21
RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli (M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della Volpe, P. Iengo, S.Patricelli, G. Sekhniaidze)
Transcript
Page 1: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

RPC Cosmic Rays Test in Naples

Paolo Iengo Atlas RPC Group Napoli

(M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della Volpe, P.

Iengo, S.Patricelli, G. Sekhniaidze)

Page 2: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Outline

• The Test Stand

• The Test Procedure

• Examples of Test Results

• Statistic Distributions

• Conclusions

Page 3: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

The Test Stand

Page 4: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

ScintillatorsScintillators

Drift Chambers

Drift Chambers

The 2 modules housing The 2 modules housing

scintillators & tracking scintillators & tracking chambers are moved by chambers are moved by step motors automatically step motors automatically during data takingduring data taking

The Test Stand

Tracking system : 2 Drift Chambers 2x and 2y planes per layerSingle wire resolution ~400m

Trigger :TOP & BOTTOM layers 2 x 1 m2 scintillators

Page 5: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

The Test Procedure

• Preliminary Operations (cabling, flushing, leak test): 2 days

• Efficiency plateau at three different thresholds (0.7mV, 0.6mV, 0.5mV): 7 hours per th.

• Radiography: 50 hours

• Random trigger (single rate strip by strip): 3-4 hours

• Current & single rate scan at three different thresholds: 6-8 hours

• Data Analysis: 4 hours

It takes about 7-10 days to test a set of chambers (8 RPCs):

Page 6: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Parameters Monitoring

During the test the working and environment parameters (HV, gap and CAEN currents, gas flow, temperature, humidity,

atmospheric pressure etc.) are continuously monitored and stored in a dedicated database

Currents

Temperatures

Page 7: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Chambers Tested from Aug. 2002 to Feb. 2003

Up to now 83 chambers tested

Upgrade to 8 chambers on

the test stand

Upgrade to 8 chambers on

the test stand

Upgrade to 4 chambers on

the test stand

Upgrade to 4 chambers on

the test stand

Page 8: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Examples of Plateau

Fitted with Fermi’s function

Fitted with Fermi’s function

V0 is the HV at 50% of maximum efficiency A

V = 4 ln81/B is the difference between

HV at 90% and 10% of maximum efficiency

V0 is the HV at 50% of maximum efficiency A

V = 4 ln81/B is the difference between

HV at 90% and 10% of maximum efficiency

12.5 K (2.5K x 5) events per fixed HV and th

12.5 K (2.5K x 5) events per fixed HV and th

)( 01 VVBe

A

Page 9: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Plateau Statistics

Page 10: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Example of Cluster

Cluster Multiplicity

(1.1-1.3)

Cluster size for physical

cluster

(~2)

Cluster size for physical

cluster

(~2)

Cluster size for non physical cluster

(~1.5)Typical values at 10500 V and 0.5mV threshold

Page 11: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Gas Volume Radiography

1.25 M (250K x 5) events per fixed HV

and threshold

Efficiency of “golden tracks” selection ~

40%-50%

Inefficiency of gas volume (not neither

)

Measured inefficiencies (2%)

correspond to spacers and

frames.

Page 12: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Read-out panels radiography

Electronic

Inefficiency ( yes no and

viceversa)

Easy to see readout channels

with problems

Ineff. Points for Eta when Phi eff.

Ineff. Points for Phi when Eta eff.

Page 13: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Radiography Statistics (I)

Gas volume efficiencies obtained with radiography:

- White: GV OK

- Green: GV OK

(measurement affected by known problem)

- Red: GV to be replaced

Page 14: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Radiography Statistics (II)

Same as previous but with detail of known problem.

Page 15: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Radiography Statistics (III)

Page 16: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Radiography Statistics (V)

Page 17: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Single Rates

Page 18: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Currents Scan & Single Rates

Fitted with function:

I = a+bV + I0exp(V/k)

Fitted with function:

I = a+bV + I0exp(V/k)

Page 19: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Currents Scan Statistic

Gas Volume Rejected having too high

current

At HV = 10500 V

Page 20: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Conclusions

• RPC test in Naples are going on at a rate of about 8 chambers per week

• Up to now 83 BML-D chambers (out of 148) have been tested

• The test procedure allows to certificate each chamber analyzing all its working parameters (gas volume efficiency, electronics, currents, plateau etc)

• Tested chambers are stored in the test area in Naples, packed and ready to come to CERN, and….

Page 21: RPC Cosmic Rays Test in Naples Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino,R. de Asmundis, M. Della Pietra, D. della.

Conclusion(II)

…very soon we will have problem of storage space.