DEPARTMENT OF THE ARMY -;. U.S. ARMY CENTER FOR HEALTH PROMOTION AND PREVENTIVE MEDICINE -" 5158 BLACKHAWK ROAD ABERDEEN PROVING GROUND, MARYLAND 21010-5422 REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 JUL 1998 MEMORANDUM FOR Commander, U.S. Army Forces Command, ATTN: AFPI-BC (Mr. Bonilla), Fort McPherson, GA 30330-6000 SUBJECT: Industrial Radiation Survey No. 27-MH-4939-R-97, Facility Close-Out and Termination Survey, Camp Kilmer, NJ, 1 July - 20 December 1997 I. Copies of subject report with Executive Summary are enclosed. Findings, recommendations, all specific requests by Department of. the Army Licensees, Camp Kilmer Base Realignment and Closure (BRAC) Office, U.S. Army Materiel Command, the State of New Jersey Bureau of Environmental Radiation, New Jersey Department of Environmental Protection, and the U.S." Environmental Protection Agency Region II representatives were addressed and staffed with the appropriate personnel assigned to support this project. II. The' final-laboratory analyses of wipe test samples were completed on 6 April 1998 for the Camp Kilmer BRAC building; Building 1072 and outdoor area bounded by Kilmer Road, Avenue "D", and the wooded area. FOR THE COMMANDER: Encd Program Manager Industrial Health Physics CF (w/encl): HQDA(DASA-ESOH/MR. FATZ) HQDA (DAIM-ED-R/MR. SCHROEDER) CDR, MEDCOM, ATTN: MCHO-CL-W (EXSUM ONLY) CDR, AMC, ATTN: AMCSF-P (2 CY) CDR, IOC, ATTN: AMSIO-DMS CDR, CECOM, ATTN: AMSEL-SF CDR, TACOM-ACALA, ATTN: AMSTA-AC-SF (2 CY) CDR, TACOM, ATTN: AMSTA-CZ' (2 CY) Readiness thru Health DEC I I 1998
Transcript
Page 1: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

DEPARTMENT OF THE ARMY -;.U.S. ARMY CENTER FOR HEALTH PROMOTION AND PREVENTIVE MEDICINE -"

5158 BLACKHAWK ROADABERDEEN PROVING GROUND, MARYLAND 21010-5422

REPLY TOATTENTION OF

MCHB-TS-OIP (40) 01 JUL 1998

MEMORANDUM FOR Commander, U.S. Army Forces Command, ATTN:AFPI-BC (Mr. Bonilla), Fort McPherson, GA30330-6000

SUBJECT: Industrial Radiation Survey No. 27-MH-4939-R-97,Facility Close-Out and Termination Survey, Camp Kilmer, NJ,1 July - 20 December 1997

I. Copies of subject report with Executive Summary are enclosed.Findings, recommendations, all specific requests by Department of.the Army Licensees, Camp Kilmer Base Realignment and Closure(BRAC) Office, U.S. Army Materiel Command, the State of NewJersey Bureau of Environmental Radiation, New Jersey Departmentof Environmental Protection, and the U.S." EnvironmentalProtection Agency Region II representatives were addressed andstaffed with the appropriate personnel assigned to support thisproject.

II. The' final-laboratory analyses of wipe test samples werecompleted on 6 April 1998 for the Camp Kilmer BRAC building;Building 1072 and outdoor area bounded by Kilmer Road, Avenue"D", and the wooded area.

FOR THE COMMANDER:

EncdProgram ManagerIndustrial Health Physics

CF (w/encl):HQDA(DASA-ESOH/MR. FATZ)HQDA (DAIM-ED-R/MR. SCHROEDER)CDR, MEDCOM, ATTN: MCHO-CL-W (EXSUM ONLY)CDR, AMC, ATTN: AMCSF-P (2 CY)CDR, IOC, ATTN: AMSIO-DMSCDR, CECOM, ATTN: AMSEL-SFCDR, TACOM-ACALA, ATTN: AMSTA-AC-SF (2 CY)CDR, TACOM, ATTN: AMSTA-CZ' (2 CY)

Readiness thru Health

DEC I I 1998

Page 2: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

U. S. Amy" center f&'" Health- P-xitioand Preventive edi e

U. . . . . . . . . . . . .. . ... S...-

INDUSTRIAL RADIATION SURVEY NO. 27-MH-4939-R-97FACILITY.CLOSE-OUT AND TERMINATION SURVEY

CAMP 'KILMER, NEW JERSEY1 JULY - 20 DECEMBER 1997

Distribution limited to U.S. Government agencies only;*protection of privileged information evaluating anothercommand;. Jun 98. Requests for this document must bereferred to Commander, U.S.. Army Forces Command, ATTN:AFPI-BC, Fort McPherson, GA 30330-6000.

Readiness Thru HealntsDESTRUCTION NOTICE -Destroy by any method that will prevent disclosure of contents or reconstruction of the document

Page 3: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

U.S. Army Center for Health Promotion and Preventive Medicine

The lineage of the U.S. Army Centerfor Health Promotion and Preventive Medicine(USACHPPM) •an be traced back over 50years. This organization began as the U.S. ArmyIndustrial Hygiene Laboratory, established during the industrial buildup for World War II, underthe direct superision of the Army Surgeon General. Its original location was at the Johns HopkinsSchool of Ilygiene and Public Health. Its mission was to conduct occupational health surveys andinvestigations within the Department of Dfense's (DOD's) industrial production base. It wasstaffed with three personnel and had a limited annual operating budget of three thousand dollars.

.Most recently, it became internationally known as the U.S. Army Environmental Hygiene Ageniy(AEHA). Its mission expanded to support worldwide preventive medicine programs of the Army,DOD, and other Federal agencies as directed by the Army Medical Command or the Office of TheSurgeon General, through consultations, support services, investigations, on-site visits, and training.

On I August 1994, AEHA was redesignated the U.S. Army Centerfor Health Promotion andPreventive Medicine with a provisional status and a commanding general officer. On I October1995, the nonprovisional status was approved with a mission of providing preventive medicine andhealth promotion leadership, direction, and services for America's Army.

The organization's quest has always been one of excellence and the provision of quality service.Today, its goal is to be an established world-class center of excellence for achieving and maintainingafit, healthy, and ready force. To achieve that end, the CHPPM holds firmly to its values whichare steeped in rich military heritage:

*. Integrity is the foundationExcellence is the standard

* Customer satisfaction is the focusIts people are the most valued resource

* Continuous quality improvement is the pathway

This organization stands on the threshold of even greater challenges and responsibilities. It has beenreorganized and reengineered to support the Army of the future. The CHPPM now has three directsupport activities located in Fort Meade, Maylanid; Fort McPherson, Georgia; and FitzsimonsAi~my Medical Center, Aurora, Colorado; to provide responsive regional health promotion andpreventive medicine support across the U.S. There are also two CHPPM overseas commands inLandstuhl, Germany and Camp Zama, Japan who contribute to the success of CHPPM'sincreasing global mission. As CHPPM moves into the 21st Century, new programs relating tofitness, health promotion, wellness, and disease surveillance are being added. As always, CHPPM*standsfirm in its commitment to Army readiness. It is an organization proud of its fine history,.yetequally excited about its challenging future.

Page 4: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

DEPARTMENT OF THE ARMYU.S. ARMY CENTER FOR HEALTH PROMOTION AND PREVENTIVE MEDICINE

5158 BLACKHAWK ROADABERDEEN PROVING GROUND, MARYLAND 21010-5422

REPLY TOATTENTON OF

EXECUTIVE SUMMARYINDUSTRIAL RADIATION SURVEY NO. 27-MH-4939-R-97

FACILITY CLOSE-OUT AND TERMINATION SURVEYCAMP KILMER, NEW JERSEY

1 JULY - 20 DECEMBER 1997

I. PURPOSE. This survey was conducted to determine the presenceand extent of radiological health hazards in Building 1072 andthe outdoor area bounded by Kilmer Road, Avenue "D," and thewooded area at Camp Kilmer. These areas are associated with theongoing Base Realignment and Closure actions at Camp Kilmer.This survey also verified that if any residual radioactivity isdetected in the areas surveyed, that it is in compliance with theNuclear Regulatory Commission and the State of New JerseyIndustrial Site f.otor~tizn Act guidelines for decontamination offacilities prior~o release for unrestricted use.

II. CONCLUSION. A review of the survey results indicates thatthere were no radiological health hazards identified as a resultof the use and storage of radioactive commodities in Building1072:or the outdoor area bounded by Kilmer Road, Avenue "D," andthe wooded area at Camp Kilmer.

III. RECOMMENDATION. Recommend the above mentioned building and.outdoor area be released for unrestricted use.

Readiness thru Health

Page 5: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-out andTermination Surv, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

TABLE OF CONTENTS

I. REFERENCES ...............................II. AUTHORITY ...............................III. PURPOSE ................................IV. GENERAL ................................V. BACKGROUND .............................

1. CHRONOLOGY ........................2. SITE CONDITION AT TIME OF SURVEY..3. POTENTIAL CONTAMINANTS AND RELEASE

VI. RADIATION SURVEYS AND RESULTS..........1. INSTRUMENTATION/EQUIPMENT .........2. INSTRUMENTATION SURVEY ............3. WIPE SAMPLING .....................4. SURVEY RESULTS ....................

VII. CONCLUSIONS ............................VIII.RECOMMENDATIONS .........................

......... o...Q....

................. 1

.............. o...

....... o.........1

.oo o u o l o e 2

GUIDELINES ....... 3....... o... ... .o . 3

.o.........o......o3

..... ..... ....... 6.3.. . .I . . ..3... . . .. ..4.. . .. . . .

APPENDICES

A References .............................................. A-IB Abbreviations ........................................... B-IC Buildings/Areas Surveyed, Radiological Survey Results.. .C-iD Release Guidelines ....................................... D-IE Instrumentation Used at Camp Kilmer ..................... E-IF Quality Assurance Results ................................. F-IG Instrument Quality Assurance Charts ..................... G-I

Page 6: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

.S ADEPARTMENT OF THE ARMYU.S. ARMY CENTER FOR HEALTH PROMOTION AND.PREVENTIVE MEDICINE

5158 BLACKHAWK ROAD

ABERDEEN PROVING GROUND, MARYLAND 21010-5422

REPLY TOATUEION OF

MCHB-TS-OIP

INDUSTRIAL RADIATION SURVEY NO. 27-MH-4939-R-97FACILITY CLOSE-OUT AND TERMINATION SURVEY

CAMP KILMER, NEW JERSEY1 JULY - 20 DECEMBER 1997

I. REFERENCES. See Appendix A for a list of references.

II. AUTHORITY. Facsimile, FORSCOM, AFPI-BC, .25 January 1996,subject: Forscom Priorities for the NRC and UXO BRAC 95Projects.

III. PURPOSE.

1. This survey was conducted to determine the presence andextent of radiological health hazards in Building 1072 and theoutdoor area bounded by Kilmer Road, Avenue "D," and the woodedarea. This building is associated with the ongoing BaseRealignment and Closure (BRAC) actions at Camp Kilmer.

2. This survey also verified that any residualradioactivity in Building 1072 and the outdoor area is incompliance with the Nuclear Regulatory Commission (NRC) and theState of New Jersey Industrial Site fl t 4&tL," Act (ISRA)

,0 guidelines for decontamination of f:alities prior to release forunrestricted use.

IV. GENERAL.

1. Meetings and briefings were conducted by Mr. JamesMullikin, Research Health Physics Technician, U.S. Army Centerfor Health Promotion and Preventive Medicine (USACHPPM) withMr. Richard Sample, BRAC Environmental Coordinator, Camp Kilmerand Mr. Samuel Bryant, BRAC Office, Camp Kilmer, to discuss thefindings and recommendations.

2. Project management for the close-out and terminationsurvey was conducted by the USACHPPM.

Readiness thru Health

Page 7: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

3. The survey was managed by Mr. Lorus L. Miller, SeniorHealth Physics Technician, Project Manager, and Mr. Mark S.Ditmore, Research Health Physics Consultant, Alternate ProjectManager. A team of health physics technicians performed thefield surveys.

4. The survey personnel from USACHPPM have varied expertisein radiological health issues and are qualified to perform thissurvey. Each individual was provided occupational health andsafety training at USACHPPM and at Camp Kilmer to administer asafe working environment.

5. Laboratory analyses were performed by the U.S. Air ForceArmstrong Labs, San Antonio, TX.

6. Quality Assurance (QA) was provided by an independent QAOfficer., Mr. Oscar James, Henry M. Jackson FoundationParticipant.

7. A list of abbreviations is found in Appendix B.

V. BACKGROUND.

1. Chronology.

a. The history of the use; storage and disposal ofradioactive material was documented in Industrial RadiationSurvey No. 27-MH-4939-H-96, Historical Data Review, Camp Kilmer,NJ, November 1996.

b. The USACHPPM survey team began preparation forperforming the Camp Kilmer radiological termination survey,July 1997.

c. The USACHPPM survey team prepared the sample protocoldocument, titled Industrial Radiation Survey Protocol No.27-MH-4939-P-97, Camp Kilmer, NJ, after being staffed through allinterested parties for comment, January 1998.

d. The USACHPPM survey team began the termination surveyof Camp Kilmer in accordance with (IAW) the above referencedprotocol from 1 July through 20 December 1997.

2

Page 8: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

q1_

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

2. Site Condition at Time of Survey.

a. Building 1072 was vacant when the survey began.However, trash and debris was not removed by the previousoccupants prior to this survey. Large pieces of furniture wererelocated-into unaffected areas of the building. The floor wasswept and the dust placed in recepticals inside of the buildinguntil results from the laboratory were obtained.

b. An unaffected room in Building 1072 was used as thebase of operations for the termination survey. The USACHPPMsurvey team used this room throughout the duration of theproject. This room in Building 1072 was surveyed aftercompletion of the project.

c. None of the survey units in Building 1072 wereidentified as having radiological contamination levels above thelimits specified by the NRC and State of New Jersey ISRA.

3. Potential Contaminants and Release Guidelines. SeeIndustrial Radiation Survey Protocol No. 27-MH-4939-P-97 for adetailed listing of potential radioactive materials at CampKilmer. The release guidelines for these potential contaminantsare listed in Appendix D.

VI. RADIATION SURVEYS AND RESULTS.

1. Instrumentation/Equipment.

a. A list of instruments are provided in Appendix E.The Minimum Detectable Activity (MDA) of each instrument issupplied with the instrument survey data in Appendix C.Efficiencies were determined with a radioisotope traceable to theNational Institute of Standards and Technology (NIST) which hadenergies similar to the energies of the isotopes used and storedat Camp Kilmer.

b. After calibration, an efficiency factor wascalculated for each alpha and beta instrument used during thissurvey. The efficiency factor was used to correlate the meterreading to the actual radioactivity present.

c. The alpha and beta gamma detectors used for thesurvey were 100 square centimeter (cm2 ) gas flow proportional

3

Page 9: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

t

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

detectors. The gamma probe used was a 1 inch x 1 inch sodiumiodide crystal. The equation used to convert counts per minute(cpm) to disintegrations per minute (dpm)/100 cm2 can be found inthe Nuclear Regulatory Guide (NUREG)/CR-5849, page 8.2, Section8.1.1.

d. The efficiency value for each instrument was used torecord the final reading into standardized regulatory criteriaexpressed in dpm per 100 cm2 . The monitoring values for grossalpha and gross beta-gamma in the tables of Appendix C arepresented in the converted values of dpm/100 cm2 .

e. The sensitivity of the gamma survey meter correlateswith NUREG/CR-5849, page 5-14, Table 5-6.

f. All portable survey meters were checked foroperability prior to packaging and shipping to Camp Kilmer, uponarrival at the survey site, before each day of surveying, middayof surveying, end of each day of surveying, and after anymalfunctions or repairs. Chapter 5, page 17, of the NUREG/CR-5849 was used for the field instruments as guidance foroperational checks. Instrument variation of + 2 sigma was usedas a standard.

(1) Alpha. Operational instrument checks were performedwith a NIST traceable thorium-230 source. All operational checkswere made at less than 0.5 centimeter (cm) from contact with thealpha source. The same procedures were used for each check toassure reproducibility.

*(2) Beta. Operational instrument checks were performedwith a NIST traceable technetium-99 source. All operationalchecks were made at less than 0.5 cm from the beta source. Thesame procedures were used for each check to assurereproducibility.

(3) Gamma. Operational instrument checks were performedwith a NIST traceable cesium-137 source. The same procedureswere used for each check to assure reproducibility.

2. Instrumentation Survey.

a. Instrumentation surveys were conducted within pre-established areas, as described by the termination survey

4

Page 10: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

protocol. The floor plan diagrams can be found in Appendix C.-Each area was scanned to determine the overall surfacecontamination. The fixed contamination (i.e., contaminationwhich is not detected by wipe test sample) is determined wheninstrumentation readings for alpha, beta-gamma and gammaradiation levels are taken at specified distances from thesurface area.

b. The survey grid system used alphanumeric designators.Grid rows would be designated by a letter and grid columnsdesignated by a number.

c. If a building and/or room was classified as anaffected area, survey grid size was set at 1 meter x 1 meter(Im x lm). If the area is classified affected non-uniform, itwas scanned 100%. If classified as affected uniform, then scanof approximately 100% was performed. Fixed meter readings weretaken at the center-of each grid for alpha, beta-gamma, and gammaactivity. If during scanning, a measured reading was found to begreater than three times the determined background, the areawould have been identified and marked; an instrumentation surveywould be performed to determine or to assess the fixedcontamination levels for alpha, beta-gamma radiation emitters.

d. If a building or room was classified as an unaffectedarea, a biased scan was performed over a minimum of 10% of thesurface area IAW the protocol. Typically, greater than 50% ofthe surface area of unaffected surfaces was scanned at CampKilmer. During scanning, if a measured reading was observed tobe greater than three times the determined background, the areawould be identified and marked; an instrumentation survey wouldbe performed to determine the fixed contamination levels foralpha, beta-gamma, and gamma radiation emitters. If nomeasurements were observed three times the determined background,the surveyors would take a minimum of 30 random appropriateinstrumentation readings to determine the fixed contaminationlevels in the area.

e. Each room was subdivided into ceilings, walls, andfloors, which were further divided into grid squares. Unusualbuilding features were surveyed in random locations and thehighest values observed were recorded.

5

Page 11: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

/7

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

f. All north walls were identified as Wall A (WA) andthe other walls were assigned consecutive letters in a clockwisemanner around the room (i.e., WB, WC, and WD). The grid squaresalways started in the lower left corner of the wall. The firstlower "lm x Im" (affected area) meter grid square was identifiedas "WAlA" and the grid square directly above was designated"WAIB", with B representing the next horizontal row on the wall.

g. Floors were gridded using a different system. Thegrid squares always started in the northwest corner of the floor.The northwest grid square was identified as FAl. The gridsquares to the east would be FA2, FA3, etc. The grid squares tothe south would be FBI, FC1, etc.

h. Flag values or action levels for alpha and beta-gammamonitoring measurements were established for each type of surveyinstrument used. Flag values were established by taking 75% ofthe'release criteria found in.Appendix D. If any instrumentreading exceeded the flag values, a more thorough investigationwas conducted to determine if the detected radiation was abovethe established criteria.

i. In addition to surveying the building surfaces,random readings were collected from physical features whereresidual radioactivity would likely be found. Cracks in wallsand floors, seams where walls met floors, holes in the walls,drains, vents, and other like areas were surveyed.

j. Readings observed above flag values were reported tothe onsite USACHPPM Health Physicist and the QA representativeimmediately, for reevaluation and confirmation. The USACHPPM'sQA representative reviewed the data for each surveyed area andevaluated the survey results in relationship to the survey gridsystem.

3. Wipe Sampling. Wipe tests were performed to determinethe presence of removable contamination on surface areas. Wipetest samples were collected from each grid square of all affectedand unaffected surfaces surveyed.

a. Cloth wipe test samples were collected using a2-inch diameter wipe pad to wipe an area of at least 100 cm2 .These samples were analyzed for alpha and beta-gamma removableactivity.

6

Page 12: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

b. Liquid Scintillation wipe samples were collectedusing a Metricel© filter, moistened with distilled water. Afterwiping the surface, the wipe test sample is placed in ascintillation cocktail in which the moistened filter dissolves.These samples were analyzed for low-energy beta emitters. The MDAof the worst case sample (highest MDA) for each survey unit isreported in appendix C.

c. When scanning, if a meter reading was observed to begreater than three times background radiation levels determinedfor the area, the area would be marked and surveyed for grossalpha, beta-gamma and low energy beta.

4. Survey Results.

a. Background Results. Building background measure-ments were taken from an area (IAW the Survey Protocol) of abuilding that has no history of radioactive material use.Background measurements were taken for each type of radiation tobe monitored. The average background values were established ata 95% confidence level.

(1) Background results for alpha radiation ranged from alow of 0.0 dpm/100 cm2 to a high of 30.5 dpm/100 cm2 with a meanof 13.1 dpm/100 cm2 . The MDA was 52 dpm/100 cm2 .

(2) Background results for beta-gamma radiation on thewalls ranged from a low of 401.5 dpm/100 cm2 to a high of 617dpm/100 cm2 with a mean of 507.5 dpm/100 cm2 . The MDA was 284dpm/100 cm2 . Background results for beta-gamma radiation on thefloor ranged from a low of 757.3 dpm/100 cm2 to a high of 978.9dpm/100 cm2 with a mean of 856.0 dpm/100 cm2 .

(3) Background results for gamma radiation taken at 1 mfrom any surface ranged from a low of 4.2 microRoentgen per hour(pR/hr) to a high of 7.1 pR/hr with a mean of 5.4 pR/hr.

(4) The outdoor area background measurements and soilsamples were taken from an area (IAW the Survey Protocol) of thecamp that had no history of radioactive material use. Gammaexposure measurements were taken at the background samplelocations. Soil samples were taken and analyzed for alpha, beta-gamma. Gamma isotopic analyses was performed for, radium-226

7

Page 13: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

C)

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

(Ra-226), thorium-232 (Th-232), and uranium-238 (U-238).Background samples were taken in an area bounded by Kilmer Road,Avenue "C," and Avenue "D".

(a) Background results for gamma radiation taken at 1 mfrom the surface ranged from a low of 13.2 pR/hr to a high of16.4 pR/hr with a mean of 15.4 pR/hr.

(b) Laboratory results of the background soil samplesfor alpha radiation ranged from a low of 3.60 picocurie per gram(pCi/g) to a high of 4.21 pCi/g with a mean of 3.81 pCi/g.

(c) Laboratory results of the background soil samplesfor beta-gamma radiation ranged from a low of 24.75 pCi/g to ahigh of 30.73 pCi/g with a mean of 27.79 pCi/g.

(d) Laboratory results of the background soil samplesfor Ra-226 ranged from a low of 0.00 :pCi/g to a high of 3.78pCi/g... with a mean of 0.94 pCi/g.

(e) Laboratory results of the background soil samplesfor Th-232 ranged from a low of 0.50 pCi/g to a high of 1.17pCi/g with a mean of 0.92. pCi/g.

(f) Laboratory results of the background soil samplesdid not indicate the presence of U-238.

b. Instrumentation Survey Results.

(1) Alpha Instrumentation Results. A fixed meterreading was taken in each grid square at less than 0.5 cm fromthe surface. The net alpha activity ranged from a low of -13 dpmper 100 cm2 (dpm/100 cm2) to a high of 38 dpm/100 cm2 abovebackground. All alpha activity results and location of surveyresults are presented in Appendix C.

(2) Beta-Gamma Instrumentation Results. A fixed meterreading was taken in each grid square at less than 0.5 cm fromthe surface. The net beta-gamma activity ranged from a low of-485 dpm/100 cm2 to a high of 891 dpm/100 cm2 above background.,-All beta-gamma survey results and locations are presented inAppendix C.

8

Page 14: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

(3) Gamma Instrumentation Results. Each grid square wassurveyed at approximately lm from the surface and the locationwith the highest exposure reading recorded. The net gammaactivity ranged from a low of -1.42 pR/hr to a high of 1.74 pR/hrabove background. All gamma survey results and locations arepresented in Appendix C.

(4) Scanning Instrumentation Results. One hundredpercent of the surface area of affected areas was scanned. Theprotocol states that a minimum of 10% of the surface area ofunaffected areas will be scanned. However, the unaffected areascans were typically performed over greater than 50% of thesurface area.

c. Laboratory Analysis. Wipe test samples werecollected and analyzed for gross alpha, gross beta-gamma, andtritium (H-3) activity. Blank wipe test samples were used toscreen for cross contamination and H-3 spikes were used as aquality control measure. These QA wipe results can be foundthroughout Appendix C.

(1) The gross alpha activity ranged from a low of -0.39dpm/100 cm2 to a high of 7.16 dpm/100 cm2 . The MDA at 95%confidence level was determined to be less than 2.5 dpm/100 cm2 .All gross alpha activity results and locations where wipe testswere taken are included in Appendix C. Gross alpha analysisshows no sample data that exceeds release criteria.

(2) The gross beta-gamma activity ranged from a low of-3.26 dpm/100 cm2 to a high of 15.10 dpm/100 cm2 . The MDA at 95%confidence level was determined to be less than 2.5 dpm/100 cm2 .All gross beta-gamma activity results and locations where wipetests were taken are included in Appendix C. Gross beta-gammaanalysis shows no sample data that exceeds release criteria.

(3) The H-3 activity at the 95% confidence level rangedfrom a low of -38.92 dpm/100 cm2 to a high of 63.87 dpm/100 cm2 .The H-3 results and locations where wipe tests were taken areincluded in Appendix C. The H-3 analysis shows no sample datathat exceeds release criteria.

9

Page 15: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

(4) Soil samples were collected from the outdoor area atCamp Kilmer and analyzed for alpha and beta-gamma radiation.Gamma isotopic analyses was performed for Ra-226, Th-232, andU-238.

(a) Gamma exposure rates at the location the soils weretaken from ranged from a low of 7.4 pR/hr to a high of 13.7pR/hr.

(b) Alpha radiation in the soil samples ranged from alow of 1.40 pCi/g to a high of 5.53 pCi/g.

(c) Beta-gamma radiation in the soil samples ranged froma low of 13.2 pCi/g to a high of 31.9 pCi/g.

(d) Isotopic analysis indicated that Ra-226 in the soilsamples ranged from a low of 0.00 pCi/g to a high of 2.34 pCi/g.

(e) Isotopic analysis indicated that Th-232 in the soilsamples ranged from a low of 0.00 pCi/g to a high of 1.31 pCi/g.

(f) Isotopic analysis indicated that U-238 in the soilsamples ranged from a low of 0.00 pCi/g to a high of 2.93 pCi/g.

(g) The concentrations of Ra-226, Th-232, and U-238 areat levels consistently found in the region of the site. Althoughno uranium was found in the background samples taken; it iswithin normal background levels for the region based on the datacollected during the National Uranium Resource Evaluation.

(5) Seven H-3 spikes and three blank samples weresubmitted to the Armstrong Laboratory with the samples taken inthe field as part of the QA efforts. The H-3 spikes wereprepared using counting media identical to the counting mediaused in the field. Activity of the QA samples ranged from 0 dpmadded to 997 dpm added. The average recovery rate for U.S. AirForce Armstrong Labs was 96.1%. The range of recovery for U.S.Air Force Armstrong Labs was from 86.8% to 100.6%. Blank clothwipes were also submitted as part of the QA process. The blankcloth wipes were used to screen for cross contamination. Allblank samples submitted had no detectable activity above thedetection limits.

10

Page 16: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, I Jul - 20 Dec 97

VII. CONCLUSION. A review of the survey results indicate thatthere were no radiological health hazards identified as a resultof the use and storage of radioactive commodities in Building1072 or the outdoor area bounded by Kilmer Road, Avenue "D" andthe wooded area at Camp Kilmer.

VIII. RECOMMENDATIONS. Recommend that the'surveyed building andthe outdoor area bounded by Kilmer Road, Avenue "D" and thewooded area listed above be released for unrestricted use.

o* /

J4A. DIAEýRResearch Health Physics ConsultantHenry M. Jackson Foundation ParticipantIndustrial Health Physics Program

APPROVED:

Program ManagerIndustrial Health Physics

11

Page 17: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

APPENDIX A

REFERENCES

1. NUREG/CR-5849, Manual for Conducting Radiological Surveys inSupport of License Termination, Draft Report for Comment,June 1992.

2. NRC Reg Guide 1.86, Termination of Operating Licenses forNuclear Reactors, June 1974.

3. AR 385-11, Ionizing Radiation Protection (Licensing, Control,Transportation, Disposal, and Radiation Safety), 1 May 1980.

4. Title 10, Code of Federal Regulations, Part 20, Standards forProtection Against Radiation, 1993 Rev.

5. Guidelines for Decontamination of Facilities and EquipmentPrior to Release for Unrestricted Use or Termination of Licensesfor Byproduct, Source, or Special Nuclear Material, August 1987.

6. NUREG-1500, Working Draft Regulatory Guide on ReleaseCriteria for Decommissioning: NRC Staff's Draft for Comment,August 1994.

7. Industrial Radiation Survey Protocol No. 27-MH-4939-P-97,Base Closure Plan, Camp Kilmer, NJ, 12 January 1997.

8. Industrial Radiation Survey No. 27-MH-4939-H-96, HistoricalData Review, Camp Kilmer, NJ, Nov 1996.

9. New Jersey Administrative Code 7:28-12, Remediation Standardsfor Radioactive Materials.

A-I

Page 18: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

APPENDIX B

ABBREVIATIONS

BRACcalcmcm

2

cpmdpmrH-3IAWISRAmMDANISTNRCNUREGpCi/gQARa-226Th-232USACHPPM

U-238pR/hr

Base Realignment and Closurecalibrationcentimeterssquare centimeter.counts per minutedisintegrations per minutetritiumin accordance withIndustrial Site Restoration ActmeterMinimum Detectable ActivityNational Institute of Standards and TechnologyNuclear Regulatory CommissionNuclear Regulatory Guidepicocurie per gramQuality Assuranceradium-226thorium-232U.S. Army Center for Health Promotion and

Preventive Medicineuranium-238microroentgen per hour

B-i

Page 19: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

APPENDIX C

LIST OF BUILDINGS SURVEYED

BUILDING DIAGRAMS

RADIOLOGICAL SURVEY RESULTS

Grids at '"lm x im" unless otherwise annotated

C-I

Page 20: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust, Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

BUILDINGS SURVEYED

1072Outdoor Area bounded by Kilmer Road, Avenue "D" and the woodedarea

C-2

Page 21: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

A

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

Ir*

AU

R:

zI=E

C' I

LUj

C/_=

I,

w

Cl)

LU_

LU

0)

C=7J

C-)

o~W

I-M0

= .. LUM

<LUPLEGEND FOR ROOMS LI

"1 THRU 9 TNG GP TNG GP TNG GP

AREAS OF INTEREST

RSTORAGE W TNGGP [ TNGGP 10_]OLD MOTOR POOL

TNG GP[8] TNG GP

C-3

Page 22: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 1072Room 1

WA ~ ~ ~ _ _j1 " I I A l

IWA VIA I I I I~.1A11

WD

Ic

VZO FA

F1FI

GARAGE DOOR

FA11

WeB

IA

_A

IC-

%7v9d

1FI

I111 1111 II. Ar

W.W. ýý le

I ý-I I II I I I I I IMC I

BUILDING 1072, ROOM 1. CAMP KILMER, NEW JERSEY DATE; 200CT97

DRAWN: MSD

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCALE: NTSUNITED STATES ARMY MEDICAL DEPARTMENT PLATE: NWA

C-4

Page 23: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 7-->MH-4939-R-97, Facility Close-ol->andTermination Surv, Cam, .3imer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM ILocation Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cmA2 dpnl00=cmA2 uRlhr dpmnlOOcmA2 +1- 2 sigma Number

(Bkgd=>) 5 0.0 to 0.33 0.9 to 1.18 7.86 to 7.9(MDA=>) 52 284 - 2.29 " 2.5 63.72FA1 2 -14 0 0.5 ± 1.2 -1.0 ± 1.6 -3.3 ± 8.8 LL01324FA2 2 -30 0 -0.1 ± 0.1 0.2 ± 2.0 -19.2 ± 18.2 LL01325FA3 -8 -50 0 -0.1 ± 0.1 0.6 ± 2.4 -17.7 ± 8.7 LL01326FA4 -13 71 0 -0.1 ± 0.1 -0.1 ± 2.0 -11.9 ± 10.6 LL01327FA5 -3 -119 0 -0.1 ± 0.1 0.2 ± 2.0 -17.0 ± 11.9 LL01328FA6 2 -127 0 0.5 ± 1.2 1.5 ± 2.7 -3.9 ± 10.4 LL01329FA7 -3 -79 0 -0.1 ± 0.1 -0.1 ± 2.0 -13.5 ± 10.0 LL01330FA8 12 -79 1 -0.1 ± 0.1 0.7 ± 2.2 -14.1 ± 11.7 LL01331FA9 -8 -147 1 -0.1 ± 0.1 1.1 ± 2.6 -11.2 ± 9.9 LL01332FA10 7 -10 1 -0.1 ± 0.1 1.7 ± 2.7 -11.9 ± 10.6 LL01333FAll -13 -147 1 -0.1 ± 0.1 0.7 ± 2.2 -18.7 ± 11.1 LL01334FB1 -3 -79 0 0.5 ± 1.2 -0.3 ± 2.0 -17.5 ± 9.9 LL01335FB2 -8 -42 1 -0.1 ± 0.1 -1.0 ± 1.6 -4.7 ± 10.7 LL01336FB3 2 -115 1 -0.1 ± 0.1 0.2 ± 2.0 -14.0 ± 10.3 LL01337FB4 -8 2 0 0.5 .± 1.2 0.6 ± 2.4 -17.3 ± 10.8 LL01338FB5 -8 -91 0 -0.1 ± 0.1 0.3 ± 2.2 -5.2 ± 11.8 LL01339FB6 7 66 0 -0.1 ± 0.1 0.2 ± 2.0 -14.3 ± 11.2 LL01340FB7 -3 -111 1 0.5 ± 1.2 -1.2 ± 1.6 -11.5 ± 10.2 LL01341FB8 -8 -22 1 -0.1 ± 0.1 0.3. ± 2.2 -12.5 ± 11.9 LL01342FB9 -8 -58 1 -0.1 ± 0.1 -0.2 ± 1.8 -10.2 ± 11.2 LL01343FB1O 7 -22 1 0.5 ± 1.2 -0.7 ± 1.8 -9.2 ± 10.9 LL01344FB11 -3 -62 0 -0.1 ± 0.1 -0.1 ± 2.0 -15.0 ± 13.3 LL01345FC1 -3 -26 1 -0.1 ± 0.1 0.7 ± 2.2 -10.6 ± 12.7 LL01346FC2 -8 -30 1 -0.1 ± 0.1 -0.3 ± 2.0 -2.3 ± 11.7 LL01347FC3 -8 -127 1 -0.1 ± 0.1 -1.0 ± 1.6 -15.2 ± 10.6 LL01348FC4 -3 58 1 0.5 ± 1.2 0.2 ± 2.0 -15.8 ± 11.0 LL01349FC5 2 -83 1 . -0.1 ± 0.1 0.2 ± 2.2 -11.1 ± 13.2 LL01350FC6 7 -30 1 0.5 ± 1.2 0.3 ± 2.2 -13.3 ± 10.4 LL01351FC7 2 -123 1 -0.1 ± 0.1 -1.6 ± 1.0 -16.9 ± 9.5 LL01352FC8 2 -151 0 -0.1 ± 0.1 -1.2 ± 1.6 -9.1 ± 11.8 LL01353FC9 2 -30 1 0.5 ± 1.2 -0.1 ± 2.0 -11.5 ± 10.2 LL01354FC10 2 -79 1 -0.1 ± 0.1 1.6 ± 2.5 -17.2 ± 11.3 LL01355FC11 -3 -147 1 -0.1 ± 0.1 2.0 ± 2.8 -10.9 ± 10.3 LL01356FD1 17 -42 0 -0.1 ± 0.1 0.8 ± 2.4 -14.5 ± 10.7 LL01357FD2 7 -83 0 -0.1 ± 0.1 -0.2 ± 1.8 -9.5 ± 12.3 LL01358FD3 2 10 0 -0.1 ± 0.1 -1.2 ± 1.6 -19.5 ± 10.5 LL01359FD4 12 -95 1 -0.1 ± 0.1 -1.5 ± 1.3 -13.8 ± 10.8 LL01360FD5 -8 -79 1 0.5 ± 1.2 -0.2 ± 1.8 -12.9 ± 10.1 LL01361FD6 -8 -83 1 -0.1 ± 0.1 -0.3 ± 2.0 -19.4 ± 12.8 LL01362FD7 -8 -119 1 0.5 ± 1.2 -0.6 ± 1.8 -13.6 ± 11.3 LL01363FD8 2 -62 1 -0.1 ± 0.1 1.1 ± 2.3 -11.2 ± 10.7 LL01364FD9 28 -268 0 -0.1 ± 0.1 -0.3 ± 2.0 -7.1 ± 11.2 LL01365FD10 2 58 1 1.1 ± 1.7 1.7 ± 2.7 -17.0 ± 11.9 LL01366FD11 -3 -34 0 -0.1 ± 0.1 0.7 ± 2.2 -15.5 ± 14.7 LL01367FE1 -3 22 0 -0.1 ± 0.1 -0.3 ± 2.0 -5.0 ± 11.4 LL01368FE2 -8 -26 0 0.5 ± 1.2 1.7 ± 2.7 -11.2 ± 10.7 LL01369FE3 2 -159 0 0.5 ± 1.2 3.3 ± 3.0 0.5 ± 12.9 LL01370FE4 -3 -42 0 0.5 ± 1.2 2.9 ± 3.1 -13.8 ± 12.3 LL01371FE5 -3 -26 1 -0.1 ± 0.1 -0.6 ± 1.8 -19.4 ± 12.8 LL01372FE6 -8 -139 1 -0.1 ± 0.1 0.2 ± 2.0 -15.4 ± 12.1 LL01373

C-4-1

Page 24: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2CmH-493l-R-97, Facility Close1-o7 OandTermination Surv, Carr ilmer, NJ, 1 Jul - 20 Dec 97)

Camp Kilmer, BUILDING 1072 ROOM 1Location _ _ Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/100cmA2 dpm/1OOcmA2 uPlhr dpm/100cmA2 +/-2 sigma Number

(Bkgd >) 5 0.0 to 0.33 0.9 to 1.18 7.86 to 7.9

(MDA >) 52 284 - 2.29 * 2.5 63.72 *

FE7 12 -22 1 0.5 ± 1.2 0.2 ± 2.2 -7.5 ± 10.7 LL01374FEB -3 -6 1 0.5 ± 1.2 1.3 ± 2.6 -14.9 ± 11.6 LL01375

FE9 -3 -107 1 -0.1 ± 0.1 1.1 ± 2.3 -9.2 ± 10.9 LL01376

FE10 -8 6 1 -0.1 + 0.1 2.4 ± 3.0 -11.9 ± 13.1 LL01377FEll 7 -66 1 -0.1 ± 0.1 0.3 ± 2.2 -5.8 ± 13.2 LL01378

FF1 -3 -139 0 0.5 ± 1.2 1.1 ± 2.3 -11.5 ± 10.2 LL01379FF2 -8 -211 0 -0.1 ± 0.1 1.5 ± 2.7 -8.8 ± 11.4 LL01380

FF3 -3 -87 1 1.7 ± 2.0 0.8 ± 2.4 -12.2 ± 10.2 LL01381

FF4 -13 -18 0 1.8 ± 2.1 0.7 ± 2.2 -23.9 ± 12.9 LL01382FF5 -8 -83 0. 0.5 ± 1.2 0.2 ± 2.2 -11.8 ± 12.0 LL01383

FF6 7 -14 0 -0.1 ± 0.1 -0.6 ± 1.8 -15.4 ± 12.1 LL01384FF7 7 -91 0 -0.1 ± 0.1 2.4 ± 2.8 -11.5 ± 10.2 LL01385FF8 2 -179 1 -0.1 ± 0.1 -1.2 ± 1.6 -14.9 ± 11.6 LL01386

FF9 -8 -187 1 -0.1 ± 0.1 2.6 ± 3.0 -18.4 ± 14.4 LL01387

FF10 -8 -167 1 -0.1 ± 0.1 2.0 ± 2.6 -16.5 ± 14.6 LL01388

FF11 -8 -38 0 -0.1 ± 0.1 -0.3 ± 2.0 -13.3 ± 13.6 LL01389

FG1 28 -143 0 1.1 ± 1.7 1.3 ± 2.6 -11.3 ± 11.6 LL01390

FG2 2 -99" 0 -0.1 ± 0.1 -0.2 ± 1.8 -12.1 ± 11.5 LL01391FG3 7 -143 1 1.1 ± 1.7 0.6 ± 2.4 -12.1 ± 11.5 LL01392

FG4 -13 -207 1 0.5 ± 1.2 3.1 ± 3.1 -9.1 ± 11.8 LL01393FG5 7 -58 1 0.5 ± 1.2 0.7 ± 2.2 -23.7 ± 16.5 LL01394FG6 -3 -207 1 1.7 ± 2.1 2.0 ± 2.8 -10.8 ± 15.3 LL01395

FG7 -13 -103 1 0.5 ± 1.2 -0.1 ± 2.0 -16.9 ± 12.5 LL01396

FG8 2 -135 1 -0.1 ± 0.1 -0.7 ± 1.6 -6.8 ± 8.9 LL01397

FG9 12 -155 1 -0.1 * 0.1 0.2 ± 2.2 -20.3 ± 12.0 LL01398FG10.4 7 -159 1 -0.1 ±* 0.1.. -1.0 ± 1.6 -14.5 ± 10.7 LL01399

FG11 -8 -6 0 1.2 ± 1.7 .1.1 ± 2.3 -17.9 ± 11.2 LL01400FH1 7 -42 0 -0.1 ± 0.1 -0.3 ± 2.0 -8.5 ± 11.0 LL01401FH2 -8 -75 1 -0.1 ± 0.1 1.3 ± 2.6 -3.5 ± 11.2 LL01402

FH-13 7 -107 0 -0.1 ± 0.1 1.1 ± 2.3 -5.5 ± 11.0 LL01403FH4 -3 -66 1 -0.1 ± 0.1 1.5 ± 2.7 -12.7 ± 9.4 LL01404FH5 7 -14 1 0.5 ± 1.2 2.6 ± 3.0 -11.2 ± .10.7 LL01405FH6 17 -159 0 -0.1 ± 0.1 1.1 ± 2.3 -6.7 ± 10.5 LL01406FH7 -3 -107 0 0.5 ± 1.2 1.5 ± 2.7 -6.9 ± 10.8 LL01407FH8 -3 -199 1 0.5 ± 1.2 -0.6 ± 1.8 -5.2 ± 10,3 LL01408

FH9 -8 -163 1 -0.1 ± 0.1 1.6 ± 2.5 -11.4 ± 12.6 LL01409

FH10 -13 -167 1 -0.1 ± 0.1 0.6 ± 2.4 -6.6 ± 11.7 LL01410

FH11 2 -139 0 1.1 ± 1.7 0.8 ± 2.4 -11.5 ± 10.2 LL01411

F11 2 -171 0 0.5 ± 1.2 0.2 ± 2.0 -13.7 ± 9.6 LL01412

F12 -3 -79 1 -0.1 ± 0.1 -1.2 ± 1.6 -5.5 ± 11.0 LL01413F13 -3 -131 0 0.5 ± 1.2 0.3 ± 2.2 -7.3 ± 10.4 LL01414

F14 -8 -107 0 0.5 ± 1.2 -1.1 ± 1.3 -7.5 ± 10.7 LL01415

FI5 -3 -30 0 -0.1 ± 0.1 1.1 ± 2.6 -8.9 ± 10.6 LL01416F16 -3 -18 1 0.5 ± 1.2 0.8 ± 2.4 -8.1 ± 11.5 LL01417

F17 17 -18 0 -0.1 ± 0.1 1.1 ± 2.3 -2.5 ± 9.9 LL01418FI8 2 -159 1 -0.1 ± 0.1 0.6 1 2.4 -7.9 ± 12.5 LL01419

FI9 -3 -58 1 3.0 ± 2.6 -1.5 ± 1.3 -7.8 ± 11.1 LL01420

FI10 -8 -10 0 -0.1 ± 0.1 0.2 ± 2.0 -21.5 ± 17.9 LL01421

Flll -3 -75 0 0.5 ± 1.2 -0.3 ± 2.0 -16.6 ± 13.8 LL014220A NIA N/A N/A -0.1 ± 0.1 1.3 ± 2.6 -0.1 ± 6.9 LL01423

C-4-2

Page 25: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2-N--H-4939-R-97, Facility Close-ot"°'andTermination Surv, Camp &lmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM ILocation Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/1OOcmA2 dpn1O00cmA2 uR/hr dpm/100cmA2 -1-2 sigma Number

(Bkgd =>) 5 0.0 to 0.33 0.9 to 1.18 7.86 to 7.9(MDA=) 52 284 - 2.29 . 2.5 - 63.72 *WAIA 23 -300 0 -0.1 ± 0.1 -0.2 ± 1.8 -4.7 ± 7.4 LL01424WA2A 2 -240 0 -0.1 ± 0.1 0.6 ± 2.4 -8.8 ± 6.9 LL01425WA3A -13 -324 0 -0.1 ± 0.1 -0.1 ± 2.0 -0.6 ± 7.8 LL01426WA4A -8 -252 1 -0.1 ± 0.1 -0.7 ± 1.6 -3.6 ± 8.1 LL01427WA5A 7 -216 1 -0.1 ± 0.1 1.5 ± 2.7 -4.2 ± 7.4 LL01428WA6A 28 -191 1 -0.1 ± 0.1 1.3 ± 2.6 -1.9 ± 7.5 LL01429WA7A -13 -187 1 -0.1 ± 0.1 -0.7 ± 1.6 -2.6 ± 8.2 LL01430WA8A -3 -312 1 -0.1 ± 0.1 -0.7 ± 1.8 -4.6 ± 7.2 LL01431WA9A 2 -175 1 1.1 ± 1.7 -0.6 ± 1.8 -4.1 ± 7.3 LL01432WA10A -3 -147 1 -0.1 ± 0.1 0.2 ± 2.0 -7.2 ± 6.9 LL01433WA11A 2 -171 1 -0.1 ± 0.1 -0.3 ± 2.0 -6.2 ± 7.4 LL01434WA1B 2 -284 0 -0.1 ± 0.1 0.8 ± 2.4 -5.0 ± 7.2 LL01435WA2B 7 -292 1 -0.1 ± 0.1 -1.1 ± 1.3 -5.1 ± 7.3 LL01436WA3B -13 -284 0 -0.1 ± 0.1 -0.3 ± 2.0 -4.1 ± 7.3 LL01437WA4B 17 -292 1 -0.1 ± 0.1 0.3 ± 2.2 -3.6 ± 7.2 LL01438WA5B 7 -284 1 -0.1 ± 0.1 -0.2 ± 1.8 0.8 ± 8.0 LL01439WA6B -3 -348 1 -0.1 ± 0.1 -0.7 ± 1.8 -5.4 ± 8.5 LL01440WA7B 2 -171. 0 0.5 ± 1.2 2.2 ± 2.9 -8.6 ± 6.7 LL01441WA8B 7 -280 1 0.5 + 1.2 1.1 ± 2.3 1.7 ± 8.1 LL01442WA9B -8 -216 1 -0.1 ± 0.1 -1.6 ± 2.0 -4.1 ± 7.3 LL01443WA10B -8 -183 0 -0.1 ± 0.1 0.1 ± 2.7 -3.7 ± 7.3 LL01444WA11B 17 -324 0 0.7 ± 1.5 0.1 ± 2.7 -2.4 ± 7.5 LL01445WAIC -8 -336 0 -0.1 ± 0.1 1.7 ± 3.3 -3.3 ± 7.5 LL01446WA2C 7 -272 0 -0.1 ± 0.1 -1.6 ± 2.0 -4.6 ± 7.2 LL01447WA3C 12 -268 1 -0.1 ± 0.1 0.1 ± 2.7 -4.9 ± 7.0 LL01448WA4C .2 -308 0 -0.1 ± 0.1 -0.5 ± 2.5 -6.4 ± 7.0 LL01449WA5C -3 -195 0 -0.1 ± 0.1 1.2 ± 3.1 -6.2 ± 7.4 LL01450WA6C 7 -332 0 1.5 ± 2.2 0.6 ± 2.9 -5.9 ± 7.0 LL01451WA7C -13 -244 1 0.7 + 1.5 -1.1 ± 2.3 -1.0 ± 7.6 LL01452WABC 12 -244 1 -0.1 ± 0.1 5.0 ± 4.2 -4.1 ± 7.3 LL01453WA9C -8 -147 0 -0.1 ± 0.1 -1.1 ± 2.3 -5.9 ± 7.0 LL01454WA10C 2 -207 0 -0.1 + 0.1 0.1 ± 2.7 -5.1 ± 7.3 LL01455WA11C 17 -268 0 -0.1 ± 0.1 -1.1 ± 2.3 -4.1 ± 7.3 LL01456WBIA -8 -300 1 -0.1 ± 0.1 -0.5 ± 2.5 -2.4 ± 7.6 LL01457WB2A -3 -308 1 -0.1 ± 0.1 0.1 ± 2.7 -5.6 ± 7.3 LL01458WB3A -3 -312 1 -0.1 ± 0.1 0.6 ± 2.9 -4.2 ± 7.4 LL01459WB4A -8 -191 1 -0.1 ± 0.1 0.6 ± 2.9 -2.5 ± 7.8 LL01460WB5A 2 -240 1 -0.1 ± 0.1 1.7 ± 3.3 -1.6 ± 8.1 LL01461WB6A 2 -248 1 -0.1 ± 0.1 0.6 * 2.9 -4.9 ± 7.7 LL01462WB7A -3 -232 1 -0.1 ± 0.1 0.6 ± 2.9 -6.1 ± 7.2 LL01463WB8A -3 -103 1 -0.1 ± 0.1 -1.6 ± 2.0 -5.1 ± 7.3 LL01464WB9A -13 -276 1 -0.1 ± 0.1 1.2 ± 3.1 -5.7 ± 7.4 LL01465WB1B 2 -240 0 -0.1 ± 0.1 1.2 ± 3.1 -5.5 ± 7.8 LL01466 -

WB2B 2 -207 1 2.2 ± 2.6 -1.1 ± 2.3 -7.0 ± 7.1 LL01467WB3B -3 -240 1 -0.1 ± 0.1 1.2 ± 3.1 -3.7 ± 7.3 LL01468WB4B 2 -280 1 0.7 ± 1.5 -0.5 ± 2.5 -4.7 ± 7.4 LL01469WB5B -8 -288 1 -0.1 ± 0.1 0.6 ± 2.9 -5.4 ± 6.9 LL01470WB6B 12 -175 1 -0.1 ± 0.1 -1.1 ± 2.3 -4.9 ± 7.0 LL01471WB7B -3 -151 1 -0.1 ± 0.1 -0.5 ± 2.5 1.1 ± 7.2 LL01472WBBB -8 -248 0 0.7 ± 1.5 -0.5 ± 2.5 -2.4 ± 7.5 LL01473

C-4-3

Page 26: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-opt.andTermination Surv, Cam./ imer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM ILocation Monitoring i 1 Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cm^2 dpml00=cmA2 uRlhr dpmI100cmA2 +/-2 sigma Number

(Bkgd >) 5 0.0 to 0.33 0.9 to 1.18 7.86 to 7.9

(MDA>) 52 284 - 2.29 * 2.5 - 63.72 _

WVB9B 7 -187 1 -0.1 + 0.1 -1.1 ± 2.3 -5.9 + 7.0 LL01474WB1C -8 -220 1 -0.1 ± 0.1 2.8 ± 3.6 0.3 ± 7.9 LL01475WB2C 2 -316 1 -0.1 ± 0.1 -1.1 ± 2.3 -3.3 ± 7.5 LL01476WB3C 2 -211 1 -0.1 ± 0.1 -0.5 ± 2.5 1.7 ± 8.1 LL01477

WB4C 7 -187 0 -0.1 ± 0.1 0.6 ± 2.9 1.6 ± 7.7 LL01478WB5C 2 -296 0 -0.1 ± 0.1 -0.5 ± 2.5 20.3 ± 9.5 LL01479WB6C -8 -139 0 -0.1 ± 0.1 -1.1 ± 2.3 0.3 ± 7.6 LL01480WB7C 17 -236 0 -0.1 ± 0.1 -1.1 ± 2.3 7.0 ± 8.5 LL01481WB8C 7 -131 0 -0.1 ± 0.1 1.7 ± 3.3 5.6 ± 8.3 LL01482VVB9C 7 -216 0 -0.1 ± 0.1 0.6 ± 2.9 -0.6 ± 7.7 LL01483WC1A 2 -203 1 -0.1 ± 0.1 1.2 ± 3.1 7.1 ± 8.7 LL01484WC2A -3 -316 1 0.7 ± 1.5 0.1 ± 2.7 2.1 ± 8.0 LL01485WC3A -3 -236 0 "-0.1 ± 0.1 -0.5 ± 2.5 -4.8 ± 7.5 LL01486WC4A 12 -171 0 -0.1 ± 0.1 -1.1 ± 2.3 -4.6 ± 7.2 LL01487

WC5A -13 -328 0 1.0 ± 1.8 -1.2 ± 1.8 -5.0 ± 7.2 LL01488WC6A 7 -183 0. -0.4 ± 0.2 0.8 ± 2.7 1.2 ± 8.0 LL01489WC7A 23 -195 1 0.3 ± 1.3 -1.2 ± 1.8 2.9 ± 7.9 LL01490WC8A 2 -163 0 -0.4 ± 0.2 -0.2 ± 2.3 2.9 ± 7.9 LL01491WC9A ... 7 -256 -1 0.3 ± 1.3 2.3 ± 3.2 -1.0 ± 7.4 LL01492

WC10A.. 12 -248 0 -0.4 ± 0.2 0.8 ± 2.7 -1.4 ± 7.4 LL01493WC11A 12 -256 0 -0.4 ± 0.2 0.3 ± 2.5 4.8 ± 8.2 LL01494WC1B -3 -316 0 -0.4 ± 0.2 -0.2 ± 2.3 -1.2 ± 8.6 LL01495WC2B1 2 -320 0 1.0 ± 1.8 -1.2 ± 1.8 6.7 ± 8.6 LL01496WC3B -8 -276 1 -0.4 ± 0.2 1.3 ± 2.8 8.1 ± 8.4 LL01497WC4B . -8 -252 0 1.0 ± 1.8 -0.7 ± 2.0 -1.8 ± 7.2 LL01498WC5B ,. 12 -203 0 -0.4OA 0.2 0.3 ± 2.5 3.8 ± 8.0 LL01499WC6B 2 -207 0 1.6 ± 2.2 1.3 ± 2.8 0.7 ± 7.5 LL01500WC7B -8 -312 1 0.3 ± 1.3 -0.2 ± 2.3 1.3 ± 8.2 LL01501WC8B 2 -220 1 -0.4 ± 0.2 -1.2 ± 1.8 30.7 ± 10.4 LL01502WC9B 2 -220 0 -0.4 ± 0.2 0.3 ± 2.5 -1.4 ± 7.4 LL01503WC10B -3 -272 0 -0.4 ± 0.2 2.9 t 3.3 4.6 ± 7.9 LL01504WC11B -13 -187 0 1.6 ± 2.2 1.8 ± 3.0 4.1 ± 7.8 LL01505WC1C 2 -211 0 -0.4 * 0.2 1.8 ± 3.0 -5.7 ± 9.0 LL01506WC2C 23 -272 0 4.2 ± 3.4 7.4 ± 4.5 0.4 ± 8.7 LL01507WC3C 7 -216 0 -0.4 ± 0.2 1.8 ± 3.0 6.7 ± 8.1 LL01508WC4C -3 -228 0 0.3 ± 1.3 4.9 + 3.9 9.4 ± 35.8 LL01509WC5C 7 -216 0 0.3 ± 1.3 -0.7 ± 2.0 -5.7 ± 15.2 LL01510WC6C -8 -260 0 2.3 ± 2.6 3.9 ± 3.6 3.1 ± 8.2 LL01511WC7C -3 -308 0 0.3 ± 1.3 3.4 ± 3.5 2.1 ± 8.1 LL01512WC8C 12 -171 1 -0.4 ± 0.2 3.4 ± 3.5 1.2 ± 7.9 LL01513WC9C -3 -252 1 -0.4 ± 0.2 -0.2 ± 2.3 6.8 ± 8.3 LL01514WC10C -3 -292 0 1.0 ± 1.8 -1.2 ± 1.8 1.8 ± 8.7 LL01515WC11C 2 -280 -1 -0.4 ± 0.2 0.8 ± 2.7 0.4 ± 9.2 LL01516WD1A 2 -312 0 0.3 ± 1.3 1.8 ± 3.0 -0.2 ± 10.2 LL01517WD2A -8 -284 0 0.3 ± 1.3 5.4 ± 4.0 4.6 ± 9.6 LL01518WD3A 7 -284 0 -0.4 ± 0.2 0.8 ± 2.7 -0.1 ± 7.7 LL01519WD4A 2 -324 0 -0.4 ± 0.2 2.9 ± 3.3 -3.3 ± 7.5 LL01520WD5A -3 -216 0 1.0 ± 1.8 2.9 ± 3.3 5.3 t 8.5 LL01521VVD6A -3 -252 0 -0.4 ± 0.2 -0.7 ± 2.0 -2.3 ± 7.3 LL01522WD7A 7 -91 0 -0.4 ± 0.2 -1.7 ± 1.5 5.5 ± 8.1 LL01523

C-4-4

Page 27: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2'-MH-4939-R-97, Facility Close-ov'-ndTermination Surv, Camp .lmer, NJ, 1 Jul - 20 Dec 97

, Camp Kilmer, BUILDING 1072 ROOM ILocation Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/100cmA2 dpmr/100cA^2 uRlhr dpm/100cm^2 +1-2 sigma Number(Bkgd >) 5 0.0 - to 0.33 0.9 to 1.18 7.86 to 7.9

(MDA =) 52 284 . 2.29 * 2.5 63.72 *WD8A 2 -224 0 -0.4 ± 0.2 0.8 ± 2.7 - -1.4 ± 7.4 LL01524WD9A 7 -272 0 -0.4 ± .0.2 -1.2 ± 1.8 2.0 ± 7.8 " LL01525WD1B -3 -361 0 -0.4 ± 0.2 0.8 ± 2.7 -5.8 ± 8.3 LL01526WD2B -8 -300 0 -0.4 t 0.2 -0.2 ± 2.3 3.6 ± 8.5 LL01527WD3B -8 -232 -1 -0.4 ± 0.2 0.3 ± 2.5 0.3 ± 8.3 LL01528WD4B -8 -232 0 -0.4 ± 0.2 1.8 ± 3.0 -4.3 ± 7.6 LL01529WD5B 7 -199 0 0.3 ± 1.3 -0.7 ± 2.0 -3.2 ± 7.4 LL01530WD6B -8 -264 0 -0.4 ± 0.2 2.3 ± 3.2 1.6 ± 7.7 LL01531WD7B -3 -163 0 -0.4 ± 0.2 1.3 ± 2.8 -0.1 ± 7.9 LL01532WD8B 17 18 -1 1.6 ± 2.2 3.9 ± 3.6 -4.2 ± 7.4 LL01533WD9B 12 -155 0 -0.4 ± 0.2 2.3 ± 3.2 -1.5 ± 7.6 LL01534

WD1C 7 -252 0 4.2 ± 3.4 0.3 ± 2.5 -1.7 ± 8.7 LL01535WD2C 2 -264 0 -0.4 ± 0.2 2.3 ± 3.2 -10.2 ± 8.5 LL01536WD3C 17 -260 0 2.3 ± 2.6 4.9 ± 3.9 -0.8 ± 10.4 LL01537WD4C -8 -276 0 1.0 ± 1.8 -0.2 ± 2.3 1.3 ± 8.2 LL01538WD5C -8 -107 -1 1.0 ± 1.8 -0.2 ± 2.3 -4.0 ± 7.1 LL01539WD6C -8 -151 0 1.6 ± 2.2 1.3 ± 2.8 -4.5 ± 7.0 LL01540WD7C -3 -155 1 0.3 ± 1.3 0.3 ± 2.5 2.2 ± 10.5 LL01541WDSC 12 -256 1 -0.4 ± 0.2- 0.8 ± 2.7 -1.2 ± 9.0 LL01542WD9C 2 -131 0 -0.4 ± 0.2 0.3 ± 2.5 -3.2 ± 7.2 LL01543

0A N/A N/A N/A 0.3 ± 1.3 0.8 ± 2.7 27.3 ± 9.4 LL01544

Indicates the highest MDA for this survey unit. The Alpha MDA ranged from 1.78*to 2.29 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.9 to 2.5 dpm

Indicates the highest MDA for this survey unit. The H-3 MDA ranged from 12.49 to 63.72 dpm

C-4-5

Page 28: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 1072Room 3

WA WA'C .WA WA

WAWA

IA_.A

mo v-41_I_41WD WD2~

~FA~l 1i~i4-FAFD FD

ILC IJc

1tA 1 ]

IA IC

W8 a4A 4C

S

BUILDING 1072. ROOM 3. CAMP KILMER. NEWJERSEY DATE, 20 OCT97

DRAWN: MSD

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCALE: NTSUNITED STATES ARMY MEDICAL DEPARTMENT PLATE: W/A

C-5

Page 29: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2"•2H-4939-R-97, Facility Close-ovi ndTermination Surv, Camp. .ilmer, NJ, 1 Jul - 20 Dec 97 .

