Maintenance Node Construction A30828-X1160-M-2-7620
Transcript

MaintenanceNode ConstructionA30828-X1160-M-2-7620

Construction

Maintenance Node

f

Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures. Non-observance of these conditions and the safety instructions can result in personal injury or in property damage. Therefore, only trained and qualified personnel may install and maintain the system. The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.

The same text in German: Wichtiger Hinweis zur Produktsicherheit In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Spannung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen. Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverletzungen und Sachschden fhren. Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet. Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.

Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.

Copyright (C) Siemens AG 2002.Issued by the Information and Communication Networks Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

2

A30828-X1160-M-2-7620

Maintenance Node

Construction

Reason for UpdateSummary: New Hardware F:LTGP(B) UI-LTGP, M:DEC480 Details: Chapter/Section 2.61...91 3.4.1 4.6.17 Reason for Update F:LTGP and F:STMI in R:LTGN F:LTGP(B) for UI-LTGP M:DEC480

Issue HistoryIssue Number 1 Date of issue Reason for Update

08/2002

A30828-X1160-M-2-7620

3

Construction

Maintenance Node

4

A30828-X1160-M-2-7620

Maintenance Node

Construction

This document consists of a total of 775 pages. All pages are issue 2.

Contents1 2 2.1 2.2 2.3 2.4 2.5 2.5.1 2.5.2 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.29 2.30 2.31 2.32 2.33 2.34 2.35 2.36 2.37 2.38 2.39 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:CCNP/SILTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:CP113A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:CP113B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:CP113C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CP113C with F:PIOP(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CP113C with F:PIOP(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:CP113E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DEVB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DEVD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUA Configuration ABAB or C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUA Configuration ABBB or C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DEDE or F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration GEGE or F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DEGE or F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration GEDE or F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DDDD / DDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration GGGG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DDD, GGG, DGG, DDG, GDD, GGD . . . . . . . . . . . R:DLUB Configuration GEIJ or L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration GJIJ / GJI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DEIJ or L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration IJDE or F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration IJGE or F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration IJGJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DDD(F) with FAN . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DED(F) with FAN . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DEG(F) with FAN . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration DEI(L) with FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration GED(F) with FAN . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration GEG(F) with FAN . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration IJD(F) with FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB Configuration GEG with FMX2S/SNUS/SMA1K . . . . . . . . . . . . . . R:DLUB Configuration GGF with FMX2S/SNUS/SMA1K . . . . . . . . . . . . . . R:DLUB Configuration GGG with FMX2S/SNUS/SMA1K . . . . . . . . . . . . . R:DLUG Configuration ABAB or C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:DLUA for DSU Configuration ABAB or C . . . . . . . . . . . . . . . . . . . . . . . . R:DLUA for DSU Configuration ABBB or C . . . . . . . . . . . . . . . . . . . . . . . . R:DLUA for DSU Configuration ABB-Modem . . . . . . . . . . . . . . . . . . . . . . . R:DLUB for DSU Configuration GEGE or F . . . . . . . . . . . . . . . . . . . . . . . . R:DLUB for DSU Configuration GE-Modem . . . . . . . . . . . . . . . . . . . . . . . . 19 22 25 26 27 28 28 30 32 34 38 39 41 42 44 46 48 50 52 53 55 57 59 61 63 65 67 68 70 72 74 76 78 80 81 83 85 87 89 90 92 94

A30828-X1160-M-2-7620

5

Construction

Maintenance Node

2.40 2.41 2.42 2.43 2.44 2.45 2.46 2.47 2.48 2.49 2.50 2.51 2.52 2.53 2.54 2.55 2.56 2.57 2.58 2.59 2.60 2.61 2.62 2.63 2.64 2.65 2.66 2.67 2.68 2.69 2.70 2.71 2.72 2.73 2.74 2.75 2.76 2.77 2.78 2.79 2.80 2.81 2.82 2.83 2.84 2.85 2.86

R:DSU/LTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 R:DSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 R:HTI/RTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 R:HTI/RTI with SDHI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 R:HTI/RTI with one F:LTGN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 R:HTI/RTI with SDHI and one F:LTGN . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 R:HTI/RTI with two F:LTGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 R:HTI/RTI with SDHI and two F:LTGN. . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 R:HTI/RTI with three F:LTGN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 R:HTI/RTI with SDHI and three F:LTGN . . . . . . . . . . . . . . . . . . . . . . . . . . 105 R:LTGB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 R:LTGC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 R:LTGC/CR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 R:LTGD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 R:LTGF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 R:LTGG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 R:LTGG with LTGH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 R:LTGM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 R:LTGM with DLUV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 R:LTGM with LTGG and DLUV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 R:LTGM with LTGG and LTGH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 R:LTGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 R:LTGN with LTGG or LTGH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 R:LTGN with F:SDHI and FAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 R:LTGN with F:SDHI without FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 R:LTGN with DLUV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 R:LTGN with DLUV and LTGG or LTGH . . . . . . . . . . . . . . . . . . . . . . . . . . 127 R:LTGN with TSG, cabling from above . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 R:LTGN with TSG, cabling from below . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 R:LTGN with TSG and MB/CCG, cabling from above . . . . . . . . . . . . . . . . 130 R:LTGN with TSG and MB/CCG, cabling from below . . . . . . . . . . . . . . . . 131 R:LTGN with SSG, cabling from above . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 R:LTGN with SSG, cabling from below . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 R:LTGN with SSG and MB/CCG, cabling from above . . . . . . . . . . . . . . . . 134 R:LTGN with SSG and MB/CCG, cabling from below . . . . . . . . . . . . . . . . 135 R:LTGN with MBD and CCGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 R:LTGN with MBD and SSG, cabling from above . . . . . . . . . . . . . . . . . . . 137 R:LTGN with MBD and SSG, cabling from below . . . . . . . . . . . . . . . . . . . 139 R:LTGN with MBD and TSG, cabling from above . . . . . . . . . . . . . . . . . . . 140 R:LTGN with MBD and TSG, cabling from below . . . . . . . . . . . . . . . . . . . 141 R:LTGN with MBD and SNMUX, cabling from above . . . . . . . . . . . . . . . . 142 R:LTGN with MBD and SNMUX, cabling from below. . . . . . . . . . . . . . . . . 144 R:LTGN with MBD and SNCARE, cabling from above . . . . . . . . . . . . . . . 145 R:LTGN with MBD and SNCARE, cabling from below. . . . . . . . . . . . . . . . 146 R:LTGN with SNMUX, without FAN, cabling from above. . . . . . . . . . . . . . 147 R:LTGN with SNMUX, without FAN, cabling from below . . . . . . . . . . . . . . 148 R:LTGN with SNMUX and FAN, cabling from above . . . . . . . . . . . . . . . . . 149

6

A30828-X1160-M-2-7620

Maintenance Node

Construction

2.87 2.88 2.89 2.90 2.91 2.92 2.93 2.94 2.95 2.96 2.97 2.98 2.99 2.100 2.101 2.102 2.103 2.103.1 2.103.2 2.103.3 2.103.4 2.104 2.105 2.105.1 2.105.2 2.105.3 2.105.4 2.106 2.106.1 2.106.2 2.106.3 2.106.4 2.107 2.108 2.109 2.110 2.111 2.112 2.113 2.114 2.115 2.116 2.117 2.118 2.119 2.120 2.121

R:LTGN with SNMUX and FAN, cabling from below . . . . . . . . . . . . . . . . R:LTGN with SNCARE, cabling from above . . . . . . . . . . . . . . . . . . . . . . . R:LTGN with SNCARE, cabling from below . . . . . . . . . . . . . . . . . . . . . . . R:LTGN with 4 SNMUX and FAN, cabling from above . . . . . . . . . . . . . . . R:LTGN with 4 SNMUX and FAN, cabling from below . . . . . . . . . . . . . . . R:STMI/LTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:STMI/LTG with DLUV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:STMI/LTG with SNMUX(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:STMI/LTG with SNMUX(A) and DLUV . . . . . . . . . . . . . . . . . . . . . . . . . R:STMI/LTG with SNMUX(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:STMI/LTG with SNMUX(B) and DLUV . . . . . . . . . . . . . . . . . . . . . . . . . R:STMI/LTG with TSG(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:STMI/LTG with TSG(B) and DLUV . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:MB/CCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:MB/CCG with FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:MBD/CCGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SE (-C2539-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SE (-C2539-X100). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SE (-C2539-X100) with Profibus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SE (-C2539-X600). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SILTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SSNC (basic rack). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SSNC (basic rack minimal configuration) . . . . . . . . . . . . . . . . . . . . . . . R:SSNC (basic rack maximal configuration with 1 SCE and ASN(E)) . . . R:SSNC (basic rack with 1 SCE and ASN(H)) . . . . . . . . . . . . . . . . . . . . . R:SSNC (basic rack with 2 SCE and ASN(H)) . . . . . . . . . . . . . . . . . . . . . R:SSNC (extension rack) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SSNC (extension rack with 1 SCE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SSNC (extension rack with 2 SCE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SSNC (extension rack with 3 SCE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SSNC (extension rack with 4 SCE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SN (with DCCXI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SN (with DCCCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SN(B) / SNMUX / LTGG (cabling from above) . . . . . . . . . . . . . . . . . . . R:SN(B) / SNMUX / LTGG (cabling from below) . . . . . . . . . . . . . . . . . . . R:SN(B) / SNCARE / LTGG (cabling from above) . . . . . . . . . . . . . . . . . . R:SN(B) / SNCARE / LTGG (cabling from below) . . . . . . . . . . . . . . . . . . R:SN(B)/LTGM (cabling from above) . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SN(B)/LTGM (cabling from below) . . . . . . . . . . . . . . . . . . . . . . . . . . . . R:SN(B)/LTGM/SNCARE (cabling from above) . . . . . . . . . . . . . . . . . . . . R:SN(B)/LTGM/SNCARE (cabling from below) . . . . . . . . . . . . . . . . . . . . R:SN(B)/LTGM/SNMUX (cabling from above) . . . . . . . . . . . . . . . . . . . . . R:SN(B)/LTGM/SNMUX (cabling from below) . . . . . . . . . . . . . . . . . . . . . R:SN(B)/MB/LTGM (cabling from above) . . . . . . . . . . . . . . . . . . . . . . . . . R:SN(B)/MB/LTGM (cabling from below) . . . . . . . . . . . . . . . . . . . . . . . . . R:SND/MBD/LTGM (with SNCARE, cabling from above). . . . . . . . . . . . .

