AC PowerFor Business-Critical Continuity™
Emerson Network Power Rack PDU SystemsProduct Selection Guide - North American Models
i
TABLE OF CONTENTS
1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.1 Safety and Agency Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION . . . . . . . . . . . . . . . . . . .2
3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS. . . . . . . . . . . . . . . . .3
3.1 Overview - Basic Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2 Basic Rack PDU Optional Cord Sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.3 Dimensional Drawings - Basic Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.0 LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS . . . . . . . . . . . . . . .27
4.1 Overview - Managed Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.2 Specifications - Liebert MPH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.3 Model Number Configuration - Liebert MPH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.4 Managed Rack PDU Optional Cord Sets and Cable Restraints . . . . . . . . . . . . . . . . . . . . . . 30
4.5 Dimensional Drawings - Managed Rack PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.0 LIEBERT MPX - ADAPTIVE RACK PDUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
5.1 Overview - Adaptive Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.2 MPX PRC (Power Rail Chassis). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) . . . . . . . . . . . . . . . . . 36
5.4 MPX BRM (Branch Receptacle Module) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.5 Adaptive Rack PDU Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.5.1 Cord Sets and Cable Restraints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375.5.2 Liebert RPC™ (RPC-1000) and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375.5.3 Part Numbers for Liebert RPC and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385.5.4 Ports on the Liebert RPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385.5.5 Liebert RPC Capabilities and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395.5.6 RPC BDM—Basic Display Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405.5.7 Temperature/Humidity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.0 LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
6.1 STEP 1 - Select an MPX PRC (Quantity x 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
6.3 STEP 3 - Select an MPX BRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6.4 STEP 4 - Select Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.5 System Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
6.6 Specifications for Liebert MPX Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
6.7 Dimensional Drawings - Adaptive Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
ii
FIGURESFigure 1 Knurr DI-STRIP 35351011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Figure 2 Knurr DI-STRIP 35351021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Figure 3 Knurr DI-STRIP 35351031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Figure 4 Knurr DI-STRIP 35351041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Figure 5 Knurr DI-STRIP 35351051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Figure 6 Knurr DI-STRIP 35351061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Figure 7 Knurr DI-STRIP 35351081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Figure 8 Knurr DI-STRIP 35352011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Figure 9 Knurr DI-STRIP 35352021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Figure 10 Knurr DI-STRIP 35352031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Figure 11 Knurr DI-STRIP 35352041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Figure 12 Knurr DI-STRIP 35352051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 13 Knurr DI-STRIP 35352061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Figure 14 Knurr DI-STRIP 35352078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Figure 15 Knurr DI-STRIP 35353011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Figure 16 Knurr DI-STRIP 35353021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Figure 17 Knurr DI-STRIP 35353031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Figure 18 Knurr DI-STRIP 35353041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Figure 19 Knurr DI-STRIP 35353051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Figure 20 Knurr DI-STRIP 35353061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Figure 21 Knurr DI-STRIP 35353078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Figure 22 Knurr DI-STRIP 35353088 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Figure 23 Liebert MPH rack mount power strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Figure 24 Liebert MPH vertical power strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Figure 25 Liebert MPX 1880 and 1035 models and components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Figure 26 MPX PRC (Power Rail Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Figure 27 Liebert RPC ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Figure 28 RPC BDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Figure 29 Temperature/humidity sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Figure 30 Liebert MPX MPXPRC-1035mm mixed modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Figure 31 Liebert MPX MPXPRC-1880mm mixed modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
TABLESTable 1 Specifications - Knurr DI-STRIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Table 2 Cord sets - Knurr DI-STRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Table 3 Specifications - Liebert MPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Table 4 Cord sets and cable restraints - Liebert MPH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Table 6 Selections for Power Entry Module MPXPEM-NHBXXV30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Table 7 Selections for Power Entry Module MPXPEM-NHBXXX30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Table 8 Selections for Power Entry Module MPXPEM-NHBXXW30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Table 9 Specifications - MPX BRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Emerson Network Power Rack PDU Systems
1
1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS
Emerson Network Power’s Rack PDU Systems is a family of products that delivers power and man-agement to connected IT equipment through a global and comprehensive offering including Basic, Managed and Adaptive Rack PDU systems.
Each PDU type offers simplified installation and easy operation. Each type is compatible with standard rack enclosures. These Emerson Rack PDUs provide easy low-cost installation, simple relocation, security and proven design and performance.
Emerson Rack PDUs can be set up with varying degrees of power-monitoring and management. When power or management requirements grow, the adaptive PDUs are scalable, enabling them to grow with the installation.
Emerson PDUs are available for the entire spectrum of power needs of every type of rack equipment.
• Knurr® DI-STRIP - Basic Rack PDU systems, provide a broad range of power distribution capac-ities and connectivity solutions in a robust package.
• Liebert MPH™ - Managed Rack PDUs with single-phase or three-phase capability for fixed power input/output with remote management support; one-piece unit with monitoring at the branch level and control at the receptacle level; available in rack-mount and zero U configurations.
• Liebert MPX™ - Adaptive Rack PDUs built with modular and scalable components that can be installed and reconfigured on-site to meet changing input and output power connectivity needs; with remote monitoring at the branch level and receptacle management and control at the recep-tacle level.
1.1 Safety and Agency Compliance
Where a conflict arises between the following documents and statements made herein, the statements in this specification will govern.
North American Units - 120V and 208V (Single-Phase and Three-Phase)• UL 60950-1 Information Technology Equipment• CAN/CSA-C22.2 No. 60950-1-03 Information Technology Equipment• FCC, Title 47, Part 15 Subpart B for Class A operation as defined by ANSI Standard C63.4• ISTA Procedure 1A and 2A• RoHS Compliant
Determining the Right Emerson PDU for Your Application
2
2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION
Each of the Rack PDU systems Emerson offers is well-suited for delivering power to sensitive, high-capacity, rack-mounted equipment. Determining which is best for a particular installation requires knowing the basic power requirements of the equipment in the rack, deciding on the acceptable or preferable level of monitoring and control and then balancing those considerations against site requirements.
The Emerson Rack PDU product line includes models to fit all types of installations: new or estab-lished; stable or rapidly changing; contracting or expanding. Each type of installation may require any or all types of Emerson Rack PDUs.
After determining your requirements, refer to the data and specifications for each product.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
3
3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS
3.1 Overview - Basic Rack PDUs
The Knurr DI-STRIP, a Basic Rack PDU system, provides a broad range of power distribution capaci-ties and connectivity solutions in a robust package.
The Knurr DI-STRIP includes an input power cord with appropriate input plug connection and hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions are also provided. Knurr DI-STRIP Rack PDUs are available in rack mount and vertical zero-U form factors.
The Knurr DI-STRIP fits most standard 600mm width network equipment rack enclosures. Product fit should be confirmed for each application.
Table 1 Specifications - Knurr DI-STRIP
PartNumber
INPUT OUTPUT
FormFactorVoltage
RatedAmps
Max Continuous
Amps kW* Phase PlugReceptacle/Socket
Configuration
035351011 120 15 12 1.4 1 NEMA 5-15P (9) NEMA 5-15RRack mountor Vertical
035351021 120 15 12 1.4 1 NEMA 5-15P (12) NEMA 5-15R Vertical
035351031 120 15 12 1.4 1 NEMA 5-15P (18) NEMA 5-15R Vertical
035351041 120 20 16 1.9 1 NEMA L5-20P (9) NEMA 5-20 T-Slot Vertical
035351051 120 20 16 1.9 1 NEMA 5-20P (12) NEMA 5-20 T-Slot Vertical
035351061 120 20 16 1.9 1 NEMA L5-20P (12) NEMA 5-20 T-Slot Vertical
035351081 120 30 24 2.8 1 NEMA L5-30P (24) NEMA 5-20 T-Slot Vertical
035352011 208-240 20 16 3.3 1 NEMA L6-20P (9) IEC-C13 sockets Vertical
035352021** 208-240 20 16 3.3 1 IEC-C20 inlet (9) IEC-C13 sockets Rack mountor Vertical
035352031 208-240 20 16 3.3 1 NEMA L6-20P (12) IEC-C13 sockets Vertical
035352041** 208-240 20 16 3.3 1 IEC-C20 inlet (12) IEC-C13 sockets Vertical
035352051 208-240 30 24 4.9 1 NEMA L6-30P (4) IEC-C19 sockets Vertical
035352061 208-240 30 24 4.9 1 NEMA L6-30P (24) IEC-C13 sockets Vertical
035352078 208-240 30 24 4.9 1 NEMA L6-30P (20) IEC-C13 + (4) IEC-C19 sockets Vertical
035353021 120/208 20 16 5.7 3 NEMA L21-20P(18) IEC-C13 +
(6) IEC-C19 sockets Vertical
035353031 120/208 20 16 5.7 3 NEMA L21-20P (27) IEC-C13 +(6) IEC-C19 sockets Vertical
035353041 120/208 20 16 5.7 3 NEMA L21-20P (27) 5-20 T-Slot Vertical
035353011 120/208 30 24 8.6 3 NEMA L21-30P (6) IEC-C19 sockets Vertical
035353051 120/208 30 24 8.6 3 NEMA L21-30P (18) IEC-C13 +(6) IEC-C19 sockets
Vertical
035353061 120/208 30 24 8.6 3 NEMA L21-30P(27) IEC-C13 +
(6) IEC-C19 sockets Vertical
035353078 208-240 60 48 17.3 3IEC60309
(3 pole, 4 wire, 250VAC, blue)
(42) IEC-C13 +(6) IEC-C19 sockets Vertical
035353088 208-240 42 34 24.4 3(2) IEC60309
(3 pole, 4 wire,250VAC, blue)
(42) IEC-C13 +(6) IEC-C19 sockets Vertical
All input cords are 10 ft. (3m) in length.* Formulas used to calculate the kW:
For single-phase: input voltage x max continuous amps = wattsFor three-phase: input voltage x max continuous amps x 1.73 = watts
** Knurr DI-STRIP output expansion modules require the use of a cord set for input power.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
4
3.2 Basic Rack PDU Optional Cord Sets
Output Cord Sets
Output cord sets are available to support conversion of Rack PDU power output receptacles to alter-native power output connections and to support Rack PDU output expansion capabilities.
Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs.
Knurr DI-STRIP output expansion modules are powered via an IEC-C20 input connection. These systems provide output expansion capabilities when connected to a receptacle on a separate Rack PDU. The output cord set for these systems includes an IEC-C19 receptacle to connect to the IEC-C20 plug on the output expansion Knurr DI-STRIP, a 3 ft. (1m) power cord and plug to connect to the Rack PDU receptacle providing power. Available plugs include: IEC-C20 to connect to an IEC-C19 Rack PDU receptacle.
Input Cord Sets
Input cord sets are available to support conversion of Rack PDU power input connections to alternative power input connections. Conversion of power input can be provided on Rack PDUs with L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug.
Table 2 Cord sets - Knurr DI-STRIP
Cord Sets
Output Cord Sets - Power Output Conversion
539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m)
539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m)
539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m)
539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m)
Output Cord Sets - Power Output Expansion
539031G7 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 3 ft. (1m)
539031G8 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 10 ft. (3m)
539031G3 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 3 ft. (1m)
539031G4 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 10 ft. (3m)
Input Cord Sets - Power Input Conversion
539031G12 Input Cord Set - Power Input Conversion - L5-20R to 5-20P, 1 ft. (0.3m)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
5
3.3 Dimensional Drawings - Basic Rack PDUs
Figure 1 Knurr DI-STRIP 35351011
03.5
35.1
01.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
12.2
" (31
1mm
)2.
9"(7
3mm
)2.
5"(6
3mm
)
FRO
NT
VIE
W
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
3535
1011
Rev
. 3
Inpu
tC
ord
Inpu
tP
lug
Pha
seR
ated
Am
psVo
ltage
(VA
C)
5-15
P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
5-15
P12
015
112
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
psO
UTP
UT
PO
WE
R
15-
15R
(9)
120
121
12
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
17
.6" (
447m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 2.
5 lb
. (1.
1kg)
3.
Shi
ppin
g di
men
sion
s:
18
.9" (
480m
m) L
x 2
.8" (
71m
m) W
x 3
.3" (
84m
m) D
4.
Shi
ppin
g w
eigh
t: 2.
8 lb
. (1.
3kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
17.6
" (44
7mm
)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
6
Figure 2 Knurr DI-STRIP 35351021
03.5
35.1
02.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
19.6
" (49
7mm
)FR
ON
T V
IEW
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
12.2
" (31
1mm
)4.
