Heavy Duty Submersible Slurry Pumps For Industrial Applications www.keystonepumps.com
Transcript
Page 1: Run Dry Slurry Seal Heavy Duty Submersible Slurry Pumps ...HDS 100M HDS 150M HDS 200M HDS 250L C M Y CM MY CY CMY K Keystone_Brochure_PRINT.pdf 2 13-07-31 10:52 AM Keystone HDS Low-Head

Heavy Duty Submersible Slurry Pumps For Industrial Applications

STANDARD HDS FEATURES

Run Dry Slurry Seal

Mechanical seal configuration designed for prolonged motor operation in severe duty slurry applications

Double mechanical seals operate in an oil chamber where components are isolated from the pumped slurry

Carbon-Ni Resist face (upper) & Tungsten Carbide face (lower) w/ stainless hardware

Particle Ejection Ports

Expels solids to extend seal life

Maintains minimum flow during closed valve operation

HDS Agitator

Solids are propelled into suspension by the mixing

action of the blades

Heavy Duty XP Seal

Carbon-Ni Resist faces & 316 Stainless Steel hardware for internal seal

Tungsten Carbide faces & 316 StainlessSteel hardware for external seal

Seal Leak Detector

Senses moisture if the external seal fails and sends a signal to the control panel

Water Jacket

Provides motor cooling for run dry & hot sump applications

www.keystonepumps.com

Control Panel

Simplex / Duplex

Ground Fault & Ground Check Monitoring

Custom Designs Available

Jet Ring

Settled solids are induced into suspension

by the water jetting action of the nozzles

Lifting Bail

Allows for a central lift point / Low temperature operation design

OPTIONAL HDS FEATURES

Unit 307 – 2999 Underhill AveBurnaby, B.C. V5A 3C2

Toll-free: 1.888.875.3323Phone: 604.227.3555

Fax: 604.229.0494Email: [email protected]

www.keystonepumps.com2013 Keystone Pumps, All rights reserved

C

M

Y

CM

MY

CY

CMY

K

Keystone_Brochure_PRINT.pdf 1 13-07-31 10:52 AM

Page 2: Run Dry Slurry Seal Heavy Duty Submersible Slurry Pumps ...HDS 100M HDS 150M HDS 200M HDS 250L C M Y CM MY CY CMY K Keystone_Brochure_PRINT.pdf 2 13-07-31 10:52 AM Keystone HDS Low-Head

Keystone HDS Low-Head Hydraulic Performance

Discharge Size [in. (mm)] 2" (50)Impeller Diameter [in. (mm)] 8.46" (215)Min. Impeller Diameter [in. (mm)] 6.77" (172)Max Solid Size in. (mm) 0.63" (16)Motor Frame Size 180TY / 210TYSMotor Power HP 5 / 7.5 / 10 / 15 / 20Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 180 TY - 349 (159) / 210 TYS - 464 (211) Discharge Size [in. (mm)] 3" (75)Impeller Diameter [in. (mm)] 8.46" (215)Min. Impeller Diameter [in. (mm)] 6.77" (172)Max Solid Size in. (mm) 0.86" (22)Motor Frame Size 180TY / 210TYSMotor Power HP 5 / 7.5 / 10 / 15 / 20Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 180TY - 371 (168) / 210TYS - 484 (221) Discharge Size [in. (mm)] 4" (100)Impeller Diameter [in. (mm)] 9.05" (230)Min. Impeller Diameter [in. (mm)] 7.24" (184)Max Solid Size in. (mm) 1.26" (32)Motor Frame Size 180TY / 210TYSMotor Power HP 5 / 7.5 / 10 / 15 / 20Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 180TY - 403 (182) / 210TYS - 518 (235) Discharge Size [in. (mm)] 6" (150)Impeller Diameter [in. (mm)] 9.84" (250)Min. Impeller Diameter [in. (mm)] 7.82" (200)Max Solid Size in. (mm) 1.26" (32)Motor Frame Size 250TY / 320TYSMotor Power HP 25 / 30 / 40 / 50 / 60 / 75Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 250TY - 1058 (482) / 320TYS - 1461 (664) Discharge Size [in. (mm)] 8" (200)Impeller Diameter [in. (mm)] 14.76" (375)Min. Impeller Diameter [in. (mm)] 11.81" (300)Max Solid Size in. (mm) 1.58" (32)Motor Frame Size 320TY / 360TYS / L360TYSMotor Power HP 40 / 50 / 60 / 75 / 100 / 125 / 150 Freq [(Hz) / RPM]¹ (60) / 900 & 1200Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 320TY - 2015 (916) / L360TYS - 2430 (1100) Discharge Size [in. (mm)] 10" (250)Impeller Diameter [in. (mm)] 20.47" (520)Min. Impeller Diameter [in. (mm)] 16.37" (416)Max Solid Size in. (mm) 2.2" (56)Motor Frame Size 360TYS / L360TYSMotor Power HP 100 / 125 / 150Freq [(Hz) / RPM]¹ (60) / 900Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] L360TYS - 3115 (1416)

