REVISIONS BY Signature will be under my observation. This work was prepared by me or under my supervision, construction of this project construction of this project me or under my supervision, This work was prepared by M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-01.dgn 11/22/2013 75-5944 Kuakini Hwy. #2 Pete Piper 331-2244 Kailua-Kona, HI 96740 PIPER DESIGNS JOB # : DRAWN : DRAWING: SCALE : DATE : SHEET SHEETS OF I I A W A H U . S . A . PROFESSIONAL ARCHITECT AR 11532 LICENSED S Y F E J G L. E R F S O R EXPIRES 04/30/2014 PD A PROPOSED NEW RESIDENCE FOR: P13-026 PJP 15 1 1 HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 PERSPECTIVE VIEW N/A SHEET INDEX DESCRIPTION SHEET 1 PERSPECTIVE 2 FRONT & RIGHT ELEVATIONS LEFT & REAR ELEVATIONS SECTIONS 8 7 6 5 4 3 9 REFLECTED CEILING PLAN 10 FOUNDATION PLAN 11 12 13 14 FLOOR PLAN (1ST FLOOR) FLOOR PLAN (2ND FLOOR) FLOOR FRAMING PLAN ROOF FRAMING PLAN GENERAL NOTES PROJECT DATA LOT AREA 1.936 ACRES FRONT & REAR SETBACKS SIDE SETBACKS LIVING AREA (TOTAL) ENTRY AREA GARAGE AREA ACCESSORY AREA (TOTAL) 2,513 SQ FT 768 SQ FT 800 SQ FT 459 SQ FT 3,543 SQ FT 3,133 SQ FT 20.00’ 30.00’ LIVING AREA (1ST FLOOR) LIVING AREA (2ND FLOOR) EFFECTIVE WIND SPEED BASIC WIND SPEED ROOF LIVE LOAD FLOOR LIVE LOAD E 40 PSF 14 PSF 105 MPH ZONING WIND EXPOSURE CATEGORY (REF. R301.2.1.4) SEISMIC DESIGN CATEGORY (REF. FIGURE 301.2(2)) C 2006 IBC, 2006 UPC, 2008 NEC CODES 120 MPH A NEW RESIDENCE FOR: SITE PLAN ROOF PLAN A-20a LANAI AREA (1ST FLOOR) LANAI AREA (2ND FLOOR) 128 SQ FT BREEZEWAY AREA 70 SQ FT WORKSHOP AREA 288 SQ FT 410 SQ FT STEPHEN & MICHELLE SAKOMAN STEPHEN & MICHELLE SAKOMAN 11/18/2013 ELECTRICAL PLANS 15 WALL SECTIONS Signature Date Title License No. I CERTIFY THAT THE DESIGN IS IN CONFORMANCE WITH THE BUILDING ENERGY EFFICIENCY STANDARDS PERTAINING TO: SECTION 502 BUILDING ENVELOPE HAWAII COUNTY CODE - CHAPTER 5 - BUILDING BUILDING ENERGY EFFICIENCY STANDARDS 2006 IECC & ORDINANACES 09-48 & 10-68 SECTION 503 BUILDING MECHANICAL SYSTEMS SECTION 504 SERVICE WATER HEATING (MANDATORY) SECTION 505 ELECTRICAL POWER & LIGHTING SYSTEMS NOTE: THIS PROJECT IS LOCATED IN A "WIND BORNE DEBRIS REGION" AND THEREFORE ALL GLAZINGS SHALL BE PROTECTED WITH AN IMPACT-RESISTANT COVERING CONSISTING OF 7/16" THK PLYWOOD PER 2006 IBC 1609.1.2.
Transcript
Page 1: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-01.dgn 11/22/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

11

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

PERSPECTIVE VIEW

N/A

SHEET INDEX

DESCRIPTIONSHEET

1 PERSPECTIVE

2

FRONT & RIGHT ELEVATIONS

LEFT & REAR ELEVATIONS

SECTIONS8

7

6

5

4

3

9 REFLECTED CEILING PLAN

10

FOUNDATION PLAN11

12

13

14

FLOOR PLAN (1ST FLOOR)

FLOOR PLAN (2ND FLOOR)

FLOOR FRAMING PLAN

ROOF FRAMING PLAN

GENERAL NOTES

PROJECT DATALOT AREA 1.936 ACRES

FRONT & REAR SETBACKS

SIDE SETBACKS

LIVING AREA (TOTAL)

ENTRY AREA

GARAGE AREA

ACCESSORY AREA (TOTAL) 2,513 SQ FT

768 SQ FT

800 SQ FT

459 SQ FT

3,543 SQ FT

3,133 SQ FT

20.00’

30.00’

LIVING AREA (1ST FLOOR)

LIVING AREA (2ND FLOOR)

EFFECTIVE WIND SPEED

BASIC WIND SPEED

ROOF LIVE LOAD

FLOOR LIVE LOAD

E

40 PSF

14 PSF

105 MPH

ZONING

WIND EXPOSURE CATEGORY (REF. R301.2.1.4)

SEISMIC DESIGN CATEGORY (REF. FIGURE 301.2(2))

C

2006 IBC, 2006 UPC, 2008 NECCODES

120 MPH

A NEW RESIDENCE FOR:

SITE PLAN

ROOF PLAN

A-20a

LANAI AREA (1ST FLOOR)

LANAI AREA (2ND FLOOR)

128 SQ FTBREEZEWAY AREA

70 SQ FT

WORKSHOP AREA 288 SQ FT

410 SQ FT

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

STEPHEN & MICHELLE SAKOMAN

11/18/2013

ELECTRICAL PLANS15

WALL SECTIONS

Signature Date

Title

License No.

I CERTIFY THAT THE DESIGN IS IN CONFORMANCE WITH THE BUILDING

ENERGY EFFICIENCY STANDARDS PERTAINING TO:

SECTION 502 BUILDING ENVELOPE

HAWAII COUNTY CODE - CHAPTER 5 - BUILDING

BUILDING ENERGY EFFICIENCY STANDARDS

2006 IECC & ORDINANACES 09-48 & 10-68

SECTION 503 BUILDING MECHANICAL SYSTEMS

SECTION 504 SERVICE WATER HEATING (MANDATORY)

SECTION 505 ELECTRICAL POWER & LIGHTING SYSTEMS

NOTE:

THIS PROJECT IS LOCATED IN A "WIND BORNE DEBRIS REGION" AND THEREFORE

ALL GLAZINGS SHALL BE PROTECTED WITH AN IMPACT-RESISTANT COVERING

CONSISTING OF 7/16" THK PLYWOOD PER 2006 IBC 1609.1.2.

Page 2: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-02.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

3. All excavations shall be free of loose dirt, water, or debris prior to placing concrete.

4. Footings shall be to the depth below grades indicated on the plans.

6. Concrete contractor shall ensure a true and level foundation prior to placing concrete.

8. Concrete contractor shall verify and locate all door openings and avoid placement of

anchor bolts in these locations.

11. All reinforcing steel, mesh, bolts,tie downs, hold downs, inserts, etc. shall

be in place and well secured before pouring concrete.

14. Reinforcing steel shall be as per plans and details and shall conform to the

followings:

A. All reinforcing steel shall be new, stock, deformed bars conforming to

A.S.T.M. A-615 grade 50 and A-305

B. Lap all bars 40 diameter (1’6" minimum) in concrete.

C. Stagger all horizontal splices.

D. All bar bends shall be made cold.

E. All bars shall be free of rust, grease, mill scale, or any material which

might effect its bond to the concrete.

F: Place all reinforcing bars in trenches 3" of bottom of trench and within

6" of top of foundation wall. Refer to foundation plan for size, quantity

of location of all bars

1. Concrete block units for hollow masonry construction shall be grade N units conforming

to A.S.T.M. C-90

2. Vertical reinforcing bars in walls shall be placed in center of wall unless otherwise

noted.

3. All vertical cells shall be grouted in lifts not to exceed 4’-0" in height. All

vertical cells shall have a clear, unobstructed, continuous cell measuring not less

than 2"X3".

4. Vertical bars in masonry are to be tied or otherwise fixed in position in intervals of

not less than 4’-0" and at the top and bottom.

5. Provide inspection and clean out holes at base of vertical cell grout lifts which are

more than 4’-0" in heght.

6. When grouting is stopped for one hour or longer, horizontal construction joints shall

be formed by stopping the pour of grout 1-1/2" below the top of the uppermost unit

9. Furnish and install 1/2 " diameter bolts at 24" o.c. vertically where stud walls

and masonry walls adjoin.

10. Reinforcing steel shall be as per plans and details and shall confirm to item #16,

concrete footings and slabs

DIVISION 5 - METALS: The metal building shown on the drawings shall be engineered and shop drawings

provided to the architect by metal building manufacturer; GARCO, WEDGECORE or equal. All metal

building details, structural drawings and so forth shall be submitted to the architect for

approval. Second floor warehouse space of metal building shall be designed to accommodate 125 lbs.

of total load per square foot including dead load and live load. Metal building shall be designed

by the manufacturer with all standard manufactured details incorporated that is typical window and

door details, typical continuous roof details, typical ridge detail, typical downspouts and drain

detail.

2. All welding shall comply with AWS D1, 1-76 using E70 electrodes.

3. All bolts shall comply with A.S.T.M. A307 and A325X.

5. All welding shall be inspected and approved by a certified welding inspector.

A. Studs 2X4 : Stud grade or better

B. Studs 2X6: Construction grade or better.

C. Posts 2" to 4" thick, 6" and wider: No. 2 or better.

D. Posts 5X5 and wider: No. 2 or better.

E. Roof and Floor Joists: No. 1 and better.

F. Beams and Stringers: No. 1 or better.

G. Plates: No. 2 or better.

H. Headers: No. 1 or better.

I. Bracing and Blocking: utility grade or better.

L. Shear Panels: Struc. I, Struc. II, or standard grade as noted on plans.

M. Structural plywood shall be structural I with exterior glue in accordance

U.S. Products StandardPS-1-74.

N. Wood or Masonite Siding: Refer to building plans and elevations for siding.

DIVISION 6 - WOOD AND PLASTICS:

NAILING

2. Refer to shear panel schedule on plans for special nailing of plywood and/or

gypsum wallboard shear panels.

3. Refer to plans for nailing of all floor and roof sheathing.

ROUGH CARPENTRY

1. Rough carpentry shall include but not be limited to all of the following items.

6. Cutting and boring of wood studs shall be as follows:

A. In exterior walls and bearing partitions, any wood stud may be cut or

notched up to depth not exceeding 25% of the width of the stud.

B. In non-bearing partitions, any wood stud may be out or notched up

to a depth not exceeding 25% of the width of the stud.

D. A hole not greater in diameter that 40% of the stud width may be bored

in any wood stud.

E. All holes for bolts shall be fitted with steel plate washer. Holes shall be

drilled with a bit 1/32: to 1/16 " larger than the bolt.

G. Immediatly prior to covering, all bolts and lag screws shall be tightened.

H. Where plumbing, heating, or electrical members are placed in a partition

requiring the cutting of studs or double top plate a steel strap shall be

fastened to each side of the member. Strap shall be 1/8 "X1-1/2"X24"

long and shall be fastened with 6-16d nails at each end where plates are

interrupted.

