TROPICAL ROOFTOPCooling Only - R410a
is a registered trademark of Doğu İklimlendirme A.Ş.
DOGU HVAC founded in 1999, started its activities in order to manufacture HVAC Equipment and Air Handling Units. Now, it manufactures in 3 main groups including HVAC Equipment, HVAC Devices and Kitchen Ventilation according to European norms. DOGU presents all of the products in the device group to the market with the “Four Season” brand. DOGU HVAC operates in 2 plants in Izmir, size of 25.000 m² closed and totally 45.000 m² area with 130 different types of products. In addition to center office, 3 branches in Istanbul, Ankara and Antalya in Turkey and authorized dealers in many countries, are actively working for sales and after sales activities. DOGU HVAC achieved a rapid growth with its strong sales network, more than 250 employees, wide production capacity and advantage of complete certification, adapting the principle of “Customer Satisfaction’’ and “0 Fefect Policy’’. Thus DOGU HVAC presents in more than 40 countries.
DOGU HVAC R&D department developed new products, such as Make-Up Kitchen Hood, Recirculated Laminar Airflow Unit, Single Piece Square Ceiling Diffuser and Ecology Units, and became the first manufacturer of these products in Turkey. DOGU HVAC guaranteed its quality of management by having advantages of ISO 9001, ISO 14001, ISO 18001 certifications. Air Handling Units have EUROVENT, TUV Hygiene (in accordance with DIN 1946-4, VDI 6022-1, DIN EN 13053 standards), CE, TSEK, GOST-R certifications; Fire Dampers have EN 1366-2 and EN 13501-3 CE certifications; Smoke Control Dampers have EN 1366-10 and 12101-8 CE certifications; Kitchen Ventilation Products have TSE, CE and GOST-R quality certifications.
Venues Breathe with DOGU HVAC Systems!
Tropical Rooftop
1. Condenser Fan2. Condenser Fan Motor3. Evaporator Fan4. Evaporator Coil 5. Filter6. Drain Pan7. Condenser Coil
1. Electrical Panel2. Compressor
*”DOGU HVAC” reserves the right to introduce changes of parameters and sizes in the process of improvement of the devices. www.doguhvac.com 1
2
3
4
5
7
1
6
1
2
High efficient scroll compressorMono block UnitAdjustable pulleyAvailable between the range of 18 kW and 151 kWCan be used for cooling and heating with optional electric heaterDesigned to operate at severe ambient temperature up to 52°C without tripping
Evaporator side of all rooftops are internally coated with 25 mm glass wool aluminum foilThe unit is provided with inside control panel for outdoor application (cihaz içinde pano)Coated galvanized steel drain pan The outer skin of the panels is painted standard RAL 9002 coated
G3 class washable filterLow power consumptionEvaporator condenser fans are selected for optimum efficiencyEasy drainageEasy access doors
ROOFTOP GENERAL FEATURES
www.doguhvac.com2 *”DOGU HVAC” reserves the right to introduce changes of parameters and sizes in the process of improvement of the devices.
Tropical Rooftop
1. Casing and Isolation
Evaporator and condenser coils are produced from inner grooved cooper tubes 3/8’’Fin thickness is 0,12 mm suitable for high pressure (R410A)
3. Evaporator and Condenser Coils
Easy access to the electrical panelPhase lossCompressor overload protectionCondenser fan overloadEvaporator fan overloadLoss of refrigeration gasHigh pressure and low pressure switchThermostat
4. Standart Features
Stainless steel drain panBag or compact filterMixing boxElectric heaterDuct sensorCO2 sensorElectronic expansion valveDirty filter indicationFire alarm connectionCoils can be coated by heresite, epoxy or hydrophilic protective coatings.
5. Optional Features
High efficient belt driven DIDW evaporator fanHigh efficient axial condenser fan and low sound level
2. Evaporator and Condenser Fans
*”DOGU HVAC” reserves the right to introduce changes of parameters and sizes in the process of improvement of the devices. www.doguhvac.com 3
Tropical Rooftop
Mixing box with fresh air damper is used in case of fresh air requirement. The amount of fresh air is adjusted by the damper.
5-1. Fresh Air Damper Module
If additional filtration is required, bag or compact filters can be used inside the filter module.
5-1. Bag or Compact Filter Module
www.doguhvac.com4 *”DOGU HVAC” reserves the right to introduce changes of parameters and sizes in the process of improvement of the devices.
