+ All Categories
Home > Documents > ReaMetrix-CatalogNew

ReaMetrix-CatalogNew

Date post: 18-Nov-2014
Category:
Upload: reametrix
View: 107 times
Download: 2 times
Share this document with a friend
Popular Tags:
10
1585 Industrial Road San Carlos, CA 94070 USA Phone : +1 650 620 9253 Fax : +1 650 620 0093 50-B, II Phase Peenya Industrial Area Peenya, Bangalore 560058, India Ph: +91-80-28378693/5 Fax: +91-80-41172451 E-mail: [email protected] Web: www.reametrix.com “ReaMetrix help us in keeping our commitment in offering tests at affordable costs especially HIV. We have so far conducted hundreds of tests and have obtained accurate and reproducible results. The availability of these reagents at this very af- fordable price point has allowed us to significantly reduce the cost of these tests to the patient.” Dr. Sujay Prasad, Director, Anand Diagnostics “With the new concept of dried reagents a sample can be added to the reagent tube where the sample is collected. The sample integrity is maintained upto a week at temperatures upto 40°C. This gives us tremendous flexibility in the way samples can be handled.’ Dr.Anjali Kale, Head Reference Laboratory, Dr Lal Pathlabs ISO 9001:2008 certified company www.reametrix.com ReaMetrix Accelerating Innovation
Transcript
Page 1: ReaMetrix-CatalogNew

1585 Industrial RoadSan Carlos, CA 94070 USAPhone : +1 650 620 9253Fax : +1 650 620 0093

50-B, II PhasePeenya Industrial AreaPeenya, Bangalore 560058, IndiaPh: +91-80-28378693/5Fax: +91-80-41172451

E-mail: [email protected]: www.reametrix.com

“ReaMetrix help us in keeping our commitment in offering tests at affordable costs especially HIV. We have so far conducted hundreds of tests and have obtained accurate and reproducible results. The availability of these reagents at this very af-fordable price point has allowed us to significantly reduce the cost of these tests to the patient.”

Dr. Sujay Prasad, Director, Anand Diagnostics

“With the new concept of dried reagents a sample can be added to the reagent tube where the sample is collected. The sample integrity is maintained upto a week at temperatures upto 40°C. This gives us tremendous flexibility in the way samples can be handled.’

Dr.Anjali Kale, Head Reference Laboratory, Dr Lal Pathlabs

ISO 9001:2008 certified company

www.reametrix.com

ReaMetrixAccelerating Innovation

Page 2: ReaMetrix-CatalogNew

Company

ReaMetrix, Inc. is a next generation biotechnology company that was founded with the unique business model of using the “labor cost arbitrage” through India to create signifi-cant and sustainable “value arbitrage”. As with the early Silicon Valley entrepre-neurs, we are working to build a company culture that provides talented Indian scientists with an environment where they have freedom to exercise their train-ing, skills and imagination while building corporate value. Our egalitarian approach allows us to encourage and reward initiative throughout our organization. Our people are the key to our success.

“The challenge of technological inno-vation is to create solutions that are locally affordable and sustainable in the long run within the local macro-economic constraints. The solutions should permit generation of local economic activity that will reinforce long-term economic sustainability.”

Bala S. Manian, CEO ReaMetrix Inc.. Affordable Diagnostics—Chang-ing the Paradigm in India. Cytometry Part B (Clinical Cytometry) 74B (Suppl. 1):S117–S122 (2008)

Process is our Product

At ReaMetrix, we have built a world-class research and devel-opment facility in Bangalore, India with a primary focus of applying Six Sigma product de-velopment strategies to diagnos-tic and life science products. We believe that process control is a critical component of generating high quality data and products. Our corporate infrastructure is process-centric, and we live by our philosophy on a daily basis. Rigorous documentation, full audit trails, and a dedicated quality group result in high qual-ity products, and reproducible, trustworthy data. At ReaMetrix, Process is our Product.

ReaMetrix is committed to becoming the leading provider of high quality research and diag-nostic assay solutions resulting in a transformation of the cost opportunities available in India into value for both the biotech-nology and global health sectors.