Camp Kilmer, BUILDING 1072 ROOM 3Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpmlOOcrn^2 dpmr/1OOcMAn2 uR/hr dpm/1O0cm*2+1- 2 sigma Number(Bkgd =>) 5 0.0 to 0.33 1.07 to 1.18 7.86 to 7.9

(MDA=>) 52 284 - 2.29 " 2.5 " 27.7

FA1 12 75 0 -0.4 ± 0.2 0.8 ± 2.7 -8.7 ± 9.5 LL01545FA2 12 -54 0 -0.4 ± 0.2 0.8 ± 2.7 -7.4 ± 11.6 LL01546FA3 -8 119 0 -0.4 ± 0.2 2.3 t 3.2 -8.8 ± 11.4 LL01547FA4 2 -131 0 1.6 ± 2.2 1.3 ± 2.8 -9.1 ± 11.8 LL01548FA5 7 10 1 1.0 ± 1.8 0.8 ± 2.7 -9.2 ± 10.1 LL01549FA6 -3 107 1 -0.4 ± 0.2 1.3 ± 2.8 -5.6 ± 9.9 LL01550FA7 -8 -71 0 -0.4 ± 0.2 -1.7 ± 1.5 -3.6 ± 9.5 LL01551FA8 -8 54 1 -0.4 ± 0.2 1.3 ± 2.8 -4.8 ± 8.4 LL01552FA9 -3 -26 0 -0.4 ± 0.2 0.3 ± 2.5 -5.5 ± 9.6 LL01553FA10 -3 -42 2 -0.4 ± 0.2 1.3 ± 2.8 -4.4 ± 10.0 LL01554FAll 2 -30 1 -0.4 ± 0.2 -0.2 E 2.3 -5.6 ± 9.9 LL01555FB1 2 22 1 0.3 ± 1.3 -1.2 ± 1.8 -7.5 ± 10.7 LL01556FB2 2 26 1 -0.4 ± 0.2 3.9 ± 3.6 -6.0 ± 8.5 LL01557FB3 2 -30 1 0.3 ± 1.3 0.3 ± 2.5 -5.0 ± 11.4 LL01558FB4 12 10 1 -0.4 ± 0.2 0.8 ± 2.7 -3.8 ± 12.0 LL01559FB5 12 10 0 -0.4 ± 0.2 1.3 ± 2.8 -10.6 ± 12.7 LL01560FB6 2 -50 0 -0.4 ± 0.2 1.8 ± 3.0 -15.2 ± 10.6 LL01561FB7 -3 26. 1 -0.4 ± 0.2 1.8 ± 3.0 -4.9 ± 11.0 LL01562FB8 12 26 1 0.3 ± 1.3 3.4 ± 3.5 -2.6 ± 10.2 LL01563FB9 7 -95 2 0.3 ± 1.3 1.8 ± 3.0 -9.2 ± 10.9 LL01564FB10 -3 -18 1 0.3 ± 1.3 -2.2 ± 1.1 -7.7 ± 10.0 LL01565FB11 7 -34 1 -0.4 ± 0.2 -0.7 ± 2.0 -5.8 ± 10.2 LL01566FC1 -8 30 0 0.3 ± 1.3 0.3 ± 2.5 -10.5 ± 9.3 LL01567FC2 -3 -34 0 0.3 ± 1.3 -0.2 ± 2.3 -5.6 ± 9.9 LL01568FC3 -8 -18 0 0.3 * 1.3 3.4 ± 3.5 -6.8 ± 8.9 LL01569FC4 -3 22 0 -0.4 ± 0.2 -0.2 ± 2.3 -16.2 ± 12.0 LL01570FC5 -8 34 1 -0.4 ± 0.2 0.8 ± 2.7 -7.6 ± 12.0 LL01571FC6 -8 -18 1 0.3 ± 1.3 0.8 ± 2.7 -11.8 ± 9.8 LL01572FC7 2 18 1 1.6 ± 2.2 2.9 ± 3.3 -3.5 ± 9.3 LL01573FC8 -8 66 1 -0.4 ± 0.2 3.9 ± 3.6 -1.5 ± 11.1 LL01574FC9 -3 42 1 -0.4 ± 0.2 0.3 ± 2.5 -10.2 ± 12.2 LL01575FC10 -3 -42 1 -0.4 ± 0.2 1.8 ± 3.0 -10.6 ± 12.7 LL01576FC11 -3 -83 1 -0.4 ± 0.2 0.3 ± 2.5 -2.1 ± 11.0 LL01577FD1 7 95 0 -0.4 ± 0.2 1.8 ± 3.0 -15.5 ± 9.7 LL01578FD2 7 -62 0 1.0 ± 1.8 2.3 ± 3.2 -5.5 ± 11.0 LL01579FD3 -3 2 0 1.0 ± 1.8 -0.2 ± 2.3 -9.1 ± 11.8 LL01580FD4 2 22 1 -0A4 ± 0.2 0.8 ± 2.7 -15.9 ± 10.5 LL01581FD5 17 -6 1 -0.4 ± 0.2 1.8 ± 3.0 -9.9 ± 10.1 LL01582FD6 -3 143 0 -0.4 ± 0.2 1.3 ± 2.8 -13.6 ± 11.3 LL01583FD7 -8 147 1 0.3 ± 1.3 -0.7 ± 2.0 -10.6 ± 11.6 LL01584FD8 -13 103 1 1.0 ± 1.7 5.0 ± 3.5 -10.9 ± 10.3 LL01585FD9 7 -30 1 1.0 ± 1.7 2.0 ± 2.7 -6.9 ± 9.7 LL01586FD10 -8 75 1 2.2 ± 2.3 1.1 ± 2.4 -16.8 ± 10.0 LL01587FD11 -3 6 1 1.0 ± 1.7 -0.2 ± 1.9 -4.7 ± 12.4 LL01588QA NIA N/A N/A 1.0 ± 1.7 3.3 ± 3.1 1.8 ± 7.0 LL01589WA1A 2 -288 0 -0.2 ± 0.2 -1.5 ± 1.3 -3.3 ± 7.5 LL01590WA2A -13 -207 0 0.4 ± 1.2 0.7 ± 2.3 12.4 ± 9.4 LL01591WA3A -13 -211 0 -0.2 ± 0.2 -0.6 ± 1.7 -3.3 ± 7.5 LL01592WA4A -13 -264 0 0.4 ± 1.2 0.7 ± 2.3 -3.7 ± 6.4 LL01593WA5A -13 -155 1 1.0 ± 1.7 -0.2 ± 1.9 -2.5 ± 7.8 LL01594

C-5-1

Page 30: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-out andTermination Surv, Camrnj"lmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 3Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cmA2 dprn/100lc^2 uR/hr dpm/100cmA2 +1-2 sigma Number

(Bkgd =>) 5 0.0 to 0.33 1.07 to 1.18 7.86 to 7.9

(MDA =>) 52 284 - 2.29 * 2.5 * 27.7 *

WA6A -8 -252 1 -0.2 + 0.2 2.4 + 2.8 -4.5 1 7.0 LL01595WA7A -13 -216 1 -0.2 ± 0.2 2.4 ± 2.8 -2.0 ± 7.7 LL01596WA8A -3 -107 1 1.0 ± 1.7 -0.2 + 1.9 -3.7 + 7.3 LL01597

WA9A -8 -147 1 -0.2 + 0.2 -0.2 ± 1.9 -8.2 ± 7.3 LL01598WAlDA -3 -107 1 0.4 + 1.2 -1.0 ± 1.5 -3.4 ± 7.7 LL01599WA11A -13 -232 1 1.6 ± 2.0 1.1 ± 2.4 -2.0 ± 7.7 LL01600

WAIB -8 -248 0 -0.2 ± 0.2 -0.6 ± 1.7 -3.2 ± 7.4 LL01601WA2B -8 -203 0 0.4 ± 1.2 -1.0 ± 1.5 -5.2 ± 8.1 LL01602

WA3B -8 -344 0 -0.2 ± 0.2 0.7 ± 2.3 -3.9 ± 7.6 LL01603

WA4B -13 -244 1 -0.2 ± 0.2 -0.2 ± 1.9 -3.4 ± 7.7 LL01604

WA5B -3 -191 0 0.4 ± 1.2 2.8 ± 2.9 1.2 ± 7.7 LL01605WA6B -8 -123 0 -0.2 ± 0.2 -2.3 ± 0.4 -9.3 ± 8.8 LL01606WA7B 2 -199 0 -0.2 ± 0.2 0.3 ± 2.1 -7.7 ± 8.5 LL01607

WA8B 7 -95 0 -0.2 ± 0.2 -0.2 ± 1.9 -4.8 ± 7.5 LL01608WA9B -13 -288 0 -0.2 ± 0.2 -0.6 ± 1.7 -1.6 ± 8.1 LL01609

WA10B -13 -163 1 -0.2 ± 0.2 2.0 ± 2.7 -6.7 ± 8.6 LL01610

WAl1B -3 -312 1 -0.2 ± 0.2 -0.2 ± 1.9 -5.6 ± 7.3 LL01611WAIC -13 '-248 0 -0.2 ± 0.2 1.5 ± 2.6 -1.1 ± 7.8 LL01612

WA2C -13 -207 0 0.4 ± 1.2 -1.0 ± 1.5 -3.6 ± 8.1 LL01613WA3C -13 -195 1 -0.2 ± 0.2 0.3 ± 2.1 -2.7 ± 8.4 LL01614

WA4C -3 -256 1 0.4 ± 1.2 -0.6 ± 1.7 2.4 ± 8.9 LL01615

WA5C -3 -211 1 -0.2 ± 0.2 -1.0 ± 1.5 -6.5 ± 7.1 LL01616WA6C -8 -211 1 -0.2 ± 0.2 0.3 ± 2.1 -3.0 ± 7.9 LL01617

WA7C 2 -284 0 -0.2 ± 0.2 -0.6 ± 1.7 -2.0 ± 7.7 LL01618

WA8C 2 -183 1 -0.2 ± 0.2 -1.5 ± 1.3 -5.1 ± 7.3 LL01619WA9C -8 -272 0 -0.2 ±" 0.2 0.3 ± 2.1 -3.7 ± 7.3 LL01620WA10C... 2 -304 0 -0.2 ± 0.2 0.3 ± 2.1 -7.4 ± 7.0 LL01621WA11C -8 -304 0 -0.2 ±0.2 0.3 ± 2.1 -5.7 ± 7.4 LL01622

WB1A -8 -79 0 -0.2 ± 0.2 .0.6 ± 1.7 -9.3 ± 9.4 LL01623WB2A -8 -123 0 -0.2 ± 0.2 0.3 ± 2.1 -2.6 ± 8.2 LL01624

WB3A -13 -187 1 -0.2 ± 0.2 -0.6 ± 1.7 -7.6 * 7.2 LL01625WVB4A 7 -211 1 -0.2 ± 0.2 -0.2 ± 1.9 -2.4 ± 7.6 LL01626

WB1B -3 -256 0 -0.2 ± 0.2 1.1 ± 2.4 -3.8 ± 7.5 LL01627WB2B 2 -163 1 3.9 * 3.1 5.8 ± 3.7 -10.2 ± 8.5 LL01628WB3B -3 -127 1 1.0 ± 1.7 -0.2 ± 1.9 -4.9 ± 8.6 LL01629WB4B 2 -91 2 0.4 ± 1.2 0.3 ± 2.1 -4.4 ± 8.7 LL01630

VBIC 7 -167 1 0.4 ± 1.2 0.7 ± 2.3 -4.3 ± 8.4 LL01631WB2C 2 -38 1 2.8 ± 2.6 11.0 ± 4.7 -0.2 ± 8.7 LL01632

WB3C 7 -139 1 -0.2 ± 0.2 3.3 ± 3.1 -7.3 ± 8.1 LL01633

WVB4C -8 -91 0 0.4 ± 1.2 -0.6 ± 1.7 -9.2 ± 7.2 LL01634

WC1A -13 -211 1 -0.2 ± 0.2 -0.6 ± 1.7 11.9 ± 9.9 LL01635WC2A -8 -135 1 -0.2 ± 0.2 -0.2 ± 1.9 -2.1 ± 8.2 LL01636

WC3A -13 -171 1 -0.2 ± 0.2 0.7 ± 2.3 -2.1 ± 8.1 LL01637WC4A -3 -119 1 -0.2 ± 0.2 1.1 ± 2.4 -3.0 ± 7.9 LL01638

WC5A -8 -167 1 -0.2 ± 0.2 1.5 ± 2.6 -6.0 ± 7.8 LL01639

WC6A -8 -71 1 -0.2 ± 0.2 -1.0 ± 1.5 -4.7 ± 7.4 LL01640

WC7A -3 -79 0 0.4 ± 1.2 0.3 ± 2.1 -3.3 ± 7.5 LL01641

WC8A -3 -163 0 1.6 ± 2.0 -1.0 ± 1.5 -6.5 ± 7.1 LL01642

WC9A -13 -79 0 -0.2 ± 0.2 1.5 ± 2.6 -4.2 ± 7.4 LL01643WC10A -13 -216 0 -0.2 ± 0.2 -0.6 ± 1.7 9.9 ± 9.3 LL01644

C-5-2

Page 31: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 21MH-4939-R-97, Facility Close-oi-r-and_ Termination Surv, Cam'. ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 3Location Monitoring Wipe Test. Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cmA2 dpr/l 00cmA2 uR/hr dpm/100cmA2 +1- 2 sigma Number

(Bkgd =>) 5 0.0 to 0.33 1.07 to 1.18 7.86 to 7.9(MDA =>) 52 284 - 2.29 " 2.5 27.7 "WC11A -8 -216 0 0.4 ± 1.2 -0.6 ± 1.7 -4.7 ± 7.4 LL01645WC1B -8 -83 1 1.0 ± 1.7 -0.2 ± 1.9 -6.0 ± 7.8 LL01646WC2B -3 -123 1 -0.2 ± 0.2 0.7 ± 2.3 -3.2 ± 8.6 LL01647WC3B 2 -111 0 -0.2 ± 0.2 1.5 ± - 2.6 -3.1 ± 8.1 LL01648WC4B -8 -75 0 0.4 ± 1.2 -1.5 ± 1.3 -7.0 ± 7.7 LL01649WC5B -13 -191 1 0.4 ± 1.2 -0.2 ± 1.9 -6.7 ± 7.3 LL01650WC6B -13 -42 1 1.0 ± 1.7 0.3 ± 2.1 . -2.0 ± 7.9 LL01651WC7B -13 -2 0 -0.2 + 0.2 -0.2 ± 1.9 -1.5 ± 7.9 LL01652WC8B -8 -91 0 0.4 ± 1.2 2.0 ± 2.7 -3.2 ± 7.4 LL01653WC9B -3 -147 1 -0.2 ± 0.2 -1.5 ± 1.3 -4.0 ± 7.8 LL01654WC10B -8 -119 1 -0.2 ± 0.2 1.5 ± 2.6 -4.9 ± 7.7 LL01655,WC11B -3 -95 1 -0.2 ± 0.2 -1.5 ± 1.3 -7.7 ± 7.8 LL01656WC1C 2 -139 1 -0.2 ± 0.2 1.1 ± 2.4 -2.7 + 8.4 LL01657WC2C -8 -203 0 -0.2 ± 0.2 -0.2 ± 1.9 -8.0 ± 7.6 LL01658WC3C -8 -187 1 0.4 ± 1.2 0.7 ± 2.3 -3.5 ± 7.9 LL01659WC4C -8 -163 1 -0.2 ± 0.2 0.3 ± 2.1 -4.0 ± 7.8 LL01660WC5C 2 -224 1 0.4 ± 1.2 1.1 ± 2.4 -7.3" ±, 7.4 LL01661WC6C -3 -91. 1 -0.2 ± 0.2 0.7 ± 2.3 -4.1 ± 8.0 LL01662WC7C -8 -232 1 -0.2 ± 0.2 2.0 ± 2.7 -5.9 ± 7.6 LL01663WC8C -13 -99 1 -0.2 ± 0.2 0.7 ± 2.3 -6.1 ± 7.2 LL01664WC9C 2 -143 0 -0.2 ± 0.2 0.7 ± 2.3 -4.1 ± 8.0 LL01665WC10C -8 -143 1 -0.2 ± 0.2 -1.9 ± 0.9 -0.1 ± 7.9 LL01666WC11C -13 -244 0 0.4 ± 1.2 0.3 ± 2.1 -7.6 ± 7.2 LL01667WD1A 7 -377 0 -0.2 ± 0.2 -0.6 ± 1.7 -9.2 ± 7.2 LL01668WD2A -3 -276 -1 -0.2 ± 0.2 2.8 ± 2.9 -20.3 ± 12.7 LL01669WD3A -3 -284 0 0.4 ± 1.2 -0.6 ± 1.7 -9.0 ± 9.2 LL01670WD4A -13 -232 0 -0.2 ± 0.2 0.3 ± 2.1 -8.9 ± 9.8 LL01671WD1B -8 -340 -1 -0.2 ± 0.2 0.7 ± 2.3 -3.2 ± 8.6 LL01672WD2B -13 -232 -1 0.4 ± 1.2 -0.2 ± 1.9 -15.0 + 11.1 LL01673WD3B -13 -292 0 -0.2 ± 0.2 -0.2 ± 1.9 -4.9 ± 9.7 LL01674WD4B -8 -344 -1 -0.2 ± 0.2 -0.6 ± 1.7 -9.0 ± 9.2 LL01675WDIC -8 -159 0 -0.2 ± 0.2 -0.6 ± 1.7 13.5 ± 9.9 LL01676WD2C -3 -232 -1 -0.2 ± 0.2 2.4 ± 2.8 -6.7 ± 9.5 LL01677WVD3C -13 -252 0 0.4 ± 1.2 0.7 ± 2.3 -6.3 ± 8.9 LL01678WVD4C -3 -244 -1 -0.1 ± 0.1 0.6 ± 2.9 -5.4 ± 10.6 LL01679QA N/A NIA N/A -0.1 ± 0.1 -1.1 ± 2.3 -5.7 ± 6.3 LL01680

Indicates the highest MDA for this survey unit. The Alpha MDA ranged from 1.87 to 2.29 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.9 to 2.5 dpm

Indicates the highest MDA for this survey unit. The H-3B MDA ranged from 12.49 to 27.7 dpm

C-5-3

Page 32: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 1072Room 4

W*Ic I I I I I I I -A

I Isia I I I I I I I I I IVIA

wi77 woACz 4AL2vo LJ2F

1AWA III11II AI

(FA F A

Žz iID~WCP ~P

_11 ± 1A- -

FVTVwe1A] Ijwa I4B_!_ LW CJ

14

A

BUILDING 1072, ROOM 4. CAMP KILMER, NEW JERSEY DATE- 20 OCT 97

DRAWN: MSD

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCA:;. NTSUNITED STATES ARMY MEDICAL DEPARTMENT T:

C-6

Page 33: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. ; IH-4939-R-97, Facility Close-oi'--ndTermination Surv, Camp *.,ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 4Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units =>) dpm/lOOcmA2 dpmr1OOcmA2 uR/hr dpm/1OOcrnA2 +1-2 sigma Number

(Bkgd =>) 5 0.0 to 0.33 0.86 to 1.18 7.86 to 7.9(MDA =>) 52 284 - 2.29 * 2.5 " 21.97FA1 7 -244 -1 0.7 ± 1.5 0.6 ± 2.9 -9.2 ± 10.9 LL01681FA2 -3 -240 0 -0.1 ± 0.1 -1.6 ± 2.0 -12.9 ± 8.1 LL01682FA3 -3 -296 0 -0.1 ± 0.1 1.2 ± 3.1 -8.6 ± 8.1 LL01683FA4 -13 -252 0 -0.1 ± 0.1 1.7 ± 3.3 -8.1 ± 8.2 LL01684FA5 -13 -220 0 -0.1 ± 0.1 0.1 ± 2.7 -9.9 ± 7.3 LL01685FA6 12 -211 0 -0.1 ± 0.1 -1.1 ± 2.3 -14.1 ± 8.0 LL01686FA7 2 -248 0 -0.1 ± 0.1 0.6 ± 2.9 -4.1 ± 8.0 LL01687FA8 2 -199 1 -0.1 ± 0.1 -1.1 ± 2.3 -1.6 ± 8.1 LL01688FA9 2 -240 0 -0.1 ± 0.1 3.4 ± 3.8 -6.7 ± 7.9 LL01689FA10 -8 -171 0 -0.1 ± 0.1 2.3 ± 3.5 -6.5 ± 8.4 LL01690FAll -13 -199 0 -0.1 ± 0.1 0.6 ± 2.9 0.3 ± 8.1 LL01691FB1 23 -236 -1 -0.1 ± 0.1 0.6 ± 2.9 32.9 ± 15.2 LL01692FB2 -3 -203 0 -0.1 ± 0.1 -1.6 ± 2.0 -11.7 ± 7.7 LL01693FB3 -13 -336 0 -0.1 ± 0.1 -1.6 ± 2.0 -0.7 7 9.1 LL01694FB4 23 - -324 0 0.7 ± 1.5 -1.1 ± 2.3 -10.2 ± 7.9 LL01695FB5 7 -256 0 -0.1 ± 0.1 -0.5 ± 2.5 -6.2 ± 8.0 LL01696FB6 -8 -151 0. 0.7 ±" 1.5 0.1 ± 2.7 .- 4.3 ± 8.4 LL01697F87 -3 -203 0 1.5 ± 2.2 0.1 t 2.7 -2.7 ± 8.4 LL01698FB8 -3 -316 0 -0.1 ± 0.1 0.1 ± 2.7 -4.1 ± 8.0 LL01699FB9 -13 -199 0 0.7 ± 1.5 -2.2 ± 1.6 -3.7 ± 8.3 LL01700FB10 -8 -191 0 0.7 ± 1.5 0.6 "± 2.9 -6.8 ± 8.4 LL01701FB11 12 -260 0 1.5 ± 2.2 -1.1 ± 2.3 -5.7 ± 9.0 LL01702FC1 7 -167 -1 -0.1 ± 0.1 1.2 - 3.1 -8.7 ± 9.5 LL01703FC2 -8 -324 0 0.7 ± 1.5 -1.1 ± 2.3 -4.9 ± 9.7 LL01704FC3 -3 -244 0 0.7 ±. 1.5 0.6 ± 2.9 -3.2 ± 8.6 LL01705FC4 -3 -264 -1. -0.1 ± 0.1 -1.1 ± 2.3 -1.7 ± 8.5 LL01706FC5 -13 -228 -1 0.7 ± 1.5 -0.5 ± 2.5 -8.9 ± 7.9 LL01707FC6 12 -224 0 -0.1 ± 0.1 1.7 ± 3.3 -3.7 ± 8.3 LL01708FC7 -8 -216 0 -0.1 ± 0.1 0.1 ± 2.7 -1.7 ± 8.5 LL01709FC8 2 -107 0 -0.1 + 0.1 -1.6 ± 2.0 -6.0 ± 7.8 LL01710FC9 -13 -203 0 -0.1 ± 0.1 0.1 + 2.7 2.9 ± 9.2 LL01711FC10 -3 -203 0 -0.1 ± 0.1 -0.5 ± 2.5 -2.9 ± 9.1 LL01712FC11 2 -264 0 -0.1 ± 0.1 1.7 ± 3.3 -2.7 ± 8.6 LL01713FD1 2 -365 0 -0.1 ± 0.1 3.4 ± 3.8 -6.3 ± 8.2 LL01714FD2 7 -252 0 0.7 ± 1.5 -0.5 ± 2.5 -8.1 ± 8.2 LL01715FD3 -3 -272 0 -0.1 ± 0.1 1.7 ± 3.3 -5.7 ± 8.0 LL01716FD4 -8 -280 0 -0.1 ± 0.1 -3.3 ± 0.6 -4.4 ± 7.8 LL01717FD5 12 -171 0 -0.1 ± 0.1 1.7 ± 3.3 -0.2 ± 8.5 LL01718FD6 2 -268 0 0.7 ± 1.5 -0.5 ± 2.5 -4.1 ± 8.0 LL01719FD7 -3 -248 0 -0.1 ± 0.1 -0.5 ± 2.5 -6.3 ± 8.2 LL01720FD8 23 -252 0 -0.1 ± 0.1 1.2 ± 3.1 -7.0 ± 7.7 LL01721FD9 -3 -199 0 0.7 ± 1.5 0.6 ± 2.9 -6.7 ± 7.3 LL01722FD10 2 -268 0 -0.1 ± 0.1 -1.1 ± 2.3 -8.7 ± 7.3 LL01723FD11 -3 -203 0 -0.1 ± 0.1 2.0 ± 2.8 -5.4 ± 7.7 LL01724SHELF FA9 2 -401 -1 -0.1 + 0.1 2.2 ± 2.9 -0.6 ± 8.2 LL01725SHELF FA1 -3 -373 0 -0.1 ± 0.1 0.2 ± 2.0 -2.5 ± 7.8 LL01726WAIA -3 -421 -1 1.1 ± 1.7 1.5 ± 2.7 -2.4 ± 7.5 LL01727WA2A 2 -207 -1 -0.1 ± 0.1 0.3 ± 2.2 -5.5 ± 7.1 LL01728WA3A 2 -389 -1 -0.1 ± 0.1 1.6 + 2.5 -1.5 ± 7.6 LL01729WA4A 2 -276 0 -0.1 ± 0.1 0.2 ± 2.2 -4.0 ± 7.1 LL01730

C-6-1

Page 34: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-oul--andTermination Surv, Camp" -)lmer,'NJ, 1 Jul - 20 Dec 97

* Camp Kilmer, BUILDING 1072 ROOM 4

Location Monitoring Wipe TestCode Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm,1OOcmA2 dpm/100cmA2 uR/hr dprn/1OOcmA2 +1-2 sigma Number

(Bkgd =>) 5 0.0 to 0.33 0.86 to 1.18 7.86 to 7.9

(MDA=>) 52 284 - 2.29 2.5 " 21.97

WA5A 12 -401 0 0.5 ± 1.2 1.3 ± 2.6 -2.7 ± 7.3 LL01731

WA6A 2 -300 -1 -0.1 ± 0.1 -0.2 ± 1.8 -4.6 ± 7.2 LL01732

WA7A 7 -361 -1 -0.1 ± 0.1 -0.7 ± 1.8 -5.8 ± 6.9 LL01733

WA8A -13 -348 -1 -0.1 ± 0.1 -1.0 ± 1.6 -1.9 ± 7.4 LL01734

WA9A -3 -324 0 -0.1 ± 0.1 0.7 ± 2.2 2.5 ± 8.0 LL01735

WA10A -8 -421 0 -0.1 ± 0.1 -0.3 ± 2.0 -5.8 ± 6.9 LL01736

WA11A .2 -365 0 1.1 ± 1.7 -0.6 ± 1.8 -2.7 ± 7.3 LL01737

WAIB -13 -425 0 -0.1 ± 0.1 -0.7 ± 1.6 -1.1 ± 7.8 LL01738

WA2B -8 -332 0 -0.1 ± 0.1 0.6 ± 2.4 1.2 ± 7.9 LL01739

WA3B 7 -405 0 1.7 ± 2.0 -1.0 ± 1.6 -0.6 ± 7.5 LL01740WA4B -13 -348 0 -0.1 ± 0.1 0.7 ± 2.2 -2.9 ± 7.8 LL01741

WA5B -8 -429 0 -0.1 ± 0.1 -0.7 ± 1.8 -1.4 ± 7.4 LL01742

WA6B -13 -357 0 0.5 ± 1.2 0.8 ± 2.4 -5.0 ± 7.2 LL01743

WA7B -3 -352 -1 0.5 ± 1.2 1.6 ± 2.5 -5.5 ± 7.1 LL01744

WA8B -8 -340 0 -0.1 ± 0.1 -0.3 ± 2.0 -5.8 ± 6.9 LL01745

WA9B -13 -328 0 0.5 ± 1.2 0.3 ± 2.2 -1.9 ± 7.5 LL01746

WA10B -13 -437 0 -0.1 ± 0.1 2.0 ± 2.6 -5.0 ± 7.2 LL01747

WAliB -3 -421- 0 0.5 ± 1.2 1.1 ± 2.6 -5.3 ± 7.5 LL01748

WAIC 12 -377 0 0.5 ± 1.2 -1.0 ± 1.6 -4.5 ± 7.0 LL01749

WA2C -3 -373 0 0.5 ± 1.2 -1.1 ± 1.3 -3.7 ± 7.3 LL01750

WA3C -13 -397 0 -0.1 ± 0.1 -0.7 ± 1.8 -4.9 ± 7.0 LL01751

WA4C -8 -381 -1 -0.1 ± 0.1 2.6 ± 3.0 -2.3 ± 7.3 LL01752

WA5C -8 -328 -1 -0.1 ± 0.1 -1.1 ± 1.3 -2.7 ± 7.3 LL01753

WA6C 2 -433 0 0.5 ± 1.2 2.0 ± 2.8 -3.7 ± 7.3 LL01754

WA7C -8 -389 0 -0.1 ± 0.1 . -1.0 ± 1.6 -1.9 ± 7.5 LL01755

WA8C -3 -385 0 -0.1 ± 0.1 -2.0 ± 0.4 -1.5 ± 7.6 LL01756

WA9C -3 -397 0 -0.1 ± 0.1 2.0 .± 2.8 -5.0 ± 7.2.. LL01757

WA10C -13 -433 0 -0.1 ± 0.1 0.8 ± 2.4 -5.8 ± 6.9 LL01758WA11C -3 -465 0 -0.1 ± 0.1 1.1 * 2.3 -6.4 ± 7.0 LL01759

WBIA 28 -401 0 -0.1 ± 0.1 0.2 ± 2.2 -2.4 ± 7.5 LL01760

WB2A 2 -409 0 -0.1 ± 0.1 1.7 ± 2.7 -5.0 * 7.2 LL01761

WB3A 2 -393 0 -0.1 ± 0.1 -0.7 ± 1.6 -4.9 ± 7.0 LL01762

WB4A -8 -429 0 -0.1 ± 0.1 -1.2 ± 1.6 -6.1 ± 7.2 LL01763

WB1B 7 -473 0 -0.1 ± 0.1 -0.1 ± 2.0 -4.3 ± 6.8 LL01764

WB2B -8 -485 0 -0.1 ± 0.1 1.1 ± 2.3 -0.6 ± 7.7 LL01765

WB3B 2 -336 0 -0.1 ± 0.1 -1.2 ± 1.6 -2.4 ± 7.6 LL01766

WB4B -8 -377 1 0.5 ± 1.2 3.5 ± 3.2 -2.9 ± 7.6 LL01767

WBIC -3 -389 1 -0.1 ± 0.1 0.2 ± 2.0 -1.0 ± 7.6 LL01768

WB2C -13 -441 0 -0.1 ± 0.1 0.6 ± 2.4 -5.1 ± 7.3 LL01769

WB3C 2 -332 -1 0.5 ± 1.2 -0.1 ± 2.0 -3.9 ± 7.6 LL01770

WB4C 2 -421 0 -0.1 ± 0.1 -0.7 ± 1.6 -6.7 ± 6.8 LL01771WC1A 2 -449 0 0.5 ± 1.2 -0.3 ± 2.0 -6.1 ± 6.7 LL01772

WC2A -3 -409 0 -0.1 ± 0.1 0.8 ± 2.4 -8.8 ± 6.9 LL01773

WC3A -13 -393 0 -0.1 ± 0.1 -1.6 ± 1.0 -8.6 ± 6.7 LL01774

WC4A 2 -308 0 -0.1 ± 0.1 -2.1 ±. 1.0 0.8 ± 7.8 LL01 775

WC5A -13 -393 0 -0.1 ± 0.1 1.3 ± 2.6 -4.7 ± 7.4 LL01776

WC6A -13 -377 0 0.5 ± 1.2 -0.7 ± 1.6 -2.3 ± 7.3 LL01777WC7A 2 -373 0 0.5 ± 1.2 0.2 ± 2.2 -1.0 ± 7.6 LL01778

WC8A -3 -409 0 -0.1 ± 0.1 -0.6 ± 1.8 -4.6 ± 7.2 LL01779

WC9A 7 -324 0 -0.1 ± 0.1 0.2 ± 2.0 -6.4 ± 7.0 LL01780

C-6-2

Page 35: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 7-- 1H-4939-R-97, Facility Close-o andTermination Surv, Cam'. .ilmer, NJ, 1 Jul - 20 Dec 97

Camn Kllmer BUILDING 1072 ROOM 4Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cm^2 dpm/100cmA2 uR/hr dpm/100cm^2 +/-2 sigma Number

(Bkgd =>) 5 0.0 to 0.33 0.86 to 1.18 7.86 to 7.9(MDA=>) 52 284 - 2.29 " 2.5 21.97 *WC10A 7 -473 0 0.5 ± 1.2 -0.3 ± 2.0 -4.0 ± 7.1 LL01781WC11A 12 -377 0 -0.1 ± 0.1 -1.0 ± 1.6 -4.1 ± 7.3 LL01782WC1B -8 -405 0 0.5 ± 1.2 0.2 ± 2.0 -7.1 ± 6.7 LL01783WC2B 17 -409 0. -0.1 ± 0.1 0.2 ± 2.2 -4.9 ± 7.0 LL01784WC3B -3 -365 0 0.5 ± 1.2 -0.1 ± 2.0 -6.7 ± 6.8 LL01785WC4B 2 -365 0 0.5 ± 1.2 0.7 ± 2.2 -5.9 ± 7.0 LL01786WC5B -13 -425 0 -0.1 ± 0.1 2.0 ± 2.8 -2.5 ± 7.8 LL01787WC6B -8 -437 0 -0.1 ± 0.1 -1.5 ± 1.3 -4.0 ± 7.1 LL01788WC7B -3 -425 -1 -0.1 ± 0.1 -0.7 ± 1.6 -6.4 ± 7.0 LL01789WC8B -13 -348 -1 -0.1 ± 0.1 -1.2 ± 1.6 -6.8 ± 6.9 LL01790WC9B -8 -389 -1 0.5 ± 1.2 1.3 ± 2.6 0.3 ± 7.6 LL01791WC10B -8 -377 0 -0.1 ± 0.1 -0.2 ± 1.8 -1.9 ± 7.5 LL01792WC11B 2 -397 0 0.5 ± 1.2 1.1 ± 2.6 -4.7 ± 7.4 LL01793WC1C -3 -469 0 0.5 ± 1.2 1.3 ± 2.6 -3.2 ± 7.4 LL01794WC2C -8 -397 0 0.5 ± 1.2 0.2 ± 2.0 0.3 ± 7.8 LL01795WC3C -3 -361 0 -0.1 ± 0.1 2.4 ± 3.0 -6.1 ± 7.2 LL01796WC4C -13 -405 -1 0.5 ± 1.2 -1.0 ± 1.6 0.8 ± 7.8 LL01797WC5C 7 -421- 0 -0.1 ± 0.1 1.6 ± 2.5 -4.6 ± 7.2 LL01798WC6C -8 -377 0 -0.1 ± 0.1 2.0 ± 2.8 -4.7 ± 7.4 LL01799WC7C -3 -409 0 -0.1 ± 0.1 -1.0 ± 1.6 -7.5 ± 6.7 LL01800WC8C -8 -421 -1 -0.1 ± 0.1 -0.2 ± 1.8 -5.9 ± 7.0 LL01801WC9C -8 -328 0 -0.1 ± 0.1 -0.7 ± 1.8 0.3 ± 7.8 LL01802WC10C -3 -393 0 0.5 ± 1.2 -0.6 ± 1.8 -5.5 ± 7.1 LL01803WC11C -8 -348 0 -0.1 ± 0.1 -0.2 ± 1.8 -6.5 ± 7.1 LL01804WD1A -8 -401 0 -0.1 ± 0.1 -0.3 ± 2.0 -4.6 ± 7.2 LL01805WD2A -3 -409 0 0.5 ± 1.2 -0.6 t 1.8 -4.0 ± 7.1 LL01806WD3A -3 -352 0 0.5 ± 1.2 1.1 ± 2.3 -8.3 ± 6.9 LL01807WD4A -13 -365 0 -0.1 ± 0.1 -1.6 ± 1.3 -1.1 ± 7.8 LL01808WD1B -13 -348 0 0.5 ± 1.2 1.3 ± 2.6 -2.5 ± 7.8 LL01809WD2B -13 -264 0 -0.1 ± 0.1 -0.2 ± 1.8 -7.0 ± 7.1 LL01810WD3B 2 -377 0 -0.1 ± 0.1 -1.2 ± 1.6 -1.9 ± 7.5 LL01811WD4B 7 -348 0 0.5 ± 1.2 -0.1 ± 2.0 -1.5 ± 7.6 LL01812WD1C -13 -425 0 -0.1 ± 0.1 2.9 ± 2.9 -0.1 ± 7.5 LL01813WD2C -8 -328 0 0.5 ± 1.2 -0.3 ± 2.0 2.0 ± 7.8 LL01814WD3C -13 -328 0 -0.1 ± 0.1 1.3 ± 2.6 -1.0 ± 7.6 LL01815WD4C -13 -429 0 -0.1 ± 0.1 0.2 ± 2.0 -4.1 ± 7.3 LL01816QA N/A N/A N/A -0.1 ± 0.1 0.8 ± 2.2 6.9 ± 7.5 LL01817

Indicates the highest MDA for this survey unit. The Alpha MDA ranged from 1.76 to 2.29 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.9 to 2.5 dpm

Indicates the highest MDA for this survey unit. The H-3 MDA ranged from 12.49 to 21.97 dpm

C-6-3

Page 36: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facillity Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

C-7

Page 37: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. --- ,MH-4939-R-97, Facility Close-o,-1-ýandTermination Surv, Cam, .3ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 5

Location Monitoring Wipe TestCode Alpha Beta Gamma Alpha Beta A LS Wipe

(Units =>) dpmrlO00cA2 dpmr/100cmA2 uRlhr dpm/100cmA12 +-2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.79 to 1.25 7.86 to 7.9

(MDA=>) 52 227 - 2.14 " 2.23 - 79.65

FA1 28 -106 -1 -0.1 ± 0.1 0.2 ± 2.0 -0.7 ± 9.9 LL01818FA2 -3 -68 -1 -0.1 ± 0.1 -0.3 ± 2.0 -9.0 ± 9.2 LL01819FA3 -3 16 -1 -0.1 ± 0.1 0.3 ± 2.2 -10.7 ± 13.9 LL01820FA4 -3 -9 0 -0.1 ± 0.1 0.7 ± 2.2 -4.9 ± 11.0 LL01821FA5 -13 -55 0 -0.1 ± 0.1 -1.6 ± 1.3 -2.9 ± 9.3 LL01822FA6 -8 -136 0 0.5 ± 1.2 2.2 ± 2.9 -8.5 ± 8.7 LL01823FA7 -8 -98 -1 -0.1 ± 0.1 -1.1 ± 1.3 -10.8 ± 9.6 LL01824FA8 7 -34 -1 0.5 ± 1.2 -1.2 ± 1.6 -7.4 ± 8.8 LL01825FA9 -3 -106 -1 -0.1 ± 0.1 -0.6 ± 1.8 -10.8 ± 9.6 LL01826FA10 -8 -51 -1 -0.1 ± 0.1 0.2 ± 2.0 -12.5 ± 11.9 LL01827FB1 2 97 0 -0.1 ± 0.1 -1.6 ± 1.3 -15.9 ± 10.5 LL01828FB2 12 143 0 -0.1 ± 0.1 0.3 ± 2.2 -6.2 ± 9.8 LL01829FB3 2 194 0 0.5 ± 1.2 -0.7 ± 1.6 -8.2 ± 10.6 LL01830FB4 -8 122 -1 0.5 ± 1.2 0.2 ± 2.2 -12.2 ± 12.5 LL01831FB5 -3 122 0 -0.1 ± 0.1 0.8 ± 2.4 -12.2 ± 10.2 LL01832FB6 7 177 0 -0.1 ± 0.1 0.2 ± 2.0 -5.5 ± 11.0 LL01833FB7 17 122 0 -0.1 ± 0.1 -0.7 ± 1.8 -12.5 ± 11.9 LL01834FB8 23 164. -1 0.5 ± 1.2 0.3 ± 2.2 -14.4 ± 12.8 LL01835FB9 12 46 -1 0.5 ± 1.2 0.7 ± 2.2 -9.4 ± 13.4 LL01836FB1O 7 97 0 -0.1 ± 0.1 -0.3 ± 2.0 -3.4 ± 10.8 LL01837FB11 -8 97 0 -0.1 ± 0.1 1.3 ± 2.6 -16.8 ± 18.5 LL01838FB12 -3 147 0 0.5 ± 1.2 0.2 ± 2.0 -16.9 ± 29.7 LL01839F13 -8 122 0 -0.1 ± 0.1 1.1 ± 2.6 -18.4 ± 14.4 LL01840FB14 -8 236 0 -0.1 ± 0.1 -1.0 ± 1.6 -5.5 ± 11.0 LL01841FB15 -8 -13 0 0.5 ± 1.2 0.2 ± 2.0 -2.1 ± 11.0 LL01842FC1 7 257 0 -0.1 ± 0.1 -0.3 ± 2.0 -0.2 ± 12.0 LL01843FC2 -8 88 0 -0.1 ± 0.1 -0.6 ± 1.8 -11.4 * 9.5 LL01844FC3 -3 114 0 1.2 ± 1.7 1.1 ± 2.3 -16.4 ± 11.4 LL01845FC4 -3 147 0 -0.1 ± 0.1 2.0 ± 2.8 -10.3 ± 13.3 LL01846

FC5 -8 164 0 -0.1 ± 0.1 2.2 ± 2.9 -16.5 ± 14.6 LL01847FC6 -3 126 0 -0.1 ± 0.1 2.0 ± 2.6 -22.2 ± 13.9 LL01848FC7 2 80, 0 0.5 ± 1.2 0.2 ± 2.2 -10.2 ± 11.2 LL01849

FC8 -3 194 0 -0.1 ± 0.1 1.3 ± 2.6 -7.4 ± 11.6 LL01850FC9 7 46 0 -0.1 ± 0.1 0.7 ± 2.2 -5.0 ± 11.4 LL01851FC10 -3 122 0 -0.1 ± 0.1 -1.2 ± 1.6 -1.0 ± 12.8 LL01852FC11 12 160 0 0.5 + 1.2 0.8 ± 2.4 -9.9 ± 11.7 LL01853FC12 17 -43 0 -0.1 ± 0.1 1.6 ± 2.5 30.9 ± 24.9 LL01854FC13 2 164 0 0.5 + 1.2 -0.7 ± 1.8 -13.3 ± 13.6 LL01855FC14 2 169 1 -0.1 ± 0.1 .0.3 ± 2.2 -3.3 ± 13.0 LL01856FC15 17 88 0 -0.1 ± 0.1 -0.2 ± 1.8 30.9 ± 15.9 LL01857FD1 -13 164 0 -0.1 ± 0.1 1.5 ± 2.7 -11.2 ± 10.7 LL01858FD2 -3 105 0 --0.1 ± 0.1 -0.6 ± 1.8 -7.8 ± 11.1 LL01859FD3 -8 156 0 -0.1 ± 0.1 1.6 ± 2.5 -16.9 ± 12.5 LL01860FD4 17 88 0 1.1 ± 1.7 -1.2 ± 1.6 -8.9 ± 9.8 LL01861FD5 -3 173 0 0.5 ± 1.2 0.8 ± 2.4 -10.2 ± 11.2 LL01862FD6 7 25 0 -0.1 ± 0.1 0.2 ± 2.0 -7.4 ± 13.1 LL01863FD7 12 50 0 -0.1 ± 0.1 0.6 ± 2.4 -9.9 ± 10.1 LL01864FD8 -8 109 0 -0.1 ± 0.1 1.3 ± 2.6 -6.9 ± 13.7 LL01865FD9 7 228 0 -0.1 ± 0.1 -0.7 ± 1.6 -7.2 ± 9.4 LL01866FD10 -3 139 0 -0.1 ± 0.1 2.0 ± 2.8 -12.2 ± 10.2 LL01867

C-7-1

Page 38: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-ou+--andTermination Surv, Caml'•imer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 5

Location Monitoring Wipe TestCode Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpnV100cm^2 dpm/100cmA2 uRlhr dpm/1OOcMAn2 +1-2 sigma Number

(Bkgd=>) 5 0.0 to 0.34 0.79 to 1.25 7.86 to 7.9

(MDA>) 52 227 - 2.14 " 2.23 " 79.65

FDl1 -13 224 0 -0.1 + 0.1 1.3 + 2.6 -14.0 + 16.7 LL01868FD12 -3 16 0 -0.1 E 0.1 0.2 t 2.0 6.7 t 11.6 LL01869FD13 -8 177 1 -0.1 t 0.1 1.1 t 2.6 -7.9 t 12.5 LL01870FD14 7 135 0 0.5 ± 1.2 1.7 : 2.7 1.6 t 10.7 LL01871FD15 2 46 0 -0.1 ± 0.1 0.2 t 2.0 -15.6 ± 11.5 LL01872FEl 12 190 0 -0.1 ± 0.1 -0.3 ± 2.0 -16.6 t 10.4 LL01873FE2 12 232 0 1.1 t 1.7 0.8 ± 2.4 -11.4 ± 12.6 LL01874FE3 7 122 0 0.5 1 1.2 0.7 ± 2.2 -17.8 ± 12.4 LL01875FE4 2 240 0 -0.1 ± 0.1 -1.6 ± 1.3 -10.6 ± 10.8 LL01876FE5 -3 135 0 0.5 ± 1.2 2.6 t 3.0 -11.7 ± 9.2 LL01877FE6 12 38 1 0.5 ± 1.2 0.2 ± 2.0 -8.8 t 11.4 LL01878FE7 -8 194 0 -0.1 ± 0.1 0.2 ± 2.2 -7.5 t 10.7 LL01879FEB 7 173 0 0.5 t 1.2 -0.6 ± 1.8 -11.0 ± 12.1 LL01880FE9 2 177 0 -0.1 ± 0.1 2.0 ± 2.6 -13.1 ± 10.9 LL01881FE10 2 202 0 1.1 ± 1.7 0.2 ± 2.2 2.9 ± 11.2 LL01882FEll -8 160 0 1.1 ± 1.7 -1.5 ± 1.3 -9.5 ± 11.3 LL01883FE12 -8 -26 0 -0.1 * 0.1 -0.2 ± 1.8 2.6 ± 12.7 LL01884FE13 2 -47" -1 -0.1 ± 0.1 -0.3 ± 2.0 -3.8 ± 10.1 LL01885FE14 -8 4 0 -0.1 ± 0.1 -0.1 ± 2.0 -3.2 ± 10.2 LL01886FE15 -13 -5 0 -0.1 ± 0.1 1.1 ± 2.3 -4.6 ± -10.3 LL01887FF1 2 156 0 1.1 t 1.7 -1.2 ± 1.6 -13.9 ± 14.2 LL01888FF2 -3 169 0 -0.1 ± 0.1 -0.6 ± 1.8 -11.2 ± 9.9 LL01889FF3 7 181 0 -0.1 ± 0.1 2.9 ± 2.9 -7.8 ± 11.1 LL01890FF4 12 207 0 1.1 t 1.7 2.0 ± 2.8 -15.8 ± 11.0 LL01891FF5 2 135 0 -0.1 ± 0.1 0.3 ± 2.2 -4.2 ± 11.1 LL01892FF6 -3 232 1 -0.1 ±' 0.1 0.2 ± 2.0 -6.4 ± 11.3 LL01893FF7 2 190 0 -0.1 * 0.1 -0.3 ± 2.0 -8.4 ± 14.8. LL01894FF8 7 202 0 -0.1 ± 0.1 2.2 ± 2.9 -12.6 * 17.9 LL01895FF9 -13 202 0 -0.1 ± 0.1 1.1 ± 2.3 -9.1 ± 11.8 LL01896FF10 2 274 0 -0.1 * 0.1 -0.7 ± 1.8 -2.7 ± 10.6 LL01897FF11 2 42 0 -0.1 ± 0.1 0.3 ± 2.2 -3.0 ± 15.5 LL01898FF12 -8 50 0 -0.1 ± 0.1 0.2 t 2.0 -10.2 * 12.2 LL01899FF13 2 84 0 0.5 ± 1.2 1.5 ± 2.7 -9.6 ± 9.8 LL01900FF14 7 88 0 -0.1 ± 0.1 0.8 ± 2.4 -12.3 ± 9.1 LL01901FF15 2 156 0 -0.1 ± 0.1 0.2 ± 2.0 0.5 ± 12.5 LL01902FG1 -8 156 0 - -0.1 ± 0.1 -0.3 * 2.0 -5.9 ± 11.7 LL01903FG2 -3 202 .0 0.5 ± 1.2 2.2 ± 2.9 -9.9 ± 11.7 LL01904FG3 2 126 0 1.8 ± 2.1 1.1 ± 2.3 -13.8 ± 10.8 LL01905FG4 17 105 0 0.5 ± 1.2 0.2 t 2.2 -16.6 ± 10.4 LL01906FG5 -3 232 0 -0.1 ± 0.1 -0.6 ± 1.8 -17.7 ± 13.0 LL01907FG6 -8 118 0 -0.1 * 0.1 -0.7 ± 1.6 -5.7- ± 11.3 LL01908FG7 -13 84 0 -0.1 ± 0.1 -0.3 ± 2.0 -21.3 ± 14.8 LL01909FG8 -3 186 0 -0.1 ± 0.1 -0.1 ± 2.0 -11.8 ± 12.0 LL01910FG9 -3 207 0 -0.1 ± 0.1 -0.2 t 1.8 -9.0 ± 12.9 LL01911FG10 17 211 0 -0.1 ± 0.1 -1.6 ± 1.3 -7.1 ± 11.2 LL01912FG11 -8 198 0 0.5 ± 1.2 -1.0 ± 1.6 -12.3 t 16.0 LL01913FG12 -3 88 0 0.5 ± 1.2 1.1 ± 2.3 -13.3 ± 13.6 LL01914FG13 -8 173 0 -0.1 ± 0.1 0.6 ± 2.4 -11.7 ± 15.2 LL01915FG14 2 181 -1 0.5 ± 1.2 -1.5 ± 1.3 -11.9 ± 16.9 LL01916FG15 2 50 0 -0.1 ± 0.1 1.1 ± 2.3 -2.1 ± 11.0 LL01917