8"(1
23m
m)
2.5"
(63m
m) 35
3510
21R
ev. 3
Inpu
tC
ord
Pha
seR
ated
Am
ps
5-15
P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
5-15
P12
015
112
OU
TPU
T P
OW
ER
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
15-
15R
(9)
120
121
12
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
19
.6" (
497m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 2.
7 lb
. (1.
2kg)
3.
Shi
ppin
g di
men
sion
s:
22
.2" (
565m
m) L
x 2
.8" (
70m
m) W
x 3
.3" (
85m
m) D
4.
Shi
ppin
g w
eigh
t: 3.
1 lb
. (1.
4kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
Inpu
tP
lug
Volta
ge(V
AC
)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
7
Figure 3 Knurr DI-STRIP 35351031
03.5
35.1
03.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
27.4
" (69
7mm
)FR
ON
T V
IEW
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
Inpu
tC
ord
Pha
seR
ated
Am
ps
5-15
P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
5-15
P12
015
112
OU
TPU
T P
OW
ER
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
15-
15R
(18)
120
121
1235
3510
31R
ev. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
27
.4" (
697m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 3.
3 lb
. (1.
5kg)
3.
Shi
ppin
g di
men
sion
s:
42
" (10
65m
m) L
x 2
.4" (
60m
m) W
x 3
" (75
mm
) D4.
S
hipp
ing
wei
ght:
3.8
lb. (
1.72
kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
Inpu
tP
lug
Volta
ge(V
AC
)
12.2
" (31
1mm
)12
.7" (
323m
m)
2.5"
(63m
m)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
8
Figure 4 Knurr DI-STRIP 35351041
03.5
35.1
04.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
17.6
" (44
7mm
)FR
ON
T V
IEW
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
Inpu
tC
ord
Pha
seR
ated
Am
ps
L5-2
0P(2
pol
e, 3
wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
L5-2
0P12
020
116
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
psO
UTP
UT
PO
WE
R
15-
20R
(9)
120
161
1635
3510
41R
ev. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
17
.6" (
447m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 3
lb. (
1.35
kg)
3.
Shi
ppin
g di
men
sion
s:
26
.8" (
680m
m) L
x 2
.4" (
60m
m) W
x 3
.9" (
100m
m) D
4.
Shi
ppin
g w
eigh
t: 3.
4 lb
. (1.
54kg
)5.
A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal
an
d lo
cal e
lect
ric c
odes
.6.
M
ount
ing
prov
isio
ns p
rovi
ded.
Inpu
tP
lug
Volta
ge(V
AC
)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
9
Figure 5 Knurr DI-STRIP 35351051
03.5
35.1
05.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
19.6
" (49
7mm
)FR
ON
T V
IEW
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
Inpu
tC
ord
Pha
seR
ated
Am
ps
5-20
P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
5-20
P12
020
116
OU
TPU
T P
OW
ER
12.2
" (31
1mm
)4.
8"(1
23m
m)
2.5"
(63m
m)
Inpu
tP
lug
Volta
ge(V
AC
)
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
15-
20R
(9)
120
161
1635
3510
51R
ev. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
19
.6" (
497m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 3.
5 lb
. (1.
57kg
)3.
S
hipp
ing
dim
ensi
ons:
26.8
" (68
0mm
) L x
2.4
" (60
mm
) W x
3.9
" (10
0mm
) D4.
S
hipp
ing
wei
ght:
3.9
lb. (
1.76
kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
10
Figure 6 Knurr DI-STRIP 35351061
03.5
35.1
06.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
19.6
" (49
7mm
)FR
ON
T V
IEW
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
Inpu
tC
ord
Pha
seR
ated
Am
ps
L5-2
0P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
L5-2
0P12
020
116
OU
TPU
T P
OW
ER
12.2
" (31
1mm
)4.
8"(1
23m
m)
2.5"
(63m
m)
Inpu
tP
lug
Volta
ge(V
AC
)
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
15-
20R
(12)
120
161
1635
3510
61R
ev. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
19
.6" (
497m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 3.
2 lb
. (1.
47kg
)3.
S
hipp
ing
dim
ensi
ons:
24.6
" (62
5mm
) L x
2.4
" (60
mm
) W x
3.9
" (10
0mm
) D4.
S
hipp
ing
wei
ght:
3.5
lb. (
1.6k
g)5.
A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal
an
d lo
cal e
lect
ric c
odes
.6.
M
ount
ing
prov
isio
ns p
rovi
ded.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
11
Figure 7 Knurr DI-STRIP 35351081
03.5
35.1
08.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
24.5
" (62
2mm
)16
.6" (
422m
m)
2.1"
(53m
m)
Bra
nch
Rec
epta
cle
Type
(Qty
)R
ecep
tacl
e Ty
peP
hase
Per
Rec
epta
cle
Per
Bra
nch
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
15-
20R
(12)
120
161
20
25-
20R
(12)
120
161
2035
3510
81R
ev. 4
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
43
.2" (
447m
m) L
x 1
.7" (
44m
m) W
x 3
.3" (
85m
m) D
2.
Uni
t wei
ght:
7.51
lb. (
3.4k
g)3.
S
hipp
ing
dim
ensi
ons:
44.9
" (11
40m
m) L
x 2
.8" (
70m
m) W
x 6
.3" (
160m
m) D
4.
Shi
ppin
g w
eigh
t: 8.
4 lb
. (3.
8kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
43.2
" (10
97m
m)
FRO
NT
VIE
W
20A
bran
ch c
ircui
t bre
aker
sB
ranc
h 2
Bra
nch
1
20A
bran
chci
rcui
t bre
aker
s
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
1.8"
(46m
m)
3.3"
(85m
m)
Inpu
tC
ord
Pha
seR
ated
Am
ps
L5-3
0P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
L5-3
0P12
030
124
OU
TPU
T P
OW
ER
Inpu
tP
lug
Volta
ge(V
AC
)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
12
Figure 8 Knurr DI-STRIP 35352011
03.5
35.2
01.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
17.6
" (44
7mm
)FR
ON
T V
IEW
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
Inpu
tC
ord
Pha
seR
ated
Am
ps
L6-2
0P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
L6-2
0P20
8-24
020
116
OU
TPU
T P
OW
ER
Inpu
tP
lug
Volta
ge(V
AC
)
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
1IE
C-C
13 (9
)20
8-24
012
116
3535
2011
Rev
. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
17
.6" (
447m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 3.
2 lb
. (1.
4kg)
3.
Shi
ppin
g di
men
sion
s:
24
.6" (
625m
m) L
x 2
.4" (
60m
m) W
x 3
.9" (
100m
m) D
4.
Shi
ppin
g w
eigh
t: 3.
4 lb
. (1.
5kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
13
Figure 9 Knurr DI-STRIP 35352021
03.5
35.2
02.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
17.6
" (44
7mm
)
2.5"
(63m
m)
12.2
" (31
1mm
)2.
9" (7
3mm
)
IEC
-C20
inle
tFR
ON
T V
IEW
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
Inpu
tC
ord
Inpu
tP
hase
Rat
edA
mps
Volta
ge(V
AC
)M
ax. C
ont.
Am
ps
INP
UT
PO
WE
R
10 ft
. (3
m)
208-
240
201
16
OU
TPU
T P
OW
ER
* R
equi
res
a co
rdse
t
IEC
-C20
Inle
t *
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
1IE
C-C
13 (9
)20
8-24
012
116
3535
2021
Rev
. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
17
.6" (
447m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 1.
5 lb
. (0.
7kg)
3.
Shi
ppin
g di
men
sion
s:
19
" (48
3mm
) L x
3" (
75m
m) W
x 2
.4" (
60m
m) D
4.
Shi
ppin
g w
eigh
t: 1.
7 lb
. (0.
8kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
14
Figure 10 Knurr DI-STRIP 35352031
03.5
35.2
03.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
19.6
" (49
7mm
)
2.5"
(63m
m)
12.2
" (31
1mm
)4.
8" (1
23m
m)
FRO
NT
VIE
W
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
Inpu
tC
ord
Pha
seR
ated
Am
ps
L6-2
0P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3
m)
L6-2
0P20
8-24
020
116
OU
TPU
T P
OW
ER
Inpu
tP
lug
Volta
ge(V
AC
)
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
1IE
C-C1
3 (1
2)20
8-24
012
116
3535
2031
Rev
. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
19
.6" (
497m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 3.
4 lb
. (1.
5kg)
3.
Shi
ppin
g di
men
sion
s:
26
.8" (
680m
m) L
x 2
.4" (
60m
m) W
x 3
.9" (
100m
m) D
4.
Shi
ppin
g w
eigh
t: 3.
7 lb
. (1.
68kg
)5.
A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal
an
d lo
cal e
lect
ric c
odes
.6.
M
ount
ing
prov
isio
ns p
rovi
ded.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
15
Figure 11 Knurr DI-STRIP 35352041
03.5
35.2
04.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
Inpu
tP
lug
Volta
ge(V
AC
)
Ban
kR
ecep
tacl
eTy
pe (Q
ty)
Rec
epta
cle
Type
Pha
seP
er R
ecep
tacl
eP
er B
ank
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
1IE
C-C1
3 (1
2)20
8-24
012
116
3535
2041
Rev
. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
19
.6" (
497m
m) L
x 1
.7" (
44m
m) W
x 2
" (50
mm
) D2.
U
nit w
eigh
t: 1.
8 lb
. (0.
8kg)
3.
Shi
ppin
g di
men
sion
s:
22
.6" (
575m
m) L
x 2
.4" (
60m
m) W
x 3
" (75
mm
) D4.
S
hipp
ing
wei
ght:
2.1
lb. (
0.9k
g)5.
A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal
an
d lo
cal e
lect
ric c
odes
.6.
M
ount
ing
prov
isio
ns p
rovi
ded.
19.6
" (49
7mm
)
12.2
" (31
1mm
)2.
5" (6
3mm
)4.
8" (1
23m
m)
FRO
NT
VIE
WIE
C-C
20 IN
LET
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
2"(5
0mm
)
Inpu
tC
ord
Pha
seR
ated
Am
psM
ax. C
ont.
Am
ps
INP
UT
PO
WE
R
10 ft
. (3
m)
IEC
-C20
inle
t *20
8-24
020
116
OU
TPU
T P
OW
ER
* R
equi
res
a co
rdse
t
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
16
Figure 12 Knurr DI-STRIP 35352051
03.5
35.2
05.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
17.6
" (44
7mm
)FR
ON
T V
IEW
20A
bran
ch c
ircui
t bre
aker
Bra
nch
2B
ranc
h 1
20A
bran
chci
rcui
t bre
aker
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
1.8"
(46m
m)
3.3"
(85m
m)
3535
2051
Rev
. 3
Inpu
tC
ord
Inpu
tP
lug
Pha
seR
ated
Am
psVo
ltage
Volta
ge (V
AC
)
L6-3
0P(2
-pol
e, 3
-wire
)
Max
. Con
t.A
mps
INP
UT
PO
WE
R
10 ft
. (3m
)L6
-30P
208-
240
301
24
Rec
epta
cle
Type
(Qua
ntity
)
Per
Rec
epta
cle
Type
Per
Rec
epta
cle
Per
Bra
nch
Pha
seB
ranc
h
Max
. Con
tinuo
us A
mps
OU
TPU
T P
OW
ER
IEC
-C19
(2)
208-
240
208-
240
11 1
216 16
2020
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32
°F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge T
empe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
Uni
t Dim
ensi
ons:
17.
6" (4
47m
m) L
x 1
.7" (
44m
m) W
x 2
.0" (
50m
m) D
2. U
nit W
eigh
t: 4.
8lb.
(2.2
kg)
3. S
hipp
ing
Dim
ensi
ons:
29.
0" (7
40m
m) L
x 6
.3" (
160m
m) W
x 2
.7" (
70m
m) D
4. S
hipp
ing
Wei
ght:
5.5l
bs (2
.5kg
)5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l and
loca
l
ele
ctric
cod
es.
6. M
ount
ing
prov
isio
ns p
rovi
ded.
IEC
-C19
(2)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
17
Figure 13 Knurr DI-STRIP 35352061
0353
5206
1R
ev. 3
1220
1220
03.5
35.2
06.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
AG
EN
CY:
CS
A Te
sted
to U
L 60
950-
1R
oHS
Com
plia
nt (R
educ
tion
of H
azar
dous
Sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F-1
31°
F (0
° C
-55°
C )
non-
cond
ensi
ng,
non
-cor
rosi
ve, 5
% -
95%
RH
Sto
rage
Tem
pera
ture
: -4°
F-1
40°
F (-
20°
C -
60°
C )
NO
TES
:1.
U
nit D
imen
sion
s:
43
.2" (
1097
mm
) L x
1.7
" (44
mm
) W x
3.3
" (85
mm
) D2.
