Punctual
Passive
Active thermodynamics
Active hidronic
With dehumidification
Commercial
Ductworks
HRVHeat
RecoveryVentilation
INNOVA s.r.l. Via I Maggio 8, 38089 Storo - TN, ITALY
T. +39 0465 670104E: [email protected]
www.innovaenergie.com
Edizione | Edition 2019
AMBIENT AIR INTAKE
BUTLERThe web is at service of your homeThe BUTLER web server is a new INNOVA system to manage an entire air conditioning system from a local and remote network. BUTLER is powerful, simple and economic at the same time; It consists of a Web Server card integrated in a micro computer, which allows to connect the heat pumps, ventilation systems and fancoils, equipped with electronic controls with Modbus port, to a normal wired or wireless LAN.
There fore is possible to con gure an entire system or individual fancoils networks to control them from a smart phone, tablet or computer via local or remote connection; it is also possible to set for each one: a weekly calendar with time slots, create zones, operating scenarios such as house, school, hotel, and etc. All the functions are executable without installation of an additional software in directing to an IP address or via an free of charge APP.
HRA DOMO HRA-I DOMO
08 14 20 H 30 H
80 140 200 300
0,96 1,64 2,69 3,57
0,62 1,02 1,44 2,16
10,7 / 4,1 9,6 / 3,9 11,7 / 4,0 9,9 / 3,9
38 41 39 43
TECHNICAL DATA u.m.
Renewal air flow rate m3/h
Heating power * kW
Cooling power ** kW
COP / EER
Sound pressure at 3 m dB(A)
ACCESSORIES HRA DOMO & HRA-I DOMO
AUTOMATIC DIGITAL GRAPHIC REMOTE CONTROL (ONLY FOR HRA DOMO)
V-TOUCH DIGITAL REMOTE CONTROL PANEL (ONLY FOR HRA DOMO)
BUILT-IN BOX FOR REMOTE TOUCH CONTROL PANEL (JUST FOR HRA DOMO)
ELECTRIC HEATING COIL
AMBIENT TEMPERATURE SENSOR
ACTIVE FILTER
2 SPARE FILTERS F7
BLACK OR WHITE WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL (ONLY FOR HRA DOMO)
HRA-I DOMOUnit for air renewal in heat pump
with active thermodynamic recovery and inverter combined
with passive recovery
HRA DOMO Active ventilation unit with recovery, integration, and
recirculation
free colling
* External air -5 °C / Internal air 20 °C ** External air 35 °C / Internal air 27 °C
TECHNICAL DATA u.m.
Renewal air flow rate m3/h
Recovery efficiency %
Energy efficiency class
Sound pressure at 3 m dB(A)
Air flow rate in cycle m3/h
HRW HRW X30/15
H50/25
H60/15
H90/25
H30/15
V50/25
V60/15
V90/25
V30/15
HX50/25
HX60/15
HX90/25
HX30/15
VX50/25
VX60/15
VX90/25
VX
154 265 155 263 161 258 160 261 162 282 154 270 163 264 163 264
85,7 86,0 86,6 86,5 83,9 86,0 84,0 85,9 75,3 74,0 75,4 74,1 75,2 75,0 75,2 75,0
B A B B B A B B B B C B B A B B
40,7 45,0 42,8 46,2 38,6 40,2 40,9 42,1 40,7 45,0 42,8 46,2 38,6 40,2 40,9 42,1
297 520 692 838 302 538 620 840 297 520 692 838 302 538 620 840
HRW Ventilation and air processing unit with the hidronic integration
ACCESSORIES HRW E HRW X
WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR
WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR WITH INTEGRATED WIFI MODULE
SONDA QUALITÀ ARIA
HUMIDISTAT
2-WAY VALVE ON/OFF
3-WAY VALVE ON/OFF
SUPPLY PLENUM FOR FLEXIBLE PIPES
SUPPLY PLENUM FOR CORRUGATED PIPES
ACTIVATED CARBON FILTER F7
SPARE FILTERS F7
HRW X Ventilation and air processing unit with the enthalpy heat exchanger
free cooling
SMART TOUCH control panel
AMBIENT AIR EXHAUSTEXPULSION
EXTERNAL AIR
AMBIENT AIR SUPPLY
AIR RECIRCULATION
EXPULSION
AMBIENT AIR INTAKE
EXTERNAL AIR
AMBIENT AIR SUPPLY EXPULSION
EXTERNAL AIR
AMBIENT AIR INTAKEAIR RECIRCULATION
weekly calendar with time bands
Max 31 units
HRHeat RecoveryVentilation
AirleafVertical/horizontal fancoil
FilomuroWall fancoil
FiloterraTrench fancoil
ALL IN ONE Autonomously meets thermal, cooling and ventilation room requirements.