Page 3: ReaMetrix-CatalogNew

HIV Immunophenotyping

Reagents for Diagnostic Use

Catalog Number

Product/ Reagent

Intended Use

Format Storage Kit Sizes

25118-00 Dry Tri T-STATCD3/CD4/CD8 Reagent *

Dry Room Temperature

50For determining absolute counts of human total T, helper/inducer & suppressor/cytotoxic T lymphocytes in erythrocyte-lysed whole blood

25197-00 Dry Tri T-STATCD3/CD4/CD45 Reagent

Dry Room Temperature

50For determining absolute lymphocyte count (ALC), percentages & absolute counts of hu-man total T and helper/inducer T lymphocytes in erythrocyte-lysed whole blood

25239-00 ReaPan 34845 Reagent

Dry Room Temperature

50For determining ALC, percentages and absolute counts of human total T, helper/inducer & Suppressor/cytotoxic T lymphocytes in eryth-rocyte-lysed whole blood

25244-00 ReaPan 3 4 G Reagent

Dry Room Temperature

50Reagent For determining absolute counts of human total T, helper/inducer T lymphocytes on Guava Platform

25332-00 ReaPan 3 8 G Reagent

Dry Room Temperature

50For determining absolute counts of human total T, suppressor/cytotoxic T lymphocytes on Guava Platform

25124-00 Rea T-Count CD4/CD3 & CD8/CD3 (Dual tube) Reagent

Dry Room Temperature

50For determining absolute counts of human to-tal T, helper/inducer & suppressor/cytotoxic T lymphocytes in erythrocyte-fixed whole blood on BD FACSCount™ platform

25242-00 Rea T Count CD4/CD3 (Single Tube) Reagent

Dry Room Temperature

50For determining absolute counts of human total T, helper/inducer T lymphocytes in erythrocyte-fixed whole blood on BD FACSCount™ platform

Decentralized Staining Concept

Blood samples from collection centres that operate in resource poor settings, age by the time as they are shipped to centralized testing facilities. CD receptors are known to undergo a process called “capping” (internalization of receptors), with sample ageing.

Dry reagents enable staining to be done in collection centres that typically have no electricity to run refrigeration units. Stained samples can then be transported without the need for cold chain.

The decentralized approach to sample processing mitigates the risk associated with variation in cell counts. Studies on samples stained and fixed using dry re-agents have shown that there is no drop in staining intensity or cell count upto 8 days when stored at room temperature.

Regulatory Status

ReaMetrix Reagents conform to highest international standards of quality. Most of the diagnostic reagents are CE marked and/or FDA cleared. For details, please contact us.

* For In Vitro Diagnostic Use in the United States

Page 4: ReaMetrix-CatalogNew

Reagents for Diagnostic Use

25238-00 ReaPan B27

Dry Room Temperature

25For detection of HLA-B27 antigen expression in erythrocyte-lysed whole blood (LWB) using flow cytometry

25323-00 ReaPan S34

Dry Room Temperature

25For enumeration of Hematopoietic stem cells CD34+ in human peripheral or mobilized blood samples, umbilical cord blood samples, bone marrow samples and leukapheresis samples by flow cytometry

25329-00 ReaPan Micro

Dry Room Temperature

50For screening of Urine samples for presence/absence of bacteria by flow cytometry

25108-00 ReaCountTubes

Dry Room Temperature

50Absolute Counting Fluorescent Beads-Provides absolute counts for immunophenotyping

Catalog Number

Product/ Reagent

Intended Use

Format Storage Kit Sizes

Hematopoietic CD34+ Stem Cell Enumeration

Presence/Absence test for Bacteria in Urine

ReaCount Tubes

HLA B-27 Typing

ReaPan S34: Ease in Workflow

ReaMetrix Stem cell enumera-tion reagents are provided in one ready-to-use reagent dried tube. The assay just needs addition of sample, simplifying sample preparation. Incubation time is 30 minutes, speeding time to results; a boon to diagnostic labs that process multiple samples simulta-neously. Predispensed fluorescence reference beads included in the reagent tube, ensure accurate enumeration of CD34+ cells interest. The result: more efficient workflow and greater confidence in results.

