Building a New Electric World Telemecanique Altivar 11 Real efficiency at a reduced size!... Altivar 11 variable speed drives for asynchronous motors from 0.18 to 2.2 kW
Transcript
Page 1: Real efficiency at a reduced size!Altivar 68 75 to 630 kW Altivar 58 0.37 to 75 kW Altivar 38 0.75 to 315 kW Altivar 11 0.18 to 2.2 kW Variable speed drives Increase your performance

Building a New Electric World

TelemecaniqueAltivar 11Real efficiency at a reduced size!...

Altivar 11 variable speed drives for asynchronous motorsfrom 0.18 to 2.2 kW

mep ATV 11 flash corAng 10/07/02 13:23 Page 3

Page 2: Real efficiency at a reduced size!Altivar 68 75 to 630 kW Altivar 58 0.37 to 75 kW Altivar 38 0.75 to 315 kW Altivar 11 0.18 to 2.2 kW Variable speed drives Increase your performance

Altivar 11 :The little one with big prospects...

Standards and certifications: EN 50178 / EN 61800-3.EN 55011, EN 55022 class B and class A gr. 1NOM 117 / C-TICK.

The new Altivar 11 variable speeddrive is truly different, not only in size,but above all in its features:

Identical performance to the Greats.Uninterrupted service.Perfect suitability for any application.International coverage.

For motor powersfrom 0.18 to 2.2 kW

Voltage ranges:120 V single-phase.240 V single-phase.230 V 3-phase.

N998

The smallest drive in the world

mep ATV 11 flash corAng 10/07/02 13:23 Page 4

Page 3: Real efficiency at a reduced size!Altivar 68 75 to 630 kW Altivar 58 0.37 to 75 kW Altivar 38 0.75 to 315 kW Altivar 11 0.18 to 2.2 kW Variable speed drives Increase your performance

Thanks to the the advanced flux vectorcontrol and specific applicationfunctions of the Altivar 11:

Parking barriersExceptional dynamics:

Use of an advanced flux vector motor controlminimises cycle times.

Customisation of "Up / Down" cycles due to theassignment of several functions on the same logic input:

Different ramps for up / down cycles.Up priority if obstructed going down.Different pre-selectable speeds both for up / downcycles.

Answers to abrupt weather changes:Operation assured down to -10°C.

HoardingsSerial configurations and simplified maintenance:

Use of PowerSuite software workshopon standard PC or Pocket PC.

Optimisation of sizeUse of baseplate version.

Solutions for power supply line noise:Built-in EMC class B filters.

Reduction in generated pollution:Switching frequency of 16 kHz.

Dough mixersPerfect control of this motor drive application:

Without tripping as the dough hardens.Protection of personnel:

Due to the low leakage current of the Altivar 11,the drive can be associated with a 30 mA differentialcircuit-breaker. This also includes models with abuilt-in EMC class B filter.

ConveyorsTailored ergonomics, as near to the operator as possible:

Simple setting-up using local controls: start / stop buttons and potentiometer for setting speed available on the drive.

...for all your applicationsfrom 0.18 to 2.2 kW

Perfect for simple mechanicalapplications in industrial andcommercial sectors:

Mechanical handling:conveyors, garage doors, parkingbarriers, supplying conveyors, etc...

Special machines: grinders, saws, drills, exerciseequipment, hoardings,extractors, dough mixers, etc...

The performance and simplicityof the Altivar 11 will make youforget multispeed motors,mechanical drives, DC drives,special motors and electro-mechanical starters, etc.It easily replaces all these solutions.

mep ATV 11 flash corAng 10/07/02 13:23 Page 1

Page 4: Real efficiency at a reduced size!Altivar 68 75 to 630 kW Altivar 58 0.37 to 75 kW Altivar 38 0.75 to 315 kW Altivar 11 0.18 to 2.2 kW Variable speed drives Increase your performance

Identical performanceto the Greats

Uninterruptedservice

Total control of your machines:

Optimal management of the motor due to flux vectorcontrol: 150% of the nominal current of the drive during60 seconds with a 1:20 speed ratio.

Ability to catch a spinning load after a supply breakor on a start command for smooth take-up of arotating machine.

