+ All Categories
Home > Documents > Received - eco.tpchd.org

Received - eco.tpchd.org

Date post: 09-Jan-2022
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
3
880 872 874 876 878 882 W W FOR HEALTH DEPARTMENT USE P.O. Box 740, Puyallup, Washington 98371 (253) 848-6608 Fax: (253) 840-4140 www.lseinc.com SURVEYING ENGINEERING GEOLOGY SEPTIC DESIGN GPS GIS MAPPING 04/30/2021 SHEET C:\Users\eevers\AppData\Local\Temp\AcPublish_7968\13278-S.dwg LAST EDITED: 04/30/21 12:05PM BY: EEvers 04/30/2021 P.O. Box 740, Puyallup, Washington 98371 (253) 848-6608 Fax: (253) 840-4140 www.lseinc.com SURVEYING ENGINEERING GEOLOGY SEPTIC DESIGN GPS GIS MAPPING © LEROY SURVEYORS & ENGINEERS 04/30/21 CLIENT: PARCEL NO. SUBDIVISION: DATE: LOT NO. SCALE: JOB NO. DESIGNER: DRAWN: CERT. NO. INSTALLER: PHONE NUMBER: ADDRESS: ON-SITE WASTEWATER DESIGN: 25716 99TH AVE E CHUCK ANDERSON 281-528-6201 31 QUINCE TREE PL CONROE, TX 77385 3161000280 BILL CREVELING 2353 28 ERE COLUMBIA CREST VIEW 13278 SEE DWG 1 3 04/30/2021 0 GRAPHIC SCALE 1 INCH = FEET 20 10 20 20 LSE NW NE SE SW EXPIRATION DATE: 12/10/22 VICINITY MAP SCALE: 1" = 1,000 257TH ST CT E 161 99TH AVE E SITE BEFORE ANY CONSTRUCTION CONTACT: CALL BEFORE YOU DIG @ 1-800-424-5555 THIS IS NOT A SURVEY SITE FEATURES, TOPOGRAPHY, ELEVATIONS AND BENCHMARKS ARE BASED ON ASSUMED DATAM PROVIDED BY THE OWNER, PIERCE COUNTY RECORDS AND THE PUGET SOUND LiDAR CONSORTIUM. THIS DATUM IS INTENDED FOR THE REVIEW AND CONSTRUCTION OF THE PROPOSED SEPTIC DESIGN ONLY. LSE INC. RECOMMENDS THAT A LICENSED PROFESSIONAL LAND SURVEYOR ALWAYS BE USED TO SET CORNERS, ESTABLISH LOT LINES, DETERMINE ELEVATIONS AND TOPOGRAPHY AND/OR PROVIDE A LEGAL SITE PLAN. SL 2 SL 1 SL 3 SL 4 SL A SOILS LOGGED 4-21-21 BY: BILL CREVELING SL-1 0-49" BRN LMY FN SD 49-70" GRAY FRAG. W.T. SL-2 0-36" BRN LMY FN SD, ROOTED >36" 36-70" GRAV LOMY MD SD SL-3 0-34" BRN LMY FN SD 34-44" GRAY FRAG. W.T. SL-4 0-44" BRN LMY FN SD 49-70" GRAY SDY LM SL-A 0-12" BRN LM 12-50" BRN GRAV LMY FN SD 151.51' 152.47' 106.00' 106.00' 99TH AVE E SEPTIC TANK PUMP CHAMBER 5' MIN C/O 5' MIN PROPOSED PRIMARY DRAINFIELD, 267 LF, 800 SF VALVE MANIFOLD PORTS TYP TL 38' 38' 38' 38' 38' 38' 39' 27' 40' 40' 40' 40' 40' 40' OLD PHONE LINE PROPOSED 4 BDRM SFR BUILDING ENVELOPE INSTALLATION ELEVATIONS: MIN. STUB OUT: I.E. = SEPTIC INLET: I.E. = SEPTIC OUTLET: I.E. = PUMP INLET: I.E. = PUMP DISCHARGE: I.E. = LATERAL ELEVATION = _____________ _____________ _____________ _____________ _____________ _____________ 872.00 871.75 871.50 871.25 866.25 881.00 RESERVE DRAINFIELD, 267 LF, 800 SF PHONE LINE NOTE: THE PHONE LINE HIT DURING SOIL OBSERVATION IS TO BE LOCATED AND THE UTILITY PROVIDER WILL BE CONTACTED TO ENSURE THE LINE IS NO LONGER IN USE. PROPOSED DRIVEWAY 10' MIN 5' MIN Received 8/7/2021
Transcript
Page 1: Received - eco.tpchd.org