ReaMetrix HLA B27 reagent: Enabling Reduced HLA-B7 Cross Reactivity

The only existing flow cytometry based reagent featuring two antibodies against the HLA-B27 antigen. The result: increased Sensitivity. The reagent use anti-B7 antibody against HLA-B7 antigen, which ensures minimal cross reac-tivity thus reducing the number of false positives. The result: higher Specificity. The reagent uses built-in intensity controls in each test making the assay highly ro-bust and independent of external standards.

Regulatory Status

ReaMetrix Reagents conform to highest international standards of quality. Most of the diagnostic reagents are CE marked and/or FDA cleared. For details, please contact us.

Page 5: ReaMetrix-CatalogNew

Reagents for Research Use

25347-00 Anti CD3-Atto488/CD4-PE-DyLight 594/CD8-PE/CD45-PerCP Reagent

Dry Room Temperature

50For determining ALC, percentages and absolute counts of human total T, helper/inducer & Suppressor/cytotoxic T lymphocytes in erythrocyte-lysed whole blood on Beckman Coulter 4 colour EPICS-XL Instrument

25384-00 Anti CD45-Atto 488/ CD4-PE reagent

Dry Room Temperature

50For determining ALC, percentages and absolute counts of human helper/inducer T lympho-cytes in erythrocyte-lysed whole blood

25348-00 Anti CD41-Atto488 & CD61-Atto488 reagent with Absolute Counting Beads

Dry Room Temperature

50For determining absolute counts of human platelets in stained-fixed whole blood

25387-00 7-Amino-actinomycin D ( 7-AAD) nucleic acid dye ready-to-use solution with Absolute Counting Beads

Liquid 2-8 ° C 25For enumeration of residual leucocytes in Leuco reduced blood products

25381-00 Anti CD235ab-Dy649/Thiazole Orange re-agent with Absolute Counting Beads

Dry Room Temperature

50For determining percentages and absolute counts of human reticulocytes and absolute count of erythrocytes using Flow Cytometry

Catalog Number

Product/ Reagent

Typical Usage

Format Storage Kit Sizes

Human Platelets Enumeration

Residual Leucocytes Enumeration

Human Reticulocyte Enumeration

HIV Immunophenotyping

Page 6: ReaMetrix-CatalogNew

Reagents for Research Use

CR70002-00

CR70003-00

CR70004-00

CR70005-00

CD45-PerCP/ CD55-PE

CD45-PerCP/ CD59-Atto488

CD45-PerCP/ MIgG1,k-PE

CD45-PerCP/ MIgG2a,k-Atto488

Liquid 2-8 °C 25For Paroxysmal Nocturnal Haemo-globinuria Diagnosis by Granulocytes and/or Erythrocyte Analysis using Flow Cytometry

25341-00 Anti CD45-Atto488/CD14-PE reagent with Absolute Counting Beads

Liquid 2-8 ° C 25For determining absolute counts & percent-ages of human monocytes in erythrocyte-lysed whole blood

CR70001-00 Anti CD11b-Atto488/CD64-PE/CD15-PE-Dy649 reagent with Absolute Counting Beads

Liquid 2-8 ° C 25For measurement of neutrophil CD64 expres-sion on human blood leukocytes which cor-relates with the presence of infection or sepsis in humans

Catalog Number

Product/ Reagent

Typical Usage

Format Storage Kit Sizes

Human Monocytes Enumeration

Sepsis Panel

Paroxysmal Nocturnal Haemoglobinuria (PNH) typing

Page 7: ReaMetrix-CatalogNew

Reagents for Research UseReaMetrix Multicolor Immunophenotyping Reagents (Leukemia-Lymphoma Panel)

Excitation Laser (nm)

Emission Maximum (nm)

488 488 , 532 488 , 532 488 , 532 488 595, 633, 635, 647

595, 633, 635, 647

488, 532, 561523 578 618 676 678

660 660785

AntibodiesAtto-488(FITC Equivalent)

Phycoerythrin (PE)

PE-DyLight 594(PE-Texas Red equivalent)

PE-Dyomics 649(PE-Cy5 equivalent)

PerCP APCPE-HiLyte 750(PE-Cy7 equivalent)

APC-HiLyte 750(APC-Cy7 equivalent)

