These instructions must be read fully before commencing installation. REVOLUTION SLC Installation & Maintenance
Transcript
Page 1: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

These instructions must be read fully before commencing installation.

REVOLUTION SLC Installation & Maintenance

Page 2: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Tel 01384 275800 Fax 01384 275810 Email [email protected] Website eltafans.com2

Installation InstructionsREVOLUTION SLC

1.0 General1.1 It is important these Installation and Maintenance Instructions are fully adhered to.1.2 Full details of the unit supplied are shown on the product nameplate. If in doubt about any detail contact Elta Fans Ltd or its agents for clarification.1.3 All electrical installation must be carried out by suitably qualified and competent personnel in accordance with all current statutory requirements.1.4 These instructions cover only the Elta Fans Ltd product and do not include the supply or installation of any safety equipment that may be required e.g. adequate guarding or protection from rotating parts and proper electrical isolation.1.5 Any declarations made by Elta Fans Ltd about product installation and safety, are dependant on the fan equipment being used within installations which themselves meet the requirements of the relevant Standards and Directives of your region.1.6 The fan is designed for use in an ambient temperature of -20°C up to +54°C and up to 95% relative humidity. EC fans are designed for ambient temperatures up to +60°C. The fan is not suitable for corrosive or explosive atmospheres.1.7 The installer should provide easy access to the fan to facilitate future maintenance.1.8 The installer should ensure the fan is adequately supported.1.9 This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the product by a person responsible for their safety. Children should be supervised to ensure that they do not play with the product.

2.0 Installation

WARNING – The fan must be isolated from the power supply during installation and maintenance. The fan must be earthed in accordance with the local regulations.

2.1 Upon receipt, the fan equipment should be visually inspected to check for any damage. Ensure that the impeller is free to rotate.2.2 If there are any queries concerning the fan equipment, Elta Fans Ltd should be contacted prior to the installation.2.3 The fan must be securely mounted in the desired position to suit the application. The fan can be mounted at any angle.2.4 Check the details on the motor rating plate to ensure that the correct power supply (voltage, frequency and phase) is available. An incorrect power supply will lead to permanent damage to the fan motor.2.5 Refer to the appropriate wiring diagram. Ensure that all earth connections are made.2.6 Means for electrical disconnection must be incorporated in the wiring installation in accordance with the relevant wiring and electrical regulations.2.7 Precaution must be taken to locate the exhaust discharge terminal so as to avoid the backflow of gases into the room from the open flue of gas or other fuel burning appliances.

3.0 Start Up

WARNING – It is not good for any fan motor, for the user to use the power supply isolator to a fan as a means of day to day control. This can reduce the life expectancy of the fan motor and may even lead to motor failure unlikely to be covered under our warranty. The power supply isolator should only be used as a means of isolation of the power supply for maintenance and servicing requirements. Day to day control should be provided to the user by means of one of the various type of control options as per the wiring diagrams which follow in this document.

To help protect our fan motors, there is a delayed start function when the mains power is switched off at the isolator. A period of at least 5 minutes should be allowed between power disconnection and reconnection. If the user is determined to switch the fan on and off at the power supply isolator then the installer must advise the user of this motor protection function so that they wait the necessary period of up to 5 minutes between switching on and off.

WARNING – When switching off mains power for maintenance / servicing, High voltages are present at the terminals and within the motor for up to 10 minutes after disconnection of the electrical supply.

3.1 Before power is supplied to the unit, check that the wiring is correct as per the fan connection diagram.3.2 At initial start-up, check that impeller rotation and airflow direction is correct.3.3 Check that the motor amperage draw does not exceed the nameplate rating. EC fans only:3.4 Minimum interval between consecutive starts: 5 minutes.3.5 Maximum 1 connection from power supply cycle per 5 minutes.

