www.coopercontrol.com 1 Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control Proper lighting that emphasizes daylighting with natural light provides a more focused meeting environment. This application illustrates how conference rooms can use daylight dimming in conjunction with natural light entering the space, while providing Scene Control/Automatic Off and receptacle control to achieve energy savings up to 65% and achieve higher quality lighting. Providing optional control of individual lighting zones and HVAC output will allow for even greater energy savings. The Room Controller QuicKit is shipped preconfigured to work out-of-the-box minimizing installation and setup time, while ensuring maximum energy savings. Using this design guide to specify your room with a Room Controller QuicKit catalog number will guarantee that after installation the lighting control system will work immediately as defined on this application guide. SUMMARY ROOM CONTROLLER SAMPLE ROOM LAYOUT (10ʹX15ʹ) Load 1 Dimmer 1 Load 3 Dimmer 3 Load 2 Dimmer 2 Load 2 Dimmer 2 OAWC-DT-120W (Wall Corner Occupancy Sensor) Normal Power Connection RC-6TSB-ZAD-* (Pre-engraved Wallstation) RC-6TSB-CR2-* (Pre-engraved Wallstation) OCC-RJ45 (Connection to any Greengate sensor) DSRC-FMOIR (Multi-zone Daylight Sensor) Zone 3 DN Zone 2 DN Zone 2 UP Zone 1 DN Zone 3 UP Zone 1 UP General All Off Meeting Whiteboard Presentation SPRC-R-20-120 (20A Receptacle Control) Line Voltage to J-Box Emergency Power Connection RC3DE (3 Relay + 3 Dimmer + 1 Emergency) RC3DE Room Controller QuicKit RCQK-OS3E-CR2-ZAD-W1-D1-P-W Scene Control/Automatic Off Individual Zone Raise/Lower control Occupancy based HVAC or Egress control Automatic multi-zone daylight dimming out-of-the-box Automatic Demand Response 10%-40% reduction based on input Receptacle Control for additional energy savings UL 924 emergency relay control High-end trim/tuning to define target light levels After-hours warn Offs and timers to ensure maximum efficiency and savings CONTROL SEQUENCE INTEGRATED CAPABILITIES COOPER LIGHTING GUARANTEED COMPATIBLE FIXTURES Refer to these Cooper Lighting data sheets for lighting layouts and illuminance value information. Corelite LED Room Controller Conference Room Lighting Layouts Corelite LFL Room Controller Conference Room Lighting Layouts Neoray LED Room Controller Conference Room Lighting Layouts Neoray LFL Room Controller Conference Room Lighting Layouts General Meeting Whiteboard Presentation All Off RC-5TSB-CR2-W Conference Room Wallstation 1. All On, Dimmers set to: 100%, 80%, 100% 2. All On, Dimmers set to: 80%, 20%, 100% 3. All On, Dimmers set to: 50%, 100%, 25% 4. All On, Dimmers set to: 30%, 0%, 25% 5. All Off Zone 1 DN Zone 2 UP Zone 2 DN Zone 3 DN Zone 3 UP Zone 1 UP RC-6TSB-ZAD-W Individual Dimming Wallstation 1. Press and hold raise lighting 5% 2. Press and hold lowers lighting 5% 3. Press and hold raise lighting 5% 4. Press and hold lowers lighting 5% 5. Press and hold raise lighting 5% 6. Press and hold lowers lighting 5% UL924 Emergency Demand Response Receptacle Control Daylighting Control Occupancy/Vacancy Sensing Manual Control Integration Product Legend QTY1: RC3DE 3 ON/OFF RELAYS + 3 DIMMERS + 1 EMERGENCY RELAY QTY1: RC-5TSB-CR2-W GENERAL, MEETING, WHITEBOARD, PRESENTATION, ALL OFF QTY:1 RC-6TSB-ZAD-W ZONE 1 UP, ZONE 1 DN, ZONE 2 UP, ZONE 2 DN, ZONE 3 UP, ZONE 3 DN QTY1: DSRC-FMOIR DAYLIGHT SENSOR QTY1: OAWC-DT-120W WALL CORNER MOUNT VACANCY SENSOR QTY1: OCC-RJ45 OCCUPANCY SENSOR RJ45 CONNECTOR QTY1: SPRC-R-20-120 RECEPTACLE CONTROL QTY1: GGRJ45-03-G QUICKCONNECT CABLE 3’ QTY2: GGRJ45-10-G QUICKCONNECT CABLE 10’ QTY3: GGRJ45-25-G QUICKCONNECT CABLE 25’ SINGLE BOX PACKAGING WITH WIRING DETAIL AND INSTALLATION DOWNLIGHT AND SUSPENDED FIXTURES FOR GUARANTEED COMPATIBILITY REFER TO PREFERRED COOPER LIGHTING FIXTURE INFORMATION BELOW. RC3DE
Transcript
Page 1: Room Controller QuicKit Product Legend · 1 Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control Proper lighting that emphasizes daylighting

