Date post: | 28-Mar-2016 |
Category: |
Documents |
Upload: | portal-vrancea-comro |
View: | 217 times |
Download: | 1 times |
Submerged Internal Trip Connection
specially engineered design with platform switching maintains crestal bone.Restoration of molar sites can be achieved with Rescue implants, despite minimal vertical height and inferior osseos tissue sites. Molar extraction sockets can be immediately restored with Rescue fixtures
Design: The 0.8 degree pitched thread provides maximum contact for effective os-seointegration. Because of the buttress thread design, it can withstand strong mas-ticatory forces. The four cutting edges and guided bottom ensure maximum initial stability.
Surface: Our Super RBM Surface Treatment produces a favorable surface topogra-phy that has been proven through extensive systematic testing. MegaGen‘s Super RBM Surface shortens loading time and provides favorable results in any bone quality.
Feature: Internal Trip Connection - MegaGen‘s Trip anti-rotation structure will not de-
11° Internal Connection Wall, which is a proven concept of Morse Taper & Conical Seal, effectively allows for extremely high occlusal and lateral forces. Initial stability upon placement is provided.
Surgery: -sisting of a Trephine drill and a Pilot drill, (using the drill stop in the trephine drill). The
solution.
Prosthetics: The Rescue Internal system provides various Internal Trip Connection Abutments (UCLA Gold, EZ Post, Milling abutment, Solid abutment system) that have
-meters. This conveniently provides aesthetic and functional prosthetic options.
Packaging: Internal Fixture with Cover Screw
Super Wide & Short - The Most Effective Implant System for Molar Reconstruction
Rescue® Internal
Trip Indicating Grooves
PlatformDiameter
M2.5mmFemale Screw
Inner holeDiameter:
Ø 4.0Tripod Grip
D2
D1 D2 L(mm)
Ø6.0 Ø4.5 5.0
6.0
7.0
8.5
10.0
11.5
13.0
Ø6.5 Ø5.0
Ø7.0 Ø5.0
Ø7.5 Ø5.5
Ø8.0 Ø6.0
ThreadDiameter
Fixure LengthSuper RBM Surface
internal Angle 11°
D1
L
SEM(X1000)SEM(X1000)
Super - RBM S
urfa
ce
Contact gegevens MegaGen Benelux:
Telefoon: +31 (0)88 - 84 84 100Fax: +31 (0)88 - 84 84 109Email: [email protected]: www.megagenbenelux.nl
Postadres MegaGen Benelux bv: Postbus 6495000 AP TilburgNederland
Vestigingsadres MegaGen Benelux bv:Prof. Cobbenhagenlaan 995037 DB TilburgNederland
Bestelling(en) doorgeven per email: [email protected]
Vragen over onze producten en toebehoren:[email protected]
Ø6.0MTPR600I
Ø6.0MTPH600I
Ø6.5MTPR650I
Ø6.5MTPH650I
Ø7.0MTPR700I
Ø7.5MTPR750I
Ø8.0MTPR800I
Ø7.0MTPH700I
Ø7.5MTPH750I
Ø8.0MTPH800I
MarkingLength
13.0 mm11.5 mm10.0 mm8.5 mm7.0 mm
6.0 mm
5.0 mm
For 6.0 & 6.5 Diameter Fixturesv For 7.0 & 7.5 Diameter Fixturesv For 8.0 Diameter Fixture
4
Inner Dia Ø4.0Outer Dia Ø5.0
MRTB4010
Inner Dia Ø5.0Outer Dia Ø6.0
MRTB5010
Hand Piece Connectors
Ratchet Extensions
Inner Dia Ø6.0Outer Dia Ø7.0
MRTB6010
1
2
3
SG II Rescue Surgical Kit
MarkingLength
Ø5.4MRPD540
Ø5.9MRPD590
Ø6.4MRPD640
Ø6.9MRPD690
Ø7.4MRPD740
13.0 mm11.5 mm10.0 mm8.5 mm7.0 mm
6.0 mm
5.0 mm
RSWIR6005CRSWIR6006CRSWIR6007CRSWIR6008CRSWIR6010CRSWIR6011CRSWIR6013C
RSWIR6505CRSWIR6506CRSWIR6507CRSWIR6508CRSWIR6510CRSWIR6511CRSWIR6513C
RSWIR7005CRSWIR7006CRSWIR7007CRSWIR7008CRSWIR7010CRSWIR7011CRSWIR7013C
RSWIR7505CRSWIR7506CRSWIR7507CRSWIR7508CRSWIR7510CRSWIR7511CRSWIR7513C
RSWIR8005CRSWIR8006CRSWIR8007CRSWIR8008CRSWIR8010CRSWIR8011CRSWIR8013C
5.0 mm6.0 mm7.0 mm8.5 mm
10.0 mm11.5 mm13.0 mm
Ø6.0 Ø6.5 Ø7.0 Ø7.5 Ø8.0
MOW4 00 MRW040S
11
22
33
44
55
5555
MRHC100
MRIR100S
MRHC200
MRIR100L
Drill Extension Direction Indicator 1.2 Hand Driver Extension Plus
RatchetExtensions[Ext/Int]
Safety Trephine Stopper system
In order to create the osteotomy, follow drilling
For safe trephine drilling, rotate drill in counter clockwise direction until saw part of trephine bur engages crest of bone. Then proceed drilling in clockwise direction.