AC

Page 3: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 3

Installation InstructionsREVOLUTION SLC AC

4.0 Fan Maintenance4.1 Inspection of the fan at least once every 12 months is recommended to ensure that the motor, fan blades, and supporting guards, are clean. Any build up of dust and deposits on the blades or guards should be removed using a non-abrasive cleaner.4.2 All fastenings should be checked for tightness. In addition, all rotating items should be checked.4.3 Bearings are of the ‘sealed for life’ type and will not need a detailed inspection.

WARNING – Fuses/circuit breakers are used to provide short circuit protection only. A starter panel with overload protection should be used to protect the motor. Only a suitably qualified and competent person may carry out maintenance after the electrical supply has been isolated.

5.0 Guarantee Elta Fans Ltd will, free of charge, within a period of 1 year from the date of dispatch from their works, repair or at its option replace any goods which are proved to have defects as a result of defective materials or workmanship. The goods MUST be returned to Elta Fans Ltd carriage paid for examination.

Page 4: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Tel 01384 275800 Fax 01384 275810 Email [email protected] Website eltafans.com4

Installation InstructionsREVOLUTION SLC AC

A3A3SLC-ACC-GA

1:20

SLC GA

BELL MOUTH INLETACCESSORY AVAILABLE

FROM ELTA

FLEXIBLE CONNECTIONACCESSORY AVAILABLE

FROM ELTAMATCHING FLANGE

ACCESSORY AVAILABLEFROM ELTA

IMPELLER SIDE GUARDACCESSORY AVAILABLE

FROM ELTA

DAMPERACCESSORY AVAILABLE

FROM ELTA

MOUNTING FEETACCESSORY AVAILABLE

FROM ELTA

FAN UNIT

NOTE:FIXINGS SUPPLIED

BY CUSTOMER

REFER TO CATALOGUE/OFFICEFOR ACCESSORY DETAILS

SILENCERACCESSORY AVAILABLE

FROM ELTA

FAN WITHMATCHING FLANGES

FAN WITHFLANGES AND FLEXIBLE

CONNECTIONS

FAN WITHMOUNTING FEET

FAN WITHMOUNTING FEET AND AV

MOUNTS

FAN WITHBELL MOUTH INLET

FAN WITHDAMPER

FAN WITHIMPELLER SIDE GUARDS

AV MOUNTACCESSORY AVAILABLE

FROM ELTATYPE DEPENDANT

ON FAN SIZE

FAN WITHSILENCERS

1

2

3

4

5

7

6

3rd ANGLE PROJECTION DO NOT SCALE-IF IN DOUBT, ASK!

DRAWING No.

SHEET OF ISSUE

DRAWN BY

DATE

SCALE STATUS

APPROVED

CHECKED

FINISH

MATERIAL

SPECIFICATION

DIMENSIONS ARE IN mm UNLESS STATED OTHERWISE

THIS IS A C.A.D. PRODUCED DRAWING

AND THEREFORE NO SUBSEQUENTMANUAL MODIFICATIONS WILL BE

ALLOWED.

TITLE

UNLESS OTHERWISE STATED.

BYISS CN.

DATE CHKD

ISS CN. BY

DATE

CHKD

ISS CN. BY

DATE CHKD

ISS CN. BY

DATE CHKD

A

1

B C D E F G

2

3

4

5

7

6

7

6

5

4

3

2

1

A CB E F G

DATE

ISS CN.

CHKD DATE

BY ISS CN.

CHKD

BY

DATE

ISS CN.

CHKD DATE

BYCN. ISS

CHKD

BY

N/A

N/A

1 1 A

AWM

03-03-15

DMO

-

I

USED ON

OF THESE VIEWS FOR MANUFACTURINGPURPOSES ARE AT SUPPLIERS RISK.