www.coopercontrol.com

1

Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control

Proper lighting that emphasizes daylighting with natural light provides a more focused meeting environment. This application illustrates how conference rooms can use daylight dimming in conjunction with natural light entering the space, while providing Scene Control/Automatic Off and receptacle control to achieve energy savings up to 65% and achieve higher quality lighting. Providing optional control of individual lighting zones and HVAC output will allow for even greater energy savings.

The Room Controller QuicKit is shipped preconfigured to work out-of-the-box minimizing installation and setup time, while ensuring maximum energy savings. Using this design guide to specify your room with a Room Controller QuicKit catalog number will guarantee that after installation the lighting control system will work immediately as defined on this application guide.

Summary

room Controller Sample room layout (10ʹx15ʹ)

Load 1Dimmer 1

Load 3Dimmer 3

Load 2Dimmer 2

Load 2Dimmer 2

OAWC-DT-120W(Wall Corner Occupancy Sensor)

Normal PowerConnection

RC-6TSB-ZAD-*(Pre-engraved Wallstation)

RC-6TSB-CR2-*(Pre-engraved Wallstation)

OCC-RJ45(Connection to any Greengate sensor)

DSRC-FMOIR(Multi-zone Daylight Sensor)

Zone 3 DN

Zone 2 DN

Zone 2 UP

Zone 1 DN

Zone 3 UP

Zone 1 UPGeneral

All Off

Meeting

Whiteboard

Presentation

SPRC-R-20-120(20A Receptacle Control)

Line Voltageto J-Box

Emergency PowerConnection

RC3DE(3 Relay + 3 Dimmer +1 Emergency)

RC3DE

Room Controller QuicKitRCQK-OS3E-CR2-ZAD-W1-D1-P-W

• Scene Control/Automatic Off

• Individual Zone Raise/Lower control

• Occupancy based HVAC or Egress control

• Automatic multi-zone daylight dimming out-of-the-box

• Automatic Demand Response 10%-40% reduction based on input

• Receptacle Control for additional energy savings

• UL 924 emergency relay control

• High-end trim/tuning to define target light levels

• After-hours warn Offs and timers to ensure maximum efficiency and savings

Control SequenCe

Integrated CapabIlItIeS Cooper lIghtIng guaranteed CompatIble FIxtureS

Refer to these Cooper Lighting data sheets for lighting layouts and illuminance value information.