U
nit W
eigh
t: 6.
8lbs
(3.1
kg)
3.
Shi
ppin
g D
imen
sion
s:
44
.9" (
1140
mm
) L x
2.8
" (70
mm
) W x
6.3
" (16
0mm
) D4.
S
hipp
ing
Wei
ght:
7.7l
bs (3
.5kg
)5.
A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal
an
d lo
cal e
lect
ric c
odes
.6.
M
ount
ing
prov
isio
ns p
rovi
ded.
Inpu
t Cor
d In
put P
lug
Pha
se
Volta
ge (V
AC
)R
ated
Am
psM
ax C
ont.
Am
ps
Max
Con
t. A
mps
L6-3
0P10
ft/3
.0m
1 2
1 1 1
208-
240
208-
240
208-
240
INP
UT
PO
WE
R
OU
TPU
T P
OW
ER
3024
IEC
-C13
(12)
IEC
-C13
(12)
Bra
nch
Volta
ge (V
AC
)
Per
Rec
epta
cle
Type
Per
Rec
epta
cle
Per
Bra
nch
Rec
epta
cle
Type
(Qua
ntity
)P
hase
L6-3
0P(2
Pol
e, 3
Wire
)
RE
AR
VIE
W
SID
E V
IEW
FRO
NT
VIE
W
BR
AN
CH
1B
RA
NC
H 2
20A
Bra
nch
Circ
uit B
reak
er
20A
Bra
nch
Circ
uit B
reak
er
1.8"
(46m
m)
16.6
" (42
2mm
)24
.5" (
622m
m)
2.1
(53
mm
)
3.3"
(85m
m)
1.7"
(44m
m)
43.2
" (10
97m
m)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
18
Figure 14 Knurr DI-STRIP 35352078
20A
bran
ch c
ircui
t bre
aker
20A
bran
ch c
ircui
t bre
aker
21.3
" (54
0mm
)FR
ON
T V
IEW
TOP
VIE
W
BO
TTO
M V
IEW
6.7"
(170
mm
)
1.9"
(47m
m)
Inpu
t Cor
dP
hase
Rat
ed A
mps
Max
. Con
t. A
mps
INP
UT
PO
WE
R
10 ft
. (3m
)L6
-30P
208-
240
301
24
OU
TPU
T P
OW
ER
Inpu
t Plu
gVo
ltage
(VA
C)
Bra
nch
Rec
epta
cle
Type
(Qty
)R
ecep
tacl
e Ty
peP
hase
Per
Rec
epta
cle
Per
Bra
nch
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
1IE
C-C1
3 (1
0) /
IEC-
C19
(2)
208-
240
/ 208
-240
208-
240
/ 208
-240
12 /
161
/ 120
2IE
C-C1
3 (1
0) /
IEC-
C19
(2)
12 /
161
/ 120
3535
2078
Rev
. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
21
.3" (
540m
m) L
x 6
.7" (
170m
m) W
x 1
.9" (
47m
m) D
2.
Uni
t wei
ght:
15 lb
. (6.
8kg)
3.
Shi
ppin
g di
men
sion
s:
22
.4" (
570m
m) L
x 1
1.6"
(295
mm
) W x
6.3
" (16
0mm
) D4.
S
hipp
ing
wei
ght:
18.3
lb. (
8.3k
g)5.
A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal
an
d lo
cal e
lect
ric c
odes
.6.
M
ount
ing
prov
isio
ns p
rovi
ded.
L6-3
0P(2
-pol
e, 3
-wire
)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
19
Figure 15 Knurr DI-STRIP 35353011
0353
5301
1R
ev. 3
1620
1620 20
03.5
35.3
01.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BA
SIC
DI S
TRIP
20A
Bra
nch
Circ
uit B
reak
er20
A B
ranc
hC
ircui
t Bre
aker
20A
Bra
nch
Circ
uit B
reak
er
RE
AR
VIE
W
SID
E V
IEW
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32
°F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
ve,
Sto
rage
Tem
pera
ture
: -4°
F to
140
°F (-
20°C
to 6
0°C
)
NO
TES
:1.
U
nit d
imen
sion
s:
27.4
" (69
7mm
) L x
1.7
" (44
mm
) W x
3.3
" (85
mm
) D2.
U
nit w
eigh
t:
8 lb
. (3.
6kg)
3.
Shi
ppin
g di
men
sion
s:
64.6
" (16
40m
m) L
x 2
.8" (
70m
m) W
x 6
.3" (
160m
m) D
4.
Shi
ppin
g w
eigh
t: 9.
4 lb
. (4.
3kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
FRO
NT
VIE
W
1.7"
(44m
m)
3.3"
(85m
m)
1.8"
[46m
m
L21-
30P
(4 p
ole,
5 w
ire)
Inpu
t Cor
dIn
put P
lug
Volta
ge (V
AC
)
Volta
ge (V
AC
)
10 ft
. (3m
)
OU
TPU
T P
OW
ER
INP
UT
PO
WE
R L21-
30P
3
Pha
se
Pha
se
Rat
ed A
mps
3024
120/
208
Max
Con
t. A
mps
Max
Con
t. A
mps
IEC
-C19
(2)
IEC
-C19
(2)
IEC
-C19
(2)
208-
240
208-
240
208-
240
Bra
nch
Rec
epta
cle
Type
(Qua
ntity
)
Per
Rec
epta
cle
Type
Per
Rec
epta
cle
Per
Bra
nch
16
1 11 1 1
1
0.9"
(23m
m)
24.5
" (62
2mm
)
27.4
" (69
7mm
)
Bra
nch
3B
ranc
h 2
Bra
nch
1
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
20
Figure 16 Knurr DI-STRIP 35353021
03.5
35.3
02.1
00/0
0 00
0000
ww
w.k
nuer
r.co
m
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BASI
CD
I ST
RIP
24.
5" (6
22m
m)
Bra
nch
1B
ranc
h 3
Bra
nch
2
FRO
NT
VIE
W
RE
AR
VIE
W
SID
E V
IEW
L21-
20P
(4 p
ole,
5 w
ire)
39.3
" (99
7mm
)
1.7"
(44m
m)
2.0"
(50m
m)
12.7
" (32
2mm
)2.
1"(5
3mm
)
AG
EN
CY:
CS
A Te
sted
to U
L 60
950-
1R
oHS
Com
plia
nt (R
educ
tion
of H
azar
dous
Sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F-13
1°F
(0°C
to 5
5°C
) no
n-co
nden
sing
, non
-cor
rosi
ve,
5% -
95%
RH
Sto
rage
Tem
pera
ture
: -4°
F to
140
°F (-
20°C
to 6
0°C
)
NO
TES
:1.
Uni
t Dim
ensi
ons:
39.
3" (9
97m
m) L
x 1
.7" (
44m
m) W
x 2
.0" (
50m
m) D
2. U
nit W
eigh
t: 5.
8 lb
. (2.
63kg
)3.
Shi
ppin
g D
imen
sion
s: 4
0.4"
(102
7mm
) L x
2.3
" (60
mm
) W x
3.9
" (10
0mm
) D4.
Shi
ppin
g W
eigh
t: 6.
2 lb
. (2.
8kg)
5. A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal a
nd lo
cal e
lect
ric c
odes
.6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
0353
5302
1R
ev. 3
Inpu
t Cor
dIn
put P
lug
Volta
ge (V
AC
)
Volta
ge (V
AC
)
Pha
se
Pha
se
10 ft
/3.0
mL2
1-20
P3
321
120/
208
20
Rat
ed A
mps
Max
Con
t. A
mps
Max
Con
t. A
mps
Bra
nch
Rec
epta
cle
Type
(Qua
ntity
)
INP
UT
PO
WE
R
OU
TPU
T P
OW
ER
IEC
-C13
(6)/I
EC
-C19
(2)
IEC
-C13
(6)/I
EC
-C19
(2)
IEC
-C13
(6)/I
EC
-C19
(2)
Per
Rec
epta
cle
Type
208-
240/
208-
240
208-
240/
208-
240
161616
16
12 /
16
12 /
16
12 /
16
Per
Bra
nch
Per
Rec
epta
cle
1 / 1
1 / 1
1 / 1
208-
240/
208-
240
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
21
Figure 17 Knurr DI-STRIP 35353031
03.5
35.3
03.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BASI
CD
I ST
RIP
Bra
nch
1
Bra
nch
3B
ranc
h 2
FRO
NT
VIE
W
RE
AR
VIE
W
SID
E V
IEW
L21-
20P
(4 P
ole,
5 W
ire)
AG
EN
CY:
CS
A Te
sted
to U
L 60
950-
1R
oHS
Com
plia
nt (R
educ
tion
of H
azar
dous
Sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C )
non-
cond
ensi
ng, n
on-c
orro
sive
,5%
- 95
% R
HS
tora
ge T
empe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C )
NO
TES
:1.
Uni
t Dim
ensi
ons:
51.
1" (1
297m
m) L
x 1
.7" (
44m
m) W
x 2
.0" (
50m
m) D
2. U
nit W
eigh
t: 7.
0 lb
. (3.
2kg)
3. S
hipp
ing
Dim
ensi
ons:
72.
0" (1
830m
m) L
x 2
.4" (
60m
m) W
x 3
.5" (
90m
m) D
4. S
hipp
ing
Wei
ght:
7.5
lb. (
3.4k
g)5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l and
loca
l ele
ctric
cod
es.
6. M
ount
ing
prov
isio
ns p
rovi
ded.
0353
5303
1R
ev. 3
Inpu
t Cor
dIn
put P
lug
Volta
ge (V
AC
)
Volta
ge (V
AC
)
Pha
se
Pha
se
10 ft
/3.0
mL2
1-20
P3
321
120/
208
20
Rat
ed A
mps
Max
Con
t. A
mps
Max
Con
t. A
mps
Ban
kR
ecep
tacl
e Ty
pe(Q
uant
ity)
INP
UT
PO
WE
R
OU
TPU
T P
OW
ER
IEC
-C13
(9) /
IEC
-C19
(2)
IEC
-C13
(9) /
IEC
-C19
(2)
IEC
-C13
(9) /
IEC
-C19
(2)
Per
Rec
epta
cle
Type
208
-240
/208
-240
208
-240
/208
-240
208
-240
/208
-240
161616
16
12 /
16
12 /
16
12 /
16
Per
Ban
kP
er R
ecep
tacl
e
1 / 1
1 / 1
1 / 1
51.1
" (12
97m
m)
36.8
" (93
4mm
)
1.7"
(44m
m)
2.5
(63m
m)
2.0"
(50m
m)
11.9
" (30
1mm
)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
22
Figure 18 Knurr DI-STRIP 35353041
39.3
" [99
7mm
]
24.5
" [62
2mm
]
03.5
35.3
04.1
00/0
0 00
0000
ww
w.k
nuer
r.co
m
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BASI
CD
I ST
RIP
Bra
nch
1
Bra
nch
3
Bra
nch
2
FRO
NT
VIE
W
RE
AR
VIE
W
SID
E V
IEW
L21-
20P
(4 P
ole,
5 W
ire)
AG
EN
CY:
CS
A Te
sted
to U
L 60
950-
1R
oHS
Com
plia
nt (R
educ
tion
of H
azar
dous
Sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C )
non-
cond
ensi
ng, n
on-c
orro
sive
,5%
- 95
% R
HS
tora
ge T
empe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C )
NO
TES
:1.
Uni
t Dim
ensi
ons:
39.
3" (9
97m
m) L
x 1
.7" (
44m
m) W
x 2
.0" (
50m
m) D
2. U
nit W
eigh
t: 5.
7lb.
(2.6
kg)
3. S
hipp
ing
Dim
ensi
ons:
40.
4" (1
027m
m) L
x 2
.3" (
60m
m) W
x 4
.0" (
100m
m) D
4. S
hipp
ing
Wei
ght:
6.3l
b. (2
.85k
g)5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l and
loca
l ele
ctric
cod
es.
6. M
ount
ing
prov
isio
ns p
rovi
ded.