150 151 152 153 154 155 157 159 161 163 164 166 168 170 171 172 173 173 174 176 177 178 180 180 181 182 183 185 185 186 187 188 189 190 191 192 193 194 195 197 199 201 203 205 207 209 211

A30828-X1160-M-2-7620

7

Construction

Maintenance Node

2.122 2.123 2.124 2.125 2.126 2.127 2.128 2.129 2.130 2.131 2.132 2.133 2.134 2.135 2.136 2.137 3 3.1 3.1.1 3.1.2 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6 3.2.7 3.2.8 3.2.9 3.2.10 3.2.11 3.2.12 3.2.13 3.2.14 3.2.15 3.3 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 3.3.7 3.3.8 3.3.9 3.3.10

R:SND/MBD/LTGM (with SNCARE, cabling from below) . . . . . . . . . . . . . 213 R:SND/MBD/LTGM (with SNMUX, cabling from above) . . . . . . . . . . . . . . 215 R:SND/MBD/LTGM (with SNMUX, cabling from below) . . . . . . . . . . . . . . 217 R:SND/SNMAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 R:SSG(B)/LTGG (cabling from above). . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 R:SSG(B)/LTGG (cabling from below) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 R:SSG(B)/LTGM (cabling from above) . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 R:SSG(B)/LTGM (cabling from below). . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 R:SSG(B)/MB/LTGM (cabling from above) . . . . . . . . . . . . . . . . . . . . . . . . 225 R:SSG(B)/MB/LTGM (cabling from below) . . . . . . . . . . . . . . . . . . . . . . . . 227 R:TSG(B)/LTGG (cabling from above). . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 R:TSG(B)/LTGG (cabling from below) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 R:TSG(B)/LTGM (cabling from above). . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 R:TSG(B)/LTGM (cabling from below) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 R:TSG(B)/MB/LTGM (cabling from above) . . . . . . . . . . . . . . . . . . . . . . . . 235 R:TSG(B)/MB/LTGM (cabling from below). . . . . . . . . . . . . . . . . . . . . . . . . 237 Module Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 F:CCS7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 F:CCNP(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 F:SILTD(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 F:CP113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 F:BIOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 F:BPCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 F:CMY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 F:DEV(E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 F:DEV(F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263 F:EIOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264 F:EPCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 F:IOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 F:MI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 F:PBC(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 F:PI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 F:PIOP(A). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 F:PIOP(B). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 F:P/IOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302 Profibus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 F:DLU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305 F:DLU(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307 F:DLU(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 F:DLU(C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 F:DLU(D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315 F:DLU(E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318 F:DLU(F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321 F:DLU(G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323 F:DLU(I) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326 F:DLU(J). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 F:DLU(L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331

8

A30828-X1160-M-2-7620

Maintenance Node

Construction

3.3.11 3.3.12 3.3.13 3.3.14 3.3.15 3.3.16 3.3.17 3.3.18 3.3.19 3.3.20 3.3.21 3.4 3.4.1 3.4.2 3.4.3 3.4.4 3.4.5 3.4.6 3.4.7 3.4.8 3.4.9 3.4.10 3.4.11 3.5 3.5.1 3.5.2 3.5.3 3.6 3.6.1 3.6.2 3.6.3 3.6.4 3.6.5 3.6.6 3.6.7 3.6.8 3.6.9 3.6.10 3.7 3.7.1 3.7.2 3.7.3 3.7.4 3.8 3.8.1 3.8.2 3.8.3

F:DLUG(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLUG(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLUG(C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLUV(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLU(A) for DSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLU(B) for DSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLU(C) for DSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLU(E) for DSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLU(F) for DSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:DLU(G) for DSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:MODEM(D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGM(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGG(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGH(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGF(A). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGB(A). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGC(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:CR(A). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:LTGD(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:CRES(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:MB/CCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:MB/CCG(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:MBD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:CCGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (basic frame) (module side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (basic frame) (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (basic frame) (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (extension frame) (module side) . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (extension frame 0) (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (extension frame 0) (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (extension frame 1) (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (extension frame 1) (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (extension frame 2) (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . F:RSU (extension frame 2) (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SDHI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SDHI4 (module side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SDHI2 (module side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SDHI (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SDHI (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SMSC(C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SMSC(C)-0 (module side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SMSC(C)-1 (module side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F:SMSC(C)-0 (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

332 336 338 340 341 344 347 349 352 354 356 357 359 372 381 385 395 396 401 408 410 411 413 415 415 429 445 451 451 452 452 454 454 455 456 456 457 457 459 459 459 460 460 462 462 462 463

A30828-X1160-M-2-7620

9

Construction

Maintenance Node

3.8.4 3.8.5 3.9 3.9.1 3.9.2 3.9.3 3.9.4 3.9.5 3.9.6 3.9.7 3.9.8 3.9.9 3.9.10 3.10 3.10.1 3.10.2 3.10.3 3.10.4 3.11 3.11.1 3.11.2 3.11.3 3.11.4 3.11.5 3.12 3.12.1 3.12.2 3.12.3 3.13 3.13.1 3.13.2 3.13.3 3.13.4 3.13.5 3.13.6 4 4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 4.1.7 4.2 4.2.1 4.2.2

F:SMSC(C)-1 (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463 F:SMSC(C) (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464 F:SN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469 F:SN(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470 F:SSG(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472 F:TSG(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479 F:DCC(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482 F:TSG(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482 F:SSG(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 487 F:SNMAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493 F:SNMUX(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 497 F:SNMUX(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503 F:SNCARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508 F:SSNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 F:SCB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 F:SCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 517 F:ASN(E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524 F:ASN(H) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 529 F:STMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 533 F:STMI (module side). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 533 LTU-Types for LTG in B operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534 LTU-Types for LTG in C operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 535 F:STMI (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 536 F:STMI (cabling). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 536 F:SYPC(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 539 F:SYPC(A) (module side). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 539 F:SYPC(A) (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 539 F:SYPC(A) (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 540 Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542 FAN (B5681) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542 FAN-BOX (B5877) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543 FAN-BOX (U102) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544 FANTRAY (U103) (U2620) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 545 FAN (U2623) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 546 FAN-BOX (U2624) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 548 CCG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 549 CCGES (-Q146-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 550 CCGED (-Q147-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 551 CCGB (-Q887-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 552 CCGXXA (-Q888-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 553 CDEX (-Q900-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559 CDEX (-Q900-X100-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 561 CDEX (-Q900-X200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 562 CCS7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563 MH:SIMP (-Q1017-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563 MUXMA (-Q1117-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563

10

A30828-X1160-M-2-7620

Maintenance Node

Construction

4.2.3 4.2.4 4.2.5 4.2.6 4.2.7 4.3 4.3.1 4.3.2 4.3.3 4.3.4 4.3.5 4.3.6 4.3.7 4.3.8 4.3.9 4.3.10 4.3.11 4.3.12 4.3.13 4.3.14 4.3.15 4.3.16 4.3.17 4.3.18 4.3.19 4.3.20 4.3.21 4.3.22 4.3.23 4.3.24 4.4 4.4.1 4.4.2 4.4.3 4.4.4 4.4.5 4.4.6 4.4.7 4.4.8 4.4.9 4.4.10 4.4.11 4.4.12 4.4.13 4.4.14 4.4.15 4.4.16