C-7-2

Page 39: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. ." H-4939-R-97, Facility Close-o->and-- Termination Surv, Camp .. ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 5Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units =>) dpm/100cmA^ dpm/100cm^2 uRPhr dpm/100cmA2 +1-2 sigma Number(Bkgd =>) 5 0 00 to 0.34 0.79 to 1.25 7.86 to 7.9(MDA>) 52 227 - 2.14 * 2.23 ° 79.65 *FH1 -3 164 0 0.5 ± 1.2 0.6 ± 2.4 -12.1 ± 11.5 LL01918FH2 -3 262 0 1.7 ± 2.0 1.3 ± 2.6 -12.4 ± 11.0 LL01919FH3 -8 118 0 0.5 ± 1.2 0.7 ± 2.2 -10.2 ± 9.7 LL01920FH4 12 105 -1 -0.1 ± 0.1 0.6 ± 2.4 -11.2 ± 14.5 LL01921FIP15 -3 295 -1 0.5 ± 1.2 0.3 ± 2.2 -15.9 ± 13.2 LL01922FH16 -3 186 -1 -0.1 ± 0.1 2.0 ± 2.6 -15.5 ± 27.2 LL01923FH7 -8 177 0 2.3 ± 2.4 -0.3 ± 2.0 -5.4 ± 12.3 LL01924FH8 2 181 0 0.5 ± 1.2 3.1 ± 3.1 -19.3 ± 16.0 LL01925FH9 -3 126 0 -0.1 ± 0.1 -1.1 ± 1.3 -11.0 ± 12.1 LL01926FH10 12 126 0 -0.1 ± 0.1 -1.2 ± 1.6 -6.6 ± 11.7 LL01927FH11 -3 156 0 0.5 ± 1.2 -0.6 ± 1.8 -10.7 ± 13.9 LL01928FH12 12 126 0 2.4 ± 2.4 2.4 ± 2.8 -15.9 ± 17.5 LL01929FH13 12 88 0 -0.1 .± 0.1 -0.7 ± 1.8 -6.6 ± 17.5 LL01930FH14 2 215 0 0.5 ± 1.2 0.8 ± 2.4 -13.6 ± 15.0 LL01931FH15 -13 236 0 1.2 ± 1.7 1.1 ± 2.3 7.6 ± 24.0 LL01932F1i -3 177 0 -0.1 ± 0.1 0.6 ± 2.4 -30.5 ± 25.4 LL01933F12 12 224 0 -0.1 ± 0.1 0.3 ± 2.2 -13.6 ± 11.3 LL01934F13 -13 93' 0 0.5 ± 1.2 0.7 ± 2.2 -10.8 ± 15.3 LL01935F14 2 147 0 0.5 ± 1.2 -0.7 t 1.8 -3.7 ± 18.9 LL01936F15 -8 131 0 -0.1 ± 0.1 0.8 ± 2.4 -0.6 ± 31.5 LL01937F16 7 114 0 -0.1 *± 0.1 1.1 ± 2.3 -10.9 ± 11.1 LL01938F17 -3 194 0 0.5 ± 1.2 1.1 ± 2.6 -7.9 ± 12.5 LL01939FI8 7 143 0 -0.1 ± 0.1 -0.1 ± 2.0 -10.6 ± 12.7 LL01940F19 2 76 0 -0.1 ± 0.1 -0.7 ± 1.6 -3.9 ± 12.4 LL01941F110 2 169 0 -0.1 ±. 0.1 0.6 ± 2.4 -13.3 ± 13.6 LL01942Flll 7 0 -1 -0.1 ± 0.1 -0.6 ± 1.8 15.6 ± 16.1 LL01943F112 7 -22 0 0.5 ± 1.2 0.2 ± 2.0 -5.8 ± 13.2 LL01944F113 -8 55 0 -0.1 ± 0.1 -0.7 ± 1.8 -14.3 ± 11.2 LL01945F114 -8 118 0 -0.1 ± 0.1 0.8 ± 2.4 3.5 ± 16.9 LL01946F115 2 25 0 -0.1 ± 0.1 2.4 ± 2.8 34.3 ± 47.1 LL01947QA N/A N/A N/A 0.5 ± 1.2 2.0 ± 2.8 -1.3 ± 6.7 LL01948TROUGHFA 7 8 0 1.1 ± 1.7 0.8 ± 2.4 -0.1 ± 7.4 LL01949WAIA 23 -13 -1 -0.1 ± 0.1 0.2 ± 2.0 17.2 ± 13.0 LL01950WA2A -8 -98 -1 -0.1 ± 0.1 -0.3 ± 2.0 -5.1 ± 7.3 LL01951WA3A -8 -30 -1 0.5 ± 1.2 0.3 ± 2.2 -3.2 ± 7.2 LL01952WA4A -8 -123 -1 -0.1 ± 0.1 3.3 ± 3.0 -3.1 ± 7.0 LL01953WA5A -8 -68 -1 0.5 ± 1.2 -1.6 ± 1.3 -1.7 ± 8.7 LL01954WA6A -3 -13 0 0.5 ± 1.2 1.3 ± 2.6 -4.2 ± 7.4 LL01955WA7A -13 -174 0 -0.1 * 0.1 0.7 ± 2.2 -4.7 ± 7.4 LL01956WA8A -3 -5 0 -0.1 ± 0.1 1.1 ± 2.6 -1.9 ± 7.5 LL01957WA9A -13 -110 -1 -0.1 ± 0.1 0.3 ± 2.2 2.9 ± 7.7 LL01958WA10A -3 -22 0 -0.1 ± 0.1 0.2 ± 2.0 -2.7 ± 7.3 LL01959WAIB -3 12 0 -0.1 ± 0.1 -2.5 ± 0.5 -1.9 ± 7.4 LL01960WA2B -8 -5 0 -0.1 ± 0.1 0.3 ± 2.2 2.5 ± 7.8 LL01961WA3B -8 -60 -1 0.5 ± 1.2 -0.7 ± 1.6 -3.2 ± 7.2 LL01962WA4B -8 38 -1 -0.1 ± 0.1 0.2 ± 2.2 0.7 ± 7.5 LL01963WA5B -3 -26 .0 0.5 ± 1.2 -0.1 ± 2.0 -3.2 ± 7.2 LL01964WA6B -3 -34 -1 -0.1 ± 0.1 2.0 ± 2.6 -0.6 ± 7.5 LL01965WA7B -8 -60 0 -0.1 ± 0.1 -0.7 ± 1.8 -1.4 ± 7.4 LL01966WA8B -13 0 0 -0.1 ± 0.1 2.6 ± 3.0 -1.9 ± 7.4 LL01967

C-7-3

Page 40: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-7MH-4939-R-97, Facility Close-o'----andTermination Surv, Camr )lmer, NJ, 1 Jul - 20 Dec 97

Camn Kilmer RUILDING 1072 ROOM 5Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cm^2 dpmnl00=cmA2 uPlhr dpmnlOOcmA2 +1-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.79 to 1.25 7.86 to 7.9(MDA>) 52 227 - 2.14 " 2.23 79.65 "

WA9B -3 42 0 0.5 ± 1.2 1.1 ± 2.3 1.2 ± 7.7 LL01968WA10B -8 -110 -1 -0.1 ± 0.1 1.5 ± 2.7 -3.6 ± 7.2 LL01969WA1C -13 -17 -1 -0.1 1 0.1 -1.0 ± 1.6 0.3 ± 7.8 LL01970WA2C -3 -9 0 -0.1 ± 0.1 0.7 ± 2.2 -4.0 ± 6.9 LL01971WA3C 7 190 0 0.5 ± 1.2 -0.7 ± 1.8 -2.3 ± 7.3 LL01972WA4C -8 109 0 -0.1 ± 0.1 -0.1 ± 2.0 1.6 ± 7.7 LL01973WA5C 2 0 0 -0.1 ± 0.1 0.7 ± 2.2 -2.7 ± 7.1 LL01974WA6C -13 114 0 -0.1 ± 0.1 -0.7 ± 1.8 -2.7 ± 7.3 LL01975WA7C -13 12 0 -0.1 ± 0.1 -1.9 ± 1.0 -1.8 ± 7.2 LL01976WABC 2 -9 0 -0.1 ± 0.1 0.2 ± 2.0 -4.4 ± 6.9 LL01977WA9C -3 -38 -1 -0.1 ± 0.1 2.0 ± 2.8 1.6 ± 7.7 LL01978

WA10C -3 -22 -1 -0.1 ± 0.1 -1.0 ± 1.6 -2.7 ± 7.1 LL01979WB1A 7 -13 -1 -0.1 ± 0.1 2.0 ± 2.6 -4.4 ± 6.9 LL01980WB2A -8 -13 -1 -0.1 ± 0.1 -0.3 ± 2.0 -1.4 ± 7.2 LL01981WVBIB -3 -13 -1 0.5 ± 1.2 0.3 ± 2.2 -6.4 ± 7.0 LL01982WB2B -13 -81 0 -0.1 ± 0.1 -1.1 ± 1.3 -2.7 ± 7.1 LL01983WB1C -8 38 -1 -0.1. ± 0.1 -0.3 ± 2.0 0.7 ± 7.6 LL01984WB2C 2 12" 0 -0.1 ± 0.1 -0.6 ±t 1.8 -2.3 ± 7.3 LL01985WC1A '. -3 -5 0 -0.1 ± 0.1 0.7 ± 2.2 -4.9 ± 7.0 LL01986WC2A - -13 63 0 -0.1 ± 0.1 -1.2 ± 1.6 0.7 ± 7.6 LL01987WC3A -8 -43 0 -0.1 ± 0.1 -1.0 ± 1.6 0.3 ± 7.6 LL01988WC4A -3 8 0 0.5 ± 1.2 1.1 ± 2.3 -1.8 ± 7.2 LL01989WC5A -8 55 0 -0.1 ± 0.1 -0.7 * 1.8 -5.7 ± 6.7 LL01990WC6A' -8 -89 0 0.5 ± 1.2 -0.1 ± 2.0 10.9 ± 8.5 LL01991WCIB .8 46 0 -0.1 ± 0.1 0.7 * 2.2 -0.6 ± 7.3 LL01992WC2B -3 4 0 -0.1 ± 0.1 0.2 * 2.2 -1.0 ± 7.3 LL01993WC3B - -3 -47 0 -0.1 ± 0.1 0.8 * 2.4 0.3 * 7.4 LL01994WC4B 2 33 1 -0.1 ± 0.1 -1.1 ± 1.3 -4.9 ± 7.0 LL01995WC5B -3 12 0 -0.1 ± 0.1 0.6 * 2.4 -0.1 ± "7.4 LL01996WC6B -13 -30 0 -0.1 ± 0.1 0.3 ± 2.2 -0.6 ± 7.3 LL01997

WCIC 2 50 0 0.5 ± 1.2 1.6 ± 2.5 -1.4 ± 7.2 LL01998WC2C -8 42 0 0.5 ± 1.2 .0.2 ± 2.2 0.3 ± 7.6 LL01999WC3C -3 12 0 -0.2 ± 0.1 0.0 ± 2.1 -1.9 ± 7.4 LL02000WC4C 2 16 0 -0.2 ± 0.1 3.6 ± 3.1 1.6 ± 7.7 LL02001WC5C -3 -26 1 -0.2 ± 0.2 -0.1 ± 2.2 3.4 ± 7.9 LL02002WC6C -3 -13 0 -0.1 ± 0.1 -1.5 ± 1.0 0.8 ± 7.8 LL02003WD1A -13 -93 0 0.4 ± 1.2 -1.4 ± 1.4 -2.8 ± 7.4 LL02004WD2A -3 80 0 -0.2 ± 0.1 -0.9 ± 1.3 -4.9 ± 7.0 LL02005WD3A 2 -51 0 -0.2 ± 0.2 -0.6 ± 2.1 -1.9 ± 7.4 LL02006

WD4A -3 42 0 -0.1 ± 0.1 3.9 * 3.2 -2.7 ± 7.3 LL02007WD5A -13 -22 0 0.4 ± 1.2 0.0 ± 2.1 1.2 ± 7.7 LL02008WD6A -8 21 0 -0.2 ± 0.1 0.5 ± 2.0 5.6 ± 8.3 LL02009VWD7A -8 -17 0 -0.2 ± 0.2 -0.1 ± 2.2 -4.1 ± 7.3 LL02010WD8A -13 0 0 -0.1 ± 0.1 2.6 ± 2.8 -1.0 ± 7.4 LL02011WD1B 2 -30 1 -0.2 ± 0.1 -0.9 ± 1.7 -1.9 ± 7.4 LL02012

WD2B -8 -17 0 0.5 ± 1.2 -0.4 ± 1.6 1.6 ± 7.7 LL02013

WD3B -3 -22 0 1.0 ± 1.7 1.1 ± 2.4 2.5 ± 7.8 LL02014

WD4B -8 -13 0 -0.2 ± 0.2 -1.0 ± 1.5 1.6 ± 7.9 LL02015

ND5B 7 0 0 -0.2 ± 0.2 -0.2 ± 1.9 0.3 ± 7.6 LL02016

WD6B 2 -30 0 0.4 ± 1.2 -0.6 ± 1.7 0.3 ± 7.6 LL02017

C-7-4

Page 41: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. "'MH-4939-R-97, Facility Close-o,--ndTermination Surv, Camp ._ilmer, NJ, 1 Jul - 20 Dec 97

vnýný E"u nwri 4n7,2 onrim r.

Location Monitoring Wipe TestCode Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/1OOcmA2 dpm/1OOcmA2 uRlhr dpm/1OOcmA2 +1- 2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.79 to 1.25 7.86 to 7.9(MDA=>) 52 .227.. - 2.14 2.23 * 79.65WD7B 2 8 1 -0.2 ± 0.2 0.7 t 2.3 -1.0 t 7.4 LL02018WD8B -3 21 0 -0.2 ± 0.2 0.3 ± 2.1 -2.0 :t 7.7 LL02019WD1C -3 -72 0 -0.2 ± 0.2 0.7 t 2.3 -0.1 ± 7.4 LL02020WD2C 2 42 1 -0.2 ± 0.2 -0.2 ± 1.9 2.6 ± 8.2 LL02021WD3C -8 80 0 -0.2 ± 0.2 0.7 ± 2.3 0.8 ± 7.8 LL02022WD4C -8 67 0 -0.2 ± 0.2 1.1 ± 2.4 -1.9 ± 7.4 LL02023WD5C -3 4 0 0.4 ± 1.2 -1.0 ± 1.5 1.2 ± 8.0 LL02024WD6C .3 -38 0 -0.2 ± 0.2 0.7 ± 2.3 -1.9 ± 7.4 LL02025WD7C -3 12 1 -0.2 ± 0.2 1.1 ± 2.4 -3.6 ± 7.2 LL02026WD8C -3 97 0 0.4 ± 1.2 0.7 ± 2.3 0.8 ± 7.8 LL02027WEIA 12 50 0 0.4 ± 1.2 -0.6 ± 1.7 -1.9 ± 7.4 LL02028WE2A 2 -26 0 3.4 + 2.9 2.8 :t 2.9 0.3 * 7.8 LL02029WE3A 23 -5 0 -0.2 :10.2 -0.6 t 1.7 -1.0 ± 7.4 LL02030WE4A 7 33 0 -0.2-*±: 0.2 0.3 : 2.1 -1.4 ± 7.4 LL02031WE5A 12 -13 0 -0.2 ± 0.2 3.3 ± 3.1 -2.9 ± 7.8 LL02032WE6A -13 147 0 -0.2 + 0.2 0.7 ± 2.3 -1.6 ± 8.1 LL02033WE7A -3 67 0 0.4 ± 1.2 0.3 ± 2.1 -4.4 ± 7.8 LL02034WE8A -13 -13" 0 -0.2 ± 0.2 1.5 ± 2.6 -4.4 ± 7.8 LL02035WE9A 2 25 0 -0.2 ± 0.2 0.3 :t 2.1 1.9 ± 8.9 LL02035WE1OA 7 8 0 -0.2 ± 0.2 -0.2 ± 1.9 -3.3 ± 7.5 LL02037WE11A -13 -64 0 -0.2 ± 0.2 -1.0 ± 1.5 11.0 ± 15.1 LL02038WE12A -13 21 0 -0.2 ± 0.2 2.4 ± 2.8 -1.2 ± 8.8 LL02039WE13A 2 59 0 0.4 ± 1.2 -0.6 ± 1.7 -2.1 ± 8.2 LL02040WE14A -3 -34 0 0.4 ± 1.2 0.7 ± 2.3 4.0 ± 8.3 LL02041WE1SA -8 -55 0 -0.2 ±, 0.2 1.5 ± 2.6 0.3 ± 7.8 LL02042WEIB 2 25 0 -0.2 ± 0.2 1.1 ± 2.4 4.8 ± 8.2 LL02043WE2B 2 ' 38 0 -0.2± 0.2 1.1 ± 2.4 -1.1 ± 7.8 LL02044WE3B 2 84 0 -0.2 ± 0.2 -0.2 .t 1.9 2.1 ± 8.0 LL02045WE4B -3 59 0 1.6 + 2.0 -0.6 ± 1.7 -1.0 ± 7.6 LL02046WE5B 2 88 0 -0.2 ± 0.2 -0.6 ± 1.7 1.3 ± 8.4 LL02047WE6B -3 -38 0 0.4 + 1.2 0.3 ± 2.1 0.3 + 7.8 LL02048WE7B 7 -26 0 -0.2. ± 0.2 0.7 * 2.3 -0.1 : 8.1 LL02049WE8B 7 25 0 0.4 ± 1.2 0.7 ± 2.3 8.1 ± 8.7 LL02050WE9B -3 33 0 -0.2 ± 0.2 -0.6 ± 1.7 -1.5 ± 7.9 LL02051WE10B 7 50 0 0.4 ± 1.2 1.5 ± 2.6 -2.2 ± 8.7 LL02052WE11B 7 8 0 0.4 ± 1.2 2.4 ± 2.8 -3.2 ± 7.2 LL02053WE12B -8 0 .1 0.4 ± 1.2 -1.0 ± 1.5 -2.9 ± 7.6 LL02054WE13B -8 -9 1 1.0 ± 1.7 2.4 ± 2.8 -3.5 ± 7.9 LL02055WE14B -8 21 0 0.4 ± 1.2 1.1 ± 2.4 2,1 ± 8.1 LL02056VVE15B -8 0 -1 2.2 ± 2.3 2.8 ± 2.9 -1.5 ± 7.6 LL02057WE1C 2 -30 0 0.4 ± 1.2 2.0 ± 2.7 2.2 ± 8.5 LL02058WE2C 12 181 0 0.4 ± 1.2 1.1 ± 2.4 2.4 ± 8.9 LL02059WE3C 17 114 0 1.0 + 1.7 0.3 ± 2.1 -1.1 ± 8.0 LL02060WE4C -3 42 0 5.7 ± 3.7 9.7 ± 4.5 -2.9 ± 7.6 LL02061WE5C -8 97 0 -0.2 ± 0.2 0.7 ± 2.3 -2.9 ± 7.6 LL02062

VE6C -13 0 0 0.4 ± 1.2 1.1 ± 2.4 -2.7 ± 8.4 LL02063WE7C 2 147 0 0.4 ± 1.2 2.0 ± 2.7 1.0 ± 10.3 LL02064WE8C -8 84 0 -0.2 ± 0.2 0.3 ± 2.1 -8.9 ± 7.9 LL02065WE9C 2 109 -1 -0.2 ± 0.2 2.0 ± 2.7 -4.0 ± 7.8 LL02066WE10C -3 67 0 -0.2 ± 0.2 0.3 ± 2.1 -2.1 ± 8.1 ILL02067

C-7-5

Page 42: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 22-MMH-4939-R-97, Facility Close-o'- andTermination Surv, Camý 'lmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 5

Location Monitoring Wipe TestCode Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cmA2 dpml1OOcMA^2 uR/hr dpm/100cm^2 +/-2 sigma Number

(Bkgd=>) 5 0.0 to 0.34 0.79 to 1.25 7.86 to 7.9

CMDA>) 52 227 - 2.14 " 2.23 79.65WE11C -8 139 0 0.4 + 1.2 1.5 ± 2.6 -2.9 + 7.8 LL02068WE12C -3 84 0 -0.2 ± 0.2 0.7 ± 2.3 0.3 ± 8.1 LL02069

WE13C -3 147 0 0.4 + 1.2 0.7 ± 2.3 -0.7 ± 8.8 LL02070

WE14C -13 207 0 -0.4 : 0.2 0.8 ± 2.7 -4.5 + 8.9 LL02071

WE15C 12 84 1 -0.4 :t 0.2 1.3 ± 2.8 -8.7 ± 7.7 LL02072WF1A -8 84 0 0.3 ± 1.3 0.3 ± 2.5 -1.1 ± 8.0 LL02073

WF2A 2 0 0 -0.4 1 0.2 1.8 ± 3.0 -4.2 ± 7.4 LL02074WF3A 2 4 0 0.3 + 1.3 1.3 ± 2.8 -2.4 ± 7.5 LL02075

WF4A 7 -30 0 -0.4 * 0.2 3.4 ± 3.5 -1.0 ± 7.6 LL02076WF5A -13 -47 0 -0.4 ± 0.2 2.3 ± 3.2 1.2 ± 7.7 LL02077

WF6A 2 -26 0 -0.4 ± 0.2 1.3 ± 2.8 2.5 ± 7.8 LL02078WF7A -13 12 0 -0.4 ± 0.2 0.3 ± 2.5 -5.9 ± 7.0 LL02079

WF8A 7 33 0 -0.4 ± 0.2 6.9 ± 4.3 -0.6 ± 7.7 LL02080WF9A 12 63 0 -0.4 ± 0.2 -0.2 ± 2.3 -4.9 ± 7.0 LL02081

WFIB 2 -38 0 -0.4 ±10.2 0.8 ± 2.7 10.3 ± 8.6 LL02082

WF2B 2 46 0 0.3 ± 1.3 1.8 ± 3.0 -2.3 ± 7.3 LL02083WF33B -3 97 1 -0.4 ± 0.2 3.4 ± 3.5 0.3 ± 7.8 LL02084.

WF4B -8 42. 0 -0.4 ± 0.2 -1.2 ± 1.8 5.6 ± 8.3 LL02085

WF5B -3 -34 0 -0.4 ± 0.2 2.3 ± 3.2 -2.3 ± 7.3 LL02086

WF6B13 -13 16 0 -0.4 ± 0.2 -1.2 ± 1.8 -2.3 ± 7.3 LL02087

WF7B -8 33 0 1.0 ± 1.8 4.9 ± 3.9 3.4 ± 7.9 LL02088

WF8B 2 109 0 0.3 ± 1.3 0.8 ± 2.7 0.8 ± 7.8 LL02089

WF9B- -3 -38 -1 1.6 ± 2.2 9.4 ± 4.9 2.5 ± 8.0 LL02090

WFIC -13 -43 0 -0.4 ± 0.2 -0.7 ± 2.0 3.9 ± 8.1 LL02091

WF2C -8 38 0 1.0 ± 1.8 0.3 ± 2.5 4.9 ± 8.4 LL02092

WF3C - -13 0 0 0.3 + 1.3 2.3 ± 3.2 -0.1 ± 7.4 LL02093

WF4C -3 -13 0 1.0 ± 1.8 2.9 ± 3.3 -2.7 ± 7.3 LL02094

WIF5C -8 46 0 1.0 ± 1.8 0.8 ± 2.7 3.4 ± 7.9 LL02095WF6C -13 21 0 1.0 ± 1.8 0.3 ± 2.5 2.0 ± 7.8 LL02096

WF7C -8 -64 0 -0.4 ±t 0.2 -1.2 ± 1.8 0.3 ± 7.6 LL02097

WF8C -3 -30 0 -0.4 ± 0.2 -0.2 ± 2.3 -1.9 ± 7.4 LL02098W1F9C -3 29 0 -0.4 ± 0.2 0.8 ± 2.7 -1.4 ± 7.4 LL02099

Indicates the highest MDA for this survey unit. The Alpha MDA ranged from 1.76 to 2.14 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.88 to 2.23 dpm

Indicates the highest MDA for this survey unit. The H-3 MDA ranged from 12.49 to 79.65 dpm

C-7-6

Page 43: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 1072Room 6

1-d II II III 122 2. L 1 I I I 11VVA 'IVA I I I I I VIA I1A 10A ISA

9C 9A

C A

FA FA FA

Fh I

P21 p,1A

w¶5

LAIC

9C

N

S

BUILDING 1072. ROOM 6. CAMP KILMER. NEW JERSEY DATE- 20 0" 197

DRAWN: MSD

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCALE: NTSUNITED STATES ARMY MEDICAL DEPARTMENT

PLATE: WA

C-8

Page 44: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 7•NH-4939-R-97, Facility Close-o" "and. Termination Surv, Camp-..ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 6Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units >) dpml100cm^2 dpmr100cmA2 uR/hr dpmlO00cm^2 +1-2 sigma Number

(Bkgd=>) 5 0.0 to 0.33 1.07 to 1.22 7.86 to 7.9CMDA =>) 52 298 - 2.49 " 2.5 " 57.93FA1 -3 -497 -1 0.3 ± 1.3 2.9 ± 3.3 -9.2 t 10.9 LL02100FA2 2 -492 -1 -0.4 ± 0.2 -0.2 ± 2.3 21.5 ± 17.3 LL02101FA3 23 -408 -1 0.3 ± 1.3 0.3 ± 2.5 13.1 ± 14.3 LL02102FA4 23 -332 -1 0.3 ± 1.3 1.8 ± 3.0 0.4 ± 10.6 LL02103FA5 33 -344 0 0.3 ± 1.3 -0.7 ± 2.0 0.5 ± 11.3 LL02104FA6 -8 -319 0 -0.4 ± 0.2 2.3 ± 3.2 -4.3 ± 11.5 LL02105FA7 -8 -416 0 -0.4 ± 0.2 0.8 ± 2.7 -7.8 ± 9.3 LL02106FA8 -3 -416 0 -0.4 ± 0.2 3.4 ± 3.5 3.3 ± 10.3 LL02107FA9 2 -344 0 -0.4 ± 0.2 -0.7 + 2.0 -0.8 ± 10.4 LL02108FA10 17 -319 0 2.3 ± 2.6 4.4 ± 3.7 -1.8 ± 9.2 LL02109FAll -13 -408 -1 1.6 ± 2.2 -0.2 ± 2.3 -7.1 ± 10.1 LL02110FA12 7 -328 0 -0.4 ± 0.2 3.4 ± 3.5 -2.8 ± 8.8 LL02111FA13 2 -433 0 0.3 ± 1.3 2.9 ± 3.3 -6.3 ± 8.9 LL02112FA14 -8 -399 0 -0.4 ± 0.2 -0.2 ± 2.3 -9.5 ± 11.3 LL02113FA15 -8 -420 0 1.0 ± 1.8 -0.7 ± 2.0 -8.5 ± 11.0 LL02114FBI -13 -311 0 0.3 ± 1.3 0.8 ± 2.7 -6.9 ± 9.7 LL02115FB2 -8 -399 0- 0.3 ± 1.3 0.8 ± 2.7 2.8 ± 10.5 LL02116FB3 -8 -281 0 -0.4 ± 0.2 0.3 ± 2.5 -8.9 ± 10.6 LL02117FB4 2 -425 0. 3.6 ± 3.2 0.3 ± 2.5 0.4 ± 9.7 LL02118FB5 12 -387 0 0.3 ± 1.3 0.8 ± 2.7 -4.6 ± 10.3 LL02119FB6 -8 -260 0 0.3 ± 1.3 -0.2 ± 2.3 -11.0 ± 12.1 LL02120FB7 -3 -298 0 1.0 ± 1.8 -0.7 ± 2.0 -18.2 ± 16.2 LL02121FB8 17 -277 0 -0.4 ± 0.2 1.3 ± 2.8 -7.9 ± 10.3 LL02122FB9 2 -349 1 1.0 ± 1.8 -0.2 ± 2.3 -4.9 ± 11.0 LL02123FB10 -3 -315 0 -0.4 ± 0.2 1.3 ± 2.8 -12.3 ± 9.1 LL02124FB11 2 -239 0 -0.4 ± 0.2 2.3 ± 3.2 -4.9 ± 9.7 LL02125FB12 -8 -370 0 -0.4 ± 0.2 -1.2 ± 1.8 -10.8 ± 9.6 LL02126FB13 -3 -382 0 -0.4 + 0.2 3.9 ± 3.6 -6.9 ± 9.7 LL02127FB14 12 -437 0 -0.1 ± 0.1 1.2 ± 3.1 -13.9 ± 9.2 LL02128FB15 -8 -416 0 0.7 ± 1.5 2.3 ± 3.5 -8.5 ± 8.7 LL02129FC1 -8 -391 1 -0.1 ± 0.1 -1.1 ± 2.3 -8.3 ± 9.9 LL02130FC2 12 -167 0 -0.1 ± 0.1 -1.1 ± 2.3 -9.5 ± 12.3 LL02131FC3 -8 -344 1 1.5 ± 2.2 0.1 ± 2.7 -11.0 ± 12.1 LL02132FC4 -3 -302 1 -0.1 ± 0.1 1.7 ± 3.3 -6.9 ± 10.8 LL02133FC5 2 -82 1 -0.1 + 0.1 1.7 ± 3.3 -4.9 ± 11.0 LL02134FC6 -3 -277 1 -0.1 ± 0.1 -0.5 ± 2.5 -1.9 ± 14.3 LL02135FC7 -8 -306 0 1.5 ± 2.2 1.2 ± 3.1 -6.3 ± 8.9 LL02136FC8 -3 -281 0 -0.1 + 0.1 0.1 ± 2.7 -7.8 ± 11.1 LL02137FC9 2 -281 0 -0.1 ± 0.1 1.7 ± 3.3 -0.9 ± 11.9 LL02138FC10 7 -294 0 -0.1 ± 0.1 2.3 ± 3.5 -4.7 ± 9.4 LL02139FC11 2 -315 0 0.7 ± 1.5 0.1 ± 2.7 -3.9 ± 10.4 LL02140FC12 -8 -298 0 -0.1 ± 0.1 1.7 ± 3.3 4.7 ± 11.0 LL02141FC13 2 -450 0 -0.1 ± 0.1 1.2 ± 3.1 -5.4 ± 12.3 LL02142FC14 2 -349 0 1.5 ± 2.2 -0.5 ± 2.5 -11.9 ± 10.6 LL02143FC15 -3 -378 1 1.5 ± 2.2 1.7 ± 3.3 -7.8 ± 9.3 LL02144FD1 12 -251 1 0.7 ± 1.5 2.3 ± 3.5 -6.9 ± 10.8 LL02145FD2 2 -213 0 0.7 ± 1.5 -2.7 ± 1.2 -2.4 ± 12.6 LL02146FD3 -3 -137 0 -0.1 ± 0.1 1.2 ± 3.1 -8.4 ± 11.9 LL02147FD4 -8 -277 0 0.7 ± 1.5 1.2 ± 3.1 -8.9 ± 15.5 LL02148FD5 2 -112 0 -0.1 ± 0.1 1.2 ± 3.1 -10.6 ± 10.8 LL02149

C-8-1

Page 45: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. * C-MH-4939-R-97, Facility Close-Noy0OandTermination Surv, Cami )lmer, NJ, 1 Jul - 20 Dec 97 1 1

Camp Kilmer, BUILDING 1072 ROOM 6Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/100cmA2 dpmnl00cmA2 uRlhr dpnmlc00=1^2 +1-2 sigma Number

(Bkgd=>) 5 0.0 to 0.33 1.07 to 1.22 7.86 to 7.9

(MDA >) 52 298 - 2.49 * 2.5 * 57.93 *

FD6 17 -361 0 -0.1 ± 0.1 1.7 ± 3.3 -1.1 ± 14.4 LL02150

FD7 2 -171 0 -0.1 ± 0.1 -1.6 ± 2.0 -9.5 ± 12.3 LL02151

FD8 -3 -260 0 -0.1 ± 0.1 2.3 ± 3.5 -2.3 ± 11.7 LL02152

FD9 -8 -298 0 -0.1 ± 0.1 2.8 ± 3.6 -5.4 ± 10.6 LL02153

FD10 2 -260 0 -0.1 ± 0.1 0.6 ± 2.9 -3.6 ± 9.5 LL02154

FD11 -3 -180 0 -0.1 ± 0.1 0.6 ± 2.9 -0.9 ± 12.3 LL02155

FD12 -8 -294 0 -0.1 ± 0.1 0.1 ± 2.7 -9.0 ± 9.2 LL02156

FD13 12 -273 0 -0.1. ± 0.1 1.2 ± 3.1 -11.4 ± 9.5 LL02157

FD14 -13 .281 0 -0.1 ± 0.1 2.8 ± 3.6 44.9 ± 36.2 LL02158

FD15 2 -353 0 -0.1 ± 0.1 0.6 ± 2.9 -6.7 ± 10.5 LL02159

FE1 -3 -361 0 -0.1 ± 0.1 1.7 ± 3.3 -9.0 ± 14.1 LL02160

FE2 -8 -125 0 0.7 ± 1.5 -1.1 ± 2.3 -8.1 ± 9.6 LL02161

FE3 12 -197 0 -0.1 ± 0.1 0.1 ± 2.7 -5.2 ± 11.8 LL02162

FE4 -3 -277 0 -0.1 ± 0.1 0.6 ± 2.9 -4.7 ± 12.4 LL02163

FE5 2 -239 0 1.5 ± 2.2 4.5 ± 4.1 -4.4 ± 10.0 LL02164

FE6 -3 -247 0 -0.1 ± 0.1 0.1 ± 2.7 -6.7 ± 10.5 LL02165

FE7 28 -353 1 -0.1 ± 0.1 -2.2 ± 1.6 -11.7 ± 9.2 LL02166

FES -3 -235 1 -0.1 ± 0.1 2.3 ± 3.5 -13.1 ± 9.7 LL02167

FE9 - -3 -323 0 -0.1 ± 0.1 0.6 ± 2.9 -5.5 ± 9.6 LL02168

FE10 - -13 -340 0 0.7 ± 1.5 0.6 ± 2.9 -9.2 ± 10.1 LL02169

FEll -3 -336 0 0.7 ± 1.5 1.7 ± 3.3 -14.2 ± 9.9 LL02170

FE12 2 -226 0 -0.1 ± 0.1 0.1 ± 2.7 -13.1 ± 9.7 LL02171

FE13 12 -311 1 0.7 ± 1.5 1.2 ± 3.1 -17.7 ± 13.0 LL02172

FE14 7 -273 0 1.2 ± 2.2 1.9 ± 3.3 -15.1 ± 16.5 LL02173

FE15 - 17 -391 0 -0.3 ± 0.2 2.5 ± 3.5 -16.4 . ± 11.4 LL02174

FF1 .. -3 -235 0 -0.3 ± 0.2 -0.3 ± 2.5 -15.0 ± 11.1 LL02175

FF2 -13 -294 0 -0.3 ± 0.2 -0.3 ± 2.5 -8.3 ± 9.9 LL02176

FF3 -8 -277 0 0.4 ± 1.5 0.8 ± 2.9 -10.2 ± 9.7 LL02177

FF4 17 -175 0 1.2 ± 2.2 2.5 ± 3.5 -7.9 ± 10.3 LL02178

FF5 -8 -129 0 -0.3 ± 0.2 5.2 ± 4.2 -6.9 ± 9.7 LL02179

FF6 -13 -281 0 -0.3 ± 0.2 5.2 ± 4.2 -9.4 ± 13.4 LL02180

FF7 -8 -251 0 -0.3 ± 0.2 1.4 ± 3.1 -13.3 ± 10.4 LL02181

FF8 -8 -302 0 -0.3 ± 0.2 1.9 ± 3.3 -5.3 ± 16.8 LL02182

FF9 2 -306 0 -0.3 ± 0.2 -0.3 ± 2.5 -11.0 ± 12.1 LL02183

FF10 -3 -243 0 -0.3 ± 0.2 -2.0 ± 1.6 -11.5 ± 10.2 LL02184

FF11 2 -268 0 1.2 ± 2.2 1.9 ± 3.3 -10.2 ± 9.7 LL02185

FF12 -8 -273 0 0.4 ± 1.5 0.8 ± 2.9 -15.7 ± 18.6 LL02186

FF13 -13 -302 0 0.4 ± 1.5 0.2 ± 2.7 -17.2 ± 16.3 LL02187

FF14 7 -171 1 -0.3 ± 0.2 0.2 ± 2.7 -11.3 ± 11.6 LL02188

FF15 -3 -311 0 -0.3 ± 0.2 3.6 ± 3.8 -12.8 ± 13.0 LL02189

FG1 -3 -319 0 0.4 ± 1.5 1.9 ± 3.3 -9.1 ± 11.8 LL02190

FG2 7 -361 0 -0.3 ± 0.2 0.8 ± 2.9 -14.4 ± 9.5 LL02191

FG3 -8 -357 1 -0.3 ± 0.2 0.8 ± 2.9 -11.2 ± 10.7 LL02192

FG4 -8 -251 0 0.4 ± 1.5 0.2 ± 2.7 -19.5 ± 10.5 LL02193

FG5 -8 -251 0 -0.3 ± 0.2 1.4 ± 3.1 -15.0 ± 9.4 LL02194

FG6 -8 -281 0 -0.3 ± 0.2 0.8 ± 2.9 -19.4 ± 13.5 LL02195

FG7 23 -294 0 -0.3 ± 0.2 1.4 ± 3.1 -12.8 ± 13.0 LL02196

FG8 -8 -201 0 0.4 ± 1.5 2.5 ± 3.5 -8.5 ± 11.0 LL02197

FG9 17 -264 0 1.2 ± 2.2 0.2 ± 2.7 -7.9 ± 10.3 LL02198

FG10 12 -260 0 0.4 ± 1.5 1.9 ± 3.3 -11.1 ± 9.2 LL02199

C-8-2

Page 46: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27--'H-4939-R-97, Facility Close-ou>--,ndTermination Surv, Camp A.mer, NJ, 1 Jul - 20 Dec 97''.... )

Camp Kilmer, BUILDING 1072 ROOM 6.Location Monitoring , Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100=cA2 dpm/100cmA2 uRlhr dprm,1OOcMA2 +1- 2 sigma Number(Bkgd >) 5 0.0 to 0.33 1.07 to 1.22 7.86 to 7.9(MDA =>) 52 298 2.49 2.5 *... 57.93 *FG11 2 -315 0 -0.3 ± 0.2 -2.0 ± 1.6 -7.5 ± 10.7 LL02200FG12 2 -116 0 -0.3 ± 0.2 -0.9 ± 2.2 -13.9 ± 9.2 LL02201FG13 -13 -264 0 -0.3 ± 0.2 1.4 ± 3.1 -29.6 ± 28.1 LL02202FG14 -3 -306 0 -0.3 ± 0.2 0.2 ± 2.7 -7.8 ± 13.6 LL02203

FG15 -8 -213 0 -0.3 ± 0.2 -0.3 ± 2.5 -7.7 ± 10.0 LL02204FH1 -3 -298 0 -0.3 ± 0.2 2.5 ± 3.5 -15.0 ± 13.3 LL02205FH2 -3 -323 0 0.4 ± 1.5 -1.4 ± 2.0 -11.2 ± 10.7 LL02206

FH3 7 -251 0 -0.3 ± 0.2 4.7 ± 4.1 -8.9 ± 9.8 LL02207FH4 23 -336 -1 0.4 ± 1.5 -0.9 ± 2.2 -6.6 ± 15.1 LL02208FH5 7 -281 0 -0.3 ± 0.2 -1.4 ± 2.0 3.6 ± 13.8 LL02209

FH6 2 -251 0 -0.3 ± 0.2 -0.3 ± 2.5 -. 5.2 ± 11.8 LL02210FH7 -8 -306 1 -0.3 ± 0.2 -0.9 ± 2.2 -14.0 ± 10.3 LL02211FH8 -13 -167 0 -0.3 ± 0.2 0.2 ± 2.7 -4.5 ± 11.9 LL02212FH9 2 -273 0 1.2 ± 2.2 1.9. ± 3.3 -7.5 ± 10.7 LL02213-

FH10 2 -336 0 0.4 ± 1.5 -0.9 ± 2.2 -15.7. ± 9.3 LL02214FHri -8 -357 0 0.4 ± 1.5 1.9 ± 3.3 -9.3 ± 8.8 LL02215

FH12 -8 -209 0 -0.3 ± 0.2 0.2 ± 2.7 . -5.8 ± 10.2 LL02216FH13 -8 -387. 0 -0.3 :10.2 1.9 ± 3.3 6.7 ± 12.7 LL02217FH14 17 -285 0 0.8 ± 1.7 2.2 ± 2.8 -12.2, ± 12.5 LL02218FH15 -13 -260 0 0.2 ± 1.2 2.7 ± 2.9 -7.9 ± 15.7 LL02219FI1 7 -315 0 1.4 ± 2.0 -0.8 ± 1.7 -11.9 ± 13.1 LL02220F12 -8 -302 0 0.8 ± 1.7 1.8 ± 2.7 -8.6 ± 13.5 LL02221F13 -13 -336 0 0.8 ± 1.7 -0.8 ± 1.7 -6.2 ± 10.9 LL02222F14 12 -294 .0 0.2 ± 1.2 1.8 ± 2.7 -11.4 ± 12.6 LL02223F15 7 -285 0 0.8 ± 1.7 1.8 ± 2.7 -15.9 ± 13.2 LL02224F16 2 -285 0 2.0 ± 2.3 2.7 ± 2.9 -9.9 ± 10.1 LL02225F17 7 -205 0 0.2 ± 1.2 1.8 ± 2.7 -13.3 ± 11.8 LL02226F18 j -3 -235 0 3.2 ± 2.9 0.9 ± 2.4 -7.3 ± 10.4 LL02227F19 7 .- 251 0 0.2 ± 1.2 -0.8 ± 1.7 -5.9 ± 11.7 LL02228

FI10 -13 -323 0 0.8 ± 1.7 2.2 ± 2.8 -9.5 ± 10.5 LL02229

F111 7 -239 0 -0.4 ± 0.2 -0.3 ± 1.9 -7.3 ± 10.4 LL02230F112 -3 -201 0 1.4 ± 2.0 0.5 ± 2.3 -9.4 ± 14.7 LL02231F113 28 -167 0 -0.4 ± 0.2 -0.8 ± 1.7 -8.2 ± 13.0 LL02232

F114 -3 -247 0 0.8 ± 1.7 2.7 ± 2.9 -8.4 ± 11.9 LL02233F115 7 -268 0 0.2. ± 1.2 0.1 ± 2.1 -20.3 ± 14.1 LL02234"QA , N/A N/A NIA 0.8 ± 1.7 -1.2 ± 1.5 -4.2 ± 8.2 LL02235WAlA 33 -488 0 -0.4 ± 0.2 0.1 ± 2.1 -3.9 ± 7.6 LL02236WA2A 2 -370 0 0.8 ± 1.7 -0.3 ± 1.9 -0.1. ± 7.5 LL02237WA3A -3 -366 -1 2.6. ± 2.6 0.9 ± 2.4. -2.7 ± 7.1 LL02238WA4A -3 -395 -1 0.8 ± 1.7 0.9 ± 2.4 -3.7 ± 7.3 LL02239WA5A 17 -332 -1 0.2 ± 1.2 -0.3 ± 1.9 -0.1 ± 7.9 LL02240

WA6A -3 -391 -1 -0.4 ± 0.2 -1.2 ± 1.5 -2.3 ± 7.3 LL02241WA7A 2 -349 -1 -0.4 ± 0.2 1.8 ± 2.7 2.1 ± 8.0 LL02242WASA 2 -404 -1 -0.4 ± 0.2 0.9 ± 2.4 -5.7 ± 6.6 , LL02243WA9A 2 -395 0 -0.4 ± 0.2 -0.8 ± 1.7 -1.0 ± 7.4 LL02244WA1OA 12 -408 -1 -0.4 ± 0.2 1.4 ± 2.6 0.3 ± 7.9 LL02245

WA11A 7 -332 0 1.4 ± 2.0 -0.8 ± 1.7 -1.9 ± 7.4 LL02246WA12A 12 -302 1 0.2 ± 1.2 0.1 ± 2.1 0.8 ± 7.8 LL02247WA13A -8 -357 0 0.2 ± 1.2 0.9 ± 2.4 -0.5 ± 7.2 LL02248WA14A -3 -319 0 0.2 ± 1.2 -1.6 ± 1.3 -0.6 ± 7.7 LL02249

C-8-3

Page 47: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

CIndust Radn Surv No. 2-KMH-4939-R-97, Facility Close- 07 ROOM andTermination Surv, Cam{f >Umer, NJ, 1 Jul - 20 Dec 97

Camn Kilmer. BUILDING 1072 ROOM 6Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpmr/100cm^2 dprmlO00cmA2 uR/hr dpm/100cm^2 +1-2 sigma Number

(Bkgd >) 5 0.0 to 0.33 1.07 to 1.22 7.86 to 7.9

(MDA >) 52 298 - 2.49 2.5 * 57.93 *

WA15A 7 -442 0 -0.4 ± 0.2 -0.8 ± 1.7 -2.4 ± 7.5 LL02250

WAIB 7 -353 0 -0.4 ± 0.2 -0.3 ± 1.9 1.7 ± 8.1 LL02251

WA2B -8 -454 0 0.2 ± 1.2 0.5 ± 2.3 -4.1 ± 7.3 LL02252

WA3B 2 -323 0 -0.4 ± 0.2 -1.2 ± 1.5 -3.8 ± 7.5 LL02253

WA4B -8 -420 0 0.2 ± 1.2 1.8 ± 2.7 1.2 ± 7.9 LL02254WA5B 12 -306 0 0.2 ± 1.2 2.7 ± 2.9 -0.1 t 7.9 LL02255

WA6B 7 -366 0 0.8 ± 1.7 0.9 ± 2.4 -1.5 t 7.6 -L02256

WA7B -8 -357 -1 0.8 ± 1.7 0.9 ± 2.4 -3.3 ± 7.5 LL02257WA8B 2 -285 -1 0.2 ± 1.2 0.1 ± 2.1 0.8 ± 7.8 LL02258

WA9B 17 -437 -1 -0.4 ± 0.2 0.5 ± 2.3 -1.0 ± 7.6 LL02259

WA10B 38 -361 0 -0.4 ± 0.2 -1.2 ± 1.5 0.7 ± 7.6 LL02260

WA11B 17 -336 0 4.4 ± 3.3 3.5 ± 3.2 1.2 ± 7.7 LL02261

WA12B 12 -370 0 -0.4 ± 0.2 -0.8 ± 1.7 -3.7 ± 7.3 LL02262

WA13B 7 -353 0 -0.4 ± 0.2 -0.3 ± 1.9 -5.9 ± 7.0 LL02263

WA14B 33 -387 0 -0.4 ± 0.2 -0.8 ± 1.7 0.3 ± 7.8 LL02264

WA15B 7 -349 0 2.6 ± 2.6 9.5 ± 4.5 -5.5 ± 7.1 LL02265

WA1C 17 -391 0 -0.4 ± 0.2 0.5 ± 2.3 -0.1 ± 7.5 LL02266

WA2C 2 -416 0 -0.4 ± 0.2 -0.8 ± 1.7 -0.6 ± 8.0 LL02267

WA3C 7 -387 -1 1.4 ± 2.0 1.8 ± 2.7 2.1 ± 8.0 LL02268

WA4C -3 -382 0 -0.4 ± 0.2 1.4 ± 2.6 -0.1 ± 7.7 LL02269

WA5C -3 -370 0 0.8 ± 1.7 -0.8 ± 1.7 -6.5 ± 7.1 LL02270

WA6C -13 -366 0 -0.4 ± 0.2 0.1 ± 2.1 -0.1 ± 7.9 LL02271

WA7C 17 -420 0 0.8 ± 1.7 -0.8 ± 1.7 -2.9 ± 7.8 LL02272

WA8C 7 -188 0 0.2 ± 1.2 0.5 ± 2.3 8.3 ± 8.6 LL02273

WA9C 33 -264 0 0.2 ± 1.2 .0.3 ± 1.9 -2.4 ± 7.5 LL02274

WA10C- 2 -298 0 0.8 ± 1.7 0.5 ± 2.3 1.2 ± 7.7 LL02275

WA11C.. -3 -268 0 -0.4 ± 0.2 -1.6 ± 1.3 0.7 ± 7.6 LL02276

WA12C 7 -311 0 -0.4 ± 0.2 -0.3 ± 1.9 1.2 ± 7.9 LL02277

IWA13C 7 -281 0 -0.4 ± 0.2 0.1 ± 2.1 5.5 ± 8.1 LL02278

IWA14C 12 -382 0 0.8 ± 1.7 0.5 ± 2.3 -6.7 ± 6.8 LL02279

WA15C -8 -332 0 -0.4 ± 0.2 -0.3 ± 1.9 -3.2 ± 7.4 LL02280WBIA 7 -475 0 -0.4 ± 0.2 -0.3 ± 1.9 -2.8 ± 7.4 LL02281

WB2A -8 -306 0 -0.4 ± 0.2 1.4 ± 2.6 -5.5 ± 7.1 LL02282

WB3A 2 -349 0 0.2 ± 1.2 -1.6 ± 1.3 1.2 ± 7.9 LL02283WB4A 7 -323 0 -0.4 ± 0.2 0.1 ± 2.1 -0.6 ± 7.8 LL02284

WB5A -8 -429 0 -0.4 ± 0.2 2.2 ± 2.8 -3.8 ± 7.5 LL02285

WB6A -13 -361 0 0.2 ± 1.2 -0.8 ± 1.7 -2.4 ± 7.5 LL02286

WB7A -3 -446 0 -0.4 ± 0.2 0.5 ± 2.3 5.2 ± 8.3 LL02287

WB8A 7 -395 0 -0.4 ± 0.2 0.5 ± 2.3 -0.6 ± 7.8 LL02288WB9A 17 -404 1 -0.4 ± 0.2 0.9 ± 2.4 0.3 ± 7.8 LL02289

WBIB 12 -366 1 0.2 ± 1.2 -1.6 ± 1.3 -4.6 ± 7.2 LL02290

WB2B 7 -319 1 -0.4 ± 0.2 -0.3 ± 1.9 -4.5 ± 7.0 LL02291WB3B 23 -323 0 0.2 ± 1.2 1.4 ± 2.6 12.5 ± 8.8 LL02292

WB4B -8 -420 0 -0.4 ± 0.2 -0.3 ± 1.9 -1.5 ± 7.6 LL02293

WB5B -3 -239 0 -0.4 ± 0.2 -1.2 ± 1.5 -1.9 ± 7.4 LL02294

WB6B 7 -361 0 0.2 ± 1.2 0.1 ± 2.1 -0.6 ± 7.7 LL02295

WB7B 12 -294 0 0.8 ± 1.7 0.5 ± 2.3 -5.2 ± 6.8 LL02296

WB8B 7 -378 0 -0.4 ± 0.2 0.9 ± 2.4 1.6 ± 7.6 LL02297

WB9B 12 -306 0 0.2 ± 1.2 -0.3 ± 1.9 -5.4 ± 6.9 LL02298

WB1C 12 -340 0 -0.4 ± 0.2 -1.2 ± 1.5 -3.0 ± 7.9 LL02299

C-8-4

Page 48: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2'>7Cp4939-R-97, Facility Close -ov)nd-Termination Surv, Camp _Llmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 6Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpnmlOcm^2 dpml/ 00cmA2 uRlhr dpnhl00cmA2 +/-2 sigma Number

(Bkgd >) 5 0.0 to 0.33 1.07 to 1.22 7.86 to 7.9

(MDA >) 52 298 - 2.49 - 2.5 * 57.93W/B2C -8 -425 0 -0.4 ± 0.2 -0.8 * 1.7 -2.4 ± 7.5 LL02300WB3C -3 -357 0 0.2 ± 1.2 -0.3 ± 1.9 -0.6 ± 7.8 LL02301I/B4C -3 -243 0 1.4 ± 2.0 -2.5 ± 0.5 -0.6 ± 7.8 LL02302WB5C 7 -201 0 -0.4 ± 0.2 0.9 ± 2.4 1.7 ± 8.1 LL02303WB6C -8 -277 0 -0.4 ± 0.2 -0.8 ± 1.7 -5.5 ± 7.1 LL02304WB7C -3 -357 0 -0.4 ± 0.2 1.8 ± 2.7 -0.6 ± 7.7 LL02305;WB8C 23 -251 0 -0.4 ± 0.2 -1.2 ± 1.5 3.0 ± 8.1 LL02306WVB9C -13 -306 0 -0.4 ± 0.2 -0.3 ± 1.9 2.1 ± 8.0 LL02307WC1A 12 -378 0 0.2 ± 1.2 0.9 ± 2.4 0.8 ± 7.8 LL02308WC2A -3 -336 0 -0.4 ± 0.2 -0.8 ± 1.7 0.3 ± 7.9 LL02309WC3A -13 -387 0 -0.4 ± 0.2 0.1 ± 2.1 -0.1 ± 7.7 LL02310WC4A -3 -336 1 -0.4 ± 0.2 0.1 ± 2.1 2.9 ± 7.9 LL02311WC5A -3 -247 0 1.2 ± 1.8 3.0 ± 3.5 2.5 ± 8.0 LL02312WC6A -8 -332 0 -0.1 ± 0.1 -0.6 ± 2.3 6.7 ± 8.6 LL02313WC7A 2 -344 1 1.8 ± 2.2 -0.1 ± 2.5 -2.4 ± 7.5 LL02314WC8A 28 -294 0 1.2 ± 1.8 -1.6 ± 1.8 0.3 ± 7.8 LL02315IWC9A 2 -243 0 -0.1 ± 0.1 -0.1 ± 2.5 -0.1 ± 7.9 LL02316WC1OA 7 -387 0 0.5 ± 1.3 -0.1 ± 2.5 2.5 ± 8.0 LL02317WC11A -13 -319 0 1.2 ± 1.8 0.5 * 2.7 -0.6 ± 7.7 LL02318WC12A -8 -366 0 -0.1 ± 0.1 1.0 ± 2.9 1.7 ± 8.1 LL02319WC13A -8 -361 0 -0.1 ± 0.1 1.0 ± 2.9 -2.4 ± 7.5 LL02320WC14A -8 -273 0 1.2 ± 1.8 3.0 ± 3.5 0.3 ± 7.8 LL02321WC15A -13 -273 0 1.2 ± 1.8 -2.6 ± 1.1 -1.1 ± 7.8 LL02322WC1B 2 -256 0 0.5 ± 1.3 -0.1 ± 2.5 2.2 ± 8.5 LL02323WC2B -13 -302 0 0.5 ±, 1.3 -0.6 ± 2.3 -0.2 ± 8.7 LL02324WC3B 2 -260 0 -0.1 ± 0.1 1.0 ± 2.9 0.4 ± 10.0 LL02325WC4B 7 -319 0 1.2 ± 1.8 1.0 ± 2.9 -2.1 ± 8.1 LL02326WC5B 2 -222 0 0.5 ± 1.3 1.5 ± 3.0 -5.7 ± 9.0 LL02327WC6B 12 -243 0 1.2 ± 1.8 1.5 ± 3.0 -6.5 ± 8.4 LL02328WC7B -3 -184 0 3.8 ± 3.2 2.5 ± 3.3 -2.5 ± 8.0 LL02329WC8B -8 -226 0 0.5 ± 1.3 0.5 ± 2.7 -4.8 ± 7.5 LL02330WC9B -3 -298 0 5.8 ± 3.9 8.5 ± 4.8 -0.1 ± 8.3 LL02331WC10B 7 -243 0 0.5 ± 1.3 -2.1 ± 1.5 -5.8 ± 8.3 LL02332WC11B 7 -328 0 -0.1 ± 0.1 2.5 ± 3.3 -5.4 ± 7.7 LL02333WC12B -13 -230 0 1.2 ± 1.8 -0.6 ± 2.3 -2.1 ± 8.1 LL02334WC13B -3 -175 1 1.8 ± 2.2 1.5 ± 3.0 -0.2 ± 9.1 LL02335WC14B 2 -218 0 -0.1 ± 0.1 1.5 ± 3.0 -4.9 ± 7.7 LL02336ýVC15B -3 -302 -1 0.5 ± 1.3 1.0 ± 2.9 -4.1 ± 8.0 LL02337WC1C 2 -251 0 1.2 ± 1.8 0.5 + 2.7 -2.5 ± 8.0 LL02338WC2C 12 -289 -1 -0.1 ± 0.1 2.5 ± 3.3 -5.0 ± 7.9 LL02339WC3C -8 -251 0 -0.1 ± 0.1 2.5 ± 3.3 -1.1 ± 7.8 LL02340WC4C -3 -273 0 0.5 ± 1.3 -1.1 ± 2.1 -1.7 ± 8.5 LL02341WC5C -3 -289 0 -0.1 ± 0.1 1.0 ± 2.9 -6.5 ± 7.7 LL02342

C6C 2 -251 0 -0.1 ± 0.1 -0.6 ± 2.3 1.8 ± 8.5 LL02343WC7C -13 -264 0 -0.1 ± 0.1 -0.6 ± 2.3 -0.6 ± 8.0 LL02344WC8C -3 -133 0 1.2 ± 1.8 1.0 ± 2.9 0.4 ± 8.9 LL02345WC9C -3 -175 0 0.5 ± 1.3 0.5 ± 2.7 4.6 ± 8.8 LL02346WC10C 2 -192 0 0.5 ± 1.3 3.5 ± 3.6 -6.8 ± 8.1 LL02347WC11C -13 -154 1 0.5 ± 1.3 2.5 ± 3.3 -10.4 ± 7.2 LL02348WC12C -8 -205 0 0.5 ± 1.3 0.5 ± 2.7 -2.7 ± 8.4 LL02349

