Report No.: 8A092606F Page 1 of 25

Interocean EMC Technology Corp. FCC Test Report

Test Report

FCC Part 15 Subpart B (Verification)

for

Electromagnetic Interference

of

Product: Industrial rackmount switch

Trade Name: MOXA

Model Number: IKS-6726-X-X1-X2-X3 X= F (stands for cable direction) X1= 24 or 48 or HV (stands for 1st power module type) X2= 24 or 48 or HV or Bland (Stands for 2nd power module type)X3= T (stands for wide temperature)

Prepared for

Prepared by

Interocean EMC Technology Corp. 244 No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang,

Taipei County, Taiwan 244, R.O.C. TEL.: +886 2 2600 6861 FAX.: +886 2 2600 6859

Designation Number: TW1020

Remark: The test report consists of 25 pages in total. It shall not be reproduced except in full,

without the written approval of IETC. This document may be altered or revised by IETC only, and shall be noted in the revision section of the document. The test results in the report only to the tested sample.

MOXA Inc.

Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C.

TEL: +886 2 8919 1230

FAX: +886 2 8919 1231

Page 3: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 2 of 25

Interocean EMC Technology Corp. FCC Test Report

Table of Contents

1 General Information 4 1.1 Description of Equipment Under Test 4 1.2 Details of Tested Supporting System 5 1.3 Test Facility 6 1.4 Measurement Uncertainty 7 1.5 Measured Mode 8 1.6 Configuration of EUT Setup 8 1.7 Test Step of EUT 8 2 Power Line Conducted Emission Measurement 9 2.1 Instrument 9 2.2 Block Diagram of Test Configuration 9 2.3 Conducted Limit 10 2.4 Instrument configuration 10 2.5 Configuration of Measurement 10 2.6 Test Result 10 3 Radiated Emission Measurement (below 1GHz) 15 3.1 Instrument 15 3.2 Block Diagram of Test Configuration 15 3.3 Radiated Limit 16 3.4 Instrument configuration 16 3.5 Configuration of Measurement 16 3.6 Test Result 16 4 Radiated Emission Measurement (above 1GHz) 21 5 Photographs of Measurement 22 5.1 Power Line Conducted Test 22 5.2 Radiated Emission Measurement (below 1GHz) 23 6 Photographs of EUT 24

Page 4: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC
Page 5: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 4 of 25

Interocean EMC Technology Corp. FCC Test Report

1 General Information 1.1 Description of Equipment Under Test

Product : Industrial rackmount switch Model Number : IKS-6726-X-X1-X2-X3

X= F (stands for cable direction) X1= 24 or 48 or HV (stands for 1st power module type) X2= 24 or 48 or HV or Bland (Stands for 2nd power module type) X3= T (stands for wide temperature)

Applicant : MOXA Inc. Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C.

Manufacturer : MOXA Inc. Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C.

Date of Receipt of Sample : Sep. 26, 2008

Date of Test : Sep. 26 ~ Oct. 23, 2008

Power Supply : Input: 100~240VAC, 50~60Hz, 1.5A Input: 24VDC; 48VDC; 250VDC Power cord: Non-shielded Detachable, 1.8 m w/o core

Product Information : Interface Port: 1. Console Port *1 2. LAN Port *26 3. Fiber Port *2 4. Power Port *1

Additional Description : 1.) The EUT is “Industrial rackmount switch”.

2.) The model number difference please see detail as follows:

Model Number: IKS-6726-X-X1-X2-X3

X= F (stands for cable direction)

X1= 24 or 48 or HV (stands for 1st power module type)

X2= 24 or 48 or HV or Bland (stands for 2nd power module type)

X3= T (stands for wide temperature)

3.) The Model Number “IKS-6726-F-48-HV” is representative

selected in the test and included in this report.