Step 1: Trephine Drilling with Stopper
10.0 mm8.0 mm6.0 mm4.0 mm2.0 m
6.0 7.0 8.5 10.0MRTBS06
MRTBS07MRTBS08
MRTBS10
MarkingLength
Use the mount-free handpiece connector to place the
the ratchet wrench. To easily verify trip direction
coronal portion of the implant.
STEP 4: Fixture Placement
MDE150 MDI5060
Ø5.0
Ø6.0
TCMHDL1200 orTCMHDS1200
1.2 Hex
MRE400S
5
In accordance with drilling sequence, extended the osteotomy using the pilot drill.
STEP 2: Pilot Drilling
In dense bone situations, pre-tapping may be
STEP 3: Tapping
Cover Screw
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Interface Diameter REF-Code
Ø4.0 mm ARSIC100
Healing Abutment
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Ø6.0 mm Ø8.0 mm Ø10.0 mm
2.0 mm ARSIH602 ARSIH802 ARSIH1002
3.0 mm ARSIH603 ARSIH803 ARSIH1003
4.0 mm ARSIH604 ARSIH804 ARSIH1004
5.0 mm ARSIH605 ARSIH805 ARSIH1005
Height
Impression Coping (Transfer Type)
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Impression coping with closed tray
10 mm Trip Type Guide Pin: Included ARIG300
1-Piece Trip Type
ARII100 ARII300T
1-Piece Trip Type
Impression Coping (Pick Up Type)
Impression coping with open Tray
15mm Guide Pin: Included ARIG100
Non-Trip Trip Type
ARII400T ARII200T
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Non-Trip Trip
Lab Analog
REF Code
Ø6.0 mm ARLA600
Component to duplicate the platform into a working model for prosthetics
Temporary Abutment
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Ø6.0 mm Non-Trip Trip
ARIT100T ARIT200T
Used in cases of path, esthetic and space adjustment
Screw included Non-Trip Trip
Cover Screw
Solid & Post Level Analog
Ø6.0 mm Ø7.0 mm Ø8.0 mm
ARIPL760 ARIPL860
solid abutment into working model to make prosthetics
Ø6.0 Ø6.0Ø7.0 Ø7.0Ø8.0 Ø8.0
6.0 mm8.0 mm
6.0 mm ARIPL660
8.0 mm ARIPL680 ARIPL780 ARIPL880
ARIPL740 ARIPL8404.0 mm ARIPL640
Solid Abutment Non-Trip
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120) Hand Driver (MTRD100S/MTRD100L)
Used for general cement type prosthetics
Ø6.0 Ø6.0Ø7.0 Ø8.0
6.0 mm
Height
Cuff
Ø6.0 mm 4.0 mm 6.0 mm
1 mm ARSIS641 ARSIS601
2 mm ARSIS642 ARSIS602
3 mm ARSIS643 ARSIS603
4 mm ARSIS644 ARSIS604
Ø7.0 mm 4.0 mm 6.0 mm
1 mm ARSIS741 ARSIS701
2 mm ARSIS742 ARSIS702
3 mm ARSIS743 ARSIS703
4 mm ARSIS744 ARSIS704
Ø8.0 mm 4.0 mm 6.0 mm
1 mm ARSIS841 ARSIS801
2 mm ARSIS842 ARSIS802
3 mm ARSIS843 ARSIS803
4 mm ARSIS844 ARSIS804
Abutment Screw
Short: Fixture 5 mm ARAS250
Long: Fixture 6-13 mm ARAS250L
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Abutment Screw for Temporary, EZ Post, Angled
Guide Pin
Guide Pin & Waxing Pin
10 mm ARIG300
15 mm ARIG100
20 mm ARIG200
10mm 15mm 20mm
1.2 Hex
Hei
ght
Using: 1.2 Hex Hand driver(TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Postbus 649 5000 AP TilburgTelefoon +31 (0)88 84 84 100, E-mail [email protected]
Rescue® Internal | Abutments Abutments | Rescue® Internal
© 2011 Megagen Beneulux - All rights reserved. Subject to typographical and other errors.
