+ All Categories
Home > Documents > recovery, integration, and HRV recirculation

recovery, integration, and HRV recirculation

Date post: 05-Feb-2022
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
2
Punctual Passive Active thermodynamics Active hidronic With dehumidification Commercial Ductworks HRV Heat Recovery Ventilation INNOVA s.r.l. Via I Maggio 8, 38089 Storo - TN, ITALY T. +39 0465 670104 E: [email protected] www.innovaenergie.com Edizione | Edition 2019 AMBIENT AIR INTAKE BUTLER The web is at service of your home The BUTLER web server is a new INNOVA system to manage an entire air conditioning system from a local and remote network. BUTLER is powerful, simple and economic at the same time; It consists of a Web Server card integrated in a micro computer, which allows to connect the heat pumps, ventilation systems and fancoils, equipped with electronic controls with Modbus port, to a normal wired or wireless LAN. There fore is possible to con gure an entire system or individual fancoils networks to control them from a smart phone, tablet or computer via local or remote connection; it is also possible to set for each one: a weekly calendar with time slots, create zones, operating scenarios such as house, school, hotel, and etc. All the functions are executable without installation of an additional software in directing to an IP address or via an free of charge APP. HRA DOMO HRA-I DOMO 08 14 20 H 30 H 80 140 200 300 0,96 1,64 2,69 3,57 0,62 1,02 1,44 2,16 10,7 / 4,1 9,6 / 3,9 11,7 / 4,0 9,9 / 3,9 38 41 39 43 TECHNICAL DATA u.m. Renewal air flow rate m3/h Heating power * kW Cooling power ** kW COP / EER Sound pressure at 3 m dB(A) ACCESSORIES HRA DOMO & HRA-I DOMO AUTOMATIC DIGITAL GRAPHIC REMOTE CONTROL (ONLY FOR HRA DOMO) V-TOUCH DIGITAL REMOTE CONTROL PANEL (ONLY FOR HRA DOMO) BUILT-IN BOX FOR REMOTE TOUCH CONTROL PANEL (JUST FOR HRA DOMO) ELECTRIC HEATING COIL AMBIENT TEMPERATURE SENSOR ACTIVE FILTER 2 SPARE FILTERS F7 BLACK OR WHITE WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL (ONLY FOR HRA DOMO) HRA-I DOMO Unit for air renewal in heat pump with active thermodynamic recovery and inverter combined with passive recovery HRA DOMO Active ventilation unit with recovery, integration, and recirculation free colling * External air -5 °C / Internal air 20 °C ** External air 35 °C / Internal air 27 °C TECHNICAL DATA u.m. Renewal air flow rate m3/h Recovery efficiency % Energy efficiency class Sound pressure at 3 m dB(A) Air flow rate in cycle m 3 /h HRW HRW X 30/15 H 50/25 H 60/15 H 90/25 H 30/15 V 50/25 V 60/15 V 90/25 V 30/15 HX 50/25 HX 60/15 HX 90/25 HX 30/15 VX 50/25 VX 60/15 VX 90/25 VX 154 265 155 263 161 258 160 261 162 282 154 270 163 264 163 264 85,7 86,0 86,6 86,5 83,9 86,0 84,0 85,9 75,3 74,0 75,4 74,1 75,2 75,0 75,2 75,0 B A B B B A B B B B C B B A B B 40,7 45,0 42,8 46,2 38,6 40,2 40,9 42,1 40,7 45,0 42,8 46,2 38,6 40,2 40,9 42,1 297 520 692 838 302 538 620 840 297 520 692 838 302 538 620 840 HRW Ventilation and air processing unit with the hidronic integration ACCESSORIES HRW E HRW X WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR WITH INTEGRATED WIFI MODULE SONDA QUALITÀ ARIA HUMIDISTAT 2-WAY VALVE ON/OFF 3-WAY VALVE ON/OFF SUPPLY PLENUM FOR FLEXIBLE PIPES SUPPLY PLENUM FOR CORRUGATED PIPES ACTIVATED CARBON FILTER F7 SPARE FILTERS F7 HRW X Ventilation and air processing unit with the enthalpy heat exchanger free cooling SMART TOUCH control panel AMBIENT AIR EXHAUST EXPULSION EXTERNAL AIR AMBIENT AIR SUPPLY AIR RECIRCULATION EXPULSION AMBIENT AIR INTAKE EXTERNAL AIR AMBIENT AIR SUPPLY EXPULSION EXTERNAL AIR AMBIENT AIR INTAKE AIR RECIRCULATION weekly calendar with time bands Max 31 units HR Heat Recovery Ventilation Airleaf Vertical/horizontal fancoil Filomuro Wall fancoil Filoterra Trench fancoil ALL IN ONE Autonomously meets thermal, cooling and ventilation room requirements. INTEGRATED HYDRONIC COIL Integrated in the unit. COMBINED AIR SUPPLY The total air supply consists of fresh air and recirculated air. V E N T I L AT I O N Highly efficient brushless plug fans with low noise levels. Versions: - with integrated NODBUS - with integrated WIFI - in black or white Room control Local PC HELPS TO DEHUMIDIFY ROOMS IN THE SUMMER HIGHLY EFFICIENT SUMMER AND WINTER RECOVERY Thanks to the active thermodynamic recovery combined with passive recovery. HEATING AND COOLING Generates an initial power step in heating and cooling. DC INVERTER COMPRESSOR (HRA-I DOMO version)
Transcript