880

872

874

876

878

882

W W

FOR HEALTH DEPARTMENT USE

P.O. Box 740, Puyallup, Washington 98371(253) 848-6608 Fax: (253) 840-4140

www.lseinc.com

SURVEYINGENGINEERING

GEOLOGYSEPTIC DESIGN

GPSGIS MAPPING

04/30

/2021

SHEET

C:\U

sers

\eev

ers\

AppD

ata\

Loca

l\Tem

p\Ac

Publ

ish_

7968

\132

78-S

.dw

g L

AST

EDIT

ED: 0

4/30

/21

12:0

5PM

BY

: EEv

ers

04/30

/2021

P.O. Box 740, Puyallup, Washington 98371(253) 848-6608 Fax: (253) 840-4140

www.lseinc.com

SURVEYINGENGINEERING

GEOLOGYSEPTIC DESIGN

GPSGIS MAPPING

© LEROY SURVEYORS & ENGINEERS 04/30/21

CLIENT:

PARCEL NO. SUBDIVISION:

DATE:

LOT NO.

SCALE:

JOB NO.

DESIGNER:

DRAWN:

CERT. NO.

INSTALLER:

PHONE NUMBER:

ADDRESS:

ON-SITE WASTEWATER DESIGN: 25716 99TH AVE E

CHUCK ANDERSON

281-528-6201

31 QUINCE TREE PL

CONROE, TX 77385

3161000280

BILL CREVELING

2353

28

ERE

COLUMBIA CREST VIEW

13278

SEE DWG

1

304/30/2021

0GRAPHIC SCALE

1 INCH = FEET

20 10 20

20

LSE

NW NESESW

EXPIRATION DATE: 12/10/22

VICINITY MAPSCALE: 1" = 1,000

257TH ST CT E

161

99TH

AVE

E

SITE

BEFORE ANY CONSTRUCTION CONTACT:CALL BEFORE YOU DIG @ 1-800-424-5555

THIS IS NOT A SURVEYSITE FEATURES, TOPOGRAPHY, ELEVATIONS AND BENCHMARKS ARE BASED ON ASSUMED DATAM PROVIDED BY THEOWNER, PIERCE COUNTY RECORDS AND THE PUGET SOUND LiDAR CONSORTIUM. THIS DATUM IS INTENDED FOR THEREVIEW AND CONSTRUCTION OF THE PROPOSED SEPTIC DESIGN ONLY. LSE INC. RECOMMENDS THAT A LICENSEDPROFESSIONAL LAND SURVEYOR ALWAYS BE USED TO SET CORNERS, ESTABLISH LOT LINES, DETERMINE ELEVATIONS ANDTOPOGRAPHY AND/OR PROVIDE A LEGAL SITE PLAN.

SL 2SL 1

SL 3

SL 4

SL A

SOILS LOGGED 4-21-21BY: BILL CREVELING

SL-1 0-49" BRN LMY FN SD49-70" GRAY FRAG. W.T.

SL-2 0-36" BRN LMY FN SD, ROOTED >36"36-70" GRAV LOMY MD SD

SL-3 0-34" BRN LMY FN SD34-44" GRAY FRAG. W.T.

SL-4 0-44" BRN LMY FN SD49-70" GRAY SDY LM

SL-A 0-12" BRN LM12-50" BRN GRAV LMY FN SD

151.51'

152.47'

106.

00'

106.

00'

99TH

AVE

E

SEPTIC TANK

PUMP CHAMBER

5' MIN

C/O

5' MIN

PROPOSED PRIMARYDRAINFIELD, 267 LF, 800 SF

VALVE MANIFOLD

PORTS TYP

TL

38'

38'

38'

38'

38'

38'

39'

27'

40'

40'

40'

40'

40'

40'

OLD PHONE LINE

PROPOSED 4 BDRM SFRBUILDING ENVELOPE

INSTALLATION ELEVATIONS:MIN. STUB OUT: I.E. =SEPTIC INLET: I.E. =SEPTIC OUTLET: I.E. =PUMP INLET: I.E. =PUMP DISCHARGE: I.E. =LATERAL ELEVATION =

______________________________________________________________________________

872.00871.75871.50871.25866.25881.00

RESERVE DRAINFIELD,267 LF, 800 SF

PHONE LINE NOTE:THE PHONE LINE HIT DURING SOILOBSERVATION IS TO BE LOCATED AND THEUTILITY PROVIDER WILL BE CONTACTED TOENSURE THE LINE IS NO LONGER IN USE.

