4
Building Solutions Automotive Industry www.rehau.co.uk/districtheating RAUTHERMEX PRE-INSULATED PE-XA PIPE FOR DISTRICT HEATING ENERGY EFFICIENCY
Transcript

Building SolutionsAutomotive

Industry

www.rehau.co.uk/districtheating

rauthermexPre-INSuLateD Pe-xa PIPe for DIStrIct heatINg

ENERGYEFFICIENCY

With the increase of district heating in the UK, specifiers and contractors are increasingly looking at the pipe’s performance to optimise both installation and operational costs. REHAU’s RAUTHERMEX pipe offers excellent insulation performance through its Polyurethane (PU) foam with a lambda value of 0.0216W/mK (according to EN 253).

RAUTHERMEX is available in single pipe (UNO) up to 160mm /and twin pipe (DUO) up to 63mm, with a comprehensive range of fittings and accessories. The new RAUTHERMEX 140mm pipe is the largest flexible pipe available on the market, coming in 75m coils.

Benefits at a glance:

- Excellent thermal insulation performance from closed cell PU foam insulation- Long lengths up to 560m possible, reducing the number of joints needed for long pipe runs- Uses renowned REHAU EVERLOC™ leak-proof fittings and tools- Suitable up to 95°C and 6 bar operating pressure- Generation II Shroud technology requires no hot works on site- Full UK stock with cut-to-length service available- No need to compensate for thermal expansion due to pipe makeup- Robust LLD-PE outer sleeve to cope with tough on-site conditions

rauthermexPre-INSuLateD Pe-xa PIPe for DIStrIct heatINg

RAUTHERMEX offers significant installation savings over steel pipes as there is no need for time-intensive welding every 6 to 12m, long coils can be used and the pipe is easy to handle on site. Lower flow temperatures (e.g. 80°C) are now being used in modern district heating systems, allowing PE-Xa pipe to be the material of choice for contractors.

REHAU compression sleeve – a superior jointing technique

The REHAU compression sleeve system for connecting PE-Xa pipes has proven itself over 100 million times in installations of underfloor heating & plumbing in domestic and commercial applications.

The REHAU EVERLOCTM compression sleeve:- Quick and simple, offering low-cost installation

rauthermexPre-INSuLateD Pe-xa PIPe for DIStrIct heatINg

REHAU can assist with pipe sizing, heat loss calculations and also create a bill of materials for your heat network. Contact REHAU today at [email protected] to discuss your project requirements

- Permanently secure and inseparable pipe joints- Optimum hydraulic performance due to minimal bore reduction

Potential Applications for RAUTHERMEX:- District heating / community heating - Biomass boilers- CHP / remote boilers- Biogas / AD plants- Heat pumps- Swimming pools- Cooling equipment

www.rehau.co.uk/districtheating 463700EN 12.2013

rehau SuStaINaBLe SoLutIoNSfor eNergY effIcIeNt BuILDINgS

RAUVITHERM PE-Xa pre-insulated pipe RAUBIO digester heating RAUBIO gas condesation chamber

Underfl oor Heating RAUGEO ground-source probes AWADUKT Thermo ground-air heat exchanger

UK & IRELAND SALES OFFICES London, REHAU Ltd, The Building Centre, 25 Store Street, London WC1E 7BT Phone: 0207 580 6155 Fax: 0207 307 8595 Slough, Units 5 J & K, Langley Business Centre, Station Road, Langley, Slough SL3 8DS Phone: 01753 588500 Fax: 01753 588501 Manchester, Brinell Drive, Irlam, Manchester M44 5BL Phone: 0161 777 7400 Fax: 0161 777 7401 Glasgow, Phoenix House, Phoenix Crescent, Strathclyde Business Park, Bellshill, North Lanarkshire ML4 3NJ Phone: 01698 503700 Fax: 01698 503701 Dublin, 9 St. Johns Court, Business Park, Swords Road, Santry, Dublin 9 Phone: 00353 (0)1 8165020 Fax: 00353 (0)1 8165021

Our verbal and written application engineering advice is based upon experience and the best of our knowledge. However it is to be regarded as non-binding information. Working conditions and use under conditions for which the product was not intended and over which we have no infl uence exclude any claim resulting from our information. We recommend that a suitable check is made as to whether the REHAU product is suitable for the envisaged purpose. Application, use and processing of the products is carried out beyond the scope of our control and are therefore carried out exclusively at your own responsibility. If liability should still apply, then this is restricted, in the case of all damage, to the value of the goods supplied by us and used by you. Our warranty applies to the consistent quality of our products as per our specifi cation and in accordance with our general terms and conditions of delivery and payment. This document is protected by copyright. All rights based on this are reserved. No part of this publication may be translated, reproduced or transmitted in any form or by any similar means, electronic or mechanical, photocopying, recording or otherwise, or stored in a data retrieval system.