PMU:CPI (-Q1180-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PMU:SIMP (-Q1179-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SILTC (-Q766-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SILTD (-Q1023-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SIPA (-Q1016-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CP113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AMPC (-Q1388-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BCM (-Q1252-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BCTI (-Q946-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CMYE (-Q244-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CMY2C (-Q963-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CMYC (-Q1255-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CMYM (-Q1256-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CPCL (-Q933-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CPEX (-Q930-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF:MDD (-Q976-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IK:DTD (-Q975-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IOP:AUC (-Q1169-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IOP:MB (-Q954-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IOP:SCDV (-Q952-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IOP:TA (-Q956-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IOP:UNI (-Q1257-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LCUB (-Q1114-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LAUB (-Q1115-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PEX (-Q1251-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PEXE (-Q242-) (-Q243-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PIA (-Q1253-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PIDAT (-Q940-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MUH (-Q1088-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MTI (-Q1254-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCCA (-Q5619-A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCCB (-Q5619-B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCCC (-Q5619-C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCCK (-Q5619-K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCCL (-Q5619-L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCCR (-Q5619-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCCS (-Q5619-S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCCV (-Q5619-V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCDC (-Q5862-C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCDD (-Q5862-D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCDE (-Q5862-E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCDF (-Q5862-F). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCDK (-Q6104-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCDM (-Q6111-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCDQ (-Q6125-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCCDR (-Q6129-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

564 564 565 566 568 569 570 571 572 572 573 573 574 575 575 576 576 576 577 578 582 582 583 583 584 585 586 587 588 589 590 591 592 592 593 593 594 594 595 595 596 596 596 596 597 597 597

A30828-X1160-M-2-7620

11

Construction

Maintenance Node

4.4.17 4.4.18 4.4.19 4.4.20 4.4.21 4.4.22 4.4.23 4.4.24 4.5 4.5.1 4.5.2 4.5.3 4.5.4 4.5.5 4.5.6 4.5.7 4.5.8 4.5.9 4.5.10 4.5.11 4.5.12 4.5.13 4.5.14 4.5.15 4.5.16 4.5.17 4.5.18 4.5.19 4.5.20 4.5.21 4.5.22 4.5.23 4.5.24 4.5.25 4.5.26 4.5.27 4.5.28 4.5.29 4.5.30 4.5.31 4.5.32 4.5.33 4.5.34 4.5.35 4.5.36 4.5.37 4.5.38

DCCDU (-Q6131-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 597 DCCDW (-Q6133-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 598 DCCMC (-Q5883-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 598 DCCMD (-Q5897-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 598 DCCMR (-Q5619-R100). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 598 DCCMS (-Q5619-S100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599 DCCMS (-Q5897-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599 DCCXI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599 DLU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 BDB (-Q808-), (-Q1002-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602 BDCG (-Q809-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602 BDE (-Q807-), (-Q1003-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603 DIU:LDID (-Q1109-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603 DIUDA (-Q806-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604 DIUDC (-Q1007-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605 DLUC (-Q968-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 606 DLUC (-Q112-, -Q113-, Q114-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 607 DLUS (-Q1492-), (-Q1493-), (-Q1494-) . . . . . . . . . . . . . . . . . . . . . . . . . . . 608 DLUV (-Q1498-), (-Q126-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610 DSU modems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 611 EMSP (-Q1094-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 613 EMSP (-Q828-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 613 FMTU (-Q1112-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614 FMTU (-Q117-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614 FTEM (-Q957-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614 GCG (-Q1322-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615 IWEx (-Q144-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616 IWEx (-Q1177-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621 IWESx (-Q1178-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 622 LMEM (-Q811-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623 LVMM (-Q812-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623 LTCD (-Q124-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624 LTCD (-Q1495-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 625 LTOD (-Q1496-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 626 MGB (-Q1323-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 627 MTAM (-Q1066-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 628 OMX16D (-Q1497-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 629 RGB (-Q1324-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 630 RGMG (-Q813-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 631 RGMG (-Q895-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633 SASC (-Q1133-), (-Q22-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634 SASCG (-Q111-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634 SLMA (-Q1011-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635 SLMD (-Q838-), (-Q965-), (-Q1101-), (-Q1103-), (-Q1192-) . . . . . . . . . . . 635 SLMD (-Q210-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 636 SLMD (-Q52-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637 SLMI:AMA (-Q225-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637

12

A30828-X1160-M-2-7620

Maintenance Node

Construction

4.5.39 4.5.40 4.5.41 4.5.42 4.5.43 4.5.44 4.5.45 4.5.46 4.6 4.6.1 4.6.2 4.6.3 4.6.4 4.6.5 4.6.6 4.6.7 4.6.8 4.6.9 4.6.10 4.6.11 4.6.12 4.6.13 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18 4.6.19 4.6.20 4.6.21 4.6.22 4.6.23 4.6.24 4.6.25 4.6.26 4.6.27 4.6.28 4.6.29 4.6.30 4.6.31 4.6.32 4.6.33 4.6.34 4.6.35 4.6.36 4.6.37 4.6.38

SLMI:FMA (-Q164-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLMI:FMB (-Q200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLMI:MPB (-Q143-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLMI:PHA (-Q142-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLMI:PHA (-Q170-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLMI:PHB (-Q192-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLMI:SDA (-Q155-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLMX (-Q1338-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ATCO (-Q267-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ATE:TM (-Q969-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ATE:N (-Q94-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CGSM (-Q1185-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COUC (-Q31-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRM:R1 (-Q913-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRM8:R1 (-Q1105-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRM:R2 (-Q913-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRM8:R2 (-Q1105-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRM:SC (-Q913-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRPC (-Q264-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRPC (-Q913-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CRP8 (-Q1105-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCRCx (-Q743-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEC120 (-Q1467-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEC120 (-Q1467-X100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEC480 (-Q328-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DESA (-A162-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DESB_A1 (-B163-A1-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DESB_B1 (-B163-B1-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIU30A (-Q562-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIU30B (-Q563-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIU30D (-Q876-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIU30F (-Q876-X200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIU120A (-Q1346-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIU:LDIB (-Q1107-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIU:LDIM (-Q1343-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ETEAE (-Q670-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GCG:LTGY (-Q724-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPLC (-Q1349-X301-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPLD (-Q1349-X401-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPLSD (-Q1339-X401-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPLSE (-Q1339-X601-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPNLD (-Q28-X200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPNLE (-Q28-X600-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPNYC (-Q27-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPNYD (-Q27-X200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPNYE (-Q27-X600-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

638 638 639 640 641 642 643 643 644 646 647 648 649 649 650 651 651 652 652 653 654 655 655 655 656 658 659 659 660 661 662 663 664 665 665 666 666 669 669 670 670 671 672 673 674 675 675

A30828-X1160-M-2-7620

13

Construction

Maintenance Node

4.6.39 4.6.40 4.6.41 4.6.42 4.6.43 4.6.44 4.6.45 4.6.46 4.6.47 4.6.48 4.6.49 4.6.50 4.6.51 4.6.52 4.6.53 4.6.54 4.6.55 4.6.56 4.6.57 4.6.58 4.6.59 4.6.60 4.6.61 4.6.62 4.6.63 4.6.64 4.6.65 4.6.66 4.6.67 4.6.68 4.6.69 4.6.70 4.6.71 4.6.72 4.6.73 4.6.74 4.7 4.7.1 4.7.2 4.7.3 4.7.4 4.8 4.8.1 4.8.2 4.8.3 4.8.4 4.8.5

GPNZC (-Q26-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 676 GPNZD (-Q26-X200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 677 GPNZE (-Q26-X600-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 678 GPPYF (-Q277-X000 -) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 679 GPPYG (-Q277-X100 -) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 680 GPPYH (-Q277-X200 -) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681 GPPYI (-Q277-X300 -) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 682 GPPZF (-Q302-X000 -) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683 GPPZG (-Q302-X100 -) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684 GPPZH (-Q302-X200 -) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 685 GPPZI (-Q302-X300 -) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 686 GSM (-Q1340-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 686 MCAA (-Q729-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 686 MCT (-Q63-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687 MDTOG (-Q1105-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687 MDTOG (-Q1490-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688 OCE:MUPx (-Q1030-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688 OCE:SPC (-Q1031-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689 OCE:SPM (-Q1401-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689 OCE:N (-Q165-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 690 PHMA (-Q1469-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 690 PMUx (-Q1141-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691 PMUE (-Q1141-X600-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691 RM:CTC (-Q829-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 692 RM:CTC (-Q913-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 692 SCR (-Q1445-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 693 SILCB (-Q1110-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694 SILCD (-Q1110-X200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694 SILC:DLU (-Q783-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695 SILC:PA (-Q783-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695 TEM:COP (-Q606-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 696 TEM:LE (-Q607-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 699 TOGB (-Q738-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 699 TOGC (-Q1290-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 699 TOGD (-Q1291-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700 VPU (-Q190-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700 MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701 MBDA (-Q54-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701 MBDC (-Q55-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 702 MBDCG (-Q56-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 703 MBDH (-Q57-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 704 RSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705 AMUX (-Q104-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705 DIU240A (-Q106-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 706 DIU240B (-Q107-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 707 RSUC (-Q98-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708 MH (-Q97-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 709

14

A30828-X1160-M-2-7620

Maintenance Node

Construction

4.8.6 4.8.7 4.9 4.9.1 4.9.2 4.10 4.10.1 4.10.2 4.10.3 4.10.4 4.10.5 4.10.6 4.10.7 4.11 4.11.1 4.11.2 4.11.3 4.11.4 4.11.5 4.11.6 4.11.7 4.12 4.12.1 4.12.2 4.12.3 4.12.4 4.12.5 4.12.6 4.12.7 4.12.8 4.12.9 4.12.10 4.12.11 4.12.12 4.12.13 4.12.14 4.12.15 4.13 4.13.1 4.13.2 4.13.3 4.13.4 4.13.5 4.13.6 4.13.7 4.13.8 4.14