8. Top plates of all stud walls shall be two peices same size as studs except as shown

otherwise. Lap 48" minimum with not less than 6-16d nails at each lap not more

than 12" between nails. Provide 1/8 "X1-1/2"X24" with 6-16d nails at each end

where plates are interrupted.

9. Where wood trusses rest on top plates use shear blocking and nailing as shown

on plans.

10. Install all shear panels as shown on plans with appropriate metal straps and ties.

11. All sheathing and shear walls shall be inspected and approved prior to covering.

12. Install all 2X backing as required for all items needing same.

13. Install 2X fireblocking at all concealed spaces and all spaces 10’-0"

or more in height or length.

14. Install all wood trusses and truss company furnished blocking per plans

and truss drawings (furnished by truss company).

15. Install all truss to wall clips as shown on plans.

17. Double floor joists under parallel partitions above and double solid block

under partitions above perpindicular to floor joists.

18. Install all floor joists with their natural crown up.

20. All wood floors shall be level and free of any lumps or depressions.

21. Framming contractor shall install temporary wood railing at balconies and stairs

and shall remove them when directed by the contractor.

22. Block or bridge all floor joists at 8’-0" maximum intervals.

23. All flushed framed members shall be installed with approved metal connectors.

25. Install all exterior glass doors and windows and lay frames in a bead of approved

caulking. Sisalkraft flash all doors and windows. Refer to plans for flashing

details.

FINISH CARPENTRY

2. All door frames shall be "pre-hung" unless noted otherwise on plan.

3. Install medicine cabinets, paper holders, towel bars, door stops shelves and rods,

door hardware interior and exterior doors and frames, casing trim, mouldings,

etc. as needed.

4. Use countersunk, finish nails on all exposed items. No hammer marks, gouges

or other marks will be acceptable.

DIVISION 7 - THERMAL AND MOISTURE PROTECTION: All windows and doors and construction

joints shall be caulked with DAP, silicone caulk or equal.

SHEET METAL

1. All sheet metal flashing shall be 26 guage galvanized iron or approved

bonderized metal.

2. Install all roof dormer vents as shown on plans.

3. Furnish and install all miscellaneous flashing not covered by other trades.

5. Refer to plans for specific areas which require special attention. This shall

include but not be limited to flashing at two story buildings in the area of

balcony to wall/door intersections and flashing sleeves at posts connected to

balcony.

GLAZING

2. Glazing at doors shall be tempered glass within 24" of a door and 60" of the floor.

3. Doors and windows between conditioned and unconditioned spaces such as garages

and closets for central forced air gas furnaces (which use outside combustion air)

shall be fully weather stripped.

4. Manufactured door and windows shall be certified and labled indicating that they

meet the appropriate standards.

DIVISION 9 - FINISHES: All floors to be free of dirt and other debris and made ready for interior

finish of vinyl, carpet, or equal. All carpet and pad shall be selected by owner.

GYPSUM WALLBOARD

2. Typical one hour unit division wall is continuous to roof sheathing.

3. All joints of gypsum wallboard exposed in a habitable space shall be taped and

nails float coated prior to painting.

4. Texture of gypsum wallboard shall be verified with general contractor prior to finish.

5. Gypsum wallboard is used in some cases as shear walls and special care must

be taken to insure proper nailing. Drywall contractor will be held responsible

for correct nailing and type of wallboard.

6. Drywall contractor shall be held responsible for the cost of uncovering and

repairing all gypsum wallboard that has covered electrical outlet boxes,

including the repainting of the wallor walls.

CERAMIC TILE

1. All installation shall comply with applicable parts of ANSI A108 series of tile

installation standards. Installation system numbers refer to requirements of TCA

(Handbook for Ceramic Tile Installation).

PAINT

4. Exterior siding: Siding that is manufactured preprimed shall receive two coats of

exterior latex semi-gloss paint. Siding that is not preprimed shall receive one

coat of latex primer and two coats of semi-gloss exterior paint.

5. Wet areas i.e. kitchen and or restrooms: All areas to have one coat primer

and 2 coats of enamel.

6. Upon completion of work all staging, scaffolding and containers shall be

removed from the sight. Paint spots, oil or stains upon adjacent surfaces

shall be removed and the entire job be left in a clean and acceptable

condition.

DIVISION 15 - MECHANICAL: All plumbing materials and labor shall comply with the

requirements of all the authorities having jurisdiction over the work. All materials and

equipment shall be new, free from defects, of top quality and entirely suitable for the

intended use. Contractor shall select manufacturer’s brand or trade name as used

herein are intended to establish the standard of quality in performance. All fixtures

and trim including any piping exposed to view such as lavatory connections shall

be chrome plated brass and shall include an escutcheon on all piping if exposed

or within a cabinet.

1. Installation of all fixtures properly connected.

2. Complete domestic hot and cold water system including connection to city

lines. Gate valve to meter at property line.

3. Complete water system including vents and connection to sewer as located

on drawings.

4. Provide and install hot water heater with connection by electrical contractor

when required on plans.

5. Clear width at water closets shall be 30" min.

6. Materials:

A. Cleanouts - IBOC with plastic rings.

B. Hose Bibs - Zum or equal

C. Copper Tubing - Type "L" hard drawn. (Type "K" under slab w/plastic

sheath @ slab penetrations).

D. Fittings For Copper Tubing - Wrought or cast copper standard weight.

E. Brass Pipe - ASTM B-43, standard weight, iron pipe size.

F. ABS Plastic Pipe and Fittings - Sanitary soil, waste, and vents.

G. Gas Lines - Black pipe (steel) shall meet all code requirements for

underground piping.

7. Install presure releif valves as required.

8. Install anti-siphon valves as required.

9. Install screw driver stops at all tubs and showers (valves) or equal.

10. Install dishwasher delivered to site unless not required per plans.

2. All colors and color schedules shall be approved by the owner prior to

installation of material.

1. Provide 3/4 " diameter X 20" long UFER ground at electrical services.

2. Provide a sub-panel at each unit.

4. Provide a duplex outlet for each appliance.

3. All bathroom and exterior outlets shall have a ground fault interrupter or as

required by local codes.

7. Provide phone outlets as shown on plans.

8. Provide an approved smoke detector as shown on plans.

9. Verify location of all outlets and switches prior to installation of finish wall

material.

12. Quiet toggle all switches.

11. All outlets up 12" from floor except up 42" at kitchen and up 42" at bath

pullman

14. Electrical Contractor shall supply and install all light bulbs and flourescent

lamps for fixtures.

17. Aluminum wire #4AWG and smaller shall not be used in electrical wiring.

18. Luminous ceilings shall be as per R.C.A. 7-67.

MISCELLANEOUS

15. Electrical contractor shall install and connect kitchen hood, cook unit

(if electrical) appliances, fixtures supplied by contractor or owner including

but not limited to all light bulbs.

2. Some divisions of these specifications may not be applicable to this project.

Contractor to verify soil bearing capacity to be 2,000 P.S.F. unless otherwise noted. All footings

to bear in competent bearing material.

2. All framing lumber shall be Douglas fir-larch, S4S, unless otherwise noted. The

following grades shall be the minimum acceptable grades:

FRAMING LUMBER

9. Concrete contractor shall furnish and install all of the following:

A. Anchor bolts of the size and spacing shown on the plans.

B. Reinforcing steel and dowels.

C. Wire mesh.

D. Column bases, tie downs, and hold downs as per plans.

E. Any other templates as shown on plans.

4. Connected members shall bear only upon the unthreaded portion of bolts.

DIVISION 4 - MASONRY: All stone veneer shall be applied in a workmanlike manner and secured to the

wall with metal fasteners at 24" o.c. both vertically and horizontally. The type of stone and

style shall be determined by contractor. All masonry shall be constructed as indicated on the

drawings and appropriate reinforcing steel as indicated on the drawings. All masonry CMU units

shall be grouted solid.

4. Grade Identifacation - All lumber and plywood should be clearly marked with the

grade. All framming wood to be wolmanized and all cut ends be brush treated.

2. Layout of all walls on slabs shall be the responsibility of the framing

contractor. Any discrepancies by other trades shall immediately be reported to the

general contractor.

19. All framing connectors shall be "Simpson" Strong Tie or approved equal

as noted and shown on plans. All connectors shall be I.C.B.O. approved and

installed accordingly.

7. Finish surface concrete slabs & footings shall be a minimum of 6" above grade.

4a. Provide double studs at wall ends that do not abut or connect to other walls..

GENERAL NOTES

5. All studs shall be continuous and uninterrupted for the entire length of the

wall unless supported laterally by ceiling, floor, rafter joists perpindicular to

the wall. The maximum allowable height for studs at 16" o.c. shall be 10’-0"

for 2X4 studs, 14’-0" for 2X6 studs or 3X4 studs, and 20’-0" for 2X8 studs.

Mid-span blocking shall be provided when maximum spans are used.

1. Structural steel shall conform with A.S.T.M. specifacation A35. Steel pipes shall

comply with A.S.T.M. 453, grade B. Steel tubes shall comply with A.S.T.M. A501

K. All trim members: Casings, moulding and other exterior wood shown on

drawing shall be Douglas Fir select for appearance. Facias and trim shall

be select for appearance.

1. All nailing shall be as per 2006 IBC and all nails subject to weather shall be

non-corrosive type.

1. All glass over 9 square feet in area within 18" of floor or grade and glass doors,

wall panels of bathtub and shower enclosures shall be laminated, fully tempered

or wire glass.

7. All work to conform to IBC 2006 edition.

1. The following are names and brands of materials which the architect suggests as

brands the contractor should use. Paints as manufactured by any of the following

manufactures will be considered acceptable: Sherwin Williams, Pittsburgh Plate &

Glass Co., Dupont, Benjamin Moore Company, Fuller O’brien Company, and Ameritone.

All paints shall conform to the applicable federal standards for this type and

shall be the best grade of its type. Materials shall be the type recommended by

the manufacturer for that particular purpose.

3. Exterior painting: Wood surfaces shall receive one coat of primer, and

two coats of exterior paint.

6. Electrical outlets shall be spaced 12’-0" maximum along walls, including

sliding glass doors, glass walls and any space 2’-0" or more in width.

1. Attic access shall be as per section 1209.2

16. Lamps used in luminaries for general lighting in kitchens and bathrooms shall

have an efficiency of not less than 25 lumens per watt. Lighting to be used

only for specific visual tasks or decorative effect can be exempt from this

requirement.

