+ All Categories
Home > Documents > Robert Cooper .

Robert Cooper .

Date post: 16-Dec-2015
Category:
Upload: allan-hines
View: 213 times
Download: 0 times
Share this document with a friend
Popular Tags:
24
The SciBath Detector Robert Cooper http://neutrino.indiana.edu/rlcoope
Transcript
Page 1: Robert Cooper .

The SciBath Detector

Robert Cooper http://neutrino.indiana.edu/rlcooper

Page 2: Robert Cooper .

2

SciBath Detector• 80 L open volume of mineral

oil based liquid scintillator

• Neutrons recoil off protons, create scintillation

• 768 wavelength shifting fibers readout

• IU built custom digitizer: 12 bit, 20 MS / s

SciBath Detector for ANNIE -- R.L. Cooper

Page 3: Robert Cooper .

3

SciBath Detector• 80 L open volume of mineral

oil based liquid scintillator

• Neutrons recoil off protons, create scintillation

• 768 wavelength shifting fibers readout

• IU built custom digitizer: 12 bit, 20 MS / s

SciBath Detector for ANNIE -- R.L. Cooper

Page 4: Robert Cooper .

4SciBath Detector for ANNIE -- R.L. Cooper

Page 5: Robert Cooper .

5SciBath Detector for ANNIE -- R.L. Cooper

Sample Neutron Candidate Event

Page 6: Robert Cooper .

6SciBath Detector for ANNIE -- R.L. Cooper

Sample Muon Candidate Event

Page 7: Robert Cooper .

7SciBath Detector for ANNIE -- R.L. Cooper

n / m Particle Discrimination

Page 8: Robert Cooper .

8

• Low-light LED pulser (YZ)

• Use cosmic rays with known energy deposit (XY) requires previous calibration to count photons

• Detect 6 PEs / MeV want to improve

SciBath Detector for ANNIE -- R.L. Cooper

Calibrating the SciBath Detector

X EnergyDeposit (MeV)

Y ScintillationPhotons Collected

Z SignalVoltage (ADCs)

Page 9: Robert Cooper .

9

• Low-light LED pulser (YZ)

• Use cosmic rays with known energy deposit (XY) requires previous calibration to count photons

• Detect 6 PEs / MeV want to improve

SciBath Detector for ANNIE -- R.L. Cooper

Single-PE LED Calibration

Calibrating the SciBath Detector

X EnergyDeposit (MeV)

Y ScintillationPhotons Collected

Z SignalVoltage (ADCs)

Page 10: Robert Cooper .

10

• Low-light LED pulser (YZ)

• Use cosmic rays with known energy deposit (XY) requires previous calibration to count photons

• Detect 6 PEs / MeV want to improve

SciBath Detector for ANNIE -- R.L. Cooper

MIP Cosmic Ray Calibration Peak

Calibrating the SciBath Detector

X EnergyDeposit (MeV)

Y ScintillationPhotons Collected

Z SignalVoltage (ADCs)

Page 11: Robert Cooper .

11SciBath Detector for ANNIE -- R.L. Cooper

Fermilab Measurement Sites

MINOS Near

NuMI TargetBNB Target

10/11 – 2/122/12– 5/12

Page 12: Robert Cooper .

12SciBath Detector for ANNIE -- R.L. Cooper

MI-12 Neutron Background Run• Neutron flux ~20 m from

target

• In-line behind beam target (ground)

• 29 Feb. – 23 Apr., 2012

• 4.9x1019 total protons on target (POT)(4.5x1012 per pulse)

Page 13: Robert Cooper .

13SciBath Detector for ANNIE -- R.L. Cooper

MI-12 Neutron Background Run• Neutron flux ~20 m from

target

• In-line behind beam target (ground)

• 29 Feb. – 23 Apr., 2012

• 4.9x1019 total protons on target (POT)(4.5x1012 per pulse)

Page 14: Robert Cooper .

14SciBath Detector for ANNIE -- R.L. Cooper

MI-12 Beam Time Per PE “Group”• HIGH PE group shows

beam time structure

• MEDIUM PE group has few-ms excess – slower neutrons arriving later

• LOWEST PE group has significant excess – 200 ms lifetime from n(p, d)g neutron capture reaction

Page 15: Robert Cooper .