PROPOSEDDRIVEWAY

10' MIN

5' MIN

Received8/7/2021

Page 2: Received - eco.tpchd.org

ELEVATION-PUMP DISCHARGE TO LATERAL I.E.TRANSPORTMANIFOLDLATERALRESIDUAL HEADTOTAL T.D.H.

==

L.F.L.F.L.F.

=PVC PIPE==

=

FTFTFTFTFTFT

PVC PIPEPVC PIPE

LOSS15.04.11.17.92.030.1

14540

39

2"2"

1.25"

SCH40SCH40SCH40

MIN. REQUIRED ABSORPTION AREA ____ SQ FTAPPLICATION RATE _____ GAL/SQ FT/DAY

NUMBER OF BEDROOMS ____GALLONS PER DAY ______

SPECIFICATIONS

TOTAL ORIFICES _______

ORIFICE SPACING _______

4480

8000.6

48"

67TOTAL FLOW _______ GPM39.5

ORIFICE DIAMETER _______3/16"ORIFICE FLOW _______ GPM0.59

FOR HEALTH DEPARTMENT USE

MIN. REQUIRED DRAINFIELD TRENCH ____ LF267

APPROVED OUTLETFILTER WITH HANDLE6" TO GRADE

CAST-IN RISERADAPTERS (2 TOT)

6" PVC COUPLER

BAFFLE INSPECTION PORT

SCALE:SEPTIC TANK DETAIL (1,000 GAL. MIN.)

SEDIMENTS

REDUNDANT OFF LEVEL

TIMER OFF LEVELTIMER ON LEVEL

HIGH WATER ALARM LEVEL

24" DIAMETER ACCESS RISERSECURED LID WITH GAS TIGHT SEAL

18"

EMERGENCY STORAGE(75% DAILY FLOW)

360 GALLONS

PUMP SUBMERGENCE ZONE(400 GALLONS)

ENCLOSED PUMP SEDIMENT SHROUD

SUBMERSIBLECENTRIFUGALPUMP

INDEPENDENTFLOAT STEM FORFLOAT MOUNTING

ANTI-SIPHONVALVE(IF APPLICABLE)

THREADEDUNION

FINISH GRADESERVICE VALVETO DRAINFIELD

CHECK VALVE

BLOCK

SCALE:PUMP CHAMBER DETAIL (1,250 GAL.)

WORKING VOLUME 480 GALLONS

NOTE: SET PUMP INLET IE. 4 INCHES LOWER THAN FIRST TANK OUTLET IE.TO INSURE 1300 GAL TOTAL FLOOD CAPACITY IN PUMP TANK

N.T.S.

N.T.S.

© LEROY SURVEYORS & ENGINEERS 04/30/21

04/30

/2021

SHEET

C:\U

sers

\eev

ers\

AppD

ata\

Loca

l\Tem

p\Ac

Publ

ish_

7968

\132

78-S

.dw

g L

AST

EDIT

ED: 0

4/30

/21

12:0

5PM

BY

: EEv

ers

© LEROY SURVEYORS & ENGINEERS 04/30/21

6" MIN

FINISHED GRADEFINISHED GRADE

P.O. Box 740, Puyallup, Washington 98371(253) 848-6608 Fax: (253) 840-4140

www.lseinc.com

SURVEYINGENGINEERING

GEOLOGYSEPTIC DESIGN

GPSGIS MAPPINGP.O. Box 740, Puyallup, Washington 98371

(253) 848-6608 Fax: (253) 840-4140www.lseinc.com

SURVEYINGENGINEERING

GEOLOGYSEPTIC DESIGN

GPSGIS MAPPING

CLIENT:

PARCEL NO. SUBDIVISION:

DATE:

LOT NO.

SCALE:

JOB NO.

DESIGNER:

DRAWN:

CERT. NO.