C-8-5

Page 49: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2"-MH-4939-R-97, Facility Close-o-">andTermination Surv, Cam, ýimer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 6Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units >) dpm/ lOOCmA2 dpm/100cmA2 uRlhr dpm/1OOcmA2 +/-2 sigma Number(Bkgd =>) 5 0.0 to 0.33 1.07 to 1.22 7.86 to 7.9(MDA >) 52 298 .- 2.49 2.5 " 57.93 *WC13C -13 -158 0 0.5 - 1.3 1.0 ± 2.9 -4.2 ± 9.5 LL02350WC14C 12 -235 0 -0.1 ± 0.1 1.5 ± 3.0 -1.8 ± 9.2 LL02351WC15C -13 -285 0 -0.1 ± 0.1 1.5 ± 3.0 -4.2 ± 8.2 LL02352WD1A -8 -378 0 -0.1 ± 0.1 1.5 ± 3.0 -2.0 ± 7.9 LL02353WD2A -3 -446 1 -0.1 ± 0.1 -0.6 ± 2.3 1.2 + 7.9 LL02354WD3A 7 -306 0 -0.1 ± 0.1 -0.1 ± 2.5 -0.6 ± 7.7 LL02355WD4A -3 -344 1 0.5 ± 1.3 1.5 ± 3.0 2.0 ± 7.8 LL02356WDSA 2 -277 1 0.5 ± 1.3 6.0 ± 4.2 2.5 ± 8.0 LL02357WD6A 7 -302 1 0.5 ± 1.3 -1.1 ± 2.1 1.6 ± 7.9 LL02358WED7A 2 -412 0 7.1 ± 4.3 3.0 ± 3.5 2.5 ± 7.8 LL02359WD8A 17 -387 1 -0.1 ±-0.1 1.0 ± 2.9 1.2 ± 8.0 LL02360WD9A -3 -425 0 1.2 ± 1.8 1.0 ± 2.9 -1.1 ± 8.0 LL02361WD1B -3 -289 0 -0.1 ± 0.1 1.5 ± 3.0 -1.9 ± 7.5 LL02362WD2B 2 -429 0 -0.1 ± 0.1 -0.6 ± 2.3 -2.4 ± 7.5 LL02363WD3B -8 -459 0 0.5 ± 1.3 1.0 ± 2.9 -1.9 ± 7.5 LL02364WD4B -8 -391 0 -0.1 ± 0.1 5.5 ± 4.1 -2.9 ± 7.6 LL02365WD5B 7 -247 0 -0.1 ± 0.1 2.5 ± 3.3 -0.6 ± 7.7 LL02366VVD6B 2 -366 0 -0.1 ± 0.1 2.5 ± 3.3 0.3 ± 7.6 LL02367WD7B 2 -349 0 -0.1 ± 0.1 0.5 ± 2.7 -0.1 ± 7.7 LL02368WD8B 17 -395 0 0.5 ± 1.3 1.0 ± 2.9 1.2 ± 8.0 LL02369VVD9B -13 -387 0 -0.1 ± 0.1 1.0 ± 2.9 5.5 ± 8.1 LL02370W01C -3 -395 0 0.5 ± 1.3 -0.1 ± 2.5 0.3 ± 7.9 LL02371WD2C 7 -420 0 1.2 ± 1.8 2.5 ± 3.3 3.0 ± 8.1 LL02372WD3C 2 -437 0 -0.1 ± 0.1 1.0 ± 2.9 1.2 ± 7.7 LL02373WD4C ... -3 -344 0 -0.1 ± 0.1 -1.6 ± 1.8 3.1 ± 8.2 LL02374WC5C ..- -13 -357 0 -0.1 ± 0.1 -0.6 ± 2.3 0.8 ± 7.8 LL02375WD6C .. 12 -374 1 -0.1 ± 0.1 2.5 t 3.3 -8.4 ± 6.4 LL02376WD7C 23 -374 1 1.2 * 1.8 1.0 ± 2.9 -3.3 ± 7.5 LL02377WD8C -8 -353 0 -0.1 ± 0.1 -1.1 ± 2.1 1.2 ± 7.9 LL02378WD9C -3 -387 0 -0.1 ± 0.1 0.5 ± 2.7 -4.6 ± 7.2 LL02379

Indicates the highest MDA for this survey unit. The Alpha MDA ranged from 1.96 to 2.49 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.93 to 2.5 dpmIndicates the highest MDA for this survey unit. The H-3 MDA ranged from 13.28 to 57.93 dpm

C-8-6

Page 50: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 1072Room 7

fF-~

F-.;;A W1A 4AJ

'A

1AWIB

I

-I-HI-H1A6f

I _- I I I I I I I Z.C I

BUILDING 1072. ROOM 7. CAMP KILMER. NEW JERSEY QATE- 20 OCT 97

DRAWN: MSD

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCALE: NTSUNITED STATES ARMY MEDICAL DEPARTMENT

PLATE: NWA

C-9

Page 51: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. " NMH-4939-R-97, Facility Close-c" "'andTermination Surv, Camp, ,ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 7Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units =>) dpm/100cmA2 dpmn100cmA2 uRlhr dpmJ100cmA2 +/-2 sigma Number(Bkgd >) 5 0.0 to 0.34 0.93 to 1.63 7.86 to 7.9(MDA >) 52 298 - 2 - 2.29 45.52FA5 -3 -306 0 -0.1 + 0.1 0.5 ± 2.7 -11.8 ± 12.0 LL02380FA6 2 -239 0 -0.1 + 0.1 -0.5 ± 2.7 -10.6 ± 11.6 LL02381FA7 2 -357 0 0.5 ± 1.3 -0.6 ± 2.3 -8.1 ± 14.2 LL02382FA8 -8 -366 0 -0.1 ± 0.1 -0.6 ± 2.3 -2.7 ± 10.6 LL02383FB5 17 -95 0 1.8 ± 2.2 1.0 ± 2.9 -22.9 ± 19.0 LL02384FB6 -13 -213 0 0.5 ± 1.3 -0.1 ± 2.5 -23.7 ± 16.5 LL02385FB7 -3 -226 0 -0.1 ± 0.1 2.5 ± 3.3 -23.9 ± 17.6 LL02386FB8 -8 -235 0 1.2 ± 1.8 3.0 ± 3.5 -9.4 ± 14.7 LL02387FC5 -8 -197 0 -0.1 ± 0.1 -2.1 ± 1.5 -22.4 ±. 15.6 LL02388FC6 -8 -142 0 -0.1 ± 0.1 -2.1 ± 1.5 -24.8 ± 16.3 LL02389FC7 -8 -116 0 -0.1 ± 0.1 -1.6 ± 1.8 -8.3 ± 16.4 LL02390FC8 12 -344 0 0.5 ± 1.3 -2.1 ± 1.5 -7.4 ± 13.1 LL02391FD5 2 -163 1 0.5 ± 1.3 0.5 ± 2.7 -24.7 ± 21.9 LL02392FD6 -3 -57 1 -0.1 ± 0.1 2.0 ± 3.2 -24.8 ± 16.3 LL02393FD7 -13 -323 0 -0.1 ± 0.1 -0.6 ± 2.3 -12.1 ± 19.1 LL02394FD8 -8 -285 1 -0.1 ± 0.1 -0.1 ± 2.5 -10.7 ± 13.9 LL02395FE5 -13 -99 1 -0.1 ± 0.1 0.5 ± 2.7 -11.9 ± 16.9 LL02396FE6 -3 -235 1 0.5 ± 1.3 1.5 ± 3.0 -24.3 ± 14.4 LL02397FE7 -13 -273 1 -0.1 ± 0.1 0.5 ± 2.7 -14.4 ± 12.8 LL02398FE8 2 -277 1 -0.1 ± 0.1 1.5 ± 3.0 -2.8 ± 10.9 LL02399FF1 2 -125 0 -0.1 ± 0.1 1.0 t 2.9 -14.6 ± 12.2 LL02400FF2 12 -188 1 -0.1 ± 0.1 .1.0 ± 2.9 -9.3 ± 16.3 LL02401FF3 2 -53 1 -0.1 ± 0.1 -1.6 ± 1.8 -12.6 ± 10.5 LL02402FF4 -8 -213 1 -0.1 ± "0.1 -1.1 ± 2.1 -13.0 ± 12.4 LL02403FF5 -8 -213 1 -0.1 ±. 0.1 -0.6 ± 2.3 -12.8 ± 11.4 LL02404FF6 12 -116 1 -0.1 ± 0.1 1.5 ± 3.0 -9.4 ± 13.4 LL02405FF7 -13 -142 1 -0.1 ± 0.1 2.5 ± 3.3 -8.7 ± 12.4 LL02406FF8 -8 -273 .1 ,1 0.5 ± 1.3 0.5 ± 2.7 -4.6 ± 10.3 LL02407FG1 7 -66 1 -0.1 ± 0.1 -1.1 ± 2.1 -11.9 ± 13.1 LL02408FG2 -13 -99 1 0.8 ± 1.7 -0.6 ± 2.2 -8.7 ± 17.3 LL02409FG3 7 -163 1 0.3 ± 1.2 0.8 ± 2.4 -13.9 ± 14.2 LL02410FG4 2 -108 1 -0.2 ± 0.2 2.4 ± 2.8 -1.3 ± 17.2 LL02411FG5 2 -137 1 0.2 ± 1.2 1.6 ± 3.0 -11.6 ± 11.1 LL02412FG6 12 -213 0 0.3 ± 1.2 1.7 ± 2.7 -9.8 ± 15.4 1L02413FG7 2 -197 0 -0.2 ± 0.2 0.6 ± 2.2 -20.3 ± 16.9 LL02414FG8 2 -256 0 0.2 ± 1.2 -0.2 ± 2.4 -8.5 ± 11.0 LL02415FH1 -13 -2 0 -0.3 ± 0.2 0.8 ± 2.4 -5.7 ± 15.2 LL02416FH2 2 -154 0 -0.2 ± 0.2 1.9 ± 2.6 -9.8 ± 19.3 LL02417FH3 -8 -264 1 -0.4 ± 0.2 -0.6 ± 2.2 -13.0 + 14.3 LL02418FH4 -8 -91 1 0.3 ± 1.2 1.7 ± 2.7 -4.2 ± 13.4 LL02419FH5 -8 -154 2 -0.2 ± 0.2 1.0 ± 2.3 -9.8 ± 17.2 LL02420FH6 17 -70 1 -0.4 ± 0.2 -1.5. ±. 1.9 -11.4 ± 12.6 LL02421FH7 -3 -154 1 -0.3 ± 0.2 0.8, ± 2.4 -6.6 ± 13.2 LL02422FH8 -8 -239 1 -0.2 ± 0.2 2.4 ± 2.8 -10.2 ± 12.2 LL02423FI1 -3 -142 1 -0.4 ± 0.2 -0.2 ± 2.4 -7.3 ± 16.6 LL02424Fl2 23 -133 1 0.9 ± 1.7 1.3 ± 2.6 6.7 ± 15.8 LL02425FI3 -3 -32 1 1.0 ± 1.7 3.3 ± 3.0 -13.3 ± 11.8 LL02426F14 -8 -99 1 -0.4 ± 0.2 0.3 ± 2.6 -2.4 ± 12.2 LL02427FI5 -3 -120 1 0.9 ± 1.7 -0.6 ± 1.8 -6.9 ± 13.7 LL02428F16 -8 -150 1 -0.2 ± 0.2 -0.3 ± 1.8 -1.9 ± 14.3 LL02429

C-9-1

Page 52: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-TMH-4939-R-97, Facility Close-oyy*-andTermination Surv, Camjn Almer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 7Location Monitoring _,... .... Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpmrlOOcmA2 dpml00c^mA2 uR/hr dpm/100cmA2 +/-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.93 to 1.63 7.86 to 7.9

(MDA >) 52 298 2 - 2.29 45.52 _

F17 7 -222 1 -0.4 ± 0.2 0.7 ± 2.7 :6.9 ± 9.7 LL02430

FI8 23 -302 1 0.3 ± 1.2 1.3 ± 2.6 -13.9 ± 9.2 LL02431

WA1A -8 21 1 0.4 ± 1.2 0.6 ± 2.2 -1.1 ± 8.0 LL02432WA2A 17 -22 1 0.2 ± 1.2 -1.1 ± 2.1 -2.0 ± 7.9 LL02433WA3A -8 -85 0 -0.3 ± 0.2 1.3 ± 2.6 -2.4 ± 7.6 LL02434WA4A 7 16 1 -0.2 ± 0.2 -1.2 ± 1.3 -3.3 ± 7.5 LL02435WAIB 7 50 0 -0.4 ± 0.2 -1.1 ± 2.1 -0.6 ± 7.7 LL02436

WA2B -3 -51 0 -0.3 ± 0.2 3.5 ± 3.2 -0.6 ± 7.7 LL02437WA3B -3 -17 0 -0.2 ± 0.2 -0.7 ± 1.6 4.8 ± 8.2 LL02438

WA4B -8 4 0 -0.4 ± 0.2 -1.1 ± 2.1 -1.5 ± 7.6 LL02439

WAIC -3 105 0 -0.3 ± 0.2 -0.6 ± 1.8 -3.7 ± 7.3 LL02440WA2C -3 0 0 -0.2 ± 0.2 -0.3 ± 1.8 -3.9 ± 7.0 LL02441

WA3C -8 25 0 -0.4 ± 0.2 0.3 1 2.6 -7.4 ± 7.0 LL02442

WA4C -8 59 0 -0.3 ± 0.2 1.3 ± 2.6 -2.9 ± 7.6 LL02443WB1A -13 -9 0 -0.2 ± 0.2 0.2 ± 2.0 -7.0 * 7.1 LL02444

WB2A -8 33 0 -0.4 ± 0.2 -0.6 ± 2.2 -5.0 ± 6.7 LL02445

WS3A -8 114 0 "-0.3 ± 0.2" -0.1 ± 2.0 0.3 ± 7.9 LL02446

VB4A -3 59" 0 -0.2 ± "0.2 0.2 ± 2.0 -2.4 ± 7.6 LL02447WB5A. 7 50 0 2.0 ± 2.4 -1.1 ± 2.1 -4.7 ± 7.4 LL02448

WB6A -13 76 0 -0.3 ± 0.2 -0.1 ± 2.0 -2.9 ± 7.6 LL02449

WB7A 2 25 1 0.4 ± 1.2 -0.3 ± 1.8 -1.9 ± 7.5 LL02450

WB8A .. .8 88 0 -0.4 ± 0.2 -1.5 ± 1.9 -2.9 ± 7.6 LL02451

WB9A -3 71 0 -0.3 ± 0.2 -1.0 ± 1.6 -3.3 ± 7.5 LL02452

WBIB -13 25 0 -0.2 ± 0.2 -0.7 ± 1.6 -2.9 ± 7.8 LL02453WB2B ,. -13 59 0 0.8 ± 1.7 -1.5 ± 1.9 -3.3 * 7.5 LL02454

WB3B .. -3 -13 0 -0.3 ± 0.2 0.3 ± 2.2 -4.8 ± 7.5 LL02455

WB4B -.. -13 63 0 0.4 ± 1.2 0.2 ± 2.0 -1.9 ± 7.5 LL02456

W85B -8 42 0 0.2 ± 1.2 -0.2 ± 2.4 -3.4 ± 7.7 LL02457

WB6B -13 -22 0 -0.3 ± 0.2 1.3 ± 2.6 -4.3 ± 7.6 LL02458

WB7B 2 126 0 0.4 ± 1.2 -0.7 ± 1.6 -1.5 ± 7.7 LL02459

WB8B -3 4 1 -0.4 ± 0.2 -0.6 ± 2.2 -1.0 ± 7.6 LL02460WE39B -3 101 1 -0.3 ± 0.2 -1.0 ± 1.6 -6.1 ± 7.2 LL02461

WB1C -3 16 0 -0.2 ± 0.2 0.6 ± 2.2 -4.7 ± 7.4 LL02462

WB2C -13 -26 0 -0.4 ± 0.2 -0.2 ± 2.4 -8.6 ± 6.7 LL02463

WB3C -13 -30 0 -0.3 ± 0.2 -0.6 ± 1.8 51.2 ± 12.3 LL02464WB4C -8 59 0 -0.2 ± 0.2 1.5 ± 2.5 -2.4 ± 7.6 LL02465

WB5C -8 93 0 -0.4 ± 0.2 -0.6 ± 2.2 -6.1 ± 7.2 LL02466WB6C 7 -60 0 0.3 ± 1.2 -0.1 ± 2.0 -4.9 ± 7.0 LL02467WB7C -8 4 0 -0.2 ± 0.2 -0.3 ± 1.8 -6.1 ± 7.2 LL02468

WB8C -13 67 0 -0.4 ± 0.2 -0.6 ± 2.2 10.1 ± 9.1 LL02469WB9C 7 118 0 -0.3 ± 0.2 -0.1 ± 2.0 11.2 ± 9.1 LL02470WC1A -13 173 0 0.4 ± 1.2 -0.3 ± 1.8 -5.7 ± 7.4 LL02471WC2A -3 97 1 -0.4 ± 0.2 -0.2 ± 2.4 -5.1 ± 7.3 LL02472

WC3A -8 177 1 0.3 ± 1.2 1.3 ± 2.6 -0.1 ± 7.9 LL02473

WC4A 7 114 1 -0.2 ± 0.2 1.0 ± 2.3 -9.4 ± 7.0 LL02474WC5A 7 71 1 -0.4 ± 0.2 -2.9 ± 1.0 -13.1 ± 8.4 LL02475

WC6A -3 156 0 0.9 ± 1.7 0.3 ± 2.2 -3.0 ± 7.9 LL02476WC7A -8 143 1 0.4 ± 1.2 0.6 ± 2.2 -2.9 ± 7.6 LL02477

WC8A -8 33 1 -0.4 ± 0.2 -0.6 ± 2.2 -7.1 * 7.3 LL02478

WC1B -3 -17 1 -0.3 ± 0.2 0.8 ± 2.4 -4.6 ± 7.2 LL02479

C-9-2

Page 53: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2,--%H-4939-R-97, Facility Close-oui-ndTermination Surv, Camp. -lmer, NJ, 1 Jul - 20 Dec 97 I .

Camp Kilmer, BUILDING 1072 ROOM 7Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/100cm^2 dpml100cm^2 uR/hr dpm/1OOcmA2 +1-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.93 to 1.63 7.86 to 7.9(MDA>) 52 298 - .. 2 - 2.29 45.52 *WC2B -3 4 1 -0.2 ± 0.2 -0.3 ± 1.8 -3.9 ± 7.6 LL02480WC3B -8 12 0 -0.4 ± 0.2 -2.4 ± 1.4 -3.8 ± 7.5 LL02481WC4B -13 122 1 -0.3 ± 0.2 -0.6 ± 1.8 -3.9 ± 7.6 LL02482WC5B -3 29 1 -0.2 ± 0.2 -0.3 ± 1.8 -6.5 ± 7.1 LL02483WC6B 7 42 1 0.2 ± 1.2 -1.5 t 1.9 -5.1 ± 7.3 LL02484WC7B -8 38 1 -0.3 ± 0.2 -0.1 ± 2.0 -3.8 ± 7.5 LL02485WC8B -3 147 1 -0.2 ± 0.2 -0.7 ± 1.6 -4.1 ± 7.3 LL02486WC1C 2 169 1 0.2 ± 1.2 0.3 ± 2.6 -4.3 + 7.6 LL02487WC2C -3 71 0 -0.3 ± 0.2 0.3 ± 2.2 -3.8 ± 7.5 LL02488WC3C -3 186 0 0.4 ± 1.2 1.0 ± 2.3 -2.5- ± 8.0 LL02489WC4C 7 202 0 -0.4 ± 0.2 -2.0 ± 1.6 -2.9 ± 7.8 LL02490WC5C -3 202 0 -0.3 ± 0.2 -0.1 ± 2.0 -3.8 - ± 7.5 LL02491WC6C -8 97 1 0.1 ± 1.1 0.4 ± 2.7 -1.5 ± 7.9 LL02492WC7C -8 202 1 -0.4 ± 0.2 -0.2 ± 2.4 -7.8 ± 7.4 LL02493WC8C -13 139 1 -0.3 ± 0.2 0.8 ± 2.4 -5.7 ± 7.4 LL02494WD1A 2 164 1 -0.2 ± 0.2 1.9 ± 2.6 -2.9 ± 7.6 LL02495WD2A -13. 16 1 -0.4 ± 0.2 -1.1 ± 2.1 -3.3 ± ,7.5 LL02496WD3A -8 42" 1 0.9 ± 1.7 0.3 t 2.2 -2.8 ± 7.4 LL02497WD4A -3 -38 1 -0.2 ± 0.2 -0.7 ± 1.6 -7.9 ± 7.0 LL02498WDIB -3 33 1 -0.4 ± 0.2 -0.6 ± 2.2 -5.0 ± 7.2 LL02499WD2B -3 12 0 --0.3 ± 0.2 0.8 ± 2.4 -5.1 ± 7.3 LL02500WD3B -8 67 1 -0.2 ± 0.2 0.2 ± 2.0 -5.1 ± 7.3 LL02501WD4B -13 38 1 -0.4 ± 0.2 -0.2 ± 2.4 -2.5 ± 8.0 LL02502WD1C 2 93 .1 0.3 ± 1.2 -0.6 ± 1.8 -2.0 ± 7.7 LL02503WD2C 2 -17 1 -0.2 ±, 0.2 1.0 ± 2.3 -1.1 ± 8.2 LL02504WD3C -3 63 1 0.2 ± 1.2 -1.5 ± 1.9 -6.2 ± 7.4 LL02505WD4C 7 12 1 -0.3 ± 0.2 0.3 ± 2.2 -6.1 ± 7.2 LL02506WEIA 7 93 0 -0.2 ± 0.2 1.5 ± 2.5 -8.1 ± 7.1 LL02507WE2A -13 0 1 -0.4 ± 0.2 -2.0 ± 1.6 -4.7 ± 7.4 LL02508WE3A -3 152 1 -0.3 * 0.2 -0.1 ± 2.0 -6.7 ± 7.3 LL02509WE4A -13 16 1 -0.2 ± 0.2 1.9 ± 2.6 -3.8 ± .7.5 LL02510WEIB 7 21 1 -0.4 ± 0.2 -2.4 ± 1.4 -1.1 ± 8.2 LL02511WE2B 17 67 1 -0.3 ± 0.2 -1.0 ± 1.6 -0.6 * 7.8 LL02512WE3B -8 67 1 1.0 ± 1.7 0.2 ± 2.0 -3.9 ± 7.6 LL02513WE4B -8 97 1 -0.4 ± 0.2 -1.1 ± 2.1 -4.7 ± 7.4 LL02514WEIC -13 25 1 0.9 ± 1.7 -0.1 ± 2.0 -5.6 ± 7.3 LL02515WE2C 2 67 1 0.4 ± 1.2 1.0 ± 2.3 31.2 ± 10.8 LL02516WE3C 2 -5 1 -0.4 + 0.2 -0.6 ± 2.2 -2.9 ± 7.6 LL02517WE4C -8 55 0 0.3 ± 1.2 0.8 ± 2.4 0.8 ± 8.2 LL02518WF1A -8 8 1 0.4 ± 1.2 0.2 ± 2.0 -3.8 ± 7.5 LL02519WF2A -8 -34 0 -0.4 . 0.2 -2.4 ± 1.4 -6.5 ± 7.1. LL02520WVF3A -3 50 0 -0.3 ± 0.2 0.3 ± 2.2 0.8 ± 7.8 - LL02521WF4A -8 38 1 -0.2 ± 0.2 -0.7 ± 1.6 -2.9 ± 7.6 LL02522WF5A -13 71 0 -0.4 ± 0.2 0.3 ± 2.6 -5.6 ± 7.3 LL02523WF1B -3 101 1 0.3 ± 1.2 0.3 ± 2.2 -0.6 ± 7.8 LL02524WF2B 12 207 1 -0.2 ± 0.2 3.3 ± 3.0 -3.3 ± 7.5 LL02525WF3B -8 29 0 -0.4 ± 0.2 -1.5 ± 1.9 0.8 ± 8.2 LL02526WF4B -8 -60 1 0.3 ± 1.2 0.3 ± 2.2 2.6 + 8.2 LL02527-WF5B -8 93 0 0.4 ± 1.2 -0.7 ± 1.6 -2.9 ± 7.6 LL02528-WF1C -13 71 1 0.2 ± 1.2 -0.2 ± 2.4 -0.6 ± 7.8 LL02529

C-9-3

Page 54: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-out-andTermination Surv, Camp 'imer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 7

Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cmA2 dpnm/100cmA2 uRihr dpm/100cmn2 +1-2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.93 to 1.63 7.86 to 7.9

(MDA >) 52 298 - 2 2.29 45.52 *

WF2C -3 4 0 -0.3 + 0.2 -0.1 ± 2.0 -0.6 ± 8.0 LL02530

WF3C -3 101 0 -0.2 ± 0.2 0.2 ± 2.0 0.3 ± 7.8 LL02531

WF4C -8 80 1 -0.4 . 0.2 -2.0 ± 1.6 -2.9 ± 7.6 LL02532

VF5C -3 101 0 0.3 ± 1.2 2.2 ± 2.9 -3.9 ± 7.6 LL02533

Indicates the highest MDA for this survey unit. The Alpha MDAranged from 1.93 to 2 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.91 to 2.29 dpm

Indicates the highest MDA for this survey unit. The H-3 MDA ranged from 13.28 to 45.52 dpm

C-9-4

Page 55: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

( /1-

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 1072Room 8

WA WAIc Ic

AWA

WC 1Tc

ArA

BUILDING 1072. ROOM 8. CAMP KILMER, NEW JERSEY DATE* 20OCT97

DRAWN: MSD

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCALE: NTSUNITED STATES ARMY MEDICAL DEPARTMENT PLATE: N/A

C-10

Page 56: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-ot3 t andTermination Surv, Caml'"lmer, NJ, 1 Jul - 20 Dec 97 '

Camp Kilmer, BUILDING 1072 ROOM 8Location Monitoring . ..... Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/100cmA-2 dpm/lO0cm^2 uR/hr dpm/1OOcmA2 +/-2 sigma Number

(Bkgd=>) 5 0.1 to 0.33 0.93 to 1.48 7.86 to 7.9

(MDA>) 52 298 - 2 - 2.14 21.24 *

FA1 7 -44 1 -0.2 + 0.2 -0.7 + 1.6 -3.4 ± 9.0 LL02534FA2 -8 -302 1 1.4 ± 2.1 4.4 ± 3.7 -2.6 ± 8.2 LL02535FA3 -8 -44 0 2.7 ± 2.6 -0.6 t 1.8 -4.3 ± 8.4 LL02536FA4 -3 -247 0 1.6 ± 2.1 3.7 ± 3.2 -6.8 ± 8.1 LL02537FB1 2 -302 1 -0.4 ± 0.2 -1.1 ± 2.1 -4.6 ± 10.3 LL02538FB2 2 -340 1 -0.3 ± 0.2 1.3 ± 2.6 -4.7 ± 9.4 LL02539FB3 2 -158 1 -0.2 ± 0.2 -0.3 ± 1.8 0.4 ± 10.3 LL02540FB4 -3 -222 2 -0.4 ± 0.2 -1.1 ± 2.1 -1.7 ± 8.5 LL02541FC1 .- 8 -- 218 1 -0.3 ± 0.2 -1.5 ± 1.3 -13.1 ± 8.7 LL02542FC2 12 -277 1 -0.2 ± 0.2 0.6 ± 2.2 -6.5 ± 9.2 LL02543FC3 -3 -289 0 0.2 ± 1.2 -1.1 ± 2.1 -6.0 ± 10.5 LL02544FC4 12 -226 0 -0.3 ± 0.2 1.7 ± 2.7 -1.7 ± 8.9 LL02545FD1 -8 -251 0 -0.2 ± 0.2 1.0 ± 2.3 2.6 ± 9.9 LL02546FD2 -8 -133 0 0.8 ± 1.7 0.7 ± 2.7 -9.5 ± 10.5 LL02547FD3 2 -158 1 -0.3 ± 0.2 1.7 ± 2.7 -5.0 ± 10.0 LL02548FD4 -13 -95 1 0.4 ± 1.2 0.6 ± 2.2 -1.4 ± 10.4 LL02549FEl -13 -289 1 -0.4 ± 0.2 -1.5 ± 1.9 -4.4 ± 10.0 LL02550FE2 -3 ..-154 1 -0.3 ± 0.2 0.8 ± 2.4 -6.3 ± 8.2 LL02551FE3 -3 -175 0 -0.2 ± 0.2 0.2 ± 2.0 -2.8 ± 8.8 LL02552FE4 -3 -218 1 -0.4 ± 0.2 1.2 ± 2.9 -4.7 ± 9.4 LL02553QA NIA N/A NIA -0.3 ± 0.2 -0.1 ± 2.0 488.1 ± 30.2 LL02554

WAIA 2 8 0 -0.2 ± 0.2 -0.3 ± 1.8 -0.6 ± 7.8 LL02555WA2A -13 50 1 -0.4 ± 0.2 -2.4 ± 1.4 -5.4 ± 7.7 LL02556WA3A 2 59 1 -0.3 ± 0.2 0.3 ± 2.2 -4.7 ± 7.4 LL02557

WA4A 7 84 1 -0.2 ± 0.2 0.6 ± 2.2 -3.8 ± 7.5 LL02558WA1B -3 105 1 -0.4 ± 0.2 -0.2 ± 2.4 -8.1 ± 7.1 LL02559WA2B .2 143 0 -0.3 ± 0.2 1.3 ± 2.6 -7.6 ± 7.2 LL02560WA3B 12 21 0 -0.2 * 0.2 0.6 ± 2.2 -6.5 ± 7.1 LL02561WA4B 2 21 0 -0.4 * 0.2 -1.1 ± 2.1 -4.7 ± 7.4 LL02562WAIC 7 152 0 0.9 ± 1.7 0.3 ± 2.2 -0.1 ± 7.9 LL02563WA2C 7 63 1 -0.2 ± 0.2 0.2 ± 2.0 -2.5 ± 7.8 LL02564WA3C -8 71 1 -0.4 ± 0.2 -0.2 ± 2.4 -6.2 ± 7.4 LL02565

WA4C 17 55 1 -0.3 ± 0.2 2.2 ± 2.9 -2.5 ± 7.8 LL02566WB1A 7 16 1 -0.2 ± 0.2 -0.3 ± 1.8 -0.1 ± 8.1 LL02567WB2A 2 38 0 0.2 ± 1.2 -1.1 ± 2.1 -2.5 ± 7.8 LL02568WB3A 7 38 0 -0.3 ± 0.2 -1.0 ± 1.6 -7.4 ± 7.0 LL02569WB4A 23 59 1 0.4 ± 1.2 1.9 ± 2.6 -4.2 ± 7.4 LL02570WB5A -8 -38 1 -0.4 ± 0.2 -0.2 ± 2.4 -4.3 ± 7.6 LL02571WBIB 2 25 1 -0.3 ± 0.2 0.8 t 2.4 0.8 ± 8.0 LL02572WB2B -3 46 0 -0.2 ± 0.2 0.6 ± 2.2 -5.7 ± 7.4 LL02573WB3B -3 101 0 0.8 ± 1.7 -1.1 ± 2.1 -3.9 ± 7.6 LL02574WB4B -13 50 0 0.3 ± 1.2 -1.0 ± 1.6 -3.8 ± 7.5 LL02575WB5B -3 -38 0 -0.2 ± 0.2 -0.3 ± 1.8 -4.2 ± 7.4 LL02576WB1C -8 29 1 -0.4 ± 0.2 -1.1 ± 2.1 -2.9 ± 7.6 LL02577WB2C 2 25 1 -0.3 ± 0.2 -0.6 ± 1.8 -2.5 ± 7.8 LL02578WB3C 2 97 1 -0.2 ± 0.2 -0.3 ± 1.8 -7.0 ± 7.1 LL02579WB4C 2 97 0 -0.4 ± 0.2 -2.4 ± 1.4 -5.2 ± 6.8 LL02580WB5C -8 12 1 -0.3 ± 0.2 -0.1 ± 2.0 -0.6 ± 7.8 LL02581

WCIA 2 84 0 -0.2 ± 0.2 0.6 ± 2.2 -4.7 ± 7.4 LL02582WC2A 17 164 0 -0.4 ± 0.2 -1.1 ± 2.1 -6.1 ± 7.2 LL02583

C-10-1

Page 57: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2--MH-4939-R-97, Facility Close-or- -ndTermination Surv, Camp .. lmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 8Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha .Beta LS Wipe

(Units =>) dpmrl100cmA2 dpmlO00cmA2 uRlhr dpmlO00cmA2 21- 2sigma Number

(Bkgd=>) 5 0.1 to 0.33 0.93 to 1.48 7.86 to 7.9(MDA>) 52 298 - 2 2.14 " 21.24 " _

WC3A -8 135 0 0.3 + 1.2 -0.1 t 2.0 -7.0 * 7.1 LL02584WC4A -8 29 0 -0.2 + 0.2 0.2 t 2.0 -4.2 * 7.4 LL02585WCIB -8 80 0 -0.4 ± 0.2 2.5 ± 3.3 1.2 ± 8.0 LL02586WC2B 7 139 0 -0.3 ± 0.2 1.3 ± 2.6 -4.2 ± 7.4 LL02587WC3B -8 -13 1 0.4 ± 1.2 0.2 ± 2.0 -6.2 ± 6.8 LL02588WC4B -13 80 0 0.2 ± 1.2 -1.1 * 2.1 -5.3 ± 7.5 LL02589WC1C -8 63 1 0.3 ± 1.2 -0.1 ± 2.0 -4.2 ± 7.4 LL02590WC2C 12 105 1 0.4 ± 1.2 -0.3 ± 1.8 -2.5 ± 7.8 LL02591WC3C -8 12 1 -0.4 + 0.2 -0.2 ± 2.4 -1.5 ± 7.7 LL02592WC4C 2 33 1 -0.3 ± 0.2 0.3 ± 2.2 -4.8 ± 7.5 LL02593WDIA -8 46 1 -0.2 ± 0.2 -1.2 ± 1.3 -7.1 ± 7.3 LL02594WD2A 2 33 1 -0.4 ± 0.2 0.3 ± 2.6 2.1 ± 8.1 LL02595WD3A -3 202 1 -0.3 ± 0.2 0.8 ± 2.4 -3.3 ± 7.5 LL02596WD4A 17 29 1 -0.2 ± 0.2 1.9 ± 2.6 -3.4 ± 7.7 LL02597WD5A 2 -17 1 -0.4 ± 0.2 0.3 ± 2.6 -0.1 ± 7.9 LL02598WD1B -8 -13 1 -0.3 ± 0.2 0.8 ± 2.4 -9.0 ± 7.0 LL02599WD2B -8 143 1 -0.2 ± 0.2 -1.2 ±• 1.3 -1.5 ± 7.7 LL02600WD3B 7 55. 1 -0.4 ± 0.2 -2.0 ± 1.6 -3.4 ± 7.7 LL02601WD4B -8 42 1 -0.3 ± 0.2 0.8 ± 2.4 -2.3 l 7.3 LL02602WVD5B -3 122 0 -0.2 ± 0.2 -0.3 ± 1.8 -1.5 ± 7.6 LL02603WD1C -3 50 1 -0.4 ± 0.2 -1.1 ± 2.1 -8.1 ± 6.8 LL02604WD2C -3 38 1 0.3 ± 1.2 -1.0 ± 1.6 -7.4 ± 7.0 LL02605WD3C 7 245 0 -0.2 ± 0.2 1.5 ± 2.5 -2.9 ± 7.6 LL02606WD4C 12 219 0 0.2 ± 1.2 -1.1 ± 2.1 -1.1 ± 7.8 LL02607WD5C 7 80 0 0.3 ± 1.2 1.3 ± 2.6 -3.8 ± 7.5 LL02608

Indicates the highest MDA for this survey unit. The Alpha MDA ranged from 1.93 to 2 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.91 to 2.14 dpm

Indicates the highest MDA for this survey unit. The H-3B MDA ranged from 13.56 to 21.24 dpm

C-10-2

Page 58: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

2)

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

C-II

Page 59: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2C-MH-4939-R-97, Facility Close-o10-2 andTermination Surv, Can, )ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cmA2 dpmnlOOcMAn2 uRlhr - dpmn/IOOcmA2 +/-2_sigma Number

(Bkgd >) 5 0.0 to 0.34, 0.89 to 1.41 7.86 to 7.9

(MDA =>) 52 284 - 2.44 2.39 * 49.02 "

FA1 -8 143 0 0.0 ± 0.1 0.2 ± 2.5 -5.9 ± 9.3 LL00001

FA2 12 179 0 0.0 ± 0.1 2.4 ± 3.3 0.5 ± 12.0 LL00002FA3 7 111 0 0.0 ± 0.1 1.3 ± 2.9 -4.9 ± 9.7 LL00003

FA4 -13 107 0 0.7 ± 1.5 -0.3 ± 2.2 -7.6 ±. 12.0 LL00004

FA5 2 135 0 0.0 ± 0.1 0.8 ± 2.7 -3.9 ± 12.4 LL00005

FA6 2 14 0 1.5 ± 2.2 1.3 ± 2.9 -3.0 ± 9.6 LL00006FA7 2 179 0 0.0 ± 0.1 0.8 ± 2.7 -4.3 ± 9.7 LL00007FA8 2 79 0 0.7 ± 1.5 1.9 ± 3.1 -3.9 ± 10.4 LL00008FA9 -8 -62 0 0.0 ± 0.1 3.0 ± 3.5 -6.2 ± 10.9 LL00009

FA10 -3 -46 0 0.0 ± 0.1 1.9 ± 3.1 -5.4 ± 10.6 LL00010

FAll -13 95 0 0.7 ± 1.5 2.4 ± 3.3 -13.1 ± 10.9 LL00011

FA12 -13 -34 0 0.7 ± 1.5 0.8 ± 2.7 -4.2 ± 11.1 LL00012FA13 7 2 0 0.7 ± 1.5 2.4 ± 3.3 -16.1 .± 16.4 LL00013

FA14 -3 -2 -1 0.7 ± 1.5 0.8 ± 2.7 -8.8 ± 11.4 LL00014

FA15 -3 -18 -1 0.0 ± 0.1 0.8 ± 2.7 -12.2 ± 10.2 LL00015FA16 2 22 -1 0.0 ± 0.1 0.8 ± 2.7 -8.1 ± 11.5 LL00016FA17 . -3 91 0 0.0 ± 0.1 -0.3 ± 2.2 -5.5 ± 11.0 LL00017

FA18 2 79. 0 0.7 ± 1.5 0.8 ± 2.7 -5.6 ± 12.7 LL00018FA19 2 -26 0 0.7 ± 1.5 3.0 ± 3.5 -4.2 ± 11.1 LL00019

FA20 2 -30 0 0.0 ± 0.1 2.4 ± 3.3 -7.8 ± 11.1 LL00020

FA21 -3 111 0 0.7 ± .1.5 1.9 ± 3.1 -9.9 ± 11.7 LL00021FA22 -13 183 0 0.0 ± 0.1 -0.9 ± 2.0 -21.2 ± 14.0 LL00022

FA23 7 34 0 0.0 ± 0.1 0.8 ± 2.7 -11.9 ± 10.6 LL00023

FA24 -8 58 -1 0.7 ± 1.5 0.2 ± 2.5 -5.7 ± 11.3 LL00024

FA25 -8 107 -1 0.0 ± 0.1 2.4 ± 3.3 -12.5 ± 11.9 LL00025

FA26 2 199 0 0.7 ± 1.5 .0.8 ± 2.7 -6.6 ± 13.2 LL00026

FA27 7 -34 0 0.0 ± 0.1 1.9 ± 3.1 -10.3 ± 13.3 LL00027

FA28 2 95 0 0.0 ± 0.1 -0.3 ± 2.2. -25.7 ± 12.6 LL00028

FA29 -3 -127 -1 0.0 ± 0.1 4.7 ± 3.9 -11.3 ± 16.1 LL00029

FA30 -8 66 -1 0.0 ± 0.1 1.3 ± 2.9 -17.8 ± 11.8 LL00030FA31 -3 143 -1 0.7 ± 1.5 .1.9 ± 3.1 -9.9 ± 11.7 LL00031

FA32 2 123 0 0.0 ± 0.1 -0.3 ± 2.2 -10.6 ± .11.6 LL00032

FA33 2 175 -1 0.0 ± 0.1 1.3 ± 2.9 -11.9 ± 10.6 LL00033

FA34 -3 111 0 0.0 ± 0.1 -1.4 ± 1.6 -4.2 ± 11.1 LL00034

FA35 -8 143 0 0.0 ± 0.1 3.5 ± 3.6 -9.3 ± 9.4 LL00035

FA36 -8 91 0 0.0 ± 0.1 -0.3 ± 2.2 -5.5 ± 9.6 LL00036'

FA37 -13 175 0 0.0 ± 0.1 -0.9 ± 2.0 -10.5 ± 9.3 LL00037

FA38 7 99 0 0.7 ± 1.5 2.4 ± 3.3 -5.5 ± 9.6 LL00038

FA39 -3 46 0 0.0 ± 0.1 1.9 ± 3.1 -11.5 ± 10.2 LL00039FA40 -8 42 0 0.0 ± 0.1 1.3 ± 2.9 -4.6 ± 10.3 LLODO40

FA41 -3 -6 0 0.0 ± 0.1 2.4 ± 3.3 -9.9 ± 9.4 LLOOD41

FA42 28 115 0 0.0 ± 0.1 .- 1.3 ± 2.9 -1.4 ± 10.7 LL00042

FA43 2 87 0 0.0 ± 0.1 1.3 ± 2.9 -9.6 ± 9.8 LL00043

FA44 -8 135 0 0.7 ± 1.5 1.3 ± 2.9 -6.7 ± 9.5 LL00044

FA45 -3 131 0 0.7 ± 1.5 -0.3 ± 2.2 -8.2 ± 10.6 LL00045FA46 2 66 -1 0.5 ± 1.2 1.5 ± 2.4 -1.9 ± 9.7 LL00046

FA47 -3 26 -1 -0.1 ± 0.1 0.2 ± 1.9 -5.5 ± 9.6 LL00047

FA48 -8 107 0 1.1 ± 1.6 -0.2 ± 1.7 -10.8 ± 9.6 LL00048

FA49 -3 199 0 -0.1 ± 0.1 2.8 ± 2.8 -5.2 ± 11.8 LL00049

FA50 -8 42 0 -0.1 ± 0.1 0.2 ± 1.9 -6.2 ± 9.8 LL00050

C-11-1

Page 60: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-out-andTermination Surv, Camp' ')lmer, NJ, 1 Jul - 20 Dec 97 /

Camn Kilmer RUlLflIN~ 1072 ROOM 9 ----- I-.

Location Monitoring Wipe TestCode Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/lODcmA2 dpm/100cm^2 uRihr dprrdlODcmn2 +/-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

MDA >) 52 284 - 2.44 2.39 49.02 * ," I -

FB1 12 54 0 0.5 ± 1.2 1.9 + 2.6 -4.6 ± 9.1 LL00051

FB2 -8 127 1 1.1 ± 1.6 0.6 ± 2.1 -11.9 + 10.6 LL00052

FB3 -3 79 1 1.1 ± 1.6 0.2 + 1.9 -10.2 ± 10.4 LL00053

FFB4 -8 71 0 -0.1 ± 0.1 0.2 ± 1.9 -5.4 ± 10.6 LL00054

FB5 -3 95 0 0.5 ± 1.2 2.3 ± 2.7 -9.2 ± 10.1 LL00055FB6 -3 50 1 -0.1 + 0.1 3.2 ± 2.9 -4.6 ± 10.3 LL00056

FB7 -8 54 0 0.5 4 1.2 -0.2 ± 1.7 -12.9 ± 10.1 LL00057

F88 -8 111 0 0.5 ± 1.2 0.2 ± 1.9 -4.6 ± 10.3 LL00058

FB9 -8 87 0 1.1 * 1.6 3.2 ± 2.9 -6.0 ± 10.5 LL00059

FBIO -3 2 0 1.7 ± 2.0 1.9 ± 2.6 -5.2 ± 10.3 LLO0060FB11 17 87.. 0 1.7 * 2.0 3.6 ± 3.1 -10.5 + 10.0 LLO0061

FB12 -3 87 1 -0.1 :t 0.1 0.6 ± 2.1 -4.5 ± 8.9 LL00062

FB13 -3 66 0 0.5 * 1.2 2.3 ± 2.7 -6.2 ± 12.2 LL00063

FB14 2 42 0 0.5 *t 1.2 2.3 ± 2.7 -12.8 ± 11.4 LL00064

FB15 2 107 0 -0.1 * 0.1 2.3 ± 2.7 -9.1 ± 11.8 LL00065

FB16 -8 171 0 1.7 ± 2,0 1.9 ± 2.6 -14.3 ± 11.2 LL00066

FB17 12 95 0- -0.1 ± 0.1 2.3 ± 2.7 -8.4 ± 11.9 LL00067

FB18 -13 46" 0 1.1 * 1.6 -0.7 ± 1.5 -12.2 ± 10.2 LLO0068

FB19 2 -30 0 1.1 ± 1.6 0.2 ± 1.9 -7.1 ± 10.1 LL00069

FB20 -3 46 0 -0.1 ± 0.1 2.8 ± 2.8 -17.9 ± 11.2 LLO0070

FB21 7 -2 0 -0.1 ± 0.1 1.1 ± 2.3 -14.0 ± 10.3 LLO0071

FB22 2 119 0 1.7 ± 2.0 -0.7 ± 1.5 -11.0 ± 12.1 LL00072

FB23 -3, 95 0 -0.1 ± 0.1 1.5 ± 2.4 -7.8 ± 11.1 LL00073

FB24 -13 127 0 -0.1 ± 0.1 0.2 ± 1.9 -11.5 ± 10.2 LL00074

FB25 -13 34 0 -0.1 ± 0.1 1.9 ± 2.6 -9.5 ± 10.5 LLO0075

FB26 -8 79 0 0.5 ±' 1.2 1.1 ± 2.3 -18.5 ± 12.9 LL00076

FB27 -13 95 0 -0.1 ± 0.1 -0.7 ± 1.5 -12.8 ± 11.4 LL00077

FB28 2 58 0 1.1 ± 1.6 0.2 ± 1.9 -16.9 ± 12.5 LL00078

FB29 2 62 -1 1.1 ± 1.6 -0.2 ± 1.7 -15.0 + 11.1 LL00079

FB30 -8 -22 -1 1.1 ± 1.6 1.1 ± 2.3 -18.0 ± 10.7 LLO0080

rFB31 -3 -34 -1 0.5 ±, 1.2 1.5 ± 2.4 -15.2 ± 10.6 LL00081FB32 -13 151 -1 -0.1 ± 0.1 -0.2 ± 1.7 -14.9 ± 11.6 LL00082

FB33 -8 46 0 -0.1 ± 0.1 1.1 ± 2.3 -3.0 ± 11.7 LL00083

FB34 12 195 0 1.1 ± 1.6 1.1 ± 2.3 -12.4 ± 11.0 LL00084

FB35 2 155 0 -0.1 ± 0.1 1.9 ± 2.6 -7.5 ± 10.7 LLO0085FB36 -8 216 0 0.5 ± 1.2 0.2 ± 1.9 3.0 t 11.5 LL00086

FB37 -8 123 0 1.7 ± 2.0 1.1 ± 2.3 -10.8 ± 9.6 LLO0087

FB38 12 103 0 -0.1 ± 0.1 0.2 ± 1.9 -8.1 ± 9.6 LL00088

FB39 -3 79 0 3.5 ± 2.9 3.6 t 3.1 -6.2 ± 9.8 LL00089

FB40 7 46 0 -0.1 ± 0.1 -0.2 ± 1.7 -6.9 ± 9.7 LLO0090

FB41 .3 171 0 -0.1 ± 0.1 -0.2 ± 1.7 -8.2 * 9.0 LL00091

FB42 2 -10 0 0.5 ± 1.2 -0.2 ± 1.7 1.0 ± 10.3 LL00092

FB43 -8 127 0 3.5 * 2.9 12.6 ± 4.9 -3.1 ± 9.9 LL00093

FB44 -13 -42 0 -0.1 ± 0.1 1.9 ± 2.6 -3.3 ± 10.5 LL00094

FB45 -8 127 0 0.5 ± 1.2 1.9 ± 2.6 -8.2 ± 10.6 LL00095

FB46 -3 131 0 0.5 :t 1.2 0.6 ± 2.1 -16.2 ± 12.0 LL00096

FB47 -8 111 1 0.5 ± 1.2 -0.2 ± 1.7 -10.6 ± 10.8 LL00097

FB48 7 71 0 -0.1 ± 0.1 3.2 ± 2.9 -10.3 ± 13.3 LL00098

FB49 2 139 0 -0.1 ± 0.1 2.3 ± 2.7 -1.0 ± 12.8 LL00099

FB50 2 147 0 1.1 ± 1.6 -0.2 ± 1.7 -5.4 ± 10.6 ILLO0100

C-1i1-2

Page 61: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. '.-"MH-4939-R-97, Facility Close-o-7andTermination Surv, Camp .ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units =>) dpm1OOcmA2 dpm1l00cmA2 uRPhr dpmlO00ccmA2 +1-2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9(MDA =>) 52 284 - 2.44" 2.39 * 49.02 *QA NIA N/A N/A -0.1 * 0.1 0.2 ± 1.9 -1.2 ± 8.6 LL00101FC1 2 155 1 -0.1 ± 0.1 1.1 ± 2.3 -1.8 ± 9.2 LL00102FC2 7 -26 1 1.7 ± 2.0 1.5 ± 2.4 -9.6 ± 8.5 LL00103FC3 -3 175 1 -0.1 ± 0.1 0.6 ± 2.1 -3.1 ± 9.9 LL00104FC4 2 83 1 0.5 ± 1.2 1.1 ± 2.3 -0.7 ± 9.6 LL00105FC5 2 87 0 -0.1 ± 0.1 -0.2 ± 1.7 -5.6 ± 9.9 LL00106FC6 -8 75 1 1.1 * 1.6 1.5 ± 2.4 -7.1 ± 10.1 LL00107FC7 -13 10 0 0.5 ± 1.2 0.6 ± 2.1 -4.2 ± 9.5 LL00108FC8 2 34 0 -0.1 + 0.1 3.2 ± 2.9 -9.6 ± 9.8 LL00109FC9 -8 -2 1 -0.1 ± 0.1 2.8 ± 2.8 -8.3 + 9.9 LL00110FC10 17 -75 -0 0.5 ± 1.2 1.1 ± 2.3 -9.9 ± 10.8 LL0011IFC11 -8 62 0 -0.1 ± 0.1 0.2 ± 1.9 -6.1 ± 9.5 LL00112FC12 2 191 0 -0.1 ± 0.1 -0.2 ± 1.7 -4.1 ± 9.2 LL00113FC13 -3 14 0 -0.1 ± 0.1 1.1 ± 2.3 -10.5 ± 10.0 LL00114FC14 -8 30 0 -0.1 ± 0.1 -0.7 ± 1.5 -8.1 ± 11.5 LL00115FC15 2 14 0 0.5 ± 1.2 1.1 ± 2.3 -11.6 ± 11.1 LL00116FC16 -13 151 -1 -0.1 ± 0.1 1.9 ± 2.6 -13.6 ± 12.9 LL00117FC17 -8 42' 0 0.5 ± 1.2 -0.7 ± 1.5 -7.2 ±. 14.3 LL00118FC18 -13 71 0 0.5 ± 1.2 1.1 ± 2.3 -10.6 ± 11.6 LL00119FC19 2 79 0 -0.1 ± 0.1 0.6 ± 2.1 -9.4 ± 13.4 LL00120FC20 2 26 0 0.5 ± 1.2 -1.1 ± 1.3 -6.2 ± 10.9 LL00121FC21 -3 111 -1 -0.1 ± 0.1 -0.2 ± 1.7 -4.2 ± 13.4 LL00122FC22 -13 62 -1 1.7 ± 2.0 1.9 ± 2.6 -8.2 ± 10.6 LL00123FC23 -3 87 0 0.5 ± 1.2 1.1 ± 2.3 -5.7 ± 11.3 LL00124FC24 2 151 0 1.7 ±. 2.0 1.1 ± 2.3 A12.8 ± 11.4 LL00125FC25 -13 -30 0 0.5 ± 1.2 0.6 ± 2.1 -11.2 ± 10.7 LL00126FC26 17 6 0 -0.1 ± 0.1 0.6 ± 2.1 -13.6 ± 11.3 LL00127FC27 7 34 0 1.1 ± 1.6 0.2 ± 1.9 -18.5 ± 13.6 LL00128FC28 -3 79 0 0.5 ± 1.2 -0.7 ± 1.5 -9.1 1 11.8 LL00129FC29 2 -14 0 0.5 ± 1.2 -0.2 ± 1.7 -17.0 * 11.9 LL00130FC30 -8 155 0 -0.1 ± 0.1 -0.2 ± 1.7 -9.4 * 13.4 LL00131FC31 7 103 0 -0.1 ± 0.1 1.9 ± 2.6 -8.4 ± 14.8 LL00132FC32 7 131 0. -0.1 ± 0.1 0.2 ± 1.9 -19.3 ± 15.1 LL00133FC33 -3 264 0 1.7 ± 2.0 0.6 ± 2.1 -8.1 ± 11.5 LL00134FC34 -3 143 0 0.5 ± 1.2 2.3 ± 2.7 -13.8 ± 10.8 LL00135FC35 -8 244 0 1.7 ± 2.0 -1.1 ± 1.3 -8.5 ± 11.0 LL00136FC36 -8 147 0 -0.1 ± 0.1 -0.2 ± 1.7 -10.2 ± 11.2 LL00137FC37 -3 30 0 0.5 ± 1.2 1.1 ± 2.3 -8.1 ± 11.5 LL00138FC38 -3 -66 0 0.5 ± 1.2 3.2 ± 2.9 -10.2 ± 9.7 LL00139FC39 -8 195 1 1.1 ± 1.6 2.3 ± 2.7 -7.9 ± 10.3 LL00140FC40 -13 71 0 0.3 ± 1.3 -2.2 ± 1.1 -2.0 ± 10.3 LL00141FC41 2 183 0 -0.4 ± 0.2 0.9 ± 2.7 -4.9 ± 9.7 LL00142FC42 -8 83 0 -0.4 ± 0.2 0.9 ± 2.7 -2.9 ± 9.3 LL00143FC43 -3 54 1 -0.4 ± 0.2 7.9 ± 4.6 -0.7 ± 9.9 LL00144FC44 -8 123 0 -0.4 ± 0.2 0.9 ± 2.7 4.1 ± 11.0 LL00145FC45 2 99 0 -0.4 ± 0.2 1.4 ± 2.8 -2.5 ± 9.9 LL00146FC46 -3 143 1 -0.4 ± 0.2 0.9 ± 2.7 -8.1 ± 11.5 LL00147FC47 7 211 1 0.3 ± 1.3 1.4 ± 2.8 -16.2 ± 9.6 LL00148FC48 2 107 1 -0.4 ± 0.2 0.9 ± 2.7 -9.5 ± 10.5 LL00149FC49 -13 107 1 0.3 ± 1.3 2.4 ± 3.2 -11.7 ± 9.2 LL00150

C-11-3

Page 62: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27KilMH-4939-R-97, Facility Close-out-andTermination Surv, Camp \ý.mer,-NJ, 1 Jul -20 Dec 97

CamD3 Kilmer. BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cm^2 dpmrl00cm^2 uRlhr dpm/I00cmA2 +/-2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA=>) 52 284 - 2.44 2.39 " 49.02 "