15SciBath Detector for ANNIE -- R.L. Cooper

BNB Neutron Energy Spectrum• En unfolded from PEs

spectrum simulation of detector response

• 2.44 ± 0.34 pulse-1 m-2 (En > 40 MeV)

• Lose sensitivity > 200 MeV;

• Neutron spectrum20 m from BNB

Raw PE Spectrum In-Beam

Page 16: Robert Cooper .

16SciBath Detector for ANNIE -- R.L. Cooper

BNB Neutron Energy Spectrum• En unfolded from PEs

spectrum simulation of detector response

• 2.44 ± 0.34 pulse-1 m-2 (En > 40 MeV)

• Lose sensitivity > 200 MeV;

• Neutron spectrum20 m from BNB

NOTE: variable PE bin width

Raw PE Spectrum In-Beam

Page 17: Robert Cooper .

17SciBath Detector for ANNIE -- R.L. Cooper

BNB Neutron Energy Spectrum• En unfolded from PEs

spectrum simulation of detector response

• 2.44 ± 0.34 pulse-1 m-2 (En > 40 MeV)

• Lose sensitivity > 200 MeV;

• Neutron spectrum20 m from BNB

Unfolded Neutron Energy Spectrum

Stat and Syst errors

Page 18: Robert Cooper .

18SciBath Detector for ANNIE -- R.L. Cooper

Direction Spectrum• High PE protons will be track-

like; can be imaged

• Principle component analysis yields eigenvector

• Back-projecting direction spectrum tends to point upstream of target ?!

• Tracking validated with cosmic rays and NuMI beam

High-PE, Proton Direction Spectrum

Page 19: Robert Cooper .

19SciBath Detector for ANNIE -- R.L. Cooper

Direction Spectrum• High PE protons will be track-

like; can be imaged

• Principle component analysis yields eigenvector

• Back-projecting direction spectrum tends to point upstream of target ?!

• Tracking validated with cosmic rays and NuMI beam

Page 20: Robert Cooper .

20SciBath Detector for ANNIE -- R.L. Cooper

Direction Spectrum• Sensitive to n(p,d)g reaction and see copious beam-correlated rate

• Accidental rates too high for capture-gating statistical sensitivity

Page 21: Robert Cooper .

21SciBath Detector for ANNIE -- R.L. Cooper

Current Studies• 2012 measurements at one

position with no shielding

• We are improving SciBath, building concrete shielding

• Locate a viable location for CENNS & CAPTAIN

• Survey the area withportable detector

Page 22: Robert Cooper .

22SciBath Detector for ANNIE -- R.L. Cooper

Current Studies• 2012 measurements at one

position with no shielding

• We are improving SciBath, building concrete shielding

• Locate a viable location for CENNS & CAPTAIN

• Survey the area withportable detector

beam

Page 23: Robert Cooper .

23SciBath Detector for ANNIE -- R.L. Cooper

Beam Off-Target Rates (> 0.5 MeV)

Stairwell• 9 m from Be

beam target• 1384 n / 1016 POT

Collimator• 8 m from Be

beam target• 5608 n / 1016 POT

50 m Absorber• 6 m from Fe

beam stop• 310 n / 1016 POT

2012 SciBath Loc• 20 m from Be

beam target• 211 n / 1016 POT

Target 90° FOX• 20 m from Be

beam target• 390 n / 1016 POT

Neutron spectrum unfolding underway

≈ 2.7×1016 / hr

Page 24: Robert Cooper .

24SciBath Detector for ANNIE -- R.L. Cooper

Summer 2015 Plans• Plan to measure near BNB target building for CENNS,

CAPTAIN, and general SBN program (May or June for 1 month)

• Measure in SciBooNE hall higher energy neutrino-induced neutrons: relevant for ANNIE, microBooNE, and SBN (May or June for 1 month)

• We want to help the neutron measurement efforts and are eager for additional support: siting, shifts, analysis, etc.


Recommended