INSTALLER:

PHONE NUMBER:

ADDRESS:

04/30/2021

EXPIRATION DATE: 12/10/22

BEFORE ANY CONSTRUCTION CONTACT:CALL BEFORE YOU DIG @ 1-800-424-5555

PUMP MUST BE CAPABLE TO DELIVER _____ G.P.M. AGAINST ______ FT OF HEAD.FOR PUMP SPECIFICATIONS SEE THIS SHEET OR USE EQUIVALENT. CONTROLSARE TO BE SET TO DOSE ___ CYCLES PER DAY AT _____ GAL/CYCLE. USE ANAPPROVED, UL LISTED, TIMED DOSING CONTROL PANEL WITH BOTH AN ELAPSEDTIME METER AND CYCLE COUNTER.PUMP OFF TIME: ____ HOURS.

PUMP40 30.1

6 80

4

10 20 30 40 50 60 7000

10

20

30

40

50

60

70

U.S. GALLONS PER MIN.

TOTA

L H

EAD

IN F

EET

SCALE:

SHEF50 - HYDROMATIC(1/2 H.P. - 3,450 RPM)

N.T.S.

ON-SITE WASTEWATER DESIGN: 25716 99TH AVE E

CHUCK ANDERSON

281-528-6201

31 QUINCE TREE PL

CONROE, TX 77385

3161000280

BILL CREVELING

2353

28

ERE

COLUMBIA CREST VIEW

13278

SEE DWG

2

3

Received8/7/2021

Page 3: Received - eco.tpchd.org

DRAIN ROCK

1/2" REBAR ANCHOR

6" PVC SLIP CAP

UPSWEPT PVC LATERAL

6" PERFORATED PVCGEOTEXTILE

MINERAL SOIL

FINISH GRADE

BUILDER / HOMEOWNER NOTES1. BUILDER SHALL PROVIDE SITE PLAN TO THE DESIGNER PRIOR TO SUBMITTAL FOR BUILDING PERMIT.2. DRAINFIELDS THAT ARE TO BE INSTALLED IN THE TOP 12" OF NATIVE SOIL WILL REQUIRE A LICENSED INSTALLER TO CLEAR THE DRAINFIELD AREA.3. IF A STORM SYSTEM IS REQUIRED TO BE INSTALLED ON SITE, THIS LOCATION WILL NEED TO BE NOTED ON THE SITE PLAN GIVEN TO THE DESIGNER.4. BUILDER SHALL GIVE A COPY OF THE DESIGN TO THE POTENTIAL LANDSCAPER AND THE NEW HOMEOWNER.5. TOPOGRAPHY, BENCHMARK AND STUB-OUT ELEVATIONS BASED ON ASSUMED DATA SHOULD NOT BE USED FOR ANY PURPOSE OTHER THAN DESIGN OF

THE DRAINFIELD SYSTEM.6. ANY DEVIATION OR ALTERATION OF THE HOUSE PLAN OR LOCATION MAY REQUIRE REVISION OF THE SEPTIC DESIGN AND MUST BE APPROVED BY THE

DESIGNER PRIOR TO MODIFICATION. PLEASE CONTACT LEROY SURVEYORS & ENGINEERS. THIS PLAN IS COPYRIGHTED.7. NO EXCAVATION. ALTERATION, REMOVAL OF SOIL OR ENCROACHMENT OF IMPROVEMENTS WITHIN THE PRIMARY AND RESERVE DRAINFIELD AREAS IS

ALLOWED.8. DIVERT ALL DOWN SPOUTS OR ROOF DRAINAGE WATER AWAY FROM SEPTIC SYSTEM COMPONENTS.9. GARBAGE DISPOSAL UNITS ARE NOT ALLOWED ON THIS SEPTIC DESIGN. THIS SYSTEM IS DESIGNED TO TREAT RESIDENTIAL STRENGTH SEWAGE.

EFFLUENT WASTE STRENGTH SHOULD NOT EXCEED 125 MG/L CBOD5; 80 MG/L TSS; OR 20 MG/L O&G.10. ON-SITE WASTEWATER SYSTEMS REQUIRE ONGOING MONITORING AND MAINTENANCE TO ASSURE PROPER LONG-TERM FUNCTION. PLEASE REFER TO

CHAPTER 2 ON-SITE SEWAGE - ENVIRONMENTAL HEALTH CODE - B.O.H. RESOLUTION NO. 2010-4222 FOR OPERATION AND MAINTENANCE REQUIREMENTS.11. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE PIERCE COUNTY HEALTH DEPARTMENT.

