INDUSTRIAL AUTOMATION
Interactive Graphical SCADA System
INSIGHT AND OVERVIEW
QUICK STARTGUIDE
8/12/2019 QuickStartGuide_Free50
2/27
Page 1 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
Quick Start Guide for IGSS FREE50
IntroductionThis guide is intended to get you up and running with the IGSS FREE50 license as fast as possible. It provides
a quick route through the workflow:
ContentsIntroduction ....................................................................................................................................................... 1
STEP 1. Installing and updating IGSS .............................................................................................................. 2
STEP 2. Setting up a new IGSS configuration ............................................................................................... 10
STEP 3. Creating a process diagram in the design module ......................................................................... 16STEP 4. Creating your first process component ........................................................................................... 18
STEP 5. Running the configuration ............................................................................................................... 25
For more detailed documentation of IGSS, please refer to the Getting Started manual and the IGSS help
files.
8/12/2019 QuickStartGuide_Free50
3/27
Page 2 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
STEP 1. Installing and updating IGSS
1) Right-click the downloaded file, IGSS80_Full.zip, and select Extract All.
2) Open the extracted folder and open the cdimagefolder. Double-click on StartInstall.exe .
8/12/2019 QuickStartGuide_Free50
4/27
Page 3 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
3) Click Yesto install IGSS. The IGSS32 V8.0Installer Progress should now appear.
4) Click Next when the Install Wizard opens.
8/12/2019 QuickStartGuide_Free50
5/27
Page 4 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
5) Click Next.
6) Select I accept the terms in the license agreement and click Next.
7) Click Next.
8/12/2019 QuickStartGuide_Free50
6/27
Page 5 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
8) If you do not have an SQL Server installed, select Install Microsoft SQL Server 2005 Express. Click
Next.
9) If you do not have Microsoft Access 2003 or higher, select Install Access Runtime. Click Next.
8/12/2019 QuickStartGuide_Free50
7/27
Page 6 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
10)Select Completeand click Next.
11)Click Install. The installation process should now begin.
8/12/2019 QuickStartGuide_Free50
8/27
Page 7 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
12)Click Yeswhen the IGSS Station Typedialog is opened.
13)Select IGSS FREE50and click Next.
Nyt billede !!!
14)Click Finish.
8/12/2019 QuickStartGuide_Free50
9/27
8/12/2019 QuickStartGuide_Free50
10/27
Page 9 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
18)Click Finish.
19)Click Yes.
8/12/2019 QuickStartGuide_Free50
11/27
Page 10 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
STEP 2. Setting up a new IGSS configuration
1) Click StartAll ProgramsIGSS 8.0System Configuration.
2) Click the New Configuration Wizardbutton.
8/12/2019 QuickStartGuide_Free50
12/27
Page 11 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
3) Click Next.
4) Select Create a new configuration.
8/12/2019 QuickStartGuide_Free50
13/27
Page 12 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
5) Give your configuration a name and specify a location. Click Next.
6) Select the station type Single Userand click Next.
8/12/2019 QuickStartGuide_Free50
14/27
Page 13 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
7) Do the following:
a) Start by clicking the button New driverand select the relevant driver from the list.
b) Click New interfaceto specify the connection type (COM port, modem or radio).
c) Click New nodefor the number of PLCs you want to set up. A node in IGSS corresponds to a
physical PLC.
Details about hardware and software requirements for PLC connections are available at the 7T
websitehttp://www.7t.dk/igss/default.asp?showid=44.
http://www.7t.dk/igss/default.asp?showid=44http://www.7t.dk/igss/default.asp?showid=44http://www.7t.dk/igss/default.asp?showid=44http://www.7t.dk/igss/default.asp?showid=448/12/2019 QuickStartGuide_Free50
15/27
Page 14 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
8) The initial setup is now completed. Click the Finishbutton.
9) Select the DemoStationname. The screen of the computer icon should turn green. If not, right-
click the icon and select This PCin the popup menu.
8/12/2019 QuickStartGuide_Free50
16/27
Page 15 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
10)Select the Data Collectiontab.
If you want to communicate with a real PLC, make sure that Run simulatedis NOT selected.
If you want to run simulated, select the check box.
11)In the Filemenu, click Save and start Definition.
8/12/2019 QuickStartGuide_Free50
17/27
Page 16 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
STEP 3. Creating a process diagram in the design module
1) In the Areamenu, select Create.
2) Define an area namedo NOT use spaces in the name.
8/12/2019 QuickStartGuide_Free50
18/27
Page 17 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
3) In the Diagrammenu, select Create.
4) Define a diagram name and select the check boxes as shown below.
8/12/2019 QuickStartGuide_Free50
19/27
Page 18 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
STEP 4. Creating your first process component
1) Click Objects-> Create -> By Using Object Wizard.
