Rainsoft Division of Aquion Water Treatment Products, ltC 2080 East LuntAvenue, ElkGrove Village, Illinois60007 Tel:847-437-9400 www.rainsoft.com Treatment Systems A I R STERULTRft Dllil©~[}DO~~®llil~ @W])®[{@ ~[}llil[]][}D REV 11/23/04 #UT1OOO
Transcript

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 1/9

R a in so ft D iv is io n o f A q u io n W a te r T re atm e n t P ro d uc ts , lt

2 08 0 E ast L un t A ve nu e, E lk G ro ve V illa ge , Il lin ois 6 0 00

T el: 8 47 -4 37 -9 40 0 • www.ra insof t . com

Treatment Systems

A IR S T E R U L T R f t

Dll i l©~[}DO~~®ll i l~@W])®[{@ ~[}llil[]][}D

REV 11 / 2# U T

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 2/9

TABLE OFCONTENTS

Enjoying Your Airmaster Ultra Unit 3

Important Safety Instructions 3

Unpacking Your Airmaster Ultra Unit 4

Airmaster Ultra Installation 5

Adjusting the Ozone Output Level 6

Maintenance Requirements 7

.Airmaster Ultra Parts List 8

Specifications 8

Troubleshooting Guide , 9

Warranty 1 0

Rectangle Installation Template 11

Hole Saw Installation Template 12

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 3/9

Congratulationsl You now own the finest whole-house air treatment system available to homeowners.

To make operating and maintaining your unit as simple as possible, please read the contents of this

Owner's Manual.

This unit was shipped from the factory ready for operation and will begin delivering cleaner, fresher air

the instant your heating/cooling system is turned on.

This unit is designed to help remove household odors ranging from food, tobacco smoke, pets and other

objectionable smells that may be present in your home.

To receive optimal benefit and performance from the unit, your furnace or air conditioner fan should be

in the "ON" position at all times.

IMPORTANT SAFETY INSTRUCTIONS

Always make sure the system is unplugged during installation or service procedures.

WARN ING :

T h e u ltra vio le t lig ht p ro du ce d b y th e

U V lam ps is harm fu l to th e e ye s. Don ot lo ok d ire ctty a t th e lam p s. S ho uld

it b ec ome ne ce ss ar y to look at the

lamps, u s e UV -p ro te cte d sung la ss es .

The AirMaster Ultra may be .

installed either in the main

return duct or main supply duct

as shown in the diagram.

When installing on the supply

side, locate it as far away

from the heating sourceas practical while

remaining in the main

air stream.

A ir F lowfrom H ou se

AirMasterU ltra Un it

ReturnA ir D uct

<>A ir F lo wto H ous e

Supply

A ir D uct

Furnace

Insta ll A irM aster U ltra in return or supp ly duct

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 4/9

UNPACKING YOUR AIRMASTER ULTRA UNIT

Unpacking the Airmaster Ultra unit.

1. Each unit is shipped with the cover separated from the main

chassis assembly. This allows for the main chassis

assembly to be ready for installation.Germicidal

UV Lamp

2. Carefully remove unit from the package. The lamps arefragile and proper care must be taken when removing

packaging that is placed around them.Air FlowSensor--~

3. Do not touch the lamps with your bare hands, as oils from

your hands can create "hot spots" which reduce the lamp

life. In case of contact with the lamp, wipe the lamp clean

with a soft cloth dampened with rubbing alcohol.

4. Check the parts list below to make sure you have all of the components.

• One Airmaster Ultra air treatment system

- Main chassis assembly

- Cover- Two cover attachment screws

• One wall-mount transformer

• Four self-tapping screws

• Installation/owners manual

• Warranty card

• Wiring to connect from transformer to unit

(20', two-conductor cable with plug)

• 2 crimp terminals

• Wire tie

Main ChassisAssembly with Cover Removed

Display BoardRibbon Cable--'

Main Power Jack

Lamp Connector

Ozone Lamp End

- White Lamp Base

White Wires

Power Cord Retaining Wire Tie _..,

Cover

Display Board(under cover)

."» a

0Q,

~ :E;; a ~ Cl

!! l<II

."~ z3 0'

• l~

rn» c:

!£ :EIU'l ~Q,

;~

! ! ! . .! ! ! . .