DIVISION 1 - SPECIFICATIONS: The specifications and drawings for this work have been prepared

in accordance with generally accepted engineering practices to meet the minimum requirements

of the 2006 edition of the International Building Code (IBC) as amended. The specifications and

drawings indicate the finished structure. It is the intent and meaning of these drawings and

specifications to provide for and secure a first class workmanlike job of high quality from all

subcontractors. The contractor shall be responsible for the construction methods, procedures, and

the conditions (including safety). The contractor shall adhere to all laws, codes, and ordinances

which apply to this work. It is understood and agreed that the work shall be completed and

performed according to the true intent, meaning and spirit of the contract documents, and should

anything be omitted from the contract documents, which are intended to cover all the work necessary

to complete the project in a first class workmanlike manner, then the contractor shall secure

instructions from the architect before proceeding with the affected or to be affected by such

omissions or discrepancies. Where several materials are specified by name for one use the

contractor may select for use any of those specified. Should any materials be found defective or

in any way contrary to the specifications of these materials, no matter in what state of

completion, will be rejected by the architect and shall be replaced by the contractor with material

complying with the construction documents Shop drawings shall be presented in a clear and

thorough manner. Details shall be identified by reference to the sheet and details or drawings

shown on contract documents. Items requiring general shop drawings and/or product data submittals

are: windows and doors, finish hardware, structural steel, all cabinet work, and all light

fixtures. Do not scale drawings due to reproduction distortion. These plans are the property of

the architect. No copies of these plans shall be made without the express written consent of the

architect. Any use of these plans or alteration of these plans for other than the owner herein

described shall be a violation of the copyright law. If at any time the ownership of the project is

sold or conveyed to new owners other than the architect has contracted with, then the

responsibility for that work is no longer in force. If the new owner proceeds with the

construction of the plans, it will be necessary for the new owner to enter into a new contractual

agreement with the architect.

DIVISION 2 - SITEWORK: The site shall be scraped of all organic vegetation prior to construction

unless noted otherwise in the plans. All excavation and leveling in preparation for the pre-slab

shall be determined by the contractor. All soils treated with poison prior to pouring of slab.

Verify all

grades, lines, levels, locations, and dimensions shown on the drawings. Report any errors and

inconsistencies in above to architect before commencing of work. All elevations shown on the

contract documents are based on the topographic survey. Contractor and each subcontractor

shall verify dimensions at site for all built-in work and for work adjoining that of other trades

and for dimensions shown. Excavation for footing shall be carried to competent bearing material as

called for on foundation drawing. Rock, debris, and unsuitable fill material or excess resulting

from excavations shall be removed from site. Back fill shall be formed by grading approved

excavation material in uniform horizontal layers not more than six inches deep, loose measure,

adding water as required to achieve optimum water content, and compacting by means of

tamping or rolling or other methods as approved. Rough grade at building allowing for top soil

in lawn and planting areas. Finish building floor as indicated on finish elevations and drawings.

Finish surface reasonably smooth and even and conform to elevations on drawings.

DIVISION 3 - CONCRETE: All concrete slabs shall be reinforced as indicated on drawings. Footings

and wall thickness shown on the drawings are minimums. Building paper shall be provided between

wood and concrete unless wood is pressure treated with approved preservative marked by the

approved agency. Expansion joints shall be provided in the concrete slab as shown on the drawings.

Exterior slabs to have broom finish 90 degrees to direction of maximum traffic.

1. Unless otherwise specified all concrete shall be mixed and proportioned to develop a

compressible strength of 2,500 pounds per square inch (p.s.i.) at 28 days, using a

water cement ratio 6-1/2 gallons of water to the sack of cement. Maximum slump of

four inches. Use set retarding add mixture during hot weather only when acceptable to

architect. Concrete driveways and sidewalks on fill shall develop a compressible

strength of 2,500 p.s.i. at 28 days using a water cement ratio not more than 7-1/4

gallons per sack of cement. All concrete subject to exterior exposure shall contain

entrained air.

5. All forms shall be constructed to maintain the required position and shape during and

after the placing of concrete and be sufficiently tight to prevent the leakage of

concrete. All slab work ten feet (10’-0") or more in length shall vary no more that 1/8 "

10. Concrete shall not be placed until trenches, forms, and all reinforcing steel have

been inspected and approved by the building official.

12. All anchor bolts shall be 1/2 " diameter X 10" long, embedded 7" into concrete, 4’-0"

maximum o.c. and 12" maximum from all plate ends and corners of building. Refer to

plans for different sizes and spacing of anchor bolts.

13. Concrete subcontractor shall be responsible for stripping of all forms and stakes

when slab and footings are sufficiently cured.

7. Mortar and grout shall attain a compressive strength of 2,000 p.s.i. at 28 days

Mortar shall be type S in accordance with A.S.T.M. C270. Proportioned by volume.

1 part Portland cement, 1/4 part dry, hydrated lime, 2-1/2 parts pea gravel. Grout mix:

1 part Portland cement, 2 to 3 parts sand, 2 parts pea gravel.

8. All isolated bolts, straps or templates embedded in masonry shall be grouted solid in

place with 2" of grout surrounding bolt.

11. Rough stone: The concrete reinforced masonry walls shall be constructed of size and

shapes as specified on contract drawings. All reinforcing steel shall be that as

specified on drawings. Contractor shall notify architect on time of completion of

footings for inspection prior to beginning construction of CRM walls.

1. All framing lumber shall conform with the provisions of the American Softwood

Lumber Standard PS-20-70 and each piece shall bear the grade stamp of an approved

grading agency. All clear wood shall conform to A.S.T.M. D2555 and all structural

grades shall conform to A.S.T.M. D245. Sawn lumber calculations are based on

standard grading rules of WWPA.

J. Foundation Plates or Mud sills shall be pressure treated Douglas Fir or

foundation grade Redwood (Section 2905-L)

3. All structural lumber shall be preservative treated per 2006 IBC 2303.1.8.

5. Moisture content of all lumber, rough or finished, shall not exceed 19%.

3. Mud sills and sole plates shall be securely fastened to slab or floor with

anchor bolts of the size and spacing shown on plans. Provide 30 pound

asphalt saturated felt under all sills and sole plates at exterior.

4. Interior non-bearing walls and bearing walls where shown on plans shall be

fastened with power driven fasteners (7/32" O Ramset #3348), per I.C.B.O.

Report #1147 or approved equal, fastener shall be 32" o.c. or as shown on

plans with first two fasteners 7" and 10" from each cut end.

C. Bored holes not greater than 65% of the width of the stud are permitted in

non-bearing partitions ar in any any wall where each stud is doubled,

provided that in no case the edge of the bored hole be nearer than 5/8 "

to the edge of the stud.

F. Bolts in wood shall not be less than 7 diameters from the end and 4 diameters

from the edge.

7. Provide horizontal 2X solid blocking in all partitions at mid-height.

16. 2X solid blocking @ 8’-0" o.c. at all joists and rafters with spans greater than 8’-0".

24. Provide one (1) layer of Tyvek or equivelent moisture barrier under all exterior

wall finishes unless noted otherwise on plans.

1. Install all interior trim. Door frames shall be Douglas Fir, finger joint or

approved equal. Door casing shall be Douglas Fir, finger joint or approved

equal. All mouldings and trim shall be Douglas Fir, finger joint or approved

equal unless noted otherwise on plan.

4. All sheet metal flashing shall be installed in a workmanlike manner in compliance

with standard trade practices and the general contractor shall ensure a good

watertight job.

DIVISION 8 - DOORS WINDOWS AND GLASS: All interior doors shall be as specified on drawings.

All exterior doors shall be of the size shown on drawings and detailed by architect. Install all

doors and windows in accordance with recommendations of manufacturer complete with proper flashing

and anchoring.

1. All gypsum board and application and finishing standards as per ASTM C840 and

GA216.All gypsum board shall be thickness as shown on the drawings complete with

metal trim accesories as required. Edges of board shall be face tapered. Faces

of board shall be undamaged. Boards used to obtain fire rating shall comply with

fire code (and shall be clearly labled). Typical gypsum wallboard placement

(except shear walls) 1/2 " gypsum wallboard nailed with 6d cooler nails at 6" o.c. at

all edges and support edges may be unblocked. Stagger nails of adjacent sheet on

the same support.

2. Unless otherwise shown, lay tile in grid pattern. Align joints with

tiles on floor, base, walls and trim that are same size. Layout tile work and

center tile fields in both directions in each space or on each wall area. Adjust

to minimize tile cutting. Do not install tiles of less than one half normal size.

Provide uniform joint widths, unless otherwise shown. Consult and verify all tile

layout with architect prior to work.

3. Wall tile: Tile over gypsum wallboard, organic adhesive and latex/Portland cement

grout. Tile on interior floors with latex/Portland cement bond and coat grout.

DIVISION 16 - ELECTRICAL: Contractor shall comply with the latest applicable rules,

regulations, and specifications of the local laws and ordinances, State and Federal

laws, the National Electric Code, County Electrical Ordinances, the

State Fire Marshal, Underwriters Laboratories, Electric Safety Code and Life Safety Code.

Provide first quality, new materials free from defects, suitable for the space provided

and approved by the UL where standards have been provided by that agency.

Provide standard materials and equipment of manufacturer’s regularly engaged in the

production of these products. Provide products of a single manufacturer where two or

more units of the same class are required. Provide grounding and bonding per NEC.

All conductor ratings based on copper. All lighting fixtures, electrical devices,

ceiling fans, and so forth are to be provided by contractor. Contractor shall place a

service request with, and coordinate the installation of revenue meters with the

electrical utility company.

5. Provide T.V. outlets and cable as shown on plans.

10. All switches 48" to top from floor, except 42" at kitchen and bath counters.

13. Verify height of all exterior brackets prior to installation of wall material.

22

GENERAL NOTES

N/A

Page 3: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-03.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

207%%d30’00"

401.56

288%%

d45’40"162.5

5

34%%d37’00"

367.20

225%%d28’00"

300.01

45%%d28’00"

420.00

TRUE NORTH

151%

%d1

6’00

"

94.0

2

D/W

REF

TANK

W/H

VAC

SETBACK LINE

SETBACK LINE

30.00

’20.0

0

’20.0

0

’30.00

PROPOSED

NEW RESIDENCE

SITE PLANSCALE: 1"=20.00’

EXISTING

GATE

EXISTING

FENCE

’145.34

’20.2

5

’20.2

6

PAVED DRIVEWAY

EASEMENT 9-A

FOR ROAD & UTLITY

PURPOSES

WATER WELL

(BY OTHERS)

CESSPOOL

LOCATION

SITE PLAN

33

1"=20’

Page 4: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-04.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

110’-0"

88’-

0"

12’-

0"

32’-

0"

20’-

0"

24’-

0"

4’-0"52’-0"

13’-0"9’-0"4’-0"8’-0"18’-0"

ENTRYFOYER

MASTER BEDROOM

DINING

GREAT ROOM

STUDY

FLOOR PLAN (1ST FLOOR)

SCALE: 1/4"=1’-0"

LANAI

LIVING AREA

ENTRY AREA

LANAI AREA

GARAGE AREA

3,133 SQ FT

459 SQ FT

800 SQ FT

768 SQ FT

BEDROOM #2

288 SQ FTSHOP AREA

UP

13’-

0"

2’-

6"

8’-

6"

8’-

0"

10’-

4"

5’-

8"

7’-

8"

8’-

4"

D/W

LAUNDRY

OVEN

4’-0"9’-0"25’-0"14’-0"

ROOF LINE

ABOVE

BBQ

CLOSET

CLOSET

2’-0"

13’-0"

4’-0" 6’-0"

2 CAR

GARAGE

SHOP

TRACTOR

20’-

0"

4’-

0"

4’-

0"

6’-

0"

4’-

0"

28’-

0"

EXERCISE ROOM

BREEZEWAY

BUTLER’S

PANTRY

LANAI

44’-0"6’-0"4’-0"56’-0"

34’-0" 10’-0" 22’-0" 44’-0"

LANDING

LANDINGDOWN

DO

WN

+36" GUARDRAIL

(TYP)

128 SQ FTBREEZEWAY AREA

84’-

0"

