+ All Categories
Home > Documents > recautions 1 Inspection BBefore and After...

recautions 1 Inspection BBefore and After...

Date post: 01-Dec-2018
Category:
Upload: dangduong
View: 213 times
Download: 0 times
Share this document with a friend
13
Safe CAUTIO ety P N: 1. C d 2. P p 3. D 4. N t 5. T P t 6. A 7. D d 8. W 9. B lo 10. D s 11. T S 12. P m h r 13. D t 14. T D c A 15. B d 16. C 17. T z z z recau Confirm that defective tra Protect the p patient. Do not disass Never immer he connecto The ultrason Please refer ransducer. A transducer Do not use a damage the When using t Be sure to u ocal regulat Do not use storage, it m The transduc Sterilization Please use t manual, othe have any q epresentativ Do not use p ransducer m Transducer d Do not soak chloride com Avoid contac Before conn diagnostic sy Clean and di To prevent th z direct su z sudden z dust or h ution t the transdu ansducer ma probe from t semble the t rse the tran or is not wat nic transduc r the ultras r cover must an aftermar system caus the transdu use ultrasou tions. the carrying ay become a cer and acce (or high-lev he disinfect erwise Mind questions, p ve. pre-lubricate material and damage may or saturate t mpounds, ace ct with solut necting or d ystem. sinfect the t he transduc unlight or X- changes in t heat genera ns ucer and cab ay cause elec the collision transducer t sducer conn terproof. Imm cer is only fo sonic diagn t be installed ket probe o sing a profo cer, wear ste nd gel. Plea g case for s a source of i essories sup vel disinfect) tion or steri dray will not please cont ed condoms damage ma y be caused transducers etone or for tions or coup disconnectin transducer b cer from bein -rays temperature ators ble work we ctric shock to n. A defectiv to avoid the nector into l mersion ma or use with ostic system d over the tr other than t und failure, erile gloves ase use the storing the infection. pplied with i ) before use ilization sol t be liable fo act Mindra s as a cover ay result. by inapprop s with solutio rmaldehyde pling gels co ng the tran before and a ng damaged e or excessiv ll before and o the patien ve transduce e possibility iquids such y cause elec the specifi m operation ransducer be hose specifi e.g. a fire in to prevent i ultrasound transducer. it are not de is required. lution that or damage c ay Custome r. Lubricant priate gel, d ons containi . ontaining m nsducer, fre after each ex d, do not use ve vibration d after each nt. er may cause of electric sh as water or ctric shock o ed ultrason n manual t efore perfor ied by Mind n the worst c infection. gel complia . If the carry elivered dis . recommend caused by o er Service D may not be etergent or ing alcohol, mineral oil or eeze or tur xamination. e it where it examinatio e electric sh hock. r disinfectan or malfunctio nic diagnost to select th rming exam dray. The pr case. ant with the ying case is infected or ded in this o other solutio Department e compatible cleanser: bleach, amm lanolin. rn off the will be expo on. A ock to the nt because on. ic system. he proper ination. robes may e relevant s used for sterilized. operator’s ons. If you t or sales e with the monium ultrasonic osed to: 1 1 Inspectio If any abn or sales re 1.1 Confirm t parts, or l CAUTI 1.2 Clean and CAUTIO 1.3 After turn 1. The a temp 2. The i 1.4 CAUTIO A legally Protectiv clinical sit Ins on before and normality is f epresentativ Check that there a looseness of ION: Tr is D Cleani d disinfect th ON: If you Check ning ON the p acoustic lens perature sho image must Utilizi ON: 1. B d o 2. T i 3. D t marketed tra e barriers m tuations whe pect d after use m found, imme e. k the Ex re no abnorm the acoustic ransducer ab found, imm epartment o ing the he transducer u don’t clean king aft power of the s of the transd uld be check not be abnor ng the Be sure to c during exam of the transd The cover co ndividuals. DO NOT use term of valid ansducer cov ay be requir ere infection ion B ust be perfor diately stop xterna malities of th lens, before bnormalitie mediately sto or sales repr e Trans r before and n and disinfe ter Tur e ultrasonic d ducer must n ked by hand. rmal while tu e Trans cover the tra mination. If t ducer cover ontains nat e an expired dity has exp ver must be i red to minim is a concern. Befor rmed as desc using the tra l Appe he transduce and after eac es may cause op using the resentative. sducer after each ex ect the trans rning o iagnostic sys not generate urning on the sducer ansducer wi the package may not be ural rubber transducer ired. nstalled over mize disease t . re an cribed below ansducer and earanc er surface or ch examinat e electric sho e transducer r xamination b sducer, it ma on the stem, perform e abnormal h e system. Cover ith a new (u e of a transd sufficient. D r latex and t cover. Befo r the transdu transmission nd Af w to ensure sa d contact MIN e of th cable cover ion. ock or injury r and contac by hospital re ay become a System m the followi eat while it is r unused) tran ducer cover DO NOT use talc that ca re using tra ucer before p n. Transducer fter U afe operation NDRAY Custo he Tran r, such as pe y to the pat ct your MIND egulation. a source of i m ing checks. s being used nsducer cov is open or b such a trans n cause alle ansducer cov performing in r covers are Use n of the trans omer Service nsduce eeling, cracks ient. If any a DRAY Custo nfection. . The transdu ver to preve broken, the s sducer cover ergic reactio vers, verify w tra-cavitary e available for sducer. Department er s, protruding abnormality omer Service ucer ent infection sterilization r. ons in some whether the examination r use with al t g y e n n e e . l
Transcript
Page 1: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Safe

CAUTIO

ety P

N: 1. Cd

2. Pp

3. D

4. Nt

5. TPt

6. A

7. Dd

8. W

9. Blo

10. Ds

11. TS

12. Pmhr

13. Dt

14. T

Dc

A

15. Bd

16. C

17. T

recauConfirm thatdefective tra

Protect the ppatient.

Do not disass

Never immerhe connecto

The ultrasonPlease referransducer.

