www.belimo.com T5-NR230A-S • en • v1.0 • 03.2009 • Subject to changes 1 / 3 Technical data sheets NR230A-S Rotary actuator for 2- and 3-way (control) ball valves • Torque 10 Nm • Nominal voltage AC 100 ... 240 V • Control: Open/close or 3-point • with auxiliary switch Technical data Electrical data Nominal voltage AC 100 ... 240 V, 50/60 Hz Nominal voltage range AC 85 ... 265 V Power consumption In operation At rest For wire sizing 2.5 W @ nominal torque 0.4 W 5.5 VA Auxiliary switch 1 x SPDT, 1 mA ... 3 (0.5) A, AC 250 V II (0 ... 100% adjustable) Connection Motor Auxiliary switch Cable 1 m, 3 x 0.75 mm 2 Cable 1 m, 3 x 0.75 mm 2 Parallel connection Possible, note performance data Functional data Torque (nominal torque) Min. 10 Nm @ nominal voltage Manual override Gearing latch disengaged with pushbutton, can be locked Running time 90 s / 90° Sound power level Max. 35 dB (A) (without the valve) Position indication Mechanical, pluggable Safety Protection class II totally insulated Degree of protection IP54 in any mounting position NEMA 2, UL Enclosure Type 2 EMC Low-voltage directive CE according to 2004/108/EC CE according to 2006/95/EC Certification cULus according to UL 60730-1A and UL 60730-2-14 and CAN/CSA E60730-1:02 Certified to IEC/EN 60730-1 and IEC/EN 60730-2-14 Mode of operation Type 1 Rated impulse voltage 2.5 kV Control pollution degree 3 Ambient temperature 0 ... +50°C Media temperature +5 ... +110°C in (control) ball valve –10°C with stem heating upon request Non-operating temperature –40 ... +80°C Ambient humidity 95% r.H., non-condensating Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page 3 Weight Approx. 800 g
Transcript

www.belimo.com T5-NR230A-S • en • v1.0 • 03.2009 • Subject to changes 1 / 3

Technical data sheets NR230A-S

Rotary actuator for 2- and 3-way (control) ball valves• Torque 10 Nm• Nominal voltage AC 100 ... 240 V• Control: Open/close or 3-point• with auxiliary switch

Technical data

Electrical data Nominal voltage AC 100 ... 240 V, 50/60 HzNominal voltage range AC 85 ... 265 VPower consumption In operation

At restFor wire sizing

2.5 W @ nominal torque0.4 W5.5 VA

Auxiliary switch 1 x SPDT, 1 mA ... 3 (0.5) A, AC 250 V II (0 ... 100% adjustable)

Connection MotorAuxiliary switch

Cable 1 m, 3 x 0.75 mm2

Cable 1 m, 3 x 0.75 mm2

Parallel connection Possible, note performance data

Functional data Torque (nominal torque) Min. 10 Nm @ nominal voltageManual override Gearing latch disengaged with pushbutton, can be lockedRunning time 90 s / 90°Sound power level Max. 35 dB (A) (without the valve)Position indication Mechanical, pluggable

Safety Protection class II totally insulated Degree of protection IP54 in any mounting position

NEMA 2, UL Enclosure Type 2EMCLow-voltage directive

CE according to 2004/108/ECCE according to 2006/95/EC

Certification cULus according to UL 60730-1A and UL 60730-2-14and CAN/CSA E60730-1:02Certified to IEC/EN 60730-1 and IEC/EN 60730-2-14

Mode of operation Type 1Rated impulse voltage 2.5 kVControl pollution degree 3Ambient temperature 0 ... +50°CMedia temperature +5 ... +110°C in (control) ball valve

–10°C with stem heating upon requestNon-operating temperature –40 ... +80°CAmbient humidity 95% r.H., non-condensatingMaintenance Maintenance-free

Dimensions / Weight Dimensions See «Dimensions» on page 3Weight Approx. 800 g

NR230A-S Rotary actuator, AC 100 ... 240 V, 10 Nm, with auxiliary switch, for 2- and 3-way (control-) ball valves

2 / 3 T5-NR230A-S • en • v1.0 • 03.2009 • Subject to changes www.belimo.com

Safety notes

!• The actuator has been designed for use in stationary heating, ventilation and air conditioning

systems and is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport.

