RENATRON ® ll 100 RENATRONPA 100 Reprocessing Systems Change...and continuity Reprocessing Systems. Sterilants. Disinfectants. Concentrates. The Updated RENATRON Series Reprocessing Systems are the foundations for the most complete reprocessing solution for your clinic. Other components of this system include: See DFU for more detailed specifications Reprocessing Systems RENATRON ® Series Specifications Change…and continuity Feed Line Flow 0.46 gallons/minute (1.75 liters/minute) at average pressure of 20-55 psig Peak Flow 1.6 gallons/minute (6 liters/minute). This peak flow is for 15-35 seconds in duration. Quality Must meet ANSI/AAMI RD-62 and RD-47 Temperature 59ºF-75ºF (15ºC-24ºC) Static Pressure Should not be in excess of 55 psig (379 K Pa, 3.79 Bars) Drain Minimum flow requirement is 1.6 gallons/minute (6 liters/minute) per reprocessing station. Room Temperature 41ºF-104ºF (5ºC-40ºC) Room Humidity Maximum relative humidity of 80% at 87.8ºF (31ºC) Width Depth Height Weight (Approximately) (Approximately) (Approximately) (Approximately) RENATRON II , PA Series 14.5” (41 cm) 12.3” (31 cm) 16” (33 cm) 50 lbs (23 kg) Interface Module 12” (30.5 cm) 11” (28 cm) 3.5” (8.9 cm) 6 lbs (2.7 kg) Drip Tray (Single)* 15.25” (39 cm) 28” (71 cm) 3.5” (9 cm) 3 lbs (1.36 cm) Drip Tray (Dual)* 33.25” (85 cm) 28” (71 cm) 3.5” (9 cm) 6 lbs (2.73 cm) Computer 7.3” (18 cm) 17.3” (44 cm) 16.3” (41 cm) 27.2 lbs (12.34kg) Monitor-CTR 14.2” (36 cm) 15.6” (39 cm) 14.8” (38 cm) 28 lbs (12.5 kg) Monitor-LCD 13.4” (34 cm) 6” (15 cm) 13.4” (34 cm) 7 lbs (3.2 kg) Report Printer (Approximately) 17.7” (50 cm) 14.6” (37 cm) 5.7” (15 cm) 11.7 lbs (5.3 kg) Label Printer (Approximately) 7.9” (20 cm) 9.75” (24.8 cm) 6.8” (17.3 cm) 3.2 lbs (1.5 kg) Water Requirements for a Single RENATRON Reprocessing Station Size and Weight Environmental Limits RENATRON Interface Computer Monitor Report Label Station Module Printer Printer Voltage 100, 220, 230, 115/230 VAC, 100-120 100-120/ 100-240 100-240 240 VAC 50/60 Hz VAC, 100-240 VAC VAC VAC, 50/60 Hz Single Phase 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Single phase Consumption 460 VA 20 VA 230 Watt 30/100 Watt 30 Watt 39.1 Watt Max Max Max Max Max Max Electrical *Counter depth needs to account for gauge blocks. Measurements DO NOT take into account space needed for gauge blocks (between 3” to 6”). Contact your MEDIVATORS representative for additional information. • RENALIN ® 100 Cold Sterilant • RENALOG ® RM Software/Data Management • RENALIN ® Indicator and Residual Test Strips • ON DEMAND ® Autodilution System About MEDIVATORS MEDIVATORS has been providing WORKING SOLUTIONS to the hemodialysis community since 1972. MEDIVATORS dialyzer reprocessing systems, sterilants, disinfectants and dialysate concentrates have been used in thousands of clinics and tens of millions of treatments Today, MEDIVATORS continues to provide dialysis clinics with the highest quality products and services to ensure that clinics have the WORKING SOLUTIONS necessary for optimal patient care. RENATRON ll 100 RENATRON PA 100 Int’l Version (230V) Model RS Number 78399-446 RENATRON ll 100 RS-8335 78399-448 RENATRON PA 100 RS-8315 Model Availability For More Information Contact MEDIVATORS at www.medivators.com/renal RENATRON ® , RENALIN ® , RENALOG ® and ON DEMAND ® are registered trademarks of Medivators Inc. FORMULA 409 ® is a registered trademark of The Clorox Company © 2015 MEDIVATORS Inc. P/N 50098-427C
Transcript
Page 1: Reprocessing Systems · 2018. 8. 2. · RENATRON® ll 100 RENATRONPA 100 Reprocessing Systems Change...and continuity Reprocessing Systems.Sterilants. Disinfectants. Concentrates.

RENATRON® ll 100RENATRON PA 100 Reprocessing SystemsChange...and continuity

R e p r o c e s s i n g S y s t e m s . S t e r i l a n t s . D i s i n f e c t a n t s . C o n c e n t r a t e s .

The Updated RENATRON Series Reprocessing Systems are thefoundations for the most completereprocessing solution for your clinic. Other components of this system include:

See DFU for more detailed specifications

R e p r o c e s s i n g S y s t e m sRENATRON® Series Specifications Change…and continuity

Feed Line Flow 0.46 gallons/minute (1.75 liters/minute) at average pressure of 20-55 psig

Peak Flow 1.6 gallons/minute (6 liters/minute). This peak flow is for 15-35 seconds in duration.