CD2

CD3

CD4

CD5

CD7

CD8

CD10

CD11b

CD13

CD14

CD15

CD16

CD19

CD20

CD22

CD23

CD25

CD33

CD34

CD36

CD38

CD41

CD45

25802-01

25803-01

25804-01

25805-01

25807-01

25808-01

25810-01

25811-01

25813-01

25814-01

25815-01

25816-01

25819-01

25820-01

25822-01

25823-01

25825-01

25833-01

25834-01

25835-01

25838-01

25841-01

25845-01

25802-02

25803-02

25804-02

25805-02

25807-02

25808-02

25810-02

25811-02

25813-02

25814-02

25815-02

25816-02

25819-02

25820-02

25822-02

25823-02

25825-02

25833-02

25834-02

25835-02

25838-02

25841-02

25845-02

25802-08

25803-08

25804-08

25805-08

25807-08

25808-08

25810-08

25811-08

25813-08

25814-08

25815-08

25816-08

25819-08

25820-08

25822-08

25823-08

25825-08

25833-08

25834-08

25835-08

25838-08

25841-08

25845-08

25802-03

25803-03

25804-03

25805-03

25807-03

25808-03

25810-03

25811-03

25813-03

25814-03

25815-03

25816-03

25819-03

25820-03

25822-03

25823-03

25825-03

25833-03

25834-03

25835-03

25838-03

25841-03

25845-03

25802-04

25803-04

25804-04

25805-04

25807-04

25808-04

25810-04

25811-04

25813-04

25814-04

25815-04

25816-04

25819-04

25820-04

25822-04

25823-04

25825-04

25833-04

25834-04

25835-04

25838-04

25841-04

25845-04

25802-05

25803-05

25804-05

25805-05

25807-05

25808-05

25810-05

25811-05

25813-05

25814-05

25815-05

25816-05

25819-05

25820-05

25822-05

25823-05

25825-05

25833-05

25834-05

25835-05

25838-05

25841-05

25845-05

25802-06

25803-06

25804-06

25805-06

25807-06

25808-06

25810-06

25811-06

25813-06

25814-06

25815-06

25816-06

25819-06

25820-06

25822-06

25823-06

25825-06

25833-06

25834-06

25835-06

25838-06

25841-06

25845-06

25802-07

25803-07

25804-07

25805-07

25807-07

25808-07

25810-07

25811-07

25813-07

25814-07

25815-07

25816-07

25819-07

25820-07

25822-07

25823-07

25825-07

25833-07

25834-07

25835-07

25838-07

25841-07

25845-07

Pack Sizes

Using its own unique dried down reagent technology, ReaMetrix can mix and match antibodies and fluorophores to create specific multicol-or dried down L-L panels of reagents as per customer’s requirements.

Minimum pack size depends on

CUSTOM CONJUGATION SERVICES

Antibody-dye combination chosen

Page 8: ReaMetrix-CatalogNew

Excitation Laser (nm)

Emission Maximum (nm)

488 488 , 532 488 , 532 488 , 532523 578 618 676

AntibodiesAtto-488(FITC Equivalent)

Phycoerythrin (PE)

PE-DyLight 594(PE-Texas Red equivalent)

PE-Dyomics 649(PE-Cy5 equivalent)