Punctual

Passive

Active thermodynamics

Active hidronic

With dehumidification

Commercial

Ductworks

HRVHeat

RecoveryVentilation

INNOVA s.r.l. Via I Maggio 8, 38089 Storo - TN, ITALY

T. +39 0465 670104E: [email protected]

www.innovaenergie.com

Edizione | Edition 2019

AMBIENT AIR INTAKE

BUTLERThe web is at service of your homeThe BUTLER web server is a new INNOVA system to manage an entire air conditioning system from a local and remote network. BUTLER is powerful, simple and economic at the same time; It consists of a Web Server card integrated in a micro computer, which allows to connect the heat pumps, ventilation systems and fancoils, equipped with electronic controls with Modbus port, to a normal wired or wireless LAN.

There fore is possible to con gure an entire system or individual fancoils networks to control them from a smart phone, tablet or computer via local or remote connection; it is also possible to set for each one: a weekly calendar with time slots, create zones, operating scenarios such as house, school, hotel, and etc. All the functions are executable without installation of an additional software in directing to an IP address or via an free of charge APP.

HRA DOMO HRA-I DOMO

08 14 20 H 30 H

80 140 200 300

0,96 1,64 2,69 3,57

0,62 1,02 1,44 2,16

10,7 / 4,1 9,6 / 3,9 11,7 / 4,0 9,9 / 3,9

38 41 39 43

TECHNICAL DATA u.m.

Renewal air flow rate m3/h

Heating power * kW

Cooling power ** kW

COP / EER

Sound pressure at 3 m dB(A)

ACCESSORIES HRA DOMO & HRA-I DOMO

AUTOMATIC DIGITAL GRAPHIC REMOTE CONTROL (ONLY FOR HRA DOMO)

V-TOUCH DIGITAL REMOTE CONTROL PANEL (ONLY FOR HRA DOMO)

BUILT-IN BOX FOR REMOTE TOUCH CONTROL PANEL (JUST FOR HRA DOMO)

ELECTRIC HEATING COIL

AMBIENT TEMPERATURE SENSOR

ACTIVE FILTER

2 SPARE FILTERS F7

BLACK OR WHITE WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL (ONLY FOR HRA DOMO)

HRA-I DOMOUnit for air renewal in heat pump

with active thermodynamic recovery and inverter combined

with passive recovery

HRA DOMO Active ventilation unit with recovery, integration, and

recirculation

free colling

* External air -5 °C / Internal air 20 °C ** External air 35 °C / Internal air 27 °C

TECHNICAL DATA u.m.

Renewal air flow rate m3/h

Recovery efficiency %

Energy efficiency class

Sound pressure at 3 m dB(A)

Air flow rate in cycle m3/h

HRW HRW X30/15

H50/25

H60/15

H90/25

H30/15

V50/25

V60/15

V90/25

V30/15

HX50/25

HX60/15

HX90/25

HX30/15

VX50/25

VX60/15

VX90/25

VX

154 265 155 263 161 258 160 261 162 282 154 270 163 264 163 264

85,7 86,0 86,6 86,5 83,9 86,0 84,0 85,9 75,3 74,0 75,4 74,1 75,2 75,0 75,2 75,0

B A B B B A B B B B C B B A B B

40,7 45,0 42,8 46,2 38,6 40,2 40,9 42,1 40,7 45,0 42,8 46,2 38,6 40,2 40,9 42,1

297 520 692 838 302 538 620 840 297 520 692 838 302 538 620 840

HRW Ventilation and air processing unit with the hidronic integration

ACCESSORIES HRW E HRW X

WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR

WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR WITH INTEGRATED WIFI MODULE

