+ All Categories
Home > Documents > Rebuild & Extension

Rebuild & Extension

Date post: 15-Apr-2022
Category:
Upload: others
View: 5 times
Download: 0 times
Share this document with a friend
6
GARAGE 178 ST. THOMAS WAY 25' NAVIGATION EASEMENT SIDE SETBACK 63'-10" 6'-0" 150.33' DRIVEWAY 37.01' 3' X 50' PUE 15.56' 19.38' B A C D N70º 62' E N02º 26' 36" E 133.8' S20º 00' E 95.5' 5 4 3 2 1 COURTYARD ENTRY 25'-0" OUTLINE OF ADDITIONS PER PLAN 8'-0" DECK Site Plan & Data A1.0 SYMBOLS SHEET INDEX AND NOTES A 1 1 A5 2 A6 1 A5 N S W E COLUMN/ GRID LINES DETAIL KEY (DETAIL 1 ON SHEET A5) DETAIL/AREA KEY (DETAIL 2 ON SHEET 6) DIMENSION LINE DISCONTINUITY WORK, CONTROL, OR DATUM POINT LOCATION OF POINT IF NOT CENTER OF SYMBOL ELEVATION GROUP ELEVATION PROJECT NORTH ARROW 1 STORAGE 101 A 1 NOTATION TO FACE/AREA REVISION AFTER BIDDING OR START OF CONSTRUCTION ROOM NAME ROOM NO. - FIRST DIGIT IS FLOOR NO. - IF USED SECTION (SECTION 1 ON SHEET A4) WINDOW DESIGNATION DOOR NUMBER (HARDWARE GROUP IN DOOR SCHEDULE) 1 A4 1 A3 GENERAL NOTES PLANNING DATA VICINITY MAP N.T.S. 1. ALL CONSTRUCTION TO CONFORM TO CODES AND MINIMUM STANDARDS OF: 2019 CALIFORNIA BUILDING STANDARD CODES California Code of Regulations (CCR), Title 24, Parts 1 through 12 2019 California Administrative Code: CCR, Part 1 Chapter 4 2019 California Building Code: CCR, Part 2 Volume 1 and 2 and Appendices G, H, I and J 2019 California Electric Code: CCR, Part 3 2019 California Mechanical Code: CCR, Part 4 Chapter 1 and Appendices A, B and D 2019 California Plumbing Code: CCR, Part 5 Chapter 1 Sections 101 & 108, Chapter 2 through 16 Appendix Chapter 1 Sections 101,102 & 103. Appendices A, D, G, I and K 2019 California Energy Code: CCR, Part 6 Chapters 1 through 9 and Appendix Chapter 1-A 2019 California Fire Code: CCR, Part 9 Chapter I Section 109, Chapters 2 through 47 and Appendix Chapter 1 Section 102 2. VERIFY EXISTING DIMENSIONS AND CONDITIONS ON SITE. CALLED-OFF DIMENSIONS TO TAKE PRECEDENCE OVER SCALED-OFF DIMENSIONS ARE FACE OF STUD UNLESS OTHERWISE NOTED. ANY ERRORS, OMISSIONS OR AMBIGUITIES IN THE DRAWINGS ARE TO BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MEANS, METHODS, TECHNIQUES AND SEQUENCES OF CONSTRUCTION . THE CONTRACTOR SHALL ALSO BE SOLELY RESPONSIBLE FOR ALL SAFETY PROGRAMS AND PROCEDURES DURING CONSTRUCTION . THE CONTRACTOR MUST PROVIDE ADEQUATE SHORING AND BRACING OF THE STRUCTURE DURING CONSTRUCTION AND SHALL MAINTAIN THE SHORING AND BRACING UNTIL THE NEW PERMANENT STRUCTURE CAN PROVIDE ADEQUATE VERTICAL AND LATERAL SUPPORT. 4. ALL MATERIALS AND EQUIPMENT ARE TO BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS . SITE PLAN A A1.0 SITE PLAN & NOTES A2.0 (N) FLOOR PLANS A3.0 (N) SECTIONS A3.1 (N) ELEVATIONS A9.0 (E) FLOOR PLANS (for reference) A9.1 (E) EXTERIOR ELEVATIONS (for reference) 1/8" = 1'-0" 0 2 8 16 OWNERS PROPOSE TO ADD AND REMODEL: 1. ADD 84 S.F. TO 1ST FLOOR FAMILY ROOM 2. ADD 675 S.F. MASTER SUITE AND DECK TO 2ND FLOOR W/ VAULTED CEILING. 3. THE ADDITION WILL HAVE A CLASS 'A' FIRE-RESISTANT SHINGLE ROOF. 4. A PITCHED SHINGLE ROOF WILL BE ADDED OVER THE (E) 2ND FLOOR FLAT ROOF. 5. THE ADDITION WALLS AND (E) WALLS WILL HAVE A CEMENT COMPOSITE SHINGLE STYLE, CLASS 'A' FIRE-RESISTANT. 