Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm Author: Minh Anh Nguyen Colorado State University School of Biomedical and Electrical Engineering Email: [email protected]
Transcript
Page 1: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Author: Minh Anh NguyenColorado State University

School of Biomedical and Electrical EngineeringEmail: [email protected]

Page 2: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Outline of the review• Update on tasks from the previous

meeting• Microphone prototype• LabView Results for detecting

methods/algorithms for audio files

Page 3: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Update on labView

• Need: Vision and Motion package to analyze the images

• Issue: – The Vision and Motion programming/function

package is missing or not available for the Labview 2014 and NI myRio software

• This issue is resolved

Page 4: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Image test• Simulation mode– Make sure image files are loaded into the workspace

without any issues.– Make sure a correct file is loaded– Plot histogram of the image– Verify that the histogram value is correct.– Positive test: load two image files which have 2

different images and verify that the test results show the difference.

– Negative test: load two image files which have 2 similar images and verify that the test results show the same thing or match.

Page 5: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Labview results for comparing two images which are identical

Page 6: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

LabView results for comparing two images which are not identical

Page 7: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

LabView results for comparing two images which are not identical

Page 8: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Audio test• Simulation mode– Make sure audio files are loaded into the workspace

without any issues.– Plot and listen to audio files; make sure a correct file is

loaded.– Verify that the FFT value is correct.– Positive test: load two audio files which have 2

different signals and verify that the test results show the difference.

– Negative test: load two audio files which have 2 similar signals and verify that the test result show the same thing or match.

Page 9: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Microphone prototype for correct setting

Page 10: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

LabView results for comparing two audio files which are identical

Page 11: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Microphone prototype for hex pin not popped out

Page 12: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Result of hex pin not popped out after executing the device for 1 min

Page 13: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

LabView results for comparing two audio files (hex pin) which are not identical

Page 14: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Microphone prototype for upper arm not correctly set

Page 15: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

LabView results for comparing two audio files (upper arm) which are not identical

Page 16: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Microphone prototype for upper arm not correctly set

Page 17: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

LabView results for comparing two audio files (upper arm) which are not identical

Page 18: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

Microphone prototype for lower bearing not correctly set

Page 19: Results Review of Microphone Prototype and LabView Detecting of Human Errors Algorithm

LabView results for comparing two audio files (lower bearing) which are not identical