CODE INFORMATION APPLICABLE CODES THE CODE ANALYSIS OF THIS PROJECT HAS BEEN BASED ON THE FOLLOWING CODES. UNIFORM CONSTRUCTION CODE, STATE OF NEW JERSEY REHABILITATION SUBCODE- NJAC 5: 23-6 BARRIER FREE SUBCODE- NJAC 5: 23-7 INTERNATIONAL BUILDING CODE- NEW JERSEY EDITION, 2015 NATIONAL ELECTRICAL CODE, 2014 NATIONAL STANDARD PLUMBING CODE, 2015 ASHRAE 90.1, 2013 INTERNATIONAL MECHANICAL CODE, 2015 INTERNATIONAL FUEL GAS CODE, 2015 ANSI A117.1-2009 PROJECT SCOPE: THE WORK TO BE PERFORMED IN THIS PROJECT INCLUDES: THE RENOVATION OF THREE EXISTING BATHROOMS ON THE 1ST, 2ND, & 3RD FLOOR INCLUDING FIXTURE AND PIPING REPLACEMENT. CODE ANALYSIS: A. USE AND OCCUPANCY CLASSIFICATION: USE GROUP 'R-2' USE AND OCCUPANCY CLASSIFICATION: USE GROUP 'R-2' THERE WILL BE NO CHANGE TO THE BUILDING'S USE OR OCCUPANCY DUE TO THE PROPOSED WORK. CONSTRUCTION CLASSIFICATION: TYPE 'IIB' THERE WILL BE NO CHANGE TO THE BUILDING'S CONSTRUCTION CLASSIFICATION DUE TO THE PROPOSED WORK. C. CATEGORY OF WORK PER THE REHABILITATION SUBCODE- NJAC 5:23-6 CATEGORY OF WORK PER THE REHABILITATION SUBCODE- NJAC 5:23-6 THE WORK PROPOSED FOR THIS PROJECT IS CLASSIFIED AS AN ALTERATION: - PER NJAC 5:23-6.6(E) THE FOLLOWING PRODUCTS AND PRACTICES SHALL BE REQUIRED, WHEN APPLICABLE: 1. WHEN ANY WATER CLOSET IS REPLACED, THE REPLACEMENT WATER CLOSET SHALL REQUIRE NOT MORE THAN 1.6 WHEN ANY WATER CLOSET IS REPLACED, THE REPLACEMENT WATER CLOSET SHALL REQUIRE NOT MORE THAN 1.6 GALLONS OF WATER PER FLUSH AS REQUIRED BY THE PLUMBING SUBCODE. (PLUMBING) 2. IN BUILDINGS REQUIRED BY CHAPTER 11 OF THE BUILDING SUBCODE TO BE ACCESSIBLE, WHEN BATHROOMS OR IN BUILDINGS REQUIRED BY CHAPTER 11 OF THE BUILDING SUBCODE TO BE ACCESSIBLE, WHEN BATHROOMS OR TOILET ROOMS ARE ALTERED, THE FOLLOWING REQUIREMENTS FOR PROVIDING ACCESSIBILITY SHALL APPLY UNLESS THE REQUIREMENTS OF CHAPTER 11 OF THE BUILDING SUBCODE HAVE BEEN MET: IV.) WHERE IT IS TECHNICALLY INFEASIBLE TO GAIN COMPLIANCE WITH THE ALTERED BATHROOM, SIGNAGE WHERE IT IS TECHNICALLY INFEASIBLE TO GAIN COMPLIANCE WITH THE ALTERED BATHROOM, SIGNAGE TO THE CLOSEST ACCESSIBLE BATHROOM (IF ANY) SHALL BE PROVIDED AT THE ALTERED BATHROOM. (BUILDING) 3. IN BUILDINGS REQUIRED BY CHAPTER 11 OF THE BUILDING SUBCODE TO BE ACCESSIBLE, WHEN SPACE IS IN BUILDINGS REQUIRED BY CHAPTER 11 OF THE BUILDING SUBCODE TO BE ACCESSIBLE, WHEN SPACE IS RECONFIGURED, THE ALTERED SPACE SHALL COMPLY WITH CHAPTER 11 OF THE BUILDING SUBCODE. WHERE FULL COMPLIANCE IS TECHNICALLY INFEASIBLE, COMPLIANCE SHALL BE ACHIEVED TO THE MAXIMUM EXTENT FEASIBLE. (BUILDING) COMPLIANCE SHALL BE ACHIEVED TO THE GREATEST EXTENT FEASIBLE WITH THE NEW FIXTURES. CLEARANCE REQUIRED AT FIXTURES CAN NOT BE PROVIDED WITHOUT DEMOLISHING EXISTING MASONRY BEARING WALLS AND ENLARGING THE EXISTING BATHROOMS. ALL FLOORS OF THE EXISTING DORMITORY ARE NOT SERVED BY AN ACCESSIBLE ROUTE. NONE OF THE EXISTING DORMITORY DOORS ARE ACCESSIBLE. D. FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS. FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS. PER NJAC 5:23-6.25(K) VERTICAL OPENINGS WILL BE PROTECTED WITH A ONE HOUR UFC FIRE BARRIER. E. INTERIOR WALL AND CEILING REQUIREMENTS-BY OCCUPANCY (PER IBC 2015- NJ, TABLE 803.9) INTERIOR WALL AND CEILING REQUIREMENTS-BY OCCUPANCY (PER IBC 2015- NJ, TABLE 803.9) EXISTING TO REMAIN. F. OCCUPANT LOAD. OCCUPANT LOAD. EXISTING TO REMAIN. G. MEANS OF EGRESS. MEANS OF EGRESS. THERE WILL BE NO CHANGE TO THE EXISTING MEANS OF EGRESS. H. PLUMBING FIXTURE COUNTS. PLUMBING FIXTURE COUNTS. THERE WILL BE NO CHANGE IN THE NUMBER OF PLUMBING FIXTURES AS PART OF THIS PROJECT.
AutoCAD SHX Text
A-200
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
A
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
5/03/2019
AutoCAD SHX Text
LF
AutoCAD SHX Text
TR, TDLR
AutoCAD SHX Text
A
AutoCAD SHX Text
5/03/19
AutoCAD SHX Text
ISSUED FOR BID / CONSTRUCTION
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
A-1100
AutoCAD SHX Text
FINISH PLANS AND SCHEDULE
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
P-100
AutoCAD SHX Text
PLUMBING PLANS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
M-100
AutoCAD SHX Text
HVAC PLAN AND SCHEDULES
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
GENERAL NOTES: UNLESS OTHERWISE NOTED, GENERAL NOTES REFER TO ALL TYPICAL CONDITIONS THROUGHOUT THE BUILDING. 1. THESE DRAWINGS REPRESENT AN OVERALL DESIGN CONCEPT. THEY ARE PREPARED WITH THE INTENT TO DEMONSTRATE AN OVERALL DESIGN ARRANGEMENT OF THESE DRAWINGS REPRESENT AN OVERALL DESIGN CONCEPT. THEY ARE PREPARED WITH THE INTENT TO DEMONSTRATE AN OVERALL DESIGN ARRANGEMENT OF THE VARIOUS COMPONENTS OF THE ENTIRE PROJECT. THE CONTRACTOR IS ASSUMED TO HAVING REVIEWED THESE DRAWINGS, AND HAVING SEEN THE SUBJECT PROPERTY, IS CAPABLE OF EXECUTING THE DETAIL WORK NECESSARY TO ACHIEVE THE INTENDED RESULTS IN A MANNER THAT IS CONSISTENT WITH THE QUALITY WORKMANSHIP IN THE REGION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW THE DRAWINGS, VISIT THE SITE, VERIFY THE EXISTING CONDITIONS, DIMENSIONS, CLEARANCES, Etc., SHOWN ON THE DRAWINGS PRIOR TO BIDDING. 2. THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND SHALL NOT BE USED FOR A BUILDING PERMIT UNLESS SIGNED AND SEALED BY THE THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND SHALL NOT BE USED FOR A BUILDING PERMIT UNLESS SIGNED AND SEALED BY THE ARCHITECT. 3. THE OWNER AND CONTRACTOR SHALL HOLD THE ARCHITECT HARMLESS AGAINST ANY CLAIMS, DAMAGES, LOSSES AND EXPENSES INCLUDING ATTORNEY FEES THE OWNER AND CONTRACTOR SHALL HOLD THE ARCHITECT HARMLESS AGAINST ANY CLAIMS, DAMAGES, LOSSES AND EXPENSES INCLUDING ATTORNEY FEES ARISING OR RESULTING FROM THE PERFORMANCE OF THE WORK BY THE CONTRACTOR. 4. THE ARCHITECT IS NOT RESPONSIBLE WHERE CONSTRUCTION DEVIATES FROM PLANS UNLESS APPROVED IN WRITING BY THE ARCHITECT. THE ARCHITECT IS NOT RESPONSIBLE WHERE CONSTRUCTION DEVIATES FROM PLANS UNLESS APPROVED IN WRITING BY THE ARCHITECT. 5. REPRODUCTIONS OF CONTRACT DOCUMENTS ARE NOT ACCEPTABLE AS SHOP DRAWINGS AND WILL BE REJECTED. REPRODUCTIONS OF CONTRACT DOCUMENTS ARE NOT ACCEPTABLE AS SHOP DRAWINGS AND WILL BE REJECTED. 6. CONTRACTOR TO SUBMIT STAGING PLANS AND CONSTRUCTION SCHEDULE FOR ARCHITECT'S AND OWNER'S REVIEW PRIOR TO COMMENCING WORK. CONTRACTOR TO SUBMIT STAGING PLANS AND CONSTRUCTION SCHEDULE FOR ARCHITECT'S AND OWNER'S REVIEW PRIOR TO COMMENCING WORK. 7. ALL EQUIPMENT AND WORKING HOURS MUST MEET LOCAL ORDINANCES. ALL EQUIPMENT AND WORKING HOURS MUST MEET LOCAL ORDINANCES. 8. UNLESS NOTED OTHERWISE, ALL NEW ITEMS SHALL BE FURNISHED BY THE GENERAL CONTRACTOR. UNLESS NOTED OTHERWISE, ALL NEW ITEMS SHALL BE FURNISHED BY THE GENERAL CONTRACTOR. 9. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCY OR DEVIATION BETWEEN DRAWGINS AND ANY FIELD VERIFIED CONDITIONS PRIOR TO COMMENCING WORK. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCY OR DEVIATION BETWEEN DRAWGINS AND ANY FIELD VERIFIED CONDITIONS PRIOR TO COMMENCING WORK. 10. IF ANY DISCREPANCIES BETWEEN DWGS AND SPECIFICATIONS EXIST, THE MORE STRINGENT SHALL TAKE PRECEDENCE. SIMILARLY BETWEEN ARCHITECTURAL IF ANY DISCREPANCIES BETWEEN DWGS AND SPECIFICATIONS EXIST, THE MORE STRINGENT SHALL TAKE PRECEDENCE. SIMILARLY BETWEEN ARCHITECTURAL PLANS AND VARIOUS ENGINEERING DISCIPLINES. 