Dynamic braking possible, even for high inertia andunbalanced load applications.

Robustnessto meet everychallengeEven in severeenvironments from-10 up to +50° C, the Altivar 11 isperfectly operationalwithout anydegradation in itsperformance.

High degree of monitoring and protection at all levels:

Of the motor• thermal protection by continuous calculation of I2t.

Of the drive• thermal protection by PTC probe integrated in the

power module,• protection against short-circuits between output

phases.• safety related to the supply line:

- overvoltage,- undervoltage,- phase failure (on 3-phase)…

Of personnel• Due to the low leakage current of the Altivar 11,

the drive can be associated with a 30 mA differentialcircuit-breaker. This also includes models with abuilt-in EMC class B filter.

mep ATV 11 flash corAng 10/07/02 13:23 Page 5

Page 5: Real efficiency at a reduced size!Altivar 68 75 to 630 kW Altivar 58 0.37 to 75 kW Altivar 38 0.75 to 315 kW Altivar 11 0.18 to 2.2 kW Variable speed drives Increase your performance

The compactness of the Altivar 11 considerably reduces the size of your enclosures and, inaddition, reduces the size yet again due to thepossibility of mounting several drives side by side.

Through wiring and connection using captivescrews simplify installation and replacement ofelectromechanical solutions.

DIN rail mounting option also contributes to additionalsavings in installation time.

Multi-assignment of logic inputs (several functions onthe same input) increases tenfold its applicationcapabilities.

Perfect suitabilityfor any application

The Altivar 11 has its place anywhere in the world: its ranges are suitable for the technical requirements and standards of all the markets.

The smallest drive in the world !

International coverage

Example of assigningoperating functions toa single logic input

The closest possible tomachines...

The Altivar 11 couldnot be closer toyour machine:it can be installeddirectly on its framework (versionon baseplate).

The use of naturalconvection up to0.75 kW makesthem ideal wheresilent operation isnecessary.

Built-inEMCclass Bfilter(Europe).

Current NEC208 V 1999(NorthAmerica).

Localcontrolsand negativelogic.(Asia).

mep ATV 11 flash corAng 10/07/02 13:24 Page 6

Page 6: Real efficiency at a reduced size!Altivar 68 75 to 630 kW Altivar 58 0.37 to 75 kW Altivar 38 0.75 to 315 kW Altivar 11 0.18 to 2.2 kW Variable speed drives Increase your performance

Customise your settings with the minimum of effort

The built-in display guides you throughthe main parameters for fast configuration.

Does your application require particular settings?3 simple and intuitive menus allow you to:

adjust the parameters of your motor application,configure the specific functions of your machine,select the value indicated on the display of the drive….

For improved security, your settings can be automaticallysaved on the Altivar 11 and subsequently recalled.

Protect everything in memory withPowerSuite* software

In addition to its user-friendlinessand ergonomics for adjusting and storing your parameters,PowerSuite allowsthe back-upof each configuration.This, in turn,can be quickly recalled andused for similarapplicationswithout the risk oferror.

* Software which is common to the Altivar range of variable speed drives.Available in 5 languages (English, French, German, Italian, Spanish).

With total simplicityand user-friendliness

Wire it, connect it, start …Factory set, the Altivar 11 isoperational immediately.

mep ATV 11 flash corAng 10/07/02 13:24 Page 7

Page 7: Real efficiency at a reduced size!Altivar 68 75 to 630 kW Altivar 58 0.37 to 75 kW Altivar 38 0.75 to 315 kW Altivar 11 0.18 to 2.2 kW Variable speed drives Increase your performance