REFERENCE PURPOSES ONLY. USE

ANY DEVELOPMENT VIEWS SHOWN ONTHIS DRAWING ARE SHOWN FOR

ORIENTATION OF FAN MUST BE AS PER

DRAWING OR REFER TO ELTA

GENERAL ± 1.0TOLERANCES

N/A

D

in writing from its owners Elta Fans Ltd.

purpose other than that for which it is supplied

speci�cation document which is supplied incon�dence and which must not be used for any

and must not be reproduced without permission

Elta Fans Ltd. own the copyright of this drawing/

Tel. 01489 566500 Fax. 01489 566555FAREHAM, HAMPSHIRE. PO15 5ST.SEGENSWORTH INDUSTRIAL ESTATE,17 BARNES WALLIS ROAD,ELTA FANS LTD,

C

Page 5: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 5

REVOLUTION SLCInstallation Instructions

GND 10V E1

MIN MAX

E1GND

ST1

ST2

ST2

E110VGND

MAXMIN

ST1

GND E1

THE ABOVE DIAGRAM SHOWS "ST2".

"ST2" CONNECTIONS ARE FACTORY FITTED.

GND = COMMON•10V = 10VDC INPUT•E1 = 0-10VDC OUTPUT•

YOU CAN DETERMINE THE CURRENT VDC OUTPUT BYDISCONNECTING POWER TO THE UNIT, SETTING AMULTIMETER TO OHMS (Ω) AND PLACING THE TEST PROBESBETWEEN GND AND E1

PLEASE USE THE ESTIMATED ADJUSTMENT GUIDE FOR REFERENCE

THIS IS THE INTERNAL POTENTIOMETERTHIS POTENTIOMETER CAN BE ADJUSTED FOR SINGLE SPEED SETTING OR MAX SPEED SELECTION

THIS LINK/JUMPER SHOULD BE REMOVEDWHEN USING AN EXTERNAL POTENTIOMETEROR EXTERNAL CONTROL SIGNAL CONNECTEDTO "ST1"

THE ABOVE DIAGRAM SHOWS "ST1".

"ST1" CONNECTIONS ARE CLASSED AS"CUSTOMER/USER CONNECTIONS".

GND = COMMON•+ = VDC OUTPUT AS SET BY•

INTERNAL POTENTIOMETERE1 = 0-10VDC INPUT•

149-CD-POT

10/07/2018MK-149-CD-POT Issue: Saved Date:A

All wiring and control equipment must comply to the latest IEE regulations, in particular part 552-01-02/03. 149-CD-POT Issue A: 10.07.2018Check the individual product accessories table for fan controller compatibility.

149-CD-POTThe 149-CD-POT is a commissiong device designed to be used with our EC range of fans. The device will allow the for the installer to set the maximum operating speed of the fan that it is connected to. The installer or commissioning engineer can adjust the fan speed using the potentiometer built onto the 149-CD-POT board. This potentionmeter can either be used for single speed adjustment or to set a maximum speed for the fan to operate at when an external control source is used. If external speed control is required, the jumper connection next to the potentionmeter on the board would need to be removed, the installer can then connect to ST1 (using the diagram provided). When an external speed control is fitted, the maximum speed setting available to the external control is limited by the potentiometer setting of the commissioning device.

EC

Please note: This is an estimated adjustment guide

149-CD-POT

The 149-CD-POT is a commissiong device designed to be used with our EC range of fans.

This device will be as standard with our box fan range from May 2018.

The device will allow the for the installer to set the maximum operating speed of the fan that it isconnected to.

The installer or commissioning engineer can adjust the fan speed using the potentiometer built onto the149-CD-POT board. This potentionmeter can either be used for single speed adjustment or to set amaximum speed for the fan to operate at when an external control source is used.

If external speed control is required, the jumper connection next to the potentionmeter on the boardwould need to be removed, the installer can then connect to ST1 (using the diagram provided).

When an external speed control is �tted, the maximum speed setting available to the external control islimited by the potentiometer setting of the commissioning device.