A transducer

Do not use adamage the

When using t

Be sure to uocal regulat

Do not use storage, it m

The transducSterilization

Please use tmanual, othehave any qepresentativ

Do not use pransducer m

Transducer d

Do not soak chloride com

Avoid contac

Before conndiagnostic sy

Clean and di

To prevent th

direct su

sudden

dust or h

utiont the transdu

ansducer ma

probe from t

semble the t

rse the tranor is not wat

nic transducr the ultras

r cover must

an aftermarsystem caus

the transdu

use ultrasoutions.

the carryingay become a

cer and acce(or high-lev

he disinfecterwise Mind

questions, pve.

pre-lubricatematerial and

damage may

or saturate tmpounds, ace

ct with solut

necting or dystem.

sinfect the t

he transduc

unlight or X-

changes in t

heat genera

ns

ucer and cabay cause elec

the collision

transducer t

sducer connterproof. Imm

cer is only fosonic diagn

t be installed

ket probe osing a profo

cer, wear ste

nd gel. Plea

g case for sa source of i

essories supvel disinfect)

tion or steridray will notplease cont

ed condoms damage ma

y be caused

transducersetone or for

tions or coup

disconnectin

transducer b

cer from bein

-rays

temperature

ators

ble work wectric shock to

n. A defectiv

to avoid the

nector into lmersion ma

or use withostic system

d over the tr

other than tund failure,

erile gloves

ase use the

storing the infection.

pplied with i) before use

ilization solt be liable foact Mindra

s as a coveray result.

by inapprop

s with solutiormaldehyde

pling gels co

ng the tran

before and a

ng damaged

e or excessiv

ll before ando the patien

ve transduce

e possibility

iquids such y cause elec

the specifim operation

ransducer be

hose specifie.g. a fire in

to prevent i

ultrasound

transducer.

it are not deis required.

lution that or damage c

ay Custome

r. Lubricant

priate gel, d

ons containi.

ontaining m

nsducer, fre

after each ex

d, do not use

ve vibration

d after each nt.

er may cause

of electric sh

as water orctric shock o

ed ultrasonn manual t

efore perfor

ied by Mindn the worst c

infection.

gel complia

. If the carry

elivered dis.

recommendcaused by o

er Service D

may not be

etergent or

ing alcohol,

mineral oil or

eeze or tur

xamination.

e it where it

examinatio

e electric sh

hock.

r disinfectanor malfunctio

nic diagnostto select th

rming exam

dray. The prcase.

ant with the

ying case is

infected or

ded in this oother solutioDepartment

e compatible

cleanser:

bleach, amm

lanolin.

rn off the

will be expo

on. A

ock to the

nt because on.

ic system. he proper

ination.

robes may

e relevant

s used for

sterilized.

operator’s ons. If you t or sales

e with the

monium

ultrasonic

osed to:

 

1InspectioIf any abnor sales re

1.1Confirm tparts, or l

CAUTI

1.2Clean and

CAUTIO

1.3After turn

1. The atemp

2. The i

1.4CAUTIO

A legally Protectivclinical sit

Inson before andnormality is fepresentativ

Checkthat there alooseness of

ION: Tris D

Cleanid disinfect th

ON: If you

Checkning ON the p

acoustic lensperature sho

image must

UtiliziON: 1. B

do

2. Ti

3. Dt

marketed trae barriers mtuations whe

pectd after use mfound, immee.

k the Exre no abnormthe acoustic

ransducer abfound, imm

epartment o

ing thehe transducer

u don’t clean

king aftpower of the

s of the transduld be check

not be abnor

ng theBe sure to cduring examof the transd

The cover condividuals.

DO NOT useterm of valid

ansducer covay be requir

ere infection

ion Bust be perfordiately stop

xternamalities of th lens, before

bnormalitiemediately stoor sales repr

e Transr before and

n and disinfe

ter Ture ultrasonic d

ducer must nked by hand.

rmal while tu

e Transcover the tramination. If tducer cover

ontains nat

e an expired dity has exp

ver must be ired to minimis a concern.

Beforrmed as descusing the tra

l Appehe transduceand after eac

es may causeop using theresentative.

sducerafter each ex

ect the trans

rning oiagnostic sys

not generate

urning on the

sducer ansducer withe packagemay not be

ural rubber

transducer ired.

nstalled overmize disease t

.

re ancribed belowansducer and

earancer surface orch examinat

e electric shoe transducer

r xamination b

sducer, it ma

on the stem, perform

e abnormal h

e system.

Coverith a new (u

e of a transdsufficient. D

r latex and t

cover. Befo

r the transdutransmission

nd Afw to ensure sad contact MIN

e of th cable coverion.

ock or injuryr and contac

by hospital re

ay become a

Systemm the followi

eat while it is

r unused) tranducer cover DO NOT use

talc that ca

re using tra

ucer before pn. Transducer

fter Uafe operationNDRAY Custo

he Tranr, such as pe

y to the patct your MIND

egulation.

a source of i

m ing checks.

s being used

nsducer covis open or bsuch a trans

n cause alle

ansducer cov

performing inr covers are

Use n of the transomer Service

nsduceeeling, cracks

ient. If any aDRAY Custo

nfection.

. The transdu

ver to prevebroken, the ssducer cover

ergic reactio

vers, verify w

tra-cavitary eavailable for

sducer. Department

er s, protruding

abnormalityomer Service

ucer

ent infectionsterilizationr.

ons in some

whether the

examinationr use with al

t

g

y e

n n

e

e

. l

Page 2: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Method (fo

1. Place ano gel

2. Insert tbubble

3. Secure

4. Inspec

To ordToll-free wiToll-free FaDirect Dial: Fax: 319.24

2 After comphave been needle-guid

CAUTIO

NOTE: Aftedegrade thNOTE: DO temperatur

2.1 CPlease refer

1. Discon

2. Wear s

or reference o

an appropriatis used.

the transduces, and taking

e the cover w

t the cover to

der probe covthin the U.S. x: 877.329.24319.248.675

48.6660; E-ma

Cleapleting each

performed, ded bracket t

ON: 1. W

g2. A

r3 N

r the examine image quaNOT make

re may cause

Cleaninr to the instru

nnect the pro

sterile gloves

only):

te amount of

er into the cog care to avo

with the enclo

o ensure the

vers, contact & Canada: 80

482 57 (Internatioail: order@civ

aningexaminationbe sure to s

to becoming

When perforgloves. After disinferesidues. ChNo cleaning nation, wipe lity of the trathe probe t

e the probe to

ng uctions in the

obe from the

s to prevent i

f gel inside th

over. Pull covoid puncturin

osed elastic b

re are no hol

CIVCO comp00.445.6741,

onal) vco.com; Web

g andn, clean and sterilize the

g sources of i

rming clean

ection, rinseemical residand disinfeoff the ultra

ansducer. to become oo become de

e manual and

system.

nfection.

he cover or o

ver tightly ovng the cover.