11. DO NOT SCALE DRAWINGS. ALL MEASUREMENTS MUST BE CONFIRMED IN THE FIELD. DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. IF A DIMENSION IS DO NOT SCALE DRAWINGS. ALL MEASUREMENTS MUST BE CONFIRMED IN THE FIELD. DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. IF A DIMENSION IS UNCLEAR OR A DISCREPANCY IS FOUND, NOTIFY THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 12. ALL CONTRACTORS TO VERIFY ALL DIMENSIONS AND QUANTITIES PRIOR TO ORDERING, FABRICATING OR CONSTRUCTING ANY PART OF THE PROJECT. NOTIFY ALL CONTRACTORS TO VERIFY ALL DIMENSIONS AND QUANTITIES PRIOR TO ORDERING, FABRICATING OR CONSTRUCTING ANY PART OF THE PROJECT. NOTIFY ARCHITECT IMMEDIATELY WITH ANY AND ALL DISCREPANCIES. 13. PROVIDE DUST CONTROL AS REQUIRED. SEE SPECIFICATIONS FOR MORE INFORMATION, TYP. PROVIDE DUST CONTROL AS REQUIRED. SEE SPECIFICATIONS FOR MORE INFORMATION, TYP. 14. NOTIFY OWNER/ARCHITECT 72 HOURS MINIMUM IN ADVANCE OF ANY UTILITY SHUT-OFFS. NOTIFY OWNER/ARCHITECT 72 HOURS MINIMUM IN ADVANCE OF ANY UTILITY SHUT-OFFS. 15. UTILIZE OSHA SAFETY PRECAUTIONS AS REQUIRED. CONTRACTOR TO PROVIDE OWNER/ARCHITECT WITH COPIES OF ALL MINUTES/SIGN-IN SHEETS FOR "TOOL UTILIZE OSHA SAFETY PRECAUTIONS AS REQUIRED. CONTRACTOR TO PROVIDE OWNER/ARCHITECT WITH COPIES OF ALL MINUTES/SIGN-IN SHEETS FOR "TOOL BOX" TALKS ON A MONTHLY BASIS. SUBMISSION IS A CONDITION OF RELEASE OF PAYMENT. 16. GENERAL CONTRACTOR TO COORDINATE WITH OTHER CONTRACTORS ON SITE HIRED UNDER SEPARATE CONTRACT. GENERAL CONTRACTOR TO COORDINATE WITH OTHER CONTRACTORS ON SITE HIRED UNDER SEPARATE CONTRACT. 17. INSTALL ALL FIXTURES, MATERIALS, AND FINISHES IN STRICT COMPLIANCE WITH MANUFACTURER'S TECHNICAL SPECIFICATIONS, TYP. INSTALL ALL FIXTURES, MATERIALS, AND FINISHES IN STRICT COMPLIANCE WITH MANUFACTURER'S TECHNICAL SPECIFICATIONS, TYP. 18. FOR PROJECTS LOCATED IN NEW JERSEY, THE CONTRACTOR MUST CALL 1-800-272-1000 PRIOR TO THE START OF ANY SITE EXCAVATION TO HELP LOCATE FOR PROJECTS LOCATED IN NEW JERSEY, THE CONTRACTOR MUST CALL 1-800-272-1000 PRIOR TO THE START OF ANY SITE EXCAVATION TO HELP LOCATE EXISTING UNDERGROUND UTILITIES. 19. ALL CODES HAVING JURISDICTION SHALL BE OBSERVED STRICTLY IN THE CONSTRUCTION OF THE PROJECT, INCLUDING ALL APPLICABLE STATE, CITY, AND ALL CODES HAVING JURISDICTION SHALL BE OBSERVED STRICTLY IN THE CONSTRUCTION OF THE PROJECT, INCLUDING ALL APPLICABLE STATE, CITY, AND COUNTY BUILDING, ZONING, ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE CODES. THE CONTRACTOR SHALL VERIFY ALL CODE REQUIREMENTS BEFORE COMMENCEMENT OF CONSTRUCTION AND BRING ANY DISCREPANCIES BETWEEN CODE REQUIREMENTS AND THE CONSTRUCTION DOCUMENTS TO THE ATTENTION OF THE ARCHITECT. 20. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED IN A SIMILAR FASHION OR BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. MODIFICATIONS MAY BE REQUIRED BY THE CONTRACTOR TO ACCOMMODATE FOR MINOR VARIATIONS. 21. ALL WALLS SHALL BE BRACED DURING CONSTRUCTION UNTIL PERMANENTLY RESTRAINED. ALL WALLS SHALL BE BRACED DURING CONSTRUCTION UNTIL PERMANENTLY RESTRAINED. 22. INSTALL TEMPORARY SHORING AND BRACING AND MAKE SAFE ALL WALLS, CEILINGS, AND DOORS AS REQUIRED. INSTALL TEMPORARY SHORING AND BRACING AND MAKE SAFE ALL WALLS, CEILINGS, AND DOORS AS REQUIRED. 23. MAINTAIN PROTECTED EGRESS AND ACCESS TO WORK. CONTRACTOR TO ENSURE THAT ALL PUBLIC SIDEWALKS, ROADWAYS, MEANS OF EGRESS, CORRIDORS, MAINTAIN PROTECTED EGRESS AND ACCESS TO WORK. CONTRACTOR TO ENSURE THAT ALL PUBLIC SIDEWALKS, ROADWAYS, MEANS OF EGRESS, CORRIDORS, ETC. ARE MAINTAINED DURING CONSTRUCTION AT ALL TIMES. CONTRACTOR TO PROVIDE SIDEWALK BRIDGING, NETTING AND ANY OTHER MEANS REQUIRED TO PROTECT ALL PEDESTRIANS AT THE EXTERIOR OF THE BUILDING. 24. ALL PENETRATIONS SHALL BE FIRESTOPPED, WHEN THEY PASS THRU FLOOR/CEILING ASSEMBLIES OR THRU RATED WALL CONSTRUCTION. ALL PENETRATIONS SHALL BE FIRESTOPPED, WHEN THEY PASS THRU FLOOR/CEILING ASSEMBLIES OR THRU RATED WALL CONSTRUCTION. 25. THE CONTRACTOR WILL BE FULLY RESPONSIBLE FOR PROTECTING ALL ROOF SURFACES FROM DAMAGE DURING THE PROJECTS DURATION. IT WILL THE THE CONTRACTOR WILL BE FULLY RESPONSIBLE FOR PROTECTING ALL ROOF SURFACES FROM DAMAGE DURING THE PROJECTS DURATION. IT WILL THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY DAMAGE TO THE ROOFS IN A MANNER ACCEPTABLE TO THE OWNER WHILE MAINTAINING ALL ROOFING WARRANTIES. 26. CONTRACTOR TO PREVENT CONSTRUCTION DUST AND DEBRIS FROM ENTERING THE BUILDING. CONTRACTOR TO PROVIDE AND INSTALL TRANSPARENT PLASTIC CONTRACTOR TO PREVENT CONSTRUCTION DUST AND DEBRIS FROM ENTERING THE BUILDING. CONTRACTOR TO PROVIDE AND INSTALL TRANSPARENT PLASTIC BARRIERS AS REQUIRED ADJACENT TO CONSTRUCTION ACTIVITIES TO PREVENT CONSTRUCTION DUST FROM ENTERING THE BUILDING. 27. GENERAL CONTRACTOR MUST COORDINATE LOCATION PIPING, ELECTRICAL DEVICES, OUTLETS, THERMOSTATS, ETC. WITH EXISTING CONDITIONS AND WORK OF GENERAL CONTRACTOR MUST COORDINATE LOCATION PIPING, ELECTRICAL DEVICES, OUTLETS, THERMOSTATS, ETC. WITH EXISTING CONDITIONS AND WORK OF OTHER TRADES. 28. INSTALL EXPOSED ELECTRIC, MECHANICAL AND PLUMBING SYSTEMS, MATERIALS AND EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER INSTALL EXPOSED ELECTRIC, MECHANICAL AND PLUMBING SYSTEMS, MATERIALS AND EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER SYSTEMS AND COMPONENTS WHERE INSTALLED IN EXPOSED UNFINISHED SPACES. DIAGONAL RUNS ARE PROHIBITED. 29. ALL THROUGH PENETRATIONS SHALL BE PATCHED, SEALED, AND FIRE STOPPED AS REQUIRED. REPAIR ALL ADJACENT SURFACES AS REQUIRED TO MATCH ALL THROUGH PENETRATIONS SHALL BE PATCHED, SEALED, AND FIRE STOPPED AS REQUIRED. REPAIR ALL ADJACENT SURFACES AS REQUIRED TO MATCH EXISTING. 30. PROPERLY TEST, BALANCE, AND ADJUST ALL EQUIPMENT AND SYSTEMS USED IN THE PROCESS OF COMPLETING THE SCOPE OF WORK. PROPERLY TEST, BALANCE, AND ADJUST ALL EQUIPMENT AND SYSTEMS USED IN THE PROCESS OF COMPLETING THE SCOPE OF WORK. 31. CONTRACTOR WILL BE FULLY RESPONSIBLE FOR REPLACING DAMAGED LANDSCAPING, LAWN AREAS, AND SIDEWALKS DAMAGED DURING CONSTRUCTION.CONTRACTOR WILL BE FULLY RESPONSIBLE FOR REPLACING DAMAGED LANDSCAPING, LAWN AREAS, AND SIDEWALKS DAMAGED DURING CONSTRUCTION.
AutoCAD SHX Text
A-700
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
G-002
AutoCAD SHX Text
PARTITION TYPES
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
P-200
AutoCAD SHX Text
PLUMBING PLANS
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
E-100
AutoCAD SHX Text
ELECTRICAL PLANS AND SCHEDULES
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
SCHEDULE OF ADD ALTERNATES ADD ALTERNATE NO. 01: KITCHEN CABINETS, COUNTERTOP, PLUMBING FIXTURE, AND LIGHT FIXTURES ROOM# 119B. KITCHEN CABINETS, COUNTERTOP, PLUMBING FIXTURE, AND LIGHT FIXTURES ROOM# 119B. BASE BID: DEMOLISH EXISTING CONCRETE FLOOR, FLOOR FINISH, WALL BASE, CABINETS, BACK SPLASH, OVEN/RANGE, SINK, ASSOCIATED PIPING, AND UNDER CABINET LIGHT FIXTURE IN KITCHEN 119B. PROVIDE NEW CONCRETE, FLOORING, AND VINYL WALL BASE. PAINT WALLS, CEILING, AND SOFFIT ACCORDING TO THE FINISH PLAN. PROVIDE PLUMBING STUB OUTS FOR FUTURE KITCHEN SINK AND CAP. TERMINATE EXISTING ELECTRIC FOR THE UNDER CABINET LIGHT FIXTURE AT A NEW WALL MOUNTED JUNCTION BOX. ALTERNATE: DEMOLISH THE EXISTING CEILING MOUNTED LIGHT FIXTURE. PROVIDE NEW WALL CABINETS, BASE CABINETS, COUNTERTOP, KITCHEN SINK, UNDER CABINET LIGHT FIXTURE, AND CEILING MOUNTED LIGHT FIXTURE IN ACCORDANCE WITH THE PROJECT DOCUMENTS.