Altivar 11 selection guide

kW A 3-phase

Supply voltage : 200 to 240 V

0.18 1.1 ATV 11HU05M2E

0.37 2.1 ATV 11HU09M2E *

0.55 3 ATV 11HU12M2E *

0.75 3.6 ATV 11HU18M2E *

1.5 6.8 ATV 11HU29M2E

2.2 9.6 ATV 11HU41M2E

kW HP A Single-phase 3-phase

Supply voltage : 100 to 120 V

0.18 0.25 1.6 ATV 11HU05F1U -

0.37 0.5 2.4 ATV 11HU09F1U* -

0.75 1 4.6 ATV 11HU18F1U -

Supply voltage : 200 to 240 V 200 to 230 V

0.18 0.25 1.6 ATV 11HU05M2U ATV 11HU05M3U

0.37 0.5 2.4 ATV 11HU09M2U * ATV 11HU09M3U *

0,75 1 4.6 ATV 11HU18M2U * ATV 11HU18M3U *

1.5 2 7.5 ATV 11HU29M2U ATV 11HU29M3U

2.2 3 10.6 ATV 11HU41M2U ATV 11HU41M3U

kW A Single-phase 3-phase

Supply voltage : 100 to 120 V

0.18 1.4 ATV 11HU05F1A -

0.37 2.4 ATV 11HU09F1A * -

0.75 4 ATV 11HU18F1A -

Supply voltage : 200 to 240 V 200 to 230 V

0.18 1.4 ATV 11HU05M2A ATV 11HU05M3A

0.37 2.4 ATV 11HU09M2A * ATV 11HU09M3A *

0.75 4 ATV 11HU18M2A * ATV 11HU18M3A *

1.5 7.5 ATV 11HU29M2A ATV 11HU29M3A

2.2 10 ATV 11HU41M2A ATV 11HU41M3A

Variable speed drives with heatsink - 50 / 60 Hz

«Asia»range.Local controlson the drive andnegative logic.External EMCclass B filteras option.

«Europe»rangeBuilt-in EMCclass B filter.

«America»range.Permanent output current conforming to the standardNEC 208 V 1999.External EMCclass B filter as option.

ReferenceMotor power

Dimensions (in mm)Permanentoutputcurrent

ReferenceMotor power

Permanentoutputcurrent

ReferenceMotor power

Permanentoutputcurrent

* Replace the letter " H " by " P " to obtain the reference of the version on a baseplate.** Add 7 mm to the depth for the Asia range.

ATV11... w h d **

HU05 M2•/ M3• / F1• 72 142 101

HU09 M2• / M3• / F1• 72 142 125

HU12 M2• 72 142 138

HU18 M2• / M3• 72 142 138

HU18 F1• 117 142 156

HU29 M2• / M3• 117 142 156

HU41 M2• / M3• 117 142 156

On baseplate

PU•• M2• / M3• / F1• 72 142 101w : width / h : height / d : depth

mep ATV 11 flash corAng 10/07/02 13:24 Page 8

Page 8: Real efficiency at a reduced size!Altivar 68 75 to 630 kW Altivar 58 0.37 to 75 kW Altivar 38 0.75 to 315 kW Altivar 11 0.18 to 2.2 kW Variable speed drives Increase your performance

A comprehensive rangeof Motor Starters

Differentialcircuit-breakers,

Contactors.

A unique partner,a global presence

Constantly available, worldwide.With more than 5000 points of sale in 130 countries, you canbe sure to find the range of products which is right for youand which complies totally with the standards in the countryin which they are to be used.

Schneider Electric ServicesOur services, near you, wherever you are.Our experts are at your disposal, working with you to designyour customised solution.Our aim: to optimise your installations and improve yourindustrial performance.

Owing to changes in standards and equipment, the characteristics given in the text

and images in this document are not binding until they have been confirmed with us.

Production: 3000 NR

Photos: Schneider Electric - ImageBank

89 boulevard Franklin Roosevelt

92504 Rueil Malmaison Cedex

FRANCE

http://www.schneider-electric.fr

06/2002038996

Head office

Schneider Electric Industries S.A.S.

VV

DE

D10

2051

EN

Circuit-breakers,

Altivar 6875 to 630 kW

Altivar 580.37 to 75 kW

Altivar 380.75 to 315 kW

Altivar 110.18 to 2.2 kW

Variable speed drivesIncrease your performance withthe associated TeSys components*

Soft start - soft stop units

LH46 to 85 A

Altistart 4817 to 1200 A

*For further details on product combinations,please refer to our catalogue.

Altivar 280.37 to 15 kW

mep ATV 11 flash corAng 10/07/02 13:23 Page 2


Recommended