6. (N) DOORS AND WINDOWS TO BE ANDERSON SERIES 100 FIBERGLASS COMPOSITE. 7. (N) TRIM TO BE 'PRE-PRIMED' PAINTED WOOD. 8. THE DESIGN HAS BEEN APPROVED BY THE PARADISE CAY HOA. 1st FLR. FAMILY RM. ADDITION (N) ROOF OVER (E) 2nd STORY ROOF SKY SKY SKY 2-STORY HOUSE 2nd STORY ADDITION 37º 54' 53" N X 12.2º25' 30" W PLANNING DATA FLOOR AREA 1ST STORY................................. 2ND STORY................................ GARAGE.................................... TOTAL ....................................... % OF SITE ................................. EXISTING ..........1715.0 ............736.0 ______359.0 ..........2810.0 ............23.5% PARCEL NO. .......................... 038-201-56 SITE AREA ............................ 11,952 S.F. YEAR BUILT .......................... 1972 ZONING ................................. BFC-RSP-5.8 SETBACKS............................... FRONT 6', SIDE 6'. STREET 6', REAR 25' HEIGHT LIMIT ......................... 26 FT. MAX. Neighborhood Association SITE COVERAGE .................... 40% MAX. FLOOR AREA RATIO (F.A.R.) . 50% MAX. WILDFIRE ZONE.................... NO FIRE SPRINKLERS................ NO ADDITION ...............83.0 .............602.0 ________ 0.0 .............685.0 ..............5.7% PERVIOUS & IMPERVIOUS AREA (FOOTPRINT) HOUSE ...................................... GARAGE.................................... COURTYARD & DRIVEWAY IMPERVIOUS TOTAL................ DECK & LANDSCAPE.............. BAY WATER PERVIOUS TOTAL.................... SITE TOTAL............................... EXISTING ..........1715.0 ............359.0 2216.0 ..........4290.0 ..........2757.0 4905.0 ..........7662.0 ..........11952.0 PROPOSED ..............83.0 ................0.0 0.0 ................0.0 ................0.0 ________0.0 ................0.0 ..............83.0 TOTAL ...........1798.0 ...........1338.0 ______ 359.0 ...........3495.0 ............29.2% TOTAL ..........1798.0 ............359.0 2216.0 ..........4373.0 ................0.0 ________0.0 ..........7662.0 ........12035.0 PAVING- IMPERVIOUS SURFACE LANDSCAPE LANDSCAPE- PERVIOUS SURFACE BUILDING- IMPERVIOUS SURFACE DECKING- PERVIOUS SURFACE BAY WATER- PERVIOUS SURFACE GSI TOPO 10' 10' EL. 30.5' EAVE TOP OF SEA WALL EL. 30.5' EAVE EL. 30.5' EAVE EL. 30.5' EAVE EL. 35.0' RIDGE GSI TOPO NOTES: 1. (E) SITE DRAINAGE SYSTEM TO REMAIN 2. 2ND STORY ADDITION- NO GRADING REQUIRED 3. 2ND STORY ADDITION- NO LANDSCAPING PLAN 4. 2ND STORY ADDITION- NO CHANGE TO (E) UTILITIES 5. NO CHANGE TO (E) SEWER SYSTEM 31 DEC '20 T24 Calcs 19 FEB '21 REVIEW Purvis-Cohl Addition 178 Saint Thomas Way Tiburon, California A.P. 038-201-56 OF 23 Digne de Lenea & Co. Design & Architecture Digne B. de Lenea Architect Lic. #C-18415 P.O. Box 1438 519 B Street #1 San Rafael, CA 94915 (415) 456-9566 [email protected] SHEET NO. ISSUE • DATE • DESCRIPTION C 2021 Digne de Lenea & Co. 6 APR '21 REVIEW !"# ! ! " !&"#$%()* !+ "- &(- )*"#$%&’(+ )* &’ !"#$%’ #’$+!%,- 2- 28- 23 REN. 15 JUL '21 PLANNING
Transcript
Page 1: Rebuild & Extension