• Caution: Power supply AC 230 V !• It may only be installed by suitably trained personnel.

All applicable legal or institutional installation regulations must be complied with.• The switch for changing the direction of rotation may only be operated by authorized

personnel. The direction of rotation must not be reversed in a frost protection circuit.• The device may only be opened at the manufacturer's site. It does not contain any parts that

can be replaced or repaired by the user.• The cable must not be removed from the device.• The device contains electrical and electronic components and is not allowed to be disposed

of as household refuse. All locally valid regulations and requirements must be observed.

Accessories

Description Data sheet

Electrical Accessories Auxiliary switch S..A.. T2 - S..A..Feedback potentiometer P..A.. T2 - P..A..

Electrical installation

Wiring diagrams Open-close control 3-point control

Notes• Caution: Power supply AC 230 V !• Parallel connection of other actuators possible.

Note performance data.• Direction of rotation switch is covered.

Factory setting: Direction of rotation Y2.

!

1 2 3

0 ... 100%

S1 S2 S3S3

Y2

N L

Cabel colours:1=blue2=braun3=whiteS1=violetS2=redS3=white

Actuator valveY2 A – AB = 0%

1 2 3

0 ... 100%

S1 S2 S3

0

Y2 Y1

N L

Direction of rotationY2

Y1

Auxiliary switch 1

0

S1 S2 S31

0

S1 S2 S31

0

Product features

Simple direct mounting Straightforward direct mounting on the ball valve with only one screw. The assembly tool is integrated in the plug-on position indicator. The mounting position in relation to the ball valve can be selected in 90° steps.

Manual override Manual override with push-button possible (the gear is disengaged for as long as the button is pressed or remains locked).

Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.

High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached.

Flexible signalization Flexible signalization with adjustable auxiliary switch (0 ... 100%).

NR230A-S Rotary actuator, AC 100 ... 240 V, 10 Nm, with auxiliary switch, for 2- and 3-way (control-) ball valves

www.belimo.com T5-NR230A-S • en • v1.0 • 03.2009 • Subject to changes 3 / 3

Dimensions [mm]

Dimensional drawings

86

10865

83

9928 41

R 65

86

10865

83

9928 41

R 65

Further documentations • Complete overview «The comlete range of water solutions»• Data sheets for control ball valves• Installation instructions for actuators and/or control ball valves• Notes for project planning (hydraulic characteristic curves and circuits, installation regulations,

commissioning, maintenance etc.)

TR..A../LR..A../NR..A../SR..A..

www.belimo.com M5-TR..A../LR..A../NR..A../SR..A.. • v2.2 • 12.2009 1 / 2

7074

1-00

001.

C

1 2

1

AB

A

A – AB = 100%B – AB = 0%

A

ABB

A – AB = 100%

A – AB = 100%

2

4

5

3

1

2

TR..A../LR..A../NR..A../SR..A..

2 / 2 M5-TR..A../LR..A../NR..A../SR..A.. • v2.2 • 12.2009 www.belimo.com

AC24V/DC24V

1 32 5

– +

T ~ Y DC (0) 2 ... 10 V

U DC 2 ... 10 V

1 32 5

– +

T ~ Y DC (0) 2 ... 10 V

U MP

TRC24A-SR LR24A-MFLR(C)24A-SR NR24A-MFNR(C)24A-SR SR24A-MFSR24A-SR

LR24A-MPNR24A-MPSR24A-MP

N L1

1 2 3

Y2

– +

T ~

1 2 3

0

Y1Y2

N L1

– +

T ~

AC24V/DC24V

1 2 3

– +

T ~

+

~

1 2 3

0...100%

S1 S2 S3

– +

T ~

+

~

LR24ANR24ASR24A

LR24A-SNR24A-SSR24A-S

AC100...240V N L1 L1

1 2 3

N L1 L1

1 2 3

0...100%

S1 S2 S3S1 S2 S3

1

0

S1 S2 S31

0

LR230A NR230ASR230A

LR230A-S NR230A-SSR230A-S

!

LONWORKS® AC24V/DC24V

5 6 7321

MF

T

LO

N

LO

N

T ~

V

5 6 7321

MF

T

LO

N

LO

N

+–

T ~

5 6 7321

MFT

LON

LON

+–

T ~

∆p

5 6 7321

MF

T

LO

N

LO

N

+–

T ~

Y2

Y1


Recommended