Page 6: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 5 of 25

Interocean EMC Technology Corp. FCC Test Report

1.2 Details of Tested Supporting System

1.2.1 Link NoteBook Model Number : 2655-GT1

Serial Number : 78-LRZR4

EMC Approved : FCC DoC, CE, VCCI, BSMI 3902I050

Manufacturer : IBM Adapter : IBM AA21070, BSMI 3892A299

Input: 100-240VAC, 1.2~0.5A, 50/60Hz Non-shielded, Detachable, 1.5m Output: 16VDC, 4.5A Non-shielded, Un-detachable, 1.8m

1.2.2 Data Cable

LAN Cable *13 : Shielded, Detachable, 1m, w/o core LAN Cable *1 : Non-shielded, Detachable, 3m, w/o core Console Cable *1 : Non-shielded, Detachable, 1.2m, w/o core

Page 7: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 6 of 25

Interocean EMC Technology Corp. FCC Test Report

1.3 Test Facility

Site Description : OATS 1 Conduction 1

Name of Firm : Interocean EMC Technology Corp.

Company web : http://www.ietc.com.tw

Site 1, 2 Location : No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei County, Taiwan, R.O.C.

Site 3, 4 Location : No. 12, Ruei-Shu Valley, Ruei-Ping Tsun, Lin-Kou Hsiang, Taipei County, Taiwan, R.O.C.

Site Filing : Federal Communication Commissions – USA Registration No.: 96399 (OATS 1 & 2) Registration No.: 518958 (OATS 3 & 4)

Voluntary Control Council for Interference by Information Technology Equipment (VCCI) – Japan Registration No. (Conducted Room): C-1094 Registration No. (Conducted Room): T-271 Registration No. (OATS 1): R-1040 Registration No. (OATS 2): R-1041

Industry Canada (IC) Submission: 113543

Japan Electrical Safety & Environment Technology Laboratories (JET)Registration No.: 04S03-01

Site Accreditation : Bureau of Standards and Metrology and Inspection (BSMI) –Taiwan, R.O.C. Accreditation No.: SL2-IN-E-0026 for CNS13438 / CISPR22 SL2-R1-E-0026 for CNS13439 / CISPR13 SL2-R2-E-0026 for CNS13439 / CISPR13 SL2-A1-E-0026 for CNS13783-1 / CISPR14-1

Taiwan Accreditation Foundation (TAF) Accrditation No.: 1113

TüV NORD Certificate No: TNTW0801R

Page 8: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 7 of 25

Interocean EMC Technology Corp. FCC Test Report

1.4 Measurement Uncertainty

No. Item Value

1 Power Line Conducted Emission (Conduction 1) 2.40 dB

2 Power Line Conducted Emission (Conduction 2) 2.40 dB

3 Disturbance Power Emission (Conduction 2) 3.10 dB

4 Click disturbances Emission (Conduction 2) 2.40 dB

5 Radiated Electromagnetic disturbance (Loop Antenna) 4.80 dB

6 Radiated Emission Test (OATS 1) 3.14 dB

7 Radiated Emission Test (OATS 2) 3.14 dB

8 Radiated Emission Test (OATS 3) 3.14 dB

9 Radiated Emission Test (OATS 4) 3.14 dB

10 Radiated Emission Test (1GHz~18GHz) 3.20 dB

11 Radiated Emission Test (18GHz~40GHz) 3.40 dB

Page 9: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 8 of 25

Interocean EMC Technology Corp. FCC Test Report

1.5 Measured Mode

1.5.1 The test modes for preliminary test are as following: Mode 1: LAN Mode (120VAC) Mode 2: LAN Mode (250VDC) Mode 3: LAN Mode (48VDC) Mode 4: LAN Mode (24VDC)

1.5.2 After preliminary test, EUT was selected the worse case for the final testing. The test modes are: For Conduction: Mode 1 & 3 For Radiation: Mode 1 & 3

1.6 Configuration of EUT Setup

1.7 Test Step of EUT

1.7.1 Setup the EUT and peripheral as above. 1.7.2 Execute power on of EUT and link with peripheral NoteBook. 1.7.3 Executed the test.

Link NoteBook

LAN Cable*12

AC or DC IN Console Cable Floating

EUT LAN Cable

LAN Cable Floating

Page 10: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 9 of 25

Interocean EMC Technology Corp. FCC Test Report

2 Power Line Conducted Emission Measurement 2.1 Instrument

Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESCS 30 830245/027 2009/08/19

Pulse Limiter Rohde & Schwarz ESH3-Z2 843602/02 2009/09/08

RF Cable HARBOUR RG400 CBL32 2009/03/18

L.I.S.N. SCHAFFNER MN2050D 1596 2009/06/15

L.I.S.N. Rohde & Schwarz ESH3-Z5 100176 2009/02/17

Note: The above equipments are within the valid calibration period.