bands.

es or tears.

pany: ,

bsite: www.c

d Disdisinfect (or needle-guidnfection. Ple

ning and dis

e the probedues on the pcting may re

asound gel t

overheated (eformed or d

d follow your

on the transd

ver transduce

ivco.com

sinfecsterilize) the

ed bracket. ase follow th

infection of

e thoroughlyprobe may besult in the phoroughly. O

(more than amaged.

r hospital po

ucer acoustic

er acoustic le

ctione probes as Fail to do so

he instruction

f the probe t

y with steribe harmful tprobe becomOtherwise, th

55°C) during

licy and proc

c lens. Poor i

ns to remove

n required. Who may resultns in the man

to prevent i

le water to to the humaming a sourche ultrasoun

g cleaning a

cedures for c

maging may

e wrinkles an

hen biopsy pt in the probnual for clean

infection, we

remove allan body. ce of infectiod gel may so

and disinfect

leaning.

y result if

nd air

procedures be and the ning.

ear sterile

l chemical

on. olidify and

tions. High

 

3. Waswith

4. Dry t

2.2CAUTIO

1. Wea

2. Afterman

3. Rem

4. Wipe

NOTE: Do

2.31. Wea

2. Cleantrans

RefesolucablSoakthe sFollo

3. Rinseresidtrans

4. Wipeheat

h the transduh a soft ethyl

the transduc

Disinfe

ON:

r sterile glov

r you have finufacturer’s re

ove any resid

e off water on

o not spray th

Disinfer sterile glov

n the transdusducer.

er to the instrtion, methode near it intok the transdushortest timeow local regue the transdu

dues on it. Orsducer.

e off the wateting.

ucer with clecarbamate sp

cer using a ste

ecting

Use

es to prevent

nished cleaniecommende

due with a w

n the transdu

he strain relie

ectinges to prevent

ucer before d

ructions provd of disinfecto water or anyucer into the e recommendulations whenucer with ple, follow the r

er on the tran

C

ean water or sponge. Avoid

erile cloth or

g with S

e protective

t infection.

ing, spray or ed contact tim

water-moisten

ucer using ste

ef on the con

g by Imt infection.

disinfecting it

vided by the tion and diluty solution. disinfectant ded by the mn selecting anty of sterile

rinsing metho

nsducer with

Connector 

soapy water td using a bru

gauze after

Sprays

e eyewear

wipe the trame and mode

ned soft cloth

erile cloth or

nector end o

mersio

t. MINDRAY r

chemical mation and caut

solution for tmanufacturer

nd using the water (abouod recomme

h sterile cloth

to remove alush, because

rinsing. Do n

s or Wip

when disin

nsducer withe.

h on the tran

r gauze after

or the connec

on

recommends

anufacturer ctions during

the shortest r for soaking e disinfectantut 2 gallons) fended by the

h or gauze aft

l the foreignit may dama

not dry the tra

pes

nfecting us

h a disinfecta

sducer.

washing.

ctor.

s the followin

oncerning couse. Do not s

time the maCidex OPA ist. for at least 1 disinfectant

ter rinsing it.

St

n matters, or, age the transd

ansducer by

sing sprays

ant. Follow th

ng solutions

oncentrationsoak the tran

nufacturer res 12 minutes)

minute to ret manufactur

Do not dry t

train relief 

wipe the tranducer.

heating it.

s.

he disinfectan

to disinfect t

n of the disinfnsducer conn

ecommends .

move all cheer to rinse th

he transduce

nsducer

nt

the

fectant nector or the

(for example

emical he

er by

e,

Page 3: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

NOTE: Obserelief. NOTE: Repe

2.4 S1. Wear st

2. Clean thsolutio

Hydrog

Trade NaMinncare®

Sterilant

Glutar

Trade

Cidex Glutaraldeh

Refer tsolutio

Do not

erve the grap

eated disinfe

Sterilizterile gloves t

he transducens to sterilize

gen Peroxide

ame Cold 22%

4.5%

aldehyde-ba

e Name

Activatehyde Solution

to the instruon, method ot soak the tra

St

ph below car

ction will eve

ation (to prevent in

er before stere the transdu

e and Peroxy

Chemical N% Hydrogen P% Peroxyaceti

ased sterilizat

Chemi

d n

2.2-2.7%Glutarald

uctions provof sterilizationansducer con

rain relief 

refully to imm

entually dam

(Intra-onfection.

rilizing it. Disucer.

yacetic Acid -

Name Peroxide ic Acid

tion solution

ical Name

% dehyde

vided by then and dilutio

nnector or th

merse the tra

mage the prob

operat

infect the tra

based steriliz

Dilute the Immersed Please refesolution fo

Soak the trPlease refesolution fo

e chemical mn and cautioe cable near

ansducer. On

be, please ch

tive Us

ansducer if ne

zation solutio

sterilant withtime: 11 hou

er to the instor details.

ransducer inter to the instor details.

manufacturerons during us

it into water

nly soak parts

heck the prob

se)

ecessary. MIN

on

Proceh sterilized purs. Tempetructions pro

Proceto the activattructions pro

r concerningse.

or any solut

Probe han

s of the trans

be performan

NDRAY recom

edures urified watererature: 20℃ovided by th

edures ted solution fovided by th

g concentrati

ion.

ndle 

sducer below

nce periodica

mmends the

r (1:20). ℃-25℃. he manufactu

for 10 hours he manufactu

ion of the s

w the strain

ally.

following

urer of the

(20-25℃).urer of the

sterilization

 

Follo

3. Rinseresidtrans

4. Wipe

Before saSolution fBefore saleast 135

ow local regu

e the transduues on it. Or,

sducer.

e off the wate

afety and pefor at least 2

afety and pertimes (11 ho

ulations when

Immerse

cer with plen, follow the ri

er on the tran

rformance is17 times (10 rformance is ours for one t

n selecting a

e the intra-op

nty of sterile insing metho

nsducer with

s affected, inhours for onaffected, int

time).

nd using the

perative trans

water (aboutod recommen

sterile cloth

tra-operativee time).

tra-operative

e sterilization

sducer in the

t 2 gallons) fonded by the

or gauze afte

e probes can

e probes can

solution.

e solution (fo

or at least 1 msterilization s

er rinsing it. D

n be sterilized

be sterilized

or reference)

minute to remsolution man

Do not dry th

d by Cidex A

d by Minncar

move all chemnufacturer to

he transduce

Activated Glu

e COLD STER

mical o rinse the

r by heating.