2) Select the Analogoption, enter an object name and click Next.
8/12/2019 QuickStartGuide_Free50
20/27
Page 19 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
3) Now it is time to set up the PLC addresses of the individual atoms (I/O points).
By default, the Actual Value, Set Point, High Alarm and Low Alarm are enabled.
As an example, weve selected the Actual Value atom. To specify its PLC address, start by
clicking the Driver specific addressingbutton. Then enter the specific address in the Driver
Specific Addressingdialog box.
Repeat this procedure for the remaining atoms.
4) Define the alarm limit values and corresponding alarm texts. To create an alarm text, click in the
Alarm Textcolumn and select New alarm text.
8/12/2019 QuickStartGuide_Free50
21/27
Page 20 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
5) Select the relevant scan interval for the process component (IGSS object). How often do you want
to read the process value from the PLC?
6) Select the relevant data reductions and intervals. The data reduction values can be viewed in IGSS
graphs and form the data basis of IGSS standard reports.
8/12/2019 QuickStartGuide_Free50
22/27
Page 21 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
7) Select what data you want to record in the IGSS LOG files. In this case, all changes are registered
including outgoing commands issued by the operator. The LOG data can be viewed in IGSS graphs.
8) Specify how you want to display the object and its process values on the diagram.
8/12/2019 QuickStartGuide_Free50
23/27
Page 22 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
9) Click Finishand the analog object appears on the diagram in the design module.
10)In the Format menu, select Set Initial Displayto set this diagram as the startup picture.
8/12/2019 QuickStartGuide_Free50
24/27
Page 23 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
11)Click Fileand select Install Configuration.
12)The Installation Optionsdialog box appears. Click OK.
8/12/2019 QuickStartGuide_Free50
25/27
Page 24 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
13)An installation status message appears. Click No.
If you click Yes, you will see a detailed report for the configuration.
NOTE:As you can see, there are already 22 objects in the configuration. This is because IGSS comes with a
number of predefined objects for different system purposes. The predefined objects are included for free,
that is, an IGSS license will include extra 15 objects. For example, the IGSS FREE50 license includes 65
objects. Click here to read more aboutObjects in IGSS.
Calculating the number of objects in a configuration
The number of objects is calculated as follows:
One object is counted for every new object you create
One object is counted for every new template you create
One object is counted when you name the states or commands in a digital template
(yet another object is counted if the template includes more than 25 states/commands) One object is counted for every time you use the valid commands feature in a digital template
One object is counted when you define global function keys
One object is counted for each diagram where you define function keys
You can always see the number of objects you've purchased and the number of objects currently used in
the configuration. Simply choose "Help About".
http://www.7t.dk/igss/default.asp?showid=144http://www.7t.dk/igss/default.asp?showid=144http://www.7t.dk/igss/default.asp?showid=144http://www.7t.dk/igss/default.asp?showid=1448/12/2019 QuickStartGuide_Free50
26/27
Page 25 of 26
7-Technologies7-Technologies A/S * Bistruphave 3 * DK-3460 Birkerd * Denmark
Phone: +45 45 900 800 * Fax: +45 45 900 801E-mail: [email protected] Web: http://www.7t.dk
STEP 5. Running the configuration
1) Look for the IGSS Starterbar which, by default, is located at the top of your screen. It can also beplaced left, right or bottom dependent on your preference.
Click the Startbutton.
2) The startup diagram appears in the Supervisemodule. The alarm icon appears immediately when
you start up. In this case, there are no alarms. When alarms occur, the color of the alarm icon
changes to the color of the most critical alarm. Double-click the alarm icon to view the active
alarms.
Congratulations! You have created your first IGSS configuration and brought it online.
8/12/2019 QuickStartGuide_Free50
27/27
Page 26 of 26
Help and Support
7T hopes that the IGSS FREE50 license will give you a good picture of the capabilities of the IGSS SCADA
system.
We recommend that you explore theGetting Started manualand the comprehensive IGSS help system for
further details.
Should you have technical questions, limited e-mail support is available. Send an e-mail to Technical
Support [email protected] the text IGSS FREE50 in the Subjectfield.
If you have sales-related questions, do not hesitate to contact the sales manager for your region. Read the
contact information for theIGSS Sales Departmenthere.
http://www.7t.dk/igss/default.asp?showid=349http://www.7t.dk/igss/default.asp?showid=349http://www.7t.dk/igss/default.asp?showid=349mailto:[email protected]:[email protected]:[email protected]://www.7t.dk/igss/default.asp?showid=102http://www.7t.dk/igss/default.asp?showid=102http://www.7t.dk/igss/default.asp?showid=102http://www.7t.dk/igss/default.asp?showid=102mailto:[email protected]://www.7t.dk/igss/default.asp?showid=349