Corelite LED Room Controller Conference Room Lighting Layouts

Corelite LFL Room Controller Conference Room Lighting Layouts

Neoray LED Room Controller Conference Room Lighting Layouts

Neoray LFL Room Controller Conference Room Lighting Layouts

General

Meeting

Whiteboard

Presentation

All Off

RC-5TSB-CR2-W Conference Room Wallstation

1. All On, Dimmers set to: 100%, 80%, 100%

2. All On, Dimmers set to: 80%, 20%, 100%

3. All On, Dimmers set to: 50%, 100%, 25%

4. All On, Dimmers set to: 30%, 0%, 25%

5. All Off

Zone 1 DN

Zone 2 UP

Zone 2 DN

Zone 3 DN

Zone 3 UP

Zone 1 UP

RC-6TSB-ZAD-W Individual Dimming Wallstation

1. Press and hold raise lighting 5%

2. Press and hold lowers lighting 5%

3. Press and hold raise lighting 5%

4. Press and hold lowers lighting 5%

5. Press and hold raise lighting 5%

6. Press and hold lowers lighting 5%

UL924

Emergency

UL924

DemandResponse

UL924

ReceptacleControl

UL924

DaylightingControl

UL924

Occupancy/VacancySensing

UL924

ManualControl

UL924

Integration

Product Legend

Qty1: RC3DE3 On/Off RElays + 3 DimmERs + 1 EmERgEnCy RElay

Qty1: RC-5tsB-CR2-WgEnERal, mEEting, whitEbOaRD, pREsEntatiOn, all Off

Qty:1 RC-6tsB-zaD-W ZOnE 1 Up, ZOnE 1 Dn, ZOnE 2 Up, ZOnE 2 Dn, ZOnE 3 Up, ZOnE 3 Dn

Qty1: DsRC-FMOIRDaylight sEnsOR

Qty1: OaWC-Dt-120Wwall CORnER mOUnt vaCanCy sEnsOR

Qty1: OCC-RJ45OCCUpanCy sEnsOR RJ45 COnnECtOR

Qty1: sPRC-R-20-120RECEptaClE COntROl

Qty1: GGRJ45-03-GQUiCkCOnnECt CablE 3’

Qty2: GGRJ45-10-GQUiCkCOnnECt CablE 10’

Qty3: GGRJ45-25-GQUiCkCOnnECt CablE 25’

Single box packaging with wiring detail and inStallation

DOWnLIGht anD susPEnDED FIxtuREs

For guaranteed CompatIbIlIty reFer to preFerred Cooper lIghtIng FIxture InFormatIon below.

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

General

Meeting

Whiteboard

Presentation

All Off

Zone 1 DN

Zone 2 UP

Zone 2 DN

Zone 3 DN

Zone 3 UP

Zone 1 UP

Half Lights

All Off

Full Lights

Raise

Lower

RC3DE

Entry Lighting

All Off

RC3D

General

Exam

Reading

All Off

cc

TV

1 2 3

4 5 67 8 9

PREV 0

1 3ALLON/OFF

2

MUTE

SLEEP OPTION

CHANNEL VOLUME

General

Whiteboard

Quiet Time •

A/V Mode

Raise

Lower

Page 2: Room Controller QuicKit Product Legend · 1 Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control Proper lighting that emphasizes daylighting

www.coopercontrol.com

2

The RC3DE will automtically recognize any smart device connected with the QuickConnect cable (provided) and start working immediately upon power up with no programming required. The RC3DE defaults to Manual On/Automatic Off vacancy sensor mode for maximum energy savings. Entry wallstations will provide On/Off control of the Yellow load. Teacher stations provide On/Off control of the Red and Purple loads as well as manual Raise/Lower of all dimmers.

The daylight sensor will automatically, on power up, provide multi-zone daylight dimming in the space. (Remote adjustments can be made later.)

*Refer to Room Controller website for more information on other integral no programming required benefits like Demand Response, Solatube Control, Egress Control, BMS Output, Alert Mode, Emergency Lighting Control, and Slider Stations.

room Controller and Smart devICeS uSe ClICk & go teChnology

QuickConnect coupler (GGRC-COUPLER)

Adjustable daylight sensor dome

Daylight sensor(DSRC-FMOIR)

(OCC-RJ45)

Allows connection to any Greengate Occupancy/Vacancy Sensor

BLACK - Hot(120/277 VAC)

WHT/ORG or WHT/BLKNeutral

BLUE - Relay In(120/277 VAC)

Lighting Load (1)

Lighting Load (2)

Lighting Load (3)