Tropical Rooftop
Model TCR-18 TCR-23 TCR-31 TCR-36 TCR-40 TCR-46 TCR-56
Cooling
Condenser Fan
Evaporator Fan
Compressor
Electrical Data
Cooling Capacity (1) (kW)
Power İnput (1) (kW)
Cooling Capacity (2) (kW)
Power İnput (2) (kW)
Cooling Capacity (3) (kW)
Power İnput (3) (kW)
Type
Drive Type
Quantity
Total Airflow (m³/h)
Type
Drive Type
ESP (Pa)
Quantity
Type
Quantity
Power Data
Net Weight (kg)
"Net Dimension (mm)WXLXH"
18,4
6,8
15,4
8,1
13,5
8,9
Axial
Direct
1
3600
Fc Centrifugal
Belt
100
1
Scroll
1
415 V/3 ph/50 hz
390
1110x1604x1387
23,1
9,1
19,2
10,7
16,9
11,7
Axial
Direct
1
5000
Fc Centrifugal
Belt
100
1
Scroll
1
415 V/3 ph/50 hz
410
1410x1604x1387
31,1
11,2
25,7
13,3
22,7
14,6
Axial
Direct
1
5850
Fc Centrifugal
Belt
100
1
Scroll
1
415 V/3 ph/50 hz
470
1410x1382x1595
35,9
12,2
29,9
14,5
26,4
16
Axial
Direct
1
6600
Fc Centrifugal
Belt
100
1
Scroll
1
415 V/3 ph/50 hz
540
1560x1912x1695
40,4
14,2
33,3
17
29,1
18,9
Axial
Direct
1
7800
Fc Centrifugal
Belt
150
1
Scroll
1
415 V/3 ph/50 hz
590
1660x1912x1745
46,3
17,9
38,4
21,1
33,8
23,1
Axial
Direct
2
10000
Fc Centrifugal
Belt
150
1
Scroll
2
415 V/3 ph/50 hz
650
1940x2112x1800
55,4
20,7
46,3
24,2
40,6
26,7
Axial
Direct
2
10750
Fc Centrifugal
Belt
150
1
Scroll
2
415 V/3 ph/50 hz
730
1940x2252x1852
Cooling: (1): Indoor Temperature 26.7°C (80°F) DB / 19.4°C (67°F) WB; - Outdoor Temperature 35°C (95°F) DB. (2): Indoor Temperature 26.7°C (80°F) DB / 19.4°C (67°F) WB; - Outdoor Temperature 46°C (115°F) DB. (3): Indoor Temperature 26.7°C (80°F) DB / 19.4°C (67°F) WB; - Outdoor Temperature 52°C (125°F) DB.
*”DOGU HVAC” reserves the right to introduce changes of parameters and sizes in the process of improvement of the devices. www.doguhvac.com 5
Tropical Rooftop
Model TCR-62 TCR-72 TCR-81 TCR-92 TCR-111 TCR-124 TCR-152
Cooling
Condenser Fan
Evaporator Fan
Compressor
Electrical Data
Cooling Capacity (1) (kW)
Power İnput (1) (kW)
Cooling Capacity (2) (kW)
Power İnput (2) (kW)
Cooling Capacity (3) (kW)
Power İnput (3) (kW)
Type
Drive Type
Quantity
Total Airflow (m³/h)
Type
Drive Type
ESP(Pa)
Quantity
Type
Quantity
Power Data
Net Weight (kg)
"Net Dimension (mm)WXLXH"
62,2
26
51,5
30,1
45,3
32,8
Axial
Direct
2
11500
Fc Centrifugal
Belt
150
1
Scroll
2
415 V/3 ph/50 hz
810
1940x2302x1902
71,8
25,9
59,8
30,5
52,9
33,6
Axial
Direct
2
13300
Fc Centrifugal
Belt
200
1
Scroll
2
415 V/3 ph/50 hz
920
1940x2410x2000
80,8
27,6
66,7
33,2
58,2
37,3
Axial
Direct
2
15000
Fc Centrifugal
Belt
200
1
Scroll
2
415 V/3 ph/50 hz
960
1940x2602x2100
92,5
31,9
77
37,5
67,7
41,5
Axial
Direct
2
16800
Fc Centrifugal
Belt
200
1
Scroll
2
415 V/3 ph/50 hz
1150
2000x2702x2210
110,9
40,7
92,6
47,9
81,2
52,7
Axial
Direct
4
19200
Fc Centrifugal
Belt
300
2
Scroll
4
415 V/3 ph/50 hz
1320
2200x3500x2310
124,4
44,8
102,7
53,3
90,8
58,6
Axial
Direct
4
21400
Fc Centrifugal
Belt
300
2
Scroll
2
415 V/3 ph/50 hz
1420
2250x3500x2410
151,6
56,1
126,5
66
112
72,4
Axial
Direct
4
25200
Fc Centrifugal
Belt
300
2
Scroll
2
415 V/3 ph/50 hz
1750
2300x3500x2510
Cooling: (1): Indoor Temperature 26.7°C (80°F) DB / 19.4°C (67°F) WB; - Outdoor Temperature 35°C (95°F) DB. (2): Indoor Temperature 26.7°C (80°F) DB / 19.4°C (67°F) WB; - Outdoor Temperature 46°C (115°F) DB. (3): Indoor Temperature 26.7°C (80°F) DB / 19.4°C (67°F) WB; - Outdoor Temperature 52°C (125°F) DB.
www.doguhvac.com6 *”DOGU HVAC” reserves the right to introduce changes of parameters and sizes in the process of improvement of the devices.
Tropical Rooftop
Cond
ense
r
Evap
orat
or
High Pressure Switch
Compressor
Low Pressure Switch
Filter Dryer Thermal Expansion Valve
*”DOGU HVAC” reserves the right to introduce changes of parameters and sizes in the process of improvement of the devices. www.doguhvac.com 7
Tropical Rooftop
NOTES
www.doguhvac.com
FactoryİTOB Organize Sanayi Bölgesi 10010 Sk.No: 4 35477 Tekeli, Menderes, İzmir/TURKEYTel: +90 232 799 02 40 Faks: +90 232 799 92 04
2610
2018
İstanbul AreaAğaoğlu My Office Barbaros Mah. Çiğdem Sk.No: 1 Kat: 4/18 Ataşehir, İstanbul/TURKEYTel: +90 216 250 55 45 Faks: +90 216 250 55 46
Ankara AreaLizbon Cad. (Eski 1065 Cad.)No: 55/14 Öveçler, Çankaya, Ankara/TURKEYTel: +90 312 472 11 45 Faks: +90 312 472 11 46