0353
5304
1R
ev. 3
INP
UT
PO
WE
R
1.7"
(44m
m)
2.0"
(50m
m)
2.5
(63m
m)
39.3
" [99
7mm
24.5
" (62
2mm
)12
.3" (
312m
m)
Inpu
t Cor
dIn
put P
lug
Volta
ge (V
AC
)
Volta
ge (V
AC
)
Pha
se
Pha
se
10 ft
/3.0
mL2
1-20
P3
321
120/
208
20
Rat
ed A
mps
Max
Con
t. A
mps
Max
Con
t. A
mps
Ban
kR
ecep
tacl
e Ty
pe(Q
uant
ity)
OU
TPU
T P
OW
ER 5/20
R (9
)5/
20R
(9)
5/20
R (9
)
Per
Rec
epta
cle
Type
120
120
120
161616
16
16 16 16
Per
Ban
kP
er R
ecep
tacl
e
1 1 1
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
23
Figure 19 Knurr DI-STRIP 35353051
03.5
35.3
05.1
00/0
0 00
0000
ww
w.k
nuer
r.com
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BAS
ICD
I STR
IP
20A
bran
chci
rcui
t bre
aker
20A
bran
chci
rcui
t bre
aker
Bra
nch
3B
ranc
h 2
Bra
nch
1
20A
bran
chci
rcui
t bre
aker
51.1
" (1
297m
m)
25.7
" (6
52m
m)
24.5
" (6
22m
m)
0.9"
(23m
m)
FRO
NT
VIE
W
RE
AR
VIE
W
SID
E V
IEW
1.7"
(44m
m)
1.8"
(46m
m)
3.3"
(85m
m)
Inpu
t Cor
dIn
put P
lug
Pha
seR
ated
Am
psVo
ltage
(VA
C)
L21-
30P
(4-p
ole,
5-w
ire)
Max
. Con
t. A
mps
INP
UT
PO
WE
R
10 ft
. (3m
)L2
1-30
P12
0 / 2
0830
324
OU
TPU
T P
OW
ER
Bra
nch
Rec
epta
cle
Type
(Qty
)R
ecep
tacl
e Ty
peP
hase
Per
Rec
epta
cle
Per
Bra
nch
Volta
ge (V
AC
)M
ax. C
ont.
Am
ps
1IE
C-C1
3 (6
) / IE
C-C1
9 (2
)20
8-24
0/20
8-24
012
/ 16
1 / 1
20
2IE
C-C1
3 (6
) / IE
C-C1
9 (2
)20
8-24
0/20
8-24
012
/ 16
1 / 1
2035
3530
51R
ev. 3
AG
EN
CY:
CS
A te
sted
to U
L 60
950-
1R
oHS
com
plia
nt (r
educ
tion
of h
azar
dous
sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C),
5% -
95%
RH
no
n-co
nden
sing
, non
-cor
rosi
veS
tora
ge te
mpe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C)
NO
TES
:1.
U
nit d
imen
sion
s:
51
.1" (
1297
mm
) L x
1.7
" (44
mm
) W x
3.3
" (85
mm
) D2.
U
nit w
eigh
t: 10
.1 lb
. (4.
6kg)
3.
Shi
ppin
g di
men
sion
s:
64
.6" (
1640
mm
) L x
2.8
" (70
mm
) W x
6.3
" (16
0mm
) D4.
S
hipp
ing
wei
ght:
11.6
lb. (
5.25
kg)
5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l
and
loca
l ele
ctric
cod
es.
6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.3
IEC-
C13
(6) /
IEC-
C19
(2)
208-
240/
208-
240
12 /
161
/ 120
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
24
Figure 20 Knurr DI-STRIP 35353061
1 2 320 2020
03.5
35.3
06.1
00/0
0 00
0000
ww
w.k
nuer
r.co
m
120
VAC
, 60H
zIn
put:
max
. 15A
Out
lets
: max
. 15A
NA
BASI
CD
I ST
RIP
62.9
" (15
97m
m)
Fron
t Vie
w
1.7"
(44m
m)
3.3"
(8
5mm
)
Rea
r Vie
w
0353
5306
1R
ev. 3
Bra
nch
1B
ranc
h 2
Bra
nch
3
20A
Bra
nch
Circ
uit B
reak
er20
A B
ranc
hC
ircui
t Bre
aker
20A
Bra
nch
Circ
uit B
reak
er
1.8"
(46m
m)
L21-
30P
(4 P
ole,
5 W
ire)
13.0
" (33
0mm
)49
.0" (
1245
mm
)0.
9"(2
2mm
)
AG
EN
CY:
CS
A Te
sted
to U
L 60
950-
1R
oHS
Com
plia
nt (R
educ
tion
of H
azar
dous
Sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F to
131
°F (0
°C to
55°
C )
non-
cond
ensi
ng, n
on-c
orro
sive
,5%
- 95
% R
HS
tora
ge T
empe
ratu
re: -
4°F
to 1
40°F
(-20
°C to
60°
C )
NO
TES
:1.
Uni
t Dim
ensi
ons:
62.
9" (9
97m
m) L
x 1
.7" (
44m
m) W
x 3
.3" (
85m
m) D
2. U
nit W
eigh
t: 11
.0lb
. (5.
0kg)
3. S
hipp
ing
Dim
ensi
ons:
72.
4" (1
840m
m) L
x 2
.8" (
70m
m) W
x 6
.3" (
160m
m) D
4. S
hipp
ing
Wei
ght:
12.7
lb. (
5.75
kg)
5. A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal a
nd lo
cal e
lect
ric c
odes
.6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
Inpu
t Cor
dIn
put P
lug
Volta
ge (V
AC
)
INP
UT
PO
WE
R
OU
TPU
T P
OW
ER
10ft/
3.0m
L21-
30P
312
0/20
824
Pha
se
Pha
se
Rat
ed A
mps
Max
Con
t. A
mps
Max
Con
t. A
mps
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
12 /
1612
/ 16
12 /
16
IEC
-C13
(9) /
IEC
-C19
(2)
IEC
-C13
(9) /
IEC
-C19
(2)
IEC
-C13
(9) /
IEC
-C19
(2)
1 / 1
1 / 1
1 / 1
30
Volta
ge (V
AC
)
Bra
nch
Rec
epta
cle
Type
(Qua
ntity
)
Per
Rec
epta
cle
Type
Per
Rec
epta
cle
Per
Bra
nch
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
25
Figure 21 Knurr DI-STRIP 35353078
0353
5307
8R
ev. 5
20A
Bra
nch
Circ
uit B
reak
er20
A B
ranc
hC
ircui
t Bre
aker
20A
Bra
nch
Circ
uit B
reak
er20
A B
ranc
hC
ircui
t Bre
aker
20A
Bra
nch
Circ
uit B
reak
er20
A B
ranc
hC
ircui
t Bre
aker
63.0
" (16
00m
m)
FRO
NT
VIE
W
6.7"
(170
mm
)
RE
AR
VIE
W
SID
E V
IEW
IEC
603
09(3
PO
LE, 4
WIR
E, 2
50VA
C, B
LUE
)
1.9"
(47m
m)
AG
EN
CY:
UL
6095
0-1,
cU
LR
oHS
Com
plia
nt (R
educ
tion
of H
azar
dous
Sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F-13
1°F
(0°C
to 5
5°C
) non
-con
dens
ing,
non
-cor
rosi
ve,
5% -
95%
RH
Sto
rage
Tem
pera
ture
: -4°
F to
140
°F (-
20°C
to 6
0°C
)
NO
TES
:1.
Uni
t dim
ensi
ons:
63.
0" (1
600m
m) L
x 6
.7" (
170m
m) W
x 1
.9" (
47m
m) D
2. U
nit W
eigh
t: 32
.8lb
s (1
4.9k
g)3.
Shi
ppin
g D
imen
sion
s: 7
4.0"
(188
0mm
) L x
16.
3" (4
15m
m) W
x 6
.3" (
160m
m) D
4. S
hipp
ing
Wei
ght:
38.4
lb. (
17.4
kg)
5. A
ll w
iring
is to
be
in c
ompl
ianc
e w
ith n
atio
nal a
nd lo
cal
elec
tric
code
s.6.
Mou
ntin
g pr
ovis
ions
pro
vide
d.
12 /
16
OU
TPU
T P
OW
ER
INP
UT
PO
WE
RIn
put C
ord
Inpu
t Plu
g Vo
ltage
(VA
C)
Volta
ge (V
AC
)
10ft/
3.0m
IEC
603
093
Pha
se
Pha
se
Rat
ed A
mps
208-
240
Max
. Con
t. A
mps
Max
. Con
t. A
mps
4860
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
Bra
nch
Rec
epta
cle
Type
(Qua
ntity
)
1 / 1
1 / 1
1 / 1
1 / 1
1 / 1
1 / 1
1 2 3 4 5 6
Per
Rec
epta
cle
Type
Per
Rec
epta
cle
Per
Bra
nch
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
20
12 /
1620
12 /
1620
12 /
1620
12 /
1620
12 /
1620
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
26
Figure 22 Knurr DI-STRIP 35353088
0353
5308
8R
ev. 5
20A
Bra
nch
Circ
uit B
reak
er20
A B
ranc
hC
ircui
t Bre
aker
20A
Bra
nch
Circ
uit B
reak
er20
A B
ranc
hC
ircui
t Bre
aker
20A
Bra
nch
Circ
uit B
reak
er20
A B
ranc
hC
ircui
t Bre
aker
63" (
1600
mm
)FR
ON
T V
IEW
6.7"
(170
mm
)
RE
AR
VIE
W
SID
E V
IEW
IEC
603
09(3
PO
LE, 4
WIR
E, 2
50VA
C, B
LUE
)
1.9"
(47m
m)
AG
EN
CY:
UL
6095
0-1,
cU
LR
oHS
Com
plia
nt (R
educ
tion
of H
azar
dous
Sub
stan
ces)
EN
VIR
ON
ME
NTA
L:O
pera
ting:
32°
F-13
1°F
(0°C
to 5
5°C
) non
-con
dens
ing,
non
-cor
rosi
ve,
5% -
95%
RH
Sto
rage
Tem
pera
ture
: -4°
F to
140
°F (-
20°C
to 6
0°C
)
NO
TES
:1.
Uni
t dim
ensi
ons:
63.
0" (1
600m
m) L
x 6
.7" (
170m
m) W
x 1
.9" (
47m
m) D
2. U
nit W
eigh
t: 44
.5lb
. (20
.2kg
)3.
Shi
ppin
g D
imen
sion
s: 7
4.0"
(188
0mm
) L x
16.
3" (4
15m
m) W
x 6
.3" (
160m
m) D
4. S
hipp
ing
Wei
ght:
50lb
. (22
.7kg
)5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l and
loca
l ele
ctric
cod
es.
6. M
ount
ing
prov
isio
ns p
rovi
ded.
12 /
16
OU
TPU
T P
OW
ER
INP
UT
PO
WE
RIn
put C
ord
Inpu
t Plu
g Vo
ltage
(VA
C)
Volta
ge (V
AC
)
10ft/
3.0m
IEC
603
093
Pha
se
Pha
se
Rat
ed A
mps
208-
240
Max
. Con
t. A
mps
Max
. Con
t. A
mps
4050
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
208-
240/
208-
240
Inpu
t/B
ranc
hR
ecep
tacl
e Ty
pe(Q
uant
ity)
1 / 1
1 / 1
1 / 1
1 / 1
1 / 1
1 / 1
1/1
1/2
1/3
2/4
2/5
2/6
Per
Rec
epta
cle
Type
Per
Rec
epta
cle
Per
Bra
nch
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
IEC
-C13
(7) /
IEC
-C19
(1)
20
12 /
1620
12 /
1620
12 /
1620
12 /
1620
12 /
1620
Liebert MPH Product Selection Guide - Managed Rack PDUs
27
4.0 LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS
4.1 Overview - Managed Rack PDUs
The Liebert MPH Managed Rack PDU system delivers power distribution, branch monitoring and receptacle control for IT devices. Liebert MPH Rack PDUs, with remote monitoring and/or control capabilities for power distribution at the load/equipment level, are designed to support the growth in rack electrical needs while meeting the new demands for remote power management.
The Liebert MPH monitors electrical attributes of an individual Rack PDU, including real-time remote and (optional) local display of monitoring of aggregate and branch electrical parameters (status, thresholds, alarms) including voltage, amps, kW, and kW-hr. Liebert MPH features include branch load monitoring and control for continuous uptime and minimum disruptions; expandable monitoring interface providing simplified growth management; rugged construction; and the convenience of being factory-installed in the Knurr rack enclosure system.
The Liebert MPH includes an input power cord with appropriate input plug connection and hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions are also provided. Liebert MPH Managed Rack PDUs are available in rack mount and vertical zero-U form factors and are painted black.
Liebert MPH – Managed Rack PDUs / Liebert MPH-NB Systems (Branch Monitoring Only)
Liebert MPH-NB series Rack PDUs provide local and remote monitoring of individual PDU volts, amps, watts, and kilowatt-hours.
Liebert MPH – Managed Rack PDUs / Liebert MPH-NC (Monitoring & Receptacle Control)
Liebert MPH-NC series power strips provide the same features and functionality as the Liebert MPH-NB series with the additional capability of remote on/off control of individual receptacles. Local receptacle power on-off status is provided through an LED display.