1. PARTITIONS DIMENSIONED TO FACE OF GYPSUM / CEMENT BOARD, U.O.N. PARTITIONS DIMENSIONED TO FACE OF GYPSUM / CEMENT BOARD, U.O.N. 2. SEAL ALL PIPE, DUCT AND AIR SHAFTS WITH ACOUSTICAL SEALANT AND FIRE-RATED SEAL ALL PIPE, DUCT AND AIR SHAFTS WITH ACOUSTICAL SEALANT AND FIRE-RATED ACOUSTICAL SEALANT WHERE REQUIRED. PROVIDE CLEAN CUT THROUGH GWB PARTITION AND PROVIDE CLEAN SEAL. 3. DUCTS, PIPES OR OTHER WALL PENETRATIONS THAT INTERRUPT STUDS ARE TO BE COMPLETLY DUCTS, PIPES OR OTHER WALL PENETRATIONS THAT INTERRUPT STUDS ARE TO BE COMPLETLY FRAMED AROUND WITH 1" GAP AROUND PENETRATING ELEMENT. GAP TO BE FILLED WITH ACOUSTICAL INSULATION. 4. PROVIDE PLACARDS FOR RATED ASSEMBLIES ABOVE CEILINGS AND WITHIN CONCEALED SPACES. PROVIDE PLACARDS FOR RATED ASSEMBLIES ABOVE CEILINGS AND WITHIN CONCEALED SPACES. 5. CONTRACTOR IS RESPONSIBLE FOR VERIFYING & COORDINATING WALL AND DOOR FRAMES THAT CONTRACTOR IS RESPONSIBLE FOR VERIFYING & COORDINATING WALL AND DOOR FRAMES THAT REQUIRE A NON-TYPICAL WALL THICKNESS DUE TO EXISTING CONDITIONS, STRUCTURAL, ELECTRICAL, MECHANICAL, AND EQUIPMENT REQUIREMENTS. 6. CONTRACTOR SHALL VERIFY ALL MOUNTING HEIGHTS AND SPECIAL STRUCTURAL SUPPORT CONTRACTOR SHALL VERIFY ALL MOUNTING HEIGHTS AND SPECIAL STRUCTURAL SUPPORT REQUIREMENTS WITH EQUIPMENT, DEVICE, AND CASEWORK MANUFACTURERS BEFORE INSTALLING BACKING BLOCKS AND SUPPORTS. 7. ALL PARTITIONS SHALL EXTEND TO UNERSIDE OF DECK ABOVE U.O.N. ALL PARTITIONS SHALL EXTEND TO UNERSIDE OF DECK ABOVE U.O.N. 8. FIRE BLOCKING AND DRAFT STOPPING SHALL BE INSTALLED IN COMBUSTIBLE CONCEALED FIRE BLOCKING AND DRAFT STOPPING SHALL BE INSTALLED IN COMBUSTIBLE CONCEALED LOCATIONS, BOTH VERTICAL AND HORIZONTAL, PER 2015 IBC-NJ SECTION 718.
AutoCAD SHX Text
3
AutoCAD SHX Text
1 HOUR RATED UFC FIRE BARRIER
AutoCAD SHX Text
4" CMU W/ FURRING
AutoCAD SHX Text
2
AutoCAD SHX Text
NON-RATED METAL STUD WALL
AutoCAD SHX Text
3-5/8" METAL STUD
AutoCAD SHX Text
MTL STUDS (16 GA.) @ 16" O.C. SEE TYPES BELOW FOR SIZE
AutoCAD SHX Text
FLEXIBLE SEALANT
AutoCAD SHX Text
EXISTING FLOOR/CEILING ABOVE
AutoCAD SHX Text
22GA DEEP LEG SLOTTED DEFLECTION
AutoCAD SHX Text
CONTINUOUS CHANNEL RUNNER
AutoCAD SHX Text
MTL STUD TRACK FASTENED TO FLOOR 24" O.C. MAX & 2" FROM END
AutoCAD SHX Text
FLEXIBLE SEALANT
AutoCAD SHX Text
(1) LAYERS 5/8" CEMENT BOARD
AutoCAD SHX Text
FLOOR FINISH, REFER TO FINISH PLANS
AutoCAD SHX Text
1A
AutoCAD SHX Text
1 HOUR UFC FIRE BARRIER
AutoCAD SHX Text
4" CMU
AutoCAD SHX Text
SOLID FILLED CMU, SEE SIZES BELOW
AutoCAD SHX Text
FLEXIBLE SEALANT
AutoCAD SHX Text
EXISTING FLOOR/CEILING ABOVE
AutoCAD SHX Text
FLOOR FINISH, REFER TO FINISH PLANS
AutoCAD SHX Text
1B
AutoCAD SHX Text
1 HOUR UFC FIRE BARRIER
AutoCAD SHX Text
6" CMU W/ FULL HEIGHT WATER PROOFING
AutoCAD SHX Text
MTL STUDS @ 16" O.C. SEE TYPES BELOW FOR SIZE
AutoCAD SHX Text
FLEXIBLE SEALANT
AutoCAD SHX Text
CONTINUOUS 22GA CHANNEL RUNNER
AutoCAD SHX Text
22GA MTL STUD TRACK FASTENED TO FLOOR 24" O.C. MAX & 2" FROM END
AutoCAD SHX Text
FLEXIBLE SEALANT
AutoCAD SHX Text
(1) LAYERS 5/8" CEMENT BOARD
AutoCAD SHX Text
TILE SYSTEM -TILE ADHESIVE -TILE PER FINISH PLAN
AutoCAD SHX Text
FLOOR FINISH, REFER TO FINISH PLANS
AutoCAD SHX Text
EXISTING FLOOR/CEILING ABOVE
AutoCAD SHX Text
SOLID FILLED CMU, SEE SIZES BELOW
AutoCAD SHX Text
TILE SYSTEM @ SHOWER -WATER PROOFING MEMBRANE -BONDING PRIMER -TILE ADHESIVE -TILE PER FINISH PLAN
AutoCAD SHX Text
TILE SYSTEM -TILE ADHESIVE -TILE PER FINISH PLAN
AutoCAD SHX Text
WATER PROOFING MEMBRANE AND AND BONDING PRIMER 4" UP WALL
AutoCAD SHX Text
WATER PROOFING MEMBRANE AND AND BONDING PRIMER 4" UP WALL
AutoCAD SHX Text
WATER PROOFING MEMBRANE AND AND BONDING PRIMER 4" UP WALL (FULL HEIGHT AT TYPE 1B)
AutoCAD SHX Text
1C
AutoCAD SHX Text
30 MINUTE UFC FIRE BARRIER
AutoCAD SHX Text
OMIT WATER PROOFING
AutoCAD SHX Text
A
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
J20 BASEMENT DEMOLITION PLAN J10 TYPICAL SECOND AND THIRD FLOOR DEMOLITION PLANJ17 FIRST FLOOR DEMOLITION PLAN J5 ROOF DEMOLITION PLAN
A10 DEMOLITION KEY NOTES A5 KEY PLANA15 GENERAL DEMOLITITON NOTES
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
EXISTING WALKWAY PAD TO REMAIN TYP.
AutoCAD SHX Text
EXISTING ROOF DRAIN TO REMAIN TPY.
AutoCAD SHX Text
EXISTING EXAUST FAN TO REMAIN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
COMMON AREA
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
LIVING
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
LIVING ROOM
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
STUDY
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
DN
AutoCAD SHX Text
H100
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
7
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
12
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
18
AutoCAD SHX Text
18
AutoCAD SHX Text
9
AutoCAD SHX Text
1
AutoCAD SHX Text
18
AutoCAD SHX Text
8
AutoCAD SHX Text
1
AutoCAD SHX Text
15
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
16
AutoCAD SHX Text
1
AutoCAD SHX Text
13
AutoCAD SHX Text
5
AutoCAD SHX Text
9
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
FE
AutoCAD SHX Text
119C
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
119A
AutoCAD SHX Text
LIVING RM.
AutoCAD SHX Text
119B
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
119D
AutoCAD SHX Text
BATH
AutoCAD SHX Text
6
AutoCAD SHX Text
14
AutoCAD SHX Text
ASSUME 180 S.F.
AutoCAD SHX Text
14
AutoCAD SHX Text
ASSUME 180 S.F.
