RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B series

GOALS:

• KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS

• DEDICATED TO OEM’s MARKET AND REPLACEMENT

• COMPLETE RANGE OF PERFORMANCES:– EN 676

– LOW NOx

– ALL KIND OF GASES G20, G21, G25, LPG (by a KIT)

– BOTH CONVENTIONAL FLUE (CF) & BALANCE FLUE (BF)

Page 3: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B series

MAIN FEATURES: AIR FLOW

• AIR PASSAGES DESIGNED TO OBTAIN:– SMALL DIMENSIONS, BUT HIGH PRESSURE

– LOW NOISE

– FINEST SETUP

– EASY MATCHING WITH BOILERS

– PERFECT BALANCE FLUE

Page 4: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

AIR PASSAGES DESIGNED TO OBTAIN:SMALL DIMENSIONS, BUT BIG PRESSURE

COMPARISON

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B series

Page 5: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

EN 303.2

R 40 GS 5

AIR PASSAGES DESIGNED TO OBTAIN:SMALL DIMENSIONS, BUT BIG PRESSURE

RDB 1S

RBD 1S - WORKING FIELD

0

0,5

1

1,5

2

2,5

10 20 30 40 50 60

Capacity [kW]

Res

ista

nce

[m

bar

]

Page 6: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

AIR PASSAGES DESIGNED TO OBTAIN:LOW NOISE

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B series

Page 7: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B series• FINE AIR ADJUSTEMENT

678

9

Page 8: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B series5 6

123

4

• FINE AIR ADJUSTEMENT

Page 9: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

Page 10: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B series

Page 11: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B seriesMAIN COMPONENTS

CONTROL BOXLMG 25.33OB27

Page 12: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B seriesCONTROL BOX LMG25.33OB27

FEATURES:

# Undervoltage AC 160 V# Electrical polarity must be respected

# Flame signals: operation reliable value min 2µAat beginning max value 0.5µA

# El. supply 230 VAC +10 -15%---50-60Hz

Page 13: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS

R D BR D B seriesR D BR D B seriesControl program in the event of fault:

If a fault occurs, all outputs will immediately be deactivated (< 1 s)On restoration of power, a restart will be made with the full program sequenceIf the operating voltage drops below the undervoltage threshold, a restart will be made with the full program sequenceIf there is a premature faulty flame signalLockoutIf the contact of the air pressure monitor «LP» has welded in the working position, start up will be preventedand, after 65 seconds, lockout initiatedIf the contact of the air pressure monitor «LP» has welded in the idle position: lockoutat after 52.5 secondsIf the burner does not ignite by the end of safety time LockoutIf flame is lost during operation: Three repetitions

Lockout:

Lockout cannot be changed and takes place 10 seconds after safety shutdown. A main voltage failure during that period of time wil lead to a restart.

Resetting:

When never lockout occurs, the burner control can immediately be reset. To do this, keep the lockout reset button depressed for a minimum of 0.5 seconds and a maximum of 3seconds!

Page 14: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

N ?

8

REMOTE RESET IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

ELECTRICAL MODE OPERATION

Page 15: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

0”

open the gas first...

Page 16: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

0”

open the gas first...

Page 17: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

0”

…waiting time...

Page 18: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…waiting time...

2.5”

Page 19: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…pre-purge begins...

2.5”

Page 20: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…pre-purge...

…air pressure grows...

…the air pressure switch moves...

Page 21: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…pre-purge...

7.5”

…max time for theair pressure switchto move...

Page 22: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…pre-purge...

Page 23: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…pre-ignition..

min 37.5”

Page 24: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…pre-ignition..

min 37.5”

Page 25: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…pre-ignition..

…2”...

Page 26: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…ignition..

…2”...

Page 27: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…ignition..

Page 28: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…ignition..

…the flame signal mustbe detected within 3”...

Page 29: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

STARTINGPROCEDURE

…ignition..

