of 13
8/9/2019 Quatation for IRDA Office-APIIC
1/13
8/9/2019 Quatation for IRDA Office-APIIC
2/13
8/9/2019 Quatation for IRDA Office-APIIC
3/13
8/9/2019 Quatation for IRDA Office-APIIC
4/13
FACETBill of Quantities
Office Building For
Insurance Regulatory Development Authority
Hyderabad
Office Building For IRDA
Architect : EDIFICE Architects
08 April 2010
S.NO. DECRIPTION UNIT RATE AMOUNT
IRDA Office Building - Split B.O.Q.
a.1.5 Structurally Glazed Door
Extra over a.1 above for Structurally glazed door including approved hardware of multi-point (four) locking
system with provision for Master key included, S.S.lock from inside with handle of approved colour from
approved make.All prices to be inclusive of all Taxes, Statutory requirements, etc.
SQM
a.1.6 Back-pan for Spandrel Glass
Extra Over a.1 & a.2 Providing & fixing Rock wool of approved make of 50mm Thk. (Density : 48 Kg. / M3)
insulation of approved sample / make with Woven Fabric Black veil enclosed in a 1.2mm thk. G.I. back pan with
SS 304 hardware. All prices to be inclusive of all Taxes, Statutory requirements, etc.
SQM 1,305.00 1,305.00
Certification will be based on actual measurement at si te.
a.1.7 Fire stop Smoke seal
Extra Over a.1 Providing & fixing rock wool (Density : 100 Kg. / M3) insulation of approved sample / make
enclosed in a 2mm thk. G.I. sheet support sealed with fire stop silicone of approved make to the structure and
fixed with SS 304 hardware, fire rated Anchors of Hilt/Fischer make as per concept drawings. All prices to be
inclusive of all Taxes, Statutory requirements, etc.
RMT 522.00 522.00
Certification will be based on actual measurement at si te.
a.1.8 Flashing
Extra Over a.1 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved make to thestructure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory requirements, etc. RMT 522.00 522.00
Certification will be based on actual measurement at si te.
a.1.9 ACP Coping
Extra Over a.1 Providing & fixing 4 mm thick ACP sheet of approved make & color with 1.2mm thk. G.I. sheet
flashing inside, sealed by silicone of approved make to the structure and fixed with SS 304 hardware. All prices
SQM 3,204.00 3,204.00
Certification will be based on actual measurement at si te.
Total
Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 4 of 13
8/9/2019 Quatation for IRDA Office-APIIC
5/13
8/9/2019 Quatation for IRDA Office-APIIC
6/13
8/9/2019 Quatation for IRDA Office-APIIC
7/13
FACETBill of Quantities
Office Building For
Insurance Regulatory Development Authority
Hyderabad
Office Building For IRDA
Architect : EDIFICE Architects
08 April 2010
S.NO. DECRIPTION UNIT RATE AMOUNT
IRDA Office Building - Split B.O.Q.
a.5.2 Glass
a.5.2.1 Option-1 - Dark Blue -Glaverbel Make- 6mm Sunergy Dark Blue + 12mm air gap + 6mm Clear low-e (SHGC-
0.25 , 35% VLT & U- 1.6 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.
SQM 5,310.00 5,310.00
a.5.2.2 Option-2 - Blue Green -Saint Goblin Make-ST450-6mm #2 low-E + 12mm Airgap+6mm #3 low-E Glass (SHGC-
0.25 , 35% VLT & U- 1.77 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.
SQM 5,220.00 5,220.00
a.5.2.3 Option-3 - Blue - Emirates Glass-SOLITE-STRATUS 39/23-6mm Low-E + 12mm air gap + 6mm Clear (SHGC-
0.23 , 39% VLT & U- 1.3 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.
SQM 5,508.00 5,508.00
a.5.3 Flashing
Extra Over a.4 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved make to the
structure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory requirements, etc. RMT 1,206.00 1,206.00
Certification will be based on actual measurement at si te.
Total
a.6 Entrance Glass Canopy
a.6.1 Design,fabricate, deliver (to job site) and install steel structure for the entrance glass porch as per approved
Shop DWGs. Including Epoxy coating, anti rust PU Paint in 3 coats as directed finished complete.
MT 85,050.00 85,050.00
Certification will be based on actual measurement at si te .
a.6.2 Design,fabricate, package, deliver (to Job site) and installation of S.S. 316 spider of approved make as per
structural calculations & *13.52mm Laminated Glass comprising of 6mm thk. Heat Strengthened Glass + 1.52
Clear PVB + 6mm thk. Clear Heat Strengthened Glass (downside) as per concept dwgs. The detailed
specifications including erection & removal of scaffolding, cleaning the Facade & testing. All prices to be
inclusive of all Taxes, Statutory requirements, etc. Only Glass area will be measured & paid for.
SQM 12,510.00 12,510.00
Certification will be based on actual measurement at si te .
Total
Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 7 of 13
8/9/2019 Quatation for IRDA Office-APIIC
8/13
8/9/2019 Quatation for IRDA Office-APIIC
9/13
8/9/2019 Quatation for IRDA Office-APIIC
10/13
8/9/2019 Quatation for IRDA Office-APIIC
11/13
FACETBill of Quantities
Office Building For
Insurance Regulatory Development Authority
Hyderabad
Office Building For IRDA
Architect : EDIFICE Architects
08 April 2010
S.NO. DECRIPTION UNIT RATE AMOUNT
IRDA Office Building - Split B.O.Q.