AutoCAD SHX Text
22
AutoCAD SHX Text
21
AutoCAD SHX Text
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATINOS FOR MORE INFORMATION
AutoCAD SHX Text
8
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
18
AutoCAD SHX Text
2
AutoCAD SHX Text
7
AutoCAD SHX Text
3
AutoCAD SHX Text
10
AutoCAD SHX Text
12
AutoCAD SHX Text
9
AutoCAD SHX Text
11
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
13
AutoCAD SHX Text
5
AutoCAD SHX Text
9
AutoCAD SHX Text
9
AutoCAD SHX Text
6
AutoCAD SHX Text
5
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
Hx00
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
x20
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
x19/x20
AutoCAD SHX Text
BATH
AutoCAD SHX Text
x19
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
6
AutoCAD SHX Text
17
AutoCAD SHX Text
17
AutoCAD SHX Text
LINE OF WALLS (ABOVE)
AutoCAD SHX Text
A
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
5/03/2019
AutoCAD SHX Text
LF
AutoCAD SHX Text
TR, TDLR
AutoCAD SHX Text
A
AutoCAD SHX Text
5/03/19
AutoCAD SHX Text
ISSUED FOR BID / CONSTRUCTION
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
1
AutoCAD SHX Text
REMOVE EXISTING PLUMBING FIXTURE, REFER TO PLUMBING DRAWINGS REMOVE EXISTING LIGHT FIXTURE, REFER TO ELECTRICAL DRAWINGS DEMOLISH EXISTING FLOOR TILE, SETTING BED, AND BASE TILE, PREPARE SURFACE EXISTING CONCRETE SURFACE FOR NEW TILE FINISH DEMOLISH EXISTING WALL TILE, PREPARE SURFACE FOR NEW FINISH DEMOLISH EXISTING MARBLE SADDLE DEMOLISH EXISTING CERAMIC WALL TILE, PREPARE SURFACE FOR NEW TILE FINISH DEMOLISH EXISTING STONE SHELF DEMOLISH EXISTING MIRROR DEMOLISH EXISTING TOWEL BAR/HOOK DEMOLISH EXISTING SHOWER CURTAIN AND ROD DEMOLISH EXISTING SOAP DISH DEMOLISH EXISTING SHOWER FAN DEMOLISH EXISTING TOILET PAPER HOLDER DEMOLISH EXISTING CARPET, PREP FOR NEW FINISH DEMOLISH EXISTING CASEWORK DEMOLISH EXISTING ELECTRIC RANGE. REFER TO ELECTRIC DRAWINGS DEMOLISH EXISTING SLAB ON GRADE AS REQUIRED TO REPLACE EXISTING PIPING. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION DEMOLISH EXISTING MASONRY WALL AS REQUIRED TO ACCESS PLUMBING RISER, REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION DEMOLISH EXISTING PLUMBING VENT REFER TO PLUMBING DRAWINGS SALVAGE AND REMOVE EXISTING BIRD SCREEN ENCLOSURE. REINSTALL AT SAME LOCATION. REFER TO MEP DRAWINGS FOR MORE INFORMATION DEMOLISH EXISTING DOOR AND FRAME ASSEMBLY DEMOLISH EXISTING PARTITION. PATCH AND PAINT EXISTING WALL AND CEILING TO MATCH ADJACENT
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
21
AutoCAD SHX Text
22
AutoCAD SHX Text
GENERAL DEMOLITION NOTES: UNLESS OTHERWISE NOTED, GENERAL DEMOLITION NOTES REFER TO ALL TYPICAL CONDITIONS THROUGHOUT. 1. ALL DIMENSIONS PROVIDED FOR LOCATION AND EXTENT OF DEMOLITION ARE ALL DIMENSIONS PROVIDED FOR LOCATION AND EXTENT OF DEMOLITION ARE DIAGRAMMATIC OF SCOPE. EXACT DIMENSIONS ARE TO BE VERIFIED IN FIELD AND COORDINATED WITH DIMENSIONAL LAYOUTS OF CONSTRUCTION PLANS. 2. PROTECT EXISTING MATERIALS, DETAILS AND FIXTURES WHICH ARE NOT TO BE PROTECT EXISTING MATERIALS, DETAILS AND FIXTURES WHICH ARE NOT TO BE DEMOLISHED. 3. MARK LOCATION OF ALL UTILITIES TO REMAIN PRIOR TO DEMOLITION. MARK LOCATION OF ALL UTILITIES TO REMAIN PRIOR TO DEMOLITION. 4. NOTIFY ARCHITECT/ OWNER PRIOR TO START OF DEMOLITION WORK. NOTIFY ARCHITECT/ OWNER PRIOR TO START OF DEMOLITION WORK. 5. CEASE OPERATIONS IMMEDIATELY IF STRUCTURE APPEARS IN DANGER. NOTIFY ARCHITECT/ CEASE OPERATIONS IMMEDIATELY IF STRUCTURE APPEARS IN DANGER. NOTIFY ARCHITECT/ OWNER IMMEDIATELY. DO NOT RESUME OPERATION UNTIL DIRECTED. 6. DISCONNECT, CAP AND IDENTIFY DESIGNATED UTILITIES WITHIN DEMOLITION AREAS. DISCONNECT, CAP AND IDENTIFY DESIGNATED UTILITIES WITHIN DEMOLITION AREAS. 7. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER. PROTECT EXISTING SUPPORTING DEMOLISH IN AN ORDERLY AND CAREFUL MANNER. PROTECT EXISTING SUPPORTING STRUCTURAL MEMBERS. 8. REMOVE ALL DEMOLISHED MATERIAL FROM SITE AND LEGALLY DISPOSE. REMOVE ALL DEMOLISHED MATERIAL FROM SITE AND LEGALLY DISPOSE. 9. ITEMS SHOWN TO BE DEMOLISHED ON PLAN AND ELEVATIONS FOR REFERENCE ONLY. ITEMS SHOWN TO BE DEMOLISHED ON PLAN AND ELEVATIONS FOR REFERENCE ONLY. CONTRACTOR MUST INSPECT THE SITE AND COMPLETELY FAMILIARIZE HIM/ HERSELF WITH THE ITEMS TO BE REMOVED. QUESTIONS ABOUT ITEMS TO BE REMOVED OR TO REMAIN MUST BE GIVEN TO THE ARCHITECT IN WRITING. 10. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCY OR DEVIATION BETWEEN DRAWINGS NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCY OR DEVIATION BETWEEN DRAWINGS AND ANY FIELD VERIFIED CONDITIONS PRIOR TO COMMENCING WORK. 11. CONTRACTOR TO SECURE FACILITY, HIS TOOLS, EQUIPMENT, DUMPSTER AND MATERIALS CONTRACTOR TO SECURE FACILITY, HIS TOOLS, EQUIPMENT, DUMPSTER AND MATERIALS AGAINST VANDALISM, THEFT AND PREVENT UNAUTHORIZED ACCESS BY PUBLIC. 12. CONTRACTOR TO PERFORM DEMOLITION, CONSTRUCTION AND ALL OTHER WORK IN A CONTRACTOR TO PERFORM DEMOLITION, CONSTRUCTION AND ALL OTHER WORK IN A MANNER CAUSING AS LITTLE DISRUPTION TO THE OWNERS OPERATIONS AS POSSIBLE. 13. CONTRACTOR TO PROVIDE PROTECTION OF ALL EXISTING CONSTRUCTION AND FINISHES AS CONTRACTOR TO PROVIDE PROTECTION OF ALL EXISTING CONSTRUCTION AND FINISHES AS REQUIRED. ANY DAMAGE TO EXISTING CONSTRUCTION/FINISHES CAUSED DURING NEW WORK SHALL BE REPAIRED BY CONTRACTOR TO MATCH EXISTING AT NO ADDITIONAL COST TO THE OWNER.
J10 TYPICAL SECOND AND THIRD FLOOR PLAN J5 ROOF PLAN
A10 KEY NOTES A5 KEY PLAN
E10 BATHROOM ACCESSORIES SCHEDULE
A15 TYPICAL SECOND AND THIRD FLOOR REFLECTED CEILING PLAN
J15 FIRST FLOOR PLAN
E5 LIGHT FIXTURE SCHEDULE
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
COMMON AREA
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
LIVING
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BATH
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
LIVING ROOM
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
STUDY
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
DN
AutoCAD SHX Text
H100
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
FE
AutoCAD SHX Text
119C
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
119A
AutoCAD SHX Text
LIVING RM.
AutoCAD SHX Text
119B
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
119D
AutoCAD SHX Text
BATH
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
1A
AutoCAD SHX Text
1B
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
A-200
AutoCAD SHX Text
N20
AutoCAD SHX Text
N12
AutoCAD SHX Text
N8
AutoCAD SHX Text
N16
AutoCAD SHX Text
A-200
AutoCAD SHX Text
N4
AutoCAD SHX Text
A-200
AutoCAD SHX Text
J20
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
6
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
13
AutoCAD SHX Text
A-200
AutoCAD SHX Text
J8
AutoCAD SHX Text
I
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1B
AutoCAD SHX Text
16
AutoCAD SHX Text
16
AutoCAD SHX Text
K
AutoCAD SHX Text
J
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATIONS FOR MORE INFORMATION
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
Hx00
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
x20
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
x19/x20
AutoCAD SHX Text
BATH
AutoCAD SHX Text
x19
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
D
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
F
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
1A
AutoCAD SHX Text
1B
AutoCAD SHX Text
2
AutoCAD SHX Text
002
AutoCAD SHX Text
002
AutoCAD SHX Text
3
AutoCAD SHX Text
A-200
AutoCAD SHX Text
N20
AutoCAD SHX Text
J12
AutoCAD SHX Text
N8
AutoCAD SHX Text
J16
AutoCAD SHX Text
A-200
AutoCAD SHX Text
N4
AutoCAD SHX Text
A-200
AutoCAD SHX Text
J20
AutoCAD SHX Text
2
AutoCAD SHX Text
13
AutoCAD SHX Text
16
AutoCAD SHX Text
16
AutoCAD SHX Text
C
AutoCAD SHX Text
K
AutoCAD SHX Text
J
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
LINE OF WALLS (ABOVE)
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
EXISTING WALKWAY PAD TO REMAIN TYP.
AutoCAD SHX Text
EXISTING ROOF DRAIN TO REMAIN TPY.
AutoCAD SHX Text
EXISTING EXAUST FAN TO REMAIN
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
NEW VENT PIPE PENETRATION
AutoCAD SHX Text
H100
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
119C
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
119A
AutoCAD SHX Text
LIVING RM.
AutoCAD SHX Text
119B
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
119D
AutoCAD SHX Text
BATH
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATIONS FOR MORE INFORMATION
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
Hx00
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
x20
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
x19/x20
AutoCAD SHX Text
BATH
AutoCAD SHX Text
x19
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
002
AutoCAD SHX Text
002
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
10
AutoCAD SHX Text
D
AutoCAD SHX Text
A
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
5/03/2019
AutoCAD SHX Text
LF
AutoCAD SHX Text
TR, TDLR
AutoCAD SHX Text
A
AutoCAD SHX Text
5/03/19
AutoCAD SHX Text
ISSUED FOR BID / CONSTRUCTION
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
PIPE CHASE
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
PROVIDE NEW 4" THICK CONCRETE SLAB ON GRADE, REFER TO DETAIL A4, A8, AND A16/A-700. NEW SOLID SURFACE COUNTER TOP AND BACK SPLASH REFER TO FINISH PLANS AND MILLWORK DETAILS NEW BASE CABINETS REFER TO FINISH PLANS AND MILLWORK DETAILS NEW WALL CABINETS REFER TO FINISH PLANS AND MILLWORK DETAILS NEW RANGE, N.I.C. (BY OWNER) EXISTING HYDRONIC PIPING TO REMAIN, PAINT PER FINISH PLAN EXISTING FIRE EXTINGUISHER TO REMAIN NEW EXHAUST AIR LOUVER, REFER TO MECHANICAL DRAWINGS NEW PLUMBING VENT, REFER TO PLUMBING DRAWINGS NEW PTD. GYPSUM BOARD SOFFIT, REFER TO DETAIL J8/A-700. EXISTING SOFFIT TO REMAIN, PATCH AND REPAIR AS REQUIRED. PAINT COLOR PER FINISH PLANS. NOT USED. NEW 12"X12" ACCESS PANEL W/ SECURITY LOCK. PAINT TO MATCH PROPOSED TILE, REFER TO FINISH PLAN. LIGHT FIXTURE, REFER TO SCHEDULE SURFACE MOUNTED HEATING UNIT, REFER TO MECHANICAL DRAWINGS. PAINT PER FINISH PLANS. PAINT DOOR AND FRAME PER FINISH PLAN. ACCENT WALL TILE - REFER TO FINISH SCHEDULE FOR ADDITIONAL DETAILS. MOSAIC WALL TILE - REFER TO FINISH SCHEDULE FOR ADDITIONAL DETAILS.