TSIMA (-Q105-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TSIMB (-Q105-X100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SDHI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OIM*W (-D3559-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OIM*P (-D3560-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCGB (-Q887-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCGXXA (-Q888-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CDEX (-Q900-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CDEX (-Q900-X100-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PU:SYCR (-Q867-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T/RM:SYCR (-Q868-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T/RM:SYCR (-Q868-X200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LILD (-Q70-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LILE (-Q263-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MATC (-Q73-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MATM (-Q72-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MUXC (-Q71-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFC (-Q264-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SNOPT (-Q280-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SSNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACCG (Q145) (Q1022) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ALIB (Q1065) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AMXE (Q1019) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASMG16/16 (Q1034) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GMX:E (Q1032) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LIC:2A (Q1014). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LIC:1,5A (Q1013) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MDD (U2594) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOD (Q1028) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPUC (SA,512MB)(Q82-X401) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPUC (AP,512MB)(Q80-X401) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPUC (equipment side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPUD (Q83) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPUD (Q85-X801) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PSAG (Q6124) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPSF (-Q278-X000-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPSG (-Q278-X100-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPSH (-Q278-X200-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GPSI (-Q278-X300-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STMI:E(W) (-Q300-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STMI:E(P) (-Q301-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STMI:O(W) (-Q298-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STMI:O(P) (-Q299-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SYP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

710 711 712 712 713 714 714 714 714 714 714 714 719 725 725 726 727 727 728 728 729 730 730 732 732 733 733 734 735 736 736 737 737 738 738 739 739 740 740 741 742 743 744 745 746 747 748

A30828-X1160-M-2-7620

15

Construction

Maintenance Node

4.14.1 4.14.2 4.14.3 4.14.4 4.14.5 4.14.6 4.14.7 4.14.8 4.14.9 4.14.10 4.14.11 4.14.12 4.14.13

COM:SYPC (-Q758-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 748 RM:EA (-Q760-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 749 T/RM:SYPC (-Q761-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750 T/RM:SYPC (-Q761-X100-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 751 TXA:SYPC (-Q759-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 752 ACC:SYPD (-Q776-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756 DYM:SYPD (-Q708-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757 EWA:SYPD (-Q5517-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759 T/RM:SYPD (-Q709-X-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 760 T/RM:SYPD (-Q709-X100-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 760 PBSL32J (-U2607-). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762 PBSL8RO (-U2608-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 766 PBSLV24 (-U2609-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 770

16

A30828-X1160-M-2-7620

Maintenance Node

Construction

1 IntroductionThe construction manual contains all the hardware components of a network node that are relevant for fault clearance using maintenance and nonstandard manuals. The construction manual is divided into the following sections: Racks (division, layout of fuse panel) Module Frames (module side, backplane, cabling) Modules (faceplate, component side, switch settings, displays)

A30828-X1160-M-2-7620

17

Construction

Maintenance Node

18

A30828-X1160-M-2-7620

Maintenance Node

Construction

2 Racks2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.29 2.30 2.31 2.32 2.33 2.34 2.35 2.36 2.37 2.38 2.39 2.40 2.41 2.42 2.43 2.44 2.45 R:CE R:CCNP/SILTD R:CP113A R:CP113B R:CP113C R:CP113E R:DEVB R:DEVD R:DLUA Configuration ABAB or C R:DLUA Configuration ABBB or C R:DLUB Configuration DEDE or F R:DLUB Configuration GEGE or F R:DLUB Configuration DEGE or F R:DLUB Configuration GEDE or F R:DLUB Configuration DDDD / DDD R:DLUB Configuration GGGG R:DLUB Configuration DDD, GGG, DGG, DDG, GDD, GGD R:DLUB Configuration GEIJ or L R:DLUB Configuration GJIJ / GJI R:DLUB Configuration DEIJ or L R:DLUB Configuration IJDE or F R:DLUB Configuration IJGE or F R:DLUB Configuration IJGJ R:DLUB Configuration DDD(F) with FAN R:DLUB Configuration DED(F) with FAN R:DLUB Configuration DEG(F) with FAN R:DLUB Configuration DEI(L) with FAN R:DLUB Configuration GED(F) with FAN R:DLUB Configuration GEG(F) with FAN R:DLUB Configuration IJD(F) with FAN R:DLUB Configuration GEG with FMX2S/SNUS/SMA1K R:DLUB Configuration GGF with FMX2S/SNUS/SMA1K R:DLUB Configuration GGG with FMX2S/SNUS/SMA1K R:DLUG Configuration ABAB or C R:DLUA for DSU Configuration ABAB or C R:DLUA for DSU Configuration ABBB or C R:DLUA for DSU Configuration ABB-Modem R:DLUB for DSU Configuration GEGE or F R:DLUB for DSU Configuration GE-Modem R:DSU/LTG R:DSM R:HTI/RTI R:HTI/RTI with SDHI R:HTI/RTI with one F:LTGN R:HTI/RTI with SDHI and one F:LTGN

A30828-X1160-M-2-7620

19

Construction

Maintenance Node

2.46 2.47 2.48 2.49 2.50 2.51 2.52 2.53 2.54 2.55 2.56 2.57 2.58 2.59 2.60 2.61 2.62 2.63 2.64 2.65 2.66 2.67 2.68 2.69 2.70 2.71 2.72 2.73 2.74 2.75 2.76 2.77 2.78 2.79 2.80 2.81 2.82 2.83 2.84 2.85 2.86 2.87 2.88 2.89 2.90 2.91 2.92

R:HTI/RTI with two F:LTGN R:HTI/RTI with SDHI and two F:LTGN R:HTI/RTI with three F:LTGN R:HTI/RTI with SDHI and three F:LTGN R:LTGB R:LTGC R:LTGC/CR R:LTGD R:LTGF R:LTGG R:LTGG with LTGH R:LTGM R:LTGM with DLUV R:LTGM with LTGG and DLUV R:LTGM with LTGG and LTGH R:LTGN R:LTGN with LTGG or LTGH R:LTGN with F:SDHI and FAN R:LTGN with F:SDHI without FAN R:LTGN with DLUV R:LTGN with DLUV and LTGG or LTGH R:LTGN with TSG, cabling from above R:LTGN with TSG, cabling from below R:LTGN with TSG and MB/CCG, cabling from above R:LTGN with TSG and MB/CCG, cabling from below R:LTGN with SSG, cabling from above R:LTGN with SSG, cabling from below R:LTGN with SSG and MB/CCG, cabling from above R:LTGN with SSG and MB/CCG, cabling from below R:LTGN with MBD and CCGE R:LTGN with MBD and SSG, cabling from above R:LTGN with MBD and SSG, cabling from below R:LTGN with MBD and TSG, cabling from above R:LTGN with MBD and TSG, cabling from below R:LTGN with MBD and SNMUX, cabling from above R:LTGN with MBD and SNMUX, cabling from below R:LTGN with MBD and SNCARE, cabling from above R:LTGN with MBD and SNCARE, cabling from below R:LTGN with SNMUX, without FAN, cabling from above R:LTGN with SNMUX, without FAN, cabling from above R:LTGN with SNMUX and FAN, cabling from above R:LTGN with SNMUX and FAN, cabling from below R:LTGN with SNCARE, cabling from above R:LTGN with SNCARE, cabling from below R:LTGN with 4 SNMUX and FAN, cabling from above R:LTGN with 4 SNMUX and FAN, cabling from below R:STMI/LTG

20

A30828-X1160-M-2-7620

Maintenance Node

Construction

2.93 2.94 2.95 2.96 2.97 2.98 2.99 2.100 2.101 2.102 2.103 2.104 2.105 2.106 2.107 2.108 2.109 2.110 2.111 2.112 2.113 2.114 2.115 2.116 2.117 2.118 2.119 2.120 2.121 2.122 2.123 2.124 2.125 2.126 2.127 2.128 2.129 2.130 2.131 2.132 2.133 2.134 2.135 2.136 2.137