14’-0" 20’-0"

18’-

0"

23’-

0"

24’-

0"

19’-

0"

12’-0"32’-0"

REF

10’-

0"

4’-

0"

10’-

0"

8

A

28’-

0"

8’-

6"

3’-

4"

6’-

2"

POWDER

LINEN

9’-0"5’-0"

KITCHEN

CLOSET

LANDING

6-0

X8-0

DB

L S

WIN

G

DO

OR

2-6

X4-6

DB

L H

UN

G

WIN

DO

W

5-0

X4-6

SL

IDIN

G

WIN

DO

W

6-0X4-6

SLIDING

WINDOW

5-0X5-6

SLIDING

WINDOW

2-6X4-6

DBL HUNG

WINDOW

10-0X8-0

(2) PANEL SLIDING

GLASS DOOR

2-8X8-0

SWING

DOOR

2-6X8-0

SWING

DOOR

2-6X8-0

SWING

DOOR

2-6

X8-0

PO

CK

ET

DO

OR

2-8X8-0

SWING

DOOR

2-6

X8-0

SW

ING

DO

OR

7-0X8-0

BYPASS

DOOR

5-4

X8-0

DB

L S

WIN

G

DO

OR

2-6

X8-0

SW

ING

DO

OR

2-0X8-0

SWING

DOOR

2-8

X8-0

SW

ING

DO

OR

2-8X8-0

SWING

DOOR

TANK

W/H

VAC

CLOSET

2-8

X8-0

SW

ING

DO

OR

18-0X8-0

(5) PANEL SECTIONAL

ROLL-UP DOOR

9-0X8-0

(5) PANEL SECTIONAL

ROLL-UP DOOR

4-0

X4-6

SL

IDIN

G

WIN

DO

W

4-0

X4-6

SL

IDIN

G

WIN

DO

W

4-0X4-6

SLIDING

WINDOW

4-0X4-6

SLIDING

WINDOW

4-0X4-6

SLIDING

WINDOW

2-8

X8-0

SW

ING

DO

OR

6-0

X4-6

SL

IDIN

G

WIN

DO

W

2-6

X6-8

SW

ING

DO

OR

2-8X8-0

SWING

DOOR

2-8X8-0

SWING

DOOR

2-8

X8-0

SW

ING

DO

OR

20

-0X

8-0

(4)

PA

NE

L S

LID

ING

GL

AS

S D

OO

R

12

-0X

8-0

(4)

PA

NE

L S

LID

ING

GL

AS

S D

OO

R

4-0

X4-6

SL

IDIN

G

WIN

DO

W

4-0

X4-6

SL

IDIN

G

WIN

DO

W

3-0

X4-6

DB

L H

UN

G

WIN

DO

W

20’-

0"

3-0X4-6

DBL HUNG

WINDOW

6-0

X5-0

SL

IDIN

G

WIN

DO

W

6-0X5-0

SLIDING

WINDOW

4-0X5-6 FIXED

O/ 4-0X1-6 JALOUSIE

WINDOW

4-0X

5-6

FIX

ED

O/ 4

-0X

1-6

JALO

USIE

WIN

DO

W

4-0

X5-6

FIX

ED

O/

4-0

X1-6

JA

LO

US

IE

WIN

DO

W

4-0X5-6 F

IXED

O/ 4-0X

1-6 JALO

USIE

WIN

DO

W

4’-0" 6’-0"

4-0X5-6 FIXED

O/ 4-0X1-6 JALOUSIE

WINDOW

4-0X1-6

SLIDING

WINDOW

SOLAR WATER

HEATING PANELS

ON ROOF ABOVE

8

B

2’-0"4’-0"9’-0"

2-8

X8-0

SW

ING

DO

OR

8

C

LA

ND

SC

AP

E -

PL

AN

TE

RL

AN

DS

CA

PE

- P

LA

NT

ER

5’-0"

6’-

0"

3’-

10"

8’-

2"

9’-0"7’-10"4’-2"4’-0"

4’-0" 9’-0"

2’-

8"

5’-

8"

2’-

0"

2’-

2"

3’-

4"

5’-

1"

5’-

5"

4’-

8"

12’-

0"

12’-

0"

11’-

5"

9’-

2"

11’-

5"

10’-0"6’-0"15’-0"1’-0"4’-0"

2-6

X4-6

SL

IDIN

G

WIN

DO

W

4’-0"

HANDRAIL

(TYP)

HANDRAIL

(TYP)

HANDRAIL

(TYP)

+36" GUARDRAIL

(TYP)

DOWN

CLOSET

VANITY W/

KNEE SPACE

BELOW

MASTER

BATH

2’-

6"

5’-

8"

CLOSET

2-6X8-0

SWING

DOOR

15’-2"5’-10"

44" HIGH WALL (TYP)

SINK

REFRIG

D/W

SIN

KSINK

RE

FR

IG

COOKTOP

SINKWASHER DRYER

SINK TOILET

TOILET

TUB/SHOWER

SINK

TUBTOILET

SIN

KS

INK

SHOWER

SOLAR STORAGE TANK

WATER HEATER

CENTRAL VACUUM

6’-

7"

10’-

10"

6’-

7"

8’-

4"

10’-

8"

CRM PLANTER

WALL (TYP)

WALL BELOW

4’-6"9’-6"

5’-0"

TO

ILE

TS

INK

SH

OW

ER

TOP OF GARAGE

WINDOWS @ 8’-0" A.F.F.

2-6X8-0

SWING

DOOR

BATH

#4

12’-0"25’-8"6’-4"

5’-0"18’-0"2’-8"

9’-

8"

20’-

0"

4’-

0"

4’-

0"

PRESSURE TANK

8-0

X5-0

(3)

PA

NE

L S

LID

ING

WIN

DO

W

HANDRAIL

4’-6" 3’-6"

2’-

0"

2’-2"

12’-

4"

5’-

8"

5’-0"

BATH #2

5’-5" 8’-9" 4’-0" 3’-8"

2’-

2"

11’-0"

+36" COUNTER

+36" COUNTER

+36" COUNTER

+36" COUNTER

+36" COUNTER

+36"

+36"

WALL BELOW

+36" C

OU

NT

ER

12"X12" COLUMN

(TYP)

12"X12" COLUMN

(TYP)

8’-0"12’-0"

2’-0"

2’-11"

+36"

+36"

+36"

44

1/4"=1’-0"

FLOOR PLAN

(1ST FLOOR)

Page 5: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-05.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

FLOOR PLAN (2ND FLOOR)

SCALE: 1/4"=1’-0"

88’-

0"

12’-

0"

32’-

0"

20’-

0"

24’-

0"

110’-0"

84’-

0"

60’-

0"

24’-

0"

BEDROOM #3

DO

WN

13’-

2"

10’-

10"

ROOF LINE

ABOVE

ROOF LINE

BELOW

LANAI

5’-4" 14’-8"

WALL / BEAM

LINE BELOW

14’-0" 20’-0" 10’-0" 22’-0" 44’-0"

20’-

0"

4’-

0"

10’-

0"

14’-

0"

44’-0"6’-0"4’-0"56’-0"

14’-8"5’-4"

20’-0"

+36"

GUARDRAIL

(TYP)

BATH

#3

8

A

STAIRS

132" RISE (TOTAL)

(18) 7 1/3" RISERS

10

-0X

7-6

(2)

PA

NE

L S

LID

ING

GL

AS

S D

OO

R

6-0X4-6

SLIDING

WINDOW

3-0

X4-6

DB

L H

UN

G

WIN

DO

W

3-0

X4-6

DB

L H

UN

G

WIN

DO

W

3-0

X4-6

DB

L H

UN

G

WIN

DO

W

2-6

X2-6

DB

L H

UN

G

WIN

DO

W

8-0X7-6

BYPASS

DOOR

8

B

LIVING AREA 410 SQ FT

LANAI AREA 70 SQ FT

8

C

HANDRAIL

+36"

CLOSET

2’-

5"

8’-

8"

3’-

0"

4’-

0"

2’-

10"

4’-0"

2-8

X7-6

SW

ING

DO

OR

10’-8"

55

1/4"=1’-0"

FLOOR PLAN

(2ND FLOOR)

Page 6: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-06.dgn 11/19/2013

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

P13-026PJP

15

11/18/2013

66

1/4"=1’-0"

EXTERIOR ELEVATIONS

FRONT ELEVATIONSCALE: 1/4"=1’-0"

LEFT ELEVATIONSCALE: 1/4"=1’-0"

SEAMLESS ALUMINUM

RAIN GUTTER (TYP)

WOOD FASCIA (TYP)

1X4 TRIM (TYP)

1X4 TRIM (TYP)

T1-11 SIDING

NO GROOVES (TYP)

2X10 BAND (TYP)

1X3 BATTENS (TYP)

METAL ROOFING (TYP)

1X4 SKIRTING (TYP)

Page 7: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-07.dgn 11/19/2013

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

P13-026PJP

15

11/18/2013

77

1/4"=1’-0"

EXTERIOR ELEVATIONS

RIGHT ELEVATIONSCALE: 1/4"=1’-0"

REAR ELEVATIONSCALE: 1/4"=1’-0"

Page 8: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-08.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

A

8

SECTIONSCALE: 1/4"=1’-0"

GREAT ROOMLANAI FOYER ENTRY

2’-

0"

3’-

0"

10’-

0"

5’-

0"

1’-

0"

PLANTER

B

8

SECTIONSCALE: 1/4"=1’-0"

LANAI

BREEZEWAY GARAGE WORKSHOP

EXERCISE ROOM

9’-

4"

12’-

6"

BEDROOM #3LANAI

PLANTER

1’-

0"

1’-

0"

10’-

0"

C

8

SECTIONSCALE: 1/4"=1’-0"

GREAT ROOM

10’-

0" MASTER

TOILET

MASTER

CLOSETHALL KITCHEN

ST

AIR

WE

LL

EXERCISE ROOM

BEDROOM #3

12’-

0"

10’-

0"

9’-

4"

2’-

0"

10’-

0"

88

1/4"=1’-0"

SECTIONS

Page 9: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-09.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

D/W

REF

TANK

W/H

VAC

8

A

5/1

2

5/12

5/1

2

OPEN STAIRWELL

SL

OP

E

HORIZONTAL

CEILING @ 12’-6"

HORIZONTAL

CEILING @ 12’-6"

HORIZONTAL

CEILING @ 12’-6"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

10’-0"

10’-0"

10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

COFFERED

CEILING @ 11’-0"

REFLECTED CEILING PLAN (1ST FLOOR)

SCALE: 1/4"=1’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

HORIZONTAL

CEILING @ 10’-0"

2’-

0"

2’-

0"

2’-0"2’-0"

5/12

5/1

2

5/12

2’-0"

3’-

6"

3’-

6"

3’-

6"

2’-0"

3’-

6"

2’-0"2’-0"

EXHAUST

FAN

8

B

5/1

2

5/1

2

5/12

5/12

5/12

5/1

2

5/1

2

5/12

5/12

5/1

2

5/1

2

5/12

5/12

5/12

5/1

2

5/1

2

5/12

5/12

5/1

2

5/12

5/12

HORIZONTAL

CEILING @ 10’-0"

5/12

COFFERED

CEILING

@ 11’-0"