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
A
AutoCAD SHX Text
NEW WALL MOUNTED WATER CLOSET, REFER TO PLUMBING DRAWINGS NEW UNDER MOUNT LAVATORY, REFER TO PLUMBING DRAWINGS NEW 30"x30" LOW PROFILE SHOWER BASE, REFER TO PLUMBING DRAWINGS NEW RECESSED MEDICINE CABINET, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-398 SIZE: 15"x27" MATERIAL: SATIN FINISHED STAINLESS STEEL NEW TOILET TISSUE DISPENSER, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-2716 MATERIAL: NYLON NEW SURFACE MOUNTED TOWEL BAR, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-6737 MATERIAL: SATIN FINISHED STAINLESS STEEL LENGTH: 18" NEW SURFACE MOUNTED DOUBLE ROBE HOOK, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-6727 MATERIAL: SATIN FINISHED STAINLESS STEEL NEW SHOWER HEAD, REFER TO PLUMBING DRAWINGS NEW KITCHEN SINK, REFER TO PLUMBING DRAWINGS NEW HEAVY DUTY SHOWER ROD MANUFACTURER: BOBRICK MODEL NUMBER: B-6107X30 MATERIAL: SATIN STAINLESS STEEL NEW 8" SHOWER CORNER SHELF MANUFACTURER: QUESTECH MODEL NUMBER: SBA154-024 MATERIAL: BRUSHED NICKEL COLOR NUMBER: 024 SIZE: 8" RETROFIT CORNER SHELF
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
I
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
LIGHT FIXTURE "A": SURFACE MOUNTED VANITY FIXTURE MANUF. BY: MODEL #: LAMP TYPE: LED WATTS: TYP. VOLTS: TYP.
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
LIGHT FIXTURE "B": SURFACE MOUNTED KITCHEN FIXTURE MANUF. BY: MODEL #: LAMP TYPE: LED WATTS: TYP. VOLTS: TYP.
AutoCAD SHX Text
LIGHT FIXTURE "C": UNDER CABINET LIGHTING FIXTURE MANUF. BY: MODEL #: LAMP TYPE: LED WATTS: TYP. VOLTS: TYP.
AutoCAD SHX Text
C
AutoCAD SHX Text
LIGHT FIXTURE "C": 4" DIAMETER RECESSED DOWNLIGHT MANUF. BY: MODEL #: LAMP TYPE: LED WATTS: TYP. VOLTS: TYP.
AutoCAD SHX Text
D
AutoCAD SHX Text
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATIONS FOR MORE INFORMATION
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATINOS FOR MORE INFORMATION
AutoCAD SHX Text
K
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
A
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
5/03/2019
AutoCAD SHX Text
LF
AutoCAD SHX Text
TR, TDLR
AutoCAD SHX Text
A
AutoCAD SHX Text
5/03/19
AutoCAD SHX Text
ISSUED FOR BID / CONSTRUCTION
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
PROVIDE NEW 4" THICK CONCRETE SLAB ON GRADE, REFER TO DETAIL A4, A8, AND A16/A-700. NEW SOLID SURFACE COUNTER TOP AND BACK SPLASH REFER TO FINISH PLANS AND MILLWORK DETAILS NEW BASE CABINETS REFER TO FINISH PLANS AND MILLWORK DETAILS NEW WALL CABINETS REFER TO FINISH PLANS AND MILLWORK DETAILS NEW RANGE, N.I.C. (BY OWNER) EXISTING HYDRONIC PIPING TO REMAIN, PAINT PER FINISH PLAN EXISTING FIRE EXTINGUISHER TO REMAIN NEW EXHAUST AIR LOUVER, REFER TO MECHANICAL DRAWINGS NEW PLUMBING VENT, REFER TO PLUMBING DRAWINGS NEW PTD. GYPSUM BOARD SOFFIT, REFER TO DETAIL J8/A-700. EXISTING SOFFIT TO REMAIN, PATCH AND REPAIR AS REQUIRED. PAINT COLOR PER FINISH PLANS. NOT USED. NEW 12"X12" ACCESS PANEL W/ SECURITY LOCK. PAINT TO MATCH PROPOSED TILE, REFER TO FINISH PLAN. LIGHT FIXTURE, REFER TO SCHEDULE SURFACE MOUNTED HEATING UNIT, REFER TO MECHANICAL DRAWINGS. PAINT PER FINISH PLANS. PAINT DOOR AND FRAME PER FINISH PLAN. ACCENT WALL TILE - REFER TO FINISH SCHEDULE FOR ADDITIONAL DETAILS. MOSAIC WALL TILE - REFER TO FINISH SCHEDULE FOR ADDITIONAL DETAILS.
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
A
AutoCAD SHX Text
NEW WALL MOUNTED WATER CLOSET, REFER TO PLUMBING DRAWINGS NEW UNDER MOUNT LAVATORY, REFER TO PLUMBING DRAWINGS NEW 30"x30" LOW PROFILE SHOWER BASE, REFER TO PLUMBING DRAWINGS NEW RECESSED MEDICINE CABINET, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-398 SIZE: 15"x27" MATERIAL: SATIN FINISHED STAINLESS STEEL NEW TOILET TISSUE DISPENSER, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-2716 MATERIAL: NYLON NEW SURFACE MOUNTED TOWEL BAR, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-6737 MATERIAL: SATIN FINISHED STAINLESS STEEL LENGTH: 18" NEW SURFACE MOUNTED DOUBLE ROBE HOOK, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-6727 MATERIAL: SATIN FINISHED STAINLESS STEEL NEW SHOWER HEAD, REFER TO PLUMBING DRAWINGS NEW KITCHEN SINK, REFER TO PLUMBING DRAWINGS NEW HEAVY DUTY SHOWER ROD MANUFACTURER: BOBRICK MODEL NUMBER: B-6107X30 MATERIAL: SATIN STAINLESS STEEL NEW 8" SHOWER CORNER SHELF MANUFACTURER: QUESTECH MODEL NUMBER: SBA154-024 MATERIAL: BRUSHED NICKEL COLOR NUMBER: 024 SIZE: 8" RETROFIT CORNER SHELF
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATIONS FOR MORE INFORMATION
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
Hx00
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
x20
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
x19/x20
AutoCAD SHX Text
BATH
AutoCAD SHX Text
x19
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
D
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
F
AutoCAD SHX Text
TYP. OF (2)
AutoCAD SHX Text
1A
AutoCAD SHX Text
1B
AutoCAD SHX Text
2
AutoCAD SHX Text
002
AutoCAD SHX Text
002
AutoCAD SHX Text
3
AutoCAD SHX Text
A-200
AutoCAD SHX Text
N20
AutoCAD SHX Text
J12
AutoCAD SHX Text
N8
AutoCAD SHX Text
J16
AutoCAD SHX Text
A-200
AutoCAD SHX Text
N4
AutoCAD SHX Text
A-200
AutoCAD SHX Text
J20
AutoCAD SHX Text
2
AutoCAD SHX Text
13
AutoCAD SHX Text
16
AutoCAD SHX Text
16
AutoCAD SHX Text
C
AutoCAD SHX Text
K
AutoCAD SHX Text
J
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
LINE OF WALLS (ABOVE)
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
EXISTING WALKWAY PAD TO REMAIN TYP.
AutoCAD SHX Text
EXISTING ROOF DRAIN TO REMAIN TPY.
AutoCAD SHX Text
EXISTING EXAUST FAN TO REMAIN
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
NEW VENT PIPE PENETRATION
AutoCAD SHX Text
H100
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
119C
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
119A
AutoCAD SHX Text
LIVING RM.
AutoCAD SHX Text
119B
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
119D
AutoCAD SHX Text
BATH
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATIONS FOR MORE INFORMATION
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
Hx00
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
x20
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
x19/x20
AutoCAD SHX Text
BATH
AutoCAD SHX Text
x19
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
002
AutoCAD SHX Text
002
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
10
AutoCAD SHX Text
D
AutoCAD SHX Text
A
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
5/03/2019
AutoCAD SHX Text
LF
AutoCAD SHX Text
TR, TDLR
AutoCAD SHX Text
A
AutoCAD SHX Text
5/03/19
AutoCAD SHX Text
ISSUED FOR BID / CONSTRUCTION
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
PIPE CHASE
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
PROVIDE NEW 4" THICK CONCRETE SLAB ON GRADE, REFER TO DETAIL A4, A8, AND A16/A-700. NEW SOLID SURFACE COUNTER TOP AND BACK SPLASH REFER TO FINISH PLANS AND MILLWORK DETAILS NEW BASE CABINETS REFER TO FINISH PLANS AND MILLWORK DETAILS NEW WALL CABINETS REFER TO FINISH PLANS AND MILLWORK DETAILS NEW RANGE, N.I.C. (BY OWNER) EXISTING HYDRONIC PIPING TO REMAIN, PAINT PER FINISH PLAN EXISTING FIRE EXTINGUISHER TO REMAIN NEW EXHAUST AIR LOUVER, REFER TO MECHANICAL DRAWINGS NEW PLUMBING VENT, REFER TO PLUMBING DRAWINGS NEW PTD. GYPSUM BOARD SOFFIT, REFER TO DETAIL J8/A-700. EXISTING SOFFIT TO REMAIN, PATCH AND REPAIR AS REQUIRED. PAINT COLOR PER FINISH PLANS. NOT USED. NEW 12"X12" ACCESS PANEL W/ SECURITY LOCK. PAINT TO MATCH PROPOSED TILE, REFER TO FINISH PLAN. LIGHT FIXTURE, REFER TO SCHEDULE SURFACE MOUNTED HEATING UNIT, REFER TO MECHANICAL DRAWINGS. PAINT PER FINISH PLANS. PAINT DOOR AND FRAME PER FINISH PLAN. ACCENT WALL TILE - REFER TO FINISH SCHEDULE FOR ADDITIONAL DETAILS. MOSAIC WALL TILE - REFER TO FINISH SCHEDULE FOR ADDITIONAL DETAILS.