Liebert MPH – Managed Rack PDUs – ALL Liebert MPH Systems
All Liebert MPH systems are provided with a factory-integrated Liebert RPC (Rack PDU Card RPC-1000) that provides Web-based remote monitoring via a direct IP network connection, Rack PDU Array™ interface connection to three additional Liebert MPH or Liebert MPX systems to allow viewing of up to four Rack PDUs on a single IP connection, an environmental sensor port, and a port for connection to the optional local display. Local display monitoring is provided via the optional RPC BDM (Basic Display Module) and integrated audible alarm. See 5.5 - Adaptive Rack PDU Optional Accessories for further details. Each Liebert MPH unit is provided with basic rack mounting provisions to meet a range of installation needs.
The Liebert MPH fits most standard 600mm width network equipment rack enclosures. Product fit should be confirmed for each application.
Liebert MPH Product Selection Guide - Managed Rack PDUs
28
4.2 Specifications - Liebert MPHTable 3 Specifications - Liebert MPH
Part Number
INPUT OUTPUT
FormFactor
Voltage(VAC)
RatedAmps
Max.Continuous
Amps kW* Phase PlugReceptacle/Socket
Configuration
Branch Monitoring
MPH-NBR09AXXC30 120 20 16 1.9 1 NEMA L5-20P (9) NEMA 5-20R T-Slot Rack mount
MPH-NBV27AXXC30 120 20 16 1.9 1 NEMA L5-20P (27) NEMA 5-20R T-Slot Vertical
MPH-NBR09AXXD30 120 30 24 2.8 1 NEMA L5-30P (9) NEMA 5-20R T-Slot Rack mount
MPH-NBV27AXXD30 120 30 24 2.8 1 NEMA L5-30P (27) NEMA 5-20R T-Slot Vertical
MPH-NBR09NXXE30 208-240 20 16 3.3 1 NEMA L6-20P (9) IEC-C13 Rack mount
MPH-NBV27NXXE30 208-240 20 16 3.3 1 NEMA L6-20P (27) IEC-C13 Vertical
MPH-NBR09NXXF30 208-240 30 24 4.9 1 NEMA L6-30P (9) IEC-C13 Rack mount
MPH-NBV27NXXF30 208-240 30 24 4.9 1 NEMA L6-30P (27) IEC-C13 Vertical
MPH-NBV27NOXF30 208-240 30 24 4.9 1 NEMA L6-30P (21) IEC-C13 & (6) IEC-C19
Vertical
MPH-NBV27NXXJ30 208-240 30 24 8.6 3 NEMA L15-30P (27) IEC-C13 Vertical
MPH-NBV27NOXJ30 208-240 30 24 8.6 3 NEMA L15-30P (21) IEC-C13 &(6) IEC-C19 Vertical
MPH-NBV27AMXH30 120/208 30 24 8.6 3 NEMA L21-30P(15) IEC-C13,
(6) NEMA 5-20 T-slot &(6) IEC-C19
Vertical
MPH-NBV27AXXH30 120/208 30 24 8.6 3 NEMA L21-30P (27) NEMA 5-20R T-Slot Vertical
MPH-NBV27ANXH30 120/208 30 24 8.6 3 NEMA L21-30P(21) IEC-C13 &
(6) NEMA 5-20R T-Slot Vertical
MPH-NBV27NXXH30 120/208 30 24 8.6 3 NEMA L21-30P (27) IEC-C13 Vertical
MPH-NBV27NOXH30 120/208 30 24 8.6 3 NEMA L21-30P (21) IEC-C13 & (6) IEC-C19
Vertical
Receptacle Control
MPH-NCR09AXXC30 120 20 16 1.9 1 NEMA L5-20P (9) NEMA 5-20R T-Slot Rack mount
MPH-NCV27AXXC30 120 20 16 1.9 1 NEMA L5-20P (27) NEMA 5-20R T-Slot Vertical
MPH-NCR09AXXD30 120 30 24 2.8 1 NEMA L5-30P (9) NEMA 5-20R T-Slot Rack mount
MPH-NCV27AXXD30 120 30 24 2.8 1 NEMA L5-30P (27) NEMA 5-20R T-Slot Vertical
MPH-NCR09NXXE30 208-240 20 16 3.3 1 NEMA L6-20P (9) IEC-C13 Rack mount
MPH-NCV27NXXE30 208-240 20 16 3.3 1 NEMA L6-20P (27) IEC-C13 Vertical
MPH-NCR09NXXF30 208-240 30 24 4.9 1 NEMA L6-30P (9) IEC-C13 Rack mount
MPH-NCV27NXXF30 208-240 30 24 4.9 1 NEMA L6-30P (27) IEC-C13 Vertical
MPH-NCV27NOXF30 208-240 30 24 4.9 1 NEMA L6-30P (21) IEC-C13 & (6) IEC-C19
Vertical
MPH-NCV27NXXJ30 208-240 30 24 8.6 3 NEMA L15-30P (27) IEC-C13 Vertical
MPH-NCV27NOXJ30 208-240 30 24 8.6 3 NEMA L15-30P (21) IEC-C13 &(6) IEC-C19 Vertical
MPH-NCV27AMXH30 120/208 30 24 8.6 3 NEMA L21-30P(15) IEC-C13,
(6) NEMA 5-20 T-slot &(6) IEC-C19
Vertical
MPH-NCV27AXXH30 120/208 30 24 8.6 3 NEMA L21-30P (27) NEMA 5-20R T-Slot Vertical
MPH-NCV27ANXH30 120/208 30 24 8.6 3 NEMA L21-30P(21) IEC-C13 &
(6) NEMA 5-20R T-Slot Vertical
MPH-NCV27NXXH30 120/208 30 24 8.6 3 NEMA L21-30P (27) IEC-C13 Vertical
MPH-NCV27NOXH30 120/208 30 24 8.6 3 NEMA L21-30P (21) IEC-C13 & (6) IEC-C19
Vertical
All input cords are 10 ft. (3m) in length.* Formulas used to calculate the kW:
For single-phase: input voltage x max continuous amps = wattsFor three-phase: input voltage x max continuous amps x 1.73 = watts
Liebert MPH Product Selection Guide - Managed Rack PDUs
29
4.3 Model Number Configuration - Liebert MPH
Example: MPH N B R 09 AX XC 30
• Prefix: MPH• Region: N = North American• Type: B = Branch Monitoring
C = Controlled Receptacles• Mounting: V = Vertical
R = Rack mount• Output Power:
• Quantity Receptacles (Total):09 or 27
• Receptacle Type(s)—2 characters (each set):A = 5-20R T-SlotN = IEC-C13O = IEC-C19
Note: Second character indicates a second receptacle type (X if no additional type chosen) • Input Power:
• Plug Type: • First character = X• Second character:
C = L5-20PD = L5-30PE = L6-20PF = L6-30PH = L21-30PJ = L15-30P
• Cord Length:30 = 3.0m (10 ft.)
Liebert MPH Product Selection Guide - Managed Rack PDUs
30
4.4 Managed Rack PDU Optional Cord Sets and Cable Restraints
Output Cord Sets
Output cord sets are available to support conversion of Rack PDU power output receptacles to alter-native power output connections and to support Rack PDU output expansion capabilities.
Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs.
Input Cord Sets
Input cord sets are available to support conversion of Rack PDU power input connections to alterna-tive power input connections. Conversion of power input can be provided on Rack PDUs with L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug.
Cable Restraints (Liebert MPH - Vertical Systems)
Cable restraints are available to secure user equipment power cord connections to IEC-C13 recepta-cles. The Liebert MPH supports all vertical-mount models with IEC-C13 receptacles or a combination of IEC-C13 plus IEC-C19 receptacles. The cable restraint system includes three tie-down brackets for receptacle groups along with cable ties to secure individual input user equipment power cables.
Table 4 Cord sets and cable restraints - Liebert MPH
Cord Sets and Cable Restraints
Output Cord Sets - Power Output Conversion
539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3.3 ft. (1m)
539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m)
539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3.3 ft. (1m)
539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m)
Input Cord Sets - Power Input Conversion
539031G12 Input Cord Set - Power Input Conversion - L5-20P to 5-20P, 1 ft. (0.3m)
Cable Restraints IEC-C13 (Liebert MPH - Vertical Systems)
11858KIT Cable Restraints - MPH Vertical Systems with IEC-C13 receptacles
Liebert MPH Product Selection Guide - Managed Rack PDUs
31
4.5 Dimensional Drawings - Managed Rack PDUs
Figure 23 Liebert MPH rack mount power strip
Circ
uit B
reak
er20
Am
p
Lieb
ert
MP
HP
ower
Dis
tribu
tion
98
76
54
32
1
PN
: RP
C-1
000
HID
16
11
Aud
ible
Ala
rm
Sile
nce
FRO
NT
VIE
W
18.3
" (46
5mm
)
1.7"
[44m
m
RP
C C
omm
unic
atio
n C
ard
L5-2
0P(2
Pol
e, 3
Wire
)
20A
Inpu
t Bre
aker
Inpu
t Plu
gR
EA
R V
IEW
17.2
" (43
8mm
)
Out
put
Rec
epta
cles
0.2"
(6m
m)
1.2"
(32m
m)
7.0"
(178
mm
)
AG
EN
CY
:U
L/C
-UL
List
ed to
UL6
0950
-1R
oHS
Com
plia
nt (R
educ
tion
of H
azar
dous
Sub
stan
ces)
EN
VIR
OM
EN
TAL:
Ope
ratin
g: 3
2°F-
131°
F (0
°C-5
5°C
) non
-con
dens
ing,
non
-cor
rosi
ve, 5
% -
95%
RH
Sto
rage
Tem
pera
ture
: -4°
F-14
0°F
(-20
°C to
60°
C)
NO
TES
:1.
Uni
t Dim
ensi
ons:
1.7
" H x
7.0
" D x
17.
2" W
(44m
m x
178
mm
x 4
38m
m)
2. U
nit W
eigh
t: 7.
5lb.
(3.4
kg)
3. S
hipp
ing
Dim
ensi
ons:
22.
0" H
x 9
.0" D
x 2
4.1"
W (5
59m
m x
228
mm
x 6
12m
m)
4. S
hipp
ing
Wei
ght:
8.5l
b. (3
.9kg
)5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l and
loca
l ele
ctric
cod
es.
MP
H-N
CR
09A
XX
C30
Rev
. 3
Inpu
t Cor
dIn
put P
lug
Pha
se Pha
seVol
tage
(VA
C)
Vol
tage
(VA
C)
10ft/
3.0m
L5-2
0P1
120
Rat
ed A
mps
20
20
INP
UT
PO
WE
R
OU
TPU
T P
OW
ER
Bra
nch
Rec
epta
cle
Type
(Qua
ntity
)
Per
Rec
epta
cle
Type
5-20
R (9
)P
er R
ecep
tacl
e
Max
Con
t. A
mps
Max
Con
t. A
mps
120
16
16
Per
Bra
nch
TOP
VIE
W
Liebert MPH Product Selection Guide - Managed Rack PDUs
32
Figure 24 Liebert MPH vertical power strip
Lie
ber
t M
PHP
ower
Dis
tribu
tion
Bra
nch
3C
ircu
it B
reak
er20
Am
pere
Bra
nch
2C
ircu
it B
reak
er20
Am
pere
Bra
nch
1C
ircu
it B
reak
er20
Am
pere
PN:
RPC
-100
0HI
D16
Bra
nch
3
98
76
54
32
1
Bra
nch
2
98
76
54
32
1
Bra
nch
1
98
76
54
32
1
Bra
nch
3(9
) 5-2
0RB
ranc
h 3
(9) 5
-20R
Bra
nch
3(9
) 5-2
0R
RP
CC
omm
unic
atio
nC
ard
1.9"
(50m
m)
FRO
NT
VIE
W
RE
AR
VIE
W
SID
E V
IEW
20A
Bra
nch
Circ
uit B
reak
ers
68.1
" (17
30m
m)
3.4
(86m
m)
3.4
(86m
m)
12.3
(312
mm
)12
.3 (3
12m
m)
0.2"
(6m
m)
1.2"
(32m
m)
Verti
cal M
ount
ing
Bra
cket
(See
Not
e 6)
Tool
less
Mou
ntin
gB
utto
n (S
ee N
ote
6)9.