COFFERED

CEILING

@ 11’-0"

SO

FF

IT @

8’-

4"

SO

FF

IT @

8’-

4"

8

C

HORIZONTAL EAVE (TYP)

HORIZONTAL EAVE (TYP)

HORIZONTAL EAVE (TYP)

HORIZONTAL EAVE (TYP)

HO

RIZ

ON

TA

L E

AV

E (

TY

P)

HO

RIZ

ON

TA

L E

AV

E (

TY

P)

COFFERED

CEILING

@ 11’-0"

10’-0"

R

RR

R

R

R

R R

R

R

R

R

R

R RR

R

R R

R

R

R

RR

R

R

R

R

RR

R R

RR

R

R

R

R

RR

R

R R R R

R RR

R

R

R R

R

R

R

RR

RR

R

RR

R R

RR

R R

RR

R R

R

R

R

R

S

S

S

SS

SS S

S SS

R

R

R

R

R

R

RR

R

R

R R

10’-0"

SD

SD

SD

SD

SD

SD

R

R

RR

R

FL

FL

FLPP

R

R R

R

R R

SD

R R

R R

R R

R

P

P

P

RR

FL

HORIZONTAL

CEILING @ 12’-6"

EXHAUST

FAN

S

HORIZONTAL

CEILING @ 12’-6"

FL

R

2X6 WALL

HORIZONTAL

CEILING @ 9’-0"

2ND FLOOR

HORIZONTAL

CEILING @ 9’-0"

HORIZONTAL

CEILING @ 9’-0"

HORIZONTAL

CEILING @ 9’-0"

HORIZONTAL

CEILING @ 9’-0"

COFFERED

CEILING @ 9’-6"

EXHAUST

FAN

2’-

0"

2’-0"2’-0"

2’-

0"

8

BB

5/12

5/12

5/1

2

5/1

2

SO

FF

IT @

7’-

7"

8

C

SD

RR

R

R

R

R

R

R

R

ATTIC

ACCESS

FL

HORIZONTAL EAVE (TYP)

99

1/4"=1’-0"

REFLECTED CEILING PLAN

Page 10: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-10.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

OPEN TO 2ND FLOOR

5/1

2

5/12

5/1

2

5/12

5/1

2

5/12

5/12

5/1

2

5/12

5/12

5/1

2

5/1

2

5/12

5/1

2

CR

ICK

ET

5/1

2

5/1

2

5/12

5/12

5/1

2

5/1

2

5/12

5/12

WA

LL

LIN

E B

EL

OW

WALL LINE BELOW

WA

LL

LIN

E B

EL

OW

ROOF PLANSCALE: 1/4"=1’-0"

(1ST FLOOR)

3’-6"

3’-

6"

3’-

6"

3’-

6"

3’-

6"

3’-6"

8

A

8

B

8

C

5/12

5/1

2

5/1

2

5/12

WA

LL

LIN

E B

EL

OW

3’-0"

8

B

8

C

3’-0"

3’-

0"

3’-

0"

2ND FLOOR

1010

1/4"=1’-0"

ROOF PLAN

Page 11: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-11.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

9’-

0"

9’-

0"

9’-

2"

9’-

2"

9’-

2"

9’-

2"

9’-

4"

FOUNDATION PLANSCALE: 1/4"=1’-0"

34’-0" 10’-0" 22’-0" 44’-0"

24’-

0"

20’-

0"

32’-

0"

12’-

0"

44’-0"6’-0"4’-0"56’-0"

84’-

0"

18’-

0"

66’-

0"

4’-

0"

5’-

0"

5’-

0"

4’-

0"

29’-

7"

10’-

10"

14

’-1

1"

10’-

8"

7’-

8"

7’-

8"

7’-

8"

8’-

0"

8’-

0"

8’-

0"

7’-

6"

7’-

6"

4’-

0"

14’-0" 20’-0"

4’-0" 3’-0" 7’-0" 10’-0" 6’-0" 4’-0" 4’-0" 5’-0" 1’-0"

4’-0" 3’-0" 7’-0" 10’-0" 10’-0" 9’-0" 5’-0" 4’-0" 4’-0"

5’-0" 4’-0"

4’-0" 4’-0" 6’-0"

4’-

0"

6’-

0"

4’-

0"

9’-

0"

9’-

0"

8’-

5"

8’-

5"

8’-

5"

8’-

5"

8’-

4"

4’-

0"

6’-

8"

6’-

8"

6’-

8"

4’-

0"

6’-

6"

6’-

6"

7’-

0"

6’-

0"

5’-

0"

7’-

0"

4’-

0"

3’-

10"

6’-

6"

5’-

8"

4’-

0"

8’-

4"

8’-

4"

8’-

4"

8’-

4"

8’-

4"

8’-

4"

8’-

4"

7’-

8"

7’-

10"

5’-

5"

5’-

6"

5’-

2"

8’-

2"

5’-

4"

5’-

7"

5’-

7"

5’-

7"

4’-0"

10"

6’-

4"

10"

4’-

0"

6’-

10"

6’-

11"

6’-

10"

6’-

11"

6’-

10"

4’-

0"

5’-

10"

6’-

0"

5’-

10"

4’-

0"

6’-0"4’-0"3’-0"

18’-0"4’-0"

4’-

0"

6’-

0"

6’-

0"

4’-

0"

10’-

0"

4’-

0"

6’-

6"

3’-

6"

9’-

6"

5’-

0"

9’-

6"

5’-0"

10’-

8"

10’-

8"

10’-

8"

10’-

0"

10’-

0"

1’-6"9’-4"6’-0"18’-4"8’-10"

5’-4"

5’-6"

5’-0"

HD

5B

HD

5B

HD

5BH

D5B

HD

5B

HD

5B

HD

5BH

D5B

HD

5BH

D5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

4’-0"3’-0"3’-0"4’-0"

5’-0"

4’-0" 4’-0" 6’-0"

2’-0"2’-0"

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5BH

D5B

HD

5BH

D5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

HD

5B

CB46

CB46

CB46 C

B46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46 C

B46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB

46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB46

CB66

CB66

FMHA PIER BLK

W/ EMBEDDED METAL

STRAP (TYP OF 2)

SLOPE 1%

SLOPE 1%

SL

OP

E 1

%

6" WIDE CURB

(TYP)

16"X12" FOOTING

W/ (2) #4 REBAR CONT

& #3 TIES @ 24" O.C.

(TYP)

16"X12" FOOTING

W/ (2) #4 REBAR CONT

& #3 TIES @ 24" O.C.

HD

5B

4" THK CONC SLAB

W/ #3 REBAR B.W.

@ 18" O.C.

4" THK CONC SLAB

W/ #3 REBAR B.W.

@ 18" O.C.

CRM PLANTER

WALL (TYP)

NOTES

1. ALL SLABS & FOOTINGS SHALL BEAR UPON

COMPETENT BEARING MATERIAL.

2. FOR HD5B’S AT 12" DEEP FOOTINGS, USE

5/8"Ø THREADED ROD 10" DEEP W/ EPOXY

PER SIMPSON REQUIREMENTS.

24’ W X 12" D FOOTING

W/ #4 REBAR

@ 10" O.C. - B.W. (TYP)

24"X24"X12" FOOTING

W/ (3) #4 REBAR B.W.

(TYP)

24’ W X 12" D FOOTING

W/ #4 REBAR

@ 10" O.C. - B.W. (TYP)

12

1

12

1

12

1

12

1

12

2

12

3

24"X24"X12" FOOTING

W/ (3) #4 REBAR B.W.

(TYP)

HD

5B

HD

5BH

D5B

HD

5BH

D5B

HD

5B

HD

5B

HD

5BH

D5B

12

5

12

5

12

5

12

5

12

4

12

4

12

5

SIMILAR

16"X12" FOOTING

W/ (2) #4 REBAR CONT

& #3 TIES @ 24" O.C.

1111

1/4"=1’-0"

FOUNDATION PLAN

Page 12: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-12.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

4’-0"4’-0"9’-0"9’-0"10’-0"10’-0"7’-0"7’-0"

56’-0" 4’-0"

20’-

0"

20’-

0"

32’-

0"

12’-

0"

34’-0" 22’-0" 4’-0"

84’-

0"

FLOOR FRAMING PLANSCALE: 1/4"=1’-0"

2X10 FLOOR JOISTS

@ 16" O.C. (TYP)

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X6

P

ECC46 4X

6 P

ECC46

4X4

P

4X4

P

4X4

P

4X4 P

4X4 P

4X4 P

2X

10 R

IM J

OIS

T &

BL

KG

CC464X

6 P

CC464X

6 P

4X6

P

ECC46

4X

12

BE

AM

CC464X

6 P

CC464X

6 P

4X

12

BE

AM

CC464X

6 P

DBL JOIST

4X6

P

ECC46

4X

12

BE

AM

CC464X

6 P

CC464X

6 P

4X

12

BE

AM

4X6

P

ECC46

4X

12

BE

AM

CC464X

6 P

CC464X

6 P

4X

12

BE

AM

4X6

P

ECC46

4X6

P

ECC46

4X4 P

4X4 P

4X4 P

4X4

P

4X4

P

4X4

P

4X4

P

4X6 P

ECC46

4X6 P

ECC46

CC464X

6 P

CC464X

6 P

4’-0"5’-0"

CC464X

6 P

4X6 P

ECC46

4X

8 B

EA

M

CC46

4X6 P

CC46

4X6 P

4X6

P

ECC46

11’-

1"

9’-

10"

11’-

1"

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

HU

C48

HU

C48

HU

C48

4X12 STRINGER

(TYP OF 3)

4X12 TREADS

W/ TA10 BOTH ENDS

(TYP)

HL33

HL33

HL33

FASTEN STRINGERS

TO LANDING W/ HL33

(TYP)

NOTES

1.

2.

5.

3. PROVIDE DOUBLE FLOOR JOISTS UNDER

PARALLEL PARTITION WALLS ABOVE.

4. PROVIDE DOUBLE SOLID BLOCKING UNDER PARTITION

WALLS ABOVE PERPENDICULAR TO FLOOR JOISTS.

FLOOR SHEATHING SHALL BE FASTENED W/

10d NAILS @ 4" O.C. BOUNDARIES, 6" O.C. EDGES

& 8" O.C. FIELD.

PROVIDE SOLID BLOCKING ABOVE ALL BEAMS.

6. ALL PERIMETER POSTS TO BE BRACED W/ 4X4’S

& 1/2"Ø LAG BOLTS BOTH ENDS.

ALL GLUE LAM BEAMS SHALL BE COMBINATION

24F & CAMBER = 1600’ RADIUS.

DBL JOIST

DBL JOIST

CC46

4X6 P

CC46

4X6 P

CC46

4X6 P

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X6

P

ECC46

4X6

P

ECC46

CC46

4X6 P

4X

8 B

EA

M4X

8 B

EA

M

2X

10 R

IM J

OIS

T &

BL

KG

2X

10 R

IM J

OIS

T &

BL

KG

2X

10 R

IM J

OIS

T &

BL

KG

2X

10 R

IM J

OIS

T &

BL

KG

4X4

P

4X4

P

4X4

P

4X6

P

ECC46

4X4 P

4X4 P

4X12 TREADS

W/ TA10 BOTH ENDS

(TYP)

HU

C48

HU

C48

3’-

6"

4X12 STRINGER

(TYP OF 3)

HL33

HL33

10’-0" 4’-0" 8’-0"

4X6 BM

LU

26

EPC44

4X4 P

4X4

P

EPC44

LU

26-2

LU

26-2

2X6 JOISTS @ 16" O.C.