INSTALLER NOTES1. SHOULD SITE CONDITIONS DIFFER FROM DESIGN, OR IF ANY OTHER PROBLEMS ARE OBSERVED; PLEASE CONTACT DESIGNER PRIOR TO PROCEEDING WITH

INSTALLATION.2. THE PUMP MUST HAVE A UL LISTING AND IDENTIFICATION NUMBER.3. ALL EQUIPMENT MUST BE INSTALLED FOLLOWING MANUFACTURES INSTRUCTIONS.4. IF SEWER LINES AND WATER LINES CROSS, THE WATER LINE MUST BE AT LEAST 18" ABOVE THE SEWER LINE AND SLEEVED WITHIN A RIGID LEAK PROOF

PIPE FOR A MINIMUM OF 10'-0" HORIZONTALLY FROM THE CENTER OF THE WATER LINE. IF THE WATERLINE IS BETWEEN 5'-0" AND 10'-0" FROM THE SEWERLINE, THE WATER LINE MUST BE ENCASED IN PIPE.

5. INSTALLER MUST CONTACT THE DESIGNER FOR SYSTEM CONSTRUCTION INSPECTIONS. SYSTEM MUST BE UNCOVERED AND ACCESSIBLE.6. INSTALLER TO PROVIDE A COMPLETED "BACKFILL VERIFICATION AND SYSTEM SPECIFICATIONS" FORM TO DESIGNER UPON COMPLETION OF

CONSTRUCTION AND TESTING. PROPERTY OWNER IS RESPONSIBLE FOR ANY ADDITIONAL REQUIRED MAINTENANCE CONTRACTS.

TRANSPORT LINE

TEE

PLAN VIEW

ACCESS UTILITY BOXTO FINISH GRADE

PVC GATEVALVE

NUMBER OF LATERAL SUPPLYLINES MAY VARY - SEE PLAN

SCALE:VALVE CONTROL BOX AND LATERAL DETAIL (TYP)

SCALE:ACCESS PORT DETAIL

SLIP CAP

FOR HEALTH DEPARTMENT USE

SCALE:TRENCH DETAIL

CARSON BOX

36"

ORIGINAL GRADE

BRN LMYFN SD

2"

12-24"

NOTE: MAINTAIN AT LEAST 2.0' VERTICAL SEPARATION ABOVERESTRICTIVE LAYER OR GROUNDWATER

PVC PERFORATED PIPESEE LOSS CALCS FOR SIZE

GRAYFRAG WT

6-24" MINERAL SOIL -PER TPCHD REQ

3/4" - 2 1/2" WASHEDDRAIN ROCK

GEOTEXTILE

6"

49"

70"

00"

N.T.S.

N.T.S.

N.T.S.

SHEET

C:\U

sers

\eev

ers\

AppD

ata\

Loca

l\Tem

p\Ac

Publ

ish_

7968

\132

78-S

.dw

g L

AST

EDIT

ED: 0

4/30

/21

12:0

5PM

BY

: EEv

ers

© LEROY SURVEYORS & ENGINEERS 04/30/21

04/30

/2021

P.O. Box 740, Puyallup, Washington 98371(253) 848-6608 Fax: (253) 840-4140

www.lseinc.com

SURVEYINGENGINEERING

GEOLOGYSEPTIC DESIGN

GPSGIS MAPPINGP.O. Box 740, Puyallup, Washington 98371

(253) 848-6608 Fax: (253) 840-4140www.lseinc.com

SURVEYINGENGINEERING

GEOLOGYSEPTIC DESIGN

GPSGIS MAPPING

CLIENT:

PARCEL NO. SUBDIVISION:

DATE:

LOT NO.

SCALE:

JOB NO.

DESIGNER:

DRAWN:

CERT. NO.

INSTALLER:

PHONE NUMBER:

ADDRESS:

04/30/2021

FINISH GRADE

SLIP CAP

SECTION VIEW

NOTE: INSTALL MANIFOLD A MIN 3" HIGHERTHAN HIGHEST LATERAL.

PVC GATEVALVE

PVC LATERAL

TYPICAL

FOR ORIFICE SIZINGSEE PRESSURE CALCS

ORIFICE ORIENTATION _____________6:00 O'CLOCK

EXPIRATION DATE: 12/10/22

BEFORE ANY CONSTRUCTION CONTACT:CALL BEFORE YOU DIG @ 1-800-424-5555

ON-SITE WASTEWATER DESIGN: 25716 99TH AVE E

CHUCK ANDERSON

281-528-6201

31 QUINCE TREE PL

CONROE, TX 77385

3161000280

BILL CREVELING

2353

28

ERE

COLUMBIA CREST VIEW

13278

SEE DWG

3

3

Received8/7/2021


Recommended