GARAGE

178 ST. THOMAS WAY

25' NAVIGATION EASEMENT

SIDE SETBACK

63'-10"

6'-0"

150.

33'

DRIVEWAY

37.01'

3' X

50'

PUE

15.56'

19.38'

B

A

C

D

N70

º 62'

E

N02º

26'

36"

E

133.

8'

S20º 00' E95.5'

54321

COURTYARD

ENTRY

25'-0

"

OUTLINE OF ADDITIONSPER PLAN

8'-0"

DECK

Site Plan & Data

A1.0

SYMBOLS

SHEET INDEX AND NOTES

A

1

1A5

2A6

1A5

N

S

W E

COLUMN/ GRID LINES

DETAIL KEY(DETAIL 1 ON SHEET A5)

DETAIL/AREA KEY(DETAIL 2 ON SHEET 6)

DIMENSION LINE

DISCONTINUITY

WORK, CONTROL, OR DATUMPOINT

LOCATION OF POINT IF NOTCENTER OF SYMBOL

ELEVATION GROUP

ELEVATION

PROJECT NORTH ARROW

1

STORAGE101

A

1

NOTATION TO FACE/AREA

REVISION AFTER BIDDING ORSTART OF CONSTRUCTION

ROOM NAME

ROOM NO. - FIRST DIGIT ISFLOOR NO. - IF USED

SECTION(SECTION 1 ON SHEET A4)

WINDOW DESIGNATION

DOOR NUMBER(HARDWARE GROUPIN DOOR SCHEDULE)

1A4

1A3

GENERAL NOTES

PLANNING DATA

VICINITY MAP

N.T.S.

1. ALL CONSTRUCTION TO CONFORM TO CODES AND MINIMUM STANDARDS OF:2019 CALIFORNIA BUILDING STANDARD CODESCalifornia Code of Regulations (CCR), Title 24, Parts 1 through 122019 California Administrative Code: CCR, Part 1 Chapter 4 2019 California Building Code: CCR, Part 2 Volume 1 and 2 and Appendices G, H, I and J2019 California Electric Code: CCR, Part 32019 California Mechanical Code: CCR, Part 4 Chapter 1 and Appendices A, B and D2019 California Plumbing Code: CCR, Part 5 Chapter 1 Sections 101 & 108, Chapter 2 through 16 Appendix Chapter 1 Sections 101,102 & 103. Appendices A, D, G, I and K2019 California Energy Code: CCR, Part 6 Chapters 1 through 9 and Appendix Chapter 1-A2019 California Fire Code: CCR, Part 9 Chapter I Section 109, Chapters 2 through 47 and Appendix Chapter 1 Section 1022. VERIFY EXISTING DIMENSIONS AND CONDITIONS ON SITE. CALLED-OFF DIMENSIONS TO TAKEPRECEDENCE OVER SCALED-OFF DIMENSIONS ARE FACE OF STUD UNLESS OTHERWISE NOTED. ANY ERRORS, OMISSIONS OR AMBIGUITIES IN THE DRAWINGS ARE TO BEREPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MEANS, METHODS, TECHNIQUES ANDSEQUENCES OF CONSTRUCTION. THE CONTRACTOR SHALL ALSO BE SOLELY RESPONSIBLE FORALL SAFETY PROGRAMS AND PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR MUSTPROVIDE ADEQUATE SHORING AND BRACING OF THE STRUCTURE DURING CONSTRUCTION ANDSHALL MAINTAIN THE SHORING AND BRACING UNTIL THE NEW PERMANENT STRUCTURE CANPROVIDE ADEQUATE VERTICAL AND LATERAL SUPPORT.

4. ALL MATERIALS AND EQUIPMENT ARE TO BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS .

SITE PLANA

A1.0 SITE PLAN & NOTES A2.0 (N) FLOOR PLANS

A3.0 (N) SECTIONSA3.1 (N) ELEVATIONS

A9.0 (E) FLOOR PLANS (for reference)A9.1 (E) EXTERIOR ELEVATIONS (for reference)

1/8" = 1'-0"0 2 8 16

OWNERS PROPOSE TO ADD AND REMODEL:

1. ADD 84 S.F. TO 1ST FLOOR FAMILY ROOM

2. ADD 675 S.F. MASTER SUITE AND DECK TO 2ND FLOOR W/ VAULTED CEILING.

3. THE ADDITION WILL HAVE A CLASS 'A'FIRE-RESISTANT SHINGLE ROOF.

4. A PITCHED SHINGLE ROOF WILL BE ADDED OVER

THE (E) 2ND FLOOR FLAT ROOF.

5. THE ADDITION WALLS AND (E) WALLS WILL HAVE A CEMENT COMPOSITE SHINGLE STYLE, CLASS 'A' FIRE-RESISTANT.

6. (N) DOORS AND WINDOWS TO BE ANDERSON SERIES 100 FIBERGLASS COMPOSITE.

7. (N) TRIM TO BE 'PRE-PRIMED' PAINTED WOOD.