10/07/2018MK-149-CD-POT Issue: Saved Date:A

Level / Speed OHMS (Ω)

10 10 (Ω)

9 9 (Ω)

8 8 (Ω)

7 7 (Ω)

6 6 (Ω)

5 5 (Ω)

4 4 (Ω)

3 3 (Ω)

2 1.5 (Ω)

1 500 (Ω)

0 1 (Ω)149-CD-POT

Page 6: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Tel 01384 275800 Fax 01384 275810 Email [email protected] Website eltafans.com6

Single Phase 220V - 240V / 50Hz Three Phase 380V - 415V / 50Hz

PageNo.

Product Code

Wiring Diagram No.

7 SLC400/4-1AC 152-502

7 SLC450/2-1AC 152-502

7 SLC450/4-1AC 152-502

7 SLC500/4A-1AC 152-502

7 SLC500/4B-1AC 152-502

7 SLC560/4A-1AC 152-502

7 SLC560/4B-1AC 152-502

7 SLC630/4-1AC 152-502

7 SLC630/4B-1AC 152-502

PageNo.

Product Code

Wiring Diagram No.

8 SLC315/4-3AC 152-600

8 SLC355/2A-3AC 152-600

8 SLC450/2A-3AC 152-600

8 SLC450/4-3AC 152-600

9 SLC500/2A-3AC 152-601

9 SLC500/2B-3AC 152-601

8 SLC500/4A-3AC 152-600

8 SLC500/4B-3AC 152-600

9 SLC560/2-3AC 152-601

8 SLC560/4A-3AC 152-600

8 SLC560/4B-3AC 152-600

8 SLC560/4C-3AC 152-600

8 SLC630/4A-3AC 152-600

8 SLC630/4B-3AC 152-600

8 SLC710/4A-3AC 152-600

9 SLC710/4B-3AC 152-601

8 SLC710/6A-3AC 152-600

8 SLC710/6B-3AC 152-600

9 SLC800/4A-3AC 152-601

9 SLC800/4B-3AC 152-601

8 SLC800/6A-3AC 152-600

9 SLC800/6B-3AC 152-601

9 SLC900/4A-3AC 152-601

9 SLC900/4B-3AC 152-601

9 SLC900/6A-3AC 152-601

9 SLC900/6B-3AC 152-601

8 SLC900/8-3AC 152-600

9 SLC1000/4A-3AC 152-601

9 SLC1000/4B-3AC 152-601

9 SLC1000/4C-3AC 152-601

9 SLC1000/6A-3AC 152-601

9 SLC1000/6B-3AC 152-601

8 SLC1000/8-3AC 152-600

Wiring DiagramsREVOLUTION SLC

Please use the table(s) below to match up the product code and the wiring diagram number.

AC

Page 7: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 7

Single Phase 220V - 277V / 50Hz or 60Hz

PageNo.

Product Code

Wiring Diagram No.

10 SLC315-1EC 152-710

10 SLC355-1EC 152-710

10 SLC400-1EC 152-710

10 SLC450-1EC 152-710

10 SLC500-1EC 152-710

10 SLC560-1EC 152-710

10 SLC630-1EC 152-710

Wiring DiagramsREVOLUTION SLC

Please use the table(s) below to match up the product code and the wiring diagram number.

EC

Page 8: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Tel 01384 275800 Fax 01384 275810 Email [email protected] Website eltafans.com8

Wiring Diagrams152-502 AC

16/08/2018MK-152-502 Issue: Saved Date:D

ALL WIRING AND CONTROL EQUIPMENT MUST COMPLY TO THELATEST IEE REGULATIONS, IN PARTICULAR PART 552-01-02/03

VARIABLE SPEED CONNECTION CONTROLLER TYPE TC12, TC14,TC18, TC110, TC112

BROW

N

BROW

N

BLUE

GREE

N/YE

LLOW

EL N

CONTROLLERTERMINAL BOX

GREE

N/YE

LLOW

BROW

N

BLUE

REMOVE LINKBETWEEN U1 - Z2 Z2U1 Z1

U2CAP1 CAP2

220 - 240V 1PH 50Hz SUPPLY

AUXNL NLE

ENL

Z2U1 Z1

U2CAP1 CAP2

220 - 240V 1PH 50Hz SUPPLY

FIXED SPEED CONNECTION

GREE

N/YE

LLOW

BLUE

BROW

N

All wiring and control equipment must comply to the latest IEE regulations, in particular part 552-01-02/03. MK-152-502 Issue D: 16.08.2018Check the individual product accessories table for fan controller compatibility.