2" (2
35m
m)
0.99
(25m
m)
3.1"
(80m
m)
2.2"
(57m
m)
L5-2
0P(2
Pol
e, 3
Wire
)
AG
EN
CY:
UL/
C-U
L Li
sted
to U
L609
50-1
RoH
S C
ompl
iant
(Red
uctio
n of
Haz
ardo
us S
ubst
ance
s)E
NV
IRO
NM
EN
TAL:
Ope
ratin
g: 3
2°F
to 1
31°
F (0
°C to
55°
C) n
on-c
onde
nsin
g, n
on-c
orro
sive
,5%
- 95
% R
HS
tora
ge T
empe
ratu
re: -
4°F
to 1
40°F
(-20
° C
to 6
0° C
)N
OTE
S:
1. U
nit D
imen
sion
s: 6
8.1"
(173
0mm
) H x
3.1
" (80
mm
) D x
1.9
" (50
mm
) W2.
Uni
t Wei
ght:
18lb
. (8.
2kg)
3. S
hipp
ing
Dim
ensi
ons:
72.
2" (1
962m
m) H
x 6
.2" (
159m
m) D
x 1
0.7"
(273
mm
) W4.
Shi
ppin
g W
eigh
t: 20
lb. (
9.1k
g)5.
All
wiri
ng is
to b
e in
com
plia
nce
with
nat
iona
l and
loca
l ele
ctric
cod
es.
6. O
nly
one
mou
ntin
g op
tion
requ
ired
to b
e us
ed a
t a ti
me.
Ver
tical
mou
ntin
gbr
acke
ts a
nd to
olle
ss b
utto
ns s
how
n to
geth
er fo
r ref
eren
ce o
nly.
MP
H-N
CV
27A
XX
C30
Rev
. 2
Inpu
t Cor
dIn
put P
lug
L5-2
0P10
ft/3
.0m
Volta
ge (V
AC
)
Volta
ge (V
AC
)
Pha
se
Pha
se
Rat
ed A
mps
Max
Con
t. A
mps
Max
Con
t. A
mps
Bra
nch
5-20
R (9
)
5-20
R (9
)
5-20
R (9
)
Rec
epta
cle
Type
(Qua
ntity
)
1 2 3
1 1 1 1Per
Rec
epta
cle
Type
Per
Rec
epta
cle
Per
Bra
nch
20
20
2020
16
16
1616
120
120
120
120
INP
UT
PO
WE
R
OU
TPU
T P
OW
ER
Liebert MPX - Adaptive Rack PDUs
33
5.0 LIEBERT MPX - ADAPTIVE RACK PDUS
5.1 Overview - Adaptive Rack PDUs
The Liebert MPX Adaptive Rack PDU system delivers break-through flexibility, availability and total cost of ownership. The Liebert MPX enables users to respond to and manage changing rack power and management environments. The Liebert MPX provides users the ability to size their Rack PDU sys-tem to support initial requirements and then adapt as connectivity, capacity and/or functionality needs change. The Liebert MPX is based on a patent-pending design built on a power / communication bus and input/output power module strategy.
The Liebert MPX Adaptive Rack PDU is composed of several key building blocks and support mod-ules. The Liebert MPX is built on the MPX PRC (Power Rail Chassis) that distributes power and com-munications to all support modules, acts as a backplane to mount support modules and offers provisions to physically mount the Liebert MPX in a network rack. Input power is connected and delivered to the Liebert MPX system via the MPX PEM (Power Entry Module). Output power connec-tivity and communications management level is defined by the MPX BRM (Branch Receptacle Mod-ules). MPX BRM power connectivity includes NEMA receptacles and IEC sockets. MPX BRM communications include Branch Monitoring and Receptacle Management versions. Network commu-nications, sensor and/or local display interface are provided by the Liebert RPC (Rack PDU Card) that mounts in the MPX PEM. The Liebert RPC provides connection to an optional RPC BDM (Basic Dis-play Module) for local status / alarm viewing. Module versions for North American and European applications are available.
The Liebert MPX is provided as separate ship-loose modules for user on-site configuration. The Lie-bert MPX is designed for simple and quick configuration and reconfiguration. Preconfigured systems are available as an Special Feature Authorization (SFA) when ordered as factory installed in Knurr rack enclosure systems.
The major Liebert MPX system components are described in the following sections:
• 5.2 - MPX PRC (Power Rail Chassis)• 5.3 - MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord)• 5.4 - MPX BRM (Branch Receptacle Module)
Liebert MPX - Adaptive Rack PDUs
34
Figure 25 Liebert MPX 1880 and 1035 models and components
MPX PEM,Fixed Capacity
Liebert MPX,1880mmLiebert PRC chassis
MPX BRM
MPX IPC
RPC BDM
Liebert RPC
MPX PEM,Variable Capacity
Liebert MPX, 1035mm Liebert PRC chassis
Liebert MPX - Adaptive Rack PDUs
35
5.2 MPX PRC (Power Rail Chassis)
The MPX PRC distributes power and communications to the installed Liebert MPX modules. The MPX PRC supports both single-phase power input up to 20A and three-phase up to 60A. It includes provisions to mount and secure an input power module (MPX PEM) and output receptacle modules (MPX BRM). It is available in lengths to accommodate typical 23U or 42U network racks: 1035mm (40.75 in.) for 23U and 1880mm (74 in.) for 42U. The MPX PRC includes zero-U mounting provisions that accommodate most rack designs. The MPX PRC is provided with cover / spacers to assist users with positioning for future MPX BRM module additions.
Figure 26 MPX PRC (Power Rail Chassis)
Power BusFRONT SIDESection of MPX PRC
Communication Bus
ModuleConnector Slot
T-slots in the back of the MPX PRC (Power Rail Chassis) accept spring nuts for easy mounting
REAR SIDESection of MPX PRC
Liebert MPX - Adaptive Rack PDUs
36
5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord)
The MPX PEM provides input power to the Liebert MPX system and includes provisions for addition of the Liebert RPC (Rack PDU Card) to support remote and local communications. The MPX PEM is available in two versions: Variable Capacity and Fixed Capacity.
The MPX PEM Variable Capacity version allows the user to select and change power input via differ-ent MPX IPCs. The MPX IPC includes cord, MPX PEM connector, and input plug. The MPX IPC is available in multiple versions supporting up to 30 amps including single-phase North American 120VAC and 208VAC and three-phase North American 208/120VAC connections.
The MPX PEM Fixed Capacity version supports rated input capacities from 40 up to 60 amps with fixed cord and plug connections. All MPX PEMs include an audible over current alarm with local reset. One MPX PEM is required per Liebert MPX Rack PDU.
• Variable Capacity MPX PEMs are 220mm in length for application on both short (1035mm) and standard (1880mm) MPX PRC systems.
• Fixed Capacity systems are 266mm in length for application on standard (1880mm) MPX PRCs.
5.4 MPX BRM (Branch Receptacle Module)
The MPX BRM provides output power distribution to user load equipment and remote management / monitoring of that equipment. The MPX BRM includes output receptacles (NEMA and IEC) and is overload-protected. The MPX BRM is available in two versions: Branch Monitoring and Receptacle Management. The MPX BRM Branch Monitoring version supports monitoring of its aggregate branch electrical and energy parameters (status, thresholds, and alarms) including voltage, amps, kW, and kW-hr. The MPX BRM Receptacle Management version supports monitoring of individual receptacle electrical and energy parameters (status, thresholds, and alarms)—including voltage, amps, kW and kW-hr—and supports on-off power control of individual receptacles, along with the aggregate branch monitoring provided on MPX BRM Branch Monitoring systems.
MPX BRMs are hot-swappable to allow user installation without powering down the Liebert MPX system. Each MPX BRM includes a display that automatically assigns and displays a Branch identifi-cation number to the MPX BRM when added to an active Liebert MPX system. Each MPX BRM is overload-protected by 20 Amp branch-rated hydraulic magnetic circuit breakers that support UL60950 requirements. The breakers are protected from inadvertent tripping by requiring tool inser-tion to manually open and from accidental impact damage by a protection body/cover.
MPX BRMs are offered in line-to-line and line-to-neutral power configurations. These configurations support different power input requirements and provide support for load balancing for three-phase input power systems.
Up to three (3) MPX BRMs can be deployed on a Liebert MPX system utilizing the 1035mm MPX PRC for typical 23U racks and up to six (6) MPX BRMs for systems utilizing the 1880mm MPX PRC for typical 42U racks. All MPX BRMs are 266mm in length.
Liebert MPX - Adaptive Rack PDUs
37
5.5 Adaptive Rack PDU Optional Accessories
5.5.1 Cord Sets and Cable Restraints
Output Cord Sets
Output cord sets are available to support conversion of Rack PDU power output receptacles to alter-native power output connections and to support Rack PDU output expansion capabilities.
Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs.
Cable Restraints (Liebert MPX Systems)
Cable restraints are available to secure user equipment power cord connections to IEC-C13 recepta-cles. The Liebert MPX supports all models of the MPX BRM with IEC-C13 receptacles and includes individual cable restraint clips to support individual receptacles. Twelve restraint clips are provided per option. The Liebert MPX cable restraint supports most IEC-C14 plugs that connect to the IEC-C13 receptacles.
5.5.2 Liebert RPC™ (RPC-1000) and Accessories
The Liebert RPC (Rack PDU Card) is a network interface card that provides network connectivity to the Liebert Rack PDU family of products.
The Liebert RPC can be installed in Adaptive and Managed versions of Liebert Rack PDUs to provide network monitoring and control capabilities. The Liebert RPC is a factory-installed standard feature of the Liebert MPH; it is an option for the Liebert MPX.
In addition, the Liebert RPC serves as the integration point for several rack accessory products. Available options that connect to the card include the RPC BDM (Basic Display Module) and a tem-perature/humidity sensor.
Cord Sets and Cable Restraints
Output Cord Sets - Power Output Conversion
539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m)
539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m)
539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m)
539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m)
Cable Restraints IEC-C13 (Liebert MPX Systems)
039102169 Cable Restraints - MPX BRM with IEC-C13 receptacles (Set of 12)
Liebert MPX - Adaptive Rack PDUs
38
5.5.3 Part Numbers for Liebert RPC and Accessories
• Liebert RPC (Rack PDU Card): • RPC-1000
• RPC BDM (Basic Display Module): • RPC-BDM-1000
• Liebert SN Integrated Environmental Sensors: • SN-Z01 - Single Temperature Probe; 12 ft. (3.66m) length cable• SN-Z02 - Three Temperature Probes; 17 ft. (5.18m) length cable• SN-Z03 - Three Temperature Probes and Single Humidity Probe; 17 ft. (5.18m) length cable
Liebert SN Modular Environmental Sensors:• SN-T - Single Temperature Probe (1 probe)• SN-TH - Single Temperature Probe and Single Humidity Probe (2 probes)• SN-2D - Door Switch, 2 inputs (1 probe)• SN-3C - Digital Input, 3 inputs (1 probe)
5.5.4 Ports on the Liebert RPC
Figure 27 shows the four individual ports on the Liebert RPC.
Each port is designed for only one type of connection. See the Liebert RPC user manual, SL-20825, for details on using these ports.
Figure 27 Liebert RPC ports
External Sensor port
Display port
Expansion/Management port
LAN port
Liebert MPX - Adaptive Rack PDUs
39
5.5.5 Liebert RPC Capabilities and Benefits
The Liebert RPC offers the following capabilities and benefits:
Web Support
The Liebert RPC delivers Web management and control to Liebert Rack PDU equipment. All autho-rized users will be able to view status information on their network.
SNMP Support
The Liebert RPC enables SNMP management of Liebert Rack PDU equipment. To integrate the card into an SNMP implementation, compile the Liebert Global Products MIB on your Network Manage-ment System (NMS).
The Liebert Global Products MIB can be downloaded from:
www.liebert.com
Liebert Nform™
Utilizing the SNMP and Web technologies built into the Liebert RPC, Liebert Nform will centrally manage event notifications, access critical system information and manage the power delivered to your critical devices.
A downloadable edition is available online at:
nform.liebert.com
Liebert SiteScan® Web
The Liebert RPC integrates with Liebert SiteScan Web software to monitor and analyze trends to ensure high-availability operation of critical facilities.
For more information on Liebert SiteScan Web, visit the Web page at:
sitescan.liebert.com
Liebert MPX - Adaptive Rack PDUs
40
5.5.6 RPC BDM—Basic Display Module
The RPC BDM is an optional device with an LCD for local viewing of status and alarms of up to four Liebert MPX or Liebert MPH PDUs. It connects to Liebert RPC with a factory-supplied cable that is 6.5 ft. (2m) long. The portable unit can be mounted on a wall for viewing particular units. The RPC BDM provides local display of electrical status for all connected Liebert MPX (and Liebert MPH) systems, MPX BRMs and individual receptacles, if the PDU version permits it. Information is accessed via a navigation switch on the RPC BDM.