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
A
AutoCAD SHX Text
NEW WALL MOUNTED WATER CLOSET, REFER TO PLUMBING DRAWINGS NEW UNDER MOUNT LAVATORY, REFER TO PLUMBING DRAWINGS NEW 30"x30" LOW PROFILE SHOWER BASE, REFER TO PLUMBING DRAWINGS NEW RECESSED MEDICINE CABINET, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-398 SIZE: 15"x27" MATERIAL: SATIN FINISHED STAINLESS STEEL NEW TOILET TISSUE DISPENSER, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-2716 MATERIAL: NYLON NEW SURFACE MOUNTED TOWEL BAR, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-6737 MATERIAL: SATIN FINISHED STAINLESS STEEL LENGTH: 18" NEW SURFACE MOUNTED DOUBLE ROBE HOOK, BASIS OF DESIGN: MANUFACTURER: BOBRICK MODEL NUMBER: B-6727 MATERIAL: SATIN FINISHED STAINLESS STEEL NEW SHOWER HEAD, REFER TO PLUMBING DRAWINGS NEW KITCHEN SINK, REFER TO PLUMBING DRAWINGS NEW HEAVY DUTY SHOWER ROD MANUFACTURER: BOBRICK MODEL NUMBER: B-6107X30 MATERIAL: SATIN STAINLESS STEEL NEW 8" SHOWER CORNER SHELF MANUFACTURER: QUESTECH MODEL NUMBER: SBA154-024 MATERIAL: BRUSHED NICKEL COLOR NUMBER: 024 SIZE: 8" RETROFIT CORNER SHELF
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
I
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
LIGHT FIXTURE "A": SURFACE MOUNTED VANITY FIXTURE MANUF. BY: MODEL #: LAMP TYPE: LED WATTS: TYP. VOLTS: TYP.
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
LIGHT FIXTURE "B": SURFACE MOUNTED KITCHEN FIXTURE MANUF. BY: MODEL #: LAMP TYPE: LED WATTS: TYP. VOLTS: TYP.
AutoCAD SHX Text
LIGHT FIXTURE "C": UNDER CABINET LIGHTING FIXTURE MANUF. BY: MODEL #: LAMP TYPE: LED WATTS: TYP. VOLTS: TYP.
AutoCAD SHX Text
C
AutoCAD SHX Text
LIGHT FIXTURE "C": 4" DIAMETER RECESSED DOWNLIGHT MANUF. BY: MODEL #: LAMP TYPE: LED WATTS: TYP. VOLTS: TYP.
AutoCAD SHX Text
D
AutoCAD SHX Text
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATIONS FOR MORE INFORMATION
SCHEDULE OF PLUMBING FIXTURES AND CONNECTIONSRDL
8" MIN.
TYPICAL INSULATED PIPE HANGER DETAILTYPICAL SERVICE STOP INSTALLATION DETAIL
1 " TOP SPUD, 1.6 GALLON FLUSH. ZURN Z5955SS-EL-AM-STS SEAT.12" TOP SPUD, 1.6 GALLON FLUSH. ZURN Z5955SS-EL-AM-STS SEAT.
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
UNDER MOUNT
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
15" x 12"
AutoCAD SHX Text
INTEGRAL WITH FAUCET
AutoCAD SHX Text
4"
AutoCAD SHX Text
WITH FAUCET
AutoCAD SHX Text
17 GAUGE 1 " X 1 "14" X 1 "12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
---
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
P-TRAP SHALL BE ADJUSTABLE CAST BRASS WITH CLEANOUT. PROVIDE ZURN Z8946-3-NT PROTECTIVE COVERINGS FOR ALL TAILPIECES, TRAP, SUPPLIES. PROVIDE WITH WODER 10K-FRM GEN II IN-LINE FILTER, OR EQUIVALENT.
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%US
AutoCAD SHX Text
SINK
AutoCAD SHX Text
ELKAY
AutoCAD SHX Text
LR1722
AutoCAD SHX Text
SINGLE BOWL DROP IN
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
SELF-RIMMING
AutoCAD SHX Text
INTEGRAL WITH FAUCET
AutoCAD SHX Text
8"
AutoCAD SHX Text
LK99
AutoCAD SHX Text
17 GAUGE 1 " X 1 "12" X 1 "12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
---
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
P-TRAP SHALL BE ADJUSTABLE CAST BRASS WITH CLEANOUT. PROVIDE WITH WODER 10K-FRM GEN II IN-LINE FILTER, OR EQUIVALENT.
AutoCAD SHX Text
%%US
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
FIAT
AutoCAD SHX Text
ZURN MODEL Z7301-SS-MT
AutoCAD SHX Text
SINGLE LEVER
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
---
AutoCAD SHX Text
2"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
PROVIDE WITH QUICK DRAIN CONNECTOR QDC4, WITH STAINLESS STEEL STRAINER. PROVIDE 12"x12" STAINLESS STEEL LOCKABLE ACCESS PANEL IN WALL BEHIND SHOWER VALVE.
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
KOHLER
AutoCAD SHX Text
K-2209-0
AutoCAD SHX Text
ZURN
AutoCAD SHX Text
Z5615-BWL
AutoCAD SHX Text
ZURN MODEL Z6011AV-WS1
AutoCAD SHX Text
ZURN Z8804-XL -LK-Q-PC
AutoCAD SHX Text
ZURN Z8804-XL -LK-Q-PC
AutoCAD SHX Text
ZURN MODEL Z81000-XL-P
AutoCAD SHX Text
ZURN MODEL Z871G3-XL-HCT-18F
AutoCAD SHX Text
---
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
LEVER
AutoCAD SHX Text
TWO LEVER
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
30MFT
AutoCAD SHX Text
30" X 30"
AutoCAD SHX Text
SHOWER PAN
AutoCAD SHX Text
TERRAZZO (501)
AutoCAD SHX Text
VAPOR BARRIER
AutoCAD SHX Text
HOT OR COLD WATER PIPE
AutoCAD SHX Text
PROVIDE VAPOR BARRIER OVER SADDLE BLOCKS AND INSULATION
AutoCAD SHX Text
LOCKING NUT
AutoCAD SHX Text
ADJUSTING NUT
AutoCAD SHX Text
CLEVIS HANGER
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
HARD WOOD SADDLE
AutoCAD SHX Text
PROVIDE INSULATION BETWEEN SADDLE BLOCKS
AutoCAD SHX Text
NOTES: 1. PROVIDE PIPE COVERING SHIELD AT EACH CLEVIS HANGER. INSTALL PROVIDE PIPE COVERING SHIELD AT EACH CLEVIS HANGER. INSTALL SHIELD BETWEEN VAPOR BARRIER AND CLEVIS HANGER. 2. THIS DETAIL IS TYPICAL FOR ALL OTHER HANGERS AND SUPPORTS.THIS DETAIL IS TYPICAL FOR ALL OTHER HANGERS AND SUPPORTS.
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
PIPING
AutoCAD SHX Text
HARD WOOD SADDLE
AutoCAD SHX Text
CLEVIS HANGER
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
PIPE COVERING SHIELD
AutoCAD SHX Text
VAPOR BARRIER
AutoCAD SHX Text
3/8" O.Dx12" LONG FLEXIBLE SUPPLY RISER
AutoCAD SHX Text
INSULATION SHALL BE MITERED AND TAPED AT END JOINT
AutoCAD SHX Text
1" MAX.
AutoCAD SHX Text
ZURN MODEL Z8808LKQ-PC SERVICE STOP
AutoCAD SHX Text
LOOSE KEY STOP
AutoCAD SHX Text
CHROME PLATED ESCUTCHEON
AutoCAD SHX Text
TEE HANDLE SHALL BE GIVEN TO OWNER UPON COMPLETION OF PROJECT
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
INSULATION SHALL BE MITERED AND TAPED AT ALL CHANGES IN DIRECTION
AutoCAD SHX Text
1/2" COPPER
AutoCAD SHX Text
1/2" COPPER SOLDER X 1/2" COPPER SOLDER
AutoCAD SHX Text
1/2" COPPER
AutoCAD SHX Text
PIPE POSITIONING UNIT
AutoCAD SHX Text
WATER CLOSET - WALL HUNG FLUSH VALVE
AutoCAD SHX Text
LAVATORY - UNDERMOUNT
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXST
AutoCAD SHX Text
VTR
AutoCAD SHX Text
SH
AutoCAD SHX Text
L
AutoCAD SHX Text
WC
AutoCAD SHX Text
RISER UP
AutoCAD SHX Text
RISER DOWN
AutoCAD SHX Text
BRANCH CONNECTION OFF TOP
AutoCAD SHX Text
RISER OR DROP
AutoCAD SHX Text
FLOW-IN DIRECTION OF ARROW
AutoCAD SHX Text
SHUT-OFF VALVE
AutoCAD SHX Text
DOMESTIC HOT WATER
AutoCAD SHX Text
DOMESTIC COLD WATER
AutoCAD SHX Text
SANITARY VENT
AutoCAD SHX Text
SANITARY WASTE
AutoCAD SHX Text
CW
AutoCAD SHX Text
HW
AutoCAD SHX Text
WATER HAMMER ARRESTER ZURN Z-1700 SIZE A-(100), B-(200), C-(300), D-(400)
AutoCAD SHX Text
CONNECTION POINT- NEW TO EXISTING
AutoCAD SHX Text
END CAP
AutoCAD SHX Text
A
AutoCAD SHX Text
SINK - DROP-IN
AutoCAD SHX Text
S
AutoCAD SHX Text
A
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
A
AutoCAD SHX Text
5/03/19
AutoCAD SHX Text
ISSUED FOR BID / CONSTRUCTION
AutoCAD SHX Text
5/3/2019
AutoCAD SHX Text
RDL
AutoCAD SHX Text
RDL
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
SCALE: NONE
FIRST FLOOR PLUMBING PLANUNDER SLAB PLUMBING PLAN SECOND FLOOR PLUMBING PLAN THIRD FLOOR PLUMBING PLAN
KEYED NOTES:
GENERAL REMOVAL NOTES
DOMESTIC WATER RISER DIAGRAMWASTE AND VENT RISER DIAGRAM
1 " COLD WATER AND 12" COLD WATER AND 1" HOT WATER UP TO FIRST FLOOR.
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
7
AutoCAD SHX Text
2
AutoCAD SHX Text
6
AutoCAD SHX Text
8
AutoCAD SHX Text
3
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
BATH
AutoCAD SHX Text
19
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
11
AutoCAD SHX Text
10
AutoCAD SHX Text
9
AutoCAD SHX Text
3
AutoCAD SHX Text
12
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
CLO.