8. THE DESIGN HAS BEEN APPROVED BY THE PARADISE CAY HOA.

1st FLR. FAMILY RM. ADDITION

(N) ROOF OVER (E) 2nd STORY ROOF

SKY

SKY

SKY

2-STORYHOUSE

2nd STORY ADDITION

37º 54' 53" N X 12.2º25' 30" W

PLANNING DATA

FLOOR AREA

1ST STORY.................................2ND STORY................................ GARAGE....................................TOTAL .......................................

% OF SITE .................................

EXISTING

..........1715.0

............736.0______359.0..........2810.0

............23.5%

PARCEL NO. .......................... 038-201-56SITE AREA ............................ 11,952 S.F. YEAR BUILT .......................... 1972

ZONING ................................. BFC-RSP-5.8

SETBACKS............................... FRONT 6', SIDE 6'. STREET 6', REAR 25'HEIGHT LIMIT ......................... 26 FT. MAX. Neighborhood AssociationSITE COVERAGE .................... 40% MAX. FLOOR AREA RATIO (F.A.R.) . 50% MAX.

WILDFIRE ZONE.................... NOFIRE SPRINKLERS................ NO

ADDITION

...............83.0

.............602.0________ 0.0.............685.0

..............5.7%

PERVIOUS & IMPERVIOUS AREA (FOOTPRINT)HOUSE ......................................GARAGE....................................COURTYARD & DRIVEWAY IMPERVIOUS TOTAL................

DECK & LANDSCAPE..............BAY WATER PERVIOUS TOTAL....................

SITE TOTAL...............................

EXISTING

..........1715.0

............359.0 2216.0..........4290.0

..........2757.0 4905.0..........7662.0

..........11952.0

PROPOSED

..............83.0

................0.0 0.0................0.0

................0.0________0.0................0.0

..............83.0

TOTAL

...........1798.0

...........1338.0______ 359.0...........3495.0

............29.2%

TOTAL

..........1798.0

............359.0 2216.0..........4373.0

................0.0________0.0..........7662.0

........12035.0

PAVING- IMPERVIOUS SURFACE

LANDSCAPE

LANDSCAPE- PERVIOUS SURFACE

BUILDING- IMPERVIOUS SURFACE

DECKING- PERVIOUS SURFACE

BAY WATER- PERVIOUS SURFACE

GSI TOPO

10'

10' EL. 30.5'EAVE

TOP OF SEA WALL

EL. 30.5'EAVE

EL. 30.5'EAVE

EL. 30.5'EAVE

EL. 35.0'RIDGE

GSI TOPO NOTES:

1. (E) SITE DRAINAGE SYSTEM TO REMAIN

2. 2ND STORY ADDITION-NO GRADING REQUIRED

3. 2ND STORY ADDITION-NO LANDSCAPING PLAN

4. 2ND STORY ADDITION-NO CHANGE TO (E) UTILITIES

5. NO CHANGE TO (E) SEWER SYSTEM

31 DEC '20 T24 Calcs

19 FEB '21 REVIEW

Purv

is-C

ohl A

dditi

on17

8 Sa

int T

hom

as W

ayTi

buro

n, C

alif

orni

aA

.P. 0

38-2

01-5

6

OF 23

Dignede Lenea

& Co.Design & Architecture

Digne B. de LeneaArchitect Lic. #C-18415

P.O. Box 1438519 B Street #1

San Rafael, CA 94915(415) 456-9566

[email protected]

SHEET NO.

ISSUE • DATE • DESCRIPTION

C 2021Digne de Lenea & Co.

6 APR '21 REVIEW

30'-6"

45'-8"

39'-1"

AVG

. NE

IGH

BO

R'S

SE

TBA

CK

30'-6

" + 4

5'-8

" = 7

6'-2

" ÷ 2

=

50'-0"

25 APR '19

22 JUN '19

1 JUL '19

13 JAN '20

27 MAY '20

13 SEP '20

26 OCT '20

������

��������������

���� �� �������������������

������� �

2- 28-23REN.

15 JUL '21 PLANNING

Page 2: Rebuild & Extension

A2.0

(N) & RemodeledFloor Plans

0 1 4 81/4" = 1'-0"A FIRST FLOOR IMPROVEMENT PLAN

AA10

0 1 4 81/4" = 1'-0"B SECOND FLOOR IMPROVEMENT PLAN

(N) STRUCT. BEAM

PANTRY

OFFICE/BDRM.#4NO WORK

LIVINGNO WORK

LNDY.NO WORK

ENTRY

FAMILYREMODEL

CLCL

CL

BATH#3NO WORK

W

D

FAU

MAIN DECK

KITCHENREMODEL

TANKLESSW.H.