YELLOW

RED

Violet - Dimmer 1

Requires 0-10V dimming ballasts

Gray - Dimmer 1

Gray - Dimmer 2Violet - Dimmer 2

Violet - Dimmer 3Gray - Dimmer 3

Cooper Controls 203 Cooper Circle Peachtree City, GA 30269. USA

Tel: +1-800-553-3879 Fax: +1-800-954-7016 Email: [email protected]: www.coopercontrol.com

Room Controller - RC3DEThree Relay + Three Dimmers Wiring Diagram + One Emergency Relay

Drawing Name: RC3DE-ConferenceReceptacleWC.dwg

PURPLE

Drawing Date: 1/10/2013

*Immediately provides multi-zone daylight dimming upon powerup

BLUE - Emergency Power In(120/277 VAC)

YELLOWEmergency Power OUT

Emergency Lighting Load(Tracks with normal lighting YELLOW load)

EMERGENCY NEUTRAL

120V receptacle circuit

SPRC-R-20-12020A Receptacle Control

Button 5: Load (1),(2),(3) OFF

Button 3: Load (1),(2),(3) ON, Dimmer 1: 50%, Dimmer 2: 100%, Dimmer 3: 25%Button 4: Load (1),(2),(3) ON, Dimmer 1: 30%, Dimmer 2: 0%, Dimmer 3: 25%

Button 2: Load (1),(2),(3) ON, Dimmer 1: 80%, Dimmer 2: 20%, Dimmer 3: 100%

Button 6: Press and hold decrease Zone 3 lighting 5%Button 5: Press and hold increase Zone 3 lighting 5%

Button 3: Press and hold increase Zone 2 lighting 5%Button 4: Press and hold decrease Zone 2 lighting 5%

Button 1: Load (1),(2),(3) ON, Dimmer 1: 100%, Dimmer 2: 80%, Dimmer 3: 100%

RC-5TSB-CR2-*Office Station

Zone 3 DN

Zone 2 DN

Zone 2 UP

Zone 1 DN

Zone 3 UP

Zone 1 UPGeneral

All Off

Meeting

Whiteboard

Presentation

RC-6TSB-ZAD-*Office Station

Button 2: Press and hold decrease Zone 1 lighting 5%Button 1: Press and hold increase Zone 1 lighting 5%

Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts

Dual TechnologyWall Corner Occupancy/Vacancy Sensor(OAWC-DT-120W)*Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings

0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones.

Room Controller and Smart Devices use Click & Go technology:The RC3DE will automtically recognize any smart device connected with the quick connect cable (provided) and start working immediately upon power up with no programming required.The RC3DE defaults to Manual On/Automatic Off vacancy sensor mode for maximum energy savings. Entry wallstations will provide On/Off control of the Yellow load. Teacher stations provide On/Off controll of the Red and Purple loads as well as manual Raise/Lower of all dimmers.The daylight sensor will automatically on power up provide multi-zone daylight dimming in the space. (remote adjustments can be made later) *Refer to Room Controller website for more information on other integral no programming required benefits like Demand Response, Solatube Control, Egress Control, BMS Output, Alert Mode, Emergency Lighting Control, and Slider Stations.

Emergency Note: Emergency load tracks with normal lighting YELLOW load for On/OFF. If dimming it will be adjusted with the dimming zone it is connected to. Upon loss of normal power to the RC3DE, the emergency load will be forced On and full bright to 100%.

In room ladderless testing is done by pressing the "All Off" button four times, within 3 seconds.

The RC3DE is UL 924 listed.

Receptacle Control:20Amp 120 VAC receptacle control immediately works upon power up and connection to the Room Controller.Receptacle turns On by button press or occupancy and Off when space is vacant.

Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control

Page 3: Room Controller QuicKit Product Legend · 1 Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control Proper lighting that emphasizes daylighting

www.coopercontrol.com

3

mountIng the room Controller

wIrIng dIagram

ConneCtIonS

daylight Sensor Ceiling location1. Mount the daylight sensor one to two times the

window height from the window wall.2. Position the sensor so its arrow is pointed toward

the nearest window.3. Ensure the daylight sensor is not obstructed or

looking directly at electric light.4. For narrow spaces mount the daylight sensor near

the window facing into the space.