Postbus 649 5000 AP TilburgTelefoon +31 (0)88 84 84 100, E-mail [email protected]
Rescue® Internal | Abutments Abutments | Rescue® Internal
EZ Post Non-Trip
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Used for general cement type prostheticsAbutment Screw (Fixture 5, 6mm): Included ARAS250Abutment Screw (Fixture 7-13mm): Included ARAS250L
Ø6.0 Ø7.0 Ø8.0
Ø6.0 mm 4.0 mm 6.0 mm 8.0 mm
1 mm ARSIPN641 ARSIPN601T ARSIPN681T
2 mm ARSIPN642 ARSIPN602T ARSIPN682T
3 mm ARSIPN643 ARSIPN603T ARSIPN683T
4 mm ARSIPN644 ARSIPN604T ARSIPN684T
Ø7.0 mm 4.0 mm 6.0 mm 8.0 mm
1 mm ARSIPN741 ARSIPN701T ARSIPN781T
2 mm ARSIPN742 ARSIPN702T ARSIPN782T
3 mm ARSIPN743 ARSIPN703T ARSIPN783T
4 mm ARSIPN744 ARSIPN704T ARSIPN784T
Ø8.0 mm 4.0 mm 6.0 mm 8.0 mm
1 mm ARSIPN841 ARSIPN801T ARSIPN881T
2 mm ARSIPN842 ARSIPN802T ARSIPN882T
3 mm ARSIPN843 ARSIPN803T ARSIPN883T
4 mm ARSIPN844 ARSIPN804T ARSIPN884T
1.2 Hex Height
Cuff
EZ Post Trip-Type
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Used for general cement type prostheticsAbutment Screw (Fixture 5, 6mm):Included ARAS250Abutment Screw (Fixture 7-13mm): Included ARAS250L
Ø6.0 Ø7.0 Ø8.0
Ø6.0 mm 4.0 mm 6.0 mm 8.0 mm
1 mm ARSIP641 ARSIP601T ARSIP681T
2 mm ARSIP642 ARSIP602T ARSIP682T
3 mm ARSIP643 ARSIP603T ARSIP683T
4 mm ARSIP644 ARSIP604T ARSIP684T
Ø7.0 mm 4.0 mm 6.0 mm 8.0 mm
1 mm ARSIP741 ARSIP701T ARSIP781T
2 mm ARSIP742 ARSIP702T ARSIP782T
3 mm ARSIP743 ARSIP703T ARSIP783T
4 mm ARSIP744 ARSIP704T ARSIP784T
Ø8.0 mm 4.0 mm 6.0 mm 8.0 mm
1 mm ARSIP841 ARSIP801T ARSIP881T
2 mm ARSIP842 ARSIP802T ARSIP882T
3 mm ARSIP843 ARSIP803T ARSIP883T
4 mm ARSIP844 ARSIP804T ARSIP884T
1.2 HexHeight
Cuff
REF Code RQ601
Platform
Height 1 mm
6.0
RQ602
2 mm
6.0
RQ603
3 mm
6.0
RQ604
4 mm
6.0
RQ605
5 mm
6.0
RQ606
6 mm
6.0
Kerator
Gold Abutment
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Ø6.0 mm Trip Non-Trip
ARGA200T ARGA100T
Used for general screw type prosthetics.