utaraldehyde

RILANT for at

.

e

t

Page 4: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

A-1 conv

C5C5C6C6C7C13C3C6C35C65CSC5SC6SC865E65E65E

vex probe

Probes

-1s/C5-1E/C-2/C5-2s/C5-2E/C6-2 -2Gs/C6-2G-3E 1-3E/ C11-31/3C1s/3C15/3C5s/3C52/6C2P/6C2C20EA/35CC15EAV/655-1U/SC5-16-1U 8-2U EC10EA/65EL60EA EC10ED

es

Disinfe

s

C5-1U 5-2E

GE/C6-2GU

3s/C11-3U 1p 5A/3C5P 2s

C50EA/35C5C15EA

1E

EC10EB/65

ectants

50EB/35C50

EC10EC

0P

Ap

CLEA

NIS

EPT®

WIP

ES

ppend

CLEA

NIS

EPT

WIP

ES

mik

rozi

d® AF

Wip

es

b

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

dix A

Jum

bo

mik

rozi

d® Sens

itiv

e W

ipes

√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √

A Wi

PRO

TEXTM

DIS

INFE

CTA

NT

Wip

es

√√√ √√√√√√√ √√√

 

ipe D

Sani

-Clo

th® Pl

us

SON

OTM

ULT

RASO

UN

D

√ √ √ √ √ √ √ √ √ √ √ √ √

Disinf

SON

OTM

ULT

RASO

UN

D

WIP

ES

Ti

tlS

fW

i

√ √ √ √ √ √ √ √ √ √ √ √ √

fecta

Tris

tel S

urfa

ce W

ipes

Tris

tel P

re-C

lean

Wip

es

√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √

ants

Tris

tel S

pori

cida

l Wip

es

√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √

Tris

tel R

inse

Wip

es

√ √ √ √ √ √ √ √ √ √ √ √ √

UN

IVER

SAL

WIP

ES

√ √ √ √ √ √ √ √ √ √ √ √ √

Wip

'Ani

os p

rem

ium

Ult

raso

und

prob

e

√ √ √ √ √ √ √ √ √ √ √ √ √

pcl

eani

ng w

ipes

SPO

ROXI

I

√ √ √ √ √ √ √ √ √ √ √ √

Page 5: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

L7L9L1L1L1L1L1L1L1L1L1L1LML26L6L7L7L7L7L101050657575

A-2 linea

Probe

7-3/L7-3s/L9-3U/L9-3E/10-3E/L10-311-3U 11-4/L11-4s12-3/L12-3E12-4/L12-4s14-5W/L14-14-6/L14-6s14-6N/L14-614-6WE/L1416-4HE/L16M14-6E/LM20-5U/L20-5LE7/6LE7s/6LE5V/6LE5VL4/7L4s/7L4LT4/7LT4s/7L5/7L5P/7LL6/7L6s 0L4/10L4s 0L24EA 0L60EAV 5L50HAV 5L38EA/75L5L50EAV/75

ar probes

es

7-3E /L9-3s 3s

s E s -5WU s/L14-6P 6Ns/L14-6N4-6Ws/L14-6-4Hs/L16-4

M14-6s/LM165/L20-5s 6LE7P Vs/6LE5VP 4A/7L4P 7LT4P

L5s

L38EB/75L55LT38EA

s

NP/L14-6NE-6WU 4HU/L16-4H6-4U

53EA/75L60

Disinfect

E

Hs

0EA/75L38P

tants

P

CLEA

NIS

EPT® W

IPES

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √

mik

rozi

d® AF

Wip

es Ju

mbo

ikid

® Sit

iW

i

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √

mik

rozi

d® Sens

itiv

e W

ipes

PRO

TEXTM

DIS

INFE

CTA

NT

√ √√ √ √ √ √ √√ √ √ √ √√ √ √ √ √ √√ √ √√ √√ √ √ √ √√ √ √

Wip

es

Sani

-Clo

th® Pl

us

√ √ √ √

√ √

√ √ √ √

√ √ √ √

√ √

√ √ √ √ √ √ √ √ √

√ √ √ √ √

 

SON

OTM

ULT

RASO

UN

D

WIP

ES

Tris

telS

urfa

ceW

ipes

√ √√ √ √ √√ √√ √√ √√ √ √√ √√ √ √ √√ √ √ √ √√ √ √ √ √ √

Tris

tel S

urfa

ce W

ipes

Tris

tel P

re-C

lean

Wip

es

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

Tris

tel S

pori

cida

l Wip

es

Tris

tel R

inse

Wip

es

√ √√ √ √ √√ √√ √√ √ √ √√ √√ √ √ √ √ √ √ √√ √ √ √ √ √

UN

IVER

SAL

WIP

ES

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √

Wip

'Ani

os p

rem

ium

DI W

ater

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

Blea

ch 5

.25%

(10%

sol

utio

n)

Etha

nol 7

5%

Spor

ox II

√ √

Ult

raso

und

prob

e cl

eani

ng

wi p

es

Sani

-Clo

thA

F3

√ √ √ √ √ √ √ √ √ √ √ √ √ √

Met

riSp

onge

Prot

exU

ltra

Wip

es

√ √

√ √

Prot

ex U

ltra

Wip

es

Page 6: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

Table

A-3 othe

Pha

End

Pen

Bip

A-4 4D p

4CD4/D7-2/D6-2/D6-2ND8-2UD8-4UDE10-DE11-DE10-

er types o

Probes

ased

do-cavity

ncil

plane

probes

Probes

/4CD4A/4C/D7-2E/D7-2/D6-2P/D6-2NE U U -3/DE10-3E-3U/DE11-3-3WU

of probes

P4-2/P4-2P7-3/P7-3P10-4E/PP12-4/P12P2/2P2sSP5-1U/SV11-3/V1V11-3HUV10-4/106CV1/6CVCW2s/CW65EB10EACB10-4/C6LB7/6LB

CD4s 2s 2A/D6-2E

E/DE10-3U 3P/DE11-3s

2s/P4-2E/P43s/P7-3E/P7

P10-4s/P10-2-4s

s/2P2P SP5-1s/SP5-

1-3BE/V11/ V11-3HE/

0-4s/V10-4BV1s/6CV1P

W5s/CW5 A

CB10-4P/CBB7s/6LB7P

Disinfect

/DE11-3E

Dis

4-2NE/P4-27-3P/P7-3U-4U

-1E -3B/V11-3W

/V11-3Hs B/V10-4Bs/V

B10-4A/CB1

tants

CLEA

NIS

EPT®

WIP

ES

√√

sinfectants

2Ns U

WE/V11-3W

V10-4BP/V1

0-4E m

ikro

zid® A

F W

ipes

Ju

mbo

√ √ √ √

√ √

s

Ws/V11-3E

0-4P

Jum

bo

PRO

TEXTM

DIS

INFE

CTA

NT

Wip

es

√ √

CLEA

NIS

EPT®

WIP

ES

√ √ √ √ √

Sani

-Clo

th® Pl

us

SON

OTM

ULT

RASO

UN

D

√ √

mik

rozi

d® AF

Wip

es Ju

mbo

√ √ √ √

WIP

ES

Tris

telS

urfa

ceW

ipes

√ √

 

