Made in
Europe
Online UPS
SENTRY FSENTRY F
Single-Phase In / Single-Phase Out Sentry F 6KVA
Riello PCI Riello PCI
Product Highlights
6KVA Online UPS.
True double-conversion online UPS.
Wide input voltage range (110 - 280VAC).
Output Power Factor 0.7.
Generator Compatible.
RS-232 port or intelligent slot for remote control.
LCD Display.
Riello PCI is one of the leading company in power protection solutions in India.
Riello PCI provides a complete range of products for all single-phase and three-phase applications.
We ensure that our products provide superior operating performance.
Riello PCI has delivered over 5000 successful installations in India & Indian Subcontinent.
Technical Support team at your service 365 days 24 x 7.
Riello PCI has the ability and the expertise to work with the customers and integrate our wide range of products to suit the most demanding power protections needs.
MODELS
INPUT
Voltage Range
Frequency Range
175V-280V ± 5% @ 100% Load
110V-280V ± 5% @ 50% Load
40Hz~70Hz
≥0.95
Prime Tower, Plot No: 287-288, Udyog Vihar, Phase – II, Gurgaon-122015, Haryana (India) Tel: +91-124-6656999 Fax: +91-124-4871698 Email: [email protected] Website: www.riellopci.com
Riello PCI India Pvt. Ltd. (A joint venture between RPS S.p.A., Italy and PCI Ltd., India)
TECHNICAL DATA
SENTRY F 6 kVA
PHASE 1 phase In / 1 phase out
CAPACITY 6000 VA / 4200 W
Power Factor
OUTPUT
Nominal Voltage
AC Voltage Regulation (Batt. Mode)
208/220/230/240 VAC
± 3%
Frequency Range (Synchronized Range)47 ~ 53 Hz @ 50 Hz system
57 Hz ~ 63 Hz @ 60 Hz system
Frequency Range (Batt. Mode) 50Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Current Crest Ratio 3:1
Harmonic Distrotion ≤ 3% THD (Linear Load), ≤ 6% THD (Non-linear Load)
Transfer TimeAC Mode to Batt. Mode
Inverter to Bypass 4 ms (Typical)
Pure Sine wave
0 ms
Waveform (Batt. Mode)
EFFICIENCY
AC Mode 90%
BATTERY
Battery Mode 85%
Backup Time Depending upon battery AH
Maximum Charging Current (±10%) 4.0 A
Battery Numbers 8
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage,
Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously Sounding
PHYSICAL
Dimension, D x W x H (mm) 480x438x88
Net Weight (kgs) 12.6
ENVIRONMENT
Humidity 0 - 95 % RH @ 0 - 40 ⁰ C (non-condensing)
Noise Level Less than 55dB @ 1 Meter
MANAGEMENT
Smart RS-232 / Optional USB CardsSupports Windows® 2000/2003/XP/Vista/2008,
Windows® 7, Linux, Unix, and MAC
Optional SNMP Power Management from SNMP manager and web browser