Copyrights © All rights reserved
Content
1. Introduction ------------------------------------------------------------------------------ 3 - 7 2. Specification of Floor height,beam,slab,wall & staircase standard -------- 8 - 9 3. Specification of Wall standard ------------------------------------------------------ 10 - 11 4. Specification of Dimensioning codes ---------------------------------------------- 12 - 14 5. Specification of Staircase standard ------------------------------------------------ 15 - 21 6. Specification of Type A column standard ----------------------------------------- 22 - 26 7. Specification of Type B column standard ----------------------------------------- 27 - 31 8. Specification of Door frame standard --------------------------------------------- 32 - 35 9. Specification of Window opening standard -------------------------------------- 36 - 37
DESIGN STANDARD
Copyrights © All rights reserved
DESIGN STANDARD
Design standard is a preferred standard for advance designing & coordination.
Also a key to unlock the futuristic type of design for green and smart buildings.
DESIGN STANDARD
3
Copyrights © All rights reserved
Design standard has the advantages for building projects such as error free, fast installation ,easy coordinating ,more reusable sizes, wastages prevention , systematic arrangement ,better working environment & inventory control.
DESIGN STANDARD
4
Copyrights © All rights reserved
The design standard comply with RBM formwork system details as specified which accordance with the MS1064 : modular coordination in buildings.
DESIGN STANDARD
5
Copyrights © All rights reserved
DESIGN STANDARD
The dimension that specified for floor height, wall thickness, beam height , slab thickness ,dimensioning codes , different column design & different staircase design are set to apply for all type of building such as residential and commercial building known as design standard.
6
To build any type of residential , commercial building .The building design always consists of different areas , sections ,sizes , parts ,& special features to show it’s unique & creative ideas on architectural design. However ,the building requirements still remain the same such as structural works , building external & internal works, finishing , electrical point installation, & plumbing works . RBM formwork system according to the design standard will ensure most of the standard sizes are keep on repeating and able to reuse again for next project. Also, Formwork installation just using panel with clip that reduce lot of messy & difficult handling job to keep the area clean & safety as compare to conventional plywood formwork environment. Also , choosing the RBM formwork system is more environmental friendly as it’s is made from steel which is recyclable material & very durable . So, that all remarks as green . As a smart performance way, according to the design standard as specified , it will prevent any error happen during the formwork installation. Design standard able to minimize the formwork into few requires sizes only. This helps to reduce the time of formwork arrangement & much easier to control all the formwork inventory as supply to site. This also allow the formwork installer to pick and install the right panel in right position as coordinated in the drawing plan more faster without confuse by too many sizes . In a new revolutionary of building industries , complete a project with green & smart way ,the works must be faster , easier , environmental friendly & better quality. RBM had developed such design standard specification to allow RBM formwork system standard to works efficiently for any type of building design.
Copyrights © All rights reserved
DESIGN STANDARD
Introduction
Green Efficiency
Smart Performance
New Concept
7
Copyrights © All rights reserved
Specification of
Floor height,beam,slab,
wall & staircase standard
8
Specification of floor height , beam, slab ,wall, staircase standard
No. Description Symbol Dimension
1 Floor height H (total) 3300mm 3600mm 3900mm 4200mm 4500mm
2 Beam height Bh 450mm 600mm 750mm 900mm 1200mm 1500mm
3 Slab thickness S 150mm 200mm
4 Wall thickness a 150mm 200mm
5 Staircase Riser Riser 150mm
6 Staircase Tread Tread 200mm 250mm
7 Staircase Thickness
T 100mm
8 No.of step No. Hs (total)/ riser
Copyrights © All rights reserved
9
SIDE VIEW
Copyrights © All rights reserved
Specification of
Wall standard
10
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Interlocking width il 50mm
3 Interlocking depth iw 10mm
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
Specification of wall standard
Copyrights © All rights reserved
11
TOP VIEW TOP VIEW
Option 1 Option 2
Copyrights © All rights reserved
Specification of
Dimensioning codes
12
Specification of dimensioning codes
Copyrights © All rights reserved
13
TOP VIEW
Specification of dimensioning codes
Copyrights © All rights reserved
14
TOP VIEW
Copyrights © All rights reserved
Specification of
staircase standard
15
Specification of straight staircase standard
Copyrights © All rights reserved
16
No. Description Symbol Dimension