mik

rozi

d® Sens

itiv

e W

ipes

PRO

TEXTM

DIS

INFE

√ √ √

Tris

tel S

urfa

ce W

ipes

Tris

tel P

re-C

lean

√ √√ √

PRO

TEXTM

DIS

INFE

CTA

NT

Wip

es

Sani

-Clo

th® Pl

us

√ √ √ √ √ √√ √√ √√ √ √ √ √

Wip

es

Tris

tel S

pori

cida

l W

ipes

√ √√ √

SON

OTM

U

LTRA

SOU

ND

W

IPES

√ √ √ √ √ √

p

Tris

tel R

inse

Wip

es

√ √

WIP

ES

Tris

tel S

urfa

ce

Wip

es

√ √ √ √ √

UN

IVER

SAL

WIP

ES

√ √

Tris

tel P

re-C

lean

W

ipes

√ √ √ √ √

mik

rozi

d® Sens

itiv

e W

ipes

Wip

'Ani

ospr

emiu

m

√ √

√ √

Tris

tel S

pori

cida

l W

i pes

Tris

tel R

inse

W

ipes

√ √ √ √ √ √ √ √ √ √

Wip

Ani

os p

rem

ium

Cavi

Wip

es

√ √ √ √  √

Wip

es

UN

IVER

SAL

WIP

ES

√ √ √ √ √

Cavi

Wip

es 1

√  √ 

Wip

'Ani

os

prem

ium

Ult

raso

ndpr

obe

√ √ √ √ √

Tuff

le 5

ld

b

√  √  √

Ult

raso

und

prob

e cl

eani

ng w

ipes

√ √ √

ultr

asou

nd p

robe

cl

eani

ng w

ipes

√ √

Sani

Clo

th A

ctiv

e

√ √ √

Page 7: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

B-1 convvex probe

C5-1s/C5-2/CC6-2E/C6-2GC7-3E C11-33C1/33C5/36C2/635C2065C15SC5-1SC6-1SC8-265EC165EL665EC1

es

Probes

/C5-1E/C5-1C5-2s/C5-2E/C6-2

Gs/C6-2GE/C

E/ C11-3s/CC1s/3C1p C5s/3C5A/3C2P/6C2s

0EA/35C50E5EAV/65C15U/SC5-1E U U 0EA/65EC1

60EA 0ED

1U E

C6-2GU

C11-3U

3C5P

EA/35C50EB5EA

10EB/65EC1

B/35C50P

10EC

App

Disinfecta

pend

ants

dix BB Sp

TM/M

C

 

ray D

Oxi

virTM

/MC T

b

√ √ √ √ √ √ √ √ √ √ √ √ √

Disin

PI-S

PRA

Y-II

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

fecta

Surf

a'sa

fe

√ √ √ √ √ √ √ √ √ √ √ √ √

ants

TRA

NSE

PTIC

√ √ √ √ √ √ √ √ √ √ √

PRO

TEXTM

DIS

INFE

CTA

NT

√ √ √ √ √ √ √ √ √ √ √ √ √

DIS

INFE

CTA

NT

SPRA

Y

Tris

tel S

olo

√ √ √ √ √ √ √ √ √ √

IOD

OCL

EAN

√ √ √ √ √ √ √ √ √ √

Page 8: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

B-2 lineaar probes

ProbL7-3/L7-3sL9-3U/L9-3L10-3E/L10L11-3U L11-4/L11-L12-3/L12-L12-4/L12-L14-6/L14-L14-6N/L1L14-6WE/LL14-5W/L1L16-4HE/LLM14-6E/LL20-5U/L26LE7/6LE76LE5V/6LE7L4/7L4s/77LT4/7LT47L5/7L5P/7L6/7L6s 10L4/10L410L24EA 50L60EAV65L50HAV75L38EA/775L50EAV/

bes s/L7-3E 3E/L9-3s 0-3s

-4s -3E -4s -6s/L14-6P 4-6Ns/L14-

L14-6Ws/L114-5WU L16-4Hs/L16LM14-6s/LM20-5/L20-5s 7s/6LE7P E5Vs/6LE5V7L4A/7L4P

4s/7LT4P 7L5s

4s

V V 75L38EB/75/75LT38EA

-6NP/L14-64-6WU

6-4HU/L16-M16-4U

VP

5L53EA/75L

NE

-4Hs

L60EA/75L3

Disinfecta

38P

ants

 

Oxi

virTM

/MC T

b

√√ √√√√√√√ √ √ √√ √ √

PI-S

PRA

Y-II

√√

√√√√√√√√

√√√√√√√√

√√√√√

PISP

RAY

II

Surf

a'sa

fe

√√ √√√√√√√ √ √ √√ √ √

TRA

NSE

PTIC

√ √ √ √ √ √ √ √ √ √ √ √

PRO

TEXTM

DIS

INFE

CTA

NT

SPRA

Y

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

CTA

NT

SPRA

Y

Ti

tlS

l

√ √ √ √ √ √ √ √ √ √ √ √

Tris

tel S

olo

IOD

OCL

EAN

√ √ √ √ √ √ √ √ √ √ √

Page 9: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

Table

B-3 othe

B-4 4D p

r types of

robes

f probes

Pha

End

Pen

Bip

Probes

ased

do-cavity

ncil

plane

4CDD7-D6-D6-D8-D8-DE1DE1DE1

s

P4-2/P4-2P7-3/P7-3P10-4E/P1P12-4/P122P2/2P2s/SP5-1U/SPV11-3/V11V11-3HU/V10-4/10-6CV1/6CVCW2s/CW65EB10EACB10-4/C6LB7/6LB7

Probes

D4/4CD4A/-2/D7-2E/D-2/D6-2P/D-2NE -2U -4U 10-3E/DE1011-3U/DE1110-3WU

2s/P4-2E/P43s/P7-3E/P710-4s/P10-42-4s /2P2P P5-1s/SP5-11-3BE/V11-/ V11-3HE/V-4s/V10-4B/V1s/6CV1P

