DATA SHEET
Radio measuring capsule heat meter type 4.5.1
Precise measurement even with very small flow rates. Simple. With radio. Without entering the apartment.
The type 4.5.1 is the newest generation of Techem measuring capsule heat meter. It combines calculator,
volume measuring unit and temperature sensor in one. In the radio 4 device version, the consumption
data determined are transmitted by radio.
More IQ per °C
The measuring capsule‘s due date programable calculator
offers a diverse range of display functions, amongst others
energy, due date, energy status at the due date, flow rate,
inlet and outlet temperatures, temperature difference, per-
formance, volume and with cyclical self-test and diagnosis
display for the flow direction and temperature sensor in-
stallation. As much intelligence as you can fit in a measuring
capsule of this size!
Heat meter type 4.5.1 radio 4
The type 4.5.1 radio 4 is radio activated and automatically
transmits reading values after installation in the apartment.
The radio telegram contains current as well as mid month
and month end values to eliminate the need for arranging
appointments, intermediate readings or anyone needing to
enter the apartment. The data is encrypted and secured using
the CRC method.
In a nutshell
multijet meter technology ensures high measuring accuracy and stability
Installation location (inlet/outlet) programmable during installation
Reading flexibility with radio telegrams regarding OMS
(Open Metering Systems) standard
OMS certificated telegram configurable
approved for overhead installation, easy to install measuring capsule method
cable of the inlet temperature sensor with up to 6 m length
optional removable calculator
Secure data transfer by encryption and CRC method
MID approval (Measuring Instruments Directive)
Base for measuring accuracy is a water quality according to the working sheet
AGFW FW 510 and VDI 2035
Techem Energy Services GmbH · Hauptstr. 89 · 65760 Eschborn · www.techem.com
DATA SHEET
Radio measuring capsule heat meter type 4.5.1
8485
3.04
.091
9/IN
T ·
Err
ors
an
d c
han
ges
res
erve
d.
Dimensions compact
Dimensions with removable calculator
Technical data Main meter
Nominal flow qp (m3/h) 0.6 1.5 2.5
Maximum flow qs (l/h) 1,200 3,000 5,000
Minimum flow qi (l/h) 24 30 50
Startup horizontal (l/h) 2 2 2.5
Startup vertical (l/h) 8 8 12
Pressure loss at qp (bar) 0.03 0.20 0.24
Pressure loss at qs (bar) 0.1 0.74 0.92
kvs value (∆p = 1 bar) (l/h) 3270 3270 5050
Temperature of medium OMed (°C) 15 … 90
Protection class IP 65
Nominal pressure PN (bar) 16
Connection thread on meter Measuring capsule M 62 x 2 optional: type Ista (2“), type Allmess (M77 x 1,5), type Minol (M60 x 1,5)
Technical data Calculator and temperature sensor
Meter temperature range O (°C) 0 … 105
Temperature difference ∆O (K) 3 ... 100*
Consumption calculation ∆O (K) from 0,3
Ambient temperature O (°C) 5 … 55
Environmental conditions E1 + M1, class C
Power supply 5 years + reserve
Protection class calculator IP 65
* in symmetrical installation of the temperature sensor pair
Technical data radio
Radio mode unidirectional Standard: Mode C1 according to OMS V4
Radio data transmission Standard: – Annual due date (as OMS data point) – Consumption data from 12 mid-month and end of the month values – Status information
Transmitting frequency (MHz) 868.95
Transmiting power (W) 0.003 ... 0.015
Transmission period (sec.) 0.008 … 0.014
CE-conformity According to guideline 2014/53/EU (RED)
Data security Encryption according to OMS standard; recognised by BSI TR-03109
Future-proof design prepared for EED (Directive 2012/27/EU)
Pressure loss graph for measuring capsule meters
Flow Q (l/h)
Pres
sure
loss
p (m
bar)
qp 0.61,200
600
1000
0 6,0002,000 12,000
qp 1.5 qp 2.5