FC50 12 83 0 0.3 + 1.3 0.9 t 2.7 -6.0 ± 10.5 LL00151FD1 7 224 0 -0.4 ± 0.2 -0.2 t 2.3 0.4 ± 9.2 LL00152FD2 23 199 0 -0.4 ± 0.2 0.4 t 2.5 -7.2 ± 8.6 LL00153FD3 -8 38 1 -0.4 t 0.2 1.9 t 3.0 3.7 t 10.1 LL00154FD4 -8 155 0 -0.4 t 0.2 0.9 t 2.7 -1.9 + 10.0 LL00155FD5 2 151 0 0.3 ± 1.3 1.4 ± 2.8 -3.2 ± 8.6 LL00156FD6 -8 26 0 -0.4 ± 0.2 1.9 t 3.0 -1.2 ± 9.3 LL00157FD7 2 95 0 1.6 * 2.2 4.9 t 3.9 -9.7 ± 7.6 LL0015BFD8 -13 6 0 -0.4 t 0.2 2.4 t 3.2 -1.9 ± 9.7 LL00159FD9 -8 -42 0 -0.3 * 0.2 0.2 ± 2.5 -4.2 ± 9.5 LL00160FD10 -3 83 1 0.3 ± 1.3 1.4 ± 2.8 -2.4 ± 9.4 LL00161FD11 -8 34 0 -0.4 ± 0.2 0.9 ± 2.7 -3.5 ± 9.3 LL00162-FD12 12 58 0 -0.4 ± 0.2 0.9 ± 2.7 -16.4 ± 8.9 LL00163FD13 7 10 0 2.2 ± 2.6 0.9 ± 2.7 -11.6 ± 11.1 LL00164FD14 -3 30 0 -0.4 ± 0.2 3.4 ± 3.5 -8.5 ± 11.0 LL00165FD15 -8 -119 0 0.9 ± 1.8 1.9 ± 3.0 -16.9 ± 10.9 LL00166FD16 -8 6 0 -0.4 ± 0.2 -1.2 ± 1.8 -15.0 ± 9.4 LL00167FD17 -3 46 0 -0.4 ± 0.2 1.9 ± 3.0 -4.5 ± 11.9 LL00168FD18 -13 -127 0 -0.4 ± 0.2 2.4 ± 3.2 -2.7 ± 10.6 LL00169FD19 -8 107 0 -0.4 ± 0.2 2.4 ± 3.2 -12.2 ± 10.2 LL00170FD20 -13 95 0 -0.4 ± 0.2 0.4 ± 2.5 -4.7 ± 10.7 LL00171FD21 12 -10 0 -0.4 ± 0.2 4'4 ± 3.7 -5.9 ± 11.7 LL00172FD22 -13 71 0 -0.4 ± 0.2 1.4 ± 2.8 -6.9 ± 10.8 LL00173FD23 7 50 0 -0.4 ± 0.2 1.9 ± 3.0 -4.9 ± 11.0 LL00174FD24 2 83 0 -0.4 ± 0.2 -1.7 ± 1.5 -9.2 ± 10.9 LL00175FD25 2 123 0 0.9 ± 1.8 0.4 t 2.5 -9.5 ± 12.3 LL00176FD26 7 50 0 -0.4 ± 0.2 2.4 t 3.2 -8.4 t 11.9 LL00177FD27 33 26 -1 -0.4 ± 0.2 0.4 * 2.5 -7.8 ± 11.1 LL00178.FD28 2 99 -1 0.3 ± 1.3 2.4 ± 3.2 -8.5 ± 11.0 LL00179FD29 2 -79 -1 0.3 ± 1.3 2.4 ± 3.2 -12.6 ± 10.5 LL00180FD30 -13 127 0 -0.4 ± 0.2 1.9 * 3.0 -9.1 ± 11.8 LL00181FD31 -8 -26 0 0.3 ± 1.3 -0.2 ± 2.3 -14.6 t 12.2 LL00182FD32 7 2 0 0.3 ± 1.3 -0.7 ± 2.0 -12.1 ± 14.4 LL00183

FD33 2 236 0 -0.4 * 0.2 0.9 ± 2.7 -9.5 ± 11.3 LL00184FD34 7 179 0 -0.4 ± 0.2 0.4 :± 2.5 -10.9 ± 11.1 LL00185FD35 -3 179 0 0.3 ± 1.3 1.4 ± 2.8 -11.4 ± 12.6 LL00186FD36 -3 -14 0 -0.4 ± 0.2 0.9 ± 2.7 -13.0 t 14.3 LL00187FD37 17 163 0 1.6 ± 2.2 4.4 ± 3.7 -4.9 ± 11.0 LL00188FD38 2 95 1 -0.4 ± 0.2 -1.2 ± 1.8 -1.5 ± 11.4 LL00189FD39 -3 127 0 0.3 ± 1.3 3.9 ± 3.6 -6.0 ± 10.5 LLOO190FD40 -3 10 0 -0.4 ± 0.2 0.9 ± 2.7 -5.8 ± 10.2 LL00191FD41 -3 123 0 0.3 t 1.3 0.4 ± 2.5 -3.0 ± 11.7 LL00192FD42 -3 107 1 0.9 ± 1.8 -0.2 ± 2.3 -5.2 ± 10.3 LL00193FD43 12 111 0 0.9 ± 1.8 -0.2 ± 2.3 -1.9 ± 9.7 LL00194FD44 -13 103 0 -0.4 ± 0.2 -0.7 ± 2.0 -7.3 ± 10.4 LL00195FD45 2 135 0 -0.4 ± 0.2 -0.7 ± 2.0 -1.6 ± 11.8 LL00196FD46 -13 79 0 -0.4 ± 0.2 -0.2 ± 2.3 -0.8 ± 11.1 LL00197FD47 2 147 0 -0.4 ± 0.2 -0.7 t 2.0 -16.4 ± 11.4 LL00198F048 2 216 0 -0.4 ± 0.2 0.4 ± 2.5 -7.8 ± 11.1 LL00199FD49 2 . 163 -1 -0.4 ± 0.2 0.9 ± 2.7 -3.9 ± 10.4 LL00200

C-11-4

Page 63: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. '-MH-4939-R-97, Facility Close--'-- andTermination Surv, Can%, Kilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/lOOcmA2 dpm/1OOcmA2 uRlhr dpmnlOOcmA2 +1-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9(MDA>) 52 284 - 2.44 " 2.39 " 49.02 *FD50 -3 183 0 0.3 + 1.3 2.4 ± 3.2 -2.5 ± 13.1 LL00201QA N/A N/A N/A 0.3 ± 1.3 0.4 + 2.5 978.4 ± 44.2 LL00202FE1 2 87 1 -0.4 t 0.2 1.9 t 3.0 -2.6 ± 8.2 LL00203FE2 -8 30 1 0.9 ± 1.8 -1.7 t 1.5 -4.9 t 8.6 LL00204FE3 17 216 1 -0.4 ± 0.2 -0.7 ± 2.0 -6.0 ± 7.8 LL00205FE4 -3 -46 1 -0.4 * 0.2 -0.2 + 2.3 -0.6 t 8.2 LL00206FE5 -8 22 0 0.3 ± 1.3 1.4 ± 2.8 -8.4 ± 7.9 LL00207FE6 17 58 0 -0.4 ± 0.2 2.4 t 3.2 -3.7 ± 8.3 LL00208FE7 2 -6 1 -0.4 ± 0.2 0.9 ±' 2.7 -5.3 ± 7.5 LL00209FE8 7 -58 1 0.9 t 1.8 0.4 t 2.5 -3.4 ± 7.7 LL00210FE9 17 66 0 1.6 ± 2.2 3.9 t 3.6 -2.1 ± 8.1 LL00211FE10 .7 -38 1 -0.4 ± 0.2 -0.7 ± 2.0 -1.1 ± 7.8 LL00212FEll 7 50 0 -0.4 ± 0.2 1.4 ± 2.8 -1.5 ± 7.7 LL00213FE12 12 22 0 -0.4 ± 0.2 0.9 + 2.7 -4.7 ± 8.2 LL00214FE13 -8 107 0 -0.4 t 0.2 -0.2 ± 2.3 8.3 ± 11.4 LL00215FE14 -3 14 0 -0.4 + 0.2 -0.7 * 2.0 -2.5 t 9.9 LL00216FE15 -3 .18 0 -0.4 ± 0.2 1.9 ± 3.0 -3.9 ± 10.4 LL00217FE16 -8 46' 0 0.3 ± 1.3 1.9 ± 3.0 -11.8 ± 8.2 LL00218FE17 7 111 0 0.3 ± 1.3 0.4 ± 2.5 -4.5 ± 8.9 LL00219FEIB 7 -42 0 -0.4 ± 0.2 0.9 ± 2.7 -10.2 ± 8.5 LL00220FE19 12 34 0 0.3 ± 1.3 -0.2 ± 2.3 1.0 ± 10.0 LL00221FE20 -3 75 0 0.3 ± 1.3 0.9 ± 2.7 -9.6 ± 9.1 LL00222FE21 2 -6 0 -0.4 + 0.2 -0.7 ± 2.0 -7.7. ± 8.5 LL00223FE22 7 6 0 -0.4 ± 0.2 2.4 ± 3.2 -4.2 ± 9.5 LL00224FE23 12 10 0 -0.4 ±. 0.2 0.4 ± 2.5 -4.6 ± 9.1 LL00225FE24 12 -6 0 -0.2 ± 0.2 -0.1 ± 2.2 -2.1 ± 11.0 LL00226FE25 2 58 0 0.3 ± 1.3 0.4 ± 2.5 -9.9 ± 8.8 LL00227FE26 -8 14 0 0.3 ± 1.3 1.4 ± 2.8 -9.9 ± 10.1 LL00228FE27 2 -75 0 -0.4 + 0.2 0.4 ± 2.5 -7.5 ± 10.7 LL00229FE28 7 46 0 -0.4 ± 0.2 0.9 ± 2.7 -10.5 ± 10.0 LL00230FE29 17 135 0 -0.4 * 0.2 0.4 ± 2.5 -12.1 ± 9.4 LL00231FE30 2 71 0 -0.4 ± 0.2 3.9 ± 3.6 -12.2 ± 10.2 LL00232FE31 7 123 0 -0.4 * 0.2 2.4 ± 3.2 -13.1 ± 9.7 LL00233FE32 2 107 0 0.3 ± 1.3 0.9 ± 2.7 -13.1 ± 9.7 LL00234FE33 7 127 0 0.9 ± 1.8 -0.7 ± 2.0 -6.3 ± 8.9 LL00235FE34 -3 -50 0 0.3 ± 1.3 0.9 ± 2.7 -6.5 ± 9.2 LL00236FE35 7 54 -1 0.9 ± 1.8 1.9 ± 3.0 -5.0 ± 10.0 LL00237FE36 7 22 0 0.4 ± 1.2 -1.0 ± 1.8 -8.7 ± 8.9 LL00238FE37 7 115 0 0.4 ± 1.2 -0.5 ± 1.8 -11.8 ± 8.2 LL00239FE38 -8 -62 1 -0.5 ± 1.6 -0.5 ± 2.2 -2.9 ± 9.1 LL00240FE39 2 54 0 -0.1 * 0.1 2.5 ± 2.8 -11.0 ± 8.1 LL00241FE40 7 179 0 0.4 ± 1.2 -1.9 ± 1.4 -9.4 ± 8.3 LL00242FE41 12 66 1 -0.2 ± 0.2 2.3 t 2.9 -14.5 ± 8.2 LL00243FE42 -3 111 1 1.3 ± 2.5 0.9 ± 2.7 -5.7 ± 9.0 LL00244FE43 7 -66 1 -0.1 * 0.1 1.6 ± 2.5 -2.6 ± 10.2 LL00245FE44 2 155 1 0.4 ± 1.2 -0.5 ± 2.0 -6.3 ± 8.9 LL00246FE45 7 71 0 -0.2 ± 0.2 -0.9 ± 1.6 -7.8 ± 9.3 LL00247FE46 2 111 1 1.8 ± 2.8 -0.5 ± 2.2 -7.3 ± 10.4 LL00248FE47 -8 38 0 0.5 ± 1.2 -0.2 ± 1.8 -12.3 ± 9.1 LL00249FE48 -8 107 0 0.4 ± 1.2 0.8 ± 2.6 -13.9 ± 8.3 LL00250

C-11-5

Page 64: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27.-MH-4939-R-97, Facility Close-out--andTermination Surv, Camp Nmer, NJ, 1 Jul - 20 Dec 97

* Camp Kilmer, BUILDING 1072 ROOM 9 "Location Monitoring .... _- : Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cmA2 dpm/llOOcMA2 uRlhr dpm/1OOcmA^2 +1-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9(MDA >) 52 284 - 2.44 -2.39 49.02 "

FE49 -3 115 0 -0.2 t 0.2 -0.9 + 1.6 -10.2 ± 9.0 LL00251FE50 -8 71 0 0.7 t 2.3 -0.5 t 2.2 -12.1 t 9.4 LL00252FF1 -8 119 1 -0.1 :1: 0.1 -1.1 ± 1.3 -8.5 ± 8.7 LL00253FF2 -3 46 1 -0.2 ± 0.2 0.4 ± 2.4 -3.7 ± 8.3 LL00254FF3 -8 22 1 0.4 : 1.2 0.4 + 2.2 -7.9 ± 8.0 LL00255FF4 .- 3 71 0 1.3 ± 2.5 0.0 ± 2.4 -5.8 ± 8.3 LL00256

FF5 7 58 0 -0.1 ± 0.1 -0.6 ±"1.6 -1.7 ± 8.5 LL00257

FF6 -8 -10 1 0.4 ± 1.2 1.3 ± 2.7 -2.7 ± 8.6 LL00258

FF7, 2 50 0 -0.2 ± 0.2 2.7 ± 3.0 -3.2 ± 8.3 LL00259

FF8 -13 i 111 1 0.1 t 2.0 0.0 ± 2.4 -4.3 ± 7.6 LL00260

FF9 12 103. 1 -0.1 ± 0.1 -1.1 ± 1.3 -3.9 ± 7.6 LL00261FF10 33 79 0 -0.2 ± 0.2 -1.0 ± 1.8 1.2 ,- 8.0 LL00262

FF11 17 34 0 -0.2 ± 0.2 0.0 ± 2.0 -2.0 + 7.7 LL00263

FF12 -3 -115 0 0.7-± -2.3 2.2 ± 3.1 -4.2 ± 8.2 LL00264FF13 -8 62 0 0.5 ± 1.2 1.1 ± 2.3 -7.9 ± 8.7 LL00265FF14 2 -30 0 0.4 ± 1.2 -0.1 ± 2.2 -11.2 ± 9.9 LL00266FF15 -3 -18 0 0.4 ± .1.2- 0.4 ± 2.2 -4.6 :110.3 LL00267FF16 -3 -79" 1 1.3 ± 2.5 -1.4 ± 1.8 -5.2 ± "9.1 LL00268FF17 2 -34 0 -0.1 ± 0.1 -0.6 ± 1.6 -11.7 + 9.2 LL00269FF18 7 26 0 0.4 ± 1.2 1.3 ± 2.7 -0.2 + 9.9 LL00270FF19 -3 18. 0 -0.2 ± 0.2 -1.4 ± 1.3 2.0 ± 9.6 LL00271FF20 .28 22 0 0.7 t 2.3 3.6 ± 3.4 -2.5 : 9.9 LL00272FF21 12 -30 0 -0.1 ± 0.1 0.7 ± 2.2 -12.3 ± 9.1 LL00273FF22 7 34 0 -0.2 ± 0.2 2.2 ± 3.0 -7.8 ± 9.3 LL00274

FF23 2 42 0 -0.2 ± 0.2 0.0 ± 2.0 -4.7 ± 9.4 LL00275

FF24 -3 131 1 0.1 ± 2.0 0.4 ± 2.5 -3.6 ± 9.5 LL00276

FF25 7 139 0 -0.1 ± 0.1 0.7 ± 2.2 -4.1 ± 9.2 LL00277FF26 12 95 0 -0.2 ± 0.2 -1.9 ± 1.4 -3.8 * 10.1 LL00278FF27 2. 2 0 -0.2 ±0.2 0.0 ± 2.0 -5.0 ± 11.4 LL00279

FF28 -8 10 -1 0.7 ± 2.3 0.4 ± 2.5 -7.9 ± 8.7 LL00280FF29 7 87 0 -0.1 + 0.1 0.2 ± 2.0 -5.6 ± 9.9 LL00281FF30 -3 151 0 0.4 ± 1.2 -0.1 ± 2.2 -3.8 ± 10.1 LL00282

FF31 -8 135 0 -0.2 - 0.2 3.6 ± 3.2 -13.7, ± 9.6 LL00283

FF32... -13 135 0 1.8 ± 2.8 -0.5 ± 2.2 -4.4 ± 10.0 LL00284FF33 .. 2 155 0 -0.1 ± 0.1 1.6 ± 2.5 -2.2 ± 8.7 LL00285

FF34 -3 111 0 0.4 ± 1.2 1.3 ± 2.7 -11.4 ± 8.9 LL00286FF35 17 95 0 -0.2 + 0.2 0.9 ± 2.4 -8.7 + 8.9 LL00287FF36 2 171 0 0.7 ± 2.3 -1.8 ± 1.6 -9.4 ± 7.8 LL00288FF37 12.- 127 0 -0.1 ± 0.1 2.9 ± 2.9 -4.8 ± 7.5 LL00289FF38 .23 54 0 -0.2 ± 0.2 0.8 ± 2.6 -1.1 ± 7.8 LL00290

FF39 2 10 0 -0.2 ± 0.2 -1.4 ± 1.3 -5.1 ± 7.3 LL00291FF40 -8 2 0 1.3 ± 2.5 -1.8 ± 1.6 -1.7 ± 8.9 LL00292FF41 -13 50 0 0.5 ± 1.2 0.2 ± 2.0 -4.1 ± 9.2 LL00293FF42 -8 115 0 0.4 ± 1.2 -0.1 ± 2.2 -5.4 ± 8.5 LL00294FF43 7. 143 0 0.4 ± 1.2 -0.5 ± 1.8 -9.3 ± 8.8 LL00295

FF44 -13 107 0 1.3 ± 2.5 -0.9 1 2.0 -5.2 :19.1 LL00296FF45 7 111 0 -0.1 ± 0.1 -0.2 ± 1.8 -3.2 ± 10.2 LL00297

FF46 17 22 0 -0.2 ± 0.2 -0.1 ± 2.2 -1.9 ± 10.0 LL00298FF47 -8 139 0 -0.2 ± 0.2 1.3 ± 2.6 -5.6 + 8.8 LL00299

FF48 -13 199 0 1.8 ± 2.8 -2.3 ± 1.3 -6.7 ± 8.6 LLO0300

C-11-6

Page 65: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. *7--.MH-4939-R-97, Facility Close-c andTermination Surv, Cam, .ilmer, NJ, 1 Jul - 20 Dec 97

.... pCamp Kilmer, BUILDING 1072 ROOM 9Location Monitoring -. Wipe Test

Code Alpha Beta Gamma Alpha -- Beta LS Wipe

(Units =>) dpm/1OOcmA2 dpMrn1OOcmA2 uRPhr dpmr/1OOcmA2 +/- 2 sigma Number

(Bkgd =>) 5. 0.0 to 0.34 0.89 to. 1.41 7.86 to 7.9(MDA >) 52 284 . 2.44 .......... 2.39 ." 49.02FF49 7 171 1 -0.1 ± 0.1 0.7 ± 2.2 -11.7 -± 9.2 LL00301FF50 17 171 1 -0.2 ± 0.2 -1.5 ±. 1.6 -7.6 ± 9.1 LL00302QA N/A N/A N/A -0.2 ± 0.2 0.4 ± 2.2 432.8 ± 28.3 LL00303FG1 -3 -30 0 1.3 ± 2.5 0.0 ± 2.4 -0.7- ± 9.3 LL00304FG2 2 87 0 0.5 ± 1.2 2.5 ± 2.8 -8.3 ± 8.4 LL00305FG3 2 -75 0 0.4 ± 1.2 0.4 ± 2.4 0.4. ± 8.7 LL00306FG4 -3 14 0 -0.2 ±. 0.2 0.4 ± 2.2 -6.2 ± 8.0 LL00307FG5 2 -10 0 1.8 ±..2.8 -2.3 ± 1.3 -2.1 ± 8.2 LL00308FG6 . -3 58 1 0.5 ± 1.2 0.7 ± 2.2 -1.7 ± 8.7 LL00309FG7 2 147 0 -02. ± 0.2 -0.1 ± 2.2 -2.7 ± 8.4 LL00310FG8 28 -22 0 0.4 ± 1.2 0.9 ± 2.4 1.3 ± 8.2 LL00311FG9 2 95 0- 4.1 ± 3.6 -2.3 ± 1.3 -0.1 ± 8.1 LL00312FG10 17 34 -0 ... 0.1 .: 0.1 1.1 ± 2.3 -4.3 ± 7.6 LL00313FG11 17 151 0 - 0.2. ± 0.2 0.4 ± 2.4 -4.2 ± 7.4 LL00314FG12 -13 46 0 -0.2 ± 0.2 1.3 ± 2.6 -5.4 ± 7.7 LL00315FG13 17 -50 0 3.0 ± 3.2 0.0..± 2.4 1.9 ± 8.9 LL00316FG14 -8 -2 0 0.5 ± 1.2 1.6 ± 2.5 -6.5 ± 8.4 LL00317FG15 2 22- 0. -0.2 ± 0.2 0.4 ± 2.4 -0.2 ± 9.1 LL00318FG16 2 -26 0 . -0.2 + 0.2 -0.5 ± 1.8 4.4 ± 10.4 LL00319FG17 -8 -62 0 1.8 ± 2.8 0.0 ± 2.4 -5.5 ± 9.6 LL00320FG18 7 103 0 1.1 ± 1.7 2.0 ± 2.6- -5.0 ± 8.8 LL00321FG19 12 -22 0 -0.2 ± 0.2 -0.9 ± 1.6 -7.6 ± 9.1 LL00322FG20 -3 -14 0 3.0 ± 3.2 -0.9 ± 2.0 -8.7 ± 9.5 LL00323FG21 17 99 0 -0.1 t 0.1 1.6 ± 2.5 -3.8 ± 10.1 LL00324FG22 2 83 0 -0.2. ± 0.2 3.5 ± 3.4 -1.4 ± 10.4 LL00325FG23 -3 42 1 -0.2 ± 0.2 0.4 ± 2.2 -3.6 ± 9.5 LL00326FG24 2 151 0 2.4 ± 3.0 0.4 ± 2.5 -1.3 ± 9.8 LL00327FG25 -8 95 0 0.5 ± 1.2 1.6 ± 2.5 -6.2 * 9.8 LL00328FG26 -8 103 -1 -0.2 ± 0.2 -0.5 ± 2.0 -6.8 ± 8.9 LL00329FG27 7 38 0 0.4 ± 1.2 -0.9 ± 1.6 -16.1 ± 12.6 LL00330FG28 -8 -34 0 3.0 ± 3.2 -1.8 ± 1.6 -1.9 .± 10.0 LL00331FG29 7 -34 0 -0.1 ± 0.1 1.1 ± 2.3 0.4 ± 10.3 LL00332FG30 7 83 0 -0.2 ± 0.2 -1.0 ± 1.8 -4.2 ± 9.5 LL00333FG31 23 139 1 -0.2 ± 0.2 0.0 ± 2.0 -4.9 ± 11.0 LL00334-FG32 -3 -6 0 -0.3 ± 0.2 2.9 ± 3.5 -6.4 ± 10.1 LL00335FG33 2 -22 0 -0.1 ± 0.1 -0.6. ± 1.6 -6.5 ± 9.2 LL00336FG34 2 -2 0 -0.2 ± 0.2 0.4 ± 2.4 -7.2 ± 9.4- LL00337FG35 17 147 0 .1.0 ± 1.7 1.3 ± 2.6 -5.8 ± 10.2 LL00338FG36 -8 50 0 3.0 ± 3.2.... 5. ± 2.2 -9.9 ± 8.2 LL00339FG37 -3 91 0 0.5 ± 1.2 -1.5 ± 1.0 -11.0 ± 8.6 LL00340FG38 2 91 0 -0.2 ± 0.2 1.3 ± 2.7 -7.0 ± 7.7 LL00341FG39 2 6 0 1.0 ± 1.7 0.0 ± 2.0 -0.1 ± 8.1 LL00342FG40 2 199 1 3.6 ± 3.4 0.4 ± 2.5 -1.7 ± 8.5 LL00343FG41 2 -18 0 -0.1 ± 0.1 -0.6 ± 1.6 -12.1 ± 9.4 LL00344FG42 2 119 0 0.4 ± 1.2 0.4 ± 2.4 6.9 ± 9.4 LL00345FG43 7 62 0 -0.2 ± 0.2 0.0 ± 2.0 0.4 ± 10.0 LL00346FG44 12 119 0 . 1.8 ± 2.8 -1.8 ± 1.6 -10.2 ± 9.0 LL00347FG45 -3 46 0 -0.1 ± 0.1 1.1 ± 2.3 -10.9 ± 11.1 LL00348FG46 -3 127 0 -0.2 ± 0.2 -0.1 ± 2.2 -11.2 ± 9.9 LL00349FG47 -3 42 0 0.4 ± 1.2 1.8 ± 2.7 -8.3 ± 9.9 LL00350

C-11-7

Page 66: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-'MH-4939-R-97, Facility Close-ou-IndTermination Surv, Camp ..- lmer, NJ, I Jul - 20 Dec 97 - . )

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/100cmA2 dpm/100cmA2 uRPhr dpm/100cmA2 +1-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA =>) 52 284 - 2.44 * 2.39 49.02 *

FG48 -3 87 0 3.6 ± 3.4 -0.5 ± 2.2 -3.0 ± 11.7 LL00351

FG49 2 91 0 -0.1 ± 0.1 0.7 t 2.2 -12.5 ± 9.7 LL00352

FG50 2 71 0 -0.2 ± 0.2 1.3 ± 2.7 -6.1 ± 9.5 LL00353

FHl 7 143 0 -0.2 ± 0.2 -1.4 ± 1.3 -6.9 ± 9.7 LL00354

FH2 2 143 0 3.6 ± 3.4 1.8 ± 3.0 -5.2 ± 9.1 LL00355

FH3 7 71 1 -0.1 ± 0.1 1.1 ± 2.3 -8.1 ± 9.6 LL00356

FH4 2 26 1 -0.2 ± 0.2 -0.5 ± 2.0 -1.2 ± 8.8 LL00357

FH5 -8 79 1 -0.2 ± 0.2 -0.5 ± 1.8 1.5 ± 10.1 LL00358

FH6 2 58 0 3.0 ± 3.2 0.0 ± 2.4 -4.7 ± 9.4 LL00359

FH7 -3 42 0 -0.1 ± 0.1 -0.2 ± 1.8 -7.5 ± 9.7 LL00360

FH8 -3 58 0 -0.2 + 0.2 0.8 ± 2.6 -3.3 ± 8.8 LL00361

FH9 12 18 0 0.4 ± 1.2 1.3 ± 2.6 -4.5 ± 8.9 LL00362

FH10 2 -83 -1 3.6 ± 3.4 0.0 ± 2.4 -4.6 ± 9.1 LL00363

FHll 12 -22 0 -0.1 ± 0.1 -0.2 ± 1.8 -3.1 ± 8.1 LL00364

FH12 -8 -62 0 -0.2 ± 0.2 -0.5 ± 2.0 -3.4 ± 9.0 LL00365

FH13 2 14 0 -0.2 ± 0.2 0.4 ± 2.2 -1.4 ± 10.1 LL00366

FH14 12 -38 0 0.5 + 1.5 1.8 ± 3.1 -4.4 ± 10.0 LL00367

FH15 12 -107 0 -0.1 ± 0.1 -1.1 ± 1.3 -2.2 ± 11.3 LL00368

FH16 -3 119 0 1.0 ± 1.7 -0.1 ± 2.2 -8.1 ± 11.5 LL00369

FH17 -8 83 0 -0.2 ± 0.2 0.0 ± 2.0 -8.9 ± 10.6 LL00370

FH18 -8 103 0 3.6 ± 3.4 -1.4 ± 1.8 -11.2 ± 10.7 LL00371

FH19 2 119 0 -0.1 ± 0.1 0.7 ± 2.2 -9.9 ± 10.8 LL00372

FH20 -8 54 0 0.4 ± 1.2 -1.9 ± 1.4 -17.2 ± 11.3 LL00373

FH21 -3 191 1 0.4 ± 1.2 1.3 ± 2.6 -3.0 ± 11.7 LL00374

FH22 2 159 0 1.8 ± 2.8 0.0 ± 2.4 -10.6 ± 11.6 LL00375

FH23 2 6 0 0.5 ± 1.2 1.6 ± 2.5 -3.7 ± 11.6 LL00376

FH24 23 111 0 -0.2 ± 0.2 -1.0 ± 1.8 -12.8 ± 13.0 LL00377

FH25 7 58 0 -0.2 ± 0.2 0.4 ± 2.2 -6.6 ± 11.7 LL00378

FH26 -3 38 -1 3.6 ± 3.4 -0.5 ± 2.2 -12.1 ± 9.4 LL00379

FH27 2 58 0 -0.1 ± 0.1 -0.2 ± 1.8 -14.1 ± 11.7 LL00380

FH28 2 58 0 -0.2 ± 0.2 0.8 ± 2.6 -13.8 ± 12.3 LL00381FH29 2 79 0 -0.2 ± 0.2 -0.9 ± 1.6 -23.1 ± 13.8 LL00382

FH30 -3 107 0 3.0 ± 3.2 -0.9 ± 2.0 -12.5 ± 11.9 LL00383

FH31 2 -10 0 -0.1 ± 0.1 0.2 ± 2.0 -9.8 ± 12.8 LL00384

FH32 2 111 0 -0.2 ± 0.2 0.4 ± 2.4 -14.2 ± 13.5 LL00385

FH33 7 54 0 -0.2 ± 0.2 -0.5 ± 1.8 -13.6 ± 12.9 LL00386

FH34 7 111 0 3.6 ± 3.4 -0.5 ± 2.2 -16.1 ± 12.6 LL00387

FH35 2 83 0 -0.1 ± 0.1 0.7 ± 2.2 -11.1 ± 13.2 LL00388

FH36 7 171 0 0.4 ± 1.2 -0.5 ± 2.0 -14.7 ± 10.2 LL00389

FH37 12 75 0 0.4 ± 1.2 0.0 ± 2.0 -0.2 ± 11.2 LL00390

FH38 2 111 0 -0.3 ± 0.2 2.9 ± 3.5 1.5 ± 9.8 LL00391

FH39 -3 75 0 -0.1 ± 0.1 1.1 ± 2.3 -2.8 ± 8.8 LL00392

FH40 17 83 0 -0.2 ± 0.2 -0.5 ± 2.0 -8.2 ± 10.6 LL00393

FH41 -13 163 0 -0.2 ± 0.2 0.4 ± 2.2 1.0 ± 10.3 LL00394

FH42 -3 14 0 -0.3 ± 0.2 1.3 ± 2.9 -2.4 ± 9.4 LL00395

FH43 -3 159 0 -0.1 ± 0.1 0.7 ± 2.2 2.5 ± 9.4 LL00396

FH44 -8 135 0 -0.2 ± 0.2 1.7 ± 2.9 -4.4 ± 10.0 LL00397

FH45 7 103 0 0.4 ± 1.2 2.3 ± 2.9 -8.6 ± 10.2 LL00398

FH46 12 135 0 -0.3 ± 0.2 2.9 ± 3.5 -7.9 ± 10.3 LL00399

FH47 -3 119 0 -0.1 ± 0.1 -1.5 ± 1.0 -7.3 ± 10.4 LLOD400

C-11-8

Page 67: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radr Surv No. 7C Ki4939-R-97, Facility CloseN7O andTermination Surv, Cam. .ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code. Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cmA2 dpmr1100cmA2 uR/hr dpmr1OOcmA2 +1-2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9(MDA >) 52 284 - 2.44 * 2.39 49.02 *FH48 -8 42 0 0.4 ± 1.2 1.7 ± 2.9 -10.2 ± 9.7 LL00401FH49 -3 211 0 -0.2 ± 0.2 -0.9 ± 1.6 -7.7 . ± 10.0 LL00402FH50 -3 139 0 -0.3 ± 0.2 3.5 ± 3.6 -9.9 ± 10.1 LL00403QA N/A N/A NIA -0.1 ± 0.1 -0.6 ± 1.6 244.3 ± 21.8 LL00404F11 2 103 0 -0.2 ± 0.2 1.7 ± 2.9 -8.5 ± 11.0 LL00405F12 7 119 0 -0.2 ± 0.2 -0.9 ± 1.6 -0.9 ± 11.5 LL00406F13 17 131 0 -0.3 ± 0.2 0.2 ± 2.5 -11.1 ± 9.2 LL00407F14 12 123 0 -0.1 ± 0.1 -0.2 ± 1.8 -6.8 ± 8.1 LL00408FI5 -3 22 0 -0.2 ± 0.2 0.8 ± 2.6 -2.7 ± 8.4 LL00409FI6 23 50 1 -0.2 ± 0.2 0.4 t 2.2 -2.7 ± 8.6 LL00410F17 -13 115 0 -0.3 ± 0.2 -0.9 ± 2.0 6.9 ± 10.1 LL00411F118 -3 131 0 -0.1 ± 0.1 -2.0 ± 0.4 -1.7 ± 8.5 LL00412F19 -3 30 0 -0.2 ± 0.2 -1.9 ± 1.4 1.7 ± 8.1 LL00413FI10 7 79 0 -0.2 ± 0.2 -0.5 ± 1.8 0.3 ± 8.5 LL00414Fill -3 26 0 -0.3 ± 0.2 0.7 ± 2.7 -1.6 ± 8.1 LL00415F112 2 99 0 -0.1 ± 0.1 -0.6 ± 1.6 -2.7 ± 8.4 LL00416F113 -3 34 0 0.4 ± 1.2 -1.0 ± 1.8 -7.5 ± 9-.7 LL00417F114 -13 75" 0 0.4 ± 1.2 1.3 ± 2.6 -1.9 ± 9.7 LL00418F115 12 103 0 3.6 ± 3.4 -0.9 ± 2.0 -11.2 ± 10.7 LL00419F116 -13 -38 0 1.1 ± 1.7 0.7 ± 2.2 -8.8 ± 11.4 LL00420F117 -3 167 0 1.0 ± 1.7 1.3 ± 2.7 -10.2 ± 11.2 LL00421F118 -8 87 0 -0.2 ± 0.2 0.9 ± 2.4 -3.2 ± 12.5 LL00422F119 2 127 1 3.0 ± 3.2 -0.9 ± 2.0 -4.3 ± 11.5 LL00423F120 -3 151 0 0.5 ± 1.2 -0.6 ± 1.6 -5.0 ± 10.0 LL00424F121 -8 66 0 -0.2 ±, 0.2 -2.8 ± 0.5 -5.0 ± 11.4 LL00425F122 -8 58 0 0.4 ± 1.2 1.3 ± 2.6 -6.9 ± 10.8 LL00426F123 -8 103 0 0.5 ± 1.5 1.3 ± 2.9 -1.9 ± 14.3 LL00427F124 17 111 0 -0.1 ± 0.1 0.7 ± 2.2 -6.4 ± 14.4 LL00428F125 7 79 0 -0.2 ± 0.2 0.8 ± 2.6 -11.2 ± 14.5 LL00429F126 -13 62 0 -0.2 ± 0.2 0.9 ± 2.4 -3.8 ± .10.1 LL00430F127 -13 119 0 0.5 ± 1.5 3.5 ± 3.6 -12.8 ± 13.0 LL00431F128 -3 103 0 0.5 ± 1.2 1.6 ± 2.5 -12.1 ± 11.5 LL00432F129 2 62 1 0.4 ±. 1.2 -1.5 ± 1.6 -15.7 ± 14.0 LL00433F130 -3 159 1 -0.2 ± 0.2 0.0 ± 2.0 -17.3 ± 10.8 LL00434F131 2 71 0 0.5 ± 1.5 0.7 ± 2.7 -7.1 ± 11.2 LL00435F132 7 163 1 0.5 ± 1.2 -0.2 ± 1.8 -14.9 ± 9.8 LL00436F133 12 91 1 0.4 ± 1.2 0.4 1 2.4 -10.9 ± 10.3 LL00437F134 12 211 0 0.4 ± 1.2 -1.4 ± 1.3 -8.8 ± 11.4 LL00438F135 2 46 1 -0.3 ± 0.2 -0.9 ± 2.0 -6.6 ± 13.2 LL00439F136 2 143 0 -0.1 ± 0.1 0.2 ± 2.0 -4.9 ± 11.0 LL00440F137 7 119 1 0.4 ± 1.2 -1.9 ± 1.4 -3.0 ± 9.6 LL00441F138 7 127 0 0.4 ± 1.2 1.3 ± 2.6 1.6 ± 10.7 LL00442F139 7 66 0 -0.3 ± 0.2 1.8 ± 3.1 5.0 ± 9.4 LL00443F140 -3 26 0 -0.1 ± 0.1 0.2 ± 2.0 -3.7 ± 9.8 LL00444F141 -8 91 0 -0.2 ± 0.2 0.8 ± 2.6 -12.1 ± 9.4 LL00445F142 17 179 0 1.0 ± 1.7 1.3 ± 2.6 -0.7 ± 9.3 LL00446F143 -3 191 0 -0.3 ± 0.2 2.4 ± 3.3 -8.2 ± 9.0 LL00447F144 2 46 0 -0.1 ± 0.1 0.2 ± 2.0 -6.2 ± 9.8 LL00448F145 2 71 0 -0.2 ± 0.2 -1.0 ± 1.8 -8.4 ± 7.9 LL00449F146 -3 151 0 -0.2 ± 0.2 0.4 ± 2.2 -4.9 ± 9.7 LL0045O

C-1 1-9

Page 68: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-out andTermination Surv, Camp- Lmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9 ' .. .

Location Monitoring _ _ i Wipe TestCode Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpmr/100cmA2 dpmn/100cmA2 uR/hr dpm/100cmA2 +/-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA >) 52 284 - 2.44 2.39 " 49.02

F147 -8 87 0 0.5 ± 1.5 1.8 ± 3.1 -6.4 ± 10.1 LL00451

F148 -3 75 0 0.5 ± 1.2 1.1 ± 2.3 -11.4 ± 12.6 LL00452

F149 2 -6 0 0.4 ± 1.2 1.7 ± 2.9 -8.5 ± 11.0 LL00453

F150 17 -2 0 -0.2 ± 0.2 1.3 ± 2.6 -14.5 ± 10.7 LL00454

FJ1 17 79 0 0.5 ± 1.5 1.8 ± 3.1 -0.9 ± 12.3 LL00455

FJ2 -8 50 0 -0.1 ± 0.1 0.2 ± 2.0 -3.0 ± 9.6 LL00456

F.J3 -3 171 0 -0.2 ± 0.2 0.8 ± 2.6 -1.4 ± 10.1 LL00457

FJ4 2 22 1 -0.2 ± 0.2 -0.9 ± 1.6 -1.9 ± 9.7 LL00458

F.J5 2 119 0 -0.3 ± 0.2 1.8 ± 3.1 -7.5 ± 9.7 LL00459

F.J6 7 163 0 -0.1 ± 0.1 -1.5 ± 1.0 -3.4 ± 9.0 LL00460

F.J7 7 83 0 -0.2 ± 0.2 -0.5 ± 2.0 -12.5 ± 11.9 LL00461

F.J8 -8 135 0 -0.2 ± 0.2 0.0 ± 2.0 -5.4 ± 10.6 LL00462

F.J9 -3 95 0 0.5 ± 1.5 1.3 ± 2.9 2.5 ± 9.4 LL00463

FJ10 12 187 0 -0.1 ± 0.1 -0.2 ± 1.8 1.3 ± 8.4 LL00464

FJ111 7 38 0 0.4 ± 1.2 -0.1 ± 2.2 -11.3 ± 11.6 LL00465

FJ12 2 6 0 -0.2 ± 0.2 1.8 ± 2.7 -3.7 ± 9.8 LL00466

FJ13 -3 135 0 0.5 ± 1.5 2.9 ± 35" t-1.9 ± 9.7 LL00467

FJ14 2 42- 0. 0.5 ± 1.2 -0.6 ± 1.6 -5.4 ± 10.6 LL00468

FJ15 -3 107 0 -0.2 ± 0.2 1.7 ± 2.9 -3.8 ± 12.0 LL00469

FJ16 -3 -30 0 -0.2 ± 0.2 0.9 ± 2.4 -5.2 ± 10.3 LL00470

FJ17 2 139 0 -0.3 ± 0.2 2.4 ± 3.3 -7.8 ± 11.1 LL00471

FJ18 -13 103 0 0.5 ± 1.2 4.7 :13.4 0.5 ± 12.9 LL00472

FJ19 7 75 0 -0.2 ± 0.2 0.8 ± 2.6 -3.3 ± 10.5 LL00473

FJ20 -3 58 0 -0.2 ± 0.2 0.9 ± 2.4 -12.1 ± 11.5 LL00474

FJ21 -8 151 0 -0.3 ± 0.2 2.4 ± 3.3 -11.9 ± 13.1 LL00475

FJ22 2 103 0 -0.1 ± 0.1 -0.6 ± 1.6 -17.2 ± 11.3 LL00476

FJ23 -8 71 -1 -0.2 * 0.2 0.4 O 2.4 -11.8 ± 12.0 LL00477

FJ24 -3 -91 0 1.6 ± 2.1 0.4 1 2.2 -13.8 ± 12.3 LL00478

FJ25 -8 34 0 -0.3 * 0.2 0.7 ± 2.7 -7.4 ± 13.1 LL00479

FJ26 2 -14 0 1.1 ± 1.7 3.8 ± 3.2 -16.6 ± 13.8 LL00480

FJ27 -3 159 0 1.6 ± 2.1 -0.1 ± 2.2 -11.2 ± 14.5 LL00481

FJ28 2 -2 0 -0.2 ± 0.2 -0.5 ± 1.8 -14.3 ± 11.2 LL00482

FJ29 -8 34 0 -0.3 ± 0.2 0.2 ± 2.5 -4.1 ± 12.9 LL00483

FJ30 -8 147 0 -0.1 ± 0.1 0.2 ± 2.0 -9.8 ± 14.0 LL00484

FJ31 -8 75 0 0.4 ± 1.2 -0.5 ± 2.0 -11.1 ± 13.2 LL00485

FJ32 7 91 0 -0.2 ± 0.2 0.4 ± 2.2 -9.0 ± 12.9 LL00486

FJ33 2 207 0 -0.3 ± 0.2 1.3 ± 2.9 -9.6 ± 9.8 .L00487

FJ34 7 260 0 -0.1 ± 0.1 0.7 ± 2.2 -11.2 ± 10.7 LL00488

FJ35 -8 95 0 -0.2 ± 0.2 0.8 ± 2.6 -9.2 ± 10.1 LL00489

FJ36 -3 6 0 -0.2 ± 0.2 0.9 ± 2.4 -7.9 ± 8.0 LL00490

F J37 -3 143 0 -0.3 ± 0.2 -1.5 ± 1.6 -4.9 ± 8.6 LL00491

FPJ38 -8 155 0 -0.1 ± 0.1 2.5 ± 2.8 -2.0 ± 7.9 LL00492

FPJ39 7 87 0 -0.2 ± 0.2 0.4 ± 2.4 0.4 ± 9.2 LL00493

FJ40 2 127 0 -0.2 ± 0.2 1.3 ± 2.6 0.9 ± 8.8 LL00494

FJ41 7 179 0 -0.3 ± 0.2 0.2 ± 2.5 -7.2 ± 9.4 .L00495

FPJ42 -3 123 0 -0.1 ± 0.1 0.7 ± 2.2 -4.3 ± 8.4 LL00496

FPJ43 2 38 0 -0.2 ± 0.2 -1.5 ± 1.6 -6.1 ± 8.7 LL00497

FPJ44 2 107 0 1.0 ± 1.7 0.0 ± 2.0 -9.6 ± 9.8 LL00498

FPJ45 7 2 0 0.5 ± 1.5 -2.0 ± 1.2 -6.2 ± 9.8 LL00499

FJ46 -3 203 0 -0.1 ± 0.1 0.7 ± 2.2 -7.7 ± 8.5 LL00500

C-11-10

Page 69: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. -m K-4939-R-97, Facility Closec 9 andTermination Surv, Carr.. 7ilmer, NJ, 1 Jul - 20 Dec 97

.Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpnmlOOcm^2 dpm/1OOcmA^2 uRlhr dpml/00cm^2 -1-2 sigma Number

(Bkgd=>) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA 5>) 2 284 2.44 " 2.39 " 49.02 -

FJ47 -3 42 0 -0.2 ± 0.2 0.4 ± 2.4 -6.7 ± 9.5 LL00501FJ48 -8 38 0 -0.2 ± 0.2 0.9 ± 2.4 1.5 ± 10.1 LL00502FJ49 -3 159 0 -0.3 ± 0.2 1.3 ± 2.9 -4.3 ± 11.5 LL00503FJ50 -3 115 0 -0.1 ± 0.1 -1.1 ± 1.3 -7.8 ± 11.1 LL00504QA N/A N/A N/A -0.2 ± 0.2 -0.5 ± 2.0 938.4 ± 42.8 LL00505FK1 2 127 0 0.4 ± 1.2 0.9 ± 2.4 -12.1 ± 14.4 LL00506FK2 7 308 0 -0.3 ± 0.2 3.5 ± 3.6 -3.9 ± 10.4 LL00507FK3 17 171 0 0.5 ± 1.2 0.2 ± 2.0 -4.3 ± 9.7 LL00508FK4 -3 228 0 0.4 ± 1.2 -1.5 ± 1.6 -6.4 ± 10.1 LL00509FK5 -13 127 0 -0.2 ± 0.2 1.3 ± 2.6 -5.0 ± 10.0 LL00510FK6 17 171 -1 -0.3 ± 0.2 1.8 ± 3.1 -3.8 ± 10.1 LL00511FK7 2 42 0 -0.1 ± 0.1 0.7 ± 2.2 -6.8 ± 8.9 LL00512FK8 -8 139 0 0.4 ± 1.2 0.4 ± 2.4 -6.4 ± 12.6 LL00513FK9 2 131 0 -0.2 ± 0.2 3.2 ± 3.1 -5.0 ± 13.3 LL00514FK10 12 211 0 2.1 ± 2.6 1.8 ± 3.1 1.5 ± 7.0 LL00515FK11 2 91 0 0.5 ± 1.2 0.2 ± 2.0 -8.1 ± 18.4 LL00516FK12 7 143 1 0.4 ± 1.2 0.0 ± 2.0 -11.3 ± 16.1 LL00517FK13 7 71. 0 -0.3 ± 0.2 -0.4 ± 2.2 2.0 ± 13.1 LL00518FK14 12 107 0 -0.1 ± 0.1 -1.5 ± 1.0 -7.8 ± 13.6 LL00519FK15 -3 272 0 -0.2 ± 0.2 0.4 ± 2.4 -11.7 ± 15.2 LL00520FK16 2 30 0 1.0 ± 1.7 2.3 ± 2.9 -0.3 ± 15.1 LL00521FK17 12 216 0 -0.3 ± 0.2 0.2 ± 2.5 -6.6 ± 15.1 LL00522FK18 2 139 0 -0.1 ± 0.1 -0.6 ± 1.6 -1.1 ± 15.0 LL00523FK19 -3 99 0 0.4 ± 1.2 -0.5 ± 2.0 -18.5 ± 13.6 LL00524FK20 -8 248 0 -0.2 ± 0.2 0.0 ± 2.0 -15.0 ± 13.3 LL00525FK21 2 155 0 -0.3 ± 0.2 -0.4 ± 2.2 -20.3 ± 15.9 LL00526FK22 -3 79 0 -0.1 ± 0.1 1.6 ± 2.5 -22.7 ± 17.8 LL00527FK23 12 75 0 -0.2 ± 0.2 0.4 ± 2.4 -8.6 ± 19.5 LL00528FK24 -13 87 0 -0.2 ± 0.2 -0.5 ± 1.8 -23.9 ± 17.6 LL00529FK25 2 83 -1 -0.3 ± 0.2 1.8 ± 3.1 -10.8 ± 17.1 LL00530FK26 -8 115 0 1.7 ± 2.1 0.2 ± 2:0 -15.3 ± 15.6 LL00531FK27 -3 62 0 -0.2 ± 0.2 2.2 ± 3.0 -15.3 ± 12.7 LL00532FK28 -13 111 0 -0.2 ± 0.2 0.0 ± 2.0 -9.4 ± 14.7 LL00533FK29 -8 46 0 -0.3 ± 0.2 0.2 ± 2.5 -13.3 ± 15.8 LL00534FK30 -3 58 0 1.1 ± 1.7 -0.2 ± 1.8 -9.8 ± 15.4 LL00535FK31 2 58 0 -0.2 ± 0.2 -0.1 ± 2.2 -24.8 ± 16.3 LL00536FK32 -3 79 0 0.4 ± 1.2 1.3 ± 2.6 -8.7 ± 12.4 LL00537FK33 -3 216 0 -0.3 ± 0.2 -0.9 ± 2.0 -11.1 ± 13.2 LL00538FK34 7 83 0 0.5 ± 1.2 1.6 ± 2.5 -14.6 ± 12.2 LL00539FK35 2 171 0 -0.2 ± 0.2 -1.0 ± 1.8 -16.9 ± 12.5 LL00540FK36 7 62 0 0.4 ± 1.2 0.9 ± 2.4 -0.8 ± 10.8 LL00541FK37 12 272 0 -0.3 ± 0.2 1.8 ± 3.1 -2.7 ± 8.4 LL00542FK38 -8 111 0 0.5 ± 1.2 1.1 ± 2.3 -6.4 ± 10.1 LL00543FK39 17 87 0 0.5 ± 1.5 0.7 ± 2.7 -6.0 ± 8.5 LL00544FK40 -13 175 0 -0.3 ± 0.2 -0.4 ± 2.2 -5.0 ± 8.8 LL00545FK41 -13 199 0 0.5 ± 1.5 0.7 ± 2.7 -6.7 ± 7.9 LL00546FK42 2 139 1 0.5 ± 1.5 1.8 ± 3.1 -12.4 ± 8.2 LL00547FK43 -8 131 0 0.5 ± 1.5 -0.4 ± 2.2 -6.5 ± 9.2 LL00548FK44 2 2 0 1.0 ± 1.7 3.0 ± 2.9 0.8 ± 8.6 LL00549FK45 -8 99 0 -0.2 ± 0.1 -0.8 ± 1.5 -2.5 ± 9.9 LL00550

C-11-11

Page 70: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-or-,andTermination Surv, CamI Yimer, NJ, 1 Jul - 20 Dec 97

* Camp Kilmer, BUILDING 1072 ROOM 9

Location Monitoring Wipe TestCode, Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/100cm^2 dpm/100cm^n2 uR/hr dpm/100=m^2 +/- 2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA >) 52 284 - 2.44 2.39 49.02FK46 23 135 0 0.4 ± 1.2 -0.8 ± 1.5 -5.3 + 7.5 LL00551FK47 -3 107 0 0.4 ± 1.2 0.0 ± 1.9 -7.6 + 12.0 LL00552FK48 .8 107 1 -0.2 ± 0.1 0.9 ± 2.3 -12.8 + 11.4 LL00553FK49 -3 87 0 -0.2 ± 0.1 -0.4 ± 1.7 -2.7 ± 10.6 LL00554

FK50 -13 119 0 0.4 ± 1.2 1.3 ± 2.4 -11.4 ± 8.9 LL00555FL1 17 167 0 0.4 ± 1.2 0.9 ± 2.3 -2.0 ± 14.9 LL00556FL2 12 131 0 -0.2 ± 0.1 0.0 ± 1.9 -6.9 ± 10.8 LL00557FL3 7 58 1 0.4 ± 1.2 1.8 ± 2.6 -5.0 ± 10.0 LL00558FL4 -3 159 0 -0.2 ± 0.1 -1.2 ± 1.3 -12.2 ± .10.2 LL00559FL5 -13 175 0 -0.2 ± 0.1 0.0 ± 1.9 -7.9 ± 12.5 LL00560FL6 -3 -50 0 0.4 ,± 1.2 0.0 t 1.9 -2.2 ± 11.3 LL00561FL7 -3 147 1 -0.2 * 0.1 -0.4 ± 1.7 -9.8 ± 12.8 LL00562FL8 -3 95 1 -0.2 ± 0.1 0.0 ± 1.9 -14.5 ± 10.7 LL00563FL9 -8 103 0 1.0 ± 1.7 0.9 ± 2.3 -12.4 ± 13.7 LL00564FL10 2 107 0 0.4 ± 1.2 1.8 ± 2.6 -13.7 ± 17.7 L100565FL11 -8 119 0 -0.2 : 0.1 0.0 ± 1.9 .- 7.3 ± 16.6 LL00566FL12 2 . 87 0 -0.2 ± 0.1 -0.4 ± 1.7 -11.9 ± 16.9 LL00567FL13 23 i15 0 -0.2 ± 0.1 0.5 ± 2.1 -14.2 ± 13.5 LL00568FL14 23 224 0 1.0 ± 1.7 2.6 ± 2.8 -17.4 ± 14.5 LL00569FL15 -3 131 -1 0.4 ± 1.2 -1.2 ± 1.3 -13.0 ± 14.3 LL00570FL16 -3 62 0 -0.2 ± 0.1 -0.8 ± 1.5 -13.0 ± 14.3 LL00571FL17 - 7 6 0 -0.2 ± 0.1 2.2 ± 2.7 -14.0 ± 16.7 LL00572FL18 7 135 0 -0.2 ± 0.1 1.8 ± 2.6 -15.9 ± 17.5 LL00573FL19 12 91 0 -0.2 .:t 0.1 -1.7 ± 0.9 -14.8 ± 14.1 LL00574FL20 -3 58 -1 -0.2 ± 0.1 3.5 ± 3.1 -15.9 ± 24.9 LL00575FL21 7 26 -1 1.0 ± 1.7 -0.4 ± 1.7 -12.7 ± 15.1 LL00576FL22 2 54 0 -0.2 ± 0.1 -1.2 ± 1.3 -25.1 ± 17.5 LL00577FL23 7 155 0 -0.2 ±: 0.1 1.3 ± 2.4 -14.6 ± 14.9 LL00578FL24 -13 175 0 1.6 ±: 2.0 2.2 ± 2.7 -12.1 ± 14.4 LL00579FL25 -8 -2 0 0.4- ± 1.2 0.9 ± 2.3 -21.6 + 19.2 LL00580FL26 7 131 -1 1.0 ± 1.7 1.3 ± 2.4 -31.1 ± 19.4 1L.00581FL27 23 42 0 -0.2 ±: 0.1 0.5 ± 2.1 -9.8 : 14.0 LL00582FL28 17 79 0 0.4 ± 1.2 -0.4 ± 1.7 -19.4 ± 12.8 LL00583FL29 12 143 0 -0.2 ± 0.1 0.9 ± 2.3 -36.4 ± 18.7 LL00584FL30 -13 58 -1 -0.2 ±t 0.1 1.8 ± 2.6 -26.6 ± 15.1 LLL00585FL31 -3 131 0 1.0 ± 1.7 0.5 ± 2.1 -14.8 ± 14.1 LL00586FL32 -3 54 0 0.4 ± 1.2 1.8 ± 2.6 -17.2 ± 16.3 LL00587FL33 23 272 1 2.2 t 2.3 1.3 ± 2.4 -16.1 ± 16.4 LL00588FL34 17 107 1 0.4 ± 1.2 -0.8 ± 1.5 -7.6 ± 12.0 LL00589FL35 7 111 0 -0.2 ± 0.1 1.3 ± 2.4 -9.2 t 18.3 LL00590FL36 -8 147 0 0.4 t 1.2 2.2 ± 2.7 -19.3 ± 15.1 LL00591FL37 2 139 1 3.4 ± 2.9 3.5 ± 3.1 -11.6 ± 11.1 LL00592FL38 7 91 0 -0.2 ± 0.1 0.5 ± 2.1 -24.5 ± 15.3 LL00593FL39 23 71 0 0.4 ± 1.2 0.0 ± 1.9 -15.3 ± 12.7 LL00594FL40 -8 58 0 -0.2 ± 0.1 0.9 ± 2.3 -6.7 ± 10.5 LL00595FL41 2 151 1 5.8 ± 3.7 15.1 t 5.3 -3.8 ± 12.0 LL00596FL42 2 115 0 0.4 ± 1.2 0.5 ± 2.1 -2.2 ± 8.4 LL00597

FL43 2 147 1 -0.2 :t 0.1 0.9 ± 2.3 -13.6 ± 11.3 LL00598

FL44 .8 103 0 1.0 + 1.7 2.2 ± 2.7 -4.3 ± 9.7 LL00599FL45 -3 22 0 -0.2 + 0.1 1.3 ± 2.4 " 2.0 ± 9.4 I.L00600

C-11-12

Page 71: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv Noa 71 -4939-R-97, Facility Close-o-'andTermination Surv, Cam d.ilmer, NJ, l'jul - 20 Dec 97"