Sample placement diagram(for example purposes only)

room Controller 0-10v dimming ConnectionsDimmer 1: Near the WindowDimmer 2: Middle of RoomDimmer 3: Far from Window

The daylight sensor will automatically provide multi-zone daylight dimming based on this wiring configuration

room Controller and Smart devices use Click & go Connections1. Wallstations (up to four)2. Slider Station Connection (one)3. Occupancy Sensors (up to two)4. Daylight Sensor (one)5. Receptacle Control or BMS Output6. Switchpack (controlled with Load 1 for

alternate voltage)

60°

Area viewed bydaylight sensor

DaylightSensor

General On

Raise

Lower

Whiteboard

Quiet Time

AV Mode

General On

Off

Entry Wallstation

Room Controller(above entry door)Additional

Wallstation

Wall/Corner Mount Occupancy Sensor

Win

dow

Sample Placement Diagram(for example purposes only)

The Room Controller mounts above the ceiling in the space it is controlling, typically above the door to the room. The Room Controller includes breakouts for direct conduit connection limiting the need for additional junction boxes. Mount the Room Controller using the keyhole slots at the top and secure to the wall using the holes at the bottom of the Room Controller.

Connect conduit to the line voltage breakout connections and connect the line and load wires. Connect low voltage cables either through the low voltage breakout openings or by connecting low voltage conduit to the breakouts on the low voltage side of the Room Controller.

Minor Motion, Ultrasonic

Major Motion, Ultrasonic

Maximum coverage area mayvary somewhat according to room

shape and the presence of obstacles.

The NEMA WD 7 Guide and roboticmethod were utilized to verify

coverage patterns.

24’ (7.3 mm)

Minor Motion, IR

Major Motion, IR

20’ (6 mm)

8’ (2.4 mm)

8’ (2.4 mm)

24’ (7.3 mm)

20’ (6 mm)

0

10 ft(3 mm)

12’ (3.7 mm)

12’ (3.7 mm)

6 ft(1.7 mm)

15 ft(4.6 mm)

24 ft(7.3 mm)

50 ft(15.3 mm)

Minor Motion, Ultrasonic

Major Motion, Ultrasonic

Maximum coverage area mayvary somewhat according to room

shape and the presence of obstacles.

The NEMA WD 7 Guide and roboticmethod were utilized to verify

coverage patterns.

24’ (7.3 mm)

Minor Motion, IR

Major Motion, IR

20’ (6 mm)

8’ (2.4 mm)

8’ (2.4 mm)

24’ (7.3 mm)

20’ (6 mm)

0

10 ft(3 mm)

12’ (3.7 mm)

12’ (3.7 mm)

6 ft(1.7 mm)

15 ft(4.6 mm)

24 ft(7.3 mm)

50 ft(15.3 mm)

Dimmer 3 Dimmer 2 Dimmer 1+ - -+ + -

0-10V Dimming

0-10V Violet (+)0-10V Gray (-)

4325 6

1

Half Lights

All Off

Line Voltageto J-Box

DSRC-FMOIR(Multi-zone

daylight sensor)

Wallstation(Entry)

Full Lights

Raise

Lower

Room Controller(Above Entry Door)

OCC-RJ45

Lower

Raise

Full Lights

Wallstation(Additional)

All Off

Half Lights

SPRC-R-20-120(20A Receptacle Control)

Line Voltageto receptacles

Normal Power(Line In & Load Out)

Emergency Power(Line In & Load Out)

RC3DE model only

0-10V Dimmer Wiring(Dimming Models Only)

(low voltage, class 2)RC3DE

(Any GreengateOccupancy Sensor)

Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control

oCCupanCy SenSor Coverage dIagram (oawC-dt-120w)

Page 4: Room Controller QuicKit Product Legend · 1 Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control Proper lighting that emphasizes daylighting

www.coopercontrol.com

4

orderIng

applICatIonS

rC-3tlb-oS1 rC-5tSb-oS2 rC-6tSb-oS3 rC-2tlb-oS4 rC-6tSb-Cr1

room ControllerQuicKit

types of Space and ControlOS - Office Switching (RC3)

OS2 - Office 2 Zone Dimming (RC3D2)

OS3 - Office 3 Zone Dimming (RC3D)

OS3E - Office 3 Zone Dimming and

and Emergency Relay (RC3DE)

occupancy SensorC1 - Ceiling DT 2000 sq. ft.