PNL.

UP

HALLNO WORK

AA3.0

AA3.0

A3.0B

QU

EEN

60x8

0

DININGREMODEL

BDRM#3NO WORK

28'-0

"

25'-1"

FAMILY ROOMAPPROX. 84 S.F.

1 3 4 52

3'-1

" DN.

BDRM.#2NO WORK

BATH#2NO WORK

W.I.C.NO WORK

W.I.C.NO WORK

STOR.

SHWR.

DECKNO WORK

ATTICA

A3.0A

A3.0HALLNO WORK

KIN

G76

x80

KING76x80

(N) M. BATH#1

(N) M. BDRM.#1(N) W.I.C.

6'-1

0"

(N) DECK

VAULTED CEIL'G.CPT.

WALLS TO 8'

LONG VIEW OFWATERWAY

21'-8"

3'-6" ± 13'-0"

6'-1

"3'

-1"

DOG DOOR

4'-2

"

25x28= 700 S.F.

T.B.

RAIN DOME IN TILE CEIL'G.

1/2" TEMP. GLASS RAIL'G.ON CURB

UNDERMOUNT SPA W/DECK SURROUND

2X4 WALL TO ROOF

UP

(N) SGD

BOW GABLE RIDGE ABOVE

CURBLESS SHOWER

GAS FIREPLACE W/POWER VENT

(N) W.I.C.

4-PANEL SGD

(E)D

(E)W

(E)W

22D26D

APPROX. 675 S.F. ADDITION

A3.0B

21'-8"

ADDITION ABOVE

2'-6

"

13'-5

"

SHWR.

WC

FIREPLACE REVISED TO GAS W/ POWERVENT

0 +1 +2

(E) 2X4 WALLS REBUILT W/ 2X6

9'-1

0"

COL.& BM.BELOW

SIDE DECK

WALL BELOW

ROOF ABOVE

9'-0

"

1 OF 3 SKYLIGHTS

SKY.

14W

16W

22W 20

W

15W

17W

18W

SKY.

13W

12W

10W

22D24D

SKY.

22D 21

D

22D23D

20D

22D27D

22D25D

1 3 4 52

2A6.3

2A6.2

2A6.0

1A6.3

3A6.3

2A6.0

3'-0

"

11'-1"

30.0°

4'-3" SILL

2'-2"

19W

5'-6

"

SPA

21W

1A6.0

A3.0B

19'-4" ±

10D

DEMO WALL

(N) HOOD OVER (E) RANGE

6'-3"

4'-4

"

2X6 WALLS

1'-5"

--A--

(N) CANTILEVEREDFLOOR ABOVEALIGNED TO (E)

(N) S

TRU

CT.

BEA

M

(E) 2X4 WALLS

AA10

DA3.0

DA3.0

DA3.0

DA3.0

LWR

LWR

LWR

LWR

3'-2"

2X6

2X4

2X6

2X6

2X6

2X4

4'-1

"

2X4 WALL TOROOF

SCUPPER & D.S.

3'-3"

10'-9"

4-PANEL SLIDINGGLASS DOOR

D.S.

6A6.5

13'-9

"

F.O.S.

F.O.S.

CANTILEVER

DEMO

LINEN

--A--

8'-9"11'-8"

A

B

C

D

C

D

B

A

7A6.1

7A6.0

31 DEC '20 T24 Calcs

19 FEB '21 REVIEW

Purv

is-C

ohl A

dditi

on17

8 Sa

int T

hom

as W

ayTi

buro

n, C

alif

orni

aA

.P. 0

38-2

01-5

6

OF 23

Dignede Lenea

& Co.Design & Architecture

Digne B. de LeneaArchitect Lic. #C-18415

P.O. Box 1438519 B Street #1

San Rafael, CA 94915(415) 456-9566

[email protected]

SHEET NO.

ISSUE • DATE • DESCRIPTION

C 2021Digne de Lenea & Co.

6 APR '21 REVIEW

30'-6"

45'-8"

39'-1"

AVG

. NE

IGH

BO

R'S

SE

TBA

CK

30'-6

" + 4

5'-8

" = 7

6'-2

" ÷ 2

=

50'-0"

25 APR '19

22 JUN '19

1 JUL '19

13 JAN '20

27 MAY '20

13 SEP '20

26 OCT '20

������

��������������

���� �� �������������������

������� �

2- 28-23REN.

15 JUL '21 PLANNING

Page 3: Rebuild & Extension

A3.0

(N) Sections

A SECTION

B SECTIONC SECTION

1ST FLOOR

7'-7

"

1ST FLOOR

6'-0" 7'-9"7'-9"

21'-6"2'-6"

7'-8

"

1/4" = 1'-0"

1/4" = 1'-0"1/4" = 1'-0"

23'-0"

23'-0"

2'-6"

A CB D

7'-7

"

7"

DEMO

DEMO

DEMO

(E) HALL

(E) PNTY.