INTEGRATED HYDRONIC COIL Integrated in the unit.
COMBINED AIR SUPPLY The total air supply consists of fresh air and recirculated air.
VENTILATIONHighly efficient brushless plug fans with low noise levels.
Versions: - with integrated NODBUS- with integrated WIFI- in black or white
Room control
Local PC
HELPS TO DEHUMIDIFY ROOMS IN THE SUMMER
HIGHLY EFFICIENT SUMMER AND WINTER RECOVERYThanks to the active thermodynamic recovery combined with passive recovery.
HEATING AND COOLINGGenerates an initial power step in heating and cooling.
DC INVERTER COMPRESSOR(HRA-I DOMO version)
BOCCHETTE ESTETICHE
ESSENTIAL WHITE
CHARCOAL WHITE WHITE GLASS OAK WOOD
Anti-static and antibacterial
corrugated pipe DN75 - DN90
ACCESSORIES
EXTERNAL GRILLS WALL MOUNTED
XTERNAL GRILLS WITH FLOW DEVIATION
JOINT WITH SEALING GASKETS
SLEEVES
REDUCTION WITH SEAL GASKETS
T FITTING WITH SEALING GASKETS
RIGID PIPES, 90° ANGLES AND SLEEVES MADE OG EPP
ANTI-STATIC AND ANTIBACTERIAL CORRUGATED PIPE
INSULATED FLEXIBLE DEAFENED PIPE
FIXING CLAMPS
ANTI-CONDENSATION TAPE
FLEXIBLE SILENCERS
PLENUM SILENCERS
UNIVERSAL MANIFOLDS 4x, 8x, 12x, 16x
CORRUGATED PIPE STARTS
STATIC AND DYNAMIC CAPACITY REGULATOR
O-RING
CAPS
CLIPS
INSULATING SHEATH FOR CORRUGATED PIPES
STEEL PLENUM
MULTI PURPOSEINSULATED PLENUM
PERFORATED GRILLS
SQUARED HOLES GRILLS
ATTRACTIVE VENTS
Multi purpose insulated plenum for intake and exhaust grills
HRC Decentralized heat recovery unit
Electronic version
Analog version
ACCESSORIES HRC
UNIT THERMAL ISOLATION KIT
ANGLE EXIT KIT
WALL MOUNTING CLAMP
WINDOW APPLICATION KIT FOR HELICAL EXTRACTOR FAN
AESTHETIC EXTERNAL GRILL
G3 FILTER REPLACEMENT
CERAMIC REGENERATOR REPLACEMENT
FRONT COVER
HRC
02 S 02 E 05 S 05 E
24 24 50 50
79 79 77 77
A A A A
28/26 28/26/23 32/26 32/26/18
- - - -
External grill Front cover
TECHNICAL DATA u.m.
Renewal air flow rate m3/h
Winter recovery efficiency %
Energy efficiency class
Sound pressure at 1 m (max/med/min) dB(A)
Air flow rate in cycle m3/h
HRDCompact heat recovery unit , dehumidification and air treatment with high efficiency heat recovery for application with radiant panels
HRD
30/15 V 40/20 V 50/25 V 60/30 V 30/15 H 40/20 H 50/25 H 60/30 H
161 204 258 319 154 199 265 316
83,9 81,5 86,0 81,8 85,7 81,2 86,0 81,8
22 30,5 40 56 22 30,5 40 31
B B A A B B A A
38,6 40,8 40,2 40,9 40,7 41,5 45,0 47,6
302 401 538 640 297 391 520 619
ACCESSORIES HRD
AUTOMATIC DIGITAL GRAPHIC REMOTE CONTROL PANEL
V-TOUCH DIGITAL REMOTE CONTROL PANEL
RECESSED BOX FOR ADVANCED DIGITAL TOUCH REMOTE CONTROL PANEL
2-WAYS VALVE ON/OFF
3-WAYS VALVE ON/OFF
SUPPLY CASING OF THE FLEXIBLE PIPES
SUPPLY CASING OF THE CORRUGATED PIPES
ACTIVATED CARBON FILTER F7
SPARE FILTERS F7
free cooling
TECHNICAL DATA u.m.