CD55

CD56

CD59

CD61

CD64

CD73

CD79a

CD90

CD103

CD105

CD117

HLA-DR

Kappa

Lambda

IgM

TCR αβ

TCR γδ

MPO

FMC7

Mouse IgG1, κ

Mouse IgG2a, κ

Mouse IgG2b, κ

Mouse IgG3

25855-01

25856-01

25859-01

25861-01

25864-01

25873-01

25879-01

25890-01

25903-01

25905-01

25917-01

25750-01

25751-01

25752-01

25753-01

25754-01

25755-01

25756-01

25757-01

25758-01

25759-01

25760-01

25761-01

25855-02

25856-02

25859-02

25861-02

25864-02

25873-02

25879-02

25890-02

25903-02

25905-02

25917-02

25750-02

25751-02

25752-02

25753-02

25754-02

25755-02

25756-02

25757-02

25758-02

25759-02

25760-02

25761-02

25855-08

25856-08

25859-08

25861-08

25864-08

25873-08

25879-08

25890-08

25903-08

25905-08

25917-08

25750-08

25751-08

25752-08

25753-08

25754-08

25755-08

25756-08

25757-08

25758-08

25759-08

25760-08

25761-08

25855-03

25856-03

25859-03

25861-03

25864-03

25873-03

25879-03

25890-03

25903-03

25905-03

25917-03

25750-03

25751-03

25752-03

25753-03

25754-03

25755-03

25756-03

25757-03

25758-03

25759-03

25760-03

25761-03

488 595, 633, 635, 647

595, 633, 635, 647

488, 532, 561

678660 660

785

PerCP APCPE-HiLyte 750(PE-Cy7 equivalent)

APC-HiLyte 750(APC-Cy7 equivalent)

25855-04

25856-04

25859-04

25861-04

25864-04

25873-04

25879-04

25890-04

25903-04

25905-04

25917-04

25750-04

25751-04

25752-04

25753-04

25754-04

25755-04

25756-04

25757-04

25758-04

25759-04

25760-04

25761-04

25855-05

25856-05

25859-05

25861-05

25864-05

25873-05

25879-05

25890-05

25903-05

25905-05

25917-05

25750-05

25751-05

25752-05

25753-05

25754-05

25755-05

25756-05

25757-05

25758-05

25759-05

25760-05

25761-05

25855-06

25856-06

25859-06

25861-06

25864-06

25873-06

25879-06

25890-06

25903-06

25905-06

25917-06

25750-06

25751-06

25752-06

25753-06

25754-06

25755-06

25756-06

25757-06

25758-06

25759-06

25760-06

25761-06

25855-07

25856-07

25859-07

25861-07

25864-07

25873-07

25879-07

25890-07

25903-07

25905-07

25917-07

25750-07

25751-07

25752-07

25753-07

25754-07

25755-07

25756-07

25757-07

25758-07

25759-07

25760-07

25761-07

Pack Sizes

This concept is suited to diagnostic labs that process multiple samples simultaneously. This approach can be used to standardize panels (anti-bodies and fluorophores) across various laboratories so that there can be an unbiased discussion of the results of immunophenotyping.

Reagents for Research UseReaMetrix Multicolor Immunophenotyping Reagents (Leukemia-Lymphoma Panel)

CUSTOM CONJUGATION SERVICES

Minimum pack size depends on Antibody-dye combination chosen

Page 9: ReaMetrix-CatalogNew

ReagentAccessories

Catalog Number

Product/ Reagent

Typical Usage

Format Storage Kit Sizes

Accessories for Diagnostic Use

25237-00 ReaLyse lysing Solution (10X Concentrate)

Liquid Room Temperature

50 ml

Erythrolytic reagent intended for lysing red blood cells to enable a lyse-no wash protocol

25326-00 ReaFix Liquid Room Temperature

25325-00 ReaFix Fixative Solution (5% Formaldehyde)

Liquid Room Temperature

50 ml

Fixative solution intended for the fixation of cell preparations

ReaFlow LiquidTemperature

4 cans (each 5 l)

Buffered sheath fluid meant for use on most flow cytometer systems.

50 ml

25386-00 Room

(Diluent Solution)Diluent solution used for dilution of Fixative solution

Page 10: ReaMetrix-CatalogNew

Other Services

Design of Research Reagents

Custom Conjugation Services

Custom Cell Line Development Services

Bead Based FLISA Assay Bead Based FLISA for Quantita-tive Estimation of Antigen Con-centrations by Flow Cytometry technique

ReaMetrix offers custom conjugation services in Antibody, proteins, Chemokines, micro and nanosphere conjugations with fluorophores and Quantum dots

ReaMetrix offers development of stable cell lines expressing protein of interest at high, homogenous levels

Detection of PCR Products on Flow Cytometry Assay

Qualitative Detection of PCR Products on Flow Cytometry

ReaMetrix can customize Antibody-Dye combinations to meet your requirements

We provide a complete development solution from, the cloning of novel genes into suitable expression vectors, transfection optimization, stable clone isolation


Recommended