R:STMI/LTG with DLUV R:STMI/LTG with SNMUX(A) R:STMI/LTG with SNMUX(A) and DLUV R:STMI/LTG with SNMUX(B) R:STMI/LTG with SNMUX(B) and DLUV R:STMI/LTG with TSG(B) R:STMI/LTG with TSG(B) and DLUV R:MB/CCG R:MB/CCG with FAN R:MBD/CCGE R:SE R:SILTD R:SSNC (basic rack) R:SSNC (extension rack) R:SN (with DCCXI) R:SN (with DCCCS) R:SN(B) / SNMUX / LTGG (cabling from above) R:SN(B) / SNMUX / LTGG (cabling from below) R:SN(B) / SNCARE / LTGG (cabling from above) R:SN(B) / SNCARE / LTGG (cabling from below) R:SN(B)/LTGM (cabling from above) R:SN(B)/LTGM (cabling from below) R:SN(B)/LTGM/SNCARE (cabling from above) R:SN(B)/LTGM/SNCARE (cabling from below) R:SN(B)/LTGM/SNMUX (cabling from above) R:SN(B)/LTGM/SNMUX (cabling from below) R:SN(B)/MB/LTGM (cabling from above) R:SN(B)/MB/LTGM (cabling from below) R:SND/MBD/LTGM (with SNCARE, cabling from above) R:SND/MBD/LTGM (with SNCARE, cabling from below) R:SND/MBD/LTGM (with SNMUX, cabling from above) R:SND/MBD/LTGM (with SNMUX, cabling from below) R:SND/SNMAT R:SSG(B)/LTGG (cabling from above) R:SSG(B)/LTGG (cabling from below) R:SSG(B)/LTGM (cabling from above) R:SSG(B)/LTGM (cabling from below) R:SSG(B)/MB/LTGM (cabling from above) R:SSG(B)/MB/LTGM (cabling from below) R:TSG(B)/LTGG (cabling from above) R:TSG(B)/LTGG (cabling from below) R:TSG(B)/LTGM (cabling from above) R:TSG(B)/LTGM (cabling from below) R:TSG(B)/MB/LTGM (cabling from above) R:TSG(B)/MB/LTGM (cabling from below)

A30828-X1160-M-2-7620

21

Construction

Maintenance Node

2.1

R:CEFuse Panel 8 ft. rack FU 01 03 05 07 09 11 13 15 17 19 21 23 25 27 29 31 33 FU

FU

02 04 06 08 10 12 14 16 18 20 22 24 26 28 30

32

FU

Fuse Panel 7 ft. rack FU 01 03 05 07 09 11 13 15 17 19 21 23 25 27 29 31 33 FU

FU

02 04 06 08 10 12 14 16 18 20 22 24 26 28 30

32

FU

Fuse Panel F:SMSC(C) 0

MUT01 MUT02 Fuse Panel MUT01 MUT02

F:SMSC(C) 1 F:PIOP(A) 0 or F:PIOP(B) 0 FAN (B5681) F:PBC(A) 0

MUT04 F:SMSC(C) 0 MUT03 F:SMSC(C) 1 MUT08 MUT05 FAN (B5681) F:PIOP(A) 0 or F:PIOP(B) 0 F:PBC(A) 0 MUT09 MUT07 F:PBC(A) 0 F:PIOP(A) 1 or F:PIOP(B) 1 FAN-BOX (B5877) rack 7 ft.

MUT04 MUT08 MUT03

F:PBC(A) 1 FAN (B5681) F:PIOP(A) 1 or F:PIOP(B) 1 F:DEV(F)) 1 FAN-BOX (B5877)

MUT06

MUT05

MUT06

MUT10

MUT07 MUT11

MUT11

rack 8 ft.

FU 02 04 06 08

MUT MUT02 MUT02 MUT02 MUT02

Unit F:SMSC(C) - 0 F:SMSC(C) - 0 F:SMSC(C) - 0 F:SMSC(C) - 0 C101 / DCC for SYCR C153/ DCC for CCG 0 SYPD 0 / SYPD 1 C259 / DCC for MB 0

MOLOC

Tab. 2.1

Fuse Assignment R:CE without SSNC connection to

22

A30828-X1160-M-2-7620

Maintenance Node

Construction

FU 10 11 23 25 27 29 03 05 07 09 12 13 14 15 16 17 18 19 20 21 22 32 24 26 28 30 01 33 31

MUT MUT02 MUT02 MUT04 MUT04 MUT04 MUT04 MUT03 MUT03 MUT03 MUT03 MUT08 MUT05 MUT05 MUT05 MUT05 MUT05 MUT06 MUT06 MUT06 MUT06 MUT06 MUT09 MUT07 MUT07 MUT07 MUT07 MUT10 MUT10 MUT11

Unit F:SMSC(C) - 0 F:SMSC(C) - 0 F:SMSC(C) - 1 F:SMSC(C) - 1 F:SMSC(C) - 1 F:SMSC(C) - 1 F:PIOP(A) - 0 F:PIOP(A) - 0 F:PIOP(A) - 0 F:PIOP(A) - 0 FAN F:PBC(A) - 0 F:PBC(A) - 0 F:PBC(A) - 0 F:PBC(A) - 0 F:PBC(A) - 0 F:PBC(A) - 1 F:PBC(A) - 1 F:PBC(A) - 1 F:PBC(A) - 1 F:PBC(A) - 1 FAN F:PIOP(A) - 1 F:PIOP(A) - 1 F:PIOP(A) - 1 F:PIOP(A) - 1 F:DEV(F) *) F:DEV(F) FAN-BOX

MOLOC C343P1 / DCC for SN0 external horn/ external alarm C101 / DCC for CDEX C153 / DCC for CCG1 C259 / DCC MB1 C343P1 / DCC for SN1 C101P1 / free for CAP C127P1 / DCC for IOC 0 C249P1 / On-board converter from M:LAUB C337P1 / DCC for M:IOPG 0

C101P1 / DCC for BAP 0 C125P1 / free C151P1 / DCC for M:BCMY 0 C159P1 / On-board converter from M:BCM 0 C339P1 / DCC for M:CMY 0 C101P1 / DCC for BAP1 C125P1 / free C151P1 / DCC for M:BCMY1 C159P1 / On-board converter from M:BCM1 C339P1 / DCC for M:CMY1 optional C101P1 / free for CAP C127P1 / DCC for IOC1 C249P1 / On-board converter from M:LAUB C337P1 / DCC for IOPG 1 MDD 0 / MOD 0 only in 8 ft-rack MDD 1 / MOD 1 only in 8 ft-rack

Tab. 2.1

Fuse Assignment R:CE without SSNC connection to

FU 02 04 06 08 10

MUT MUT02 MUT02 MUT02 MUT02 MUT02

Unit F:SMSC(C) - 0 F:SMSC(C) - 0 F:SMSC(C) - 0 F:SMSC(C) - 0 F:SMSC(C) - 0 C101 / DCC for SYCR

MOLOC

C153 / DCC for CCG 0 SYPD 0 / SYPD 1 C259 / DCC for MB 0 C343P1 / DCC for SN 0

Tab. 2.2

Fuse Assignment R:CE with SSNC connection to

A30828-X1160-M-2-7620

23

Construction

Maintenance Node

FU 11 23 25 27 29 03 05 07 09 12 13 14 15 16 17 18 19 20 21 22 32 24 26 28 30 01 33 31

MUT MUT02 MUT04 MUT04 MUT04 MUT04 MUT03 MUT03 MUT03 MUT03 MUT08 MUT05 MUT05 MUT05 MUT05 MUT05 MUT06 MUT06 MUT06 MUT06 MUT06 MUT09 MUT07 MUT07 MUT07 MUT07 MUT10 MUT10 MUT11

Unit F:SMSC(C) - 0 F:SMSC(C) - 1 F:SMSC(C) - 1 F:SMSC(C) - 1 F:SMSC(C) - 1 F:PIOP(B) - 0 F:PIOP(B) - 0 F:PIOP(B) - 0 F:PIOP(B) - 0 FAN F:PBC(A) - 0 F:PBC(A) - 0 F:PBC(A) - 0 F:PBC(A) - 0 F:PBC(A) - 0 F:PBC(A) - 1 F:PBC(A) - 1 F:PBC(A) - 1 F:PBC(A) - 1 F:PBC(A) - 1 FAN F:PIOP(B) - 1 F:PIOP(B) - 1 F:PIOP(B) - 1 F:PIOP(B) - 1 F:DEV(F) *) F:DEV(F) FAN-BOX

MOLOC external horn/ external alarm C101 / DCC for CDEX C153 / DCC for CCG 1 C259 / DCC for MB 1 C343 / DCC for SN 1 C101P1 / DCC for CAP4 C131P1 / free for IOC C257P5 / M:LAUB (all) for On-board converter C341P1 / DCC for M:IOPG 0 and DCC for IOP 0

C101P1 / DCC for BAP 0 C125P1 / free for IOC 0 C151P1 / DCC for M:BCMY 0 C159P1 / On-board converter from M:BCM 0 C339P1 / DCC for M:CMY 0 C101P1 / DCC for BAP1 C125P1 / free for IOC C151P1 / DCC for M:BCMY 1 C159P1 / On-board converter from M:BCM C339P1 / DCC for M:CMY1 optional C101P1 / DCC for CAP3 C131P1 / free for IOC C257P5 / On-board converter from M:LAUB C341P1 / DCC for IOPG 1 and DCC for IOC 1 MDD 0 / MOD 0 only in 8 ft-rack MDD 1 / MOD 1 only in 8 ft-rack

Tab. 2.2

Fuse Assignment R:CE with SSNC connection to

24

A30828-X1160-M-2-7620

Maintenance Node

Construction

2.2

R:CCNP/SILTDFuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel F:SILTD(A)

MUT01 MUT02 Fuse Panel MUT01

F:SILTD(A)

MUT04

F:SILTD(A)

MUT02

F:SILTD(A)

MUT06 F:SILTD(A) MUT04

F:SILTD(A)

MUT06

F:CCNP(B)

MUT08

F:CCNP(B)

MUT08

F:CCNP(B)

MUT10

F:CCNP(B)

MUT10

rack 8 ft.

rack 7 ft.