For model number and other details, refer to 5.5.3 - Part Numbers for Liebert RPC and Accesso-ries and the Liebert RPC user manual, SL-20825, available at the Liebert Web site: www.liebert.com
Figure 28 RPC BDM
5.5.7 Temperature/Humidity Sensor
A temperature/humidity sensor is available to monitor conditions in the rack. The sensor mounts without tools. It connects to the Liebert RPC with a factory-supplied Ethernet cable and can be moni-tored over a network.
Figure 29 Temperature/humidity sensor
RPC BDM
Jog Wheel on Top of Unit to Navigate Display
Communication Port on Sideof Unit Connects to Liebert RPC
Sensor
Support base
Sensor support
Sensor
Knurr framemember
Tool-less fastener
Sensor installed in rack
Liebert MPX System Product Selection Guide
41
6.0 LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE
6.1 STEP 1 - Select an MPX PRC (Quantity x 1)
To select an MPX PRC (Power Rail Chassis), refer to:
Specifications - MPX PRC
Model Number Configuration - MPX PRC
Example: MPXPRC-V1035XXX
• Prefix: MPXPRC• Mounting: V = Vertical• Length: 1035 = Short (40.75"; 1035mm)
1880 = Standard (74"; 1880mm)• Placeholder: XXX
MPXPRC-V1035XXX: Max 8.6 kW, limited to 3 MPX BRM modules
Input: Single-Phase and Three-Phase 5-wire / 20-30 Amp / 120/208VAC
Rack Fit: Typical 23U, most 600mm wide
MPXPRC-V1880XXX: Max 17.2 kW, limited to 6 MPX BRM modules
Input:Single-Phase and Three-Phase 5-wire / 20-60 Amp / 120/208VAC
Rack Fit: Typical 42U, most 600mm wide
Liebert MPX with 1880mmLiebert PRCchassis
Liebert MPX with 1035mm Liebert PRCchassis
Liebert MPX System Product Selection Guide
42
6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1)
To select an MPX PEM (Power Entry Module)—and an MPX IPC (Input Power Cord) for a Variable Capacity MPX PEM system—refer to:
• The appropriate table in 6.5 - System Selection Guide for the MPX PEM (Power Entry Module):• Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX• Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30• Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30• Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30
• The following information:
Specifications - MPX PEM
Model Number Configuration - MPX PEM
Example: MPXPEM-NVAXXAXX
• Prefix: MPXPEM• Region: N = North American• Type: V = Variable Capacity
H = Fixed Capacity• Size: A = Base (220mm) – Variable Capacity version
B = Standard (266mm) – Fixed Capacity version• Communications:
X = Future Use• Input Power:
• Available Capacity or Plug Type:XA = 30 ampsXV = 50 amps, 4-wire (CS8365C)XX = 60 amps, 4-wire (IEC60309)XW = 60 amps, 5-wire (IEC60309)
• Cord Length:XX = No integrated cord (Requires MPX IPC)30 = 3.0m (10 ft.)
Input Power MPX PEM Selection MPX IPC Input Plug
120VAC / 1-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXD30XXX L5-30P
208VAC / 1-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXF30XXX L6-30P
208VAC / 3-Phase / 30 AMP MPXPEM-NVAXXAXX MPXIPC-NXJ30XXX L15-30P
120/208VAC / 3-Phase / 20 Amp MPXPEM-NVAXXAXX MPXIPC-NXG30XXX L21-20P
120/208VAC / 3-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXH30XXX L21-30P
MPX PEM (Power Entry Module)
MPXPEM-NVAXXAXX Power Entry Module - Variable Capacity, North American, 120 or 208VAC single-phase and/or 208-240VAC three-phase input up to 30Amp
MPXPEM-NHBXXV30 Power Entry Module - Fixed Capacity, North American, 208-240VAC, three-phase 4-wire (L-L-L-G), 50Amp input, CS8365C plug, 10 ft. (3m) cord
MPXPEM-NHBXXX30Power Entry Module - Fixed Capacity, North American, 208-240VAC, three-phase 4-wire (L-L-L-G), 60Amp input, IEC60309 Pin-Sleeve plug, 10 ft. (3m) cord
MPXPEM-NHBXXW30 Power Entry Module - Fixed Capacity, North American, 120/208VAC, three-phase 5-wire (L-L-L-N-G), 60Amp input, IEC60309 Pin-Sleeve plug, 10 ft. (3m) cord
MPX PEM,Fixed Capacity
MPX PEM,Variable Capacity
Liebert MPX System Product Selection Guide
43
Specifications - MPX IPC (MPX PEM Variable Capacity Systems ONLY)
Model Number Configuration - MPX IPC (MPX PEM Variable Capacity Systems ONLY)
Example: MPXIPC-NXG30XXX
• Prefix: MPXIPC• Region: N = North American• Input Power and Connection:
• Plug Type: XD = L5-30PXF = L6-30PXJ = L15-30PXG = L21-20PXH = L21-30P
• Cord Length: 30 = 3.0m (10 ft.)
• Placeholder: XXX
MPX IPC (Input Power Cord)
120VAC – Single-Phase Input / Output
MPXIPC-NXD30XXXInput Power Cord - North American, 30Amp - 120VAC - Single-Phase; NEMA L5-30P Locking plug; 10 ft. (3m) length cord
208VAC – Single-Phase Input / Output
MPXIPC-NXF30XXXInput Power Cord - North American, 30Amp - 208-240VAC - Single-Phase;NEMA L6-30P Locking plug; 10 ft. (3m) length cord
208VAC – Three-Phase Input / 208VAC Single-Phase Output
MPXIPC-NXJ30XXXInput Power Cord - North American, 30Amp - 208-240VAC - Three-Phase, 4-wire;NEMA L15-30P Locking plug; 10 ft. (3m) length cord
208VAC – Three-Phase Input / 120/208VAC Single-Phase Output
MPXIPC-NXG30XXXInput Power Cord - North American, 20Amp - 120/208VAC - Three-Phase; NEMA L21-20P Locking plug; 10 ft. (3m) length cord
MPXIPC-NXH30XXXInput Power Cord - North American, 30Amp - 120/208VAC - Three-Phase; NEMA L21-30P Locking plug; 10 ft. (3m) length cord
MPX IPC
MPX PEM,Variable Capacity
Liebert MPX System Product Selection Guide
44
6.3 STEP 3 - Select an MPX BRM
To select an MPX BRM (Branch Receptacle Module), refer to:
• The appropriate table in 6.5 - System Selection Guide for the MPX PEM (Power Entry Module):• Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX• Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30• Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30• Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30
• The following MPX BRM quantity definitions:
• If needed, refer to the MPX BRM specifications in Table 9
Model Number Configuration - MPX BRM
Example: MPXBRM-NRBD4O31
• Prefix: MPXBRM• Region: N = North American• Type: B = Branch Monitoring
R = Receptacle Management• Size and OL Protection:
• Size: B = Standard (266mm)• Voltage Rating and OL Protection:
A = 120V/20AD = 208-240V/20A
• Output Power: • Quantity Receptacles:
4, 6• Receptacle Type:
A = 5-20R T-slotN = IEC-C13O = IEC-C19
• Phase Configuration: 1N = L1-N2N = L2-N3N = L3-N12 = L1-L223 = L2-L331 = L3-L1
MPX PRC selected Single-Phase Input Three-Phase Input
MPXPRC-V1035XXX 3 MPX BRM modules maximum 1 x BRM per Lx-Lx* (total 3 max)
MPXPRC-V1035XXX 6 MPX BRM modules maximum 2 x BRM per Lx-Lx* (total 6 max)
* Required for phase load balancing
MPX BRM
Liebert MPX System Product Selection Guide
45
6.4 STEP 4 - Select Communication Options
Choose from the following options for the Liebert MPX:
• Liebert RPC (Rack PDU Card) part number:• RPC-1000
• RPC BDM (Basic Display Module) part number:• RPC-BDM-1000
• Liebert SN Integrated and Modular Environmental Sensor part numbers:Integrated Sensors
• SN-Z01 - Single Temperature Probe; 12 ft. (3.66m) length cable
• SN-Z02 - Three Temperature Probes; 17 ft. (5.18m) length cable
• SN-Z03 - Three Temperature Probes and Single Humidity Probe; 17 ft. (5.18m) length cable
Modular Sensors• SN-T - Single Temperature Probe (1 probe)• SN-TH - Single Temperature Probe and
Single Humidity Probe (2 probes)• SN-2D - Door Switch, 2 inputs (1 probe)• SN-3C - Digital Input, 3 inputs (1 probe)
The Liebert RPC is required for the other two options, the RPC BDM and Liebert SN integrated sensor.
RPC BDM
Liebert RPC
Liebert SN(Integrated Sensor)
Liebert SN(Modular Sensor)
Liebert MPX System Product Selection Guide
46
6.5 System Selection Guide
Use the appropriate table as a guide to select components that are compatible with each MPX PEM:
• Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX• Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30• Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 • Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30
Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX
MPX PEMPart Number
ModuleVoltage
RatedAmps
Max.Continuous
AmpsInput
ConnectionInput
Phases
ModuleLength(mm)
MPXPEM-NVAXXAXX* 120/208or 208-240
30 24 Variable
Single-Phaseor Three-Phase
depending on the MPX IPC selection
220
* No fixed cord (requires MPX IPC)
Compatible MPX PRCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
Amps
Max. # MPX BRMs Supported
PhaseConfiguration
OverallLength
MPXPRC-V1035XXX 120/208or 208-240 60 48
3 Single-Phase& Three-Phase
1035mm, 23U
MPXPRC-V1880XXX 6 1880mm, 42U
Compatible MPX IPCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
Amps Input PlugPhase
Configuration
CordLengthft. (m)
MPXIPC-NXD30XXX 120 30 24 NEMA L5-30P L1-N-G 10 (3.0)
Compatible MPX BRMfor given MPX IPC:
ModuleVoltage
BranchRatedAmps
Max.Continuous
Amps
Quantity& Receptacle
Type
OutputPhase
Configuration
ModuleLength(mm)
Branch Monitoring
MPXBRM-NBBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266
Receptacle Management
MPXBRM-NRBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266
Compatible MPX IPCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
Amps Input PlugPhase
Configuration
CordLengthft. (m)
MPXIPC-NXF30XXX 208-240 30 24 NEMA L6-30P L1-L2-G 10 (3.0)
Compatible MPX BRMfor given MPX IPC:
ModuleVoltage
BranchRatedAmps
Max.Continuous
Amps
Quantity& Receptacle
Type
OutputPhase
Configuration
ModuleLength(mm)
Branch Monitoring
MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
Receptacle Management
MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
Liebert MPX System Product Selection Guide
47
Compatible MPX IPCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
AmpsInputPlug
PhaseConfiguration
CordLengthft. (m)
MPXIPC-NXJ30XXX 208-240 30 24 NEMA L15-30P L1-L2-L3-G 10 (3.0)
Compatible MPX BRMfor given MPX IPC:
ModuleVoltage
BranchRatedAmps
Max.Continuous
Amps
Quantity& Receptacle
Type
OutputPhase
Configuration
ModuleLength(mm)
Branch Monitoring
MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Receptacle Management
MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Compatible MPX IPCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
Amps Input PlugPhase
ConfigurationCord Length
ft. (m)
MPXIPC-NXG30XXX 120/208 20 16 NEMA L21-20P L1-L2-L3-N-G 10 (3.0)
Compatible MPX BRMfor given MPX IPC:
ModuleVoltage
BranchRatedAmps
Max.Continuous
Amps
Quantity& Receptacle
Type
OutputPhase
Configuration
ModuleLength(mm)
Branch Monitoring
MPXBRM-NBBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266
MPXBRM-NBBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266
MPXBRM-NBBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266
MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Receptacle Management
MPXBRM-NRBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266
MPXBRM-NRBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266
MPXBRM-NRBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266
MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX (continued)
Liebert MPX System Product Selection Guide
48
Compatible MPX IPCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
Amps Input PlugPhase
Configuration
CordLengthft. (m)