Camp Kilmer, BUILDING 1072 ROOM 9.Location Monitoring . Wipe Test

Code Alpha Beta Gamma Alpha . •. Beta. LS Wipe

(Units =>) dpm/1OOcmA2 dpmrlOOcmA2 uRlhr dpnmlO00cmr2 +1-2 sigma Number

(Bkgd >) _ _ 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9.(MDA=>) 52 284 .... 2.44 " 2.39 ! 49.02 -

FL46 -3 167 1 -0.2 ± 0.1 1.8 ± 2.6 -2.1 ± 10.6 LL00601FL47 7 111 0 -0.2 ± 0.1 1.3 ± 2.4 7.8 ± 14.7 LL00602FL48 7 119 0 0.4 ± 1.2 -1.2 ± 1.3 -13.7 ± 17.7- LL00603FL49 -8 50 0 1.0 ± 1.7 0.5 + 2.1 -10.3 ± 14.6 LL00604FL50 2 111 1 1.0 ± 1.7 0.9 ± 2.3 -10.6 ± 12.7 LL00605QA N/A NIA N/A -0.3 ± 0.2 -1.8 ± 1.8 -0.2 ± 8.5 LL00606FM1 -3 91 0 -0.3 ± 0.2 . 3.3 ± 3.6 -11.2 ± 14.5 LL00607FM2 7 143 0 0.3 ± 1.3 -0.3 ±. 2.5 -13.6 ± 12.9 LL00608FM3 -3 135 1 -0.3 ± 0.2 -0.3 ± 2.5 -13.0 ± 12.4 LL00609FM4 -8 159 0 -0.3 ± 0.2 -1.3 ± 2.1 3.7. ± 17.8 LL00610FM5 -8 -54 - 1 -0.3 ± 0.2 .-0.3 ± 2.5 -12.6 ± 17.9 LL00611FM6 12 111 0 -0.3 ± 0.2 -1.3 ± 2.1 .. -13.9 ± 14.2 LL00612FM7 -3 119 0 -0.3 + 0.2 0.7 ± 2.9 -13.0 ± 16.8 LL00613.FM8 2 115 1 0.3 ± 1.3 0.7 ± 2.9 -10.3 ± 14.6 LL00614FM9 12 103 1 1.0 ± 1.8 -1.3 ± 2.1 -7.9 ± 20.8 LL00615FM10 -13 83 0 0.3 ± 1.3 0.2 ± 2.7 -3.7 ± 14.7 LLO0616FM11 7 87 0 0.3 ± 1.3. 1.7 ±3.2 -16.1 ± .16.4 LL00617FM12 -8 191" -1 0.3 ± 1.3 3.3 ± 3.6 -10.8 ± 17.1 LL00618FM13 2 143 -1 -0.3 ± 0.2 1.2 ± 3.0 -8.6 ± 13.5 LL00619FM14 -8 135 0 0.3 ± 1.3 0.7. ± 2.9 -14.8 ± 14.1 LL00620FM15 17 139 0 0.3 ± 1.3 -0.3 ± 2.5 -6.1 ± 13.8 LL00621FM16 7 127 0 0.3 ± 1.3 2.8 ± 3.5 -21.4 ± 16.8 LL00622FM17 -8 127 0 1.6 ± 2.2 -0.8 ± 2.3 -22.7 ± 17.8 LL00623FM18. -13 167 0 1.3 ± 2.2 0.2. ± 2.5 -18.4 ± 14.4 LL00624FM19 -3 147 0 1.3 ± 2.2. 1.8 ± 3.1 -19.3- ± 15.1. LL00625-FN20 -8 66 0 -0.3 ± 0.2 6.3 ± 4.4 -18.2 ± 16.2- LL00626FM21 7 71 -1 0.5 ± 1.5 4.6 ± 4.0 -25.9 ± 16.2- LL00627FM22 -3 187 0 -0.3 ± 0.2 -0.4. ± 2.2 -18.4 ± 14.4 LL00628FM23 7 115 0 0.5 ± 1.5 4.0 ± 3.8 -11.0 ± 8.6 LL00629FM24 -8 175 0 -0.3 ± 0.2 2.9 ± 3.5 -18.3 ± 15.2 LL00630FM25 -3 103 1 -0.3 ± 0.2 -0.9 ± 2.0 -16.9 ± 12.5 LL00631FM26 -8 34 -1 -0.3 ± 0.2 0.2 ± 2.5 -10.3 ± 16.2 LL00632FM27 -13 171 0 -0.3 ± 0.2 2.9 ± 3.5 -20.3 ± 14.1 LL00633FM28 -3 83 0 1.3 ± 2.2 2.4 ± 3.3 -16.9 ± 12.5 LL00634FM29 -3 155 - 0 0.5 ± 1.5 .1.8 ± 3.1 -25.9 ± 16.2 LL00635FM30 -8 155 0 0.5 ± 1.5 4.0 ± 3.8 -22.9 ± 19.0 LL00636FM31 -8 139 0 1.3 ± 2.2 3.5 ± 3.6 -19.2 ± 18.2 LL00637FM32 -8 207 0 -0.3 ± 0.2 5.2 ± 4.1 -10.3 ± 18.1 LL00638FM33 -8 62 0 -0.3 ± 0.2 0.7 ± 2.7 -24.8 ± 16.3 LL00639FM34 7 107 0 0.5- ± 1.5. 1.3. ± 2.9 -22.1 ± 13.1 LL00640FM35 -3 62 0 -0.3 ± 0.2 1.3 ± 2.9 -17.3 ± 15.4 LL00641FM36 .. 2 147 0 -0.3 ± 0.2 0.7 ± 2.7 -28.7 ± 14.8 LL00642FM37 -8 147 0 0.5 ± 1.5 2.9 ± 3.5 -15.5 ± 14.7 LL00643FM38 -3 83 0 0.5 ± 1.5 -1.5. ± 1.6 -13.9 ± 14.2 LL00644FM39 -8 131 0 0.5 ± 1.5 1.8 ± 3.1 -11.9 ± 13.1 LL00645FM40 -8 -26 0 -0.3 ± 0.2 -0.9 ± 2.0 -23.3 ± 14.6 LL00646FM41 7 127 0 0.5 ± 1.5 0.2 ± 2.5 -11.7 ± 9.2 LL00647FM42 -8 66 0 1.3 ± 2.2 2.9 ± 3.5 -0.6 ± 8.2 LL00648FM43 -8 159 0 -0.3 ± 0.2 -0.9 ± 2.0 -14.0 ± 10.3 LL00649FM44 7 99 0 -0.3 ± 0.2 5.2 ± 4.1 -13.8 ± 10.8 LL00650

C-11-13

Page 72: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2V-M4H-4939-R-97, Facility Close-or"NandTermination Surv, Cam... lmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring . Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/1OOcmA2 dpmr/1OOcmA2 uR/hr dpm/100cmA2 +/-2 sigma Number

CBkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

CMDA >) 52 284 - 2.44 * 2.39 " 49.02 "

FM45 2. 66 0 -0.3 ± 0.2 2.4 ± 3.3 -17.8 ± 12.4 LL00651[FM46 7 30 0 0.5 ± 1.5 -0.4 ± 2.2 -16.6 ± 19.8 LL00652FM47 -3 -34 0 -0.3 ± 0.2 0.2 ± 2.5 -3.9 ± 15.4 LL00653FM48 12 91 0 1.3 ± 2.2 1.3 ± 2.9 -19.2 ± 17.1 LL00654[FM49 -3 95 1 -0.3 ± 0.2 0.7 ± 2.7 -14.8 ± 14.1 LL00655[FM50 7 147 0 0.5 ± 1.5 0.7 ± 2.7 -13.8 ± 12.3 LL00656FN1 7 -26 0 0.5 ± 1.5 1.8 ± 3.1 -12.1 ± 19.1 LL00657FN2 12 -6 . 0 -0.3 ± 0.2 1.8 ± 3.1 -0.2 ± 13.3 LL00658FN3 -3 175 0 -0.3 ± 0.2 0.2 ± 2.5 -1.7 ± 12.7 LL00659

FN4 -3 155 0 -0.3 ± 0.2 1.8 ± 3.1 - -11.3 ± 16.1 LL00660

FN5 -13 232 1 0.5 ± 1.5 2.4 ± 3.3 -1.9 ± 14.3 LL00661FN6 2 155 1 -0.3 ± 0.2 -0.9 ± 2.0 -8.6 ± 13.5 LL00662FN7 7 62 1 -0.3 ± 0.2 -0.4 ± 2.2 -12.7 ± 15.1 LL00663FN8 -3 -14. 0 -0.3 ± 0.2 -0.4 ± 2.2 -18.2 ± 16.2 LL00664FN9 -13 22 0 -0.3 ± 0.2 1.8 ± 3.1 -12.2 ± 12.5 LL00665FN10 12 75 0 -0.3 ± 0.2 1.3 ± 2.9 -6.6 ± 15.1 LL00666FN11 -8 103 0 -0.3 ± 0.2 1.3 ± 2.9 -18.0 ± 18.4 LL00667FN12 -8 147' 0 -0.3 ± 0.2 1.3 ± 2.9 -8.3 ± 16.4 LL00668FN13 -8 175 1 1.0 ± 1.7 3.0 ± 2.9 -26.2 ± 17.3 LL00669FN14 2 .87 0 0.4 ± 1.2 1.3 ± 2.4 -7.8 ± 13.6 LL00670FN15 -13 123 0 0.4 ± 1.2 0.9 ± 2.3 -20.3 ± 14.1 LL00671FN16 -3 224 0 2.2 ± 2.3 0.5 ± 2.1 -16.3 ± 15.5 LL00672FN17. -8 127 -1 -0.2 ± 0.1 -0.4 ± 1.7 -11.2 ± 14.5 LL00673FN18 -3 155 0 -0.2 ± 0.1 -1.2 ± 1.3 -11.7 ± 15.2 LL00674FN19 7 62 0 1.0 ± 1.7 2.2 ± 2.7 -16.1 ± 16.4 LL00675FN20 -3 135 0 0.4 ±" 1.2 2.2 ± 2.7 -18.2 ± 16.2 LL00676FN21 7 38 0 .- 0.2 ± 0.1 0.9 ± 2.3 -30.4 ± 18.1 LL00677FN22 -8 159 0 2.2 ± 2.3 3.9 ± 3.2 -17.4 ± 14.5 LL00678

FN23 12 131 0 0.4 ± 1.2 1.8 ± 2.6 -15.1 ± 16.5 LL00679FN24 2 220 0 -0.2 ± 0.1 -0.4 ± 1.7 -23.3 ± 14.6 LL00680FN25 -8 131 -1 -0.2 ± 0.1 0.5 ± 2.1 -20.4 ± 19.3 LL00681FN26 -13 123 0 1.0 ± 1.7 1.8 ± 2.6 29.2 ± 19.5 LL00682

FN27 12 207 0 0.4 ± 1.2 0.9 ± 2.3 -24.8 ± 16.3 LL00683FN28, -8 95 0 1.6 ± 2.0 3.0 ± 2.9 -23.1 ± 13.8 LL006B4FN29 -13 159 0 -0.2 ± 0.1 1.8 ± 2.6 -28.6 ± 17.0 LL00685FN30 -3 95 0 1.6 ± 2.0 1.8 ± 2.6 -19.3 ± 16.0 LL00686FN31 -8 75 0 0.4 ± 1.2 2.2 ± 2.7 -28.6 ± 17.0 LL00687FN32 -8 224 0 -0.2 ± 0.1 0.5 ± 2.1 -21.4 ± 15.8 LL00688FN33 2 175 0 0.4 ± 1.2 1.3 ± 2.4 -30.4 ± 18.1 LL00689FN34 -3 115 0 -0.2 ± 0.1 -0.4 ± 1.7 -24.1 ± 18.9 LL00690'FN35 7 58 0 -0.2 ± 0.1 -1.2 ± 1.3 -38.9 ± 22.0 LL00691FN36 2 22 0 -0.2 ± 0.1 2.2 ± 2.7 -24.5 ± 15.3 LL00692FN37 2 18 0 -0.2 ± 0.1 0.5 ± 2.1 -28.4 ± 19.8 LL00693

FN38 7 103 0 -0.2 ± 0.1 3.9 ± 3.2 -21.7 ± 20.6 LL00694FN39 -3 179 0 1.0 ± 1.7 0.9 ± 2.3 -22.9 ± 19.0 LL00695FN40 -3 103 0 0.4 ± 1.2 0.5 ± 2.1 -30.4 ± 18.1 LL00696FN41 2 30 0 0.4 ± 1.2 -1.2 ± 1.3 -9.0 ± 12.9 LL00697FN42 12 139 0 0.4 ± 1.2 1.3 ± 2.4 -8.4 ± 14.8 LL00698

FN43 -3 139 0 -0.2 ± 0.1 1.8 ± 2.6 -20.3 ± 14.1 LL00699FN44 -3 1 91 1 0.4 ± 1.2 0.5 ± 2.1 -9.4 ± 13.4 LL00700

C-1 1-14

Page 73: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. :>H-4939-R-97, Facility Close-o"AndTermination Surv, Camp-- ilmer, NJ, 1 Jul - 20 Dec 97

.. Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units >) dpm/100cmA2 dpmrlOOcmA2 uRlhr dpm/lOOcmA2 +/-2 sigma Number

(Bkgd=>) 5 0.0 to 0.34 0.89 to 1.41 7.86 *to 7.9(MDA>) 52 284 - 2.44 " 2.39 49.02FN45. 2 10 1 1.0 t 1.7 1.3 ± 2.4 -20.3 ± 15.9 LL00701FN46 -8 119 1 -0.2 t 0.1 0.9 ± 2.3 -24.1 ± 18.9 LL00702FN47 -8 111 1 0.4 ± 1.2 0.9 ± 2.3 -14.8 ± 17.6 LL00703FN48 17 62 0 1.0 ± 1.7 2.2 ± 2.7 -8.4 ± 14.8 LL00704FN49 -8 38 1 -0.2 ± 0.1 -1.7 ± 0.9 -11.2 ± 14.5 LL00705FN50 -3 -42 1 0.4 ± 1.2 0.9 ± 2.3 -18.3 ± 15.2 LL00706F01 -8 71 1 0.4 ± 1.2 0.0 ± 1.9 -15.2 ± 10.6 LL00707F02 -8 252 1 0.4 ± 1.2 0.5 ± 2.1 -11.2 ± 9.9 LL00708F03 -8 71 1 -0.2 ± 0.1 3.9 ± 3.2 -15.0 ± 11.1 LL00709F04 -8 107 1 -0.2 ± 0.1 0.0 ± 1.9 -10.2 ± 9.0 LL00710F05 2 2 1 -0.2 ± 0.1 0.9 ± 2.3 -9.9 * 10.8 LL00711F06 12 75 1 4.0 z-3.1 4.8 ± 3.4 -10.5 ± 10.0 LL00712F07 -8 171 1 -0.2 ± 0.1 -0.8 ± 1.5 -12.2 ± 10.2 LL00713FOB 2 79 1 -0.2 ± 0.1 1.3 ± 2.4 -12.2 ± 12.5 LL00714F09 12 155 1 -0.2 ± 0.1 1.3 ± 2.4 -17.4 ± 14.5 LL00715FOll 12 151 1 6.9 + 4.0 10.3 ± 4.5 1.7 ± 11.1 LL00717F012 -8 95. 1 1.6 ± 2.0 0.5 ± 2.1 -17.7 * 13.0 LL00718F013 -8 135 0 0.4 ± 1.2 -0.4 ± 1.7 -5.4 ± 12.3 LL00719F014 -3 79 0 -0.2 + 0.1 1.8 ± 2.6 -14.8 ± 14.1 LL00720F015 -8 183 0 0.4 ± 1.2 -1.7 ± 0.9 -17.0 ± 11.9 LL00721F016 2 123 0 -0.2 ± 0.1 0.9 ± 2.3 -17.9 ± 11.2 LL00722F017 2 183 0 0.4 ± 1.2 3.5 ± 3.1 -19.3 ± 15.1 LL00723F018 -13 87 0 1.0 ± 1.7 1.3 ± 2.4 -12.4 ± 11.0, LL00724FO19 -13 179 0 0.4 ± 1.2 1.3 ± 2.4 -12.8 ± 13.0 LL00725F020 -3 143 0 0.4 ±. 1.2 0.0 ± 1.9 -17.7 ± 13.0 LL00726F021 -8 163 0 -0.2 ± 0.1 3.0 ± 2.9 59.7 ± 23.1 LL00727F022 -3 191 0 -0.2 ± 0.1 0.0 ± 1.9 -7.8 ± 9.3 - LL00728-F023 7 62 0 -0.2 ± 0.1 -1.2 ± 1.3 -11.0 ± 12.1 LL00729F024 -8 75 0 -0.2 ± 0.1 -0.8 ± 1.5 -32.3 ± 13.3 LL00730F025 -8 187 0 1.0 ± 1.7 0.5 ± 2.1 -18.5 ± 13.6 LL00731F026 2 167 0 -0.2 ± 0.1 0.9 ± 2.3 -20.3 ± 12.0 LL00732F027 2 151 0 0.4 ± 1.2 1.8 ± 2.6 -6.9 ± 12.1 LL00733F028 -13 131 0 0.4 ± 1.2 -1.2 ± 1.3 -8.7 ± 8.9 LL00734F029 2 91 0 0.4 ± 1.2 0.9 * 2.3 -16.1 ± 10.1 LL00735F030 -13 91 0 0.4 -± 1.2 1.8 ± 2.6 -21.3 ± 14.8 LL00736F031 7 175 0. 1.6 ± 2.0 2.2 ± 2.7 -12.8 ± 13.0 LL00737F032 2 123 0 -0.2 ± 0.1 -0.4 ± 1.7 -11.2 ± 9.9 LL00738F033 -3. 95 0 1.0 ± 1.7 3.5 ± 3.1 -4.4 ± 10.0 LL00739F034,- 7 .. 123 0 -0.2 ± 0.1 0.5 ± 2.1 -15.2 ± 7.8 LL00740F035 -13 107 0 0.4 ± 1.2 0.0 ± 1.9 -21.1 ± 11.9 LL00741F036 -8 183 -1 -0.2 ± 0.1 0.9 ± 2.3 -18.3 t 15.2 LL00742F037 -3 -2 0 1.0 ± 1.7 1.8 ± 2.6 -27.6 ± 12.4 LL00743F038 -3 143 0 -0.2 ± 0.1 1.8 ± 2.6 -20.3 ± 13.4 LL00744F039 -8 143 0 1.0 ± 1.7 0.0 ± 1.9 -22.3 ± 14.7 LL00745F040 -3 131 0 -0.2 ± 0.1 1.3 ± 2.4 -16.8 t 13.1 LL00746F041 23 87 0 -0.2 ± 0.1 0.9 ± 2.3 -21.0 ± 11.3 LL00747F042 2 159 0 -0.2 ± 0.1 0.0 ± 1.9 -4.3 ± 9.7 LL00748F043 23 83 0 -0.2 ± 0.1 -0.4 ± 1.7 -4.4 ± 14.0 LL00749F044 2 58 1 1.6 ± 2.0 0.0 ± 1.9 -14.5 ± .10.7 LL00750FO45 -13 66 0 -0.2 t 0.1 3.5 ± 3.1 -16.2 ± 12.0 LL00751

C-11-15

Page 74: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 22"-M-4939-R-97, Facility Close-o)'-andTermination Surv, Caml lmer, NJ, 1 Jul -20 Dec 97 :

Camo Kilmer RUILDING 1072 ROOM 9..... Kilmer-..... DI N 1072... ... ... ...Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpnI100cmA2 dpm/l100cmA2 uRPhr dpm/1OOcmA2 +/-2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9(MDA >) 52 284 - 2.44 * 2.39 49.02 "F046 -3 135 0 -0.2 ± 0.1 2.2 ± 2.7 -9.5 ± 12.3 LL00752F047 -13 91 0 -0.2 ± 0.1 0.5 ± 2.1 -11.5 ± 10.2 LL00753F048 2 115 0 -0.2 ± 0.1 1.3 ± 2.4 -6.7 ± 9.5 LL00754F049 -8 111 1 -0.2 ± 0.1 0.0 ± 1.9 -6.9 ± 10.8 LL00755F050 2 115 0 0.4 ± 1.2 0.0 ± 1.9 -8.8 ± 11.4 LL00756FP1 -8 115 1 -0.2 ± 0.1 -0.4 * 1.7 -12.4 ± 11.0 LL00757FP2 -3 95 1 -0.2 ± 0.1 0.0 ± 1.9 -8.6 ± 10.2 LL00758FP3 2 260 1 -0.2 ± 0.1 2.6 ± 2.8 -12.1 ± 8.0 LL00759FP4 -8 147 0 -0.2 ± 0.1 0.9 ± 2.3 -10.2 ± 10.4 LL00760FP5 -8 66 0 -0.2 ± 0.1 -0.4 ± 1.7 -10.5 ± 9.3 LL00761FP6 -8 14 0 1.0 ± 1.7 0.5 ± 2.1 -8.4 ± 9.3 LL00762FP7 2 111 0 -0.2 ± 0.1 1.8 ± 2.6 -15.0 ± 11.1 LL00763FP8 •-3 14 0 -0.3 ± 0.2 -0.3 ± 2.5 -15.0 ± 11.1 LL00764FP9 2 175 0 0.3 ± 1.3 4.3 ± 3.9 -14.6 ± 12.2 LL00765FPIO 2 66 1 0.3 ± 1.3 2.8 ± 3.5 -1.0 ± 12.8 LL00766FP11 -8 199 0 -0.3 ± 0.2 0.2 ± 2.7 -7.3 ± 10.4 LL00767FP12 -3 304 0 -0.3 ± 0.2 D0.7 ± 2.9 -14.2 ± 13.5 LL00768FP13 12 46 0 0.3 ± 1.3 1.7 ± 3.2 -12.9 ± 10.1 LL00769FP14 -3 79 0 -0.3 :t 0.2 2.2 ± 3.3 -10.7 ± 13.9 LL00770FP15 17 187 0 -0.3 ± 0.2 -0.8 ± 2.3 -6.6 ± 13.2 LL00771FP16 2 211 0 0.3 ± 1.3 1.7 ± 3.2 -15.9 ± 13.2 LL00772FP17 2 38 0 0.3 ± 1.3 1.2 ± 3.0 -14.1 ± 11.7 LL00773FP18 -8 191 0 0.3 ± 1.3 -0.3 ± .2.5 -17.9 ± 11.2 LL00774FP19 -3 50 0 -0.3 ± 0.2 0.7 ± 2.9 -14.2 ± 9.9 LL00775FP20 7 127 0 1.6 ± 2.2 1.7 ± 3.2 -8.7 ± 12.4 LL00776FP2.1 2 131 0 -0.3 ± 0.2 -0.3 ± 2.5 -8.7 ± 9.5 LL00777FP22 -8 119 0 -0.3 ± 0.2 .7.8 ± 4.7 -9.5 ± 11.3 LL00778FP23 7 135 0 0.3 ± 1.3 3.3 ± 3.6 -6.7 ± 10.5 LL00779FP24 -3 155 0 0.3 ± 1.3 1.2 ± 3.0 -12.4 ± 11.0 LL00780FP25 -8 50 0 0.3 ± 1.3 3.8 1 3.7 -22.8 ± 11.7 LL00781FP26 2 147 0 1.0 ± 1.8 0.2 + 2.7 -17.3 ± 10.8 LL00782FP27 2 167 0 - 3.6 ± 3.2 9.8 ± 5.1 -11.9 ± 10.6 LL00783FP28 17 66 0 -0.3 ± 0.2 3.8 * 3.7 -9.5 ± 12.3 LL00784FP29 -3 103 0 1.0 ± 1.8 -1.8 + 1.8 -17.4 ± 10.3 LL00785FP30 -13 187 0 1.0 ± 1.8 3.3 ± 3.6 -14.5 ± 10.7 LL00786FP31 -8 -30 0 4.3 ± 3.4 9.8 + 5.1 -13.0 ± 12.4 LL00787FP32 -3 66 0 -0.3 ± 0.2 1.2 + 3.0 -10.9 ± 11.1 LL00788FP33 -8 167 0 0.3 ± 1.3 1.7 : 3.2 -18.5 + 13.6 LL00789FP34 -3 179 0 0.3 ± 1.3 0.2 + 2.7 -15.4 ± 12.1 LL00790FP35 -3 22 0 0.3 ± 1.3 3.3 ± 3.6 -9.5 ± .12.3 LL00791FP36 12 38 0 1.0 ± 1.8 -1.3 ± 2.1 -17.8 ± 11.8 LL00792FP37 -3 62 0 -0.3 ± 0.2 -1.8 ± 1.8 -14.1 ± 11.7 LL00793FP38 -3 -6 0 0.3 ± 1.3 3.3 ± 3.6 -13.5 ± 10.0 LL00794FP39 23 139 1 -0.3 ± 0.2 2.2 ± 3.3 -4.5 ± 11.9 LL00795FP40 2 107 0 0.3 ± 1.3 0.7 ± 2.9 -22.4 ± 15.6 LL00796FP41 -8 151 1 0.3 ± 1.3 2.2 ± 3.3 -9.4 ± 13.4 LL00797FP42 -8 127 0 -0.3 ± 0.2 0.7 ± 2.9 -2.5 ± 9.7 LL00798FP43 -13 228 0 1.0 ± 1.8 -0.3 ± 2.5 -26.3 ± 14.2 LL00799FP44 -13 71 0 1.0 ± 1.8 1.2 ± 3.0 -17.7 ± 13.0 LL00800FP45 2 155 0 0.3 ± 1.3 1.2 ± 3.0 -13.3 : 11.8 LL00801

C-11-16

Page 75: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. ,•NH) -4939-R-97, Facility Close-c'-andTermination Surv, Caml- ... ilmer, NJ, 1 Jul - 20 Dec 97

..... _Camp Kilmer, BUILDING 1072 ROOM 9 ..Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units =>) dpm/100cmA2 dpmrlOOcmA2 uRlhr dpmnlOOcMAn2 +/-2 sigma Number(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9(MDA =>) 52 284 - 2.44" 2.39 49.02 . ....FP46 -8 151 0 0.3 + 1.3 -0.8 : 2.3 -10.6 :110.8 LL00802FP47 -13 50 0 -0.3 + 0.2 0.2 ± 2.7 -11.9 ± 10.6 LL00803FP48 -3 46 0 -0.3 ± 0.2 0.7 ± 2.9 -14.5 ± 10.7 LL00804FP49 7 175 0 1.0 ± 1.8 0.7 ± 2.9 -6.4 ± 10.1 LL00805FP50 -3 131 -1 -0.3 ± 0.2 -1.3 ± 2.1 -11.8 ± 12.0 LL00806QAA NA N/A N/A 0.3 ± 1.3 -0.8 ± 2.3 -4.1 ± 6.5 LL00807FQ1 7 127 1 -0.3 ± 0.2 1.2 ± 3.0 -11.8 ± 9.8 LL00808F02 7 26 1 -0.3 + 0.2 1.2 ± 3.0 -9.5 ± 10.5 LL00809F03 -3 135 1 -0.3 ± 0.2 -1.8 ± 1.8 -14.6 t 9.1 LL00810F04 7 187 1 3.0 ± 2.9 -0.3 ± 2.5 -11.2 ± 10.7 LL00811FQ5 -13 58 0 0.3 ± 1.3 -0.8 + 2.3 -9.9 ± 10.8 LL00812FQ6 -8 159 0 1.0 ± 1.8 1.2 ± 3.0 -7.4 ± 8.8 LL00813FQ7 7 71 0 -0.3 ± 0.2 -0.3 ± 2.5 -15.9 ± 10.5 LL00814FOB 2 6 0 -0.3 ± 0.2 1.2 ± 3.0 -5.4 ± 10.6 LL00815FQ9 2 58 0 -0.3 ± 0.2 -0.3 ± 2.5 -15.3 ± 12.7 LL00816FQ10 2 2 1 -0.3 ± 0.2 0.2 ± 2.7 -19.4 ± 13.5 LL00817FQ11 -8 30 0 0.3 ± 1.3 0.7 ± 2.9 -12.2 ± 12.5 LL00818F012 -8 91" 0 -0.3 ± 0.2 1.7 ± 3.2 -9.9 ± 10.8 LL00819FQ13 -3 -22 0 0.3 ± 1.3 1.2 ± 3.0 -13.3 ± 11.8 LL00820FQ14 7 62 1 0.3 ± 1.3 0.2 ± 2.7 -12.5 ± 11.9 LL00821FQ15 12 38 0 0.3 ± 1.3 1.2 ± 3.0 -15.6 ± 11.5 LL00822FQ16 -3 -54 0 0.3 ± 1.3 2.2 ± 3.3 -16.2 ± 12.0 LL00823F017 -3 -14 0 1.0 ± 1.8 2.8 ± 3.5 -12.6 * 10.5 LL00824FQ18 -13 115 0 -0.3 ± 0.2 -1.3 ± 2.1 -15.9 ± 10.5 LL00825F019 -8 71 0 -0.3 ± 0.2 -0.8 ± 2.3 -13.1 ± 9.7 LL00826F020 -13 38 0 -0.3 ± 0.2 0.7 ± 2.9 -17.0 ± 11.9 LL00827FQ21 -13 135 0 -0.3 ± 0.2 1.2 ± 3.0 -4.7 ± 10.7 LL00828FQ22 -8 -6 0 -0.3 ± 0.2 0.2 ± 2.7 -6.5 ± 9.2 LL00829F023 2 203 0 -0.3 ± 0.2 0.7 ± 2.9 -11.7 ± 9.2 LL00830F024 2 18 0 2.3 ± 2.6 0.7 ± 2.9 -10.2 ± 9.0 LL00831FQ25 -8 62 1 3.0 ± 2.9 1.7 ± 3.2 -11.2 ± 10.7 LL00832FQ26 -3 -42 0 -0.3 ± 0.2 -0.8 ± 2.3 -11.2 ± 10.7 LL00833F027 2 62 0 -0.3 ± 0.2 -0.3 ± 2.5 -9.3 ± 9.4 LL00834FQ28 -8 79 0 -0.3 ± 0.2 2.2 ± 3.3 -21.0 ± 10.8 LL00835FQ29 2 171 1 -0.3 ± 0.2 1.2 ± 3.0 -13.3 ± 10.4 LL00836F030 -8 75 0 -0.3 ± 0.2 -1.8 ± 1.8 -19.5 ± 10.5 LL00837.FQ31 -8 -46 0 -0.3 ± 0.2 0.7 ± 2.9 33.9 ± 17.8 LL00838F032 7 111 -1 -0.3 ± 0.2 0.2 ± 2.7 -15.0 ± 9.4 LL00839F033 7 195 0 0.3 ± 1.3 -0.8 ± 2.3 -16.5 ± 10.9 LL00840FQ34 -3 54 0 -0.3 ± 0.2 -1.8 ± 1.8 -13.5 ± 10.0 LL00841F035 2 14 0 -0.3 ± 0.2 2.2 ± 3.3 -13.3 ± 10.4 LL00842F036 -3 71 1 -0.3 ± 0.2 -2.3 ± 1.5 -6.9 ± 13.7 LL00843F037 -3 79 1 1.0 ± 1.8 2.2 ± 3.3 -14.5 ± 10.7 LL00844FQ38 -13 -6 1 1.6 ± 2.2 -0.8 ± 2.3 12.9 ± 12.2 LL00845FQ39 -3 95 1 0.3 ± 1.3 -0.3 ± 2.5 -7.4 ± 11.6 LL00846FQ40 -13 91 0 -0.3 ± 0.2 2.2 ± 3.3 -16.2 ± 12.0 LL00847FQ41 -8 -34 0 1.0 ± 1.8 -0.8 ± 2.3 -21.1 ± 12.6 LL00848FQ42 -3 18 1 0.3 ± 1.3 1.2 ± 3.0 -13.5 ± 8.9 LL00849F043 7 -91 0 -0.3 ± 0.2 -0.8 ± 2.3 -12.7 ± 9.4 LL00850FQ44 -3 .115 0 -0.3 ± 0.2 0.2 ± 2.7 -11.8 ± 12.0 LL00851

C-1 1-17

Page 76: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2-"--H-4939-R-97, Facility Close-o"'-andTermination Surv, Camn .imer, NJ, I Jul - 20 Dec 97 )

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring I Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpmlO00cm^2 dpm/l00cmA2 uRJhr dprmlO00cmA2 41-2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA >) 52 284 - 2.44 * 2.39 49.02 *FQ45 -3 111 0 -0.3 ± 0.2 2.8 ± 3.5 -12.9 ± 10.1 LL00852FQ46 12 183 0 -0.3 ± 0.2 -1.8 ± 1.8 -13.6 ± 11.3 LL00853FQ47 12 30 1 0.3 ± 1.3 0.2 ± 2.7 -12.2 ± 10.2 LL00854

FQ48 -13 207 0 -0.3 ± 0.2 -1.8 ± 1.8 -2.9 ± 9.3 LL00855FQ49 -3 6 1 0.3 ± 1.3 -0.8 ± 2.3 -10.5 ± 9.3 LL00856FQ50 .- 13 -139 1 -0.3 ± 0.2 0.7 ± 2.9 -20.4 ± 18.1 LL00857FRI 12 -10 0 -0.3 ± 0.2 -0.8 ± 2.3 -14.2 ± 13.5 LL00858FR2 -8 79 0 -0.3 ± 0.2 1.7 ± 3.2 -12.5 ± 11.9 LL00859FR3 23 -10 0 1.0 ± 1.8 1.7 ± 3.2 -2.9 ± 11.3 LL00860FR4 -8 119 0 -0.1 + 0.1 1.5 t 2.9 -13.5 ± 10.0 LL00861FR5 -13 -6 0 0.5 ± 1.2 2.7 ± 3.0 -13.6 ± 12.9 LL00862FR6 -8 71 0 1.1 ± 1.7 1.4 ± 2.5 -13.8 ± 12.3 LL00863FR7 7 -6 0 -0.1 ± 0.1 0.6 ± 2.6 -14.2 ± 13.5 LL00864FR8 -3 66 1 -0.1 ± 0.1 1.8 ± 2.7 -5.7 ± 15.2 LL00865FR9 23 -38 0 -0.1 ± 0.1 1.4 ± 2.5 -29.2 ± 15.8. LL00866FR10 2 -6 1 0.5 ± 1.2 0.6 ± 2.6 -18.0 ± 18.4 LL00867FRI1 -3 58 0 -0.1 ± 0.1 -0.5. ± 1.8 -15.5 ± 14.7 LL00868FR12 -3 -6 0 -0.1 ± 0.1 1.0 ± 2.3 -22.6 ± 16.6 LL00869FR13, -13 -6 0 0.5 ± 1.2 0.2 ± 2.4 -20.4 ± 19.3 LL00870FR14. 12 91 0 1.1 ± 1.7 0.4 ± 2.2 -18.5 ± 12.9 LL00871FR15 7 -71 0 1.1 ± 1.7 2.3 ± 2.8 -9.3 ;t. 16.3 LL00872FR16 7 -87 0 1.1 ± 1.7 2.9 ± 3.2 -19.4 ± 12.2 LL00873FR17 2 14 0 -0.1 ± 0.1 0.0. ± 2.0 -12.7 ± 15.1 LL00874FR18' -3 195 1 -0.1 + 0.1 1.0 ± 2.3 -18.5 ± 12.9 LL00875FR19. 2 159 0 0.5 ± 1.2 -0.3 ± 2.2 -12.3 ± 16.0 LL00876FR20- -8 -22 1 0.5 ± 1.2 0.9 ± 2.4 -16.6 ± 13.8 LL00877FR21 -3 2 0 1.7 ± 2.1 1.0 ± 2.3 -18.1 ± 17.2 LL00878FR22 -13 30 0 -0.1 ± 0.1 -0.3 ± 2.2 -24.4 + 20.3 LL00879FR23 2 -66 0 -0.1 ± 0.1 0.9 ± 2.4 -24.5 ± 15.3 LL00880FR24 -8 103 0 -0.1 ± 0.1 1.0 ± 2.3 -24.5 ± 15.3 LL00881FR25 -13 195 1 0.5 ± 1.2 0.2 ± 2.4 -18.5 ± 13.6 LL00882FR26 2 111 1 -0.1 ± 0.1 -1.4 ± 1.3 -15.9 ± 13.2 LL00883

FR27 -3 167 0 -0.1 ± 0.1 0.5 ± 2.2 -11.1 ± 13.2 LL00884

FR28 -3 187 0 0.5 ± 1.2 0.2 ± 2.4 -24.5 ± 15.3 LL00885FR29 2 191 0 0.5 ± 1.2 0.9 t 2.4 -20.3 ± 13.4 LL00886FR30 2 54 0 -0.1 ± 0.1 2.8 ± 2.9 -21.3 ± 14.8 LL00887FR31 2 -75 0 0.5 ± 1.2 0.6 ± 2.6 -20.3 ± 15.0 LL00888FR32 12 50 0 0.5 ± 1.2 1.3 ± 2.6 -22.2 ± 13.9 LL00889FR33 2 58 0 0.5 ± 1.2 -0.4 ± 1.8 -26.6 ± 15.1 LL00890FR34 2 -34 0 0.5 ± 1.2 -1.6 ± 1.6 -21.5 ± 17.9 LL00891FR35 2 123 0 -0.1 ± 0.1 0.0 ± 2.0 -16.1 ± 16.4 LL00892FR36 2 22 0 -0.1 ± 0.1 1.0 ± 2.3 -19.3 ± 14.3 LL00893FR37 7 163 0 -0.1 ± 0.1 -0.3 ± 2.2 -20.3 ± 15.9 LL00894FR38 -3 211 0 0.5 ± 1.2 0.4 ± 2.2 -19.3 ± 15.1 LL00895FR39 2 147 0 -0.1 ± 0.1 1.4 ± 2.5 -25.3 ± 14.3 LL00896FR40 7 115 0 0.5 ± 1.2 0.2 ± 2.4 -25.7 ± 12.6 LL00897FR41 7 2 0. -0.1 ± 0.1 -0.5 ± 1.8 -9.0 ± 12.9 LL00898

FR42 17 50 0 -0.1 ± 0.1 2.3 ± 2.8 -13.7 ± 9.6 LL00899FR43 2 58 0 -0.1 ± 0.1 -0.3 ± 2.2 -9.2 ± 10.9 LL00900

FR44 -8 -10 0 1.7 ± 2.0 2.7 ± 3.0 -20.3 ± 14.1 LL00901

C-11-18

Page 77: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2--4H-4939-R-97, Facility Close-o<•ndTermination Surv, Camp Llmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units =>) dprnl1 0DcmA2 dprn/1 OcmA2 uRPhr dprn/1 00cmA2 +1- 2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA >) 52 284 - 2.44 * 2.39 " 49.02

FR45 7 58 0 -0.1 ± 0.1 0.1 ± 2.0 -16.9 : 12.5 LL00902FR46 12 22 0 -0.1 ± 0.1 -2.1 ± 1.4 -16.3 ± 15.5 LL00903FR47 -13 22 0 -0.1 ± 0.1 -0.5 ± 1.8 -9.8 ± 19.3 LL00904FR48 2 103 0 -0.1 ± 0.1 1.0 ± 2.3 -23.1 ± 20.5 LL00905FR49 -13 79 0 -0.1 ± 0.1 -1.2 ± 1.8 -10.8 ± 17.1 LL00906FR50 -8 30 0 -0.1 ± 0.1 -1.8 + 1.0 -19.3 ± 14.3 LL00907QA NIA N/A N/A 0.5. ± 1.2 0.1. ± 2.0 -0.9 ± 6.9 LL00908WAIA -3 -228 1 -0.1 ± 0.1 -2.1 ± 1.4 -5.0 ± 7.2 LL00909WA2A 7 -244 1 0.5 ± 1.2 0.9 ± 2.4 1.6 ± 7.7 LL00910WA3A -8 -272 1 -0.1 ± 0.1 0.1 ± 2.0 17.3 ± 9.3 LL00911WA4A -3 -179 1 -0.1 ± 0.1 -0.7 ± 2.1 -3.8 ± 7.5 LL00912WASA -8 -240 0 -0.1 ± 0.1 1.8 ± 2.7 21.6 ± 9.8 LL00913.WA6A 7 -151 0 -0.1 + 0.1 -1.7 ± 1.0 -4.6 ± 7.2 LL00914WA7A -3 -187 0 -0.1 ± 0.1 -2.1 ± 1.4 -5.6 ± 7.3 LL00915WABA -3 -284 0 -0.1 ± 0.1 -0.9 ± 1.6 -5.1 ± 7.3 LL00916WA9A 7 -248 0 -0.1 ± 0.1 1.0 ± 2.3 -5.7 ± 7.4 LL00917WA10A -3 -268 0 -0.1 ± 0.1 -0.7 ± 2.1 28.5 ± 10.6 LL00918WA11A -3 -220 0 0.5 ± 1.2 -0.5 ± 1.8 -5.1 ± 7.3 LL00919WA12A -3 -300 0 -0.1 ± 0.1 2.8 ± 2.9 2.7 ± 8.4 LL00920WA13A -8 -344 0 0.5 ± 1.2 0.2 ± 2.4 -6.5 ± 7.1 LL00921WA14A 2 -348 -1 -0.1 ± 0.1 -0.9 ± 1.6 -5.2 ± 8.1 LL00922WA15A 17 -220 -1 0.5 ± 1.2 0.5 ± 2.2 -8.1 ± 7.1. LL00923WA16A 2 -187 -1 -0.1 ± 0.1 -0.7 ± 2.1 -5.6 ± 7.3 LL00924WA17A 7 -292 0 -0.1 ± 0.1 1.8 ± 2.7 -4.7 ± 7.4 LL00925WA18A 7 -183 -1 -0.1 ± 0.1 1.4 . 2.5 -2.4 ± 7.5 LL00926WA19A 7 -296 -1 0.5 ± 1.2 0.2 ± 2.4 -2.1 ± 8.1 LL00927WA20A 23 -191 0 -0.1 ± 0.1 0.4 1 2.2 -6.0 ± 6.7 LL00928WA21A -8 -268 0 -0.1 ± 0.1 0.5 ± 2.2 1.5 ± 7.4 LL00929WA22A -8 -195 0 -0.1 + 0.1 1.1 ± 2.7 -7.6 ± 7.2 LL00930WA23A -8 -304 0 -0.1 ± 0.1 -0.5 ± 1.8 -2.4 ± 7.6 LL00931WA24A -13 -304 0 -0.1 ± 0.1 0.1 ± 2.0 -1.1 ± 8.0 LL00932WA25A 12 -288 0 -0.1 ± 0.1 -0.7 ± 2.1 -5.6 ± 7.3 LL00933WA26A 17 -171 0 0.5 ± 1.2 -0.5 ± 1.8 -2.4 ± 7.6 LL00934WA27A -3 -232 -1 -0.1 ± 0.1 -0.8 ± 1.6 -8.2 ± 7.7 LL00935WA28A -3 -264 0 -0.1 ± 0.1 -0.3 ± 2.2 -6.9 ± 9.7 LL00936WA29A -13 -135 -1 0.5 ± 1.2 0.4 ± 2.2 -11.0 ± 12.1 LL00937WA30A -13 -260 -1 -0.1 ± 0.1 -1.2 ± 1.3 -9.7 ± 7.6 LL00938WA31A -8 -127 -1 -0.1 ± 0.1 -0.3 ± 2.2 -5.4 ± 7.7 LL00939WA32A -8 -320 0 -0.1 ± 0.1 0.9 ± 2.4 -7.1 ± 7.3 LL00940WA33A -3 -268 0 1.1 ± 1.7 -0.8 ± 1.6 -6.2 ± 7.4 LL00941WA34A -3 -207 0 -0.1 ± 0.1 0.2 ± 2.4 -2.5 ± 7.8 LL00942WA35A 2 -312 0 -0.1 ± 0.1 0.0 ± 2.0 -4.1 ± 7.3 LL00943WA36A -3 -324 -1 -0.1 ± 0.1 -0.4 ± 1.8 -5.0 ± 7.2 LL00944WA37A -3 -167 0 -0.1 ± 0.1 -1.2 ± 1.8 -3.3 ± 7.5 LL00945WA38A 12 -191 0 -0.1 ± 0.1 0.4 ± 2.2 -3.8 ± 7.5 LL00946WA39A 17 -252 0 -0.1 t 0.1 -0.8 ± 1.6 -5.5 ± 7.1 LL00947WA40A -8 -252 0 -0.1 ± 0.1 0.2 ± 2.4 -3.1 ± 8.1 LL00948WA41A -8 -252 0 -0.1 ± 0.1 0.4 ± 2.2 -7.0 ± 7.7 LL00949WA42A 2 -199 0 -0.1 ± 0.1 -1.2 ± 1.3 -5.5 ± 7.1 LL00950WA43A -13 -167 0 0.5 ± 1.2 -2.1 ± 1.4 -3.3 ± 7.5 LL00951

C-11-19

Page 78: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27ZMH-4939-R-97, Facility Close-out-.and

Termination Surv, Camro )lmer, NJ, 1 Jul - 20 Dec 97

.......... Camp Kilmer, BUILDING 1072 ROOM 9.Location Monitoring , . Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dprnlO00cmA2 dpm100OcmA2 uR/hr dpmnl00cmA2 +1- 2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA=>) 52 284 - 2.44 2.39. 49.02

WA44A 2 -167 0 -0.1 ± 0.1 -0.5 ± 1.8 -8.3 ± 6.9 LL00952

WA45A -3 -195 -1 -0.1 * 0.1 0.1 ± 2.0 3.1 ± 8.2 LL00953-

WA46A -8 -248. -1 -0.1 ± 0.1 -1.2 ± 1.8 8.7 ± 9.0 LL00954

WA47A -8 -308 0 -0.1 ± 0.1 0.4 ± .2.2 4.3 ± 8.2 LL00955

WA48A 2 -203 0 -0.1 ± 0.1 1.0 ± 2.3 1.2 ± 8.0 LL00956

WA49A 12 -155 0 -0.1 ± 0.1 2.0 ± 3.0 -4.2 ± 7.4 LL00957

WA50A -3 -252 0 0.5 ± 1.2 0.0 * 2.0 -6.1 ± 7.2 LL00958

WAIB 17 -284 1 0.5 ± 1.2 0.1 ± 2.0 2.1 t 8.0 LL00959

WA2B 23 -216 0 -0.1 ± 0.1 3.4 ± 3.4 -2.7 ± 7.3 LL00960

WA3B -3 -123 1 -0.1 ± 0.1 2.3 ± 2.9 23.0 ± 9.9 LL00961

WA4B -3 -224 1 -0.1 ± 0.1 0.5 ± 2.2 -1.4 ± 7.4 LL00962

WA5B -3 -272 1 -0.1 ± 0.1 -1.6 ± 1.6 -5.4 ± 6.9 LL00963

WA6B -8 -224 0 -0.1 ± 0.1 0.0 ± 2.0 -3.2 ± 7.4 LL00964

WA7B -8 -248 0 -0.1 ± 0.1 -1.2 ± 1.3 -1.0 ± 7.6 LL00965

WA8B 12 -365 . 0 -0.1 ± 0.1 -0.7 ± 2.1 -2.4 ± 7.6 LL00966

WA9B -3 -260 0 0.5 ± 1.2 0.4 ± 2.2 10.3 ± 9.4 LL00967

WA10B -3 -268 0 -0.1 .± 0.1 -0.4 ± 1.8 -7.0 ± 7.1 LL00968

WA11B -3 -167 .0 0.5 ± 1.2 -0.3 ± 2.2 -2.0 ± 7.7 LL00969

WA12B -3 -340 0 0.5 ±-1.2 -1.8 ± 1.0 -7.3 ± 7.4 LL00970

WA13B -8 -292 0 -0.1 ±. 0.1 -0.8 ± 1.6 -4.3 ± 7.6 LL00971

WA14B - -8 -187 -1 -0.1 ±10.1 -0.3 ± 2.2 -2.8 ± 7.4 LL00972

WA15B . -3 -211 0 -0.1 + 0.1 -0.5 ± 1.8 -6.4 ± 7.0 LL00973

WA16B - -3 -328 -1 -0.1 ± 0.1 0.1 ± 2.0 -6.3 ± 7.5 LL00974

WA17B - -3 -199 -1 -0.1 ± 0.1 -2.1 ± 1.4 -0.6 ± 8.0 LL00975

WAA18B- 2 -296 0 -0.1 ± 0.1 0.0 ± 2.0 -1.0 ± 7.6 LL00976

WA19B-- 17 -365 0 0.5 ±" 1.2 -0.8 ± 1.6 -0.6 ± 7.8 LL00977

WA20B --. -3 -187 0 -0.1 * 0.1 -0.7 ± 2.1 -4.7 ± 7.4 LL00978

WA21B 2 -332. -1 1.1 ± 1.7 1.3 ± 2.6 -4.2 ± 7.4 LL00979

WA22B -3 -199... 0 . 0.5 ± 1.2 0.1 ± 2.0 -4.6 ± 7.2 LL00980

WA23B -13 -288 0 -0.1 ± 0.1 -1.6 ± 1.6 -3.7 ± 7.3 LL00981

WA24B -8 -328.. 0 -0.1 * 0.1 0.9 ± 2.4 -5.6 ± 7.3 LL00982,

WA25B -13 -248 0 -0.1 ± 0.1 0.1 ± 2.0 -3.7 ± 7.3 LL00983

WA26B -8 -236 0 -0.1 * 0.1 -0.7 ± 2.1 -0.1 ± 8.1 LL00984-

WA27B " -13 -300 -1 0.5 ± .1.2 1.3 ± 2.6 -12.7 ± 15.1 LL00985

WA28B 2 -199 0 -0.1 : .0.1 -0.8 ± 1.6 -21.1 ± 12.6 LL00986

WA29B -8 -252 . -1 -0.1 ± 0.1 0.2 ± 2.4 -12.1 + 11.5 LL00987

WA30B -8 -264 -1 -0.1 ±. 0.1 -0.5 ± 1.8 -7.7 ± 8.5 LL00988

WA31B . -3 -183 -1 -0.1 + 0.1 -0.8 ± 1.6 -7.0 ± 7.7 LL00989

WA32B -3 -211 0 -0.1 ± 0.1 -0.7 ± 2.1 -4.7 ± 8.2 LL00990,

WA33B -3 -183 .0 -0.1. ± 0.1 -0.5 ± 1.8 -7.7 ± 7.8 LL00991.

WA34B 2. -236 .. 0 -0.1 ± 0.1 0.5 ± 2.2 -4.5 * 8.0 LL00992

WA35B" 2 -203 0 -0.1 ± 0.1 1.1 ± .2.7 -5.4 ± 7.7 LL00993

WA36B ..-13 -296 0 -0.1 ± 0.1 2.7 ± 3.0 -5.3 ± 7.5 LL009941A37B -3 -260 0 -0.1 ± 0.1 -0.4 ± 1.8 -4.4 ± 6.9 LL00995

WA38B 2 .- 207 -1 -0.1 .± 0.1 0.2 ± 2.4 -13.1 ± 10.9 LL00996

WA39B 2 -244 -1 -0.1. ± 0.1 0.0 t 2.0 5.6 ± 9.8 LL00997

WA40B -3 -199 0 0.5 ± 1.2 0.5 ± 2.2 -6.3 ± 7.5 LL00998

WA41B -3 -216 0 0.5 ±. 1.2 -1.2 ± 1.8. -4.2 ± 7.4 LL00999

WA42B -8 -280 0 -0.1 ± 0.1 2.3 ± 2.9 -5.5 ± 7.8 LL01000

WA43B -3 -236 0 -0.1 ± 0.1 -0.8 ± 1.6 -4.8 ± 7.5 LL01001.