FU 01 11 03 13 07 17 05 06 15 16

MUT MUT02 MUT02 MUT04 MUT04 MUT06 MUT06 MUT08 MUT08 MUT10 MUT10 F:SILTD 0 F:SILTD 0 F:SILTD 1 F:SILTD 1 F:SILTD 2 F:SILTD 2

Unit A001 A120 A001 A120 A001 A120 A001 MUXM A120 CCNP A001 MUXM A120 CCNP

MOLOC

F:CCNP(B) 0 F:CCNP(B) 0 F:CCNP(B) 1 F:CCNP(B) 1

Tab. 2.3

Fuse Assignment R:CCNP/ SILTD

A30828-X1160-M-2-7620

25

Construction

Maintenance Node

2.3

R:CP113AFuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel

MUT01 MUT03 Fuse Panel MUT01 MUT03

F:CMY 0

F:CMY 1 FAN (B5681) F:MI 0

MUT04 MUT05

F:CMY 0

F:CMY 1 MUT06 FAN (B5681) F:MI 1 MUT07 F:MI 0

MUT04 MUT05 MUT06

F:MI 1 F:P/IOC MUT09

MUT07

F:P/IOC

MUT09

F:P/IOC

MUT10

F:P/IOC FAN-BOX (B5877) rack 7 ft.

MUT10

FAN-BOX (B5877) rack 8 ft.

MUT12

MUT12

FU 02 12 07 04 14 05 06 15 16 17 19 20

MUT MUT03 MUT04 MUT05 MUT06 MUT07 MUT09 MUT09 MUT10 MUT10 MUT12 MUT01 MUT01

Unit F:CMY 0 F:CMY 1 FAN F:MI 0 F:MI 1 F:P/IOC 0 F:P/IOC 0 F:P/IOC 1 F:P/IOC 1 FAN- BOX AD:RAL AD:RAL

MOLOC C101 / DCC for M:MUH and C327/ DCC for M:CMY 0 of the BCMY 0 C101 / DCC for M:MUH and C327/ DCC for M:CMY 1 of the BCMY 1 AIC1 C101 / DCC for PI and C327 / DCC for MI C101 / DCC for PI and C327 / DCC for MI C101 / DCC for BAP 0 C327 / DCC for IOC 0 C101 / DCC for BAP 1 C327 / DCC for IOC 1 AIC 0 AB-

Tab. 2.4

Fuse Assignment R:CP113A

26

A30828-X1160-M-2-7620

Maintenance Node

Construction

2.4

R:CP113BFuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel F:P/IOC 2

MUT01 MUT03 Fuse Panel MUT01 MUT03

F:P/IOC 3

MUT04 MUT05

F:P/IOC 2

FAN (B5681) F:PI 0

F:P/IOC 3 MUT06 FAN (B5681) F:PI 1 MUT07 F:PI 0

MUT04 MUT05 MUT06

F:PI 1 F:P/IOC 4 MUT09

MUT07

F:P/IOC 4

MUT08

F:P/IOC 5

MUT10

F:P/IOC 5 FAN-BOX (B5877) rack 7 ft.

MUT10 MUT12

FAN-BOX (B5877)

MUT12

rack 8 ft.

FU 01 02 11 12 07 03 13 05 06 15 16 17

MUT MUT03 MUT03 MUT04 MUT04 MUT05 MUT06 MUT07 MUT09 MUT09 MUT10 MUT10 MUT12

Unit F:P/IOC 2 F:P/IOC 2 F:P/IOC 3 F:P/IOC 3 FAN F:PI 0 F:PI 1 F:P/IOC 4 F:P/IOC 4 F:P/IOC 5 F:P/IOC 5 FAN- BOX C101 / DCC for CAP 0 C327 / DCC for IOC 2 C101 / DCC for CAP 1 C327 / DCC for IOC 3 AIC 17 C101 / DCC for BCMY 0 C101 / DCC for BCMY 1 C101 / DCC for CAP 2 C327 / DCC for CAP 3 C101 / DCC for CAP 4 C327 / DCC for CAP5 AIC 16

MOLOC

Tab. 2.5

Fuse Assignment R:CP113B

A30828-X1160-M-2-7620

27

Construction

Maintenance Node

FU 19 20

MUT MUT01 MUT01 AD:RAL AD:RA

Unit AB-

MOLOC

Tab. 2.5

Fuse Assignment R:CP113B

2.52.5.1

R:CP113CCP113C with F:PIOP(A)Fuse Panel 8 ft. rack FU 01 03 05 07 09 11 13 15 17 19 21 23 25 27 29 31 33 FU

FU

02 04 06 08 10 12 14 16 18 20 22 24 26 28 30

32

FU

Fuse Panel 7 ft. rack FU 01 03 05 07 09 11 13 15 17 19 21 23 25 27 29 31 33 FU

FU

02 04 06 08 10 12 14 16 18 20 22 24 26 28 30

32

FU

Fuse Panel F:PIOP(A) 2

MUT01 MUT02 Fuse Panel F:PIOP(A) 2 MUT01 MUT02

F:PIOP(A) 0 FAN (B5681) F:PBC(A) 0

MUT03 MUT04 MUT05

F:PIOP(A) 0 FAN (B5681) F:PBC(A) 0

MUT03 MUT04 MUT05

F:PBC(A) 1

MUT06

F:PIOP(A) 1 FAN (B5681) F:PIOP(A) 3

MUT07 MUT08 MUT09 F:PBC(A) 1 MUT06

F:PIOP(A) 1

MUT07

F:DEV(F) or F:DEV(E) FAN-BOX (B5877)

MUT10

F:PIOP(A) 3 FAN-BOX (B5877) rack 7 ft.

MUT09 MUT11

MUT11

rack 8 ft.

28

A30828-X1160-M-2-7620

Maintenance Node

Construction

FU 02 04 06 08 03 05 07 09 12 13 14 15 16 17 18 19 20 21 22 23 25 27 29 32 24 26 28 30 01 33 31

MUT MUT02 MUT02 MUT02 MUT02 MUT03 MUT03 MUT03 MUT03 MUT04 MUT05 MUT05 MUT05 MUT05 MUT05 MUT06 MUT06 MUT06 MUT06 MUT06 MUT07 MUT07 MUT07 MUT07 MUT08 MUT09 MUT09 MUT09 MUT09 MUT10 MUT10 MUT11

Unit F:PIOP(A) 2 F:PIOP(A) 2 F:PIOP(A) 2 F:PIOP(A) 2 F:PIOP(A) 0 F:PIOP(A) 0 F:PIOP(A) 0 F:PIOP(A) 0 FAN F:PBC 0 F:PBC 0 F:PBC 0 F:PBC 0 F:PBC 0 F:PBC 1 F:PBC 1 F:PBC 1 F:PBC 1 F:PBC 1 F:PIOP(A) 1 F:PIOP(A) 1 F:PIOP(A) 1 F:PIOP(A) 1 FAN F:PIOP(A) 3 F:PIOP(A) 3 F:PIOP(A) 3 F:PIOP(A) 3 F:DEV(F) or DEV(E) F:DEV(F) or DEV(E) FAN-BOX

MOLOC C101P1 / DCC for CAP 4 (Proc.10) C127P1 / DCC for IOC 2 (Proc. 5) C249P1 / On-board converter from M:LAUB (all) C337P1 DCC for IOPs C101P1 / DCC for CAP 2 (Proc. 8) C127P1 / DCC for IOC 0 (Proc.1) C249P1 /On-board converter from M:LAUB (all) C337P1 DCC for IOPs F2 / F1 C101P1 / DCC for BAP 0 (Proc. 0) C125P1 / DCC for CAP 0 (Proc. 4) C151P1 / DCC for BCMY 0 C159P1 / On-board converter of the M:BCM 0 C339P1 / DCC for CMY 0 C101P1 / DCC for BAP 1 (Proc. 2) C125P1 / DCC for CAP 1 (Proc. 6) C151P1 / DCC for BCMY 1 C159P1 / On-board converter of the M:BCM 1 C339P1 / DCC for CMY 1 C101P1 / DCC for CAP 3 (Proc. 9) C127P1 / DCC for IOC 1 (Proc. 3) C249P1 / On-board converter from M:LAUB (all) C337P1 / DCC for IOPs F2 / F1 (optional) C101P1 / DCC for CAP 5 (Proc.11) C127P1 / DCC for IOC 3 (Proc. 7) C249P1 / On-board converter from M:LAUB (all) C337P1 / DCC for IOPs MDD 0 / MOD 0 MDD 1 / MOD 1 X21 / X22

Tab. 2.6

Fuse Assignment R:CP113C with F:PIOP(A)

A30828-X1160-M-2-7620

29

Construction

Maintenance Node

2.5.2

CP113C with F:PIOP(B)Fuse Panel 8 ft. rack FU 01 03 05 07 09 11 13 15 17 19 21 23 25 27 29 31 33 FU

FU

02 04 06 08 10 12 14 16 18 20 22 24 26 28 30

32

FU

Fuse Panel 7 ft. rack FU 01 03 05 07 09 11 13 15 17 19 21 23 25 27 29 31 33 FU

FU

02 04 06 08 10 12 14 16 18 20 22 24 26 28 30

32

FU

Fuse Panel F:PIOP(B) 2

MUT01 MUT02 Fuse Panel F:PIOP(B) 2 MUT04 MUT05 F:PIOP(B) F:PIOP(A) 0 FAN (B5681) F:PBC(A) 0 MUT01 MUT02

F:PIOP(B) 0 FAN (B5681) F:PBC(A) 0

MUT03

MUT03 MUT04 MUT05

F:PBC(A) 1

MUT06

F:PIOP(B) 1 FAN (B5681) F:PIOP(B) 3

MUT07 MUT08 MUT09 F:PBC(A) 1 MUT06

F:PIOP(B) 1

MUT07

F:DEV(F) or F:DEV(E) FAN-BOX (B5877) rack 8 ft.