2.2 Block Diagram of Test Configuration

H.C.P.

V.C.P.

EUT

LISN

40cm

80cm

Test Receiver Pulse Limiter

Page 11: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 10 of 25

Interocean EMC Technology Corp. FCC Test Report

2.3 Conducted Limit

FCC Part 15 Class A (dBµV) Class B (dBµV) Frequency

(MHz) Q.P. (Quasi-Peak) A.V. (Average) Q.P. (Quasi-Peak) A.V. (Average) 0.15 ~ 0.50 79 66 66 to 56 56 to 46 0.50 ~ 5.0 73 60 56 46 5.0 ~ 30 73 60 60 50

2.4 Instrument configuration

2.4.1 Set the EMI test receiver frequency range from 150 kHz to 30 MHz. 2.4.2 Set the EMI test receiver bandwidth at 9kHz. 2.4.3 Set the EMI test receiver detector as Quasi-Peak (Q.P.) and Average (AV).

2.5 Configuration of Measurement

2.5.1 The EUT was placed on a non-conductive table whose total height equaled 80cm and vertical conducting plane located 40cm to the rear of the EUT.

2.5.2 The EUT was connected to the main power through Line Impedance Stabilization Networks (LISN). This setup provided a 50ohm/50µH coupling impedance for the measuring equipment. The auxiliary equipment was also connected to the main power through a LISN that provided a 50ohm/50µH coupling impedance with 50ohm termination. (Refer to the block diagram of the test setup and photographs.)

2.5.3 The conducted disturbance was measured between the phase lead and the reference ground, and between the neutral lead and reference ground. The initial testing identified the frequency that has the highest disturbance relative to the limit while operating the EUT in typical modes of operation and cable positions in a test setup representative of typical system configuration.

2.5.4 The identification of the frequency of highest disturbance with respect to the limit was found by investigating disturbances at a number of significant frequencies. The probable frequency of maximum disturbance had been found and that the associated cable and EUT configuration and mode of operation had been identified.

2.6 Test Result

PASS. The final test data is shown on as following pages.

Page 12: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 11 of 25

Interocean EMC Technology Corp. FCC Test Report

Power Line Conducted Test Data

EUT: Industrial rackmount switch

CLIENT: MOXA Inc.

MODEL: IKS-6726-F-48-HV

RATING: 120V/60Hz

Temperature: 25.0 ℃

Humidity: 55 %

POLARITY: Line

DISTANCE:

Serial No.:

FILE/DATA#: MOXA Inc.emi/145

OPERATOR: Nigel

TEST SITE: Conduction1

Frequency Factor Meter Reading (dBµV) Emission Level (dBµV) Limits (dBµV) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.158 0.13 41.66 31.81 41.79 31.94 79.00 66.00 -37.21 -34.06

2.201 0.19 40.20 40.00 40.39 40.19 73.00 60.00 -32.61 -19.81

2.412 0.21 40.50 40.44 40.71 40.65 73.00 60.00 -32.29 -19.35

2.568 0.22 37.40 37.10 37.62 37.32 73.00 60.00 -35.38 -22.68

2.779 0.23 35.03 34.84 35.26 35.07 73.00 60.00 -37.74 -24.93

5.295 0.34 36.79 36.61 37.13 36.95 73.00 60.00 -35.87 -23.05

Remark: 1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss.

Test Mode: Mode 1: LAN Mode (120VAC)

Page 13: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 12 of 25

Interocean EMC Technology Corp. FCC Test Report

Power Line Conducted Test Data

EUT: Industrial rackmount switch

CLIENT: MOXA Inc.