C-11-20

Page 79: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No.. <H-4939-R-97, Facility Close-c andTermination Surv, Camp .,ilmer, NJ, 1 Jul - 20 Dec 97

".. . ... .Camp Kilmer, BUILDING 1072 ROOM 9Location. Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units >) dpmn/100cmA2 dpmrlO00=cA2 uR/hr dpm/1OOcmA2 +/-2 sigma Number(Bkgd>) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9(MDA>) 52 284 - - 2.44 2.39 49.02WA44B 2 -163 -1 0.5 t 1.2 -0.3 + 2.2 -7.6 * 7.2 LL01002WA45B 2 -191 0 0.5 ± 1.2 0.0 ± 2.0 -1.9 ± 7.4 LL01003WA46B -8 -312 -1 -0.1 ± 0.1 -0.8 ± 1.6 -2.9 ± 7.8 LL01004WA47B -13 -264 -1 -0.1 ± 0.1 -2.1 t 1.4 -2.4 ± 7.6 LL01005WA48B -3 -236 0 0.5 t 1.2 -0.9 ± 1.6 -7.1 t 7.3 LL01006WA49B -3 -224 0 0.5- ± 1.2 -1.2 ± 1.3 -4.8 ± 6.8 LL01007WA50B 2 -207 -1 -0.1- ± 0.1 -1.6 t 1.6 -5.9 ± 7.6 LL01008.WAIC -3 -171 1 0.5 ± 1.2 1.3 t. 2.6 36.0 + 10.8 LLO1009WA2C 2 -87 1 -0.1 ± 0.1 -0.4 ± 1.8 -1.9 ± 7.4 LL01010WA3C -3 -187 1 -0.1 ± 0.1 -1.2 ± 1.8 -3.4 ± 7.7 LL01011WA4C -8 -107 0 -0.1 ± 0.1 0.4 ± 2.2 -4.5 ± 7.0 LL01012.WA5C 12 -324 1 -0.1+ 0.1 -0.8 ± 1.6 -2.3 ± 7.3 LL01013WA6C -8 -54 0 -0.1 ± 0.1 -1.2 ± 1.8 -9.2 ± 6.8 LL01014WA7C -13 -199-- 0 -0.1 ±0.1 41.8 ± 1.0 -1.9 ± 7.4 LL01015WA8C 7 -175 0 -0.1 ± 0.1 -0.4 ± 1.8 -7.2 ± 8.6 LL01016WA9C 7 -248 0 -0.1 ± 0.1 -0.3 ± 2.2 -4.3 ± 7.6 LL01017WA10C -13 -248 0 0.5 + 1.2 3.2 ± 3.1 -2.1 ± 8.2 LL01018WAl1C -13 -252 0 0.5 ± 1.2 -0.8 ± 1.6 -6.2 ± 6.8 LL01019WA12C -13 -304 -1 0.5 - 1.2 -0.7 ± 2.1 -2.4 ± 7.5 LL01020,WA13C -13 -248 -1 1.1 -t 1.7 1.3 t 2.6 -3.2 ± 7.4 LL01021WA14C -13 -260 -1 -0.1 - 0.1 1.0 ± 2.3 *-3.1 t 7.0 LL01022WA15C -8 -139 0 -0.1 ± 0.1 -0.7 ± 2.1 -9.0 ± 7.0 LL01023WA16C -3 -324 -1 -0.1 0.1 0.0 ± 2.0. 49.4 ± 13.1 LL01024WA17C -13 -236 0 -0.1 ± 0.1 0.1 * 2.0 -4.2 ± 7.4 LL01025WA18C 7 -171 -1 -0.1 ±. 0.1 0.6 ± 2.6 1.2 ± 7.9 LL01026WA19C 7 -175 0 -0.1 + 0.1 0.0 ± 2.0 63.9 ± 13.0 LL01027WA20C -13 -236 0 -0.1 ± 0.1 -0.4 ± 1.8 16.3 ± 9.4 LL01028WA21C -13 -224 -1 1.7 ± 2.1 0.2 ±*2.4 -3.4 ± 7.7 LL01029WA22C -3 -167 -1 -0.1 ± 0.1 0.9 ± 2.4 -1.5 ± 7.6 LL01030WA23C 7 -220 -1 -0.1 * 0.1 -0.4 ± 1.8 15.6 ± 9.9 LL01031WA24C -3 -26 -1 0.5 ± 1.2 -0.7 ± 2.1 -8.4 ± 7.9 LL01032WA25C -8 -131 0 0.5 ± 1.2 -0.9 ± 1.6 2.6 ± 8.2 LL01033WA26C -8 -312 -1 -0.1 ± 0.1 1.4 ± 2.5 -7.0 ±-7.1 LL01034WA27C -3 -191 0 0.5 ± 1.2 0.6 ± 2.6 -6.5 9.2 LL01035WA28C -8 -296 0 1.1 ± 1.7 1.3 ± 2.6 -...- 11.2 t 10.7 LL01036WA29C 2 -211 0 -0.1 ± 0.1 -0.4 ± 1.8 a-7.8 ± 11.1 LL01037WA30C -8 -244 -1 0.5 t 1.2 1.1 ± 2.7 2.5 ± 7.8 LL01038WA31C -8 -276 0 0.5 ± 1.2 0.4 ± 2.2 -2.8 ± 7.4 LL01039WA32C - -8 -216 - 0- -0.1 ±-0.1 -0.8 ± 1.6-- -3.0"-± 7.9 LL01040WA33C -8 -191 -1 -0.1 ± 0.1 0.6± 2.6 0.8 ± 7.8 LLO1D41WA34C 17 -203- 0 0.5 1.2- 0.4 ± 2.2 5.4 ± 8.7 LL01042WA35C 12 -228 0 -0.1 ± 0.1 2.8 + 2.9 -1.1 ± 7.8 LL01043WA36C -8 -167 0 -0.1 ± 0.1 -0.3 ± 2.2 -1.5 + 7.6 LL01044WA37C . 17 -187 1 -0.1 ± 0.1 0.0 ± 2.0 -0.1 ± 7.5 LL01045.WA38C -8 -127 0 -0.1 ± 0.1 0.1 ± 2.0 1.2 ±..7.7 LL01046WA39C -3 -232 -1 -0.1 ± 0.1 -2.1 ± 1.4 -2.4 ± 7.5 LL01047.WA40C -13 -248 -1 -0.1 0 0.1 0.0 ± 2.0 0.7 ± 7.5 LL01048WA41C 17 -195 0 -0.1 ± 0.1 0.5 t 2.2 -0.6 ± 7.5 LL01049WA42C . -8 -280 0 -0.1 ± 0.1 -2.1 + 1.4 4.8 ± 8.2 LL01050WA43C 2 -220 0 -0.1 + 0.1 0.0 ± 2.0 3.5 ± 8.3 LLO1051

'C-11-21

Page 80: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-out-andTermination Surv, Camp r ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/o00cmn2 dpm/100cmAn2 uR/hr dpm/100cmA2 +1-2 sigma Number

(Bkgd =>) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9(MDA >) 52 284 2.44 2.39 49.02 "

WA44C -3 -276 0 -0.1 ± 0.1 -0.8 ± 1.6 -3.6 ± 7.2 LL01052

WA45C -8 -183 -1 -0.1 ± 0.1 -0.7 ± 2.1 3.1 ± 7.4 LL01053

WA46C 2 -361 -1 -0.1 ± 0.1 0.9 ± 2.4 2.4 ± 7.7 LL01054WA47C -3 -288 -1 -0.1 ± 0.1 -1.2 ± 1.3 2.0 ± 7.8 LL01055WA48C 12 -316 -1 -0.1 ± 0.1 -0.7 ± 2.1 -0.1 ± 7.5 LL01056

WA49C -3 -256 0 0.5 ± 1.2 0.4 ± 2.2 3.9 ± 8.1 LL01057WVA50C 7 -183 0 -0.1 ± 0.1 -0.4 ± 1.8 2.5 ± 8.0 L101058

QA NIA. N/A N/A -0.1 ± 0.1 -1.2 ± 1.8 1.8 ± 7.0 LL01059

WB1A 12 -220 0 0.5 ± 1.2 -0.9 ± 1.6 -4.0 ± 7.1 LL01060

WVB2A -8 -284 0 -0.1 ± 0.1 1.0 ± 2.3 3.1 ± 8.2 LL01061WB3A 2 -175 0 -0.1 ± 0.1 -0.3 * 2.2 -4.0 ± 7.1 LL01062

w 4A -3 -199 0 -0.1 ± 0.1 -0.9 ± 1.6 -0.2 ± 8.5 LL01063

WB5A 2 -71 -1 -0.1 ± 0.1 1.4 ± 2.5 0.4 ± 8.9 LL01064

WB6A -3 -175 0 0.5 ± 1.2 -0.7 ± 2.1 -11.2 ± 10.7 LL01065

VVB7A -3 -344 0 -0.1 ± 0.1 -0.5 ± 1.8 -2.5 ± 9.9 LL01066

WB8A -3 -260 0 -0.1 ± 0.1 -0.4 ± 1.8 -6.3 ± 8.2 LL01067

WB9A -13 -232 -1 -0.1 ± 0.1 -2.1 ± 1.4 4.3 ± 10.1 LL01068VB10A -3 -232. -1 0.5 ± 1.2 0.0 ± 2.0 -1.6 ± 8.3 LL01069

WB11A.. -8 -232 -1 -0.1 ± 0.1 1.0 * 2.3 -6.8 ± 8.9 LL01070

WB12A- -13 -292 0 0.5 ± 1.2 0.2 t 2.4 A11.1 ± 9.2 LL01071WB13A.. -8 -228 0 1.1 ± 1.7 -0.5 t 1.8 -14.6 ± 12.2 LL01072

WB14A., 2 -107 0 -0.1 ± 0.1 0.5 ± 2.2 -0.6 ± 8.0 LL01073

WB15A 2 -75 0 -0.1 ± 0.1 0.2 ± 2.4 -3.6 ± 8.1 LL01074

WB16A.. -13 -119 1 -0.1 ± 0.1 -1.4 * 1.3 3.1 ± 8.2 LL01075WB17A.-. -3 -14 1 -0.1 ± 0.1 -0.4 E 1.8 3.5 ± 9.5 LL01076

WB18A-. -8 -228 0 0.5 ± 1.2 -0.7 ± 2.1 . 3.1'± 8.4 LL01077

WB1B 2 -175 0 -0.1 ± 0.1 0.9 : 2.4 -2.9 ± 9.3 L101078

WB2B -3 -42 0 0.5 ± 1.2 -0.4 ± 1.8 0.8 ± 8.6 LL01079

WB3B -13 -228 0 0.5 ± 1.2 1.5 ± 2.9 1.2 ± 7.7 LL0108DWB4B 7 -107 -1 -0.1 ± 0.1 1.3 k 2.6 -0.6 ± 7.7 LL01081

WB5B 2 -103 -1 0.5 * 1.2 0.5 k 2.2 2.6"± 8.2 LL01082

WB6B -13 -191 -1 0.5 .1.2 4.3 :t 3.6 -3.0 ± 7.9 LL01083

WB7B 2 -220 -1 -0.1 ± 0.1 1.8 ± 2.7 -4.7 ± 10.7 LL01084WB8B -8 -308 -1 -0.1 ± 0.1 0.5 ± 2.2 -2.0 ± 10.3 LL01 085

WB9B 2 -300 -1 0.5 ± 1.2 -0.3 ± 2.2 -2.0 ± 10.3 LL01086

WB10B -3 -256 -1 -0.1 ± 0.1 0.4 ± 2.2 -6.6 ± 11.7 LL01087

WB11B -8 -199 0 -0.1 ± 0.1 0.1 ± 2.0 -3.0 ± 9.6 LL01088.

WB12B -8 -187 -1 0.5 + 1.2 2.0 ± 3.0 -6.3 ± 16.7 LL01089

WB13B -8 -260 -1 0.5 ± 1.2 0.0 ± 2.0 -7.2 ± 14.3 LL01090WB14B -3 -46 0 -0.1 ± 0.1 -1.7 ± 1.0 -19.3 ± 16.0 LL01091

WB15B -8 -135 1 -0.1 ± 0.1 -1.2 ± 1.8 1.4 ± 9.3 LL01092WB16B -13 -99 1 0.5 ± 1.2 -0.5 ± 1.8 0.3 ± 7.8 LL01093

WB17B -8 -26 0 -0.1 ± 0.1 0.1 ± 2.0 0.3 ± 7.8 LL01094

WB18B -3 -119 0 -0.1 ± 0.1 -1.2 ± 1.8 -2.0 ± 7.9 LL01095

WB1C -3 -211 0 -0.1 ± 0.1 0.4 ± 2.2 -0.2 ± 9.4 LL01096

WB2C 12 -123 0 0.5 ± 1.2 -0.4 ± 1.8 3.1 ± 8.2 LL01097

WB3C 7 -155 0 -0.1 ± 0.1 2.0 ± 3.0 3.4 ± 8.1 LL01098

WB4C 2 -103 0 -0.1 ± 0.1 1.3 ± 2.6 4.8 ± 8.2 LL01099

WB5C 7 -54 0 0.5 ± 1.2 0.1 ± 2.0 7.1 ± 8.7 LL01100WB6C -8 -296 0 0.5 ± 1.2 -1.2 ± 1.8 5.8 ± 8.5 LL01101

C-11-22

Page 81: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2•MH-4939-R-97, Facility Close-o-'•andTermination Surv, Caml ilmer, NJ, 1 Jul - 20 Dec 97

_ _Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dplO00=cmA2 dprn/100cmA2 uR/hr dpmnlOOcmA2 +1-2 sigma Number

(Bkgd=>) 5 0.0 to 0.34 0.89 to 1.41 7.86 " to 7.9(MDA =>) 52 284 2.44 2.39 49.02 *WB7C 7 -216 0 -0.1 ± 0.1 0.4 t 2.2 -0.2 * 9.4 LL01102WB8C -8 -248 -1 -0.1 ± 0.1 0.5 * 2.2 -13.1 ± 8.7 LL01103WB9C -8 -284 -1 -0.1 ± 0.1 -0.3 ± 2.2 -0.8 ± 10.1 LL01104WB10C 2 -211 0 0.5 ± 1.2 2.3 ± 2.9 -4.8 ± 8.4 LL01105WB11C 12 -232 0 0.5 ± 1.2 0.1 ± 2.0 -2.1 ± 8.1 LL01106WB12C -3 -199 -1 0.5 ± 1.2 0.6 ± 2.6 -9.6 ± 9.8 LL01107WB13C -8 -224 -1 -0.1 ± 0.1 -0.9 ± 1.6 -7.6 ± 12.0 LL01108WB14C -3 -304 -1 -0.1 ± 0.1 -1.2 ± 1.3 -9.8 + 12.8 LL01109WB15C -3 -348 0 -0.1 ± 0.1 -0.3 ± 2.2 1.9 ± 8.9 LL01110WB16C .3 -272 0 -0.1 ± 0.1 -1.8 ± 1.0 -7.7 + 7.0 LL01111WB17C -3 -244 0 -0.1 ± 0.1 -0.8 ± 1.6 -0.6 ± 7.7 LL01112WB18C -13 -272 0 1.7 t 2.1 0.2 ± 2.4 6.8 ± 8.8 LL01113QA NIA N/A N/A -0.1 t 0.1 -0.5 ± 1.8 1.5 ± 7.1 LL01114WC1A 7 -316 0 -0.1 ± 0.1 0.5 ± 2.2 -1.3 ± 9.5 LL01115WC2A -3 -264 0 -0.1 ± 0.1 -0.7 ± 2.1 -2.1 ± 8.1 LL01116WC3A -13 -216 0 -0.1 ± 0.1 0.4 ± 2.2 1.2 ± 7.9 LL01117WC4A -8 -199 -1 -0.1 ± 0.1 -1.7 ± 1.0 -3.3 * 7.5 LL01118WC5A -13 .- 272 -1 -0.1 ± 0.1 -2.1 ± 1.4 -3.1 ± 8.1 LL01119WC6A -3 -163 0 0.5 ± 1.2 -1.4 ± 1.3 -2.9 ± 7.6 LL01120WC7A -13 -159 0 0.5 ± 1.2 1.0 ± 2.3 -1.2 ± 9.3 LL01121WC8A -8 -252 0 -0.1 ± 0.1 -1.6 ± 1.6 -1.9 ± 7.5 LL01122!WC9A -8 -361 0 -0.1 ± 0.1 0.0 ± 2.0 3.8 ± 8.0 LL01123WC10A -8 -211 0 -0.1 ± 0.1 2.3 ± 2.8 3.5 ± 8.3 LL01124WC11A 7 -183 0 -0.1 ± 0.1 -2.1 ± 1.4 5.2 * 8.3 LL01125WC12A -8 -240 0 0.5 ± 1.2 0.9 ± 2.4 -7.0 ± 7.1 LL01126WC13A -8 -236 0 -0.1 ± 0.1 -1.2 ± 1.3 0.8 ± 7.8 LL01127WC14A 2 -167 0 -0.1 ± 0.1 -0.7 ± 2.1 -3.3 ± 7.5 LL01128WC15A -3 -272 0 0.5 ± 1.2 2.7 ± 3.0 -0.6 ± 8.0 LL01129WC16A -8 -232 0 -0.1 ± 0.1 -0.4 ± 1.8 6.1 ± 8.4 LL01130WC17A -13 .248 0 -0.1 ± 0.1 0.6 ± 2.6 -1.5 ± 7.9 LL01131WC18A 12 -95 0 1.1 ± 1.7 -1.4 ± 1.3 -2.4 t 7.6 LL01132WC19A 2 -288 0 -0.1 ± 0.1 -0.4 ± 1.8 0.8 * 7.8 LL01133WC20A -8 -183 -1 -0.1 ± 0.1 -0.7 ± 2.1 3.4 * 7.9 LL01134WC21A -13 -199 -1 -0.1 ± 0.1 0.9 ± 2.4 3.0 ± 8.1 LL01135WC22A 2 -187 0 -0.1 ± 0.1 .0.5 * 2.2 1.6 ± 7.6 LL01136WC23A 2 -131 0 -0.1 t 0.1 -0.3 ± 2.2 1.7 ± 8.1 LL01137WC24A 7 -107 0 -0.1 ± 0.1 0.4 ± 2.2 -8.6 ± 8.1 LL01138WC25A -13 -272 0 -0.1 ± 0.1 -0.8 ± 1.6 -5.5 ± 7.8 LL01139WC26A -8 -123 0 0.5 ± 1.2 -0.7 ± 2.1 1.2 ± 8.0 LL01140WC27A -3 -240 0 0.5 * 1.2 0.0 ± 2.0 3.5 ± 8.3 LL01141WC28A -3 -292 0 0.5 ± 1.2 -0.8 ± 1.6 1.2 ± 8.0 LL01142WC29A. -3 -320 0 -0.1 ± 0.1 -0.7 ± 2.1 -4.1 ± 7.3 LL01143WC30A -8 -224 0 0.5 ± 1.2 0.4 ± 2.2 0.8 * 7.8 LL01144WC31A -3 -312 0 0.5 ± 1.2 -0.4. ± 1.8 -0.1 ± 7.9 LL01145WC32A 7 -199 0 -0.1 ± 0.1 -0.3 ± 2.2 -1.5 ± 7.7 LL01146

WC33A -8 -95 -1 -0.1 ± 0.1 0.9 ± 2.4 -1.5 ± 7.9 LL01147WC34A 2 -328 0 -0.1 ± 0.1 0.5 ± 2.2 -2.5 ± 8.0 LL01148WC35A -8 -272 0 -0.1 ± 0.1 -1.6 ± 1.6 3.4 ± 8.1 LL01149WC36A -8 -187 0 -0.1 ± 0.1 -1.8 ± 1.0 0.8 t 7.8 LL01150WC37A -13 -256 0 1.1 ± 1.7 1.0 ± 2.3 -1.5 t 7.7 LL01151

C-1 1-23

Page 82: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-ou•--andTermination Surv, Camp )•lmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9

Location Monitoring .... Wipe TestCode Alpha " Beta Gamma Alpha Beta LS Wipe

(Units >) dpm/100cmA2 dpmn/100cm^2 uRlhr dpm/100cm^2 +1- 2 sigma Number

(Bkgd >) 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9

(MDA >) 52 284 - 2.44 2.39 " 49.02

WC38A -3 -304 0 -0.1 ± 0.1 0.6 * 2.4 -0.6 ± 7.8 LL01152

WC39A -3 -296 0 -0.1 ± 0.1 -0.1 ± 2.0 -2.7 ± 8.4 LL01153

WC40A 7 -216 0 -0.1 ± 0.1 4.2 ± 3.3 -3.3 ± 7.5 LL01154

WC41A -13 -361 0 -0.1 ± 0.1 1.1 ± 2.6 -2.0 ± 7.9 LL01155

WC42A -3 -175 0 -0.1 ± 0.1 -0.1 ± 2.0 -0.6 ± 7.7 LL01156

WC43A 12 -236 0 -0.1 ± 0.1 -0.2 ± 1.8 -4.1 ± 9.2 LL01157

WC44A -8 -256 -1 -0.1 ± 0.1 -2.1 ± 1.0 -1.5 ± 7.7 LL01158

WC45A -3 -232 0 0.5 ± 1.2 -1.0 ± 1.6 2.1 ± 8.1 LL01159

WC46A -3 -175 0 0.5 ± 1.2 0.2 ± 2.0 -1.0 ± 7.6 LL01160

WC47A -8 . -183. 0 -0.1 ± 0.1 0.6 ± 2.4 1.7 ± 8.1 LL01161

WC48A -8 -216 . 0 -0.1 ± 0.1 0.3 ± 2.2 -3.8 ± 7.5 LL01162

WC49A -3 -244... 0 0.5 ± 1.2 1.6 ± 2.5 2.6 ± 8.2 LL01163

WC50A 2 -244 0 -0.1 ± 0.1 -0.3 ± 2.0 -0.1. ± 7.5 LL01164

WC1B 7 -232 .. 0 -0.1 ± 0.1 0.8 ± 2.4 -4.3 ± 7.6 LL01165

WC2B 2 -191 0 -0.1 ± 0.1 -1.1 ± 1.3 1.6 ± 7.9 LL01166

WC3B -13 -280.-. 0 -0.1 ± 0.1 0.2 ± 2.2 0.8 ± 7.8 LL01167

WC4B -8 .- 232 0 -0.1 ± 0.1 0.8 ± 2.4 5.4 ± 8.0 LL01168

WC5B 7 -248.. -1 -0.1 ± 0.1 -1.6 ± 1.0 -2.4 ± 9.4 LL01169

WC6B -3 -224 0 -0.1 ± 0.1 0.2 1 2.2 -1.1 ± 8.2 LL01170

WC7B -13 -236 . -1 -0.1 ± 0.1 2.6 1 3.0 -7.5 ± 7.6 LL01171

WC8B 7 -292 0 -0.1 ± 0.1 1.1 ± 2.3 1.6 * 7.7 LL01172

WC9B -3 -248 0 -0.1 ± 0.1 2.4 1 3.0 -0.6 ± 7.7 LL01173

WC10B -3 -292 0 -0.1 ± 0.1 -1.9 ± 1.0 -0.1 ± 7.9 LL01174

WC11BB -3 -220 0 -0.1 ± 0.1 2.0 ± 2.6 5.6 ± 8.3 LL01175

WC12B -8 -240 1 0.5 ± 1.2 1.5 ± 2.7 4.7 t 8.1 LL01176

WC13B1 -13 -183 0 -0.1 ±'0.1 1.3 + 2.6 1.2 ± 7.5 LL01177

WC14B1" -8 -369 0 -0.1 ± 0.1 0.2 ± 2.0 1.3 ± 8.4 LL01178

WC15B 2 -232 1 -0.1 ± 0.1 .0.2 ± 2.2 2.9 ± 7.9 LL01179

WC16B 2 -179 1 -0.1 ± 0.1 -1.5 1 1.3 1.6 ± 7.6 LL01180

WC17B -8 -324 0 -0.1 ± 0.1 -0.7 k 1.6 5.2 ± 8.3 LL01181

WC18B -13 -207 0 -0.1 ± 0.1 -0.3 ± 2.0 -6.4 ± 7.0 LL01182WC19B -3 -183 0 -0.1 ± 0.1 0.3 ± 2.2 -0.6 ± 7.5 LL01183

WC20B 2 -244 0 -0.1 ± 0.1 0.2 ± 2.0 -4.9 ± 8.6 LL01184

WC21B , -3 -167. 0 -0.1 ± 0.1 -1.6 + 1.3 -3.2 ± 7.4 LL01185

WC22B 7 -179 0 0.5 ± 1.2 2.2 ± 2.9 -4.6 ± 7.2 LL01186

WC23B 7 -236 0 -0.1 ± 0.1 -0.7 + 1.6 -3.6 ± 7.2 LL01187

WC24B -3 -187 0 -0.1 ± 0.1 0.6 ± 2.4 -1.0 ± 7.6 LL01188

WC25B 7 -232 0 -0.1 ± 0.1 1.3 ± 2.6 -1.0 ± 7.3 LL01189

WC26B -8 -187 0 -0.1 ± 0.1 0.7 + 2.2 1.6 ± 7.7 LL01190

WC27B 2 -220 0 -0.1 ± 0.1 0.2 :: 2.2 -2.0 ±. 7.7 LL01191

WC28B -8 -248 0 -0.1 ± 0.1 -0.1 ± 2.0 -4.2 ± 7.4 LL01192

WC29B -8 -220 1 -0.1 ± 0.1 -1.1 t 1.3 -2.4 ± 7.6 LL01193

WC30B 2 -280 0 0.5 ± 1.2 1.5 ± 2.7 0.9 ± 9.5 LL01194-.

WC31B -3 -224 0 -0.1 ± 0.1 -0.1 ± 2.0 -2.0 ± 7.9 LL01195

WC32B 2 -336 0 0.5 ± 1.2 1.1 ± 2.3 -3.3 ± 7.5 LL01196

WC33B -8 -179 0 0.5 ± 1.2 1.1 t 2.6 -2.4 ± 7.5 LL01197

WC34B 2 -175 0 -0.1 ± 0.1 0.3 ± 2.2 0.3 ± 7.6 LL01198

WC35B 7 -248 0 -0.1 ± 0.1 1.1 ± 2.3 -5.4 ± 6.9 LL01199

WC36B -8 -159 0 -0.1 ± 0.1 -0.7 t 1.8 -12.1 ± 9.4 LL01200

WC37B 2 -357 0 -0.1 ± 0.1 -0.6 ± 1.8 -3.7 ± 8.3 LLO12O1

C-1 1-24

Page 83: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 'Th•H-4939-R-97, Facility Close-c'¢')andTermination Surv, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 ROOM 9Location Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta; LS Wipe

(Units >) dpm/100cmA2 dpmrlOOcmA2 uR/hr dpmlO00cmA2 +1- 2 sigma Number

(Bkgd=>) 5 -0.0 to 0.34 0.89 to- 1.41 7.86 to 7.9

(MDA >) 52 284 - 2.44 2.39 * 49.02 *WC38B -13 -280 0 -0.1 * 0.1 1.6 ± 2.5 -2.2 ± 8.7 LL01202WC39B 2 -260 0 -0.1 ± 0.1 -1.2 ± 1.6 -4.3 ± 7.6 LL01203WC40B 2 -304 0 -0.1 ± 0.1 -0.2 ± 1.8 -0.6 ± 7.7 LL01204WC41B 7 -381 0 -0.1 ± 0.1 0.2 ± 2.2 -3.6 ± 8.1 LL01205WC42B -3 -284 0 -0.1 ± 0.1 -1.9 ± 1.0 -5.1 ± 7.3 LL01206WC43B -13 -183 0 -0.1 ± 0.1 1.3 ± 2.6 -3.5 ± 7.9 LL01207WC44B -8 -236 0 -0.1 ± 0.1 1.5 ± 2.7 - 0.3 ± 7.6 LL01208 -

WC45B -8 -288 0 -0.1 ± 0.1 2.2 ± 2.9 -4.0 ± 7.8 LL01209WC46B 7 -191 0 -0.1 ± 0.1 -0.1 ± 2.0 2.5 ± 7.8 LL01210WC47B -13 - -256 1 -0.1 ± 0.1 -1.1 ±1.3 -2.5 ± 8.0 LL01211..WC48B -3 -179 0 7.2 ± 4.1 7.2 ± 4.1, -1.0 ± 7.4 LL01212WC49B -8 -203 0 0.5 ± 1.2 0.3 ± 2.2 -1.5 ± 7.6 LL01213WC50B -13 -... -272 -1 -0.1 ± 0.1 2.0 ± 2.6 -3.6 ± 7.2 LL01214-WC1C 2 -300 0 -0.1 ± 0.1 -2.1 ± 1.0 -3.9 ± 7.6 LL01215WC2C 2 -252 0 -0.1 ± 0.1 0.3 ± 2.2 -3.6 ± 8.1 LL01216WC3C -13 -240 -1 -0.1 ± 0.1 0.2 ± 2.P -1.1 ± 8.2 LL01217WC4C -8 -264 0 -0.1 ± 0.1 0.6 * 2.4 -1.1 ± 8.2 LL01218WC5C 2 -244 0 0.5 ± 1.2 -1.5 ± 1.3 -0.1 ± 7.7 LL01219

WC6C -3 -171 0 -0.1 ± 0.1 -0.7 ± 1.6 -0.6 ± 7.8 LL01220WC7C 2 -171 0 -0.1 ± 0.1 -0.3 ± 2.0 -6.4 ± 7.0 LL01221WC8C 12 -75 0 -0.1 ± 0.1 -0.6 ± 1.8 -3.7 ± 7.3 LL01222WC9C -3 26 0 -0.1 ± 0.1 1.1 ± 2.3 -2.5 ± 7.8 LL01223WC10C 7 -123 0 -0.1 ± 0.1 1.1 ± 2.6 -1.1 ± 7.8 LL01224WC11C 12 -260 0 -0.1 ± 0.1 -0.1 ± 2.0 -1.9 ± 7.5 LL01225WC12C 2 -91 -1 -0.1 ± 0.1 -1.1 ± 1.3 0.3 ± 7.6 LL01226WC13C -8 -103 0 0.5 ± 1.2 -0.7 ± 1.8 -2.1 ± 8.2 LL01227WC14C -8 -211 0 -0.1 ± 0.1 0.8 ± 2.4 -3.2 ± 10.2 LL01228WC15C -8 -159 0 -0.1 ± 0.1 0.7 ± 2.2 -4.7 ± 8.2 LL01229WC16C 2 -143 0 -0.1 ± 0.1 -0.3 ± 2.0 -2.7 ± 8.4 LL01230WC17C -3 -107 0 0.5 ± 1.2 -1.9 ± 1.0 -6.3 ± 8.2 LL01231WC18C -8 -159 0 0.5 ± 1.2 -1.1 ± 1.3 -3.1 ± 8.1 LL01232WC19C -8 -211 0 -0.1 ± 0.1 1.1 ± 2.6 -10.8 ± 6.8 LL01233WC20C -13 -163 0 -0.1 ± 0.1 -0.6 ± 1.8 -1.1 ± 8.2 LL01234WC21C 17 -216 0 -0.1 ± 0.1 -1.1 ± 1.3 -6.3 ± 8.2 LL01235WC22C 12 -187 0 -0.1 ± 0.1 -1.2 ± 1.6 0.3 ± 7.9 LL01236WC23C -3 -252 1 -0.1 ± 0.1 0.8 ± 2.4 0.3 ± 7.9 LL01237WC24C -3 -123 1 0.5 ± 1.2 1.1 ± 2.3 -0.1 ± 7.5 LL01238WC25C -8 -228 1 -0.1 ± 0.1 0.2 ± 2.2 -0.1 ± 7.9 LL01239WC26C -3 159 0 -0.1 ± 0.1 1.3 ± 2.6 -1.5 ± 7.7 LL01240WC27C -3 75 0 -0.1 ± 0.1 -0.7 ± 1.6 4.1 ± 9.6 LL01241WC28C 2 -264 0 -0.1 ± 0.1 -1.2 ± 1.6 3.1 ± 8.4 LL01242WC29C 12 -151 1 -0.1 ± 0.1 0.3 ± 2.2 -1.7 ± 8.5 LL01243WC30C 2 -211 0 0.5 ± 1.2 0.7 ± 2.2 -2.1 + 8.1 LL01244WC31C -8 -236 0 -0.1 ± 0.1 -0.7 ± 1.8 -7.2 ± 7.9 LL01245WC32C 23 -220 0 -0.1 ± 0.1 0.8 ± 2.4 -0.2 ± 8.9 LL01246WC33C -8 -123 0 0.5 ± 1.2 2.0 ± 2.6 -5.5 ± 7.8 LL01247WC34C -13 -199 0 -0.1 ± 0.1 -0.7 ± 1.8 -0.1 ± 7.7 LL01248WC35C -8 -268 -1 -0.1 ± 0.1 1.3 ± 2.6 -3.8 ± 7.5 LL01249WC36C 2 -292 -1 -0.1 ± 0.1 0.7 ± 2.2 -1.0 ± 7.6 LL01250WC37C 2 -216 0 -0.1 ± 0.1 -1.6 ± 1.3 0.3 ± 7.8 LL01251

C-11-25

Page 84: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

'Indust Radn Surv No. 27-MMH-4939-R-97, Facility Close-oitt andTermination Surv, Can" >ilmer, NJ, 1 Jul - 20 Dec 97

-... ..... Camp Kilmer, BUILDING 1072 ROOM 9

Location . .... ..... M onitoring ..-...... .... .... ..... ......... W ipe Test

Code Alpha Beta Gamma Alpha -... - Beta LS Wipe

(Units >) dpm/1r00Ac^2 dpmrl00cmA2 uR/hr dpm/100cmA2 +1- 2 sigma Number

(Bkgd =>) 0 . 5 0.0 to 0.34 0.89 to 1.41 7.86 to 7.9.

(MDA>) 52 , .284 . .2.44 " - 2.39 " 49.02 _____

WC38C ... .. 7 .. -.- 30 0- -0.1- *- 0.1 -0.6 t 1.8 ...- 2.4-+ 7.6 LL01252-

WC39C -8 -187 -- 0 -0.1 ± 0.1 ±1.1± 2.3, - -2.0 ± 7.7 LL01253

WC40C 2. -240 .0 -0.1 ± 0.1 -0.3 ± 2.0-- 3.4 ± 8.1 LL01254

WC41C -3 -344 0 -0.1 + 0.1 -0.6 ± 1.8 -3.5 ± 7.9 LL01255

WC42C -8 -183 0 -0.1 ± 0.1 0.2 ± 2.0 -3.2 ± 7.4 LL01256

WC43C_ 12 -304- 0 -0.1 + 0.1 - 0.2 ± 2.2 -4.0 "t 7.8 LL01257WC44C -3 .-135 0 --0.1 ± O.1 -1.0± 1.6-.:, -5.9 ± 7.0 LL01258

WC45C -3 -42 0 -0.1 -:0.1. -0.7 1.6' 1.3 ± 8.6 LL01259

WC46C 2 -99 0 .0.5 t 1.2- 2.4 + 3.0.- 7.1 ± 19.1 LL01260

WC47C - 7 -107 0 . 0.5 1.2 -1.3 ±-2.6:- -8.9 ± 9.8 LL01261-

WC48C -3. -167. 0 -0.1 * 0.1 1.1 ± 2.3. -2.6 ± 8.2 LL01262

WC49C 7 -236. 0 -0.1 0.1 -2.1 ± 1.0 7 -0.1 ± 8.3 LL01263

WC50C . -8 -143 0 -0.1 * 0.1- -0.1 ± 2.0 -0.6 ± 7.8 LL01264

QA N/A N/A . N/A -0.1 ± 0.1 ---0.7 ± 1.6 970.6 ± 43.5 LL01265

WD1A .- 3 -187 0 0.5 + 1.2- --1.6 -± 1.3 -10.2 ± 8.5 LL01266

WD2A -13 -224 0 -0.1- ± 0.1. -0.1 "-± 2.0 -6.1 ± 7.2 LL01267

WD3A -13 -191. 0 -0.1 + 0.1 0.7 ± 2.2 -4.8 ± 7.5 LL01268

WD4A -13 -220 . 1 -0.1 ± 0.1 0.2 ± 2.2 8.2 ± 9.3 LL01269

WD5A -8 -203 1 -0.1 ± 0.1 -0.6 ± 1.8 -3.4 ± 7.7 LL01270

WD6A 17 . -179 0 -0.1 ± 0.1 -1.6- ± 1.0-- -5.0 ± 7.9 LL01271'

WD7A -13 -115 0 -0.1 ± 0.1 -0.3 ± 2.0 -3.9 ,t 7.6 LL01272

WD8A -13 -187 0 - -0.1 ± 0.1 -1.0 ± 1.6 -5.7 ± 7.4 LL01273

WD9A -3 -191 0 0.5 ± 1.2 -0.2 ± 1.8 -6.7 ± 7.3 LL01274

WD10A -8 -175 0 -0.1 ± 0.1 -0.3 ± 2.0 -2.2 ± 8.4 LL01275

WD11A 7 -216 0 -0.1 ± 0.1 1.3 ± 2.6 -2.0 ± 7.9 LL01276

WD12A -8 -203 0 -0.1 k 0.1 -0.2 ± 1.8 -2.9 ± 7.8 LL01277

WD13A 2 -232 . 0 0.5 ± 1.2 0.6 ± 2.4 -21.1 ± "12.6 LL01278

WD14A -8 -228 0 -0.1 ± 0.1 0.8 ± 2.4 -5.9 ± 9.3 LL01279

WD15A -13 -163 0 -0.1 ± 0.1 1.1 ± 2.3 -11.6 ± 8.6 LL01280

WD16A -3 -216 0 1.1 ± 1.7 2.4 ± 3.0 -12.1 ± 9.4 LL01281

WD17A -8 -252 1 0.5 1 1.2 -0.6 ± 1.8 -9.4 ± 8.3 LL01282WD18A -13 -256 0 -0.1 :t 0.1 0.2 t 2.0 -1.7 ± 8.9 LL01283

WDIB -8 -264 1 -0.1 ± 0.1 0.6 ± 2.4 -3.4 ± 7.7 LL01284

WD2B 7 66 0 0.5 ± 1.2 -1.5 ± 1.3 -11.4 ± 9.5 LL01285

WD3B -8 -143 1 -0.1 ± 0.1 -0.2 ± 1.8 -14.5 ± 10.7 LL01286

WD4B -8 -139 1 -0.1 ± 0.1 -1.2 ± 1.6 -11.7 ± 9.2 LL01287

WD5B -8 -151 0 -0.1 ± 0.1 1.3 ± 2.6 -21.1 ± 12.6 LL01288

WD6B -13 -203 0 -0.1 ± 0.1 -0.7 ± 1.6 -15.6 ± 11.5 LL01289

WD7B -13 -135 0 -0.1 ± 0.1 1.1 : 2.6 -11.1 ± 9.2 LL01290

WD8B -3 -228 0 -0.1 ± 0.1 -0.1 ± 2.0 -8.5 ± 11.0. LL01291

WD9B 2 -143 1 0.5 ± 1.2 -0.2 ± 1.8 -1.2 ± 9.3 LL01292

WD19B -3 -236 • 0 -0.1 ± 0.1 0.6 ± 12.4 -11.2 ± 9.9 LL01293

WD11B 7 -167 0 0.5 ± 1.2 1.7 ± 2.7 -8.7 ± 7.7 LL01294

WD12B -13 -220 0 0.5 t 1.2 -0.2 ± 1.8 -13.1 ± 9.7 LL01295

WD13B -3 -224 0 0.5 ± 1.2 1.5 ± 2.7 -10.6 + 7.0 LL01296

WD14B -3 -272 1 0.5 ± 1.2 1.3 ± 2.6 -3.2 ± 8.3 LL01297

WD15B -3 -199 1 0.5 ± 1.2 2.9 ± 2.9 -8.2 ± 10.6 LL01298

WD16B -8 -163 0 -0.1 ± 0.1 -0.3 ± 2.0 -12.7 ± 9.4 LL01299

WD17B 17 -308 0 -0.1 ± 0.1 -0.1 ± 2.0 -6.1 + 9.5 LL01300

WD18B -3 -203 1 -0.1 ± 0.1 0.7 t 2.2 -3.1 + 12.1 LL01301

C-11-26

Page 85: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 21'-MH-4939-R-97, Facility Close-o?-->andTermination Surv, Cam- lIlmer, NJ, I Jul - 20 Dec 97

........ Camp Kilmer, BUILDING 1072 ROOM 9 . -.........

Location Monitoring " . . .... Wipe TestCode Alpha Beta Gamma - Alpha Beta.: - LS Wipe:

(Units =>) dpm/l00cm^2 dpmrlOOcm^2 uRlhr. . dpm/100cm^ 2 +1-2 sigma Number

(Bkgd 5>) 52. .. 5 -0.0 . to - 0.34- 0.89. to 1.41 7.86 'to'- 7.9(MDA >) 52 . 284 . ....-..... 2.44-.- --- 2.39 -- --.. 49.02 .. . '

WDlC 12 -71T .1.. 0.5 ± - 1.2 1.1--± 2.6-;- -7.0L ±" 8.3 LL01302WD2C -3 -260 0 -0.1 0.1 0.3"-± 2.2:- --9.4 ± 8.3 LL01303WD3C. . -3- . -62 -. .. 0 -0.1 ± 0.1 .. 1.1 ± 2.3 .- -12.2 ± 10.2 LL01304WD4C' -8 -147-, 0 2.3. ±. 2.4 - 3.4 ±-3.2 , -14.2 ± 9.9 LL01305.

WD5C -8 .-83.- _1 1.1 ±1-1.7 0.8-± 2.4 .- 7.0 ± 9.1 LL01306"WD6C 12 -191 - 0 . -0.1 ± 0.1 1.1 ±-.2.3-. -14.6 *19.1 LL01307

WD7C -8 . -115 0.- -0.1 ± .0.1 3.8 ±- 3.4 ' -11.0 ± 12.1 LL01308

WD8C 7 -66.. . . 0- 0.5 ± 1.2 1.3 ±.2.6 : -11.6- ± 11.1 LL01309-

WD9C - -8 -159,_ 0- -0.1± -- 0.1 . 1.6 ± 2.5 A13.3 ± 10.4 LL01310,

WD10C 12 - -183.. 0 -0.1- ± 0.1 -1.6 ± 1.3 -6.3 "± 8.9 LL01311WD11C -8. -308.. 1 -0.1 ±--0.1 -0.6 ± 1.8. -7.2 ± 7.9 LL01312

WD12C -3 __50,_ 0 0.5 ± 1.2 1.1 ±--2.3 -2.7 ± 8.6 LL01313WD13C 7 -183... 0 .-- 0.5 ± 1.2 -0.7 ±- 1.8 -7 5.6 ± 8.8 LL01314

WD14C -8 -199 _ _.. 0 .0.5 * 1.2 1.7.± 2.7 -16.6- ± 9.6- LL01315.

WD15C . 7 -187.. 0 -0.1 ± 0.1 2.0 ± 2.6 -5.2 ± 10.3- LL01316,WD16C -8 -284 . 0 0.5 ± -1.2 -2.1 ± 1.0, -7.4 ± 13.1 LL01317,.WD17C -13 -228:- 1 -0.1. ± 0.1 --- 0.6 - 1.8 - -7.9 ± 12.5 LL01318 -

WD18C -3 -304 .1 . -0.1 ± .-0.1 1.1 - ± 2.3 -7.1 ±10.1 LL01319QA N/A N/A N/A -0.1 ±.. 0.1 -- 0.2 ±- 2.2 003.4 ± 44.8 LL01320

DRAIN FJ6 12 -38 .0 0.5 ± 1.2 4.9 ± 3.6 -- 7.2 ± 7.9 LL01321DRAIN FJ17 17 -42 0 -0.1 * 0.1 0.7 ±- 2.2 -9.9 ± 10.1 LL01322DRAIN FE46 2 -95. -1 1.1 ± 1.7 0.2 ± 2.2 -9.9 ± 9.4 LL01323

Indicates the highest MDA for this survey unt. "The Alpha MDA ranged from 1.78 to 2.44 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.84 to 2.39 dpm

Indicates the highest MDA for this survey unit. The H-3 MDA ranged from 12.49 to 49.02 dpm

C-1 1-27

Page 86: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

q

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 10725M m Cx&m~

A1

24

47

70

93

116

139

162

185

208

231

254

FA 12 212 12 23

35 4

' 5 69

81 92ID Il

104 I115

127 138

150 161

-- 173 104

196 * =207

219 230

I1 242 - 253

FA1I 25S3 f- * 276

1

BUILDING 1072, CAMP KhLMER. NEW JERSEY DATE. 20OCT 97

DRAWN; MSM

U.S. ARMY CENTER FOR HEALTH PROMOTION A1PROVED: HEAND PREVENTIVE MEDICINE S Ns

UNITED STATES ARMY MEDICAL DEPARTMENTPLATE N/A

C-12

Page 87: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. •H-4939-R-97, Facility Close-€c-)andTermination Surv, Camf Ailmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 DOWNSTAIRS FLOOR RANDOMSLocation Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpmnl00cmA2 dpmlOOcmA2 uRlhr dpmlO00cmA2 +1-2 sigma Number

(Bkgd 6>) 0.1 to 0.33 0.93 to 1.48 7.86 to 7.9(MDA>) 52 227 - 2 2.14 " 42.48RFA1 2 156 0 -0.2 ± 0.2 0.6 ± 2.2 -6.0 ± 15.9 LL02609RFA2 7 253 0 0.2 ± 1.2 -0.6 ± 2.2 -8.7 ± 8.9 LL02610RFA3 -8 224 0 -0.3 ± 0.2 0.8 ± 2.4 -14.2 ± 9.9 LL02611RFA5 -3 147 0 0.4 ± 1.2 -0.7 ± 1.6 -25.7 ± 20.1 LL02612RFA10 12 101 0 0.2 ± 1.2 -0.2 ± 2.4 -13.5 ± 10.0 LL02613RFA11 -8 118 0 0.3 + 1.2 3.5 ± 3.2 -16.6 ± 19.8 LL02614RFA12 7 211 0 -0.2 ± 0.2 1.5 ± 2.5 -5.6 ± 8.8 LL02615RFB12 -3 101 0 0.2 ± 1.2 1.2 ± 2.9 -10.2 ± 8.5 LL02616RFB10 2 156 0 -0.3 ± 0.2 -0.6 ± 1.8 -13.3 ± 18.9 LL02617RFB9 -13 224 0 0.4 ± 1.2 0.6 ± 2.2 -10.8 ± 15.3 LL02618RFB6 7 224 0 0.2 ± 1.2 -0.2 ± 2.4 -9.8 ± 10.9 LL02619RFB5 -13 122 0 0.3 ± 1.2 0.8 ± 2.4 -16.8 ± 13.1 LL02620RFB3 -3 126 0 -0.2 * 0.2 0.2 ± 2.0 -13.1 ± 9.7 LL02621RFB2 -8 152 0 0.2 ± 1.2 3.4 ± 3.5 -10.3 ± 16.2 LL02622RFB1 -3 236 0 0.3 ± 1.2 -1.0 ± 1.6 -19.4 ± 12.8 LL02623RFC1 -13 160 0 -0.2 ± 0.2 3.7 ± 3.2 -8.3 ± 9.9 LL02624RFC4 -8 190 0 0.8 ± 1.7 1.2 ± 2.9 -12.9 * 10.1 LL02625RFC5 -8 139" 0 -0.3 ± 0.2 1.7 ± 2.7 -15.0 ± 11.1 LL02626RFC6 -13 126 0 0.4 ± 1.2 -0.7 ± 1.6 -4.9 ± 9.7 LL02627RFC7 -13 202 0 -0.4 ± 0.2 -0.6 ± 2.2 -12.1 ± 11.5 LL02628RFC8 -3 190 0 0.9 ± 1.7 -1.0 ± 1.6 -5.2 ± 11.8 LL02629RFC9 -8 147 0 -0.2 ± 0.2. 0.6 ± 2.2 -9.0 ± 9.2 LL02630RFC11 -3 160 0 -0.4 ± 0.2 -1.5 ± 1.9 -11.1 ± 9.2 LL02631RFC12 2 156 0 0.3 ± 1.2 -1.0 ± 1.6 -6.3 ± 8.9 LL02632RFD12 -13 173 0 0.4 ±. 1.2 0.6 ± 2.2 -12.1 ± 11.5 LL02633RFD11 -13 84 0 0.2 ± 1.2 3.0 ± 3.4 -12.8 ± 11.4 LL02634RFD9 2 135 0 0.9 ± 1.7 -0.1 ± 2.0 -10.2 ± 9.7 LL02635RFD6 2 152 0 -0.2 ± 0.2 0.2 ± 2.0 -4.6 ± 9.1 LL02636RFD5 -13 139 0 0.2 ± 1.2 -1.1 ± 2.1 -16.1 ± 10.1 LL02637RFD4 -8 109 0 0.9 ± 1.7 -1.0 ± 1.6 -0.2 ± 10.2 LL02638RFD3 -3 152 0 -0.2 ± 0.2 0.6 ± 2.2 -1.9 ± 10.0 LL02639RFD2 -13 262 0 0.2 * 1.2 -0.6 ± 2.2 -2.4 ± 12.2 LL02640RFD1 -8 76 0 -0.3 ± 0.2 1.3 ± 2.6 -9.3 ± 8.8 LL02641RFE3 -8 50 0 -0.2 ± 0.2 -1.2 ± 1.3 -12.9 ± 9.0 LL02642RFE4 -8 287 0 -0.4 ± 0.2 -1.5 * 1.9 - -5.6 ± 9.9 LL02643RFE5 -8 160 0 0.3 ± 1.2 3.1 ± 3.1 -8.8 ± 8.4 LL02644RFE6 -3 177 0 0.4 ± 1.2 1.0 * 2.3 -7.9 ± 8.0 LL02645RFE7 -8 147 0 -0.4 ± "0.2 -2.4 ± 1.4 -6.3 ± 8.2 LL02646RFE1 1 2 262 0 -0.3 ± 0.2 0.8 ± 2.4 -6.9 ± 9.7 LL02647RFF12 -3 126 0 -0.2 ± 0.2 1.0 ± 2.3 -5.7 ± 9.0 LL02648RFF11 -13 245 0 -0.4 ± 0.2 -2.0 ± 1.6 -14.9 ± 9.8 LL02649RFF10 -3 131 0 -0.3 ± 0.2 2.2 ± 2.9 -5.3 ± 9.3 LL02650RFF9 -13 177 0 -0.2 ± 0.2 1.5 ± 2.5 -12.9 ± 9.0 LL02651RFF8 -3 186 0 0.8 ± 1.7 2.1 ± 3.1 -8.8 ± 11.4 LL02652RFF6 2 118 0 0.3 ± 1.2 3.1 ± 3.1 -7.5 ± 7.6 LL02653RFF4 2 202 0 -0.2 ± 0.2 -0.7 ± 1.6 -6.8 ± 8.1 LL02654RFF3 -13 194 0 -0.4 ± 0.2 -0.2 ± 2.4 -7.5 ± 9.7 LL02655RFG1 7 93 0 -0.3 ± 0.2 0.3 ± 2.2 -4.9 ± 9.7 LL02656RFG2 2 181 0 0.4 ± 1.2 -0.3 ± 1.8 -3.3 ± 8.8 LL02657RFG3 2 126 0 -0.4 ± 0.2 -2.0 ± 1.6 -3.1 ± 9.9 LL02658

C-12-1

Page 88: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27yMH-4939-R-97, Facility Close-ouw andTermination Surv, Caml _imer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 DOWNSTAIRS FLOOR RANDOMSLocation Monitoring - Wipe Test,

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dpm/1OOcmA2 dpmr/1OOcmA2 uRlhr dpm/100cmA2 +1-2 sigma Number

(Bkgd >) ._ 6 0.1 to 0.33 0.93 to 1.48 7.86 to 7.9

(MDA=>) 52 227 - 2 * 2.14 42.48 °

RFG4 -13 126 0 -0.3 + 0.2 2.2 ± 2.9 -10.2 ± 7.9 LL02659

RFG7 -13 169 0 -0.2 ± 0.2 2.4 ± 2.8 -9.6 ± 8.5 LL02660

RFG11 -3 126 0 -0.4 ± 0.2 -0.2 ± 2.4 -6.3 ± 8.9 LL02661

RFH12 -3 236 0 0.3 ± 1.2 1.7 ± 2.7 -4.1 ± 8.0 LL02662

RFH11 -13 152 0 -0.2 ± 0.2 0.6 ± 2.2 -5.5 ± 7.8 LL02663

RFH8 -3 198 0 0.2 ± 1.2 -0.6 ± 2.2 -11.9 ± 10.6 LL02664

RFH7 2 122 0 -0.3 ± 0.2 -0.1 ± 2.0 -17.4 ± 10.3 LL02665

RFH4 -3 245 0 -0.2 ± 0.2 2.4 ± 2.8 -4.9 ± 11.0 LL02666

RFH3 2 232 0 -0.4 ± 0.2 -2.0 ± 1.6 -2.2 ± 8.4 LL02667

RFH2 -3 228 0 0.3 ± 1.2 -0.1 ± 2.0 -9.3 ± 9.4 LL02668

RFH1 -8 215 0 0.4 t 1.2 -1.6 ± 1.0 -8.4 ± 9.3 LL02669

RFI1 2 131 0 0.2 ± 1.2 -0.6 ± 2.2 -8.9 ± 7.9 LL02670

RFI3 -8 76 0 -0.3 ± 0.2 0.8 ± 2.4 -8.5 ± 8.7 LL02671

RFI4 -13 147 0 -0.2 ± 0.2 1.0 ± 2.3 -7.7 ± 8.5 LL02672

RFI7 -13 109 0 -0.4 ± 0.2 2.5 ± 3.3 0.4 ± 8.9 LL02673

RFI8 -8 156 0 0.3 ± 1.2 -0.1 ± 2.0 -4.9 ± 8.6 LL02674

RFJ12 2 211 0 -0.2 ± 0.2 -0.3 ± 1.8 -8.5 ± 8.7 LL02675

RFJ9 2 22& 0 -0.4 ± 0.2 -1.1 ± 2.1 -7.7 ± 8.5 LL02676

RFJ8 -3 152 0 0.3 ± :1.2 1.7 ± 2.7 -8.3 ± 9.9 LL02677

RFJ6 .- 8 257 0 -0.2 ± 0.2 -0.7 ± 1.6 -9.6 ± 8.5 LL02678

RFJ5 2 198 0 -0.4 ± 0.2 -0.2 ± 2.4 -3.7 ± 8.5 LL02679

RFJ4 -13 147 0 -0.3 ± 0.2 -0.6 ± 1.8 -2.1 ± 8.2 LL02680

RFJ3 -3 257 0 -0.2 ± 0.2 0.2 ± 2.0 -12.9 ± 10.1 LL02681

RFJ1 -3 253 0 0.2 ± 1.2 -1.5 ± 1.9 -9.6 ± 8.5 LL02682

RFK1 -13 202 0 -0.3 ± 0.2 -1.0 ± 1.6 -10.5 ± 8.7 LL02683

RKF2 -3 219 0 0.4 ±' 1.2 1.0 ± 2.3 -6.9 ± 12.1 LL02684

RFK4 12 177 0 0.2 ± 1.2 1.6 ± 3.0 -8.6 ± 10.2 LL02685

RFK8 7 156 0 -0.3 ± 0.2 0.3 ± 2.2 -6.8 ± 8.9 LL02686

RKF9 2 245 0 0.4 ± 1.2 -0.7 ± 1.6 -2.3 ± 8.9 LL02687

RFK10 17 266 0 -0.4 ± 0.2 -0.6 ± 2.2 -6.1 ± 8.7 LL02688

RFK11 -8 236 0 -0.3 ± 0.2 0.8 ± 2.4 -6.7 ± 7.9 LL02689RFL10 -13 215 0 -0.2 ± 0.2 -1.2 ± 1.3 -5.8 ± 8.3 LL02690

RFL9 2 118 0 0.2 ± 1.2 -1.1 ± 2.1 -1.8 ± 9.2 LL02691

RFL7 -8 93 0 -0.3 ± 0.2 1.3 ± 2.6 -6.0 ± 8.5 LL02692

RFL6. -13 202 0 -0.2. ± 0.2 0.2 ± 2.0 -6.5 ± 8.4 LL02693

RFL5. -8 181 0 -0.4 ± 0.2 -1.1 ± 2.1 -9.3 ± 9.4 LL02694

RFL4 -13 186 0 -0.3 ± 0.2 3.5 ± 3.2 -5.7 ± 9.0 LL02695

RFL3 -13 194 0 1.0 ± 1.7 0.6 ± 2.2 -7.1 ± 10.1 LL02696

RFM5 -8 190 0 0.2 ± 1.2 1.2 ± 2.9 -3.8 ± 10.1 LL02697

RFM7 -8 109 0 0.3 ± 1.2 -0.6 ± 1.8 -10.2 ± 8.5 LL02698

RFM9 -13 198 0 -0.2 ± 0.2 2.8 ± 2.9 -7.2 ± 8.6 LL02699

RFN10 -13 131 0 0.2 ± 1.2 0.9 ± 2.4 -6.4 ± 10.1 LL02700

RFN9 -8 211 0 1.4 ± 2.0 1.4 ± 2.6 -7.5 ± 7.6 LL02701

RFN7 -8 169 0 -0.4 ± 0.2 -1.2 ± 1.5 -7.2 ± 9.4 LL02702

RFN5 -8 240 0 0.2 ± 1.2 -1.2 ± 1.5 -10.8 ± 8.9 LL02703

RFN2 7 215 0 -0.4 ± 0.2 0.1 ± 2.1 -9.3 ± 8.8 LL02704

RFN1 -3 169 0 -0.4 ± 0.2 0.5 ± 2.3 -1.8 ± 9.4 LL02705

RFO1 2 169 0 0.2 ± 1.2 0.1 ± 2.1 -11.8 ± 12.0 LL02706

RFO2 -3 240 0 -0.4 ± 0.2 -0.8 ± 1.7 -7.3 ± 10.4 LL02707

RFO3 -3 215 0 -0.4 ± 0.2 2.2 ± 2.8 -13.0 ± 14.3 LL02708

C-12-2

Page 89: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 7.-MH-4939-R-97, Facility Close-co-,andTermination Surv, Camj_ .1Imer, NJ, 1 Jul - 20 Dec 97 I

Camp Kilmer, BUILDING 1072 DOWNSTAIRS FLOOR RANDOMSLocation Monitoring -Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpmlO00cmA2 dpmnl00cm^2 uR/hr dpm/100cm^2 41- 2 sigma Number

(Bkgd >) 6 0.1 to 0.33 0.93 to 1.48 7.86 to 7.9(MDA=>) 52 227 - 2 2.14 * 42.48RFO5 -3 152 0 1.4 ± 2.0 0.9 ± 2.4 -23.9 ± 12.9 LL02709RFO6 7 114 0 0.8 ± 1.7 0.1 ± 2.1 -11.6 ± 8.6 LL02710RFO7 7 270 0 0.2 ± 1.2 2.7 ± 2.9 -2.1 ± 8.2 LL02711RFO9 2 131 0 0.8 ± 1.7 1.4 ± 2.6 -11.5 ± 8.0 LL02712RFO11 7 164 0 0.2 ± 1.2 0.9 ± 2.4 -1.2 ± 9.3 LL02713RFP12 -3 109 0 0.2 ± 1.2 2.7 ± 2.9 -15.0 ± 13.3 LL02714RFP5 -3 177 0 2.6 ± 2.6 3.1 ± 3.1 -11.3 ± 16.1 LL02715RFP1 -8 88 0 0.8 ± 1.7 0.9 ± 2.4 -15.2 ± 9.0 LL02716RFQ3 -8 101 0 0.2 ± 1.2 0.9 ± 2.4 -4.0 ± 8.9 LL02717RFQ4 -8 160 0 -0.4 ± 0.2 0.9 ± 2.4 -7.7 ± 8.5 LL02718RFQ6 -8 . 139 0 0.2 ± 1.2 0.5 ± 2.3 -8.7- ± 9.5 LL02719RFQ7 -8 160 0 0.8 ± 1.7 -0.3 ± 1.9 -7.0 ± 9.1 LL02720RFQ8 -13 232 0 0.2 ± 1.2 -0.3 ± 1.9 -14.9 ± 9.8 LL02721RFQ11 -3 232 0 0.2 ± 1.2 0.9 ± 2.4 -6.7 ± 9.5 LL02722RFQ12 -13 190 0 -0.4 ± 0.2 -1.2 ± 1.5 -11.4 ± 8.9 LL02723RFR12 2 143 0 -0.4 ± 0.2 0.5 ± 2.3 -10.6 ± 11.6 LL02724RFR10 7 253 0 0.2 ± 1.2 2.7 ± 2.9 -5.0 ± 10.0 LL02725RFR7 -13 249 0 0.2 ± 1.2 -0.3 ± 1.9 -10.5 ± 9.3 LL02726RFR6 2 139 0 -0.4 + 0.2 -0.8 ± 1.7 -11.9 ± 10.6 LL02727RFR5 2 232 0 -0.4 ± 0.2 -0.8 ± 1.7 -10.2 ± 9.3 LL02728RFR1 2 147 0 0.8 ± 1.7 1.8 ± 2.7 -7.0 ± 9.1 LL02729RFS1 2 122 0 0.2 ± 1.2 -1.6 ± 1.3 -11.2 ± 7.8 LL02730RFS4 -8 169 0 -0.4 ± 0.2 -0.3 ± 1.9 -7.2 ± 9.4 LL02731RFS5 12 105 0 -0.4 ± 0.2 -0.3 ± 1.9 -15.5 ± 9.7 LL02732RFS7 -8 177 0 0.8 ± 1.7 0.1 ± 2.1 3.4 ± 9.3 LL02733RFS9 -13 164 0 0.2-± 1.2 -2.1 ±, 1.0 -9.2 ± 10.1 LL02734RFS12 2 211 0 -0.4 ± 0.2 1.4 ± 2.6 -4.9 ± 9.7 LL02735RFT5 2 240 0 -0.4 ± 0.2 -1.2 ± 1.5 -11.9 ± 13.1 LL02736RFT4 -13 253 0 0.2 ± 1.2 0.5 ± 2.3 -9.2 ± 10.1 LL02737RFT3 -3 143 0 -0.4 ± 0.2 -1.2 ± 1.5 -4.5 ± 8.9 LL02738RFT2 -3 126 0 -0.4 ± 0.2 0.9 ± 2.4 -9.2 ± 7.6 LL02739RFT1 -13 156 0 0.8 ± 1.7 1.4 * 2.6 -2.5 ± 8.0 LL02740RFU2 -8 143 0 -0.4 ± 0.2 -0.8 ± 1.7 -10.2 ± 8.5 LL02741RFU3 -3 240 0 -0.4 ± 0.2 1.4 ± 2.6 -1.5 ± 7.7 LL02742RFU6 7 84 0 6.1 ± 3.9 7.0 ± 4.0 -7.0 ± 9.1 LL02743RFU7 -8 177 0 0.2 ± 1.2 0.5 ± 2.3 -10.2 ± 9.7 LL02744RFU8 -13 143 0 1.4 ± 2.0 0.1 ± 2.1 -3.7 ± 8.5 LL02745RFU9 -3 80 0 -0.4 ± 0.2 0.1 ± 2.1 0.3 ± 8.5 LL02746RFU11 2 59 0 6.7 ± 4.0 15.1 ± 5.4 -0.6 ± 8.4 LL02747RFU12 -13 109 0 0.2 ± 1.2 0.1 ± 2.1 -0.6 ± 8.0 LL02748RFV11 12 160 0 0.2 ± 1.2 3.1 ± 3.1 -5.5 ± 9.6 LL02749RFV8 -3 126 0 0.2 ± 1.2 0.5 ± 2.3 -6.7 ± 8.6 LL02750RFV6 -13 169 0 -0.4 ± 0.2 1.4 ± 2.6 -8.8 ± 8.4 LL02751RFV5 -3 93 0 0.2 ± 1.2 0.1 ± 2.1 -10.2 ± 8.5 LL02752RFV4 -8 76 0 1.4 ± 2.0 2.7 ± 2.9 -20.3 ± 12.7 LL02753RFV3 12 207 0 0.2 ± 1.2 -1.2 ± 1.5 -1.5 ± 7.9 LL02754RFV2 -3 160 0 0.2 ± 1.2 -0.8 ± 1.7 -3.5 ± 7.9 LL02755RFV1 -8 135 0 -0.4 ± 0.2 -0.3 ± 1.9 -5.3 ± 8.3 LL02756RFW1 -3 152 0 -0.4 ± 0.2 3.9 ± 3.3 -6.3 ± 8.9 LL02757RFW2 2 173 0 0.2 ± 1.2 0.1 ± 2.1 -8.7 ± 8.9 LL02758

C-1 2-3

Page 90: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2--MH-4939-R-97, Facility Close-o-1andTermination Surv, Camp limer, NJ, 1 Jul - 20 Dec 97 ..