C Pre Cast Concrete Panel Cladding
c.1 Supply & installation of pre cast concrete panel of 100mm thick (Gray/Approved) on base structure using steel
hot dip galvanised clamps/brackets with 15 to 20 mm wide Closed joints with non staining silicone sealant as
joint filler. Note that silicone compatibility is to be checked with the specified concrete panel, if required
appropriate Primer/Sealer to be used prior to silicone application as per approved shop drawing and structural
adequacy. The anchoring / bracing of the pre cast concrete panel cladding to the RCC slab / beams / columns
shall be done with non-corrosive brackets of approved design including providing teflon shims of various
thickness to adjust the beam level / line variations. The Rate shall include for die preparation,odd size panels
manufacturing,modification on panels to required sizes, making cut-outs. All screws, bolts, nuts and washers
used shall be only stainless steel of 304 grade. The contractor must design the system as per the prevalent siteconditions and building elevation profiles. No extra claims shall be entertained at any stage. Quote in
compliance with Shop Drawings and specifications noted herein including transportation, handling, erection &
removal of scaffolding, cleaning the Facade.Rates also should include lab performance testing, site
performance testing, 40 Sq.m mockup prior to start the work. The Contractor must quote rates accordingly. All
c.1.1 Supply & installation of 1057mm x 4200mm pre cast concrete panel of 100mm thick (Gray/Approved) on base
structure as per the apecifications.SQM NA NA
c.1.2 Supply & installation of pre cast concrete panel (Gray/Approved) on soffit / ceilings / roofs as per the
apecifications
SQM NA NA
c.1.3 Supply & installation of pre cast concrete panel (Gray/Approved) on coping / projected fins as per the
apecificationsSQM NA NA
c.1.4 Supply & installation of pre cast concrete panel tiles (Gray/Approved) on internal walls / Corridors as per the
apecificationsSQM NA NA
c.1.5 Supply & installation of fluted pre cast concrete panel tiles (Gray/Approved) on internal walls / Corridors as per
the apecificationsSQM NA NA
Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 11 of 13
8/9/2019 Quatation for IRDA Office-APIIC
12/13
FACETBill of Quantities
Office Building For
Insurance Regulatory Development Authority
Hyderabad
Office Building For IRDA
Architect : EDIFICE Architects
08 April 2010
S.NO. DECRIPTION UNIT RATE AMOUNT
IRDA Office Building - Split B.O.Q.
Insulation
c.2 Extra Over c.1.1,c.1.2 & c.1.3 Providing & fixing rock wool 50mm Thk. (Density : 48 Kg. / M3) insulation of
approved sample / make with aluminium foil of 150 micron. All prices to be inclusive of all Taxes, Statutory
requirements, etc.
SQM 315.00 315.00
Certification will be based on actual measurement at si te.
Certification will be based on actual measurement at si te.
Fire Stopper
c.3 Extra Over c.1.1 Providing & fixing rock wool (Density : 100 Kg. / M3) insulation of approved sample / make
enclosed in a 2mm thk. G.I. sheet support sealed with fire stop silicone of approved make to the structure and
fixed with SS 304 hardware, fire rated Anchors of Hilt/Fischer make as per concept drawings. All prices to beinclusive of all Taxes, Statutory requirements, etc.
RMT 522.00 522.00
Certification will be based on actual measurement at si te.
Flashing
c.4 Extra Over c.1.1 & c.1.2 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved
make to the structure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory
requirements, etc.
RMT 522.00 522.00
Certification will be based on actual measurement at si te.
Steel Supportc.5 Design,fabricate, deliver (to job site) and install steel structure for precast concrete panels support as per
approved Shop DWGs. Including Epoxy coating, anti rust PU Paint in 3 coats as directed finished complete. MT NA NA
Certification will be based on actual measurement at si te.
Total
Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 12 of 13
8/9/2019 Quatation for IRDA Office-APIIC
13/13
FACETBill of Quantities
Office Building For
Insurance Regulatory Development Authority
Hyderabad
Office Building For IRDA
Architect : EDIFICE Architects
08 April 2010
S.NO. DECRIPTION UNIT RATE AMOUNT
IRDA Office Building - Split B.O.Q.
D Faade Access and Cleaning System
F Operational Manual
f.1 System provided by the contractor has to be approved by the faade consultant . If the system is already tested
in the laboratory, proper testing certificates are required to be submitted and approved by the faade consultant.
If not tested ,the system has to be tested at any certified laboratory (Indian/Overseas)in presence of facade
consultant.f.2 Test certificates for all accessories like screws, anchor bolts, silicon sealant, EPDM Gaskets etc must be
provided
f.3 Dow Corning representatives has to perform deglazing test on the glazing unit of selected contractor
f.4 Anchor bolt pull out test has to be carried out on site before starting the installation.
f.5 Mock installed by the awarded contractor need to be approved from the facade consultant before carrying out
the installation. The mock up will be a permant mock up based on the grid/reference point.
f.6 PVDF coating has to be tested at the factory of the coaters in presence of faade consultant
f.7 The processing unit of the glass processor will be inspected by the client/ faade consultant before starting the
work
f.8 Contractor shall provide back to back guarantee on all the accessories used in the system
f.9 Additional items may come during later stage based on architect approvals
f.10 Certification will be based on actual measurement at site. All taxes will be inclusive. Any variation has to be
approved by the faade consultant
Testing of Faade
No additional claim will be paid to awarded contractor for laboratory testing and site testing of installed
faade directed by FACET as per AAMA .
Name, Sign & Seal of the Contractor :
Quantities Noted are indicative. Tenderer to remeasure and quote prices.www.facet-fe.com 13 of 13