MODEL: IKS-6726-F-48-HV

RATING: 120V/60Hz

Temperature: 25.0 ℃

Humidity: 55 %

POLARITY: Neutral

DISTANCE:

Serial No.:

FILE/DATA#: MOXA Inc.emi/146

OPERATOR: Nigel

TEST SITE: Conduction1

Frequency Factor Meter Reading (dBµV) Emission Level (dBµV) Limits (dBµV) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.158 0.13 41.31 31.41 41.44 31.54 79.00 66.00 -37.56 -34.46

1.837 0.17 32.21 31.04 32.38 31.21 73.00 60.00 -40.62 -28.79

2.255 0.18 37.90 37.30 38.08 37.48 73.00 60.00 -34.92 -22.52

2.412 0.19 37.90 37.80 38.09 37.99 73.00 60.00 -34.91 -22.01

5.509 0.25 36.21 35.25 36.46 35.50 73.00 60.00 -36.54 -24.50

23.127 0.92 28.70 26.08 29.62 27.00 73.00 60.00 -43.38 -33.00

Remark: 1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss.

Test Mode: Mode 1: LAN Mode (120VAC)

Page 14: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 13 of 25

Interocean EMC Technology Corp. FCC Test Report

Power Line Conducted Test Data

EUT: Industrial rackmount switch

CLIENT: MOXA Inc.

MODEL: IKS-6726-F-48-HV

RATING: DC 48V

Temperature: 26.0 ℃

Humidity: 60 %

POLARITY: Line

DISTANCE:

Serial No.:

FILE/DATA#: MOXA Inc.emi/139

OPERATOR: Terry

TEST SITE: Conduction1

Frequency Factor Meter Reading (dBµV) Emission Level (dBµV) Limits (dBµV) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.240 0.15 53.70 53.60 53.85 53.75 79.00 66.00 -25.15 -12.25

0.482 0.15 40.80 40.70 40.95 40.85 79.00 66.00 -38.05 -25.15

4.330 0.32 41.10 41.00 41.42 41.32 73.00 60.00 -31.58 -18.68

4.810 0.33 43.60 43.38 43.93 43.71 73.00 60.00 -29.07 -16.29

13.420 0.68 38.65 35.62 39.33 36.30 73.00 60.00 -33.67 -23.70

16.228 0.79 40.20 37.74 40.99 38.53 73.00 60.00 -32.01 -21.47

Remark: 1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss.

Test Mode: Mode 3: LAN Mode (48VDC)

Page 15: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 14 of 25

Interocean EMC Technology Corp. FCC Test Report

Power Line Conducted Test Data

EUT: Industrial rackmount switch

CLIENT: MOXA Inc.

MODEL: IKS-6726-F-48-HV

RATING: DC 48V

Temperature: 26.0 ℃

Humidity: 60 %

POLARITY: Neutral

DISTANCE:

Serial No.:

FILE/DATA#: MOXA Inc.emi/140

OPERATOR: Terry

TEST SITE: Conduction1

Frequency Factor Meter Reading (dBµV) Emission Level (dBµV) Limits (dBµV) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.240 0.16 51.20 51.13 51.36 51.29 79.00 66.00 -27.64 -14.71

0.720 0.17 37.90 37.80 38.07 37.97 73.00 60.00 -34.93 -22.03

4.326 0.31 40.60 40.56 40.91 40.87 73.00 60.00 -32.09 -19.13

4.806 0.33 43.80 43.70 44.13 44.03 73.00 60.00 -28.87 -15.97

13.420 0.76 38.77 36.10 39.53 36.86 73.00 60.00 -33.47 -23.14

16.228 0.88 40.77 38.30 41.65 39.18 73.00 60.00 -31.35 -20.82

Remark: 1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss.

Test Mode: Mode 3: LAN Mode (48VDC)

Page 16: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 15 of 25

Interocean EMC Technology Corp. FCC Test Report

3 Radiated Emission Measurement (below 1GHz) 3.1 Instrument

Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESCS30 100135 2009/09/10

Bilog Antenna Schaffner CBL6111c 2804 2009/02/24

Pre-Amplifier Agilent 8447D 1937A01903 2008/12/09

RF Cable Ultra Link CBL17 CBL17 2009/04/14

Note: The above equipments are within the valid calibration period.