1 No. of step No. Hs ( total) / riser
2 Total staircase height Hs (total) 3300mm 3600mm 3900mm 4200mm 4500mm
3 Staircase riser Riser 150mm
4 Staircase tread Tread 200mm 250mm
5 Staircase thickness T 100mm
No. Description Symbol Dimension
1 Step Length Ls 900mm 1200mm
2 Staircase Length L L = no.of tread
Copyrights © All rights reserved
17
TOP VIEW
SIDE VIEW
Specification of single landing staircase standard
Copyrights © All rights reserved
18
No. Description Symbol Dimension
1 No. of step No. Hs ( total) / riser
2 Total staircase height
Hs (total) 3300mm 3600mm 3900mm 4200mm 4500mm
3 Staircase riser Riser 150mm
4 Staircase tread Tread 200mm 250mm
5 landing height Hs 1, Hs 2 Hs 1,Hs 2 = No.of riser
6 Staircase Thickness
T 100mm
No. Description Symbol Dimension
1 Step Length Ls 1,Ls 2,Ls 3
900mm 1200mm
2 Gap g 50mm
3 Landing Width W W= Ls + g
4 1st staircase length L1 L1 = W + no.of tread
5 2nd staircase length L 2 L2 = Ls1+ Ls2 +150
6 3rd staircase length L 3 L3 = W +no.of tread
Copyrights © All rights reserved
19
TOP VIEW
SIDE VIEW
Specification of double landing staircase standard
Copyrights © All rights reserved
20
No. Description Symbol Dimension
1 Step Length Ls 1,Ls 2,Ls 3 900mm 1200mm
2 Gap g 50mm
3 Landing Width W W= Ls + g
4 1st staircase length L1 L1 = W + no.of tread
5 2nd staircase length L 2 L2 = Ls1 + no.of tread + W
6 3rd staircase length L 3 L3 = Ls +no.of tread
No. Description Symbol Dimension
1 No. of step No. Hs ( total) / riser
2 Total staircase height
Hs (total) 3300mm 3600mm 3900mm 4200mm 4500mm
3 Staircase riser Riser 150mm
4 Staircase tread Tread 200mm 250mm
5 landing height Hs 1, Hs 2 , Hs 3
Hs 1,Hs 2,Hs 3 = No.of riser
6 Staircase thickness
T 100mm
Copyrights © All rights reserved
21
TOP VIEW
SIDE VIEW
Copyrights © All rights reserved
Specification of
type A column standard
22
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Standard size b 300mm 350mm 400mm 450mm 600mm
3 Interlocking depth iw 10mm
4 Interlocking length il 50mm
Column Type A1 Specification
Copyrights © All rights reserved
23
TOP VIEW
3D VIEW
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Standard size b b = a + c
3 Corner c 100
4 Interlocking depth iw 10mm
5 Interlocking length il 50mm
Column Type A2 Specification
Copyrights © All rights reserved
24
TOP VIEW
3D VIEW
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Standard size b b = a + 2c
3 Corner c 100
4 Interlocking depth iw 10mm
5 Interlocking length il 50mm
Column Type A3 Specification
Copyrights © All rights reserved
25
TOP VIEW
3D VIEW
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Corner c 100
3 Interlocking depth iw 10mm
4 Interlocking length il 50mm
Column Type A4 Specification
Copyrights © All rights reserved
26
TOP VIEW
3D VIEW
Copyrights © All rights reserved
Specification of
type B column standard
27
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Standard size b 300mm 350mm 400mm 450mm 600mm
3 Corner c 100
4 Interlocking depth iw 10mm
Column Type B1 Specification
Copyrights © All rights reserved
28
TOP VIEW
3D VIEW
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Standard size b b = a+3c
3 Corner c 100
4 Additional standard size
d 300mm 350mm 400mm 450mm 600mm
5 Interlocking depth iw 10mm
Column Type B2 Specification
Copyrights © All rights reserved
29
TOP VIEW
3D VIEW
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Standard size b b = a+4c
3 Corner c 100
4 Additional standard Size
d 300mm 350mm 400mm 450mm 600mm
5 Interlocking depth iw 10mm
Column Type B3 Specification
Copyrights © All rights reserved
30
TOP VIEW
3D VIEW
No. Description Symbol Dimension
1 Wall thickness a 150mm 200mm
2 Corner c 100
3 Additional standard size
d 300mm 350mm 400mm 450mm 600mm
4 Interlocking depth iw 10mm
Column Type B4 Specification
Copyrights © All rights reserved
31
TOP VIEW
3D VIEW
Copyrights © All rights reserved
Specification of
Door frame standard
32
Type Height (Hd ) Width (Wd)
1 2400 750
2 2400 900
3 2400 1200
4 2100 750
5 2100 900
6 2100 1200
Metal door frame standard
Copyrights © All rights reserved
33
FRONT VIEW
Copyrights © All rights reserved
Door frame with 10mm arch accordance 200mm wall thickness
Metal door frame with arch specification
Door frame with 10mm arch accordance 150mm wall thickness
Note: Door frame profile ,anchor & hinges as door manufacturer specified.
34
TOP VIEW
Metal door frame without arch specification
Copyrights © All rights reserved
Door frame accordance 200mm wall thickness
Door frame accordance 150mm wall thickness
35
Note: Door frame profile ,anchor & hinges as door manufacturer specified
TOP VIEW
Copyrights © All rights reserved
Specification of
Window opening standard
36
Window Opening standard
No. Description Symbol Dimension
1 Floor Height H (total) 3300mm 3600mm 3900mm 4200mm 4500mm
2 Window width x 600mm 1200mm 1800mm 2400mm
3 Window height y 600mm 1200mm 1500mm
4 Window Level height
z 2100mm 2400mm
5 Window bottom level
f f = z – y
Window Opening
Copyrights © All rights reserved
37
Note: Window installation as window manufacturer specified.
FRONT VIEW
Copyrights © All rights reserved
Thank You
www.rbm.com.my