Page 9: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 9

Wiring Diagrams152-600 AC

Y RECONFIGURED BY CUSTOMER TO Δ FOR USE WITH 1PH - 3PH INVERTER

4 5 6 731 2 8 11109L1/L U V WL3L2/N

BROW

N

BLAC

K

GREY

GREE

N/YE

LLOW

BROW

N

BLUE

GREE

N/YE

LLOW

1 TO 7PRE - WIRED

EL

FAN TERMINALBOX *

220 - 240V 1PH 50Hz SUPPLYN

10 RELAY COMMON11 RELAY CONTACT

1PH - 3PHIP55 INVERTER

ANALOG / DIGITALINPUT CONNECTIONS

V1 W1U1

V2U2W2

* STANDARD Y CONNECTED MOTOR WILL NEED TO BE RECONNECTEDTO Δ TO OPERATE WITH 1PH - 3PH INVERTER, ENSURE FAN IS SUITABLE

FOR THIS CONNECTION.IF IN DOUBT CONTACT ELTA FANS

4 5 6 731 2 8 11109L1/L U V WL3L2/N

W2 U2 V2

U1 W1V1

L3

3PH Y CONNECTED FAN C/W INVERTER

ANALOG / DIGITALINPUT CONNECTIONS

3PH - 3PHIP20 INVERTER

10 RELAY COMMON11 RELAY CONTACT

L2380 - 440V 3PH 50Hz SUPPLY

FAN TERMINALBOX

L1 E

1: +24V OUTPUT2: STOP/RUN DI13: FWD/REV DI24: ANALOG/PRESET DI35: +10V OUTPUT6: ANALOG INPUT7: 0V

GREE

N/YE

LLOW

GREY

BLAC

K

BROW

N

GREE

N/YE

LLOW

GREY

BLAC

K

BROW

N

L2 EL3L1

380 - 440V 3PH 50Hz SUPPLY

FIXED SPEED Y CONNECTION

W2 U2 V2

U1 W1V1

FAN TERMINALBOX

GREE

N/YE

LLOW

GREY

BLAC

K

BROW

N

4 5 6 731 2 8 11109L1/L U V WL3L2/N

BROW

N

BLAC

K

GREY

GREE

N/YE

LLOW

BROW

N

BLAC

K

GREY

GREE

N/YE

LLOW

1 TO 7PRE - WIRED

EL1

FAN TERMINALBOX

380 - 440V 3PH 50Hz SUPPLYL2

10 RELAY COMMON11 RELAY CONTACT

3PH - 3PHIP55 INVERTER

ANALOG / DIGITALINPUT CONNECTIONS

3PH Y CONNECTED FAN C/W INVERTER

L3

V1 W1U1

V2U2W2

380 - 440V 3PH 50Hz SUPPLY

VARIABLE SPEED Y CONNECTION CONTROLLER TYPE TC33, TC35, TC310

L1 L2 L3E

CONTROLLERTERMINAL BOX

V1 W1U1

V2U2W2

FAN TERMINALBOX

GREE

N/YE

LLOW

GREY

BLAC

K

BROW

N

GREE

N/YE

LLOW

GREY

BLAC

K

BROW

N

WE L3 U VL2L1

L1/L U V WL3L2/N 4 5 6 731 2 8 11109

BROW

N

BLAC

K

GREY

GREE

N/YE

LLOW

BROW

N

BLUE

GREE

N/YE

LLOW

1: +24V OUTPUT2: STOP/RUN DI13: FWD/REV DI24: ANALOG/PRESET DI35: +10V OUTPUT6: ANALOG INPUT7: 0V

EL

FAN TERMINALBOX *

220 - 240V 1PH 50Hz SUPPLYN

10 RELAY COMMON11 RELAY CONTACT

1PH - 3PHIP20 INVERTER

ANALOG / DIGITALINPUT CONNECTIONS

V1 W1U1

V2U2W2

* STANDARD Y CONNECTED MOTOR WILL NEED TO BE RECONNECTEDTO Δ TO OPERATE WITH 1PH - 3PH INVERTER, ENSURE FAN IS SUITABLE