SONDA QUALITÀ ARIA

HUMIDISTAT

2-WAY VALVE ON/OFF

3-WAY VALVE ON/OFF

SUPPLY PLENUM FOR FLEXIBLE PIPES

SUPPLY PLENUM FOR CORRUGATED PIPES

ACTIVATED CARBON FILTER F7

SPARE FILTERS F7

HRW X Ventilation and air processing unit with the enthalpy heat exchanger

free cooling

SMART TOUCH control panel

AMBIENT AIR EXHAUSTEXPULSION

EXTERNAL AIR

AMBIENT AIR SUPPLY

AIR RECIRCULATION

EXPULSION

AMBIENT AIR INTAKE

EXTERNAL AIR

AMBIENT AIR SUPPLY EXPULSION

EXTERNAL AIR

AMBIENT AIR INTAKEAIR RECIRCULATION

weekly calendar with time bands

Max 31 units

HRHeat RecoveryVentilation

AirleafVertical/horizontal fancoil

FilomuroWall fancoil

FiloterraTrench fancoil

ALL IN ONE Autonomously meets thermal, cooling and ventilation room requirements.

INTEGRATED HYDRONIC COIL Integrated in the unit.

COMBINED AIR SUPPLY The total air supply consists of fresh air and recirculated air.

VENTILATIONHighly efficient brushless plug fans with low noise levels.

Versions: - with integrated NODBUS- with integrated WIFI- in black or white

Room control

Local PC

HELPS TO DEHUMIDIFY ROOMS IN THE SUMMER

HIGHLY EFFICIENT SUMMER AND WINTER RECOVERYThanks to the active thermodynamic recovery combined with passive recovery.

HEATING AND COOLINGGenerates an initial power step in heating and cooling.

DC INVERTER COMPRESSOR(HRA-I DOMO version)

BOCCHETTE ESTETICHE

ESSENTIAL WHITE

CHARCOAL WHITE WHITE GLASS OAK WOOD

Anti-static and antibacterial

corrugated pipe DN75 - DN90

ACCESSORIES

EXTERNAL GRILLS WALL MOUNTED

XTERNAL GRILLS WITH FLOW DEVIATION

JOINT WITH SEALING GASKETS

SLEEVES

REDUCTION WITH SEAL GASKETS

T FITTING WITH SEALING GASKETS

RIGID PIPES, 90° ANGLES AND SLEEVES MADE OG EPP

ANTI-STATIC AND ANTIBACTERIAL CORRUGATED PIPE

INSULATED FLEXIBLE DEAFENED PIPE

FIXING CLAMPS

ANTI-CONDENSATION TAPE

FLEXIBLE SILENCERS

PLENUM SILENCERS

UNIVERSAL MANIFOLDS 4x, 8x, 12x, 16x

CORRUGATED PIPE STARTS

STATIC AND DYNAMIC CAPACITY REGULATOR

O-RING

CAPS

CLIPS

INSULATING SHEATH FOR CORRUGATED PIPES

STEEL PLENUM

MULTI PURPOSEINSULATED PLENUM

PERFORATED GRILLS

SQUARED HOLES GRILLS

ATTRACTIVE VENTS

Multi purpose insulated plenum for intake and exhaust grills

HRC Decentralized heat recovery unit

Electronic version

Analog version

ACCESSORIES HRC

UNIT THERMAL ISOLATION KIT

ANGLE EXIT KIT

WALL MOUNTING CLAMP

WINDOW APPLICATION KIT FOR HELICAL EXTRACTOR FAN

AESTHETIC EXTERNAL GRILL

G3 FILTER REPLACEMENT

CERAMIC REGENERATOR REPLACEMENT

FRONT COVER

HRC

02 S 02 E 05 S 05 E

24 24 50 50

79 79 77 77

A A A A

28/26 28/26/23 32/26 32/26/18

- - - -

External grill Front cover

TECHNICAL DATA u.m.

Renewal air flow rate m3/h

Winter recovery efficiency %

Energy efficiency class

Sound pressure at 1 m (max/med/min) dB(A)

Air flow rate in cycle m3/h

HRDCompact heat recovery unit , dehumidification and air treatment with high efficiency heat recovery for application with radiant panels

HRD

30/15 V 40/20 V 50/25 V 60/30 V 30/15 H 40/20 H 50/25 H 60/30 H

161 204 258 319 154 199 265 316

83,9 81,5 86,0 81,8 85,7 81,2 86,0 81,8

22 30,5 40 56 22 30,5 40 31

B B A A B B A A

38,6 40,8 40,2 40,9 40,7 41,5 45,0 47,6

302 401 538 640 297 391 520 619

ACCESSORIES HRD

AUTOMATIC DIGITAL GRAPHIC REMOTE CONTROL PANEL

V-TOUCH DIGITAL REMOTE CONTROL PANEL

RECESSED BOX FOR ADVANCED DIGITAL TOUCH REMOTE CONTROL PANEL

2-WAYS VALVE ON/OFF

3-WAYS VALVE ON/OFF

SUPPLY CASING OF THE FLEXIBLE PIPES

SUPPLY CASING OF THE CORRUGATED PIPES

ACTIVATED CARBON FILTER F7

SPARE FILTERS F7

free cooling

TECHNICAL DATA u.m.

