Rittal Fan Shrouds Rittal offers a complete line of fan shrouds. From our standard 3R/4 units or the specially engineered, vandal-resistant design to the corrosive resistant, stainless steel Type 4X rated units to be used in harsh locations – we have a shroud to meet the most stringent applications. Our Hi-Visibility blue silicone gasket quickly identifies the seal meets FDA Guideline 21 CFR 177.2600. Additionally, the material allows easy cleaning in food and beverage environments
Transcript
Page 1: Rittal Fan Shrouds · 2019. 7. 5. · design to the corrosive resistant, stainless steel Type 4X rated units to be used in harsh locations – we have a shroud to meet the most stringent

Rittal Fan Shrouds

Rittal offers a complete line of fan shrouds. From our standard 3R/4 units or the specially engineered, vandal-resistant design to the corrosive resistant, stainless steel Type 4X rated units to be used in harsh locations – we have a shroud to meet the most stringent applications.

Our Hi-Visibility blue silicone gasket quickly identifies the seal meets FDA Guideline 21 CFR 177.2600. Additionally, the material allows easy cleaning in food and beverage environments

Page 2: Rittal Fan Shrouds · 2019. 7. 5. · design to the corrosive resistant, stainless steel Type 4X rated units to be used in harsh locations – we have a shroud to meet the most stringent

Rittal North America LLCWoodfield Corporate Center 425 North Martingale Road, Suite 400 • Schaumburg, Illinois 60173 • USA Phone: 937-399-0500 • Toll-free: 800-477-4000Email: [email protected] • Website: www.rittal.us

Note: Imperial meansurements are approximate, metric measurements are exact.

Stainless Steel

For filter fan/ outlet filter

Dimensions H x W x D

inches (mm)Part No.

3237. . . .9.1 x 5.9 x 1.6

(230 x 150 x 40)3237.080

3238. . . .9.6 x 6.9 x 2.2

(245 x 176 x 55)3238.080

3239. . . .13 x 9.2 x 2.2

(330 x 233 x 55)3239.080

3240. . . ./3241. . . .15.3 x 11.1 x 3.3 (390 x 282 x 85)

3240.080

3243. . . ./3244. . . .18.9 x 13.4 x 4.3 (480 x 350 x 110)

3243.080

3245. . . .18.9 x 13.4 x 6.3 (480 x 350 x 160)

3245.080

UL Protection Category:• 3237, 3245: Type 12, 3R• 3238, 3239, 3240, and 3243: Type 12, 3, 3R, 4, and 4X

Carbon Steel, RAL 7035

For filter fan/ outlet filter

Dimensions H x W x D

inches (mm)Part No.

3237. . . .9.1 x 5.9 x 1.6

(230 x 150 x 40)3237.085

3238. . . .9.6 x 6.9 x 2.2

(245 x 176 x 55)3238.085

3239. . . .13 x 9.2 x 2.2

(330 x 233 x 55)3239.085

3240. . . ./3241. . . .15.3 x 11.1 x 3.3 (390 x 282 x 85)

3240.085

3243. . . ./3244. . . .18.9 x 13.4 x 4.3 (480 x 350 x 110)

3243.085

UL Protection Category:• 3237: Type 12, 3R• 3238, 3239, 3240, and 3243: Type 12, 3, 3R, and 4

Vandal- Resistant Design, UL Type 3RCarbon Steel, RAL 7035

For filter fan/ outlet filter

Part No.

3237. . . . 3237.090

3238. . . . 3238.090

3239. . . . 3239.090

3240. . . ./3241. . . . 3240.090

3243. . . ./3244. . . . 3243.090

Dimensional Chart

Part No. Height Depth oa_ht OA_WD d310 p285 d262 d283 DIM_A

3237.090 142.0 51.5 223.0 192.0 70.7 2 93.5 46.0 145.0

3238.090 174.0 51.5 255.0 224.0 70.7 2 109.5 62.0 177.0

3239.090 227.0 76.5 333.0 277.0 106.1 3 148.5 88.5 230.0

3240.090 275.0 76.5 381.0 325.0 106.1 3 172.5 112.5 278.0

3243.090 342.0 76.5 448.0 392.0 106.1 3 206.0 145.6 345.0