FOR THIS CONNECTION.IF IN DOUBT CONTACT ELTA FANS

Y RECONFIGURED BY CUSTOMER TO Δ FOR USE WITH 1PH - 3PH INVERTER

ALL WIRING AND CONTROL EQUIPMENT MUST COMPLY TO THELATEST IEE REGULATIONS, IN PARTICULAR PART 552-01-02/03

29/04/2015MK-152-600 Issue: Saved Date: BAll wiring and control equipment must comply to the latest IEE regulations, in particular part 552-01-02/03. MK-152-600 Issue B: 29.04.2015Check the individual product accessories table for fan controller compatibility.

Page 10: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Tel 01384 275800 Fax 01384 275810 Email [email protected] Website eltafans.com10

Wiring Diagrams152-601 AC

L1/L U V WL3L2/N 4 5 6 731 2 8 11109

L3

3PH Δ CONNECTED FAN C/W INVERTER

ANALOG / DIGITALINPUT CONNECTIONS

3PH - 3PHIP20 INVERTER

10 RELAY COMMON11 RELAY CONTACT

L2

380 - 440V 3PH 50Hz SUPPLY

FAN TERMINALBOX

L1 E

1: +24V OUTPUT2: STOP/RUN DI13: FWD/REV DI24: ANALOG/PRESET DI35: +10V OUTPUT6: ANALOG INPUT7: 0V

GREE

N/YE

LLOW

GREY

BLAC

K

BROW

N

W2 U2 V2

U1 W1V1

GREE

N/YE

LLOWGR

EY

BLAC

K

BROW

NBR

OWN

BLAC

K

GREY

GREE

N/YE

LLOW

FAN TERMINALBOX

L2 EL3L1

380 - 440V 3PH 50Hz SUPPLY

FIXED SPEED Δ CONNECTION

W2 U2 V2

U1 W1V1

1 TO 7PRE - WIRED

10 RELAY COMMON11 RELAY CONTACT

L3

ANALOG / DIGITALINPUT CONNECTIONS

3PH - 3PHIP55 INVERTER

L2

380 - 440V 3PH 50Hz SUPPLY

FAN TERMINALBOX

L1 E

GREE

N/YE

LLOW

GREY

BLAC

K

BROW

N

W2 U2 V2

U1 W1V1

GREE

N/YE

LLOWGR

EY

BLAC

K

BROW

N

3PH Δ CONNECTED FAN C/W INVERTER

9 10 11821 3 7654L2/N L3 WVUL1/L

GREY

BLAC

K

BROW

N

GREE

N/YE

LLOW

GREY

BLAC

K

BROW

N

GREE

N/YE

LLOW

FAN TERMINALBOX

W2 U2 V2

U1 W1V1

380 - 440V 3PH 50Hz SUPPLY

VARIABLE SPEED Δ CONNECTION CONTROLLER TYPE TC33, TC35, TC310

L1 L2 L3E

CONTROLLERTERMINAL BOXWE L3 U VL2L1

ALL WIRING AND CONTROL EQUIPMENT MUST COMPLY TO THELATEST IEE REGULATIONS, IN PARTICULAR PART 552-01-02/03

15/07/2013MK-152-601 Issue: Saved Date: BAll wiring and control equipment must comply to the latest IEE regulations, in particular part 552-01-02/03. MK-152-601 Issue B: 15.07.2013Check the individual product accessories table for fan controller compatibility.