Renewal air flow rate m3/h

Winter recovery efficiency %

Capacità deumidifica L/24h

Energy efficiency class

Sound pressure at 3 m dB(A)

Air flow rate in cycle m3/h

HRPEHigh efficiency heat recovery unit for commercial applications

ACCESSORIES HRPE

2-WAYS VALVE ON/OFF

3-WAYS VALVE ON/OFF

HYDRONIC HEATING COIL

HYDRONIC COOLING COIL

ELECTRIC COIL

WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR (ALSO WITH INTEGRATED WIFI MODULE)

AIR QUALITY SENSOR

INNER SPACES HUMIDISTAT

RAIN COVER FOR EXTERNAL INSTALLATION

EXTERNAL COWL

SILENCER

HRPE H HRPE V

70 H 100 H 200 H 300 H 70 V 100 V 200 V 300 V 400 V 500 V

540 900 1980 2916 576 900 2160 2988 4068 5220

80,0 84,0 81,8 81,7 82,2 82,2 84,6 85,0 84,9 85,6

61,9 61,6 69,3 70,9 55,9 56,2 64,8 68,4 73,4 77,9

- - - - - - - - - -

bypass estivo e funzione free cooling

TECHNICAL DATA u.m.

Renewal air flow rate m3/h

Winter recovery efficiency %

Energy efficiency class

Sound pressure at 3 m dB(A)

Air flow rate in cycle m3/h

HRP DOMO HRP DOMO X

20 H 20 V 30 H 30 V 40 H 40 V 50 H 50 V 20 HX 20 VX 30 HX 30 VX 40 VX 50 VX

155 158 302 306 354 375 450 475 165 158 302 306 375 450

86,3 86,3 85,0 85,0 87,6 87,0 85,6 84,0 75.5 74.3 74 73.8 78 73.1

A A A A A A B A B B B B B B

40,8 38,6 41,7 41,0 42,6 38,4 47,6 44,4 40,8 38,6 41,7 41,0 38,4 47,6

- - - - - - - - - - - - - -

ACCESSORIES HRP DOMO and HRP DOMO X

ELECTRIC HEATING COIL

WATER HEATING COIL

2-WAY VALVE ON/OFF

3-WAY VALVE ON/OFF

AIR QUALITY SENSOR

HUMIDISTAT

SMART TOUCH CONTROL PANEL (WHITE OR BLACK)

SMART TOUCH WI-FI CONTROL PANEL (WHITE OR BLACK)

FLOOR MOUNTING KIT

ACTIVATED CARBON FILTER

SPARE FILTERS F7

HRP DOMO XHigh efficiency heat recovery unit with enthalpy heat exchanger

HRP DOMO High efficiency heat recovery unit

TECHNICAL DATA u.m.

Renewal air flow rate m3/h

Winter recovery efficiency %

Energy efficiency class

Sound pressure at 3 m dB(A)

Air flow rate in cycle m3/h

summer bypass efree cooling function

Variable lenght

EXPULSION

EXTERNAL AIR AMBIENT AIR INTAKE

AMBIENT AIR EXHAUST

EXPULSION

EXTERNAL AIR

AMBIENT AIR EXHAUST

AMBIENT AIR INTAKE

DUCTWORKSAccessories for ductworks

ADJUSTMENT Extremely high heat recovery.

AIR EXCHANGE Through-wall installation.

TWO CONTROL SYSTEMS For stand-alone or coordinated operation of the units.

REGENERATIVE HEAT RECOVERY Thanks to a ceramic exchanger and DC brushless fan with reversed cycle operation.

COMPLETEComplete ventilation unit with summer bypass and anti-freeze control.

AIR EXCHANGE AND PURIFICATIONHighly efficient air renewaland filtration with F7 filters.

RESIDENTIAL APPLICATIONSIdeal for single family units and apartments with nominal air flow rate less than 500 m3/h.

SMART TOUCH CONTROL PANELHighly attractive and functional wall-mounted remote control panel.

ALL IN ONE Autonomously fulfils heat recovery, dehumidification, cooling and heating requirements.

DC CONFIGURATION DC configuration for cooling integration.

COMBINED AIR SUPPLY The total air supply consists of fresh air and recirculated air.

VENTILATION Highly efficient brushless plug fans with low noise levels.

SLIMLINE Thanks to the slimline design, the horizontal version can be installed in false ceilings.

SERVICES SECTOR Ideal for use in services sector premises.

HIGH EFFICIENCY Over 90% recovery efficiency.

VENTILATION Ventilation unit including a heat recovery unit.


Recommended