RPS/RKS Series
Adjustable DC Regulated Power Supply
Instruction Manual
HK LEE HING INDUSTRY CO., LIMITED
http://www.china-gauges.com/
2
2
3
4
8
9
10
10
CONTENTS
1、Overview
2、Specification
3、Parameter Specification
4、Panel control and indicator
5、Instructions
6、Maintenance
7、Fuse Replacement
8、Packing list
1
9 Maintenance、 card 11
http://www.china-gauges.com/
1、P
.
The RPS series
has the electric circuit protection function can stop the output and brings a
3.3V/5.0V/1A fixed output
Can work at the full load for a long time, can be used as a
regulated power supply or a stabilized current supply。
roduct Overview
RPS, RKS series adjustable dc regulated power supply is designed for
laboratory, school and the production line, the output voltage and load
current can be adjustable between 0 and the nominal value.
Stability and ripple coefficient is good can perfect
protection circuit.
RPS series is linear dc regulated power supply
RKS series is switch dc regulated power supply
2、Specification
RPS3003C 2-
RPS3003D 2-
RPS3005C 2-
RPS3005D 2-
RPS6002C 2-
RPS6002D 2-
RPS6003C 2-
RPS6005C 2-
RPS6003D 2-
RPS6005D 2-
RPS3010D 2-
RPS3020D 2-
RPS3030D 2-
RKS3010D
RKS3020D
RKS3030D
RKS6020D
RKS6030D
RKS6040D
RKS6050D
RKS6060D
Model Voltage current External circuitprotection features
3 3V 5V 1A. / /Fixed output Display
0 30V~
0 30V~
0 30V~
0 30V~
0 60V~
0 60V~
0 60V~
0 60V~
0 60V~
0 60V~
0 30V~
0 30V~
0 30V~
0 30V~
0 30V~
0 30V~
0 60V~
0 60V~
0 60V~
0 60V~
0 60V~
0 3A~
0 3A~
0 5A~
0 5A~
0 2A~
0 2A~
0 3A~
0 5A~
0 3A~
0 5A~
0 10A~
0 20A~
0 30A~
0 10A~
0 20A~
0 30A~
0 20A~
0 30A~
0 40A~
0 50A~
0 60A~
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
A
CURRENT
V
VOLTAGE
A
CURRENT
V
VOLTAGE
A
CURRENT
V
VOLTAGE
2
http://www.china-gauges.com/
[3-1]
[3-2]
[3-3] Steady voltage working status:
(
( )
( ) ≤3mArms/5
( ) ≤0.2%+3mA/5
≤0.2%+3mA/5
( )
( ) :
≤0.01%+3mV
≤0.01%+3mV( ~ )
≤0.01%+5mV( ~ )
( ) :
≤100μS( )
≤0.5mVrms(5Hz~1MHz)
≤1.0mVrms(5Hz~1MHz)
≤3000PPM/℃
1
2 mArms
3 mA
mA
1
2 Voltage
Voltage
0 30V
0 60V
3
( ) :
( )
4
5
Rated working conditions
Steady current working status:
1) power supply voltage 220 v + 10% for 50 hz 60 hz
(2) working conditions: temperature: 0 to 40 , relative
humidity: < 80% RH
(3) storage conditions: temperature: - 10 ~ 70 Relative
humidity: < 70% RH
(4) the output mode (see product specification)
℃ ℃
℃ ℃;
the output current is adjustable from 0
between nominal value
Ripple noise
Current stabilityCurrent stability
Load stability
the output voltage is adjustable from 0 between
nominal value
stability
stability
Load stability
Load stability
Recovery time
50% load changes, minimum load current 0.5 A
Ripple noise
temperature coefficient
3 Parameter Specification、
4、Panel control and indicator
3
http://www.china-gauges.com/
18 19
20
21
CURRENT VOLTAGE
C C. .C C. . C V. .C V. .
FINE COARSE FINE COARSE
OUTPUT
ONOFF
3 3V.3 3V.5 0V.5 0V.
3 3V.3 3V.5 0V.5 0V. 30V5A
GND
RPS3005C 2 DC POWER SUPPLY-RPS3005C 2 DC POWER SUPPLY-RekR
1 11 12 13 14 15
4
5
10
9
2
3
6
7
8
16 17
POWER
A
CURRENT
V
VOLTAGE
4
http://www.china-gauges.com/
18 19
20
21
CURRENT VOLTAGE
C C. .C C. . C V. .C V. .
FINE COARSE FINE COARSE
OUTPUT
ONOFF
3 3V.3 3V.5 0V.5 0V.
3 3V.3 3V.5 0V.5 0V. 30V5A
GND
RPS3005D 2 DC POWER SUPPLY-RPS3005D 2 DC POWER SUPPLY-RekR
1 11 12 13 14 15
4
5
10
9
2
3
6
7
8
16 17
POWER
A
CURRENT
V
VOLTAGE
5
http://www.china-gauges.com/
1 11 12 13 14 15
4
5
10
9
2
3
6
7
8
16 17
CURRENT VOLTAGE
C C. .C C. . C V. .C V. .
FINE COARSE FINE COARSE
OUTPUT
ONOFF
3 3V.3 3V.5 0V.5 0V.
3 3V.3 3V.5 0V.5 0V. 60V5A
GND
RPS6005D 2 DC POWER SUPPLY-RPS6005D 2 DC POWER SUPPLY-RekR
POWER
A V
CURRENT VOLTAGE
22 23
20
19
18
21
6
http://www.china-gauges.com/
11 12 13 14 154 5
10 9
6
7816 17
C C. .C C. . C V. .C V. .