Page 11: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 11

Wiring Diagrams152-710

NOTE: TAG REFERENCES RELATE TO MOTOR CONTROL WIRES, AND NOT 149-POT-10

ALL WIRING AND CONTROLS EQUIPMENT MUST COMPLY TO THELATEST IET REGULATIONS, IN PARTICULAR PART 552-01-02/03

10/09/2019MK-152-710 Issue: Saved Date:D

NOTE:*JUMPER REMOVED WHEN EXTERNALSWITCH IS USED.

ONE WAY SWITCHNOTE:*JUMPER REMOVED WHEN EXTERNALCONTROL SOURCE IS USED.

149-CD-POT

ST2

ST1

GND E1

MIN

E110VGND

GREE

N/YE

LLOW

BROW

N

BLUE

1PH EC SINGLE FAN C/W 149-CD-POT & 149-POT-10

SINGLE FAN

220 - 277V 1PH 50HzMAINS SUPPLY

BROWN

BLUE

YELLOW

WHITE

BLUE

RED

CONT

ROLS

POW

ER

L N PE

MAX SPEEDTRIMMER

JUMPERREMOVED *

BROWN

BLACK

G/Y

G/Y

149-POT-10

2 7 6 51

14

32

NL

56

MAX

FOR USE WITH:SLC315-1ECSLC355-1ECSLC400-1ECSLC450-1ECSLC500-1ECSLC560-1ECSLC630-1ECSLC710-1EC

0-10V DC INPUT (IF REQUIRED)

0-10 VDCGND

G/Y

149-CD-POT

ST2

ST1

GND E1

MAXMIN

E110VGND

GREE

N/YE

LLOW

BROW

N

BLUE

1PH EC SINGLE FAN C/W 149-CD-POT & 0-10VDC INPUT

SINGLE FAN

220 - 277V 1PH 50HzMAINS SUPPLY

BROWN

BLUE

YELLOW

WHITE

BLUE

RED

CONT

ROLS

POW

ER

L N PE

POTENTIOMETER FOR SINGLESPEED ADJUSTMENT OR MAXSPEED SELECTION

REMOVE LINK WHEN USINGEXTERNAL POTENTIOMETER OREXTERNAL CONTROL SIGNAL

BROWN

BLACK

14

32

NL

56

G/Y

FOR USE WITH:SLC315-1ECSLC355-1ECSLC400-1ECSLC450-1ECSLC500-1ECSLC560-1ECSLC630-1ECSLC710-1EC

MAX

65

LN

23

41

G/Y

G/Y

BLACK

BROWN

JUMPERREMOVED *

MAX SPEEDTRIMMER

PENL

POW

ERCO

NTRO

LS

RED

BLUE

WHITE

YELLOW

BLUE

BROWN

220 - 277V 1PH 50HzMAINS SUPPLY

SINGLE FAN

1PH EC SINGLE FAN C/W ONE WAY SWITCHBL

UE

BROW

N

GREE

N/YE

LLOW

GND 10V E1

MIN

E1GND

ST1

ST2

149-CD-POT

FOR USE WITH:SLC315-1ECSLC355-1ECSLC400-1ECSLC450-1ECSLC500-1ECSLC560-1ECSLC630-1ECSLC710-1EC

-

Tag Purpose Description

L Live Live power supply, 220-277V

N Neutral Neutral from power supply

Permanent Earth Permanent earth from power supply

1 DC Voltage [2-10V] DC control voltage input(2 to 10VDC input)

2 DC Current [4-20mA] DC control current input(4 to 20mA input)

3 Frequency [10-95%]Frequency duty-cycle (PWM)

Voltage: 10 to 24VpkFrequency: 80Hz(10 to 95% input)

4 Speed Reference Tacho output

5 10VDC output 10VDC source output

6 GND / Common DC Common

All wiring and control equipment must comply to the latest IEE regulations, in particular part 552-01-02/03. MK-152-710 Issue D: 10.09.2019Check the individual product accessories table for fan controller compatibility.