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
BATH
AutoCAD SHX Text
19
AutoCAD SHX Text
1. 2" VENT DOWN TO WATER CLOSET AND 2" VENT UP TO SECOND 2" VENT DOWN TO WATER CLOSET AND 2" VENT UP TO SECOND FLOOR. 2. 4" WASTE DOWN TO CRAWL SPACE AND 4" WASTE UP TO SECOND 4" WASTE DOWN TO CRAWL SPACE AND 4" WASTE UP TO SECOND FLOOR. 3. 2" WASTE RUN IN WALL BELOW AND 1 " VENT RUN IN WALL. 2" WASTE RUN IN WALL BELOW AND 1 " VENT RUN IN WALL. 12" VENT RUN IN WALL. 4. 3" WASTE DOWN TO CRAWL SPACE AND 3" WASTE UP TO SECOND 3" WASTE DOWN TO CRAWL SPACE AND 3" WASTE UP TO SECOND FLOOR. 5. 1 " VENT UP TO SECOND FLOOR. 1 " VENT UP TO SECOND FLOOR. 12" VENT UP TO SECOND FLOOR. 6. 2" VENT DOWN TO FIRST FLOOR AND 2" VENT UP TO THIRD FLOOR. 2" VENT DOWN TO FIRST FLOOR AND 2" VENT UP TO THIRD FLOOR. 7. 2" WASTE DOWN TO FIRST FLOOR AND 2" WASTE UP TO THIRD FLOOR. 2" WASTE DOWN TO FIRST FLOOR AND 2" WASTE UP TO THIRD FLOOR. 8. 1 " VENT DOWN TO FIRST FLOOR AND 1 " VENT UP TO THIRD FLOOR. 1 " VENT DOWN TO FIRST FLOOR AND 1 " VENT UP TO THIRD FLOOR. 12" VENT DOWN TO FIRST FLOOR AND 1 " VENT UP TO THIRD FLOOR. 12" VENT UP TO THIRD FLOOR. 9. 2" VENT DOWN TO SECOND FLOOR. 2" VENT DOWN TO SECOND FLOOR. 10. 4" WASTE DOWN TO SECOND FLOOR AND 4" VENT UP AND THROUGH 4" WASTE DOWN TO SECOND FLOOR AND 4" VENT UP AND THROUGH ROOF. 11. 2" WASTE DOWN TO SECOND FLOOR. 2" WASTE DOWN TO SECOND FLOOR. 12. 1 " VENT DOWN TO SECOND FLOOR AND 2" VENT UP. 3" VENT 1 " VENT DOWN TO SECOND FLOOR AND 2" VENT UP. 3" VENT 12" VENT DOWN TO SECOND FLOOR AND 2" VENT UP. 3" VENT THROUGH ROOF. 13. 1" HOT AND COLD WATER DOWN TO CRAWL SPACE. " HOT AND 1" HOT AND COLD WATER DOWN TO CRAWL SPACE. " HOT AND 34" HOT AND COLD WATER UP TO SECOND FLOOR. EXTEND AND CONNECT " HOT 12" HOT AND COLD WATER TO EACH LAVATORY AND SINK. 14. 1 " COLD WATER AND " HOT WATER UP TO SECOND FLOOR. 1 " 1 " COLD WATER AND " HOT WATER UP TO SECOND FLOOR. 1 " 12" COLD WATER AND " HOT WATER UP TO SECOND FLOOR. 1 " 34" HOT WATER UP TO SECOND FLOOR. 1 " 12" COLD WATER AND 1" HOT WATER DOWN TO CRAWL SPACE. EXTEND AND CONNECT 1 " COLD WATER TO WATER CLOSET AND " HOT AND 14" COLD WATER TO WATER CLOSET AND " HOT AND 12" HOT AND COLD WATER TO SHOWER VALVE THROUGH NEW STUD WALL. 15. " HOT AND COLD WATER DOWN TO FIRST FLOOR. EXTEND AND 34" HOT AND COLD WATER DOWN TO FIRST FLOOR. EXTEND AND EXTEND AND CONNECT " HOT AND COLD WATER TO EACH LAVATORY. " HOT AND 12" HOT AND COLD WATER TO EACH LAVATORY. " HOT AND 12" HOT AND COLD WATER UP TO THIRD FLOOR. 16. 1 " COLD WATER AND " HOT WATER DOWN TO FIRST FLOOR. 1 " COLD WATER AND " HOT WATER DOWN TO FIRST FLOOR. 12" COLD WATER AND " HOT WATER DOWN TO FIRST FLOOR. 34" HOT WATER DOWN TO FIRST FLOOR. EXTEND AND CONNECT 1 " COLD WATER TO WATER CLOSET AND " 14" COLD WATER TO WATER CLOSET AND " 12" HOT AND COLD WATER TO SHOWER VALVE THROUGH NEW STUD WALL. 1 " COLD WATER AND " HOT WATER UP TO THIRD FLOOR. 14" COLD WATER AND " HOT WATER UP TO THIRD FLOOR. 12" HOT WATER UP TO THIRD FLOOR. 17. " HOT AND COLD WATER UP FROM SECOND FLOOR. EXTEND AND 12" HOT AND COLD WATER UP FROM SECOND FLOOR. EXTEND AND CONNECT TO EACH LAVATORY. 18. 1 " COLD WATER AND " HOT WATER UP FROM SECOND FLOOR. 1 " COLD WATER AND " HOT WATER UP FROM SECOND FLOOR. 14" COLD WATER AND " HOT WATER UP FROM SECOND FLOOR. 12" HOT WATER UP FROM SECOND FLOOR. EXTEND AND CONNECT 1 " COLD WATER TO WATER CLOSET AND " 14" COLD WATER TO WATER CLOSET AND " 12" HOT AND COLD WATER TO SHOWER VALVE THROUGH NEW STUD WALL. 19. PROVIDE 1" INSULATION AND PVC JACKET FOR EXPOSED PIPE AND PROVIDE 1" INSULATION AND PVC JACKET FOR EXPOSED PIPE AND P-TRAP IN BATHROOM. SEAL WATER TIGHT. 20. IN FIRST FLOOR KITCHEN AND BATHROOM DEMO AND REPLACE FLOOR IN FIRST FLOOR KITCHEN AND BATHROOM DEMO AND REPLACE FLOOR TO LIMITS NECESSARY FOR REPLACEMENT OF PIPING. COORDINATE WITH ARCHITECTURAL DRAWINGS.
AutoCAD SHX Text
A.ALL EXISTING PLUMBING FIXTURES AND PIPING SERVING THESE ALL EXISTING PLUMBING FIXTURES AND PIPING SERVING THESE FIXTURES SHALL BE REMOVED COMPLETE. EXISTING PIPING IS ROUTED AND IS THE SAME SIZE AS THE NEW SHOWN.
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
A
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
A
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
A
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
34"
AutoCAD SHX Text
34"
AutoCAD SHX Text
1"
AutoCAD SHX Text
1"
AutoCAD SHX Text
34"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
12"
AutoCAD SHX Text
1"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
%%US
AutoCAD SHX Text
1"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
%%UWC
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%UL
AutoCAD SHX Text
%%U3"VTR
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
3"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
%%US
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
4" VENT THROUGH PARAPET WALL.
AutoCAD SHX Text
4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
2"
AutoCAD SHX Text
%%USH
AutoCAD SHX Text
1 " 12"
AutoCAD SHX Text
2"
AutoCAD SHX Text
A
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
A
AutoCAD SHX Text
5/03/19
AutoCAD SHX Text
ISSUED FOR BID / CONSTRUCTION
AutoCAD SHX Text
5/3/2019
AutoCAD SHX Text
RDL
AutoCAD SHX Text
RDL
shicks
Callout
ADD ALTERNATE #1 SEE SHEET G-001 AND SPECIFICATIONS FOR MORE INFORMATION
EXISTING 24X6 EXHAUST UP TO SECOND FLR TO BE REMOVED COMPLETE.
AutoCAD SHX Text
EXISTING 3.5X10 EXHAUST DUCT TO BE REMOVED COMPLETE
AutoCAD SHX Text
DN
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
R-1
AutoCAD SHX Text
24x6
AutoCAD SHX Text
4x10
AutoCAD SHX Text
CONTRACTOR TO INSTALL ISOLATION VALVE AND BALANCING VALVE AT RISER IN TRENCH.
AutoCAD SHX Text
R-1
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
24x6
AutoCAD SHX Text
4x10
AutoCAD SHX Text
CONTRACTOR TO INSTALL ISOLATION VALVE AND BALANCING VALVE AT RISER IN TRENCH.
AutoCAD SHX Text
CONTRACTOR TO REMOVE EXISTING HYDRONIC HEATER.
AutoCAD SHX Text
EXISTING EXHAUST FAN TO BE REMOVED COMPLETE.
AutoCAD SHX Text
EXISTING 24X6 EXHAUST UP FROM SECOND FLR TO ROOF TO BE REMOVED COMPLETE.
AutoCAD SHX Text
EXISTING 3.5X10 EXHAUST DUCT TO BE REMOVED COMPLETE
AutoCAD SHX Text
A
AutoCAD SHX Text
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
05/03/2019
AutoCAD SHX Text
SCHEDULE OF EXHAUST FANS
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
HP
AutoCAD SHX Text
FRPM
AutoCAD SHX Text
CFM
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
FAN MOUNTING
AutoCAD SHX Text
ELECTRICAL CHARACTERISTICS
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
GREENHECK
AutoCAD SHX Text
3
AutoCAD SHX Text
SP
AutoCAD SHX Text
A90-130
AutoCAD SHX Text
1/10
AutoCAD SHX Text
1040
AutoCAD SHX Text
125
AutoCAD SHX Text
0.45
AutoCAD SHX Text
SIDEWALL
AutoCAD SHX Text
115/1
AutoCAD SHX Text
ALL
AutoCAD SHX Text
NOTES: 1. FURNISH WITH BACKDRAFT DAMPER, GRILLE, DISCONNECT, AND MOTOR SPEED DIAL. 2. TERMINATE AT ROOF WITH DOWN-TURNED GOOSENECK. PROVIDE WITH BIRD SCREEN.
AutoCAD SHX Text
%%UFIRST FLOOR BATHROOM HVAC REMOVAL PLAN
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
%%UGENERAL NOTES:
AutoCAD SHX Text
A. THE REMOVAL DRAWINGS SHALL SERVE TO AID THE THE REMOVAL DRAWINGS SHALL SERVE TO AID THE CONTRACTOR IN THE EVALUATION OF THE EXTENT OF REMOVALS, BUT SHALL NOT BE HELD TO BE ALL INCLUSIVE. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE AREA TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. VERIFY SIZE, LOCATION, AND USAGE OF EXISTING UTILITIES PRIOR TO REMOVAL. FOR FURTHER INFORMATION WITH REGARD TO THE EXTENT OF REMOVALS, SEE THE ARCHITECTURAL DRAWINGS. C. OWNER SHALL BE GIVEN FIRST CHOICE ON ALL OWNER SHALL BE GIVEN FIRST CHOICE ON ALL EQUIPMENT BEING REMOVED THAT WILL NOT BE RELOCATED. CONTRACTOR SHALL REVIEW THE EXISTING EQUIPMENT WITH OWNER. EQUIPMENT BEING REMOVED OR RELOCATED SHALL BE REMOVED IN A MANNER THAT REUSE IS POSSIBLE AND STORED AS DIRECTED BY OWNER. ALL OTHER EQUIPMENT SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED & DISPOSED OF FROM THE SITE BY THE CONTRACTOR. D. DRAWING IS DIAGRAMMATIC, PROVIDE ADDITIONAL DRAWING IS DIAGRAMMATIC, PROVIDE ADDITIONAL OFFSETS, TRANSITIONS, ETC. AS REQUIRED TO AVOID INTERFERENCE'S ENCOUNTERED. RELOCATION OF EXISTING DUCT AND EQUIPMENT HANGERS REQUIRED FOR INSTALLATION WORK SHALL BE CONSIDERED PART OF THIS CONTRACT.
