
smooth, and no deformed parts found. Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
19
VITA-350P Humidity Test Report No. 08S068A0
QA Lab Reliability test Conclusion : Passed.
The VITA-350P meets humidity test.
20
VITA-350P Power ON/OFF Test ReportNo.08S068A0
QA Lab Reliability test Test Date : August 12, 2008 ~ August 16, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test
IEC60068-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition :
1. Test Temperature: -20℃ and 75 ,℃ 2. Power ON / OFF time interval: On 1min, Off 1 min. at low temperature
On 1min, Off 30 sec. at high temperature 3. Number of test: 1000 times for each temperature 4. Test OS mode: Linux 5. Power ON / OFF time interval curve
75℃ condition -20℃ condition Power ON Power OFF Power ON time Power ON time 1 minute. 1 minute.
Power OFF time Power OFF time 30 seconds. 1 minute
21
VITA-350P Power ON/OFF Test ReportNo.08S068A0
QA Lab Reliability test
6. Test Environment Curve: (75℃) 1 2 998 999 1000 Times iiiiiiiiiiii 0:00 25:30
7. Test Environment Curve: (-20℃)
1 2 998 999 1000 Times iiiiiiiiiiii 0:00 34:00
Temp℃
75℃
Power ON
25℃
Power OFF
Time Hrs
Temp℃
25℃
Power ON
-5℃
Power OFF
Time Hrs
22
VITA-350P Power ON/OFF Test ReportNo.08S068A0
QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp Model : THS-D4L+-100 Date of Calibration : 03/06/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Test Data :
Test temperature Test times Test Result -20 ℃ 1000 times 1000 times pass
75 ℃ 1000 times 1000 times pass Performance Criteria : Electronic function check:
1. It could not failure any time during 1000 times testing. 2. All system functions must be checked with appropriate testing programs
and should pass the inspection. 3. The system should not have degradation in its performance.
Mechanical function check:
1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be
smooth, and no deformed parts found.
23
VITA-350P Power ON/OFF Test ReportNo.08S068A0
QA Lab Reliability test Test Result :
There is no failure time during 1000 times testing. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
Conclusion : Passed.
The VITA-350P meets power on/off test.
24
VITA-350P Cold Start Test ReportNo.08S068A0
QA Lab Reliability test Test Date : August 17, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition :
1. Test Temperature: -20℃ 2. Storage times: 4Hrs 3. Power ON / OFF time interval: On 1 minutes, Off 10 minutes 4. Number of test: 20 times 5. System loading: Windows XP
6. Power ON / OFF time interval curve Power ON Power OFF 4hours 1 mins. 10mins. Power Off time Power ON time
Power OFF time Repeat 20 cycles
VITA-350P Cold Start Test ReportNo.08S068A0
25
QA Lab Reliability test
7. Test Environment Curve: 1 2 18 19 20 Times iiii 0:0 1:45 5:45 9:45 11:30
Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-D4L+- 150-LN2 Date of Calibration : 05/05/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Temp℃
25℃
Power ON
-20℃
Power OFF
Time Hrs
26
VITA-350P Cold Start Test ReportNo.08S068A0
QA Lab Reliability test Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
2. The system should not have degradation in its performance. 3. It could not failure any time during 20 times testing.
Test Result :
There is no failure time during 20 times testing. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
Conclusion : Passed.
The VITA-350P meets cold start test.
27
VITA-350P High temp./humi. Storage test Report No.08S068A0
QA Lab Reliability test Test Date : August 18, 2008 ~ August 19,2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-3 Testing procedures
Test Ca : Damp heat steady state test Test Condition :
1. Test Temperature : 60℃ 2. Test Humidity : 95% 3. Test Times : 24Hrs 4. Test Environment Curve :
Humidity %
Temp℃
95%
60℃
25℃
50%
Time Hrs 0:00 1:00 25:00 26:00
28
VITA-350P High temp./humi. Storage test Report No.08S068A0
QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber
K.SON. CO. LTD. Model : THS-D4L+-150-LN2 Date of Calibration : 05/05/2008
Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
2. The system should not have degradation in its performance.
Mechanical function check: 1.The switch button covers, slot can work properly without any interference. 2.All screws are tighten up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be
smooth, and no deformed parts found. Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
29
VITA-350P High temp./humi. Storage test Report No.08S068A0
QA Lab Reliability test Conclusion :
Passed. The VITA-350P meets high temperature and humidity storage test.
30
VITA-350P Low Temp. Storage Test Report No.08S068A0
QA Lab Reliability test Test Date : August 19, 2008 ~ August 20, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : -40℃ 2. Test Times : 24Hrs 3. Test Environment Curve :
Temp℃
25℃
-40℃
Time Hrs
0:0 1:30 25:30 27:00
31
VITA-350P Low Temp. Storage Test Report No.08S068A0
QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber
K.SON. CO. LTD. Model : THS-D4L+-150-LN2 Date of Calibration : 05/05/2008
Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
2. The system should not have degradation in its performance.
Mechanical function check: 1.The switch button covers, slot can work properly without any interference. 2.All screws are tighten up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be
smooth, and no deformed parts found.
