    FACETBill of Quantities

    Office Building For

    Insurance Regulatory Development Authority

    Hyderabad

    Office Building For IRDA

    Architect : EDIFICE Architects

    08 April 2010

    S.NO. DECRIPTION UNIT RATE AMOUNT

    IRDA Office Building - Split B.O.Q.

    a.1.5 Structurally Glazed Door

    Extra over a.1 above for Structurally glazed door including approved hardware of multi-point (four) locking

    system with provision for Master key included, S.S.lock from inside with handle of approved colour from

    approved make.All prices to be inclusive of all Taxes, Statutory requirements, etc.

    SQM

    a.1.6 Back-pan for Spandrel Glass

    Extra Over a.1 & a.2 Providing & fixing Rock wool of approved make of 50mm Thk. (Density : 48 Kg. / M3)

    insulation of approved sample / make with Woven Fabric Black veil enclosed in a 1.2mm thk. G.I. back pan with

    SS 304 hardware. All prices to be inclusive of all Taxes, Statutory requirements, etc.

    SQM 1,305.00 1,305.00

    Certification will be based on actual measurement at si te.

    a.1.7 Fire stop Smoke seal

    Extra Over a.1 Providing & fixing rock wool (Density : 100 Kg. / M3) insulation of approved sample / make

    enclosed in a 2mm thk. G.I. sheet support sealed with fire stop silicone of approved make to the structure and

    fixed with SS 304 hardware, fire rated Anchors of Hilt/Fischer make as per concept drawings. All prices to be

    inclusive of all Taxes, Statutory requirements, etc.

    RMT 522.00 522.00

    Certification will be based on actual measurement at si te.

    a.1.8 Flashing

    Extra Over a.1 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved make to thestructure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory requirements, etc. RMT 522.00 522.00

    Certification will be based on actual measurement at si te.

    a.1.9 ACP Coping

    Extra Over a.1 Providing & fixing 4 mm thick ACP sheet of approved make & color with 1.2mm thk. G.I. sheet

    flashing inside, sealed by silicone of approved make to the structure and fixed with SS 304 hardware. All prices

    SQM 3,204.00 3,204.00

    Certification will be based on actual measurement at si te.

    Total

    Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 4 of 13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    5/13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    6/13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    7/13

    FACETBill of Quantities

    Office Building For

    Insurance Regulatory Development Authority

    Hyderabad

    Office Building For IRDA

    Architect : EDIFICE Architects

    08 April 2010

    S.NO. DECRIPTION UNIT RATE AMOUNT

    IRDA Office Building - Split B.O.Q.

    a.5.2 Glass

    a.5.2.1 Option-1 - Dark Blue -Glaverbel Make- 6mm Sunergy Dark Blue + 12mm air gap + 6mm Clear low-e (SHGC-

    0.25 , 35% VLT & U- 1.6 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.

    SQM 5,310.00 5,310.00

    a.5.2.2 Option-2 - Blue Green -Saint Goblin Make-ST450-6mm #2 low-E + 12mm Airgap+6mm #3 low-E Glass (SHGC-

    0.25 , 35% VLT & U- 1.77 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.

    SQM 5,220.00 5,220.00

    a.5.2.3 Option-3 - Blue - Emirates Glass-SOLITE-STRATUS 39/23-6mm Low-E + 12mm air gap + 6mm Clear (SHGC-

    0.23 , 39% VLT & U- 1.3 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.

    SQM 5,508.00 5,508.00

    a.5.3 Flashing

    Extra Over a.4 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved make to the

    structure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory requirements, etc. RMT 1,206.00 1,206.00

    Certification will be based on actual measurement at si te.

    Total

    a.6 Entrance Glass Canopy

    a.6.1 Design,fabricate, deliver (to job site) and install steel structure for the entrance glass porch as per approved

    Shop DWGs. Including Epoxy coating, anti rust PU Paint in 3 coats as directed finished complete.

    MT 85,050.00 85,050.00

    Certification will be based on actual measurement at si te .

    a.6.2 Design,fabricate, package, deliver (to Job site) and installation of S.S. 316 spider of approved make as per

    structural calculations & *13.52mm Laminated Glass comprising of 6mm thk. Heat Strengthened Glass + 1.52

    Clear PVB + 6mm thk. Clear Heat Strengthened Glass (downside) as per concept dwgs. The detailed

    specifications including erection & removal of scaffolding, cleaning the Facade & testing. All prices to be

    inclusive of all Taxes, Statutory requirements, etc. Only Glass area will be measured & paid for.

    SQM 12,510.00 12,510.00

    Certification will be based on actual measurement at si te .

    Total

    Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 7 of 13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    8/13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    9/13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    10/13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    11/13

    FACETBill of Quantities

    Office Building For

    Insurance Regulatory Development Authority

    Hyderabad

    Office Building For IRDA

    Architect : EDIFICE Architects

    08 April 2010

    S.NO. DECRIPTION UNIT RATE AMOUNT

    IRDA Office Building - Split B.O.Q.