W5s/CW5 A B10-4P/CB17s/6LB7P

Disi

/4CD4s 7-2s

D6-2A/D6-2E

0-3U/DE10-1-3P/DE11-

Disinfe

4-2NE/P4-2N7-3P/P7-3U4U

1E 3B/V11-3W

V11-3Hs /V10-4Bs/V

10-4A/CB10

nfectants

E

3 -3s/DE11-3E

ectants

Ns

WE/ V11-3W

10-4BP/V10

0-4E

Oxi

virTM

/MC T

b √ √

E

 

s/V11-3E

0-4P

PI-S

PRA

Y-II

Surf

a'sa

fe

√ √√ √ √ √ √ √

Oxi

virTM

/MC T

b

PI-S

PRA

Y-II

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

TRA

NSE

PTIC

√ √ √

Surf

a'sa

fe

TRA

NSE

PTIC

√ √ √ √ √ √ √ √ √ √ √ √ √ √

PRO

TEXTM

DIS

INFE

CTA

NT

SPRA

Y

√ √

PRO

TEXTM

DIS

INF

ECTA

NT

SPRA

Y

√ √ √ √ √ √ √ √ √ √ √

Tris

tel S

olo

√ √

Tris

tel S

olo

√ √ √ √ √ √ √ √ √ √

Cavi

Cide

√ √

IOD

OCL

EAN

√ √ √

Page 10: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

C5-1sC5-2/C6-2C6-2GC7-3C11-33C1/3C5/6C2/635C265C1SC5-SC6-SC8-265EC65EL65EC

※Trop

C-1 conv

Probes

s/C5-1E/C5/C5-2s/C5-2E/C6-2 Gs/C6-2GE/E 3E/ C11-3s/3C1s/3C1p3C5s/3C5A6C2P/6C2s

20EA/35C505EAV/65C1

1U/SC5-1E 1U 2U

C10EA/65EC60EA

C10ED honSonex-

vex probe

-1U 2E

/C6-2GU

/C11-3U

A/3C5P

0EA/35C50E15EA

C10EB/65EC

HL (Used w

es

Disinfect

EB/35C50P

C10EC

with Tropho

tants

on EPR Ultra

A

CID

EX O

PA

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

asound Pro

Appe

Cide

x A

ctiv

ated

G

luta

rald

ehyd

e

√ √ √ √ √ √ √ √ √ √

be Disinfec

endi

Solu

tion

Met

riZy

me

√ √ √ √ √ √ √ √ √ √

ctor)

x C

Min

ncar

e® Co

ld

Ster

ilant

√ √ √ √ √ √ √ √ √ √

Solu

Ster

-Bac

Trop

honS

onex

-HL※

√ √ √ √ √√ √√ √√ √√ √√ √√ √ √ √ √√ √ √

 

10 

ution

Trop

honS

onex

HL※

Tria

cid-

N

√ √ √ √√ √√ √√ √√ √√ √√ √√ √ √ √ √√ √

n Disi

Revi

tal-O

xTM R

eser

t H

igh

Leve

l

nfec

Hig

h Le

vel

Dis

infe

ctan

t

ggig

asep

t® PAA

ctants

ggig

asep

tPA

A

conc

entr

ate

it®

FF(

)

√ √ √ √ √ √ √ √ √ √ √ √ √

s

giga

sept

®FF(

neu)

DES

COTO

Nex

tra

√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √√ √ √ √ √

DES

COTO

N e

xtra

AN

IOXY

DE

1000

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

√ √

SALV

AN

IOS

pH7

√ √ √ √ √ √ √ √ √ √ √ √

SALV

AN

IOS

pH10

√ √ √ √ √ √ √ √ √ √

CID

EX P

LUS

Milt

on

Page 11: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

P

L7-3/L7L9-3U/LL10-3E/L11-3U L11-4/LL12-3/LL12-4/LL14-6/LL14-6N/L14-6WL14-5WL16-4HLM14-6L20-5U/6LE7/6L6LE5V/67L4/7L47LT4/7L7L5/7L57L6/7L610L4/1010L24E50L60E65L50H75L38E/75L38P75L50E※Trop

C-2 linea

Probes

7-3s/L7-3E L9-3E/L9-3s/L10-3s

L11-4s L12-3E L12-4s L14-6s/L14-/L14-6Ns/L

WE/L14-6WsW/L14-5WU

E/L16-4Hs/6E/LM14-6s/L20-5/L20LE7s/6LE7P6LE5Vs/6LE4s/7L4A/7LLT4s/7LT4P5P/7L5s 6s 0L4s A

EAV HAV

A/75L38EBP AV/75LT38honSonex-

ar probes

Disinf

s

-6P L14-6NP/L14s/L14-6WU

/L16-4HU/L/LM16-4U -5s

P E5VP L4P P

B/75L53EA/7

8EA HL (Used w

fectants

4-6NE

16-4Hs

75L60EA

with Tropho

CID

EX O

PA

√ √ √ √ √ √ √ √ √ √

√ √ √ √ √ √ √ √ √ √ √ √ √

√ on EPR Ultra

Cide

x A

ctiv

ated

G

luta

rald

ehyd

e So

luti

on

√ √ √ √√ √ √√ √√ √√ √√ √√ √√ √ √√ √√ √

√ √asound Pro

Met

riZy

me

Min

ncar

e® Co

ld S

teri

lant

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

√ √ be Disinfec

Ster

-Bac

Trop

honS

onex

HL※

√ √√ √ √ √ √ √ √ √ √ √ √√ √√ √√ √√ √√ √√ √ √ √√ √√ √

√ √ctor)

Trop

honS

onex

-HL※

Tria

cid-

N

√ √ √ √ √ √ √ √

√ √

√ √ √ √ √ √ √ √ √ √ √ √

√ √ √ √ √ √

√ √

Revi

tal-O

xTM R

eser

t Hig

h Le

vel D

isin

fect

ant

 