32
VITA-350P Low Temp. Storage Test Report No.08S068A0
QA Lab Reliability test Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
Conclusion : Passed.
The VITA-350P meets low temperature storage test.
33
VITA-350P Thermal Profile Test Report No. 08S068A0
QA Lab Reliability test Test Date : August 23, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference Advantech QA_Lab thermal profile testing procedures Test Condition : 1. Test Temperature : 31.4℃ 2. Test Times : Each temperature 6 Hrs 3. Test EUT under box with no air flow ambient
4. Test Software: Using Dial-up connections to connect GPRS and GPS signal from satellite and basic station in WinCE
Test Equipment : DATA LOGGER YOKOGAWA CO. LTD. Model : uP-1800 S/N : 47XS0063 Date of Calibration : 9/12/2007
VITA-350P Thermal Profile Test Report No. 08S068A0
34
QA Lab Reliability test Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
2. The system should not have degradation in its performance. Mechanical function check:
1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be
smooth, and no deformed parts found.
35
VITA-350P Thermal Profile Test Report No. 08S068A0
QA Lab Reliability test Test Data :
NUM Parts List Measurement
31.4℃
Calculation
70℃
SEPC.
1. Ublox LEA-5S-0-002 45.6 84.2 85 (Tc)
2. Infineon PMB 7850E 47.4 86.0 90 (Tc)
3. W9825G6EH-6 47.3 85.9 90 (Tc)
4. Intel PXA255A0C 200 46.5 84.8 85 (Tc)
5. DS90C385A 49.2 85.1 70 (Ta)
6. DS90C3854 (Panel) 39.8 78.4 85 (Ta)
Remark :
Ta : Ambient temperature specification Tc : Device Case temperature specification Advantech define : Tc = Ta +20C Test Result :
1. The system specification of thermal profile is 70 degree C. 2. There is no damage in electronic functions or degradation has not been
found. 3. Performance is maintained with no incurable physical damage or
degradation. Conclusion : Passed
The VITA-350P meets thermal profile test.
36
VITA-350P Thermal Profile Test Report No. 08S068A0
QA Lab Reliability test Photo:
VITA-350P test photo
37
VITA-350P Random vibration operation test Report No.08S068A0
QA Lab Reliability test Test Date : September 8, 2008 Test Site : Integrated Service Technology Inc. Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference MIL-STD-810F 514.5C-3 Testing procedures Test Condition :
1. Test Acceleration: X axis 1.62Grms, Y axis 2.05grms, Z axis 2.2Grms 2. Test Frequency : 5-500Hz 3. Test Axis : X, Y, Z axis 4. Test Time : 1hr per axis
5. Test Software: Using Dial-up connections to connect GPRS and GPS signal from satellite and basic station in WinCE
6. Test Vibration Curve :
38
VITA-350P Random vibration operation test Report No.08S068A0
QA Lab Reliability test
39
VITA-350P Random vibration operation test Report No.08S068A0
QA Lab Reliability test Test Equipment : Vibration Simulator System
SHINKEN G-0230N Shake system. S / N: SG-4345 Date of Calibration: 03/19/2008
Vibration Simulator System
SHINKEN G-0250L Shake system. S / N: SG-4795 Date of Calibration: 06/06/2008
Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
2. The system should not have degradation in its performance.
Mechanical function check: 1. The switch button ,covers can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be
smooth, and no deformed parts found.
40
VITA-350P Random vibration operation test Report No.08S068A0
QA Lab Reliability test Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
Conclusion :
Passed. The VITA-350P meets random vibration operation test.
PHOTO I:
VITA-350P Random vibration test Z axis
41
VITA-350P Random vibration operation test Report No.08S068A0
QA Lab Reliability test PHOTO II:
VITA-350P Random vibration test Y axis
42
VITA-350P Random vibration operation test Report No.08S068A0
QA Lab Reliability test PHOTO III:
VITA-350P Random vibration test X axis
43
VITA-350P Package Vibration Test Report No.08S068A0
QA Lab Reliability test Test Date : September 27, 2007; September 8, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-64 Testing procedures Test Fh : Vibration broadband random test Test Condition : 1. Test PSD : 0.026G²/Hz (2.16Grms) 2. Test Frequency : 5-500Hz 3. Test Axis : X,Y and Z axis 4. Test Time : 30 minutes per axis 5. Test Curve :
Acceleration 2.16Grms -6db/oct
PSD 0.026g²/Hz
5Hz 100Hz 500Hz
44
VITA-350P Package Vibration Test Report No.08S068A0
QA Lab Reliability test
Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model: 9363EM-800F2K-40N120 S / N: MC107142493 Date of Calibration: 07/09/2008
Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
2. The system should not have degradation in its performance. Mechanical function check:
1. The switch button covers can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be
smoothes, and no deformed parts found.
45
VITA-350P Package Vibration Test Report No.08S068A0
QA Lab Reliability test Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
Conclusion : Passed.