Quality Must meet ANSI/AAMI RD-62 and RD-47

Temperature 59ºF-75ºF (15ºC-24ºC)

Static Pressure Should not be in excess of 55 psig (379 K Pa, 3.79 Bars)

Drain Minimum flow requirement is 1.6 gallons/minute (6 liters/minute) per reprocessing station.

Room Temperature 41ºF-104ºF (5ºC-40ºC)

Room Humidity Maximum relative humidity of 80% at 87.8ºF (31ºC)

Width Depth Height Weight (Approximately) (Approximately) (Approximately) (Approximately)

RENATRON II , PA Series 14.5” (41 cm) 12.3” (31 cm) 16” (33 cm) 50 lbs (23 kg)

Interface Module 12” (30.5 cm) 11” (28 cm) 3.5” (8.9 cm) 6 lbs (2.7 kg)

Drip Tray (Single)* 15.25” (39 cm) 28” (71 cm) 3.5” (9 cm) 3 lbs (1.36 cm)

Drip Tray (Dual)* 33.25” (85 cm) 28” (71 cm) 3.5” (9 cm) 6 lbs (2.73 cm)

Computer 7.3” (18 cm) 17.3” (44 cm) 16.3” (41 cm) 27.2 lbs (12.34kg)

Monitor-CTR 14.2” (36 cm) 15.6” (39 cm) 14.8” (38 cm) 28 lbs (12.5 kg)

Monitor-LCD 13.4” (34 cm) 6” (15 cm) 13.4” (34 cm) 7 lbs (3.2 kg)

Report Printer (Approximately) 17.7” (50 cm) 14.6” (37 cm) 5.7” (15 cm) 11.7 lbs (5.3 kg)

Label Printer (Approximately) 7.9” (20 cm) 9.75” (24.8 cm) 6.8” (17.3 cm) 3.2 lbs (1.5 kg)

Water Requirements for a Single RENATRON Reprocessing Station

Size and Weight

Environmental Limits

RENATRON Interface Computer Monitor Report Label Station Module Printer Printer Voltage 100, 220, 230, 115/230 VAC, 100-120 100-120/ 100-240 100-240 240 VAC 50/60 Hz VAC, 100-240 VAC VAC VAC, 50/60 Hz Single Phase 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Single phase Consumption 460 VA 20 VA 230 Watt 30/100 Watt 30 Watt 39.1 Watt Max Max Max Max Max Max

Electrical

*Counter depth needs to account for gauge blocks. Measurements DO NOT take into account space needed for gauge blocks(between 3” to 6”). Contact your MEDIVATORS representative for additional information.

• RENALIN® 100 Cold Sterilant• RENALOG® RM

Software/Data Management• RENALIN® Indicator and

Residual Test Strips• ON DEMAND® Autodilution System

About MEDIVATORS

MEDIVATORS has been providingWORKING SOLUTIONS to the hemodialysis community since 1972. MEDIVATORS dialyzer reprocessingsystems, sterilants, disinfectants and dialysate concentrates have been used in thousands of clinics and tens of millions of treatments

Today, MEDIVATORS continues to provide dialysis clinics with thehighest quality products and servicesto ensure that clinics have the WORKING SOLUTIONS necessary for optimal patient care.

RENATRON ll 100RENATRON PA 100

Int’l Version (230V) Model RS Number

78399-446 RENATRON ll 100 RS-8335

78399-448 RENATRON PA 100 RS-8315

Model Availability

For More Information Contact MEDIVATORSat www.medivators.com/renal

RENATRON®, RENALIN®, RENALOG® and ON DEMAND®

are registered trademarks of Medivators Inc.FORMULA 409® is a registered trademark of The Clorox Company

© 2015 MEDIVATORS Inc. P/N 50098-427C

Page 2: Reprocessing Systems · 2018. 8. 2. · RENATRON® ll 100 RENATRONPA 100 Reprocessing Systems Change...and continuity Reprocessing Systems.Sterilants. Disinfectants. Concentrates.

THERE IS A PLACE FOR CHANGE… AND A PLACE FORCONTINUITYThe Updated RENATRON® II and PA SERIESReprocessing System brings all of the best features of the original but with critical enhancements determined by our customers.

History of Success

• RENATRON Reprocessing SystemIntroduced in1982

• Over 25 years and tens of millions of dialyzers reprocessed

Automated Reprocessing Cycle

• 10 minute cycle flushes, cleans, tests and fills dialyzers

Header Integrity Test

• Diagnostic test to verify that the header is on securely with “O” ring in place

Failed Volume Test

• Limiting the number of retests to 2 to get moreaccurate measurements

Culture Sample Cycle

• Separate cycle for ease of taking water samples

Dedicated Clean/

Rinse Cycle

• Alternative and more aggressive FORMULA 409® cyclefor heavily deposited lines and machines

RENATRON® II 100 SeriesReprocessing System

On the InsideThe Gold Standard in Reprocessing On the Outside

Venous Line Clamp

• Prevent cross contamination

Color Coding

• Provide visual cues to dialyzer orientation

More Defined

Control Panel Areas

Complete Reprocessing System

• RENALIN® and RENALIN 100: Environmentally safe sterilants

• RENALOG® RM Software: Most advanced dialyzer reprocessing data management system

Expandability

• Up to 12 RENATRON II 100 Series systems can be connected together via RENALOG RM data management software