3.2 Block Diagram of Test Configuration

Configuration of Testing Setup

10 m or 3 m

1~ 4 m

Test Receiver

80 cm

EUT

Page 17: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 16 of 25

Interocean EMC Technology Corp. FCC Test Report

3.3 Radiated Limit

FCC Part 15 Class A (10m) Class B (3m)

Frequency (MHz)

Field Strength (μV)

Quasi-Peak dB(μV/m)

Field Strength (μV)

Quasi-Peak dB(μV /m)

30 ~ 88 90 39.08 100 40.00 88 ~ 216 150 43.52 150 43.52

216 ~ 960 210 46.44 200 46.02 960 above 300 49.54 500 53.98

CISPR 22 Class A Class B

Frequency (MHz) Quasi-Peak dB(μV /m)

Quasi-Peak dB(μV /m)

30 ~ 230 40.0 30.0

230 ~ 1000 47.0 37.0 ** According to 47 CFR FCC Part 15 § 15.109(g)

3.4 Instrument configuration

3.4.1 Set the EMI test receiver frequency range from 30 MHz to 1000 MHz. 3.4.2 Set the EMI test receiver bandwidth at 120 kHz. 3.4.3 Set the EMI test receiver detector as Quasi-Peak (Q.P.).

3.5 Configuration of Measurement

3.5.1 The EUT was placed on a non-conductive table whose total height equaled 80cm. The turntable can rotate 360 degree to determine the position of the maximum emission level.

3.5.2 The EUT was set 10 meters away from the receiving antenna that was mounted on a non-conductive mast. The antenna can move up and down between 1 to 4 meters to find out the maximum emission level.

3.5.3 The initial testing identified the frequency that has the highest disturbance relative to the limit while operating the EUT in typical modes of operation and cable positions in a test setup representative of typical system configuration.

3.5.4 The identification of the frequency of highest emission with respect to the limit was found by investigating emissions at a number of significant frequencies. The probable frequency of maximum emission had been found and that the associated cable and EUT configuration and mode of operation had been identified.

3.6 Test Result

PASS. The final test data is shown on as following pages.

Page 18: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 17 of 25

Interocean EMC Technology Corp. FCC Test Report

Radiated Emission Measurement Data

EUT: Industrial rackmount switch

CLIENT: MOXA Inc.

MODEL: IKS-6726-F-48-HV

RATING: 120V/60Hz

Temperature: 24.0 ℃

Humidity: 56 %

POLARITY: Horizontal

DISTANCE: 10 m

Serial No.:

FILE/DATA#: MOXA Inc.emi/144

OPERATOR: IVAN

TEST SITE: OATS1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBµV) (dBµV/m) (dBµV/m) (dB)

250.000 ** -12.85 46.80 33.95 47.00 -13.05

375.000 ** -8.92 48.10 39.18 47.00 -7.82

500.030 ** -5.80 39.80 34.00 47.00 -13.00

585.970 ** -3.26 42.30 39.04 47.00 -7.96

609.410 ** -2.17 45.50 43.33 47.00 -3.67

625.040 ** -1.08 41.50 40.42 47.00 -6.58

710.980 ** 0.63 36.80 37.43 47.00 -9.57

791.990 ** 1.35 42.30 43.65 47.00 -3.35

923.990 ** 3.72 42.60 46.32 47.00 -0.68

Remark: 1. “ * ” Mark means readings are Peak Values. 2. “ ** “ Mark means readings are Quasi-Peak values. 3. Factor = Antenna Factor + Cable Loss – Pre-amplifier.

Test Mode: Mode 1: LAN Mode (120VAC)

Page 19: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 18 of 25

Interocean EMC Technology Corp. FCC Test Report

Radiated Emission Measurement Data

EUT: Industrial rackmount switch

CLIENT: MOXA Inc.

MODEL: IKS-6726-F-48-HV

RATING: 120V/60Hz

Temperature: 24.0 ℃

Humidity: 56 %

POLARITY: Vertical

DISTANCE: 10 m

Serial No.:

FILE/DATA#: MOXA Inc.emi/143

OPERATOR: IVAN

TEST SITE: OATS1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBµV) (dBµV/m) (dBµV/m) (dB)

250.010 ** -12.73 46.80 34.07 47.00 -12.93

375.010 ** -8.74 46.80 38.06 47.00 -8.94

500.030 ** -5.35 38.60 33.25 47.00 -13.75

609.410 ** -2.36 40.10 37.74 47.00 -9.26

625.040 ** -1.27 37.90 36.63 47.00 -10.37

791.990 ** 1.30 35.70 37.00 47.00 -10.00

923.990 ** 3.76 35.70 39.46 47.00 -7.54

Remark: 1. “ * ” Mark means readings are Peak Values. 2. “ ** “ Mark means readings are Quasi-Peak values. 3. Factor = Antenna Factor + Cable Loss – Pre-amplifier.