MPXIPC-NXH30XXX 120/208 30 24 NEMA L21-30P L1-L2-L3-N-G 10 (3.0)
Compatible MPX BRMfor given MPX IPC:
ModuleVoltage
BranchRatedAmps
Max.Continuous
Amps
Quantity& Receptacle
Type
OutputPhase
Configuration
ModuleLength(mm)
Branch Monitoring
MPXBRM-NBBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266
MPXBRM-NBBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266
MPXBRM-NBBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266
MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Receptacle Management
MPXBRM-NRBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266
MPXBRM-NRBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266
MPXBRM-NRBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266
MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX (continued)
Liebert MPX System Product Selection Guide
49
Table 6 Selections for Power Entry Module MPXPEM-NHBXXV30
MPX PEMPart Number
ModuleVoltage
RatedAmps
Max.Continuous
AmpsInput
ConnectionInput
Phases
ModuleLength(mm)
MPXPEM-NHBXXV30 208-240V 50 40CS83665C
3-PH, 4-Wire L1-L2-L3-G 266
Compatible MPX PRCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
Amps
Max. # MPX BRMs Supported
PhaseConfiguration
OverallLength
MPXPRC-V1035XXX 120/208or 208-240 60 48
3 Single-Phase& Three-Phase
1035mm, 23U
MPXPRC-V1880XXX 6 1880mm, 42U
Compatible MPX BRMfor given MPX PEM:
ModuleVoltage
BranchRatedAmps
Max.Continuous
Amps
Quantity& Receptacle
Type
OutputPhase
Configuration
ModuleLength(mm)
Branch Monitoring
MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Receptacle Management
MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Liebert MPX System Product Selection Guide
50
Table 7 Selections for Power Entry Module MPXPEM-NHBXXX30
MPX PEMPart Number
ModuleVoltage
RatedAmps
Max.Continuous
AmpsInput
ConnectionInput
Phases
ModuleLength(mm)
MPXPEM-NHBXXX30 208-240V 60 48 IEC603093-PH, 4-Wire L1-L2-L3-G 266
Compatible MPX PRCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
Amps
Max. # MPX BRMs Supported
PhaseConfiguration
OverallLength
MPXPRC-V1035XXX 120/208or 208-240 60 48
3 Single-Phase& Three-Phase
1035mm, 23U
MPXPRC-V1880XXX 6 1880mm, 42U
Compatible MPX BRMfor given MPX PEM:
ModuleVoltage
BranchRatedAmps
Max.Continuous
Amps
Quantity& Receptacle
Type
OutputPhase
Configuration
ModuleLength(mm)
Branch Monitoring
MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Receptacle Management
MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Liebert MPX System Product Selection Guide
51
Table 8 Selections for Power Entry Module MPXPEM-NHBXXW30
MPX PEMPart Number
ModuleVoltage
RatedAmps
Max.Continuous
AmpsInput
ConnectionInput
Phases
ModuleLength(mm)
MPXPEM-NHBXXW30 208-240V 60 48 IEC603093-PH, 5-Wire L1-L2-L3-N-G 266
Compatible MPX PRCfor given MPX PEM:
VoltagesSupported
RatedAmps
Max.Continuous
Amps
Max. #MPX BRMsSupported
InputPhases
OverallLength
MPXPRC-V1035XXX 120/208or 208-240V 60 48
3 Single-Phase& Three-Phase
1035mm, 23U
MPXPRC-V1880XXX 6 1880mm, 42U
Compatible MPX BRMfor given MPX PEM:
ModuleVoltage
BranchRatedAmps
Max.Continuous
Amps
Quantity& Receptacle
Type
OutputPhase
Configuration
ModuleLength(mm)
Branch Monitoring
MPXBRM-NBBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266
MPXBRM-NBBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266
MPXBRM-NBBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266
MPXBRM-NBBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NBBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NBBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NBBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NBBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NBBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Receptacle Management
MPXBRM-NRBA6A1N 120V 20 16 (6) NEMA 5-20R L1-N 266
MPXBRM-NRBA6A2N 120V 20 16 (6) NEMA 5-20R L2-N 266
MPXBRM-NRBA6A3N 120V 20 16 (6) NEMA 5-20R L3-N 266
MPXBRM-NRBD6N12 208-240V 20 16 (6) IEC-C13 L1-L2 266
MPXBRM-NRBD6N23 208-240V 20 16 (6) IEC-C13 L2-L3 266
MPXBRM-NRBD6N31 208-240V 20 16 (6) IEC-C13 L3-L1 266
MPXBRM-NRBD4O12 208-240V 20 16 (4) IEC-C19 L1-L2 266
MPXBRM-NRBD4O23 208-240V 20 16 (4) IEC-C19 L2-L3 266
MPXBRM-NRBD4O31 208-240V 20 16 (4) IEC-C19 L3-L1 266
Liebert MPX System Product Selection Guide
52
6.6 Specifications for Liebert MPX ComponentsTable 9 Specifications - MPX BRM
MPX BRM (Branch Receptacle Module)
Single-Phase Liebert MPX System (MPX PEM) Input Selections
Phase L1 to Neutral (120VAC) Output
Branch Monitoring Support
MPXBRM-NBBA6A1N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Line L1 to Neutral (120VAC)
Receptacle Management Support
MPXBRM-NRBA6A1N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Line L1 to Neutral (120VAC)
Line L1 to L2 (208VAC) Output
Branch Monitoring Support
MPXBRM-NBBD6N12 Branch Monitoring, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC)
MPXBRM-NBBD4O12 Branch Monitoring, (4) IEC-C19 receptacles; Line L1 to L2 (208-240VAC)
Receptacle Management Support
MPXBRM-NRBD6N12 Receptacle Management, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC)
MPXBRM-NRBD4O12 Receptacle Management, (4) IEC-C19 receptacles; Line L1 to L2 (208-240VAC)
Three-Phase Liebert MPX System (MPX PEM) Input Selections
Line L1 to L2 (208VAC) or Phase L1 to Neutral (120VAC) Output
Branch Monitoring Support
MPXBRM-NBBA6A1N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L1 to Neutral (120VAC)
MPXBRM-NBBD6N12 Branch Monitoring, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC)
MPXBRM-NBBD4O12 Branch Monitoring, (4) IEC-C19 receptacles Line L1 to L2 (208-240VAC)
Receptacle Management Support
MPXBRM-NRBA6A1N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L1 to Neutral (120VAC)
MPXBRM-NRBD6N12 Receptacle Management, (6) IEC-C13 receptacles; Line L1 to L2 (208-240VAC)
MPXBRM-NRBD4O12 Receptacle Management, (4) IEC-C19 receptacles Line L1 to L2 (208-240VAC)
Line L2 to L3 (208VAC) or Phase L2 to Neutral (120VAC) Output
Branch Monitoring Support
MPXBRM-NBBA6A2N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L2 to Neutral (120VAC)
MPXBRM-NBBD6N23 Branch Monitoring, (6) IEC-C13 receptacles; Line L2 to L3 (208-240VAC)
MPXBRM-NBBD4O23 Branch Monitoring, (4) IEC-C19 receptacles Line L2 to L3 (208-240VAC)
Receptacle Management Support
MPXBRM-NRBA6A2N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L2 to Neutral (120VAC)
MPXBRM-NRBD6N23 Receptacle Management, (6) IEC-C13 receptacles Line L2 to L3 (208-240VAC)
MPXBRM-NRBD4O23 Receptacle Management, (4) IEC-C19 receptacles Line L2 to L3 (208-240VAC)
Line L3 to L1 (208VAC) or Phase L3 to Neutral (120VAC) Output
Branch Monitoring Support
MPXBRM-NBBA6A3N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L3 to Neutral (120VAC)
MPXBRM-NBBD6N31 Branch Monitoring, (6) IEC-C13 receptacles; Line L3 to L1 (208-240VAC)
MPXBRM-NBBD4O31 Branch Monitoring, (4) IEC-C19 receptacles Line L3 to L1 (208-240VAC)
Receptacle Management Support
MPXBRM-NRBA6A3N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L3 to Neutral (120VAC)
MPXBRM-NRBD6N31 Receptacle Management, (6) IEC-C13 receptacles Line L3 to L1 (208-240VAC)
MPXBRM-NRBD4O31 Receptacle Management, (4) IEC-C19 receptacles Line L3 to L1 (208-240VAC)
Liebert MPX System Product Selection Guide
53
6.7 Dimensional Drawings - Adaptive Rack PDUs
Figure 30 Liebert MPX MPXPRC-1035mm mixed modules
MP
X-P
RC
cove
r/spa
cer
MP
X-B
RM
circ
uit b
reak
erpr
otec
tion
body
10.5
"(2
66m
m)
10.5
"(2
66m
m)
10.5
"(2
66m
m)
8.7"
(220
mm
)
MP
X-B
RM
(Bra
nch
Rec
epta
cle
Mod
ules
)
MP
X-P
EM
(Pow
er E
ntry
Mod
ule)
Inpu
t pow
erco
rd (v
aria
ble)
MP
X-P
RC
(Pow
er R
ail
Cha
ssis
)
40.6
" (10
35m
m)
TOP
VIE
W
SID
E V
IEW
4.1"
(104
mm
)4.
1"(1
04m
m)
2.9"
(75m
m)
2.9"
(75m
m)
MP
X-M
IXM
OD
1035
Rev
. 0
NO
TES
:1.
D
imen
sion
al v
iew
of 1
035m
m M
PX
-PR
C a
pplic
atio
n.2.
R
epre
sent
ativ
e m
odul
e m
ix m
ay n
ot re
flect
use
r sel
ectio
n.3.
O
pera
ting
tem
pera
ture
: 41°
F to
131
°F (5
°C to
55°
C)
4.
Sto
rage
tem
pera
ture
: -13
°F to
185
°F (-
25°C
to 8
5°C
)
Liebert MPX System Product Selection Guide
54
Figure 31 Liebert MPX MPXPRC-1880mm mixed modules
MP
X-P
RC
cove
r/spa
cer
MP
X-B
RM
circ
uit b
reak
erpr
otec
tion
body
10.5
"(2
66m
m)
10.5
"(2
66m
m)
10.5
"(2
66m
m)
10.5
"(2
66m
m)
10.5
"(2
66m
m)
10.5
"(2
66m
m)
10.5
"(2
66m
m)
MP
X-B
RM
(Bra
nch
Rec
epta
cle
Mod
ules
)
MP
X-P
EM
(Pow
er E
ntry
Mod
ule)
Inpu
t pow
erco
rd (f
ixed
)
MP
X-P
RC
(Pow
er R
ail
Cha
ssis
)
74" (
1880
mm
)TO
P V
IEW
SID
E V
IEW
EN
D V
IEW
4.1"
(104
mm
)4.
1"(1
04m
m)
4.1"
(104
mm
)
2.9"
(75m
m)
2.9"
(75m
m)
MP
X-M
IXM
OD
1880
Rev
. 1
NO
TES
:1.
D
imen
sion
al v
iew
of 1
880m
m M
PX
-PR
C a
pplic
atio
n.2.
R
epre
sent
ativ
e m
odul
e m
ix m
ay n
ot re
flect
use
r sel
ectio
n.3.
O
pera
ting
tem
pera
ture
: 41°
F to
131
°F (5
°C to
55°
C)
4.
Sto
rage
tem
pera
ture
: -13
°F to
185
°F (-
25°C
to 8
5°C
)
Ensuring The High AvailabilityOf Mission-Critical Data And Applications.
Emerson Network Power, the global leader in enabling business-criticalcontinuity, ensures network resiliency and adaptability througha family of technologies—including Liebert power and coolingtechnologies—that protect and support business-critical systems.Liebert solutions employ an adaptive architecture that respondsto changes in criticality, density and capacity. Enterprises benefitfrom greater IT system availability, operational flexibility andreduced capital equipment and operating costs.
While every precaution has been taken to ensure the accuracyand completeness of this literature, Liebert Corporation assumes noresponsibility and disclaims all liability for damages resulting from use ofthis information or for any errors or omissions.© 2009 Liebert CorporationAll rights reserved throughout the world. Specifications subject to changewithout notice.® Liebert is a registered trademark of Liebert Corporation.All names referred to are trademarksor registered trademarks of their respective owners.
Technical Support / ServiceWeb Site
www.liebert.comMonitoring
Outside North America: +00800 1155 4499Single-Phase UPS & Server Cabinets
Outside North America: +00800 1155 4499Three-Phase UPS & Power Systems
800-543-2378Outside North America: 614-841-6598
Environmental Systems800-543-2778
Outside the United States: 614-888-0246
LocationsUnited States
1050 Dearborn DriveP.O. Box 29186
Columbus, OH 43229Europe
Via Leonardo Da Vinci 8Zona Industriale Tognana
35028 Piove Di Sacco (PD) Italy+39 049 9719 111
Fax: +39 049 5841 257Asia
29/F, The Orient Square BuildingF. Ortigas Jr. Road, Ortigas Center
Pasig City 1605Philippines
+63 2 687 6615Fax: +63 2 730 9572
Emerson Network Power. The global leader in enabling Business-Critical Continuity™ EmersonNetworkPower.com
Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks of Emerson Electric Co. or one of its affiliated companies.©2010 Emerson Electric Co.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Infrastructure Management & Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
SL-20828_REV1_02-11