8'-0

"

(E) STOR.

(E) HALL

8'-1"

(E) M.BATH

12'-0"

8'-1"

12'-0"

WF

ST COL.

(E) 2ND FLOOR(N) 2ND FLOOR(N) 2ND FLOOR

(E) 2ND FLOOR(N) 2ND FLOOR

3'-6

"

(E) FLAT ROOF

7'-7

"

8'-7

"

7'-8

"

ATTIC

1 3 4 52

23'-0"

8'-0"

7"

2'-3"

T.O. BM.

ST COL.

1ST FLOOR

(E) 2ND FLOOR(N) 2ND FLOOR

MAX. HT. LIMIT

11'-7

"

312

3'-5

"

A CB D

8'-7

"8'-0"

12'-0"

B.O. BM.

T.O. BM.

1ST FLOOR

MAX. HT. LIMIT

(N) M.BDRM. (N) DECK

(N) 2ND FLOOR

D SECTION 1/4" = 1'-0"

3 4 5

(E) MECH.

DEMO

EL. 35.0'RIDGE

EL. 10.0'TOPO

20'-6

"

25'-0

"

12'-0"

EL. 30.5'EAVEEL. 30.5'

EAVE

EL. 10.0'TOPO

DEMO ROOF

(N) PITCHED ROOF OVER (E) FLAT ROOF

31 DEC '20 T24 Calcs

19 FEB '21 REVIEW

Purv

is-C

ohl A

dditi

on17

8 Sa

int T

hom

as W

ayTi

buro

n, C

alif

orni

aA

.P. 0

38-2

01-5

6

OF 23

Dignede Lenea

& Co.Design & Architecture

Digne B. de LeneaArchitect Lic. #C-18415

P.O. Box 1438519 B Street #1

San Rafael, CA 94915(415) 456-9566

[email protected]

SHEET NO.

ISSUE • DATE • DESCRIPTION

C 2021Digne de Lenea & Co.

6 APR '21 REVIEW

30'-6"

45'-8"

39'-1"

AVG

. NE

IGH

BO

R'S

SE

TBA

CK

30'-6

" + 4

5'-8

" = 7

6'-2

" ÷ 2

=

50'-0"

25 APR '19

22 JUN '19

1 JUL '19

13 JAN '20

27 MAY '20

13 SEP '20

26 OCT '20

������

��������������

���� �� �������������������

������� �

2- 28-23REN.

15 JUL '21 PLANNING

Page 4: Rebuild & Extension

A CB D

A3.1

(N) Elevations

2 WEST ELEVATION3 NORTH ELEVATION 1/4" = 1'-0"1/4" = 1'-0"

7'-1

1"13

'-6"

T.O. CEIL'G.

F.F.L.

4 SOUTH ELEVATION 1/4" = 1'-0"

F.F.L.

2'-7

"

1 ENTRY/ EAST ELEVATION

7'-7

"7'

-7"

T.O. CEIL'G.

1/4" = 1'-0"

F.F.L.

8

12

F.F.L.

F.F.L.

2nd FLR. ADDITION

ADDITIONADDITION

ADDITION BEYOND

BOW SHAPE RAKE

(N) DECK & SLIDING DRS. ON BIAS

(N) FAMILY ROOMADDITION

REPLACE WD. ROOFSHINGLES W/(N) CLASS 'A' COMP.ROOF

(N) RAISED HIPROOF OVER (E) FLAT ROOF(N) BOW GABLE ENDS

1 3 4 52

1345 2

20D

22'-5"

22'-5"

F.F.L.

REPLACE WD. WALLSHINGLES W/(N) CLASS 'A' CEMENT BD. SHINGLES

(N) TEMP. GLASS RAIL'G.

F.F.L.

ROOF HT.

(E) CEIL'G. HT.

AC BD

8'-0"

T.O. WALL

4.512

4.512

(N) SKYLIGHT

DOG DOOR

15W

14W14W

20W

22W

16W

17W

19W

312

312

312

20D

2'-6

"

1A1

1A6.2

1'-6"

1A1

VENT

FASCIA-GUTTER

11W

10D

CUT-DOWN CHIMNEY &CAP OPEN'G.