Camp Kilmer, BUILDING 1072 DOWNSTAIRS FLOOR RANDOMS

Location Monitoring Wipe TestCode Alpha Beta Gamma Alpha Beta LS Wipe

(Units >) dpmnl00cmA2 dprnlOOcmA2 uRPhr dpmnlOOcmA2 +/-2 sigma Number

(Bkgd=>) 6 0.1 -- to 0.33 0.93 to 1.48 7.86 to 7.9

(MDA>) 52 227 - 2 2.14 42.48 1

RFW3 -3 131 0 -0.4 + 0.2 2.7 ± 2.9 -4.8 ± 8.4 LL02759

RFW4 -13 156 -1 -0.4 4 0.2 1.8 ± 2.7 -9.6 ± 9.1 LL02760

RFW6 -13 67 -1 0.2 ± 1.2 -0.8 ± 1.7 -11.5 ± 10.2 LL02761

RFW8 7 270 -1 -0.4 ± 0.2 -0.3 * 1.9 -7.8 ± 9.3 LL02762RFW12 -13 194 -1 0.8 4 1.7 0.1 ± 2.1 -9.1 ± 8.6 LL02763

Indicates the highest MDA for this survey unit. The Alpha MDA ranged from 1.93 to 2 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.91 to 2.14 dpm

Indicates the highest MDA for this survey unit. The H-3 MDA ranged from 14.48 to 42.48 dpm

C-12-4

Page 91: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R.-97., Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

Wall Numbers proceed clockwise in each room starting with thenorthern most wall.

C-13

Page 92: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

~N) )

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

ý 1 1 1 1 1 1 1 13 ,2

I I I f I I I I f I5 6 7

FFR ER 111111 III 1 11 11' ''1 1 !1!

I I I I I f f 1 11 11 1 if10

11

12

13

14

is

16

17

19 2018

BUILDING 1072. RANDOM WALLS. CAMP KILMER. NEW JERSEY nAT,- •n frT q7

DRAWN: MSD

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCALE: TrrSUNITED STATES ARMY MEDICAL DEPARTMENT

PLATE: NIA

C-14

Page 93: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, '1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 1072Wall Locatons

21 22 23 24

25 26 27 28 29 30

31 32 33 -... .. 35. 36 37 " 38";

39 40. 41 42

43 • 44 -:.. 45 46 47

) t l t l l l l l ~ llf II I Ii " I

48 49 so 51 52 53

54 55 56 57 58

59 so 61 62 63 64 65 66

67 68 69 70

71 72 73 74

75 76' 77 78

79 80

81 82

BUILDING 1072. RANDOM WALLS, CAMP KILMER. NEW JERSEY nA'r- 'in nT -7

DRAWN: MSD

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCALE: NTS

UNITED STATES ARMY MEDICAL DEPARTMENT PLATE:_WA

C-15

Page 94: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

$*

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

GRAPHICAL ILLUSTRATION

Building 1072Wall Locations

121 122 123 12a25 1 s 12 2

87 Be 89 9

I I ~ i t1 1 t111IL 1 1 F1-r -T T !H 1 1 1 1 1 1 1 1

921 92 0 94

95 96 97 98

1 99 10 1002 21 10

I I I f If I I I I I ! t 1I I I!01 i t 11t l

113 1 1 1 35 13 1

I. Ilt l lIlIll l l l l1 l117 ItItt l l l at19t1l

19 130 131 132

133 134 1 35 11511

III! 1!! IIt1! 1 t j-- +-H- -137 118 139 14010

14 2 1 23 144 145 14 6 147 1

129 1• 131147

BUILDING 1072. RANDOM WALLS, CAMP KILMER. NEW JERSEY MnIT, Q7nr,

DRAWN: MSO

U.S. ARMY CENTER FOR HEALTH PROMOTION APPROVED: HE

AND PREVENTIVE MEDICINE SCALE: NTS

UNITED STATES ARMY MEDICAL DEPARTMENTPLATE: N7A

C-16

Page 95: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-out andTermination Surv, Car'-K>(ilmer, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, BUILDING 1072 DOWNSTAIRS WALL RANDOMSLocation Monitoring Wipe Test

Code Alpha Beta Gamma Alpha Beta LS Wipe(Units =>) dpmnlOOcmA2 dprn1OOcmA2 uRlhr dpml'100cm^2 41- 2 sigma Number

(Bkgd =>) 6 0.1 to 0.33 0.88 to 1.16 7.86 to 7.9(MDA>) 52 227 - 1.96 1.93 20.56 *RWG24 7 105 0 -0.4 + 0.2 -0.3 k 1.9 -6.8 ± 7.5 LL02764

RWG61 -13 84 -1 0.2 ± 1.2 -0.8 ± 1.7 -3.2 ± 8.3 LL02765RWG213 7 8 -1 -0.4 ± 0.2 0.5 ± 2.3 -5.7 ± 7.4 LL02766RWG264 -13 8 -1 -0.4 ± 0.2 0.9 ± 2.4 1.6 ± 7.9 LL02767RWG272 -3 -5 -1 0.2 ± 1.2 -0.3 ± 1.9 -3.8 ± 7.5 LL02768

RWG326 -8 93 -1 -0.4 ± 0.2 0.1 ± 2.1 -1.0 ± 7.4 LL02769RWG426 -8 21 -1 0.2 ± 1.2 0.5 ± 2.3 -2.5 ± 8.0 LL02770RWG540 17 -106 -2 -0.4 ± 0.2 -1.2 ± 1.5 -12.4 ± 8.2 LL02771RWG563 2 12 -2 -0.4 ± 0.2 -0.3 ± 1.9 -7.4 ± 7.0 LL02772RWG466 2 29 -2 0.2 ± 1.2 1.4 ± 2.6 -2.4 ± 9.4 LL02773RWG525 -8 25 -1 -0.4 ± 0.2 0.1 ± 2.1 -2.4 ± 7.5 LL02774RWG583 2 84 -2 -0.4 ± 0.2 3.1 ± 3.1 -1.9 ± 7.4 LL02775RWG476 -3 114 -2 -0.4 ± 0.2 0.1 ± 2.1 9.8 ± 10.7 LL02776RWG535 7 38 -1 2.6 ± 2.6 1.5 ± 2.4 -4.9 + 7.7 LL02777RWG596 .- 3 21 -1 0.3 ± 1.2 2.0 ± 2.6 -2.4 ± 7.6 LL02778RWG653 7 42 -2 -0.3 ± 0.2 0.7 ± 2.1 -5.0 ± 7.9 LL02779RWG606 -13 63 -1 0.3 + 1.2 2.0 ± 2.6 -3.9 ± 7.6 LL02780RWG713 -3 -60" -1 -0.3 ± 0.2 0.7 ± 2.1 0.3 ± 7.9 LL02781RWG739 -13 71 -2 0.3 ± 1.2 -1.0 ± 1.3 -1.1 ± 8.0 LL02782RWG794 -3 -34 -2 -0.3 ± 0.2 0.3 ± 1.9 -3.9 ± 7.6 LL02783RWG763 -3 .50 -1 0.3 ± 1.2 -0.2 ± 1.7 1.8 ± 8.7 LL02784RWG920 23 388 1 -0.3 ± 0.2 2.4 ± 2.7 -3.8 ± 7.5 LL02785RWG990 2 59 -1 0.9 ± 1.7 0.7 ± 2.1 -7.5 ± 8.3 LL02786RWG1095 7 21 -1 0.3 ± 1.2 0.7 ± 2.1 -2.5 ± 8.0 LL02787RWG1334 -8 25 -1 0.9 ± 1.7 0.3 ± 1.9 -4.4 ± 7.8 LL02788RWG1344 7 -17 0 0.3 ±" 1.2 -1.0 ± 1.3 -1.5 ± 7.9 LL02789RWG1381 -3 126 -1 0.9 ± 1.7 0.3 ± 1.9 -4.4 ± 7.8 LL02790RWG1390 2 109 -1 -0.3 ± 0.2 1.5 ± 2.4 -0.6 ± 7.8 LL02791RWG1462 -8 55 .2 1.5 ± 2.0 2.8 ± 2.8 -3.4 ± 7.7 LL02792

RWG1553 -3 156 -2 -0.3 ± 0.2 1.1 ± 2.3 -4.6 ± 7.2 LL02793RWG1565 -8 80 -2 0.3 ± 1.2 3.3 ± 2.9 -3.7 ± 8.3 LL02794RWG1757 7 105 -1 -0.3 ± 0.2 2.4 ± 2.7 -4.1 ± 7.3 LL02795

RWG1849 17 63 -1 0.3 ± 1.2 2.8 ± 2.8 -1.5 ± 7.9 LL02796RWG1841 -3 126 -2 1.5 ± 2.0 1.5 ± 2.4 -1.1 ± 8.2 LL02797RWG2149 43 88 -1 -0.3 ± 0.2 2.8 ± 2.8 -5.5 ± 7.1 LL02798RWG2152 -8 122 -1 0.3 ± 1.2 1.1 ± 2.3 -0.1 ± 7.9 LL02799RWG2075 -3 88 -1 0.3 ± 1.2 -1.5 ± 0.9 1.7 ± 8.1 LL02800RWG2174 -8 29 -1 -0.3 ± 0.2 -0.2 ± 1.7 -2.7 ± 7.3 LL02801RWG2087 -8 63 -1 -0.3 ± 0.2 1.1 ± 2.3 -4.6 ± 7.2 LL02802RWG2442 17 -5 0 0.3 ± 1.2 0.7 ± 2.1 -4.1 ± 7.3 LL02803RWG2389 17 105 0 0.9 ± 1.7 -0.2 ± 1.7 3.9 ± 8.1 LL02804RWG2474 12 59 -1 -0.3 + 0.2 -0.6 ± 1.5 -6.7 ± 7.3 LL02805RWG2486 17 156 -1 -0.3 ± 0.2 0.3 ± 1.9 -6.4 ± 7.0 LL02806RWG2588 17 118 0 -0.3 ± 0.2 1.1 ± 2.3 5.3 ± 8.5 LL02807RWG2641 2 25 -1 -0.3 ± 0.2 2.0 ± 2.6 0.8 ± 8.0 LL02808RWG2649 12 38 -1 -0.3 ± 0.2 0.7 ± 2.1 -1.1 ± 7.8 LL02809RWG2675 -8 38 -1 -0.3 ± 0.2 -0.2 ± 1.7 0.3 ± 7.9 LL02810

RWG2820 -13 -9 0 -0.3 ± 0.2 0.3 ± 1.9 -5.1 ± 7.3 LL02811RWG2827 17 76 0 -0.3 ± 0.2 -0.2 ± 1.7 -5.0 ± 7.2 LL02812RWG2881 -3 67 0 -0.3 ± 0.2 1.5 ± 2.4 -5.1 ± 7.3 LL02813

C-16-1

Page 96: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radi Surv No. 2e Ki-4939-R-97, Facility Close-outznd

Termination Surv, Campi. liner, NJ, 1 Jul - 20 Dec 97

Camp Kilmer, UPSTAIRS RANDOMSLocation Monitoring Wipe Test'Code Alpha Beta Gamma Alpha Beta LS Wipe

(Units =>) dprm100cmA2 dpm/l00cm^n2 uR/hr dpm/100cmA2 +/- 2 sigma Number

(Bkgd >) 6 0.1 to 0.33 0.88 to 0.88 7.86 to 7.9

(MDA>) 52 227 - 1.94 1.83 19.31 *

RFA3 -8 63 -1 -0.3 ± 0.2 1.1 ± 2.3 -3.3 ± 8.8 LL02849

RFB2 -13 -98 -1 0.3 ± 1.2 0.3 ± 1.9 -10.7 ± 8.4 LL02850

RFC1 2 97 -1 -0.3 ± 0.2 2.8 ± 2.8 -7.5 ± 9.7 LL02851

RFF1 2 25 -1 0.3 ± 1.2 2.8 ± 2.8 -7.9 ± 8.0 LL02852

RFF3 2 891 -1 -0.3 ± 0.2 0.7 ± 2.1 -4.0 ± 8.9 LL02853

RWB4B -8 -5 -1 -0.3 ± 0.2 -0.6 ± 1.5 -6.2 ± 7.4 LL02854

RWE3C 2 38 -1 0.3 ± 1.2 -0.6 ± 1.5 -0.1 ± 7.9 LL02855

RWH1A -8 4 -1 -0.3 ± 0.2 1.5 ± 2.4 -1.5 ± 7.6 LL02856

RWJ2B 2 0 -1 -0.3 ± 0.2 0.3 ± 1.9 -2.4 ± 7.5 LL02857

RWN4C -8 -34 -1 -0.3 ± 0.2 1.1 ± 2.3 -3.3 ± 8.8 LL02858

Indicates the highest MDA for this survey unit. The Alpha MDA ranged from 1.94 to 1.94 dpm

Indicates the highest MDA for this survey unit. The Beta MDA ranged from 1.83 to 1.83 dpm

Indicates the highest MDA for this survey unit. The H-3 MDA ranged from 14.16 to 19.31 dpm

C-17-1

Page 97: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4', .-'R-97. Facility Close-out and Termination ourv, Camp Kilmer, NJ, 5 Nov -20 Dec 97

I''

K~)

00'-

0.

Arý

0

C-18-

Page 98: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-out and Termination Surv, Camp Kilmer, NJ, 5 Nov -20 Dec 97

DRMO Yard Survey Soil SamplesCamp Kilmer, NJ

Field InstrumentProject Identifier Base Sample Number Isotope Result Uncertainty Units MDA Exposure Rate

pRihr

CKLM BKGD#1 Alpha 3.93 (+1-) 1.19 PCI/G 0.68 13.2Beta 27.16 (+1-) 1.61 PCI/G 0.51

Ra-226 0.90 (+!-) 1.08 PCI/G 1.22Th-232 0.50 (+!-) 0.23 PCI/G 0.18U-238 0.00 (+/-) 0.00 PCIIG 0.77

CKLM BKGD#2 Alpha 4.21 (+!-) 1.21 PCIIG 0.59 16.0Beta 28.72 (+!-) 1.67 PCIIG 0.53

Ra-226 0.00 (+1-) 0.00 PCI/G 3.15Th-232 1.17 (+1-) 0.50 PCI/G 0.32U-238 0.00 (+1-) 0.00 PCI/G 1.94

CKLM BKGD#3 Alpha 3.70 (+1-) 1.13 PCI/G 0.60 16.2Beta 30.73 (+I-) 1.69 PCI/G 0.51

Ra-226 3.78 (+/-) 2.30 PCI/G 2.16Th-232 1.08 (+/-) 0.36 PCI/G 0.32U-238 0.00 (+1-) 0.00 PCI/G 1.44

CKLM BKGD#4 Alpha 3.63 (+1-) 1.13 PCI/G 0.59 16.4Beta 24.75 (+1-) 1.41 PCI/G 0.41

Ra-226 0.00 (+1-) 0.00 PCI/G 3.06Th-232 1.17 (+1-) 0.36 PCI/G 0.36U-238 0.00 (+1-) 0.00 PCIIG 1.76

CKLM BKGD#5 Alpha 3.60 (+1-) 1.15 PCI/G 0.68 15.3Beta 27.62 (+1-) 1.62 PCI/G 0.51

Ra-226 0.00 (+1-) 0.00 PCIiG 2.52Th-232 0.68 (+1-) 0.36 PCIIG 0.32U-238 0.00 (+/-) 0.00 PCI/G 1.44

Field InstrumentProject Identifier Base Sample Number Isotope Result Uncertainty Units MDA Exposure Rate

pJRhr

CKLM G-1 Alpha 3.36 (+1-) 1.12 PCI/G 0.68 13.7Beta 24.77 (+1-) 1.54 PCIIG 0.51

Ra-226 0.00 (+1-) 0.00 PCI/G 2.84Th-232 0.68 (+1-) 0.41 PCI/G 0.36U-238 0.00 (+1-) 0.00 PCIIG 1.49

CKLM G-2 Alpha 1.40 (+1-) 0.75 PCIIG 0.59 11.5Beta 21.82 (+1-) 1.47 PCI/G 0.53

Ra-226 0.00 (+1-) 0.00 PCIIG 2.79Th-232 0.00 (+1-) 0.00 PCI/G 0.45U-238 0.00 (+1-) 0.00 PCI/G 1.58

CKLM G-3 Alpha 4.98 (÷1-) 1.29 PCI/G 0.60 13.3Beta 27.60 (+1-) 1.61 PCI/G 0.51

Ra-226 0.00 (+1-) 0.00 PCIIG 2.79Th-232 0.00 (+/°) 0.00 PCI/G 0.50U-238 0.00 (+1-) 0.00 PCI/G 1.49

C-1 8-1

Page 99: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Sury No. 27-MH-49 .. 7, Facility Close-out and Termination .. ,

20 Dec 97Camp Kilmer, NJ, 5 Nov -

Field Instrument

Project Identifier Base Sample Number Isotope Result Uncertainty Units MDA Exposure RatepR/hr

CKLM G-4 Alpha 3.55 (+1-) 1.12 PCI/G 0.59 11.5Beta 15.49 (+1.) 1.14 PCI/G 0.41

Ra-226 0.00 (+1-) 0.00 PCIIG 2.21Th-232 0.00 (÷/-) 0.00 PCIIG 0.41U-238 0.00 (+1-) 0.00 PCIIG 1.22

CKLM G-5 Alpha 2.87 (+1-) 1.05 PCI/G 0.68 11.8Beta 21.97 (+/-) 1.46 PCI/G 0.51

Ra-226 0.00 (+1-) 0.00 PCI/G 2.61Th-232 0.00 (+/-) 0.00 PCI/G 0.45U-238 0.00 (+/-) 0.00 PCI/G 1.44

CKLM G-6 Alpha 2.89 (+1-) 1.02 PCI/G 0.59 12.1Beta 27.17 (+1-) 1.63 PCI/G 0.53

Ra-226 0.00 (+1-) 0.00 PCI/G 2.88Th-232 0.68 (+/-) 0.36 PCIIG 0.36U-238 0.00 (÷/-) 0.00 PCIIG 1.67

CKLM G-7 Alpha 2.82 (+1-) 1.00 PCIIG 0.60 10.0Beta 27.33 (+1-) 1.60 PCI/G 0.51

Ra-226 0.00 (÷/-) 0.00 PCIIG 2.75Th-232 0.54 (+/-) 0.36 PCI/G 0.32U-238 "0.00 (+1-) 0.00 PCI/G 1.44

CKLM G-8 Alpha 3.79 (+1-) 1.15 PCI/G 0.59 13.5Beta 31.19 (+!-) 1.57 PCI/G 0.41

Ra-226 0.00 (+/-) 0.00 PCI/G 2.84Th-232 1.31 (+1-) 0.54 PCI/G 0.41U-238 2.93 (+!-) 1.62 PCI/G 1.58

CKLM G-9 Alpha 3.68 (+/-) 1.16 PCI/G 0.68 9.6Beta 28.70 (+1-) , 1.65 PCIIG 0.51

Ra-226 2.34 (+!-) 2.03 PCIIG 2.70Th-232 0.99 (+/-) 0.36 PCI/G 0.32U-238 0.00 (+1-) 0.00 PCIIG 1.76

CKLM G-10 Alpha 2.14 (+/-) 0.90 PCIIG 0.59 12.2Beta 25.12 (+1-) 1.57 PCI/G 0.53

Ra-226 0.00 (+/-) 0.00 PCIIG 3.02Th-232 0.00 (+1-) 0.00 PCIIG 0.54U-238 0.00 (+1-) 0.00 PCI/G 1.53

CKLM G-11 Alpha 2.46 (+1-) 0.98 PCI/G 0.68 12.6Beta 18.39 (+1-) 1.35 PCIIG 0.51

Ra-226 0.00 (+1-) 0.00 PCIIG 2.79Th-232 0.68 (+/-) 0.41 PCIIG 0.32U-238 0.00 (+1-) 0.00 PCIIG 1.85

CKLM G-12 Alpha 4.21 (41.) 1.21 PCIIG 0.59 12.1Beta 26.60 (+1-) 1.61 PCI/G 0.53

Ra-226 0.00 (+1-) 0.00 PCI/G 3.11Th-232 0.50 (+1-) 0.36 PCI/G 0.41U-238 0.00 (+1-) 0.00 PCI/G 2.03

C-1 8-2

Page 100: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn-Surv No. 27-MH-49:5,-R-97, Facility Close-out and Termination burv,20 Dec 97

Camp Kilmer, NJ, 5 Nov-

Field InstrumentProject Identifier Base Sample Number Isotope Result Uncertainty Units MDA Exposure Rate

I _pR/hr

CKLM G-13 Alpha 3.62 (+/-) 1.12 PCIIG 0.60 11.2Beta 26.74 (+1-) 1.59 PCIIG 0.51

Ra-226 2.88 (+1-) 2.75 PCIIG 2.52Th-232 0.86 (+/-) 0.45 PCIIG 0.36U-238 0.00 (+1-) 0.00 PCIIG 2.03

CKLM G-14 Alpha 2.55 (+/-) 0.96 PCIIG 0.59 12.6Beta 22.68 (+1-) 1.35 PCI/G 0.41

Ra-226 0.00 (.1-) 0.00 PCIIG 3.11Th-232 1.04 (+!-) 0.45 PCI/G 0.36U-238 0.00 (+/-) 0.00 PCI/G 2.03

CKLM G-15 Alpha 3.03 (+1-) 1.07 PCIIG 0.68 13.1Beta 23.41 (+1-) 1.50 PCI/G 0.51

Ra-226 0.00 (+1-) 0.00 PCI/G 3.02Th-232 0.00 (+!-) 0.00 PCI/G 0.54U-238 0.00 (+1-) 0.00 PCIIG 2.12

CKLM G-16 Alpha 3.22 (+1.) 1.07 PCI/G 0.59 8.2Beta 27.61 (+1-) 1.64 PCI/G 0.53

Ra-226 0.00 (+1-) 0.00 PCI/G 3.15Th-232 0.00 (+/-) 0.00 PCI/G 0.63U-238 0.00 (+--) 0.00 PCI/G 2.12

CKLM G-17 Alpha* 4.66 (+!-) 1.25 PCI/G 0.60 10.9Beta 25.93 (+/-) 1.56 PCI/G 0.51

Ra-226 0.00 (+1-) 0.00 PCI/G 3.15Th-232 0.63 (+1-) 0.41 PCIIG 0.50U-238 0.00 (+1-) 0.00 PCI/G 2.12

CKLM G-18 Alpha 3.71 (+1-) 1.14 PCI/G 0.59 10.8Beta 18.56 (+!) 1.23 PCIIG 0.41

Ra-226 0.00 (+/-) 0.00 PCI/G 2.93Th-232 0.00 (+!-) 0.00 PCIlG 0.50U-238 0.00 (+1-) 0.00 PCIIG 1.94

CKLM G-19 Alpha 3.36 (+!-) 1.12 PCI/G 0.68 9.2Beta 18.89 (4/-) 1.36 PCIIG 0.51

Ra-226 0.00 (+1-) 0.00 PCI/G 2.88Th-232 0.54 (+/-) 0.36 PCI/G 0.32U-238 0.00 (+!-) 0.00 PCI/G 1.98

CKLM G-20 Alpha 2.39 (+!-) 0.94 PCIIG 0.59 10.6Beta 19.35 (+/-} 1.40 PCIIG 0.53

Ra-226 0.00 (+1-) 0.00 PCI/G 3.06Th-232 0.00 (+1-) 0.00 PCI/G 0.54U-238 0.00 (+1-) 0.00 PCI/G 2.07

CKLM G-21 Alpha 4.18 (+/-) 1.23 PCIIG 0.68 10.5Beta 20.20 (+!-) 1.41 PCIIG 0.51

Ra-226 2.34 (+1-) 0.95 PCI/G 0.81Th-232 0.50 (+/-) 0.23 PCI/G 0.18U-238 0.00 (+1-) 0.00 PCI/G 0.72

C-1 8-3

Page 101: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-493' .-9 7 , Facility Close-out and Termination Camp Kilmer, NJ, 5 Nov -20 Dec 97

Field InstrumentProject Identifier Base Sample Number Isotope Result Uncertainty Units MDA Exposure Rate

_PR/hr

CKLM G-22 Alpha 5.53 (+1-) 1.37 PCI/G 0.59 9.7Beta 31.94 (+1-) 1.76 PCIIG 0.53

Ra-226 0.59 (+1-) 0.68 PCI/G 0.59Th-232 0.18 (+/-) 0.14 PCI/G 0.09U-238 0.41 (+1-) 0.50 PCI/G 0.41

CKLM G-23 Alpha 2.18 (+/-) 0.90 PCI/G 0.60 7.4Beta 25.68 (+1-) 1.55 PCIIG 0.51

Ra-226 1.17 (+1-) 0.72 PCIIG 0.63Th-232 0.32 (+/-) 0.18 PCIIG 0.14U-238 0.00 (+1-) 0.00 PCI/G 0.63

CKLM G-24 Alpha 2.39 (+1-) 0.94 PCIIG 0.59 8.8Beta 13.23 (+/°) 1.06 PCIIG 0.41

Ra-226 2.07 (+1-) 0.72 PCI/G 0.63Th-232 0.18 (+/-) 0.18 PCI/G 0.14U-238 0.00 (+1-) 0.00 PCIIG 0.63

CKLM G-25 Alpha 2.87 (+/-) 1.05 PCIIG 0.68 7.9Beta 15.20 (+1-) 1.24 PCI/G 0.51

Ra-226 1.62 (+/-) 0.81 PCIIG 0.63Th-232 0.27 (+1-) 0.18 PCI/G 0.09U-238 0.00 (÷1-) 0.00 PCI/G 0.63

CKLM G-26 Alpha 2.14 (+1-) 0.90 PCI/G 0.59 9.2Beta 19.89 (+1-) 1.41 PCIIG 0.53

Ra-226 1.13 (+1-) 0.72 PCIIG 0.63Th-232 0.32 (+1-) 0.18 PCIIG 0.14U-238 0.00 (÷1-) 0.00 PCI/G 0.59

CKLM G-27 Alpha 4.18 (.1-) 1.19 PCI/G 0.60 8.6Beta 22.18 (+1-) 1.45 PCIIG 0.51

Ra-226 1.49 (÷1-) 0.72 PCI/G 0.50Th-232 0.00 (+1-) 0.00 PCIIG 0.18U-238 0.00 (+1o) 0.00 PCIIG 0.45

CKLM G-28 Alpha 3.13 (+1-) 1.05 PCI/G 0.59 9.2Beta 17.97 (+!-} 1.22 PCIIG 0.41

Ra-226 1.62 (+!-) 0.90 PCI/G 0.68Th-232 0.63 (+1-) 0.23 PCI/G 0.14U-238 0.00 (÷1-} 0.00 PCIIG 0.68

CKLM G-29 Alpha 4.34 (÷!-) 1.25 PCIIG 0.68 10.1Beta 21.35 (÷1-) 1.44 PCI/G 0.51

Ra-226 1.26 (+1-) 0.90 PCI/G 0.72Th-232 0.00 (+1-) 0.00 PCIIG 0.23U-238 0.00 (+1-) 0.00 PCI/G 0.68

CKLM G-30 Alpha 2.72 (+1-} 0.99 PCI/G 0.59 10.0Beta 15.09 (+1-) 1.25 PCI/G 0.53

Ra-226 1.22 (+1.) 0.81 PCI/G 0.63Th-232 0.23 (+/.) 0.18 PCIIG 0.14U-238 0.00 (+1-) 0.00 PCIIG 0.59

C-18-4

Page 102: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul -20 Dec 97

APPENDIX D

RELEASE GUIDELINES

D-1

Page 103: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

..Th

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

Accentable Surface Contamination Levels

Nuclides' Averageb"c"' Maximumbd, f Removable be° f

(dpm/l00cm2 ) (dpm/10Ocm 2 ) (dpm/100ocm 2)

U-Nat, 235U, 23'U, and associated 5,000 cY 15,000 a 1, 000 aproducts

Transuranics, 226 Ra, 228 Ra, 230 Th, 100 300 20228Th, 23'Pa, 227Ac, 1251, 1291

Th-nat, 232Th, °S r, 22 Ra, 224Ra, 1,000 3,000 200232 U, 1261, 1311, ;331

Beta/gamma emitters(nuclides 5,000 0Y 15,000 Oy 1,000 PYwith decay modes other thanalpha emission orspontaneous fission) except90Sr and other noted above

a-4 Where surface contamination by both alpha- and beta/gamma-emittingnuclides exists, the limits established for alpha-and beta/gamma-emittingnuclides should apply independentlyb-4 As used in this table dpm (disintegrations per minute) means the rate ofemission by radioactive material as determined by correcting the counts perminute observed by an appropriate detector for background, efficiency, andgeometric factors associated with the instrumentation.c-4 Measurements of average contaminant should not be averaged over more than1 square meter. For objects of less surface area, the average should bederived for each such objectd-4 The maximum contamination level applies to an area of not more than 100 cm2

e-4 The amount of removable radioactive material per 100 cm2 of surface areashould be determined by wiping that area with dry filter or soft absorbentpaper, applying moderate pressure, and assessing the amount. of radioactivematerial on the wipe with an appropriate instrument of known efficiency. Whenremovable contamination on objects of less surface area is determined, thenpertinent levels should be reduced proportionally and the entire surfaceshould be wiped.f-b The average and maximum radiation levels associated with surfacecontamination resulting from beta-gamma emitters should not exceed 0.2 mrad/hrat 1 cm and 1.0 mrad/hr at 1 cm, respectively, measured through not more than7 milligrams per square centimeter of total absorber.

Reference: Guidelines for Decontamination of Facilities and Equipment prior toRelease for Unrestricted use or Termination of Licenses for Byproducts,Source, or Special Nuclear Material., U.S. Nuclear Regulatory Commission,April 1993.

D-2

Page 104: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul 20 Dec 97

APPENDIX E

INSTRUMENTATION USED AT Camp Kilmer

E-1

Page 105: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

Instrumentation used at Camp KilmerTermination Survey

Alpha Beta Gamma

Readout Make LUDLUM LUDLUM LUDLUM

Readout Model 2350 2350 2350

Serial Number 117572 117577 117030

Cal. Date 2 Oct 97 2 Oct 97 2 Oct 97

Probe Make LUDLUM LUDLUM LUDLUM

Probe Model 43-68 43-68 44-2Serial number PR120560 PR122127 RN133850

Instrumentation used at Camp KilmerTermination Survey

BETA GAMMA SCANNER

Readout Make LUDLUM LUDLUM LUDLUM

Readout Model 2350 2350 2224

Serial Number 117576 120615 118238

Cal. Date 2 Oct 97 2 Oct 97 27 Oct 97

Probe Make LUDLUM LUDLUM LUDLUM

Probe Model 43-68 44-2 43-37-1

Probe Serial PR122121 RN133843 122885Number

All instrumentation was supplied by USACHPPM and the calibration is traceable tothe National Institute of Standards and Technology.

E-2

Page 106: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

APPENDIX F

QUALITY ASSURANCE RESULTS

F-I

Page 107: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out aindTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

1. Spiked Samples. See table below.

Tritium Spikes

Position Identification Lab ID DPM DPM Percentadded found Recovery

H-3 LL00101 119 0 -1.15 N/A

H-3 LL00202 120 997 978 98.1%

H-3 LL00303 121 499 433 86.8%

H-3 LL00404 122 249 244 98.0%

H-3 LL00505 123 997 938 94.1%

H-3 LL00606 124 0 -. 15 N/A

H-3 LL01265 125 997 971 97.4%

H-3 LL01320 127 997 1003 100.6%

H-3 LL02235 128 0 -4.15 N/A

H-3 LL02554 126 499 488 97.8%

Note: Each sample vial was packed inside a second vial toprotect from spread of contamination if broken.

a. The percent recovery of the samples was within therecommended plus or minus 20 percent (80% to 120%). The averagepercent recovery was 96.1% and had a range of 86.8% to 100.6%.

2. Blank Wipe Samples. Survey teams randomly submitted blanksamples to the laboratory. Samples LL00101, LL00606, and LL02235were submitted as a blank. The blank sample had no detectableactivity above the detection limit.

F-2

Page 108: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

)

Indust Radn Surv No. 27-MH-4939-R-97, Facility Close-Out andTermination Survey, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

APPENDIX G

INSTRUMENT QUALITY ASSURANCE CHARTS

G-1

Page 109: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27--"-4939-R-97, Facility Clos--out andTer,,iination Surv, Camp 1 .)er, NJ, 1 Jul_ - 20 Dec £

Instrument Control Chart

InstrumentQCID:

Meter Serial #: 117030Meter Make I Model #: LUDLUM 2350QCDateTime: 11/18/97 7:48:57 AMSurveyor: Lorus Miller

3

Probe Serial #: 133850GProbe Make I Model # 44-2

Check Source IsotopeSerial NumberActivity

30

Cs-1372031-95

1978020Background:

Mean:StdDev:2StdDev:3StdDev:

560.218.336.554.8

5.4 CPM

# Data Points

523.7505.4

DPM

596.8615.0

Count Time:

Instrument Efficiency:

60

-100.00%

Instrument QC Data:1 569 60 uRlhr 13 558 60 uRlhr 25 534 60 uRPhr2 589 60 uRPhr 14 593 60 uRPhr 26 553 60 uRPhr

3 561 60 uRPhr 15 561 60 uR/hr 27 570 60 uR/hr

4 578 60 uRPhr 16 565 60 uRlhr 28 576 60 uRPhr5 555 60uRPhr 171 612 60uRPhr 29 -554 60 uR/hr

6i 565 60 uR/hr 18 577 60 uRlhr 1 30 560 60 uPlhr7 589 60 uR/hr 19 -' 533 60 uR/hr8 575 60 uRPhr 201 579 60 uRPhr

.9 540 60 uR/hr 211 565 60 uRlhr

10 566 60 uRlhr 22 580 60 uRlhr

11 578 60 uRlhr 23 547 60 uR/hr

12 544 60 uRlhr 24 542 60 uR/hr

700.

Control Chart600

500

400

300

200

100

0

-- - - - - - - - -7 -p -p -p ~ p-p -p p -p - -- Net Reading

-U--Mean3N 2StdDev+

-X- 2StdDev--*- 3StdDev+-- O-3StdDev-

G-2-1 Printed: 314/98 2:36:16 PM

Page 110: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27, 1-4939-R-97, Facility Clo. .-out and

Termination Surv, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

Instrument Control Chart

InstrumentQCID:

Meter Serial #: 117572

Meter Make I Model #: LUDLUM 2350

QCDateTime: 11/18/97 10:49:58 AMSurveyor: Lotus Miller

4

Probe Serial #: .1 120560A

Probe Make I Model , 43-68A

Check Source Isotope Th-230Serial Number 2029-95ActivityBackground:

Mean:StdDev:2StdDev:3StdDev:

2.6 CPM

# Data Points

7180 DPM

1411.633.366.699.9

30

1345.01311.7

1478.2-1511.5

Count Time:

Instrument Efficiency:

60

19.66%

Instrument QC Data:1 1342 60 Counts 13 1429 60 Counts 25 1467 60 Counts

2 1369 60 Counts 14 1367 60 Counts 26 1453 60 Counts

3 1368 60 Counts 15 1428 60 Counts 27 1417 60 Counts

4 1423 60 Counts .. 16 1458 60 Counts 28 1383 60 Counts

5 1403 60 Counts 17 1385 60 Counts 29 1449 60 Counts

6 1440 60 Counts 18 14131 60 Counts 30 1416 60 Counts

7 1479 60ICounts 19 1448 601Counts8 1429 60 Counts 20 ._1436 60 Counts

9 1407 60 Counts 21 1439j 60 Counts

10 1416 60 Counts 22 1398 60 Count

11 1407 60 Counts 23 1383 60 Counts

12 1402 60 Counts 24 1371 60 Counts

1550

1500

1450

1400

1350

1300

1250

1200

1-- - - - - - - - - - - - -

Control Chart

-4---Net Reading

- Mean

3N 2StdDev+-*-- 2StdDev-

* 3StdDev+-- 3StdDev-

E-Wqr --,r V V V

I

.............................k ft) 'b -1, -1 kN N-, Nn -,-ý N% '1ý '0' "P ý P

G-3-1 Printed: 3/4198 2:30:43 PM

Page 111: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

.Indu!t Radn Surv No. -27&-.4939-R--97T,--Facility Close-out and

Termination Surv, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

Instrument Control Chart

InstrumentQCID:

Meter Serial #: 117577Meter Make I Model #: LUDLUM 2350QCDateTime: 11/18/97 1:58:22 PMSurveyor: Lotus Miller

5

Probe Serial #: 122127B

Probe Make I Model # 43-68B

Check Source Isotope Tc-99Serial Number 2030-95Activity

30

Background: 212.5 CPM

# Data Points

8050 DPM

Mean:StdDev:2StdDev:3StdDev:

1998.335.971.7

107.61926.61890.7

2070.02105.9

Count Time:

Instrument Efficiency:

60

24.82%

Instrument OC Data:1 2285 60 Counts 13 2236 60 Counts 25 2257 60 Counts2 2180 60 Counts 14 2221 60 Counts 26 2240 60 Counts3 2190 60 Counts 15 2166 60 Counts 27 2210 60 Counts

4 2269 60 Counts. 16 2189 60 Counts 28 2220 60 Counts5 2176 60 Counts 17J.- 2223 60 Counts 29 2223 60 Counts

6 2154 60 Counts 18 2214 60 Counts 30 22561 60 Counts

7 2193 60 Counts 19 2153 60oCounts8 2226 60 Counts 20 . 2194 60 Counts9 2208 60 Counts 21 2183 60 Counts

10 2214 60 Counts 22 2192 60 Counts11 2237 60 Counts 23 2208 60 Counts12 -2141, 60 Counts 24 2266 60 Counts

2150

2100 W W K W )K N 1 W X W W NE W W N W X W NE X W X

2000o ... Z.... . .... . . .Control Chart

-- Net Reading---- Mean

* 2Std De v+*2Std Dev-

* 3StdDev+-I - 3StdDev-1950.

1900.

1850.

1800.

17501N lb 1b A Cý NN 41 41 N11 |1 lp %A J . .p=. i

G-4-1 Printed: 3/4198 2:31:18 PM

Page 112: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27.. )-4939-R-97, Facility- Clo'... -out and

Termination Surv, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

Instrument Control Chart .1

InstrumentQCID:

Meter Serial #: 117576

Meter Make I Model #: LUDLUM 2350

QCDateTime: 11125197 9:39:22 AMSurveyor. Lorus Miller

6

Probe Serial #: 122121BProbe Make I Model # 43-68

Check Source Isotope

Serial NumberActivity

30

Tc-992030-95

Background:

Mean:StdDev:2StdDev:3StdDev:

120.1 CPM

# Data Points

8050 DPM

1904.947.995.8

143.71809.11761.2

2000.7,2048.6

Count Time:

Instrument Efficiency:

60

23.66%

Instrument QC Data:1 1966 60 Counts 13 2076 60 Counts 25 2030 60 Counts2 2011 60 Counts. 14 2065 60 Counts 26 2060 60 Counts3 2076 60 Counts 15 1961 60 Counts 27 2074 60 Counts4 2021 60 Counts 16. 2064 60 Counts 28-- 2066 60 Counts5 2031 60 Counts 17 2060 60 Counts 29 20631 60 Counts6 1999 60 Counts 18 20461 60 Counts 1 .30 20521 60 Counts7 2025 601Counts 19 1920 60oCounts.8 2000 60 Counts 20 2098 60 Counts9 1937 60 Counts 21 2020 60 Counts

10 1950 60 Counts 22 2076 60 Counts11 1968 60 Counts 23 .1962 60 Counts12 2032 60 Counts 24 2041 60 Counts

2100

2050 K

2000 -- -. .. -. . . . . . . . . . . . . . . . . . . . . .

19501 A ~ hA

Control Chart

"VUUu

1850,

1800.

1750.

1700.

1650.

7 -!T~EENEU~UU~r77EE\E/E777

.aamamm. mamma. mammmmamaaam mm

1600.. ..............................f b k q -, , b - b . - b 1 P P 'P

G-5-1 Printed: 3/4/98 2:31:55 PM

Page 113: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Ind;.st Radn Surv No. 2 7 h•-4939-R-97, Facility Clir.out and

Termination Surv, Camp kilmer, NJ, 1 Jul - 20 Dec 97

Instrument Control Chart

InstrumentOCID:

Meter Serial #: 120615

Meter Make I Model #: LUDLUM 2350

QCDateTime: 11(29/97 2:01:43 PMSurveyor: Lotus Miller

8

Probe Serial #: 133843G

Probe Make I Model # 44-2

Check Source IsotopeSerial NumberActivity

30

Cs-1372031-95

1978020Background:

Mean:StdDev:2StdDev:.3StdDev:

5.5 CPM DPM

547.015.631.146.7

# Data Points

515.9500.3

578.1593.7

Count Time:

Instrument Efficiency:

60

-100.00%

Instrument QC Data:1 555 60 uR/hr 13 572 60 uRPhr 25 550 60 uR/hr2 571 60 uR/hr 14 550 60 uRPhr 26 545 60 uRPhr3 562 60 uRlhr 15 564 60 uRPhr 27 529 60 uR/hr4 569 60 uRPhr 16 561 60 uRlhr 28 565 60 uRPhr

5 561 60 uRfhr 17 541 60 uRlhr 29 542 60 uR/hr6 531 60 uPlhr 18 532 60uRPhr 30 547 61uR/hr

7 556 60 uRthr 19 5721 60luR/hr8 534 60 uR/hr 20 555 60 uR/hr

9 511 60 uR/hr 21 573 60 uR/hr

10 547 60 uR/hr 22 555 60 uR/hr

11 560 60 uRPhr 23 533 60 uRlhr

12 562 60 uPRhrJ 24 569 601 uRhr

620

600]

580.-

560.

540.

520.

500

480.

460.

EX X )El X X XX X XXX

Control Chart

-- Net Reading-- Mean

- 2StdDev+

---- 2StdDev-

W-- 3StdDev+-e- 3StdDev-

440....... . . I.... .. .

N b < % 1 N 45 4b N lb 1ýl ý l

G-6-1 Printed: 3/4/98 2:32:22 PM

Page 114: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 27-.1H-4939-R-97, Facility Close-out andTermination Surv, Camp Kilmer, NJ, I Jul - 20 Dec 97

Instrument Daily Control Chart

InstrumentQCID:

Meter Serial M: 117030Meter Make I Model #: LUDLUM 2350

QCDateTime: 11118/977:48:57 AMSurveyor: Lorus MillerBackground: 5.4 CPM

3

Probe Serial #: 133850GProbe Make I Model # 44-2

Check Source Isotope Cs-1 37Serial Number 2031-95Activity 1978020 DPM

.30Mean:StdDev:2StdDev:3StdDev:

560.2 # Data Points18.336.554.8

523.7505.4

596.8615.0

Count Time:

Instrument Efficiency:

60

-100.00%

Instrument QC Data:11118197 8:16:05 AM 562.3 AM 11/21197 9:14:51 PM 565 PM

11118/97 12:07:02 PM 568.5 MidDay 11/24/97 6:15:47 AM 569 AM

11 /18197 4:45:46 PM 548.1 PM 11/24/97 12:18:46 PM 555 MidDay

11/19197 6:37:02 AM 569.2 AM 11/24/97 7:32:50 PM 562 PM

11119197 12:00:54 PM 562 MidDay 11/25/97 6:03:55 AM 547 AM

11/19/97 6:07:26 PM 573 PM 11125197 12:43:29 PM 537 _ MidDay

11/20197 6:09:19 AM 561 AM 11/25197 7:44:20 PM 575 PM

1120/97 12:11:38 PM 528 MidDay 11/26/97 6:05:09 AM 566 AM

11/20/97 8:12:23 PM 554 PM 11/26197 12:21:41 PM 562 MidDay

11/21/97 6:13:14 AM 564 AM 11126/97 7:26:14 PM 552 PM

11/21/97 12:14:05 PM 553 MidDay

700

600 (____Control Chart

500

400.

300.

200.

100.

0

m~~ ~ -w- -w-- a- m m umwm m | mW --- 0

ro P sp 4b .11), Nt, .. "b Uftj 21ý ýbf6* Cb* fir* rb.

11% Ilk IN 4q k A

41V \V 41P

G-7-1 Printed: 3/4/98 2:40:15 PM

Page 115: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

nu Radn urv No.-4939-R-97, Facility Clo..or-out andTermination Surv, Camp Kilmer, NJ, 1 Jul - 20 Dec 97

4. Instrument Daily Control ChartInstrumentQCID:

Meter Serial #: 117572

Meter Make I Model #: LUDLUM 2350

QCDateTime: 11118197 10:49:58AMSurveyor Lorus MillerBackground: 2.6 CPM

4

Probe Serial #: 120560A

Probe Make I Model # 43-68A

Check Source IsotopeSerial NumberActivity

30

Th-2302029-95

7180 DPM

Mean:StdDev:2StdDev:3StdDev:

1411.6 # Data Points33.366.699.9

1345.01311.7

1478.21511.5

Count Time:

Instrument Efficiency:

60

19.66%

Instrument QC Data:11118/97 8:20:52 AM 1420 AM... 11/211977:09:32PM 1438 PM

11118/97 12:21:12 PM 1414 MidDay 11/24/97 6:19:23 AM 1445 AM

11/18197 4:43:18 PM 1450 PM 11/24/97 12:12:18 PM 1464 MidDay

11/19197 6:44:26 AM 1465 AM 11/24197 7:15:41 PM 1448 PM11119197 7:45:32 PM 1356 PM 11/25/97 6:15:53 AM 1425 AM11/20197 6:14:27 AM 1402 AM 11/25197 12:16:02 PM 1435 MidDay

11/20/97 12:17:06 PM 1456 MidDay 11/25/97 8:16:12 PM 1400 PM

11/20197 7:18:02 PM 1424 PM 11/26197 6:11:18 AM 1425 AM11/21/97 6:19:21 AM 1448 AM 11/26/97 1:16:39 PM 1450 MidDay

11/21197 12:05:18 PM 1434 _____MidDay 11/26197 7.35:45 PM 1453 PM

11/21/97 12:17:46 PM 1429 MidDay 11/29197 6:11:50 AM 1354 AM

1550

Control Chart1500 -¶ •. . . . . ..?• •- •- - . . . . ... ...

- -------------------- -------- -4-eedn1450 Mean

2StdDev+

1400 X ------------ -- -U-- 2Std~ev-

-*- 3StdDev+1350 : < ¢. .; .. < .,.X×;"; .. . .. .. . . . -- *--3StdDev-

•1300 0 - OSSS 0 0 -0 . - p p p p

1250

1200

tv - x -111h .4k, NN A'ý%& Up &

N\ý'j 41 CP "\-O '41 4 6N "K,N

G-8-1 Printed: 3/4/98 2:40:46 PM

Page 116: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2" ' -4939-R-97, Facility CI.' Lout andTermination Surv, Camp 'Kilmer, NJ, 1 Jul - 20 Dec 97

Instrument Daily Control Chart

InstrumentQCID:

Meter Serial #: 117577

Meter Make I Model #: LUDLUM 2350

QCDateTime: 11/18/97 1:58:22 PM

Surveyor. Lotus MillerBackground: 212.5 CPM

5

Probe Serial #: 1221278

Probe Make I Model # 43-68B

Check Source Isotope Tc-99Serial Number 2030-95Activity

30

8050 DPM

Mean:StdDev:2StdDev:3StdDev:

1998.3 # Data Points35.971.7

107.61926.61890.7

2070.02105.9

Count Time:

Instrument Efficiency:

60

24.82%

Instrument QC Data:11118/97 8:48:29 AM 2018 AM 11121/97 12:24:15 PM 1988 MidDay

11118197 12:50:21 PM 1957 MidDay 11/24/97 6:25:50 AM 1961 AM

11/18/97 5:51:32 PM 2036 PM 11/2419711:41:56AM 1957 MidDay

11119/97 6:04:01 AM 2006 AM 11/24/97 7:02:39 PM 1959 PM

11/19/97 11:55:31 AM 19521 MidDay11119197 8:57:35 PM 1973 PM

11/20197 6:08:43 AM 1963 AM

11/20/97 12:04:05 PM 2005 MidDay

11/20197 7:55:11 PM 1964 PM

11/21/97 6:05:58 AM 1941 AM

1121/97 7:24:26 AM 1959 PM

2150

2100 Control Chart

2050

2000

1950

1900

1850

1800

-4- Net Reading

-U-GMean6 2StdDev+

--- 2Std De v-W 3StdDev+

"--4-- 3StdDev-

1750

tý Al A A 'Zý .4ý 01 'IýA

zO \'41 -AKKV

G-9-1 Printed: 314198 2:41:17 PM

Page 117: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2' iH-4939-R-97, Facility ClJ'-out and,Ter3mination Surv; Camp-,rimer, NJ, 1 Jul - 20-Dec !,7

Instrument Daily. Control Chart

lnstrumentQCID:

Meter Serial #: 117576Meter Make I Model #: LUDLUM 2350QCDateTime: 11/25197 9:39:22 AMSurveyor: Lorus MillerBackground: 120.1 CPM

6Probe Serial #: 122121BProbe Make I Model # 43-68

Check Source Isotope Tc-99Serial Number 2030-95Activity

30

8050 DPM

Mean:StdDev:2StdDev:3StdDev:

1904.9 # Data Points47.995.8

143.71809.11761.2

2000.72048.6

Count Time:

Instrument Efficiency:

60

23.66%

Instrument QC Data:11125/97 6:15:12 AM 1935 AM 1211197 6:17:48 PM 1839 PM

11/25/97 12:12:16 PM 1928 MidDay 12/2197 6:11:55 AM 1882 AM

11/25197 8:16:57 PM 1909 PM 1212/97 12:13:02 PM 1825 MidDay11/26/97 6:11:03 AM 1976 AM 12/2/97 5:14:06 PM 1868 PM

11 /26197l 1:16:09 PM 1946 MidDay11/26197 7:35:50 PM 1952 PM

11/29/97 6:11:17 AM 1972 AM

11/29/97 1:23:27 PM 1866 MidDay

11129197 8:17:32 PM 1956 PM

1211/97 6:07:37 AM 1853 AM

12/11/97 1:17:44 PM 1857 IMidDay

21002fl5O 1

Co~ntrol Ch~rt

2O00,--~ •~-NetReading

1950 -- Mean

1900 ,n-n-un-,-urn *6 -- 2StdDev+1-9--X 2StdDev-

1850] -- 3StdDev+

1800 : ; X. " .x × ,' -e--3StdDev-

1750

1700.

1650.

1600

.111, -10 pl? ..IN j1p ..11% ýý If% Xk .-:1 .15 NUZ 5-' cb- f6' 5- W 54- lb- lb- cb- N' !N*-

fc, q\q NAA. q\.:*bN 414N -A-IN lop

44 44" V 1,

G-10-1 Printed: 3/4/98 2:41:53 PM

Page 118: REPLY TO ATTENTION OF MCHB-TS-OIP (40) 01 1998 · Mullikin, Research Health Physics Technician, U.S. Army Center for Health Promotion and Preventive Medicine (USACHPPM) with Mr. Richard

Indust Radn Surv No. 2.H-4939-R-97, Facility CL--out and-Termination Surv, Camp -Kilmer, NJ, .1 Jul - 20 Dec 97

Instrument Daily Control Chart

...

InstrumentQCID:

Meter Serial #: 120615Meter Make I Model #: LUDLUM 2350QCDateTime: 11/29/97 2:01:43 PMSurveyor: Lorus Miller

8

Probe Serial M: 133843GProbe Make I Model # 44-2

Check Source IsotopeSerial NumberActivity

30

Cs-1372031-95

1978020 DPMBackground:

Mean:StdDev:2StdDev:3StdDev:

5.5 CPM

# Data Points547.015.631.146.7

515.9500.3

578.1593.7

Count Time:

Instrument Efficiency:

60

-100.00%

Instrument QC Data:1129197 12:49:35 PM 530 MidDay,11/29/97 6:22:09 AM 549 AM11129/97 6:36:02 PM 549 PM

12/1197 6:47:26 AM 561 AM12/1197 1:22:33 PM 541 MidDay12/1/97 6:47:37 PM 564 PM1212/97 7:07:42 AM 523 AM

1212/97 12:26:52 PM 570 MidDay12122/97 6:05:56 PM 545 PM

620.

600.

580.

560.

540.

520.

500

480.

Control Chart

---- Net Reading---- Mean-fA-2StdDev+--- 2StdDev-

* 3StdDev+-.- 3StdDev-

--------.3

S A' -' '-S ~S AS A* A

460 J

44011129/97 11/29/97 11129/97 12/119712A9 6:22 18:36 6:47

12/1197 121119713"22 18:47

12/2.97 1212197 12122/977:07 12:26 18-05

Zh I: Vi 11330 8661

it 013 2G-11-1 P JY419 i3••8 2:42:24 PM


Recommended