CURRENT VOLTAGE
FINE COARSE FINE COARSE
OFFON
POWER GND
3 3V.3 3V.5 0V.5 0V.
3 3V.3 3V.5 0V.5 0V.
ÀZ[X�Á �10A
ÃZ[Ä�ÅXÆTÇÈWhen using the current greater than 10A
Please use the terminals on the rear panel
É ÊATTENTION
R
Rek RPS3030D 2 DC POWER SUPPLY-RPS3030D 2 DC POWER SUPPLY-
A V
CURRENT VOLTAGE
1
1921 15
7
23
OUTPUT
2013
http://www.china-gauges.com/
13 14 155
10 9
6
7816 17
C C. .C C. . C V. .C V. .
CURRENT VOLTAGE
FINE COARSE FINE COARSE
OFFON
POWER GND
ÀZ[X�Á �10A
ÃZ[Ä�ÅXÆTÇÈWhen using the current greater than 10A
Please use the terminals on the rear panel
É ÊATTENTION
R
Rek RKS3030D DC POWER SUPPLY
A V
CURRENT VOLTAGE
1
19 2021 15 13
8
http://www.china-gauges.com/
5、Instructions
[5-1] Cautions
1、
switch to 110V:110V 1 0%60Hz。
switch to 0V: 0V 1 0% 0Hz。
、
Ac input according to the rear panel (110V/ 220V switch):
22 22 5
2 do not use where the environmental temperature 40 ,
the fan is located in the instrument back, should leave
enough space.
3 the output voltage overshoot: when switching power supply,
the output voltage is less than the preset.
℃
、
①、
②、
③、
④、 ≤ )
⑤、
⑥、
⑦、
⑧、
⑨、
⑩、
、 . / . “-”
、 . / . “+”
、“-”
、“ ”
、“+”
、
、
、
、
、
、
、
[4-1] the Panel Description:
voltage output indicator light
3.3V/5.0V switch (output accuracy 1%
Current adjustment roughly
Current adjustment
3 3V 5 0V
3 3V 5 0V
GND
F
the power switch
control switch, voltage output
stable current indicator light
stable voltage indicator light
Voltage adjustment roughly
Voltage adjustment fine-tuned
fine-tuned
output port
output port
Output: negative polarity (black)
output: grounding (green)
Output: positive polarity (red)
Current output display (display accuracy of 2% or less + 2 d)
Voltage output display (display accuracy of 1% or less + 2 d)
110 V / 220 V switch (according to clients' need)
Fuse box
power socket
an (fan with temperature control, when the internal
temperature up to 60 + 5 would working℃ ℃ )
11
12
13
14
15
16
17
18
19
20
21
9
http://www.china-gauges.com/
6 Maintenance、1
2
3
、 。
、
、
。
Please pull out the plug before clean
With neutral detergent and water to wet soft cloth to
wipe the instrument,do not spray cleaner directly on the
instrument.
Do not use solvent containing hydrocarbons, chloride,
or similar, also do notuse detergent containing grinding
ingredients
[5-2] :
[5-3]
[5-4] Working:
1、
2、
3、
4、
5、
6、
、
Adjust the current knob to the desired current value
Current value (overload protection) has been set, then do not
5
,
,
,
, ,
,
、
、 。
、
、
It can vary with the load at constant voltage and constant
current state of continuous transformation.
CV
1
2
3 input power and
4
Limiting current Settings
The characteristics of constant voltage/current
Decisions a maximum safe current for your instruments
The power supply with a shorter route temporarily (+) and (-)
terminal short circuit.(the voltage must be adjusted below 10 v)
Rotating voltage control knob until the CC indicator bright
change the current knob
Remove the short circuit, can enter the working state.
required VOLTAGE and CURRENT value.
external loads connected "+", "-" output terminals.
This series of characteristics of the power supply is
called constantvoltage/ current type automatic conversion
For example, if the load to make the power work in constant
voltage mode, just output stabilityConstant voltage As the
load increases, the output voltage will remain stable
Until you reach the preset current limit value After arrived
at current limit value Output current is stable The output
voltage is inversely proportional to the load indicator
bright means constant voltage and CC indicator bright means
constant current.
Put the power switch in "OFF" position.
to ensure that the input voltage.
put the power switch in "ON" position
adjust the "VOLTAGE" and "CURRENT" knob to the
.
10
http://www.china-gauges.com/
Fuse holder on the power socket
。
Replacing the fuse method:Remove the power plug,In accordance with the view to open the fuse holder
Replace the same specifications of fuseand then install the fuse holder back in.
7、Fuse Replacement
,If the fuse blew out Regulated power supply will stop working.
8、1 power supply
2
3 Users manual x 1
4 operation guide
5
、 ;
、 ;
、 ;
、 ;
、 。
x 1
x 1
x 1
x 1
Packing list
power cord
Certificate of approval
Product Warranty
、
、 ,
:
、 :
、
:
、
:
b non normal use such as improper operation of devices,
the improper maintenance, modification or adjustment
c
d
2
1, product since the acquisition date within one year free maintenance
services. Except for the following conditions:
a fail to produce the product warranty card:
consumptive material is beyond the scope of warranty:
Belong to an irresistible natural disasters, such as flood,
fire, earthquake, etc
More than warranty repair charge upkeep, users to pay for due to
maintenance
11