DB

L

DB

L

DBL JOIST

DBL JOIST

DBL JOIST

CC46

4X6 P

CC46

4X6 P

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

4X6

P

ECC46

4X6

P

ECC46

4X6

P

ECC46

4X6

P

ECC46

4X6

P

ECC46

4X

12 B

EA

M C

ON

T4X

12 B

EA

M C

ON

T

CC46

4X6 P

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC46

4X6 P

CC46

4X6 P

4X10 JOIST4X10 JOIST

CC464X

6 P

4X

10 B

EA

M C

ON

T

4X

12 B

EA

M C

ON

T

4X

12 B

EA

M C

ON

T

CC464X

6 P

4X

12 B

EA

M C

ON

T4

X1

2 B

EA

M

CC464X

6 P

4X

12

BE

AM

CC464X

6 P

4X

12

BE

AM

CC464X

6 P

4X

12

BE

AM

CC464X

6 P

CC464X

6 P

CC464X

6 P

4X4 P

4X4 P

4X4 P

4X4

P

4X4

P

4X4

P

4X

12 B

EA

M C

ON

T

4X4 P

4X4 P

4X4 P4X

4 P

CC46

4X6 P

4X4

P

4X6

P

ECC46

CC464X

6 P

CC464X

6 P

4X4

P

4X4

P

4X4

P

CC464X

6 P

CC46

4X6 P

4X4 P

4X4 P

4X4 P

4X4 P

4X4 P

4X4 P

4X6 P

ECC46

TRIPPLE JOIST

DBL JOISTTRIPPLE JOIST

TRIPPLE JOIST

2X

10 R

IM J

OIS

T &

BL

KG

2X

10 R

IM J

OIS

T &

BL

KG

2X

10 R

IM J

OIS

T &

BL

KG

HL33

HU

C48

FASTEN STRINGERS

TO LANDING W/ HL33

(TYP)

4X12 STRINGER

(TYP OF 3)

HU

C48

HL33

HU

C48

HL33

26’-

0"

10’-

0"

48’-

0"

4X12 TREADS

W/ TA10 BOTH

ENDS (TYP)

4X6

P

ECC46

4X6 P

ECC46

4X

10

BE

AM

DBL JOIST

DBL JOIST

2X10 FLOOR JOISTS

@ 16" O.C. (TYP)

@ 16" O.C. (TYP)

2X10 FLOOR JOISTS

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

TRIPPLE JOIST

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

CC464X

6 P

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

4X

10

BE

AM

CC464X

6 P

CC464X

6 P

4X

10 B

EA

M C

ON

T

4X

12

BE

AM

4X

12

BE

AM

4X

12

BE

AM

4X

12 B

EA

M C

ON

T

DBL JOIST

DBL JOIST

MID

-SP

AN

BL

KG

MID

-SP

AN

BL

KG

MID

-SP

AN

BL

KG

MID

-SP

AN

BL

KG

DBL JOIST

DBL JOIST

DBL JOIST

DBL JOIST

DBL JOIST

DBL JOIST

DBL JOIST

DBL JOIST

DBL JOIST

14

1

14

2

14

7

14

3

14

4

14

3

SIMILAR

14

4

SIMILAR

14

8

14

8

12

5

5

5

12

12

5

5

12

12

(2) #4 REBAR CONT.

& #3 TIES @ 24" O.C.

SLAB REINFORCING

PER PLAN

1/2"X10" A.B. @ 48" O.C.

& 6" FROM PLT ENDS U.N.O.

DETAILSCALE: 1"=1’-0"

3"

12"

16"

6"

BOTTOM PLT

F.G.

V

AR

IES

SCALE 1"=1’-0"

DETAIL

2X4 BOTTOM PLT

(2) #4 REBAR CONT.

& #3 TIES @ 24" O.C.

1/2"X10" A.B.

@ 48" O.C. U.N.O.

"16

"1

2

"3

A35F @ 12" O.C.

1/2" CDX PLYWOOD

O/ 2X4 STUDS @ 16" O.C.

H.D. PER PLAN

DETAILSCALE: 1"=1’-0"

F.G.

3"

2"

(3) #4 REBAR CONT

& #3 TIES @ 12" O.C.

(2) #4 REBAR CONT

& #3 TIES @ 12" O.C.

3/4"Ø EPOXY ANCHOR

ASTM-A307

9" MIN EMBEDMENT

24"

12"

(2) 2X4 PLTS

POST BEYOND

PER PLAN

NOTE:

FASTEN PLYWOOD WALL SHEATHING

W/ 8d NAILS @ 4" O.C. BOUNDARIES,

6" O.C. EDGES & 8" O.C. FIELD.

2X4 PLATE

RIM JOIST & BLKG

1/2" CDX PLYWOOD OR

5/8" T1-11 SIDING

ST6224 POSTS TO

RIM JOIST

FOOTING

CB

POST

F.G.

SCALE: 1"=1’-0"

DETAIL

"1

2

3"

5/8"Ø M.B. (TYP)

PER PLAN

#4 REBAR @ 10" O.C.

BOTH WAYS

1

12

2

12

3

12

5

12

FOOTING

F.G.

SCALE: 1"=1’-0"

DETAIL

3"

5/8"Ø M.B. (TYP)

PER PLAN

#4 REBAR @ 10" O.C.

BOTH WAYSF.G.

MIN

CB PER PLAN

POST PER PLAN

20"

12"

6"

4

12

1212

1/4"=1’-0"

FLOOR FRAMING PLAN

Page 13: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-13.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

ROOF FRAMING PLANSCALE: 1/4"=1’-0"

HIP

TRU

SS

HIP

TRU

SS

HIP

TRU

SS

HIP

TRU

SS

HIP

TRU

SS

2X6 H

IP BLK

G

2X6 RIDGE BLKG

2X6

VA

LLEY

BLK

G

2X6

HIP

BLK

G2X

6 HIP B

LK

G

2X6

HIP

BLK

G

2X

6 H

IP B

LK

G

2X6

HIP

BLK

G

2X6

HIP

BLK

G2X

6 HIP B

LK

G

2X6

HIP

BLK

G

2X6 H

IP BLK

G

2X6 V

ALLEY

2X6

VA

LLEY

HIP

TRU

SS

2X6 V

ALLEY

BLK

G

BLK

G

2X6 V

ALLEY

2X6

VA

LLEY

2X6 RIDGE BLKG

BLK

GBLK

G2

X6

RID

GE

BL

KG

2X

6 R

IDG

E B

LK

G

2X

6 R

IDG

E B

LK

G

HCP2

6X6

P

6X6

P

6X6 P

6X6 P

HCP2

4X6 T

RM

R

4X6 T

RM

R4X

6 TRM

R

2X8 FASCIA

4X6

TRM

R

HCP2

6X6

P

6X6 P

6X6 HDR6X6 HDR6X6 HDR

2X8 FASCIA

ST6236

ST6236

ST6236

2X8 FASCIA

2X8 FASCIA

6X6

P

HCP2

6X6

P

2X

6 R

IDG

E B

LK

G

4X6 HDR

4X

6 P2X

6 V

ALLEY

6X6 P

2X6

VA

LLEY

BLK

G

2X6 V

ALLEY

BLK

G

6X6 P 2X

6 V

ALLEY

6X6 P

HCP2

6X6 P

6X6 P

6X6

P

HCP2

2X

8 F

AS

CIA

6X6

P

6X6

P

HCP2

ST62

36H

CP2

2X6 V

ALLEY

BLK

G

DBL T

RM

R

DBL T

RM

R

4X6

P

6X6

P

6X6

P

6X6

P

2X

8 F

AS

CIA

2X6 V

ALLEY

4X6

P4X8 HDR

4X6

P

4X6 HDR4X6 HDR4X6 HDR

2X8 FASCIA

4X6

P

ST62

36

4X6

TRM

R

4X6 T

RM

R

4X6 HDR

4X6 HDR

2X6 H

IP BLK

G

4X

6 H

DR

4X

6 H

DR

HIP

TRU

SS

4X

6 H

DR

HCP2

2X12 FLOOR JOISTS @ 16" O.C. (TYP)

5 1

/8" X

15

" G

.L.B

.

5 1/8" X 15" G.L.B.

G.L.B.

5 1/8" X 15"

5 1

/8" X

15

" G

.L.B

.5

1/8

" X

15

" G

.L.B

.5

1/8

" X

15

" G

.L.B

.

5 1/8" X 15"

G.L.B.

5 1

/8" X

15

" G

.L.B

.

5 1/8" X 15" G.L.B.

ECCL

ECCL

ECCL

ECCL

ECCL

ECCL

ECCL

ECCL

ECCL

CC

CC

CC

CC

5 1

/8" X

16 1

/2" G

.L.B

.5 1

/8" X

16 1

/2" G

.L.B

.5 1

/8" X

16 1

/2" G

.L.B

.

G.L.B.

5 1/8" X 16 1/2"

5 1

/8" X

19

1/2

" G

.L.

HD

R

4X4

P4X

6 P

4X10 BEAM

H2.5(T

YP)

H2.5(T

YP)

4X10 HDR

DBL T

RM

R

DBL T

RM

R

4X

14

HD

R

4X

8 H

DR

DBL S

TU

DD

BL S

TU

DD

BL S

TU

DD

BL S

TU

D

4X4

P

4X4

P

4X12

HD

R

4X

8 H

DR

4X6 H

DR

DBL TRMR

DB

L T

RM

R

6X

6 H

DR

4X

10

HD

R

4X

12

HD

R

4X

10

HD

R4

X4

HD

R

4X

6 H

DR

4X

6 H

DR

4X

4 H

DR

4X6 HDR

6X10 HDR

5 1/8" X 12" G.L.B.

5 1/8" X 12" G.L.B.

5 1

/8" X

12

" G

.L.B

.

5 1

/8" X

12

" G

.L.B

.

3 1

/8" X

16

1/2

" G

.L.

HD

R

4X4 T

RM

R

4X4

TRM

R

4X10 HDR

4X

12

HD

R

DBL T

RM

R

DBL T

RM

R

ST6236

ST62

36

ST6236

ST62

36

H2.

5

(TY

P)

H2.5

(TY

P)

H2 @ 48" O.C. TO ALIGN W/

STUDS & H2.5 ALTERNATING

AT EVERY OTHER RAFTER

AT ALL PERIMETER WALLS

(TYP)

H2 @ 48" O.C. TO ALIGN W/

STUDS & H2.5 ALTERNATING

AT EVERY OTHER RAFTER

AT ALL PERIMETER WALLS

(TYP)

ST6236

ST62

36

ST6236S

T62

36

ST62

36

ST62

36

ST6236

ST6236

HIP

TRU

SS

2X6 JACK RAFTER

(TYP)

3’-6"

3’-

6"

3’-6"

3’-

6"

3’-

6"

3’-

6"

3’-

6"

3’-

6"

3’-6"

3’-

6"

3’-6"

3’-6"

HCP2 H

CP2

HCP2

22"X30" ATTIC

ACCESS

22"X30" ATTIC

ACCESS

22"X30" ATTIC

ACCESS

SL

OP

E

CALIFORNIA

FRAMING

NOTES

1.