The VITA-350P System meets package vibration test. PHOTO I:
VITA-350P package vibration test Z axis
46
VITA-350P Package Vibration Test Report No.08S068A0
QA Lab Reliability test PHOTO II:
VITA-350P package vibration test X axis
47
VITA-350P Package Vibration Test Report No.08S068A0
QA Lab Reliability test PHOTO III:
VITA-350P package vibration test Y axis
48
VITA-350P Package Vibration Test Report No.08S068A0
QA Lab Reliability test PHOTO IV:
VITA-350P(panel) package vibration test X axis
49
VITA-350P Package Vibration Test Report No.08S068A0
QA Lab Reliability test PHOTO V:
VITA-350P(panel) package vibration test Y axis
50
VITA-350P Package Vibration Test Report No.08S068A0
QA Lab Reliability test PHOTO VI:
VITA-350P(panel) package vibration test Z axis
51
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test Test Date : August 19, 2007; September 10, 2008 Test Site : Advantech QA Environment Lab Performed By: Knight Hu Purpose : The DVT test Test Standard : Reference Federal Standard 101 Method 5007 Testing procedure B
Test Ea : Drop Test Test Condition (Receive module):
1. Test Phase : One corner Three edges Six faces
2. Test High : 100cm 3. Package Weight : 600 g 4. Package Dimension : 25.5cm× 18.0cm× 6.0cm 5. Test Drawing :
Topside Rear Side Left Side Right Side Bottom Side Mid Edge Front Side Short Edge Long Edge Damage Corner
52
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test Test Condition (Panel module):
1. Test Phase: One corner Three edges
Six faces 2. Test High : 100cm 3. Package Weight : 1.1K g 4. Package Dimension : 32.0cm× 23.5cm× 10.5cm 5. Test Drawing :
Topside Rear Side Left Side Right Side Bottom Side Mid Edge Front Side Short Edge Long Edge Damage Corner Test Equipment : Drop Tester Machine YOSHIDA SEIKI Co. LTD. Model : DT-100B
53
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate programs and should pass the inspection.
Mechanical function check:
1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately.
3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the board enclosure must be smooth,
and no deformed parts should be found. Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
Conclusion :
Passed. The VITA-350P meets package drop test.
54
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test PHOTO I:
VITA-350P structure photo
55
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test
PHOTO II:
VITA-350P corner test photo
56
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test
PHOTO III:
VITA-350P edge test photo
57
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test PHOTO IV:
VITA-350P face test photo
58
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test PHOTO V:
VITA-350P(panel) corner test photo
59
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test PHOTO VI:
VITA-350P(panel) edge test photo
60
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test PHOTO VII:
VITA-350P(panel) face test photo
61
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test PHOTO VIII:
VITA-350P(panel) structure photo
62
VITA-350P Package drop Test Report No.08S068A0
QA Lab Reliability test PHOTO IX:
VITA-350P(panel) structure photo
63
VITA-350P Shock Test ReportNo.08S068A0
QA Lab Reliability test Test Date : August 8, 2008 Test Site : Integrated Service Technology Lab. Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-27 testing procedures
Test Ea : Shock test Test Condition :
1. Test condition: Operation, using Dial-up connections to connect GPRS and GPS signal from satellite and basic station in WinCE
2. Test pulse shape : half sine wave 3. Test acceleration 50G, pulse duration 11 ms 4. Test method : six faces (front, rear, left, right, top & bottom side)
three times per side 5. Test Curve :
Half Sine Wave
11ms Pulse Duration time
Shock Acceleration 50G
64
VITA-350P Shock Test ReportNo.08S068A0
QA Lab Reliability test Test Equipment : LAB AUTO-SHOCK II 2432 Shock tester
Serial Number : 181028 Date of Calibration: 03/19/2008
Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :
1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V
Performance Criteria : Electronic function check:
1. All system functions must be checked with appropriate testing programs and should pass the inspection.
Mechanical function check:
1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.
3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the system enclosure or mechanical parts must be smooth ,and no deformed parts should be found. Test Result :
There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.
Conclusion : Passed.
The VITA-350P meets shock test.
65
VITA-350P Shock Test ReportNo.08S068A0
QA Lab Reliability test PHOTO I:
VITA-350P shock test for bottom side
66
VITA-350P Shock Test ReportNo.08S068A0
QA Lab Reliability test PHOTO II:
VITA-350P shock test for top side
67
VITA-350P Shock Test ReportNo.08S068A0
QA Lab Reliability test PHOTO III:
VITA-350P shock test for right side
68
VITA-350P Shock Test ReportNo.08S068A0
QA Lab Reliability test PHOTO IV:
VITA-350P shock test for left side
69
VITA-350P Shock Test ReportNo.08S068A0
QA Lab Reliability test PHOTO V:
VITA-350P shock test for rear side
70
VITA-350P Shock Test ReportNo.08S068A0
QA Lab Reliability test PHOTO VI:
VITA-350P shock test for front side