C2 - Ceiling PIR 1500 sq. ft.

C3 - Ceiling DT 1000 sq. ft.

W1 - Wall Corner DT

W2 - Wall Corner PIR

W3 - Hallway PIR

daylightD1 - Multi-zone Daylight Sensor

DH - Multi-zone Daylight Sensor w/

Handheld Remote

optionsP - Plug Load

B - BMS/Egress

Station ColorW - White

G - Gray

V - Ivory

B - Black

RCQK - OS3E - CR2 - ZAD - W1 - D1 - P - W

Conference room application button Functionality

programno.

button textControl

type

Function(unless a target level is indicated, the dimmer output

will default to daylight sensor control)

12 General PresetLoad 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ONDimmer 1: 100%, Dimmer 2 80%, Dimmer 3 80%Solatube Open (RC3DE only)

13 Meeting PresetLoad 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ONDimmer 1: 80%, Dimmer 2 20%, Dimmer 3 100%Solatube Open (RC3DE only)

14 Whiteboard PresetLoad 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ONDimmer 1: 50%, Dimmer 2: 100%, Dimmer 3: 50%Solatube Closed (RC3DE only)

15 Presentation PresetLoad 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ONDimmer 1: 30%, Dimmer 2: 0%, Dimmer 3: 25%Solatube Closed (RC3DE only)

6 Raise Raise Raise All Dimmers†

7 Lower Lower Lower All Dimmers†

16 All On PresetLoad 1 (yellow) ON, Load 2 (red) ON Load 3 (purple) ON All Dimmers 100%

8 All Off PresetLoad 1 (yellow) OFF, Load 2 (red) OFF, Load 3 (purple) OFF Solatube closed (RC3DE only)

Slider Slider Raise and Lower All Dimmers††

Half lights

Full lights

All Off

Half Lights

Full Lights

Undercabinet

Raise

Lower

All Off

All On

All Off

General

Meeting

Whiteboard

Presentation

Raise

Lower

Half Lights

Full Lights

Raise

Lower

All Off

Catalog #

Project

Comments

Prepared by

Type

Date

ACC130079

Room Controller - Conference Room w/Daylight Dimming, Receptacle Control and Emergency Control

pre-deFIned wallStatIon model numberS

† These dimming wallstations can only be used with dimming Room Controllers (RC3D, RC3D2, RC3DE)

†† Slider stations can not be used if a wallstation with Raise/Lower buttons are used

*Catalog number automatically includes low voltage connection cable, wallplates and connectors based on room type and configuration.

*For site specific engraving, please see the Room Controller Wallstation custom engraving form on the Cooper Controls website

rC-5tSb-Cr2

General

Meeting

Whiteboard

Presentation

All Off

rC-6tSb-Zad

Zone 1 DN

Zone 2 UP

Zone 2 DN

Zone 3 DN

Zone 3 UP

Zone 1 UP

office Stations (Choose up to 4)OS1 - Half Lights, Full Lights, All Off

(3 Large Buttons)

OS2 - Half Lights, Full Lights, Raise, Lower, All Off †

(5 Small Buttons)

OS3 - Half Lights, Full Lights, Under Cabinet, Raise, Lower, All Off †

(6 Small Buttons)

OS4 - All On, All Off (2 Large Buttons)

CR1 - General, Meeting, Whiteboard, Presentation, Raise, Lower

(6 Small Buttons - Scenes)

CR2 - General, Meeting, Whiteboard, Presentation, All Off

(5 Small Buttons - Scenes)

SS1 - Slider Station ††

ZAD - Zone 1 UP, Zone 2 DN, Zone 3 UP, Zone 3 DN

(6 Small Buttons - Scenes)


Recommended