    C Pre Cast Concrete Panel Cladding

    c.1 Supply & installation of pre cast concrete panel of 100mm thick (Gray/Approved) on base structure using steel

    hot dip galvanised clamps/brackets with 15 to 20 mm wide Closed joints with non staining silicone sealant as

    joint filler. Note that silicone compatibility is to be checked with the specified concrete panel, if required

    appropriate Primer/Sealer to be used prior to silicone application as per approved shop drawing and structural

    adequacy. The anchoring / bracing of the pre cast concrete panel cladding to the RCC slab / beams / columns

    shall be done with non-corrosive brackets of approved design including providing teflon shims of various

    thickness to adjust the beam level / line variations. The Rate shall include for die preparation,odd size panels

    manufacturing,modification on panels to required sizes, making cut-outs. All screws, bolts, nuts and washers

    used shall be only stainless steel of 304 grade. The contractor must design the system as per the prevalent siteconditions and building elevation profiles. No extra claims shall be entertained at any stage. Quote in

    compliance with Shop Drawings and specifications noted herein including transportation, handling, erection &

    removal of scaffolding, cleaning the Facade.Rates also should include lab performance testing, site

    performance testing, 40 Sq.m mockup prior to start the work. The Contractor must quote rates accordingly. All

    c.1.1 Supply & installation of 1057mm x 4200mm pre cast concrete panel of 100mm thick (Gray/Approved) on base

    structure as per the apecifications.SQM NA NA

    c.1.2 Supply & installation of pre cast concrete panel (Gray/Approved) on soffit / ceilings / roofs as per the

    apecifications

    SQM NA NA

    c.1.3 Supply & installation of pre cast concrete panel (Gray/Approved) on coping / projected fins as per the

    apecificationsSQM NA NA

    c.1.4 Supply & installation of pre cast concrete panel tiles (Gray/Approved) on internal walls / Corridors as per the

    apecificationsSQM NA NA

    c.1.5 Supply & installation of fluted pre cast concrete panel tiles (Gray/Approved) on internal walls / Corridors as per

    the apecificationsSQM NA NA

    Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 11 of 13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    12/13

    FACETBill of Quantities

    Office Building For

    Insurance Regulatory Development Authority

    Hyderabad

    Office Building For IRDA

    Architect : EDIFICE Architects

    08 April 2010

    S.NO. DECRIPTION UNIT RATE AMOUNT

    IRDA Office Building - Split B.O.Q.

    Insulation

    c.2 Extra Over c.1.1,c.1.2 & c.1.3 Providing & fixing rock wool 50mm Thk. (Density : 48 Kg. / M3) insulation of

    approved sample / make with aluminium foil of 150 micron. All prices to be inclusive of all Taxes, Statutory

    requirements, etc.

    SQM 315.00 315.00

    Certification will be based on actual measurement at si te.

    Certification will be based on actual measurement at si te.

    Fire Stopper

    c.3 Extra Over c.1.1 Providing & fixing rock wool (Density : 100 Kg. / M3) insulation of approved sample / make

    enclosed in a 2mm thk. G.I. sheet support sealed with fire stop silicone of approved make to the structure and

    fixed with SS 304 hardware, fire rated Anchors of Hilt/Fischer make as per concept drawings. All prices to beinclusive of all Taxes, Statutory requirements, etc.

    RMT 522.00 522.00

    Certification will be based on actual measurement at si te.

    Flashing

    c.4 Extra Over c.1.1 & c.1.2 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved

    make to the structure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory

    requirements, etc.

    RMT 522.00 522.00

    Certification will be based on actual measurement at si te.

    Steel Supportc.5 Design,fabricate, deliver (to job site) and install steel structure for precast concrete panels support as per

    approved Shop DWGs. Including Epoxy coating, anti rust PU Paint in 3 coats as directed finished complete. MT NA NA

    Certification will be based on actual measurement at si te.

    Total

    Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 12 of 13

  • 8/9/2019 Quatation for IRDA Office-APIIC

    13/13

    FACETBill of Quantities

    Office Building For

    Insurance Regulatory Development Authority

    Hyderabad

    Office Building For IRDA

    Architect : EDIFICE Architects

    08 April 2010

    S.NO. DECRIPTION UNIT RATE AMOUNT

    IRDA Office Building - Split B.O.Q.

    D Faade Access and Cleaning System

    F Operational Manual

    f.1 System provided by the contractor has to be approved by the faade consultant . If the system is already tested

    in the laboratory, proper testing certificates are required to be submitted and approved by the faade consultant.

    If not tested ,the system has to be tested at any certified laboratory (Indian/Overseas)in presence of facade

    consultant.f.2 Test certificates for all accessories like screws, anchor bolts, silicon sealant, EPDM Gaskets etc must be

    provided

    f.3 Dow Corning representatives has to perform deglazing test on the glazing unit of selected contractor

    f.4 Anchor bolt pull out test has to be carried out on site before starting the installation.

    f.5 Mock installed by the awarded contractor need to be approved from the facade consultant before carrying out

    the installation. The mock up will be a permant mock up based on the grid/reference point.

    f.6 PVDF coating has to be tested at the factory of the coaters in presence of faade consultant

    f.7 The processing unit of the glass processor will be inspected by the client/ faade consultant before starting the

    work

    f.8 Contractor shall provide back to back guarantee on all the accessories used in the system

    f.9 Additional items may come during later stage based on architect approvals

    f.10 Certification will be based on actual measurement at site. All taxes will be inclusive. Any variation has to be

    approved by the faade consultant

    Testing of Faade

    No additional claim will be paid to awarded contractor for laboratory testing and site testing of installed

    faade directed by FACET as per AAMA .

    Name, Sign & Seal of the Contractor :