11 

ggig

asep

t® PAA

con

cent

rate

AN

IOXY

DE

1000

√ √√ √ √ √√ √√ √√ √ √√ √√ √ √ √ √ √ √ √√ √ √ √ √ √

AN

IOXY

DE

1000

DES

COTO

N e

xtra

√ √ √ √ √ √ √ √ √ √ √ √

gi

gase

pt®F

F(ne

u)

SALV

AN

IOS

pH7

√ √√ √ √ √ √√ √√ √ √√ √√ √ √ √ √ √ √ √√ √ √ √ √

p

SALV

AN

IOS

pH10

√ √ √ √ √ √

√ √ √ √ √ √

Prol

ysti

ca 2

X Co

ncen

trat

e En

zym

atic

√ √

Liqu

inox

Cide

zym

e

√ √

Nu-

Cide

x

√ √

Alk

azym

e

Klne

zym

e

√ √

Ster

anio

s

Page 12: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Table

Table

4CD7D6D6D8D8DEDEDE

※Trop

C-3 othe

Pr

Phased

Endo-ca

Pencil

Biplane

C-4 4D p

ProbesCD4/4CD4A7-2/D7-2E/D6-2/D6-2P/D6-2NE 8-2U 8-4U E10-3E/DE1E11-3U/DE1E10-3WU honSonex-

r types of

obes

P4-2P7-3P10P122P2SP5

vity

V11V11V106CVCW265ECB16LB

robes

s A/4CD4s D7-2s D6-2A/D6-2

0-3U/DE1011-3P/DE11

HL (Used w

f probes

2/P4-2s/P4-3/P7-3s/P7-

0-4E/P10-4s2-4/P12-4s 2/2P2s/2P2P

-1U/SP5-1s-3/V11-3BE-3HU/ V11-

0-4/10-4s/VV1/6CV1s/62s/CW5s/C

EB10EA 0-4/CB10-4

B7/6LB7s/6L

Disin

2E

0-3 1-3s/DE11-3

with Tropho

Dis

-2E/P4-2NE-3E/P7-3P/P/P10-4U

P s/SP5-1E E/V11-3B/V-3HE/V11-310-4B/V10-CV1P W5

4P/CB10-4ALB7P

nfectants

3E

on EPR Ultra

sinfectants

E/P4-2Ns P7-3U

11-3WE/ V13Hs -4Bs/V10-4B

A/CB10-4E

CID

EX O

PA

√ √√√√√√√√

asound Pro

s

11-3Ws/V11

BP/V10-4P

Met

riZy

me

Min

ncar

e® Cold

S

il

√ √ √ √√ √ √√ √ √ √ √ √ √√

be Disinfec

CID

EX O

PA

√ √ √ √ √

1-3E √ √ √ √ √ √ √ √

Ster

ilant

Ster

-Bac

Trop

honS

onex

√ √ √ √ √

ctor)

Met

riZy

me

Min

ncar

Cold

√ √ √ √ √ √ √ √

Trop

honS

onex

-HL※

Tria

cid-

N

√ √√ √ √

Cold

St

erila

nt

Ster

-Bac

√ √ √ √√ √√ √ √ √√ √ √√ √√ √√ √√ √

Revi

tal-O

xTM

Rese

rt H

igh

Leve

l D

ii

ft

t√ √

 

12 

Ster

Bac

Trop

honS

on

ex-H

L※

√ √

√ √ √ √ √ √

√ √

√ √ √ √ √ √ √ √ √

Dis

infe

ctan

t

ggig

asep

t® PAA

co

ncen

trat

e

Tria

cid-

N

Revi

tal-O

xTM

√ √ √ √ √ √ √ √ √ √ √ √

conc

entr

ate

DES

COTO

N

extr

a

giga

sept

® FF

Rese

rt H

igh

Leve

l D

isin

fect

ant

√ √

giga

sept

FF

(neu

)

Cide

x

√√  √ √√ √

ggig

asep

t® PA

A

conc

entr

ate

√ √ √ √ √ √ √

Cide

x Pl

us

Gig

asep

t AF

√  √ √  √

DES

COTO

N

extr

a

AN

IOXY

DE

√ √ √ √ √ √ √ √√ √√ √√ √

Osv

an

Neo

jodi

n

√  √

1000

giga

sept

®FF

(neu

)

√ √

√ √

√ √ √ √ √ √ √ √ √ √ √

eojo

d

Milt

on

hibi

tane

√  √  √

SALV

AN

IOS

pH7

√ √ √ √ √ √ √ √

Ster

ihyd

e

SALV

AN

IOS

H

√ √

√  √  √

SALV

AN

IOS

pH10

Cide

x

√ √ √ √ √ √ √ √ √ √ √

pH7

AN

IOXY

DE

1000

√ √ √ √ √ √

Cide

x A

ctiv

ated

G

luta

rald

ehy

de S

olut

ion

√ √ √

Cide

x A

ctiv

ated

G

luta

rald

ehyd

e So

luti

on

√ √ √

Cide

zym

e

Page 13: recautions 1 Inspection BBefore and After Useres.mindray.com/AntisepticDocuments/2017-05-24/8c978920-3356-4729... · DRAY Custo he Tran, such as pe to the pat t your MIND gulation.

Appdis

NOTE: pUltrasounew ediNOTE: Reach disRelease

CaviWipdiisobut

CaviWip(2-butox

CaviCide(2-butoxchloride

CLEANISammoniMinncarmikrozidNu-Cide

P

4CD4/4D7-2/DD6-2/DD6-2NED8-2U D8-4U DE10-3DE10-3DE11-3

pendsinfe

please selectund System.tions.

Refer to locasinfectant, p

date:May

pes: isopropaylphenoxyet

pes 1: isopropxyethanol), d

e: isopropxyethanol), , water

SEPT® WIPESium compoure® Cold Sterd®AF Wipes

ex: 0.35%per

Probes

4CD4A/4CD7-2E/D7-2s6-2P/D6-2A

E

E/DE10-3UWU U/DE11-3P

dix Dectan

t the proper . The conten

al regulatioplease refer t

17

anol, ethylenthoxyethyl di

panol, ethanidecyldimeth

panol, ethdiisobutylph

S: 0.25g didnds,benzy

rilant: 22% HJumbo: 25%acetic acid

Disinfect

D4s s A/D6-2E

/DE10-3

P/DE11-3s/D

D Gents (4

disinfectantnt of this doc

ns for the uto the manu

e glycol monimethyl benz

ol, ethylene hylammoniu

anol, ethyhenoxyethox

decyldimethyl-C12-16-alky

Hydrogen Per% ethanol; 35%

tants

DE11-3E

els an4D pr

t for the procument shal

use of each ufacturer’s in

nobutyl etherzyl ammoniu

glycol monom chloride, w

ylene glycxyethyl dime

ylammoniumyldimethyl-,roxide, 4.5% % propan-1-

Gel

Aqu

ason

ics

100

Sl

√  √√  √√  √√  √

nd poobe

obe of the Dill prevail in c

disinfectannstructions

r (2-butoxyetm chloride, w

obutyl ether water

col monobethyl benzy

mchloride 0.5chlorides

Peroxyaceticol

s

Sono

gel

Scan

Rely

+On

√  √ √  √ √  √ √  √ 

owdeonly

iagnostic case of othe

t. For use o

thanol), water

butyl ethel ammonium

5g quaternar

c Acid

Powder

Rely

+On

Pera

Safe

Pera

Safe

√ √  √ 

er y)