ATTIC VENT CALC:

ATTIC SPACE: 783 S.F. AREA ÷ 150 S.F. = 5.2 S.F. REQ'D. VENT AREAOR 5.2 X 144 IN .= 748 SQ. IN. REQ'D. VENT AREA

ATLAS RIDGE VENT 4'X12"= 18 N.F.A. IN.; 24' RIDGE ÷ 4 = 6; 6X108 S.Q. IN = 648

MASTER FLOW ROOF VENT: 16" SQ. IN.X 5 1/2"; 10" SIZE OPEN'G., 60 SQ. IN. NET; GALVANIZED LOUVER STYLE IN 3 LOCATIONS PER ROOF PLAN A2. 60" SQ. IN. X4 = 240 SQ. IN.

TOTALATLAS RIDGE VENT 648 SQ. IN. + MASTER FLOW VENT 240 SQ. IN. = 888 SQ. IN. OK; REQUIRED 748 SQ. IN.; PROVIDED VENT 888 SQ. IN. IS GREATER THAN 748 SQ. IN.

13W

12W

5A6.0

21W

(N) SCUPPER & D.S. OFF DECK

D.S.D.S. D.S. D.S.

D.S. D.S.D.S. D.S. D.S.D.S. D.S.

D.S. & SPLASH PANON ROOF

1A1

COLLECT D.S. TO SITE DRAINAGE SYSTEM

1A1

CONT. RIDGE VENT

10W

2A6.3

7'-5"

18W

EL. 35.0'RIDGE

20'-6

"

25'-0

"

EL. 30.5'EAVE

2X_ BARGE BD.

RAISED FLOOR

(N) WINDOWSPER PLAN

(E) DOOR & WINDOW

EL. 10.0'TOPO

ADD

ITIO

N

31 DEC '20 T24 Calcs

19 FEB '21 REVIEW

Purv

is-C

ohl A

dditi

on17

8 Sa

int T

hom

as W

ayTi

buro

n, C

alif

orni

aA

.P. 0

38-2

01-5

6

OF 23

Dignede Lenea

& Co.Design & Architecture

Digne B. de LeneaArchitect Lic. #C-18415

P.O. Box 1438519 B Street #1

San Rafael, CA 94915(415) 456-9566

[email protected]

SHEET NO.

ISSUE • DATE • DESCRIPTION

C 2021Digne de Lenea & Co.

6 APR '21 REVIEW

30'-6"

45'-8"

39'-1"

AVG

. NE

IGH

BO

R'S

SE

TBA

CK

30'-6

" + 4

5'-8

" = 7

6'-2

" ÷ 2

=

50'-0"

25 APR '19

22 JUN '19

1 JUL '19

13 JAN '20

27 MAY '20

13 SEP '20

26 OCT '20

������

��������������

���� �� �������������������

������� �

2- 28-23REN.

15 JUL '21 PLANNING

Page 5: Rebuild & Extension

A9.0

(E) Floor Plans

0 1 4 81/4" = 1'-0"A (E) FIRST FLOOR PLAN

14'-2"

7'-6"

1'-2"

13'-3"

6'-9

"

12'-7"

3'-3

"4'

-0"

3'-2

"

12'-4"7'-9"15'-0" 14'-5"

21'-6

"

5'-5

"

3'-4"

5'-2

"

26'-6

"

10'-6

"

5'-0

"

13'-4

"

15'-7"

2'-0"

2'-0"

PANTRY

4/0

3/0

2/8

2/61/3

2/8

2/8

2/4

3/0

PR 2

468

2/6

2832 SHG

6040 SLD

BDRM#2

OFFICE/BDRM.#3 LIVING

LNDY

ENTRY

FAMILY

CLCL

CL

BATH#2

1'-3"

8'-0

"

W

D

FAU

5'-6

"

7'-10"

3'-9"

FTC 7'-7"

FTC 7'-11"

FTC

12'

-9"

8'

3'-3"

4'-6

"3'

-10"

13'-5

"

28'-3

"

2'-6

"

8'-2

"

2'-6

"

8'-0

"8'-0

"

8'-0"15'-6"

6'-9

"

FTC 7'-7"

FTC 7'-8"

5'-9"

3'-2"

14'-10"

6'-11"

4'-9" 1'-2"

4'-0

"

3'-1

"8'

-0"

8'-8

"3'

-3"

DN.

13'-5

"

9'-2

"2'

-0"

12'-4"

21'-6

"

8'-2

"

3'-3

"

6'-8

"

21'-8

"

1'-9"

2'-2

"

27'-4

"

0 1 4 81/4" = 1'-0"B (E) SECOND FLOOR PLAN

8'-0"

SKY.