. '--t

N'

r'-'1 ~ S § .

m

!!l~,e'

r i l_ \ ~

5 . .iH~~

Side View

Ballast

Air Flow Sensor

Germicidal Lamp En

- Yellow Lamp Base

Yellow Wires

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 5/9

AIRMASTER ULTRA INSTALLATION

W h ile p re fo rm in g in sta lla tio n p ro ce du re s a ll p ow er to the un it m ust be 'O ff' and there must be no airflow

th ro ug h th e h eatin g/co olin g sy ste m.

1. One of two templates may be used for installation of the AirMaster Ultra.

• 'Rectangle Installation Tempiate'located on page 11.

• 'Hole Saw Installation' located on page 12.

2. Center the installation template on the ductwork using tape. N ote: T he insta lla tion tem plate an d un it m ust

be m ounted lengthw ise and in d irec tion o f 'A irAow ' so tha t the UV G erm ic ida l Lam p is upstream and the

UV O zone Lam p is dow nstream .

3. Rec ta ngle I ns ta lla tio n T emp la te : Trace the cut out hole pattern on to the ductwork and mark holes for the

four mounting screws. H ole S aw In sta lla tio n T em plate : Mark holes for the four mounting screws.

4. Cut out openings in ductwork for the unit. See template for step and recommended tools.

5. Position AirMaster Ultra 'Main Chassis Assembly' into ductwork and secure with the self tapping screws

provided, using a 5/16" nut driver.

6. Cut the two conductor power cord to length, strip ends back 3/8" and crimp on the two fork connectors

provided.

7. Slide fork connectors under transformer screw-heads and tighten.

8. Insert the power cord through the cord retaining wire tie (located next to the ozone lamp). Plug power

cord into the main power jack.

9. Allow for a service loop in the power cord between the wire tie and the main power jack. Then draw the

wire tie tight around the power cord. No te : Cu t o ff any excess of the w ire tie w ith side cu tte rs . D o no t cu t

the pow er cord .

10. Plug the display board ribbon cable into the display board, located under cover and secure cover to mai

chassis. Assemble using the two screws provided.

11. Plug the transformer into a non-switched 120 VAC outlet. Note : All lights w ill rem ain on fo r 30 to 120

seconds . A fter th is tim e the' A irflow ' and 'O dor N eutra lize r' ligh ts w ill tu rn o ff.

12. Turn 'On' heating/cooling system and allow it to operate for five minutes, at this time all lights should

illuminate.

13. Turn 'Off' heating/cooling system, the AirMaster Ultra will shut down within 5 to 30 seconds. After this

time the 'Airflow' and 'Odor Neutralizer' lights will turn off. The 'Power' and 'Germicidal' lights willremain on when unit is not in operation.

14. The AirMaster Ultra is now ready for use.

N ote : O zone air treatm ent occurs on ly w hen air is c ircu la ting thro ugh the heatin g/coo ling system. For

m axim um e ffe ctive nes s a nd co ntin uo us a ir p urific atio n, tu rn th e th erm os ta tic co ntro ller sw itch fro m th e

A U TO p os itio n to the O N pos ition . The sw itch is located on the therm ostat. O pen w indows or doors and d irty

d uc tw ork m a y d im in is h th e u nit's e ffe ctiv en es s.

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 6/9

ADJUSTING THE OZONE OUTPUT LEVEL

T he slid e sw itch o n th e co ver is u sed to ad ju st th e o zo ne ou tp ut leve l. T he settin gs a re lo w, m ed an d h ig h.

LOW - Use in an average-sized home with no pets, no tobacco smoke odors and minimum household odors.

M E D I U M - Use in an average-sized home with pets, confined tobacco smoke odors and minimum household

odors.

H IGH - Use in an average-sized home with pets, heavy tobacco smoke odors throughout the home and

moderate household odors.

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 7/9

MAINTENANCE REQUIREMENTS

The lamp cleaning schedule is determined by air quality. The recommended cleaning interval is every

12 months. The lamp replacement schedule is based on running time. The recommended replacement

interval is 24 months. Note: Do not touch the lamps with bare hands. Oils from the hands can create

"hot spots" which reduce the lamp life. Handle by either the end caps or use a soft cloth. In case of

contact with the lamp, wipe the lamp clean with a soft cloth dampened with rubbing alcohol.

C LEA NIN G THE LAM PS: Recommended every 12 months

1. Unplug the transformer from the wall outlet.

2. Remove the two screws from the cover of the unit and remove the cover.

3. Remove the four sheet metal mounting screws from air duct.

4. Carefully remove the unit from the air duct.

5. Using a soft cloth dampened with rubbing alcohol, wipe down the unit and the lamps. If there is

a large buildup of dust particles, you may wish to use a can of compressed air first to remove the

majority of the dirt.