2.

3. PROVIDE DOUBLE TRIMMERS AT OPENINGS 8’

AND WIDER U.N.O.

ROOF SHEATHING SHALL BE FASTENED W/ 8d

NAILS @ 4" O.C. BOUNDARIES, 6" O.C. EDGES

& 8" O.C. FIELD.

ALL GLUE LAM BEAMS SHALL BE COMBINATION

24F & CAMBER = 1600’ RADIUS.

4. INSTALL ALL TRUSS HARDWARE PER TRUSS

MANUFACTURER’S SPECIFICATIONS.

SW1

SHEAR WALLS

1/2" CDX PLYWOOD - NAILING SAME AS

EXTERIOR.

SW1SW1SW1SW1SW1

1

14

14

2

14

3

14

4

5 1/8" X 16 1/2" G.L. HDR

HIP

TRU

SS

HIP

TRU

SS

HIP

TRU

SS

HIP

TRU

SS

HIP

TRU

SS 4

X6

HD

R

14

5

14

6

14

7

8’-0"

2X

12 B

LK

G

2X

12 B

LK

G

ENGINEERED TRUSSES

@ 24" O.C. (TYP

(2) 2X12 JOISTS

(2) 2X12 JOISTS

(2) 2X12

JOISTS

U210 2X12 STRINGER (TYP OF 3)

2X12 STRINGER (TYP OF 3)

4X6 HDR

4X4

P

4

14

SIMILAR

4X4 P

4X

8 B

M

4X

8 B

M

U26

U28

2X6 JOISTS

@ 16" O.C.

4X4

P

4X4 P

DBL 2X4 HDR @ INTERIOR

OPENINGS (TYP U.N.O.)

DBL 2X4 HDR @ INTERIOR

OPENINGS (TYP U.N.O.)

DBL 2X4 HDR @ INTERIOR

OPENINGS (TYP U.N.O.)

STUDS

TOP PLTS

BOT CORD

A35 @ 24" O.C.

BLKG

DETAILSCALE 1"=1’-0"

DETAILSCALE 1"=1’-0"

BOT CORD

A35 @ 24" O.C.

TOP PLTS

STUDS

BLKG

A35 @ 24" 0.C.

BLKG @ 24" O.C.

BOT CORD

(TYP)

TOP PLTS

STUDS

DETAILSCALE 1"=1’-0"

2X4 FRAME

(TYP)

TOP CORD (TYP)

3/8" CDX PLYWOOD

BOT CORD (TYP)

DETAILSCALE 1/2"=1’-0"

13

2

13

2

4

13

13

1

1

13

2

13

3

13

4

13

13

2

13

1

13

3

13

1

13

1

13

2

13

3

13

1

13

1

13

1

13

2

EN

GIN

EE

RE

S T

RU

SS

ES

@ 2

4" O

.C. (T

YP

)

ENGINEERED TRUSSES @ 24" O.C. (TYP)

(2ND FLOOR)

2X8 FASCIA

2X

8 F

AS

CIA

2X8 FASCIA

2X

8 F

AS

CIA

HIP

TRU

SS

HIP

TRU

SS

HIP

TRU

SS

HIP

TRU

SS

BLK

GBLK

G

BLK

GBLK

G

2X

6 B

LK

G

3’-

0"

3 1

/8" X

12

" G

.L.B

.

3 1/8" X 12" G.L.B. 4X8 HDR

4X

10

HD

R

4X

6 H

DR

4X

6 H

DR

4X

6 H

DR

4X

6 H

DR

4X4 P

4X4 P

4X4

P

HCP2

HCP2 H

CP2

HCP2

DBL T

RM

R

DBL T

RM

R

ST62

36

ST62

36

ECCL

22"X30" ATTIC

ACCESS

14

7

13

3

13

1

ENGINEERED TRUSSES @ 24" O.C. (TYP)

H2.

5

(TY

P)

H2 @ 48" O.C. TO ALIGN W/

STUDS & H2.5 ALTERNATING

AT EVERY OTHER RAFTER

AT ALL PERIMETER WALLS

(TYP)

1313

1/4"=1’-0"

ROOF FRAMING PLANS

Page 14: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-14.dgn 11/19/2013

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

10’-

0"

FASCIA PER PLAN

SEAMLESS ALUM GUTTER

DRIP EDGE FLASHING

(2) 2X4 TOP PLTS

2X6 BLKG W/ (2) 2"Ø

VENT HOLES EACH BLK

H2’S & H2.5’S PER PLAN

METAL ROOFING

O/ WATERPROFF MEMBRANE

O/ 5/8" CDX PLYWOOD

O/ ENGINEERED TRUSSES PER PLAN

CONTINUOUS SOFFIT VENT

1X3 TRIM (TYP)

2X4 CONT

5/8" T1-11 PLAIN SIDING

NO GROOVES

O/ TYVEK HOUSEWRAP OR EQUAL

O/ 2X4 STUDS @ 16" O.C.

NOTE:

FASTEN PLYWOOD WALL SHEATHING

W/ 8d NAILS @ 4" O.C. BOUNDARIES,

6" O.C. EDGES & 8" O.C. FIELD.

3/4" T&G PLYWOOD

O/ FLOOR JOISTS

PER PLAN

2X6 CLEAT

2X4 BRACING

(2) 2X4 TOP PLTS

CS20X34" STUD TO BEAM

TO ALIGN WITH RAFTERS

@ 48" O.C.

1/2" GYP BRD

5/8" GYP BRD

2X10 BOTTOM BAND

RIM JOIST & BLKG PER PLAN

BEAM PER PLAN

POST BEYOND PER PLAN

1X4 SKIRTING

FOOTING BEYOND PER PLAN

FINISH GRADE

1

14

SECTIONSCALE: 1/2"=1’-0"

WINDOW PER PLAN

DBL 2X4 SILL

HEADER PER PLAN

1X4 TRIM (TYP)

5/8" SOFFIT BRD

O/ 2X4’S @ 24" O.C.

FASCIA PER PLAN

SEAMLESS ALUM GUTTER

DRIP EDGE FLASHING

(2) 2X4 TOP PLTS

2X6 BLKG W/ (2) 2"Ø

VENT HOLES EACH BLK

H2’S & H2.5’S PER PLAN

METAL ROOFING

O/ WATERPROFF MEMBRANE

O/ 5/8" CDX PLYWOOD

O/ ENGINEERED TRUSSES PER PLAN

CONTINUOUS SOFFIT VENT

1X3 TRIM (TYP)

2X4 CONT

5/8" T1-11 PLAIN SIDING

NO GROOVES

O/ TYVEK HOUSEWRAP OR EQUAL

O/ 2X4 STUDS @ 16" O.C.

NOTE:

FASTEN PLYWOOD WALL SHEATHING

W/ 8d NAILS @ 4" O.C. BOUNDARIES,

6" O.C. EDGES & 8" O.C. FIELD.

3/4" T&G PLYWOOD

O/ FLOOR JOISTS

PER PLAN

2X4 BRACING

(2) 2X4 TOP PLTS

1/2" GYP BRD

5/8" GYP BRD

2X10 BOTTOM BAND

POST BEYOND PER PLAN

1X4 SKIRTING

FOOTING BEYOND PER PLAN

FINISH GRADE

2

14

SECTIONSCALE: 1/2"=1’-0"

CS20X22" STUD TO RIM JOIST

TO ALIGN WITH RAFTERS

@ 48" O.C.

RIM JOISTS PER PLAN

CC PER PLAN

BEAM BEYOND

PER PLAN

10’-

0"

5/8" SOFFIT BRD

O/ 2X4’S @ 24" O.C.

FASCIA PER PLAN

SEAMLESS ALUM GUTTER

DRIP EDGE FLASHING

2X6 BLKG W/ (2) 2"Ø

VENT HOLES EACH BLK

METAL ROOFING

O/ WATERPROFF MEMBRANE

O/ 5/8" CDX PLYWOOD

O/ ENGINEERED TRUSSES PER PLAN

CONTINUOUS SOFFIT VENT

1X3 TRIM (TYP)

2X4 CONT

3/4" T&G PLYWOOD

O/ FLOOR JOISTS

PER PLAN

1/2" GYP BRD

5/8" GYP BRD

2X10 BOTTOM BAND

RIM JOIST & BLKG PER PLAN

1X4 SKIRTING

FOOTING BEYOND PER PLANFINISH GRADE

3

14

SECTIONSCALE: 1/2"=1’-0"

10’-

0"

CS20X34" STUD TO

BEAM -TO ALIGN WITH

RAFTERS @ 48" O.C.

WINDOW PER PLAN

HEADER PER PLAN

1X TRIM (TYP)

COLUMN BEYOND

5/8" SOFFIT BRD

O/ 2X4’S @ 24" O.C.

2X4 BLKG

2X4 BOTTOM RAIL

2X6 TOP RAIL

2X2 PICKETS

MAX 4" SPACING

CS20X34" POST TO

BEAM BELOW

DBL 2X4 SILL

POST BEYOND PER PLAN (TYP)

BEAM PER PLAN (TYP)2X6 CLEAT

(TYP)

2X4 BRACING

(TYP)

5/8" T1-11 PLAIN SIDING

NO GROOVES

O/ TYVEK HOUSEWRAP

O/ 2X4 STUDS @ 16" O.C.

3’-

0"

MIN

2X4 BOTTOM PLT

PLANK DECKING

2X BLKG (TYP)

5/8" SOFFIT BRD

POST PER PLAN

IN COLUMN BEYOND

5/8" T1-11 PLAIN

SIDING O/ 2X4’S

@ 24" O.C.

(2) 2X4 TOP PLTS

24

" M

IN

BEAM PER PLAN

H2.5’S PER PLAN

FASCIA PER PLAN

SEAMLESS ALUM GUTTER

DRIP EDGE FLASHING

2X6 BLKG W/ (2) 2"Ø

VENT HOLES EACH BLK

METAL ROOFING

O/ WATERPROFF MEMBRANE

O/ 5/8" CDX PLYWOOD

O/ ENGINEERED TRUSSES PER PLAN

CONTINUOUS SOFFIT VENT

1X3 TRIM (TYP)

2X4 CONT

FINISH GRADE

4

14

SECTIONSCALE: 1/2"=1’-0"

1X TRIM (TYP)

COLUMN BEYOND

5/8" SOFFIT BRD

O/ 2X4’S @ 24" O.C.

2X6 CLEAT

(TYP)

2X4 BRACING

(TYP)

PLANK DECKING

5/8" SOFFIT BRD

POST PER PLAN

IN COLUMN BEYOND

5/8" T1-11 PLAIN

SIDING O/ 2X4’S

@ 24" O.C.

CONCRETE LANDING

PER PLAN

RIM JOIST & BLKG PER PLAN

WOOD STAIRS PER PLAN

HUC PER PLAN

BEAM PER PLAN

H2.5’S PER PLAN

GUARDRAIL PER DETAIL 8/14

FASCIA PER PLAN

SEAMLESS ALUM GUTTER

DRIP EDGE FLASHING

(2) 2X4 TOP PLTS

2X6 BLKG W/ (2) 2"Ø

VENT HOLES EACH BLK

H2’S & H2.5’S PER PLAN

METAL ROOFING

O/ WATERPROFF MEMBRANE

O/ 5/8" CDX PLYWOOD

O/ ENGINEERED TRUSSES PER PLAN

CONTINUOUS SOFFIT VENT

1X3 TRIM (TYP)

SOFFIT BRD

O/ 2X4’S @ 24" O.C.