Screw included.
Non-TripTrip
Snap Impression Coping
Ø6.0 mm Color REF Code
4 mm Yellow ARIIC640
6 mm White ARIIC660
8 mm Pink ARIIC680
Ø7.0 mm Color REF Code
4 mm Yellow ARIIC740
6 mm White ARIIC760
8 mm Pink ARIIC780
Ø8.0 mm Color REF Code
4 mm Yellow ARIIC840
6 mm White ARIIC860
8 mm Blue ARIIC880
Impression coping used in case of a solid abutment and EZ Post
Colour coded in accordance with abutment height
Ø6.0 Ø7.0 Ø8.0
Height
Comfort Cap
Ø6.0 mm Color REF Code
4 mm Yellow ARIC640
6 mm White ARIC660
8 mm Pink ARIC680
Ø7.0 mm Color REF Code
4 mm Yellow ARIC740
6 mm White ARIC760
8 mm Pink ARIC780
Ø8.0 mm Color REF Code
4 mm Yellow ARIC840
6 mm White ARIC860
8 mm Pink ARIC880
To protect the solid abutment and reduce discomfort
Ø6.0 Ø7.0 Ø8.0
Height
Male processing package included
© 2011 Megagen Beneulux - All rights reserved. Subject to typographical and other errors.
ExFeel® Internal | Abutments
Postbus 649 5000 AP TilburgTelefoon +31 (0)88 84 84 100, E-mail [email protected]
Abutments | ExFeel® Internal
Solid Post Abutment & Post Cap
Using: Solid Post Driver (MSD430S/L)
Height Abut. Cuff=1 Abut. Cuff=2 Abut. Cuff=3 Cap Cuff=1 Cap Cuff=2 Cap Cuff=3
4.0 mm ISPA401P ISPA402P ISPA403P ISPC401 ISPC402 ISPC403
5.5 mm ISPA551P ISPA552P ISPA553P ISPC551 ISPC552 ISPC553
7.0 mm ISPA701P ISPA702P ISPA703P ISPC701 ISPC702 ISPC703
Solid Post Abutment Solid Post CapPH
CH
Solid shoulder Analog, Pin
Bridge Material REF code
Solid shoulder analog Plastic ISLA100
Analog pin Titanium ISLA200
Solid shoulder Analog & Pin
Solid Abutment & Protect Cap
Using: Solid Driver (MSD300)
Height Abutment Protect Cap
4.0 mm ISA400P ISPC450
5.5 mm ISA550P ISPC600
7.0 mm ISA700P ISPC750
Solid Abutment
Solid Protect Cap
PH
Solid Analog
Height REF code
4.0 mm ISN400
5.5 mm ISN550
7.0 mm ISN700
Snap Impression Cap
Positioning Cylinder
Height REF-Code
7.0 mm IIPC100
REF-Code ISIC100
Octa Abutment & Healing Cap
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Using: Octa Driver (MOD300)
Octa Healing Cap Screw
2.0 mm x 0.40 pitch
IHC400T IAAS600
REF Code IOA200
Octa Abutment: Abutment for multiplebridge teeth
Octa Healing Cap
Impression & Lab Analog
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Octa Impression Coping Guide Pin
RIOG150
Octa Non-Octa Octa Analog
RIOH100T RION100T IOA300
Octa Impression Coping Pick-Up type
15mm Guide pin: included RIOG150
Octa Analog: analog for Octa Abutment
Abutment Screw
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Angled Abutment IAAS600
Octa Gold Abutment/Healing Cap IRCS200
Multi Post/Gold Abutment EXIMS100
Octa Gold Abutment
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Non-Octa Octa
Plastic sleeve white Plastic sleeve red
IOGN100T IOGO100T
Abutment Screw: Included IRCS200
Non-Octa Octa
Octa Plastic Abutment
Using: 1.2 Hex Hand driver (TCMHDL1200 or TCMHDS1200) or 1.2 Hex Right angle driver (MDR120)
Non-Octa Octa
Plastic white Plastic red
IOPN100T IOPH100T
Abutment Screw: Included IRCS200
Non-Octa Octa
Notitie:
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Postbus 649 5000 AP TilburgTelefoon +31 (0)88 84 84 100, E-mail [email protected]