6. Carefully replace unit into air duct.

7. Replace sheet metal screws, the cover, the two screws and plug the transformer into the wall outlet.

REP LACIN G THE LAMP S: Recommended every 24 months

NOTE: Use only RainSoft-approved lamps for replacement. Standard off-the-shelf lamps are not

compatible with your RainSoft AirMaster Ultra unit.

1. Unplug the transformer from the wall outlet.

2. Remove the two screws from the cover of the unit and remove the cover.

3. Disconnect the lamp connector from the end of a lamp.

4. loosen the lamp lock nut from around the end of the lamp by turning it counterclockwise and

remove (pliers may be required).

5. Remove the metal washer.

6. Remove lamp by grasping the rubber bushing around the end of the lamp. With a gentle rocking

motion, loosen the bushing from its seat and carefully slide it straight out.

7. Remove the rubber bushing from the old lamp and install it on the new lamp.

8. Slide the new lamp back into the lamp opening. Handle lamp by the end cap(s).

9. Re-install the metal washer and lamp lock nut. Carefully tighten the lamp lock nut.

10. Reconnect the lamp connector to the end of the lamp.

11. Repeat steps #3 to # 10 when replacing the other lamp.

12. Replace the cover and secure it with the two screws.

13. Plug the transformer into the wall outlet.

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 8/9

A IRMASTER ULTR A P AR TS L IS T

ITEM# DESCRIPTION

4

5

6

7

PART # SPECIFICATIONS

2

3

AirMaster Ultra Assembly 65052

AirMaster Ultra Ozone Lamp 6550 1

AirMaster Ultra Germicidal

Lamp 65048

AirMaster Ultra Fuse 65005

AirMaster Ultra Flow Sensor 65061

Germicidal Lamp

Germicidal lamp is 254 nm, hot filament.

Average life is 20,000 hours.

Ozone Lamp

Ozone lamp is 185 nm, cold cathode.

Average life is 20,000 hours.

AirMaster Ultra Ballast (Board) 65062

AirMaster Ultra Transformer 65000

Input

24 Yac, 60 Hz, 50YA

8 AirMaster Ultra Display (Board) 65063

9 AirMaster Ultra Ribbon Cable 65064

C D

._ - ----.._

- -- -

Ell

8/7/2019 Rainsoft Air Master Ultra

http://slidepdf.com/reader/full/rainsoft-air-master-ultra 9/9

TROUBLESHOOTING GUIDE

SYMPTOM SOLUTION

N o pow er Verify that the transformer is properly plugged into wall

outlet and the power cord into the power jack on unit.

If the cord is properly connected, test the wall outlet with

AC tester to make certain it is functioning properly. If not

working, consult an electrician.

If u nit s till d oe s n ot fu nc tio n If there is power to the wall outlet, remove cover from the

Airmaster Ultra unit, unplug the power cord from the power

jack on the AirMaster unit. Using a voltmeter, measure the

AC voltage from the transformer. Make sure the voltage is

21 to 26 volts. li not, replace the transformer. (Item # 7,

Page 8).

If unit is still not working, remove cover from the AirMaster

unit and check the fuse on the circuit board. If fuse is

blown, replace (Item # 4, Page 8).

Check the power light. If light is still not on, replace the

ballast. (Item # 6, Page 8).

Fo r the fo llow ing tes ts m ake su re there is no a ir flow

a c ro s s u n it .

A ir f low tes t

Unplug the power cord from the power jack for 1 to 2

minutes. Plug the power cord back into the power jack. The

'Air Flow' light will illuminate for 30 to 120 seconds. After

the light turns off, start the heating/cooling system. The

'Air Flow' light should illuminate within 30 seconds. If not,

replace the air flow sensor (Item # 5, Page 8). If that does

not work, replace the ballast. (Item # 6, Page 8).

T es tin g th e la m ps T es tin g th e lam ps requ ire s th e h ea tin g/co olin g s ys tem to b e

runn ing .

If ozone lamp is not lit, replace (Item # 2, Page 8).

If the germicidal lamp is not lit, replace (Item # 3, Page 8).

If this does not work, replace the ballast (Item # 6, Page 8).

If above tes ting does no t w ork , con tac t you r loca l R ainS oft D ea le r.