2X4 CONT

NOTE:

FASTEN PLYWOOD WALL SHEATHING

W/ 8d NAILS @ 4" O.C. BOUNDARIES,

6" O.C. EDGES & 8" O.C. FIELD.

(2) 2X4 TOP PLTS

1/2" GYP BRD

5/8" GYP BRD

FOOTING BEYOND PER PLAN

FINISH GRADE

5

14

SECTIONSCALE: 1/2"=1’-0"

5/8" T1-11 PLAIN SIDING

NO GROOVES

O/ TYVEK HOUSEWRAP OR EQUAL

O/ 2X6 STUDS @ 16" O.C.

CONCRETE SLAB

PER PLAN

VA

RIE

S12’-

6"

SP1 STUD TO BOTTOM PLT

TO ALIGN WITH RAFTERS

@ 48" O.C.

2X6 BLKG W/ (2) 2"Ø

VENT HOLES EACH BLK

H2.5’S PER PLAN (TYP)

METAL ROOFING

O/ WATERPROFF MEMBRANE

O/ 5/8" CDX PLYWOOD

O/ ENGINEERED TRUSSES PER PLAN

1X3 TRIM (TYP)

FINISH GRADE

6

14

SECTIONSCALE: 1/2"=1’-0"

1X TRIM (TYP)

POST PER PLAN IN

COLUMN BEYOND (TYP)

COLUMN BEYOND (TYP)

FOOTING BEYOND PER PLAN (TYP)

2X4 CONT (TYP)

5/8" SOFFIT BRD

O/ 2X4’S @ 24" O.C. (TYP)

CONTINUOUS SOFFIT VENT (TYP)

FASCIA PER PLAN (TYP)

SEAMLESS ALUM GUTTER (TYP)

DRIP EDGE FLASHING (TYP)

BEAM PER PLAN (TYP)

CONCRETE SLAB

PER PLAN

5/8" SOFFIT

BRD

FASCIA PER PLAN

SEAMLESS ALUM GUTTER

DRIP EDGE FLASHING

(2) 2X4 TOP PLTS

2X6 BLKG W/ (2) 2"Ø

VENT HOLES EACH BLK

H2’S & H2.5’S PER PLAN

METAL ROOFING

O/ WATERPROFF MEMBRANE

O/ 5/8" CDX PLYWOOD

O/ ENGINEERED TRUSSES PER PLAN

CONTINUOUS SOFFIT VENT

1X3 TRIM (TYP)

SOFFIT BRD

O/ 2X4’S @ 24" O.C.

2X4 CONT

NOTE:

FASTEN PLYWOOD WALL SHEATHING

W/ 8d NAILS @ 4" O.C. BOUNDARIES,

6" O.C. EDGES & 8" O.C. FIELD.

1/2" GYP BRD

5/8" GYP BRD

5/8" T1-11 PLAIN SIDING

NO GROOVES

O/ TYVEK HOUSEWRAP OR EQUAL

O/ 2X6 STUDS @ 16" O.C.

9’-

0"

FASCIA PER PLAN

SEAMLESS ALUM GUTTER

DRIP EDGE FLASHING(2) 2X4 TOP PLTS

METAL ROOFING

O/ WATERPROFF MEMBRANE

O/ 5/8" CDX PLYWOOD

O/ ENGINEERED TRUSSES PER PLAN

CONTINUOUS SOFFIT VENT

1X3 TRIM (TYP)

SOFFIT BRD

O/ 2X4’S @ 24" O.C.

2X4 BLKG

10’-

0"

2X6 CLEAT

(TYP)

2X4 BRACING

(TYP)

FOOTING BEYOND PER PLAN

1X4 SKIRTING

POST BEYOND PER PLAN (TYP)

BEAM PER PLAN (TYP)

RIM JOIST & BLKG PER PLAN

2X10 BOTTOM BAND

FINISH GRADE

CS20X34" POST TO

BEAM BELOW

1/2" GYP BRD

5/8" GYP BRD

7

14

SECTIONSCALE: 1/2"=1’-0"

5/8" T1-11 PLAIN SIDING

NO GROOVES

O/ TYVEK HOUSEWRAP OR EQUAL

O/ 2X6 STUDS @ 16" O.C.

2X6 BLKG

RIM JOIST & BLKG PER PLAN

CS20X36" STUD TO

BEAM -TO ALIGN WITH

RAFTERS @ 48" O.C.

WATERPROOF FLASHING

3/4" T&G PLYWOOD

O/ FLOOR JOISTS

PER PLAN

2X4 BOTTOM PLT

2X4 BOTTOM PLT

3/4" T&G PLYWOOD

O/ FLOOR JOISTS

PER PLAN

HL33 AT EACH TRUSS

WINDOW PER PLAN

DBL 2X4 SILL

HEADER PER PLAN

MAX

MA

XM

IN

2X TOP RAIL

CONCRETE LANDING

PER PLAN

HL33 AT EACH STRINGER

4X12 TREAD (TYP)

TA10 TREAD TO STRINGER (TYP)

NOTCH NEWEL POST

AT STRINGER AND

FASTEN W/ (2) 5/8"Ø

THRU BOLTS W/ NUTS

& WASHERS

DETAILSCALE: 1"=1’-0"

3’-

0"

7 3

/4"

11"

3 1

/2 "

8"

6"

2X2 PICKETS

MAX 4" SPACING

2X4 BOTTOM RAIL

STRINGER PER PLAN

4X OR 6X NEWEL POST

8

14

1414

WALL SECTIONS

& DETAILS

AS NOTED

Page 15: REVISIONS BY€¦ · STEPHEN & MICHELLE SAKOMAN HAKALAU, HAWAII T.M.K. (3) 3-1-001:048 11/18/2013 2. Portland cement shall conform to A.S.T.M. Spec. C-150 (type "V" sulfate resistant).

REVISIONS BY

Sig

natu

re

will be under m

y observation.

This w

ork w

as prepared by

me o

r u

nder m

y s

upervision,

co

nstru

ctio

n o

f th

is p

ro

ject

co

nstru

ctio

n o

f th

is p

ro

ject

me o

r u

nder m

y s

upervision,

This w

ork w

as prepared by

M:\Jobs\Jobs 2013\P13-026\Sheets\Sheet-15.dgn $DATE$

75

-59

44

Ku

ak

ini

Hw

y.

#2

Pete

Pip

er

33

1-2

24

4

Kail

ua-K

on

a,

HI

96

74

0

PIP

ER

DE

SIG

NS

JOB # :DRAWN :

DRAWING:

SCALE :

DATE :

SHEET

SHEETSOF

II

AW

A

H

U.S.A

.

PR

OF

ES

SIO

NA

L

AR

CH

ITE

CT

AR

11532

LIC

EN

SE

D

S

YF

EJ

GL

.E

R

F

SO

R

EX

PIR

ES

04

/30

/20

14

PD

A P

RO

PO

SE

D N

EW

RE

SID

EN

CE

FO

R:

P13-026PJP

15

HA

KA

LA

U,

HA

WA

II

T.M

.K. (3

) 3-1

-001:0

48

ST

EP

HE

N &

MIC

HE

LL

E S

AK

OM

AN

11/18/2013

D/W

REF

TANK

W/H

VAC

ELECTRICAL PLAN (1ST FLOOR)

SCALE: 1/4"=1’-0"

R

RR

R

R

R

R R

R

R

R

R

R

R RR

R

R R

R

R

R

RR

R

R

R

R

RR

R R

RR

R

R

R

R

RR

R

R R R R

R RR

R

R

R R

R

R

R

RR

RR

R

RR

R R

RR

R R

RR

R R

R

R

R

R

S

S

S

SS

SS S

S SS

R

PANEL B

VERIFY

HEIGHT

CLEARANCE

S

S3S3

S3

S3

S

S

S

SSSS

R

R

R

R

R

RR

R

R

SS

S

SS

DS

F

SS

SS

S

S

S

SS

SD

SFS

F

R R

S

SF

SF

SD

ME

TE

R

OPENEROPENER

S3

S3

S3

SD

S

S3

S3

S

S

S

SF

SD

SF

SFSFSD

S

SDS

F

TV

TV

SD

SD

SD

SD

SD

SD

TO LIGHHT ABOVE

EXHAUST FAN

& LIGHT

EXHAUST FAN

& LIGHT

D/W

DISPOSAL

R

TV

TV

TV

SINGLE POLE SWITCH

3 WAY SWITCH

DUPLEX RECEPTACLE

LEGEND

220V SINGLE RECEPTACLE

TELEVISION OUTLET

TELEPHONE OUTLET

SMOKE DETECTOR

S

PUSH BUTTON

DUPLEX FLOOR RECEPTACLE

QUADRUPLEX RECEPTACLE

R

S

S

S3

SD

TV

VANITY STRIP LIGHT

SD

SD3

SF

EXHAUST FAN

DIMMER SWITCH

3 WAY DIMMER SWITCH

FAN CONTROL SWITCH

TRACK LIGHTING

PENDANT INCANDESCENT

FL EXHAUST FAN W/ LIGHT

CEILING FAN

DOOR SWITCHD/S

S

8’ SURFACE MOUNT

2 TUBE FLUORESCENT

4’ SURFACE MOUNT

2 TUBE FLUORESCENT

UNDER CABINET 1 TUBE FLUORESCENT

2’ SURFACE MOUNT 1 TUBE FLUORESCENTS

S 2’ SURFACE MOUNT 2 TUBE FLUORESCENT

P

WALL MOUNT LIGHT

8" RECESSED LIGHT

SURFACE MOUNT LIGHT

WALL MOUNT LIGHT (SCONCE)

TO FLUORESCENT

LIGHTS ABOVE CABINETS

SS

SS

SS

TO FLUORESCENT

LIGHTS ABOVE

CABINETS

TO FLUORESCENT

LIGHTS ABOVE

CABINETS

S3

S3

SFSD3

S3

R

RR

R

S3

S3

+32"

FL

S3

S3

J-BOX FOR

TOWEL

WARMER

FL

S

FL

S

PP

S3

S3

R

R R

R

R R

SD3

S3S

S4

S4

SD3

SS

J

S3

S3

S

SD

R R

R R

R R

REFRIG

TO FLUORESCENT

LIGHTS ABOVE CABINETSSS

R

S

P

P

P

RR

S4

S

FL

3 SWITCHES

TO FAN/LIGHT

S

3 SWITCHES

TO FAN/LIGHT

3 SWITCHES

TO FAN/LIGHT

EXHAUST FAN

CHANDALIER LIGHT

S

S

FL

R

S

SS

PA

NE

L A

SD

TV

RR

TO SWITCH

BELOW

S3

R

R

R

R

R

R

R

SDS

F

SFS

D

SS

S J-BOX FOR

TOWEL

WARMER

SJ

+32"

FL

S

3 SWITCHES

TO FAN/LIGHT

1515

1/4"=1’-0"

ELECTRICAL PLANS