Renewal air flow rate m3/h
Winter recovery efficiency %
Capacità deumidifica L/24h
Energy efficiency class
Sound pressure at 3 m dB(A)
Air flow rate in cycle m3/h
HRPEHigh efficiency heat recovery unit for commercial applications
ACCESSORIES HRPE
2-WAYS VALVE ON/OFF
3-WAYS VALVE ON/OFF
HYDRONIC HEATING COIL
HYDRONIC COOLING COIL
ELECTRIC COIL
WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR (ALSO WITH INTEGRATED WIFI MODULE)
AIR QUALITY SENSOR
INNER SPACES HUMIDISTAT
RAIN COVER FOR EXTERNAL INSTALLATION
EXTERNAL COWL
SILENCER
HRPE H HRPE V
70 H 100 H 200 H 300 H 70 V 100 V 200 V 300 V 400 V 500 V
540 900 1980 2916 576 900 2160 2988 4068 5220
80,0 84,0 81,8 81,7 82,2 82,2 84,6 85,0 84,9 85,6
61,9 61,6 69,3 70,9 55,9 56,2 64,8 68,4 73,4 77,9
- - - - - - - - - -
bypass estivo e funzione free cooling
TECHNICAL DATA u.m.
Renewal air flow rate m3/h
Winter recovery efficiency %
Energy efficiency class
Sound pressure at 3 m dB(A)
Air flow rate in cycle m3/h
HRP DOMO HRP DOMO X
20 H 20 V 30 H 30 V 40 H 40 V 50 H 50 V 20 HX 20 VX 30 HX 30 VX 40 VX 50 VX
155 158 302 306 354 375 450 475 165 158 302 306 375 450
86,3 86,3 85,0 85,0 87,6 87,0 85,6 84,0 75.5 74.3 74 73.8 78 73.1
A A A A A A B A B B B B B B
40,8 38,6 41,7 41,0 42,6 38,4 47,6 44,4 40,8 38,6 41,7 41,0 38,4 47,6
- - - - - - - - - - - - - -
ACCESSORIES HRP DOMO and HRP DOMO X
ELECTRIC HEATING COIL
WATER HEATING COIL
2-WAY VALVE ON/OFF
3-WAY VALVE ON/OFF
AIR QUALITY SENSOR
HUMIDISTAT
SMART TOUCH CONTROL PANEL (WHITE OR BLACK)
SMART TOUCH WI-FI CONTROL PANEL (WHITE OR BLACK)
FLOOR MOUNTING KIT
ACTIVATED CARBON FILTER
SPARE FILTERS F7
HRP DOMO XHigh efficiency heat recovery unit with enthalpy heat exchanger
HRP DOMO High efficiency heat recovery unit
TECHNICAL DATA u.m.
Renewal air flow rate m3/h
Winter recovery efficiency %
Energy efficiency class
Sound pressure at 3 m dB(A)
Air flow rate in cycle m3/h
summer bypass efree cooling function
Variable lenght
EXPULSION
EXTERNAL AIR AMBIENT AIR INTAKE
AMBIENT AIR EXHAUST
EXPULSION
EXTERNAL AIR
AMBIENT AIR EXHAUST
AMBIENT AIR INTAKE
DUCTWORKSAccessories for ductworks
ADJUSTMENT Extremely high heat recovery.
AIR EXCHANGE Through-wall installation.
TWO CONTROL SYSTEMS For stand-alone or coordinated operation of the units.
REGENERATIVE HEAT RECOVERY Thanks to a ceramic exchanger and DC brushless fan with reversed cycle operation.
COMPLETEComplete ventilation unit with summer bypass and anti-freeze control.
AIR EXCHANGE AND PURIFICATIONHighly efficient air renewaland filtration with F7 filters.
RESIDENTIAL APPLICATIONSIdeal for single family units and apartments with nominal air flow rate less than 500 m3/h.
SMART TOUCH CONTROL PANELHighly attractive and functional wall-mounted remote control panel.
ALL IN ONE Autonomously fulfils heat recovery, dehumidification, cooling and heating requirements.
DC CONFIGURATION DC configuration for cooling integration.
COMBINED AIR SUPPLY The total air supply consists of fresh air and recirculated air.
VENTILATION Highly efficient brushless plug fans with low noise levels.
SLIMLINE Thanks to the slimline design, the horizontal version can be installed in false ceilings.
SERVICES SECTOR Ideal for use in services sector premises.
HIGH EFFICIENCY Over 90% recovery efficiency.
VENTILATION Ventilation unit including a heat recovery unit.