AutoCAD SHX Text
S.P.
AutoCAD SHX Text
SHT.
AutoCAD SHX Text
RM.
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
PRESS.
AutoCAD SHX Text
HTR.
AutoCAD SHX Text
PRESSURE
AutoCAD SHX Text
HEATER
AutoCAD SHX Text
EXG.
AutoCAD SHX Text
EXH.
AutoCAD SHX Text
EF
AutoCAD SHX Text
DN.
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXHAUST
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
%%UHVAC SYMBOLS AND
AutoCAD SHX Text
ASSOC.
AutoCAD SHX Text
CAP.
AutoCAD SHX Text
BTUH
AutoCAD SHX Text
A.F.F.
AutoCAD SHX Text
CAPACITY
AutoCAD SHX Text
ASSOCIATED
AutoCAD SHX Text
BTU/HR
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
NOTE: NOT ALL SYMBOLS MAY BE USED.
AutoCAD SHX Text
BHP
AutoCAD SHX Text
BRAKE HORSEPOWER
AutoCAD SHX Text
DIA.
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
ENT.
AutoCAD SHX Text
ENTERING
AutoCAD SHX Text
EXT.
AutoCAD SHX Text
EXTERNAL
AutoCAD SHX Text
PSI
AutoCAD SHX Text
POUNDS PER SQUARE INCH
AutoCAD SHX Text
%%UABBREVIATIONS LEGEND
AutoCAD SHX Text
%%UFIRST FLOOR BATHROOM HVAC PLAN
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
SCHEDULE OF HYDRONIC BASEBOARD HEATER
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
FLOW (GPM)
AutoCAD SHX Text
HEATING CAPACITY (BTU/LINEAR FOOT)
AutoCAD SHX Text
MINIMUM LENGTH (FT)
AutoCAD SHX Text
MOUNTING
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
R-1
AutoCAD SHX Text
CLASSIC
AutoCAD SHX Text
CLCU75
AutoCAD SHX Text
1.0
AutoCAD SHX Text
660
AutoCAD SHX Text
5
AutoCAD SHX Text
SURFACE
AutoCAD SHX Text
ALL
AutoCAD SHX Text
NOTES: 1. COLOR AS SELECTED BY ARCHITECT. 2. CONTRACTOR TO FIELD VERIFY LENGTH OF MOUNTING WALL. 3. CONTRACTOR TO MODIFY PIPING CONNECTIONS AS REQUIRED FOR INSTALLATION. 4. CONTRACTOR TO VERIFY WATER FLOW AFTER INSTALLATION.
AutoCAD SHX Text
%%UPHOTO 1:
AutoCAD SHX Text
HATCHED EXISTING EXHAUST DUCT IS TO BE REMOVED AND PATCHED. CONTRACTOR SHALL TERMINATE NEW EXHAUST DUCT AT PARAPET WITH DOWN-TURNING GOOSENECK.
AutoCAD SHX Text
TLP
AutoCAD SHX Text
JKL
AutoCAD SHX Text
%%USECOND/THIRD FLOOR BATHROOM HVAC REMOVAL PLAN
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
%%USECOND/THIRD FLOOR BATHROOM HVAC PLAN
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
1. CONTRACTOR TO RUN 24X6 E.A. DUCT FROM THE FIRST FLOOR UP THROUGH CONTRACTOR TO RUN 24X6 E.A. DUCT FROM THE FIRST FLOOR UP THROUGH SECOND/THIRD FLOOR TO ROOF PARAPET. REFER TO PHOTO 1. 2. RADIATOR COVER SHALL BE PAINTED BEFORE INSTALLATION. RADIATOR COVER SHALL BE PAINTED BEFORE INSTALLATION.
ROWAN UNIVERSITY 201 MULLICA HILL RD. GLASSBORO NJ, 08029
AutoCAD SHX Text
OWNER:
AutoCAD SHX Text
BCCCT CONSULTING 1138 E. CHESTNUT AVE SUITE 7A VINELAND, NJ 08360
AutoCAD SHX Text
MEP-FP:
AutoCAD SHX Text
SUBMISSIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING NO.:
AutoCAD SHX Text
CCH PROJECT NO:
AutoCAD SHX Text
2085
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
05/03/2019
AutoCAD SHX Text
KYL
AutoCAD SHX Text
SMH
AutoCAD SHX Text
%%UFIRST FLOOR ELECTRICAL REMOVAL PLAN
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
%%UELECTRICAL LEGEND
AutoCAD SHX Text
SURFACE MOUNTED LIGHTING FIXTURE AS SCHEDULED.
AutoCAD SHX Text
INDICATES SURFACE RACEWAY. MINIMUM SIZE RACEWAY SHALL BE LEGRAND WIREMOLD 400BAC OR EQUIVALENT. SIZE RACEWAY IN ACCORDANCE WITH NEC WIRE FILL REQUIREMENTS.
AutoCAD SHX Text
S
AutoCAD SHX Text
1. EXISTING LIGHTING FIXTURE TO BE DISCONNECTED AND REMOVED. EXISTING LIGHTING FIXTURE TO BE DISCONNECTED AND REMOVED. 2. CONNECT NEW 'TYPE A' LIGHTING FIXTURES AS INDICATED TO EXISTING CONNECT NEW 'TYPE A' LIGHTING FIXTURES AS INDICATED TO EXISTING LIGHTING CIRCUIT. 3. RECONNECT NEW EXHAUST FAN TO EXISTING CIRCUIT. RECONNECT UNIT RECONNECT NEW EXHAUST FAN TO EXISTING CIRCUIT. RECONNECT UNIT TO NEW SWITCH ON WALL. 4. PROVIDE BLANK OUTLET BOX WITH COVER PLATE. PROVIDE BLANK OUTLET BOX WITH COVER PLATE. 5. ROUTE CONDUITS FROM FIRST, SECOND, AND THIRD FLOOR DOWN ROUTE CONDUITS FROM FIRST, SECOND, AND THIRD FLOOR DOWN THROUGH SHAFT WALL INTO TUNNEL. 6. CONNECT NEW 'TYPE B' DOWNLIGHT FIXTURE TO EXISTING LIGHTING CONNECT NEW 'TYPE B' DOWNLIGHT FIXTURE TO EXISTING LIGHTING CIRCUIT. RECONNECT FIXTURE TO EXISTING LIGHTING SWITCH. 7. RECONNECT NEW UNDERCABINET LIGHTING TO EXISTING LIGHTING RECONNECT NEW UNDERCABINET LIGHTING TO EXISTING LIGHTING CIRCUIT. EXTEND AND UTILIZE SAME GAUGE/TYPE WIRING AS REQUIRED. 8. COORDINATE ROUTING AND LOCATION OF SHOWER LIGHT AND TRAP COORDINATE ROUTING AND LOCATION OF SHOWER LIGHT AND TRAP ASSEMBLY WITH PLUMBING CONTRACTOR. 9. DISCONNECT POWER TO EXISTING ELECTRIC RANGE. RECONNECT NEW DISCONNECT POWER TO EXISTING ELECTRIC RANGE. RECONNECT NEW EQUIPMENT AS SHOWN ON NEW PLAN. 10. RECONNECT POWER TO NEW ELECTRIC RANGE. COORDINATE WITH RECONNECT POWER TO NEW ELECTRIC RANGE. COORDINATE WITH EQUIPMENT PROVIDER. 11. PROVIDE NEW SWITCH FOR LIGHTING. RECONNECT TO EXISTING CIRCUIT. PROVIDE NEW SWITCH FOR LIGHTING. RECONNECT TO EXISTING CIRCUIT.
ROUND SURFACE LED DOWNLIGHT, 2450 LUMENS, 3500K, ARCHITECT TO SELECT FINISH.
AutoCAD SHX Text
SURFACE
AutoCAD SHX Text
FM119WR40R
AutoCAD SHX Text
SURFACE MOUNTED DOWNLIGHT LIGHTING FIXTURE AS SCHEDULED.
AutoCAD SHX Text
C
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
-
AutoCAD SHX Text
10
AutoCAD SHX Text
LED
AutoCAD SHX Text
120V
AutoCAD SHX Text
2' UNDERCABINET LED, ON/OFF ROCKER SWITCH.
AutoCAD SHX Text
SURFACE
AutoCAD SHX Text
UCEL 24IN 30K 90CRI SWR WH M6
AutoCAD SHX Text
%%UGENERAL NOTES:
AutoCAD SHX Text
A. THE REMOVAL DRAWINGS SHALL SERVE TO AID THE CONTRACTOR IN THE THE REMOVAL DRAWINGS SHALL SERVE TO AID THE CONTRACTOR IN THE EVALUATION OF THE EXTENT OF REMOVALS, BUT SHALL NOT BE HELD TO BE ALL INCLUSIVE. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE AREA TO BECOME THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE AREA TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. VERIFY SIZE, LOCATION, AND USAGE OF EXISTING UTILITIES PRIOR TO REMOVAL. FOR FURTHER INFORMATION WITH REGARD TO THE EXTENT OF REMOVALS, SEE THE CONSTRUCTION DRAWINGS AND THE ARCHITECTURAL DRAWINGS WHICH SHOW WORK TO BE PERFORMED. C. OWNER SHALL BE GIVEN FIRST CHOICE ON ALL EQUIPMENT BEING REMOVED THAT OWNER SHALL BE GIVEN FIRST CHOICE ON ALL EQUIPMENT BEING REMOVED THAT WILL NOT BE RELOCATED. CONTRACTOR SHALL REVIEW THE EXISTING EQUIPMENT WITH OWNER. EQUIPMENT BEING REMOVED OR RELOCATED SHALL BE REMOVED IN A MANNER THAT REUSE IS POSSIBLE AND STORED AS DIRECTED BY OWNER. ALL OTHER EQUIPMENT SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED & DISPOSED OF FROM THE SITE BY THE CONTRACTOR. D. IF EQUIPMENT TO REMAIN MUST BE REMOVED DUE TO REMOVAL OR IF EQUIPMENT TO REMAIN MUST BE REMOVED DUE TO REMOVAL OR CONSTRUCTION, THE EQUIPMENT SHALL BE RELOCATED IN A MANNER THAT IS ACCEPTABLE BY THE ARCHITECT/ENGINEER.