er

of

er m

ry

Ster-BaUNIVERpolyhex

PI-SPRAdimethychloride

MetriZyTristel RCidex OOxivirTM

Tristel STristel STristel PANIOXYWip'Anpolyhex

Cidex ATRANSEgigasepdimethosurfacta

gigasepperoxid

Sani-Clo[(ethylphammoniMetriSpPropyleProprietProtex di-C8-10compouPropriet

ac/mikrozid®

RSAL WIPES:xamethylene

AY-II: Octyl yl ammoniue, Benzalkoni

yme/CidezymRinse Wipes

OPA: 0.55% OM/MC Tb: 0.5%Surface WipSolo: polyhexPre-Clean WYDE 1000: 3%ios premium

xamethylene

Activated GluEPTIC: isopropt®FF(neu): oxytetrahydrants; anti-cor

pt®PAA cone: acetic acid

oth AF3: Qhenyl) methyl]um chloridesponge: Watne glycol,Ntary, Proteina

Ultra W0-alkyldimethunds, benzytary Ingredie

Activ®Sensitive W: didecyldime

e biguanide h

decyl dimeum chlorideium chloride

me/Alkazyms: deionized wOrtho-phthlad% hydrogen ppes/Tristel Tr

xamethylbigWipes: enzym

% Hydrogen m: didecyldime biguanide h

utaraldehydopyl alcohol,

0.11g rofuran; < rosion comp

ncentrate: d; potassium

Quaternary a] dimethyl, ch

ter and nonNonionic Surase subtilisin

Wipes: Quathyl, chloriyl-C12-16-alkents

 

13 

ve IngWipes: Quater

ethylammonhydrochloride

ethyl ammoe, Didecyl

me/Klnezymewater dehyde

peroxide rio Wipes Syguanide

atic detergenPeroxide

methylammohydrochloride

de Solution: chlorhexidin

succin5% anionic

pounds; fragra

peracetic hydroxide: c

mmonium chloridesk, Be

n-hazardous rfactants Pro,Octamethternary amdes , Qu

kyldimethyl,

gredirnary Ammon

nium chloridee 0.96mg/g

onium chloridimethyl

e: Proteinase

ystem: chlorin

nt

onium chloride 0.96mg/g

glutaraldehyne gluconatendialdehyde;c surfactant;ance

acid (5%); corrosion inh

compounds, enzyl-C12-18-a

ingredients oprietary,Frhylcyclotetrasmmonium cuaternary

chlorides ,

ents niums e 1.4mg/g,

de, Dioctyl ammonium

e substilisin

ne dioxide

de 1.4mg/g,

yde e

0.3g ; non-ionic

hydrogen ibitor

C12-18-alkyl alkyldimethyl

Mixture,agrance Oil

siloxane compounds ammonium

Water ,

of th

ultrasounDI Water: wBleach 5.2Sporox II: PeraSafe: Sani ClothCidex PlusSonogel: cOsvan: AmMilton:sodMinncare®

Liquinox:Steranios:ProtexTM DammoniumammoniumTriacid-N: non-ionic d

Surfa'safebiguanide

Revital-Oxperoxide

DI Water: wBleach 5.2Ethanol 75Sporox II: DESCOTOIODOCLEASALVANIOpropionate

Sani-Clothethylbenzy

SONOTM Udimethyl abenzyl am

he Disd probe cleawater Et

25% (10% SoHydrogen Pe

Disodium cah Acive: Dides: glutaraldehcarbomer, po

mmonia benzdium hypoch® Cold Sterila

Sodium sul: 2% glutarald

Disinfectant m chloride; m chloride; d

N-Dodecylpdetergent

e: didecyldimhydrochlorid

xTM Resert

water 25% (10% So5%: Alcohol Hydrogen PeN extra: 12%

AN: sodium tOS pH7/SAe, excipients

h® Plus: n-yl ammonium

ULTRASOUNDammonium cmonium chlo

sinfecaning wipesthanol 75%: olution): Soderoxide

arbonate, citrecyldimethyl hyde Cidolyacrylat zalkonium Nehlorite Hiant: 22% Hydlfonate,Tripodehyde Spray/Protedioctyl dimimethyl benzropan-1,3-di

methylammode 0.96mg/g

High Level

olution): Sod

eroxide % glutaral thiosulfate an

ALVANIOS

-Alkyl dimem chloride

D WIPES: occhloride; didoride

ctant: Poly-prenylAlcohol

dium Hypoch

ric acid, sodiuammonium

dex: alkaline Sterihyde: G

eojodin: povibitane: hlordrogen Peroxtassium

exTM Disinfeethyl ammozyl ammoniuamin;propa

nium chlori

Disinfecta

dium Hypoch

nd excipientspH10: Gua

ethyl benzy

tyl decyl dimdecyl dimeth

ts l acetate, pro

hlorite

um carbonatchloride 0.45glutaraldehy

Glutaraldehyvidone-iodinerhexidine xide, 4.5% Pe

ectant Wipesonium chlorum chloridean-2-ol;isotri

ide 1.4mg/g

ant/Trophon

hlorite

s anidinium

yl ammoniu

methyl ammohyl ammoniu

opylene glyco

e 50%w/w yde de e

eroxyacetic A

s: octyl decylide; didecyl

decanol, eth

g, polyhexam

Sonex-HL:

acetate, am

um chloride

onium chloridum chloride;

ol

Acid

l dimethyl dimethyl

hoxylated;

methylene

hydrogen

mmonium

e n-Alkyl

de; dioctyl ; dimethyl


Recommended