Test Mode: Mode 1: LAN Mode (120VAC)

Page 20: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 19 of 25

Interocean EMC Technology Corp. FCC Test Report

Radiated Emission Measurement Data EUT: Industrial rackmount switch

CLIENT: MOXA Inc.

MODEL: IKS-6726-F-48-HV

RATING: DC 48V

Temperature: 24.0 ℃

Humidity: 56 %

POLARITY: Horizontal

DISTANCE: 10 m

Serial No.:

FILE/DATA#: MOXA Inc.emi/150

OPERATOR: IVAN

TEST SITE: OATS1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBµV) (dBµV/m) (dBµV/m) (dB)

250.000 ** -12.85 47.37 34.52 47.00 -12.48

375.000 ** -8.92 47.56 38.64 47.00 -8.36

500.030 ** -5.80 41.77 35.97 47.00 -11.03

585.970 ** -3.26 43.38 40.12 47.00 -6.88

609.410 ** -2.17 45.82 43.65 47.00 -3.35

625.040 ** -1.08 41.71 40.63 47.00 -6.37

710.980 ** 0.63 36.57 37.20 47.00 -9.80

791.990 ** 1.35 41.79 43.14 47.00 -3.86

923.990 ** 3.72 42.41 46.13 47.00 -0.87

Remark: 1. “ * ” Mark means readings are Peak Values. 2. “ ** “ Mark means readings are Quasi-Peak values. 3. Factor = Antenna Factor + Cable Loss – Pre-amplifier.

Test Mode: Mode 3: LAN Mode (48VDC)

Page 21: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 20 of 25

Interocean EMC Technology Corp. FCC Test Report

Radiated Emission Measurement Data

EUT: Industrial rackmount switch

CLIENT: MOXA Inc.

MODEL: IKS-6726-F-48-HV

RATING: DC 48V

Temperature: 24.0 ℃

Humidity: 56 %

POLARITY: Vertical

DISTANCE: 10 m

Serial No.:

FILE/DATA#: MOXA Inc.emi/151

OPERATOR: IVAN

TEST SITE: OATS1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBµV) (dBµV/m) (dBµV/m) (dB)

250.010 ** -12.73 48.15 35.42 47.00 -11.58

375.010 ** -8.74 47.84 39.10 47.00 -7.90

500.030 ** -5.35 40.97 35.62 47.00 -11.38

609.410 ** -2.36 40.67 38.31 47.00 -8.69

625.040 ** -1.27 38.21 36.94 47.00 -10.06

791.990 ** 1.30 35.80 37.10 47.00 -9.90

923.990 ** 3.76 36.44 40.20 47.00 -6.80

Remark: 1. “ * ” Mark means readings are Peak Values. 2. “ ** “ Mark means readings are Quasi-Peak values. 3. Factor = Antenna Factor + Cable Loss – Pre-amplifier.

Test Mode: Mode 3: LAN Mode (48VDC)

Page 22: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 21 of 25

Interocean EMC Technology Corp. FCC Test Report

4 Radiated Emission Measurement (above 1GHz) If the highest frequency of the internal sources of the EUT is less than 108MHz, the measurement shall only be made up to 1 GHz.

Page 23: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 22 of 25

Interocean EMC Technology Corp. FCC Test Report

5 Photographs of Measurement 5.1 Power Line Conducted Test

Front View

Rear View

Page 24: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 23 of 25

Interocean EMC Technology Corp. FCC Test Report

5.2 Radiated Emission Measurement (below 1GHz)

Front View

Rear View

Page 25: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 24 of 25

Interocean EMC Technology Corp. FCC Test Report

6 Photographs of EUT

Front View of EUT

Rear View of EUT

Page 26: Report No.: 8A092606F Page 1 of 25support.elmark.com.pl/.../IKS-6726/certyfikaty/_FCC.pdf · 2009-07-30 · Report No.: 8A092606F Page 4 of 25 Interocean EMC Technology Corp. FCC

Report No.: 8A092606F Page 25 of 25

Interocean EMC Technology Corp. FCC Test Report

I/O Port-1

I/O Port-2