NOTE: Tag refernces relate to motor control wires and not 149-POT-10

EC

Tag Purpose Description

L Live Live power supply, 220-277V

N Neutral Neutral from power supply

Permanent Earth Permanent earth from power supply

1 DC Voltage [2-10V] DC control voltage input(2 to 10VDC input)

2 DC Current [4-20mA] DC control current input(4 to 20mA input)

3 Frequency [10-95%]Frequency duty-cycle (PWM)

Voltage: 10 to 24VpkFrequency 80Hz(10 to 95% input)

4 Speed Reference Tacho output

5 10VDC output 10VDC source output

6 GND / Common DC Common

Page 12: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Tel 01384 275800 Fax 01384 275810 Email [email protected] Website eltafans.com12

EU Declaration of Conformity Declaration of Incorporation

Description of Equipment:Building Services Ranges - Air movement fan

Equipment model numbers for safe area fans:SCP, SPA, SAX, SCD, SDA, SCC, SLC, SCPP, SPP, SAMF, HIT, SEM, SEL, ISEO IMF, SH, SSD, SQS, SQSDCV, SQU, SMB, STD, SQT, SQTDCV, SCH, SCHT, SSDR, SSDRDCV, STDR, STDRDCV, SB, SQU-HT, SSQU-HT, SDF, ZFHIC, SRC, SRC, CF, TF, SSRL, BLB, BLTF

Relevant / applied directives:Machinery directive 2006/42/EC, Low voltage directive 2014/35/EU

Relevant / applied directives where applicable:Energy related products directive 2009/125/EC (when used in Europe)Electromagnetic compatibility directive 2014/30/EU (where driven via Inverter)RoHS 2011/65/EU and its amendments (including Directive 2015/863/EU)

Relevant / applied directives where applicable:BS EN ISO 12100 : 2010BS EN 14694 : 2003 + A1 : 2011BS EN 308:1997BS EN ISO 5801:2008

In accordance with the Machinery Directive 2006/42/EC;

The design of the partly completed machine, listed above, complies with the Essential Health and Safety Requirements (EHSRs) of ANNEX I, sections 1.1.2, 1.1.5, 1.4.1, 1.5.1 in EC Machinery Directive 2006/42/EC.

Machinery is incomplete and must not be put into service until such time as the machinery which is partly complete, is to be incorporated, and has been assessed and Declared in Conformity with the provisions of any relevant parts of the Machinery Directive.

We undertake to transmit, upon reasoned request by appropriate national authorities, relevant information relating to the partly completed machinery identified above.

Manufacturer:Elta Fans Limited46 Third AvenuePensnett Trading EstateKingswinfordWest MidlandsDY6 7USUnited Kingdom

Date / Signature of Manufacturer: Document last revised: 20th July 2020

Name / Position of Signatory: Mr. Robert Rees Q.A.Manager Elta Fans LtdThis is an electronic document and is valid without a signature or date. ECD F Issue Status D

Herewith we declare that the air movement equipment below, on the basis of its design and construction as partly completed machines brought onto the market complies with relevant health and safety requirements of the EC Directives stated below. In the event that alterations are made to the machinery without prior consent from Elta Fans Ltd, this declaration becomes invalid.

EU Declaration of conformity/incorporation

Page 13: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 13

NotesREVOLUTION SLC

Page 14: REVOLUTION SLC - Amazon Web Services · 2019. 8. 16. · 2 Tel Fax 0 Email seltafansco u Website eltafans co m Installation Instructions REVOLUTION SLC 1.0 General 1.1 It is important

535-IOM0012 Issue F

eltafans.com

Tel +44 (0) 1384 275800Fax +44 (0) 1384 275810Email [email protected]

46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US United Kingdom

Tel +44 (0) 1489 566500Fax +44 (0) 1489 566555Email [email protected] / [email protected]

17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5TT United Kingdom

BS EN ISO 9001:2015 FM 556465

A member ofHEVAC ASSOCIATION

Applied Technology & Building Services Export

Building Services


Recommended