M. BDRM.#1

M. BATH#1

5'-6"

8'-11"2/8

2/8

8'-0"

3'-0

"

3'-0

"

2'-0

"

1368

SH

G

1368

SH

G12068 4-PNL SLD

51040 SLD-FX-SLD

DECK

11'-0

"

1430

CAS

1430

CAS

3015

SLD

2030 SHG

4968 SLD

8'-0

"

PR. 2

468

FRH

7'-10 1/2"

4'-0

"

2030 SHG

9668 4-PNL-SGD

13'-0

"

16'-3 1/2"

A

C

B

D

1 3 4 52

A

C

B

D

1 3 4 52

KITCHENT.W.

PNL.

DINING

UP

HALL

W.I.C.

W.I.C.

STOR.

SHWR.

BALCONY

ATTIC

SPA

VAULTED CEIL'G.LEVEL CEIL'G./FLOOR ABOVE

7'-9

"7'

-9"

6'-0

"1/

040

40 S

LD

DOGDOOR

3'-5"

6'-8"

DOGDOOR

2'-2

"

2'-6"51068 SGD

1'-4"

HALL

5'-9"

15'-0

"

2832 SHG

FTC 7'-7"

10'-0

"

A

C

B

D

1 3 4 52

27'-4

"

11'-0

1/2

"

2'-6

"

30'-1

0"

63'-8"

8020 CAS-FIX-CAS

501040 SLD

4040 SLD

1468 FIX 1468 FIX

19'-0 1/2"

24'-9"

63'-8 1/2"

ATTIC

FLAT ROOF

31 DEC '20 T24 Calcs

19 FEB '21 REVIEW

Purv

is-C

ohl A

dditi

on17

8 Sa

int T

hom

as W

ayTi

buro

n, C

alif

orni

aA

.P. 0

38-2

01-5

6

OF 23

Dignede Lenea

& Co.Design & Architecture

Digne B. de LeneaArchitect Lic. #C-18415

P.O. Box 1438519 B Street #1

San Rafael, CA 94915(415) 456-9566

[email protected]

SHEET NO.

ISSUE • DATE • DESCRIPTION

C 2021Digne de Lenea & Co.

6 APR '21 REVIEW

30'-6"

45'-8"

39'-1"

AVG

. NE

IGH

BO

R'S

SE

TBA

CK

30'-6

" + 4

5'-8

" = 7

6'-2

" ÷ 2

=

50'-0"

25 APR '19

22 JUN '19

1 JUL '19

13 JAN '20

27 MAY '20

13 SEP '20

26 OCT '20

������

��������������

���� �� �������������������

������� �

2- 28-23REN.

15 JUL '21 PLANNING

Page 6: Rebuild & Extension

A9.1

(E) Elevations x

1 (E) ENTRY/ EAST ELEVATION

7'-1

1"

2 (E) DECK/ WEST ELEVATION

3 (E) NORTH ELEVATION7'

-7"

7'-7

"1'

-0"

7.8

12

7.8

12

7.8

12

T.O. CEIL'G.

SECOND FLOORT.O. CEIL'G.

FIRST FLOOR F.F.L.

2'-0

"

1/4" = 1'-0"

1/4" = 1'-0"

1/4" = 1'-0"

SECOND FLOORT.O. CEIL'G.

FIRST FLOOR

T.O. CEIL'G.

T.O. VAULTEDCEL'G.

7'-1

1"7'

-7"

SECOND FLOORT.O. CEIL'G.

FIRST FLOOR F.F.L.

S.F.L.

T.O. CEIL'G.

12'-5

"

T.O. VAULTEDCEL'G.

7.8

12

4 (E) SOUTH ELEVATION

7.8

12

1/4" = 1'-0"

12'-5

"

T.O. 2ND FL. DECK

2'-7

"

F.F.L.

12'-5

"

7'-1

1"

31 DEC '20 T24 Calcs

19 FEB '21 REVIEW

Purv

is-C

ohl A

dditi

on17

8 Sa

int T

hom

as W

ayTi

buro

n, C

alif

orni

aA

.P. 0

38-2

01-5

6

OF 23

Dignede Lenea

& Co.Design & Architecture

Digne B. de LeneaArchitect Lic. #C-18415

P.O. Box 1438519 B Street #1

San Rafael, CA 94915(415) 456-9566

[email protected]

SHEET NO.

ISSUE • DATE • DESCRIPTION

C 2021Digne de Lenea & Co.

6 APR '21 REVIEW

30'-6"

45'-8"

39'-1"

AVG

. NE

IGH

BO

R'S

SE

TBA

CK

30'-6

" + 4

5'-8

" = 7

6'-2

" ÷ 2

=

50'-0"

25 APR '19

22 JUN '19

1 JUL '19

13 JAN '20

27 MAY '20

13 SEP '20

26 OCT '20

������

��������������

���� �� �������������������

������� �

2- 28-23REN.

15 JUL '21 PLANNING


Recommended