4
ROCA L20 SINK MIXER CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty - Refer to Warranty Page for full Terms and Conditions To see the complete Roca range go to www.reece.com.au/bathrooms M8 159 392 G 1/2" 101 46,5 221 13° 132 SPECIFICATIONS Recommended use Domestic, hotel and commercial Colour availability Chrome Pressure rating Maximum continuous operating pressure 1000kPa. For best performance and longer life we recommend 150-500kPa. Hot and cold water inlet pressure should be equal. Temperature rating Maximum continuous working temperature 80°C Suitable Hot Water Units Storage tank: Yes Continuous Flow: Yes Gravity Feed: Not suitable Water Efficiency 4 Star, 7.5 L/min Standards AS/NZS 3718 page 1 of 4 Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/ distributor takes no responsibility for printing errors. Tech Page Version 1 WaterMark AS/NZS 3718 WMKA 25255 The more stars the more water efficient WATER RATING www.waterrating.gov.au In accordance with AS/NZS 6400 Licence No. 0137 Bathroom Products Australia 7.5 litres per minute
Transcript
Page 1: ROCA L20 SINK MIXER - d12qbzr1dyleru.cloudfront.net · ROCA L20 SINK MIXER INStaLLatIoN INStRUCtIoNS Important Note Mixer must be installed to the requirements of AS/NZS 3500 by a

ROCAL20 SINK MIXER

CLEANING RECOMMENDATIONSWe recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty - Refer to Warranty Page for full Terms and Conditions

To see the complete Roca range go to www.reece.com.au/bathrooms

M8

159

3

92

G 1/2"

101

46,5

221

13°

132

SPECIFICATIONSRecommended use Domestic, hotel and commercial

Colour availability Chrome

Pressure rating Maximum continuous operating pressure 1000kPa.

For best performance and longer life we recommend 150-500kPa.

Hot and cold water inlet pressure should be equal.

Temperature rating Maximum continuous working temperature 80°C

Suitable Hot Water Units

Storage tank: Yes

Continuous Flow: Yes

Gravity Feed: Not suitable

Water Efficiency 4 Star, 7.5 L/min

Standards AS/NZS 3718

page 1 of 4

Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

Tech Page Version 1

WaterMarkAS/NZS 3718WMKA 25255

The more stars the more water efficient

WATER RATINGwww.waterrating.gov.au

In accordance with AS/NZS 6400

Licence No. 0137Bathroom Products Australia

7.5 litres per minute

Page 2: ROCA L20 SINK MIXER - d12qbzr1dyleru.cloudfront.net · ROCA L20 SINK MIXER INStaLLatIoN INStRUCtIoNS Important Note Mixer must be installed to the requirements of AS/NZS 3500 by a

ROCAL20 SINK MIXER

INStaLLatIoN INStRUCtIoNS

Important NoteMixer must be installed to the requirements of AS/NZS 3500 by a qualified plumber. Your mixer comes to you already factory assembled and tested. We do not recommend the dismantling of any internal part of the mixer. The mixers are factory tested and sealed so as to give the best performance.

page 2 of 4

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

6545

kPa

kPa

1000

500 MAX

MIN100

300

200

23

Page 3: ROCA L20 SINK MIXER - d12qbzr1dyleru.cloudfront.net · ROCA L20 SINK MIXER INStaLLatIoN INStRUCtIoNS Important Note Mixer must be installed to the requirements of AS/NZS 3500 by a

ROCAL20 SINK MIXER

INStaLLatIoN INStRUCtIoNS

sinkbenchtop

*

The aerator with �ow controllerwill be pre assembled and tightenedin the factory.

7

8

14

2

16

15

176

G 1/2”

page 3 of 4

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

Page 4: ROCA L20 SINK MIXER - d12qbzr1dyleru.cloudfront.net · ROCA L20 SINK MIXER INStaLLatIoN INStRUCtIoNS Important Note Mixer must be installed to the requirements of AS/NZS 3500 by a

ROCAL20 SINK MIXER

CLEaNINg INStRUCtIoNS

page 4 of 4

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference


Recommended