MUT10

F:PIOP(B) 3 FAN-BOX (B5877) rack 7 ft.

MUT09 MUT11

MUT11

FU 02 04 06 08 03

MUT MUT02 MUT02 MUT02 MUT02 MUT03

Unit F:PIOP(B) 2 F:PIOP(B) 2 F:PIOP(B) 2 F:PIOP(B) 2 F:PIOP(B) 0

MOLOC C101P1 C131P1 C257P5 C341P1 C101P1

CLASSIC DCC for CAP 4 (Proc. 10) DCC for CAP 8 (Proc. 14) M:LAUB DCC for IOPs / IOC2 (Proc. 5) DCC for CAP 2 (Proc. 8)

INNOVATION DCC for CAP 4 (Proc. 10) DCC for CAP 6 (Proc. 14) M:LAUB CAP 8 or IOC 2 (Proc.5) AMP0 (Proc. 8)

Tab. 2.7

Fuse Assignment R:CP113C with F:PIOP(B)

30

A30828-X1160-M-2-7620

Maintenance Node

Construction

FU 05 07 09 12 13 14 15 16 17 18 19 20 21 22 23 25 27 29 32 24 26 28 30 01 33 31

MUT MUT03 MUT03 MUT03 MUT04 MUT05 MUT05 MUT05 MUT05 MUT05 MUT06 MUT06 MUT06 MUT06 MUT06 MUT07 MUT07 MUT07 MUT07 MUT08 MUT09 MUT09 MUT09 MUT09 MUT10 MUT10 MUT11

Unit F:PIOP(B) 0 F:PIOP(B) 0 F:PIOP(B) 0 FAN F:PBC 0 F:PBC 0 F:PBC 0 F:PBC 0 F:PBC 0 F:PBC 1 F:PBC 1 F:PBC 1 F:PBC 1 F:PBC 1 F:PIOP(B) 1 F:PIOP(B) 1 F:PIOP(B) 1 F:PIOP(B) 1 FAN F:PIOP(B) 3 F:PIOP(B) 3 F:PIOP(B) 3 F:PIOP(B) 3 F:DEV(F) DEV(E) FAN- BOX

MOLOC C131P1 C257P5 C341P1 F2 / F1 C101P1 C125P1 C151P1 C159P1 C339P1 C101P1 C125P1 C151P1 C159P1 C339P1 C101P1 C131P1 C257P5 C341P11 F2 / F1 C101P1 C131P1 C257P5 C341P1 BAP 0 CAP 0 BCMY 0 BCM 0 CMY 0 BAP 1 CAP 1 BCMY 1 BCM 1 CMY 1

CLASSIC DCC for CAP 6 (Proc. 12) M:LAUB DCC for IOPs / OC0 (Proc. 1)

INNOVATION DCC for CAP 2 (Proc. 12) M:LAUB IOC 0 / IOP 0 (Proc. 1)

BAP 0 CAP 0 BCMY 0 BCM 0 CMY 0 BAP 1 CAP 1 BCMY 1 BCM 1 CMY 1 AMP 1 (Proc. 9) DCC for CAP 3(Proc. 13) M:LAUB DCC for IOPs

DCC for CAP 3 (Proc. 9) DCC for CAP 7 (Proc. 13) M:LAUB DCC for IOPs (Proc. 3)

DCC for CAP 5 (Proc. 11) DCC for CAP 9 (Proc. 15) M:LAUB DCC for IOPs (Proc. 7) MDD 0 / MOD 0 MDD 1/ MOD 1

DCC for CAP 5 (Proc. 11) DCC for CAP 7 (Proc.15) M:LAUB CAP 9 or IOC 3 (Proc. 7)

X22/X21

Tab. 2.7

Fuse Assignment R:CP113C with F:PIOP(B)

A30828-X1160-M-2-7620

31

Construction

Maintenance Node

2.6

R:CP113EFuse PanelON OFF 01 02 03 04 05 06 07 08 09 10 11 12 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 ON OFF

Fuse Panel

MUT01

Fuse Panel

MUT01

F:EIOP

MUT03

F:EIOP

MUT03

F:EIOP

MUT04

F:EIOP

MUT04

F:BIOP FANTRAY (U103) (U2620)

MUT05 MUT06 MUT07

F:BIOP FANTRAY (U103) (U2620)

MUT05 MUT06

F:BPCE

F:BPCE

MUT07

F:EPCE

MUT08

F:EPCE

MUT08

FAN-BOX (U102)

MUT10

FAN-BOX (U102)

MUT10

rack 8 ft.

rack 7 ft.

FU 30 31 32 10 11 12 08 09 28 29

MUT MUT03 MUT03 MUT03 MUT04 MUT04 MUT04 MUT05 MUT05 MUT05 MUT05

Unit F:EIOP F:EIOP F:EIOP F:EIOP F:EIOP F:EIOP F:BIOP F:BIOP F:BIOP F:BIOP

Connector C101P1 / DCCMD 0, LAUB 0 and 1 C323P1 / DCCMD 1, LAUB 2 and 3 C341P1 / DCCMD 2, LAUB 4 and 5 C101P1 / DCCMD 0, LAUB 0 and 1 C323P1 / DCCMD 1, LAUB 2 and 3 C341P1 / DCCMD 2, LAUB 4 and 5 C101P1 / DCCMD 0 and 1 - side0 C203P1 / LAUB 0 and 1 - side 0 C233P1 / DCCMD 0 and 1 - side 1 C335P1 / LAUB 0 and 1 - side 1

Tab. 2.8

Fuse Assignment R:CP113E

32

A30828-X1160-M-2-7620

Maintenance Node

Construction

FU 07 27 05 25 06 26 02 22 03 23 04 24 01 21

MUT MUT06 MUT06 MUT07 MUT07 MUT07 MUT07 MUT08 MUT08 MUT08 MUT08 MUT08 MUT08 MUT10 MUT10

Unit FANTRAY FANTRAY F:BPCE F:BPCE F:BPCE F:BPCE F:EPCE F:EPCE F:EPCE F:EPCE F:EPCE F:EPCE FANBOX FANBOX X1 / X2 X6 / X7 C209 X1, module side 0 C209 X2, module side 0 C285 X1, module side 1 C285 X2, module side 1

Connector

C141 X1, MODE 0 and MDDE 0 C141 X2, MODE 0 and MDDE 0 C243 X1, CAP 8, 10, 12, 14 C243 X2, CAP 9, 11, 13, 15 C359 X1, MODE 1 and MDDE 1 C359 X2, MODE 1 and MDDE 1 X1 / X2 X6 / X7

Tab. 2.8

Fuse Assignment R:CP113E

A30828-X1160-M-2-7620

33

Construction

Maintenance Node

2.7

R:DEVBR:DEVB - C2631 Fuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel F:MODEM F:MODEM

MUT01 MUT02 MUT03

D:MTD 1

MUT04

D:MTD 0

MUT07

D:DCIRB0 or F:MODEM D:DCIRB1 or F:MODEM rack 8 ft.

MUT10 MUT11

FU 05 02 19 20 MUT04 MUT07 MUT10 MUT11

MUT MTD 1 MTD 0 F:MODEM or D:DCIRB 0 F:MODEM or D:DCIRB 1

Tab. 2.9

Fuse Assignment R:DEVB - C2631

34

A30828-X1160-M-2-7620

Maintenance Node

Construction

R:DEVB - C2717 Fuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel F:MODEM F:MODEM

MUT01 MUT02 MUT03

D:MTD 1

MUT04

D:MTD 0

MUT07

D:DCIRB0 or F:MODEM D:DCIRB1 or F:MODEM rack 8 ft.

MUT10 MUT11

FU 11 01 19 20 MUT04 MUT07 MUT10 MUT11

MUT MTD 1 MTD 0 DCIRC 0 DCIRC 1

Unit MTD 1 MTD 0

MOLOC

Supply voltage for F:MODEM / MUT02 Supply voltage for F:MODEM / MUT03

Tab. 2.10

Fuse Assignment R:DEVB - C2717 -

A30828-X1160-M-2-7620

35

Construction

Maintenance Node

R:DEVB - C2723 - Variant 1Fuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel

MUT01

D:MTD 1

MUT03

D:MTD 0

MUT04

F:DEV(F) or F:DEV(E) FAN (B5681) 0 FAN (B5681) 1 FILTER:FAN

MUT10 MUT11 MUT12 MUT13

rack 7 ft.