Page 30: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

OPERATION

Page 31: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

BURNER OFF

Page 32: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

BURNER OFF

Page 33: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

N L2L1

32 102

12

PG2

1

3

2

3

3

3

M

LINE F1LOAD

XP2

XP3

X2

X3

VSV1

BL

UE

W.

BL

AC

K

BROWN

RED

PA

4

N

N

N

1

7

3 6 11

XP1

X1

TS

TL

L N

IGN. TRANSFORMER

THERMOSTAT

GAS VALVE

FLAME SIGNAL

REMOTE RESET

AIR P.SWITCH

FAN MOTOR

LOCK OUT

BURNER OFF

Page 34: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

Operating concept

Burner control has initiated lockoutRed fault LED on

Reset Press lockout reset button for 0.5...3 s

Diagnosis of cause of fault – Wait > 10 s– Press lockout reset button for > 3 s– Read blink code of red fault LED

«Error code table A»

Burner control in operation Green flame signal LED on

Restart Press lockout reset button for 0.5...3 s

Read flame establishment time – Press lockout reset button for > 3 s– Read blink code of green flame signal

«Code table B»

SELF-DIAGNOSTIC

Page 35: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

Error code table A

Blink code Possible cause

2 x No establishment of flame at the end of «TSA»– Faulty or soiled detector electrode

– Faulty or soiled fuel valves– Poor adjustment of burner

3 x Air pressure monitor does not close– «LP» faulty

– «LP» incorrectly adjusted – Fan motor does not run

4 x Air pressure monitor does not open or extraneous light on burner startup

– «LP» faulty– «LP» incorrectly adjusted

5 x Extraneous light during pre-purging– Or internal device fault

7 x Loss of flame during operation– Poor adjustment of burner

– Faulty or soiled fuel valves – Short-circuit between detector electrode and ground

8...17 x ; Free

Page 36: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

Error code table A

Blink code Possible cause

18 x Air pressure monitor opens during pre-purging or operation

– «LP» incorrectly adjusted– Four times loss of flame during operation

19 x Faulty output contact – Wiring error – External power supply on output terminal

20 x Internal device fault

Page 37: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

Code table B

Blink code Flame establishment (limit 3 s)

1 x 0.4 s 0.4 s

2 x 0.8 s 0.8 s

7 x 2.8 s 2.8 s

Page 38: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

GAS LINE (both natural gas & LPG)

VALVE GROUP

MBDLE 055 D01

18

17

15

16

1413

12

1110987

3

1

2

4 5 6

A BC

1. Microfilter2. Inlet P1 (max 65 mbar)3. Housing4. Spring, gas pressure regulator5. Diaphragms, gas pressureregulator6. Cover (side, left)7. Nozzle8. Outlet P3 (3 ÷ 15 mbar)9. Main flow restrictor10. Start gas restrictor11. Damper12. Central chamber connection13. Servopressure regulator14. Adjustment screw - main flow15. Reference value adjustmentdevice - pressure regulator16. Adjustment screw - start flow17. Solenoid housing V1, V218. Electrical connection

D

The gas flow is released throughchambers A, B, C and D of the GasMultiBloc.

V1 V2

Page 39: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

START FLOW

0102030405060708090

100

0 1 2 3 4 5 6 7 8

t[s]

Q [

%]

Performance can be adjustedTime cannot be adjusted

Start-up response

Time

gas

flo

w

Page 40: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

Flow pressure characteristic

1

10

100

0,1 1 10 100

[m3/h]

[mb

ar]

Density [kg/m3]

f

Liquid gas 0.58 0.624Town gas 2.08 1.18

Natural gasV gas used = V natural gas x f

Page 41: RESIDENTIAL GAS BURNERS

Burners TRAining CEntre

Head pressure losses (ref.G20)

0

1

2

3

4

5

6

10 20 30 40 50

capacity [kW]

resi

stan

ce [

mb

ar]


Recommended