FU 11 01 02 12 03 13 MUT03 MUT04 MUT10 MUT10 MUT11 MUT12

MUT MTD 1 MTD 0

Unit MTD 1 MTD 0 MDD 0 MDD 1

MOLOC

F:DEV(E) or F:DEV(F) F:DEV(E) or F:DEV(F) Fan 0 Fan 1

Tab. 2.11

Fuse Assignment R:DEVB - C2723 - Variant 1

36

A30828-X1160-M-2-7620

Maintenance Node

Construction

R:DEVB - C2723 - Variant 2Fuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel A Shelf 0 F:DLU(A) for DSU C Shelf 1 F:MODEM(D)

MUT01

MUT02

MUT03

D:MTD

MUT04

F:DEV(F) or F:DEV(E) FAN (B5681) 0 FAN (B5681) 1 FILTER:FAN rack 7 ft.

MUT10 MUT11 MUT12 MUT13

FU 05 06 15 16 11 01 02 12 03 13

MUT MUT02 MUT02 MUT02 MUT02 MUT03 MUT04 MUT10 MUT10 MUT11 MUT12 F:DLU(A) F:DLU(A) F:DLU(A) F:DLU(A)

Unit A001, A058, A119

MOLOC

A010 - A052, A089 - A113 C001, C058, C119 C010 - C052, C089 - C113

F:MODEM (D) MTD F:DEV(E) or F:DEV(F) F:DEV(E) or F:DEV(F Fan 0 Fan 1 MTD MDD 0 MDD 1 Fan 0 Fan 1

Tab. 2.12

Fuse Assignment R:DEVB - 2723 - Variant 2

A30828-X1160-M-2-7620

37

Construction

Maintenance Node

2.8

R:DEVDFuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel

MUT01

F:IOP 0 / 2

MUT03

Fuse Panel

MUT01

F:IOP 1 / 3

MUT04

F:IOP 2

MUT06

FAN (B5681)

MUT05

F:IOP 3 FAN (B5681)

MUT07 MUT08 MUT03

D:MTD

MUT06

F:IOP 0

F:IOP 1 FAN (B5681) F:DEV(F) or F:DEV(E) FAN-BOX (B5877) MUT08 F:DEV(F) or F:DEV(E) FAN-BOX (B5877) rack 7 ft.

MUT04 MUT10 MUT05 MUT12

MUT12

rack 8 ft.

FU 01 02 05 06 11 12 15 16 04 09 10 03

MUT in rack 8 ft. MUT03 / F:IOP 0/2 MUT03 / F:IOP 0/2 MUT03 / F:IOP 0/2 MUT03 / F:IOP 0/2 MUT04 / F:IOP 1/3 MUT04 / F:IOP 1/3 MUT04 / F:IOP 1/3 MUT04 / F:IOP 1/3

MOLOC in 8 ft. C101 C331 M:LAUB M:LAUB C101 C331 M:LAUB M:LAUB

MUT in rack 7 ft. MUT03 / F:IOP 0 MUT03 / F:IOP 0 MUT03 / F:IOP 0 MUT03 / F:IOP 0 MUT04 / F:IOP 1 MUT04 / F:IOP 1 MUT04 / F:IOP 1 MUT04 / F:IOP 1 MUT06 / F:IOP 2 MUT06 / F:IOP 2 MUT06 / F:IOP 2

MOLOC in 7 ft. C101 C331 M:LAUB M:LAUB C101 C331 M:LAUB M:LAUB C331 M:LAUB M:LAUB C101

MUT06 / MTD 0

MTD

MUT06 / F:IOP 2

Tab. 2.13

Fuse Assignment R:DEVD

38

A30828-X1160-M-2-7620

Maintenance Node

Construction

FU 13 18 19 20 14 07

MUT in rack 8 ft.

MOLOC in 8 ft.

MUT in rack 7 ft. MUT07 / F:IOP 3 MUT07 / F:IOP 3 MUT07 / F:IOP 3 MUT07 / F:IOP 3

MOLOC in 7 ft. C101 C331 M:LAUB M:LAUB

MUT05 / FAN MUT08 / F:DEV(F)/(E) MDD0 / MOD0

MUT08 / FAN MUT10 / FAN MUT05 / F:DEV(F)/(E) MUT05 / F:DEV(F)/(E) MUT12 / FAN-BOX

MDD 0 / MOD 0 MDD 1 / MOD 1

17 08

MUT08 / F:DEV(F)/(E) MUT12 / FAN-BOX

MDD1 / MOD1

Tab. 2.13

Fuse Assignment R:DEVD

2.9

R:DLUA Conguration ABAB or CFuse PanelFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel A Shelf 0 F:DLU(A) C Shelf 1

MUT01

MUT02 A

Fuse Panel Shelf 0 F:DLU(A)

MUT01

A

Shelf 2 F:DLU(B) MUT03 C A

MUT02

Shelf 1 Shelf 2 F:DLU(B) MUT03

C

Shelf 3

A

Shelf 0 F:DLU(A) MUT05

C A

Shelf 3 Shelf 0 F:DLU(A) MUT05

C A

Shelf 1 Shelf 2 F:DLU(B) MUT06

C

Shelf 1 Shelf 2 F:DLU(C)

C

Shelf 3 rack 8 ft.

A

MUT06

rack 7 ft.

A30828-X1160-M-2-7620

39

Construction

Maintenance Node

FU 01 05 11 15 02 06 12 16 03 07 13 17 04

MUT MUT02 MUT02 MUT02 MUT02 MUT03 MUT03 MUT03 MUT03 MUT05 MUT05 MUT05 MUT05 MUT06

Unit F:DLU(A) / Shelf 0 F:DLU(A) / Shelf 0 F:DLU(A) / Shelf 1 F:DLU(A) / Shelf 1 F:DLU(B) / Shelf 2 F:DLU(B) / Shelf 2 F:DLU(B) / Shelf 3 F:DLU(B) / Shelf 3 F:DLU(A) / Shelf 0 F:DLU(A) / Shelf 0 F:DLU(A) / Shelf 1 F:DLU(A) / Shelf 1 F:DLU(B) / Shelf 2 or F:DLU(C) / Shelf 2 F:DLU(B) / Shelf 2 or F:DLU(C) / Shelf 2 F:DLU(B) / Shelf 3 F:DLU(B) / Shelf 3 A001, A058, A119

MOLOC

A010 - A052, A089 - A113 C001, C058, C119 C010 - C052, C089 - C113 A001, A119 A010 - A052, A071 - A113 C001, C119 C010 - C052, C071 - C113 A001, A058, A119 A010 - A052, A089 - A113 C001, C058, C119 C010 - C052, C089 - C113 A001, A119

08

MUT06

A010 - A052, A071 - A113

14 18

MUT06 MUT06

C001, C119 C010 - C052, C071 - C113

Tab. 2.14

Fuse Assignment R:DLUA, Conguration ABAB or C

40

A30828-X1160-M-2-7620

Maintenance Node

Construction

2.10

R:DLUA Conguration ABBB or CFuse Panel 8 ft. rackFU 01 03 05 04 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 FU FU

FU 02

Fuse Panel A Shelf 0 F:DLU(A) C A Shelf 1 Shelf 2 F:DLU(B) C Shelf 3

MUT01

MUT02 A

Fuse Panel Shelf 0 F:DLU(A)

MUT01

MUT02

MUT03

C A

Shelf 1 Shelf 2 F:DLU(B) MUT03

A

Shelf 4 F:DLU(B) MUT05

C A

Shelf 3 Shelf 4 F:DLU(B) MUT05

C A

Shelf 5 Shelf 6 F:DLU(B) MUT06

C

Shelf 5 Shelf 6 F:DLU(C)

C

Shelf 7 rack 8 ft.

A

MUT06

rack 7 ft.

FU 01 05 11 15 02 06 12 16 03 07 13 17

MUT MUT02 MUT02 MUT02 MUT02 MUT03 MUT03 MUT03 MUT03 MUT05 MUT05 MUT05 MUT05

Unit F:DLU(A) / Shelf 0 F:DLU(A) / Shelf 0 F:DLU(A) / Shelf 1 F:DLU(A) / Shelf 1 F:DLU(B) / Shelf 2 F:DLU(B) / Shelf 2 F:DLU(B) / Shelf 3 F:DLU(B) / Shelf 3 F:DLU(B) / Shelf 4 F:DLU(B) / Shelf 4 F:DLU(B) / Shelf 5 F:DLU(B) / Shelf 5 A001, A058, A119

MOLOC

A010 - A052, A089 - A113 C001, C058, C119 C010 - C052, C089 - C113 A001, A119 A010 - A052, A071 - A113 C001, C119 C010 - C052, C071 - C113 A001, A119 A010 - A052, A071 - A113 C001, C119 C010 - C052, C071 - C113

Tab. 2.15

Fuse Assignment R:DLUA, Conguration ABBB or C

A30828-X1160-M-2-7620

41

Construction

Maintenance Node

FU 04

MUT MUT06

Unit F:DLU(B) / Shelf 6 or F:DLU(C) / Shelf 6 F:D


Recommended