FEET

GPM

100

90

80

70

60

50

40

30

20

10

0

100

HD

S 50

L

HD

S 75

L

HD

S 10

0 L

HD

S 15

0 L

HD

S 20

0 L

HD

S 25

0 L

200300

400500

7501000

15002000

30005000

7500

Discharge Size [in. (mm)] 3" (75)Impeller Diameter [in. (mm)] 13.38" (340)Min. Impeller Diameter [in. (mm)] 10.70" (272)Max Solid Size in. (mm) 1.38" (35)Motor Frame Size 250TY / 320TYSMotor Power HP 25 / 30 / 40 / 50 / 60 / 75Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 250TY - 747 (340) / 320TYS - 1347 (613) Discharge Size [in. (mm)] 4" (100)Impeller Diameter [in. (mm)] 13.38" (340)Min. Impeller Diameter [in. (mm)] 10.70" (272)Max Solid Size in. (mm) 1.56" (40)Motor Frame Size 250TY / 320TYSMotor Power HP 25 / 30 / 40 / 50 / 60 / 75Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 250TY - 790 (359) / 320TYS - 1489 (677) Discharge Size [in. (mm)] 6" (150)Impeller Diameter [in. (mm)] 16.93" (430)Min. Impeller Diameter [in. (mm)] 13.60" (345)Max Solid Size in. (mm) 2.16" (55)Motor Frame Size 320TY / 360 TYS / L360TYSMotor Power HP 40 / 50 / 60 / 75 / 100 / 125 / 150 Freq [(Hz) / RPM]¹ (60) / 900 & 1200Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 320TY - 2216 (1007) / L360TYS - 2633 (1192) Discharge Size [in. (mm)] 8" (200)Impeller Diameter [in. (mm)] 18.50" (470)Min. Impeller Diameter [in. (mm)] 14.80" (376)Max Solid Size in. (mm) 2.36" (60)Motor Frame Size 320TY / 360TYS / L360TYSMotor Power HP 40 / 50 / 60 / 75 / 100 / 125 / 150 Freq [(Hz) / RPM]¹ (60) / 900 & 1200Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 320TY - 2333 (1056) / L360TYS - 2750 (1244)

150# ANSI “B 16.5” Flange

ASTM A532 CI. III Type AHigh Chrome Constructionfor Liquid End Components

Power and Control Cable Entry

Thermal Overload Sensors

416 Stainless Steel Shaft(17-4 PH & 316SS Optional)

Optional Explosion-Proof MotorEnclosure per Class 1 Groups C&D(UL Listed and CSA Certified)

Bearing Box with Heavy-Duty BallBearings Sealed and Greased for life

Dual Moisture Sensor Probes

Integrated Lifting Points(Optional Lifting Bail Available)

F Class Installation Standard(H Optional & 90°C High

Ambient Models Available)

Heavy-Duty Cast Ductile IronMotor Housing Components

Particle Ejection Ports

Internal Slurry (Continuous Run DryCapable) or Explosion-Proof Seal

316 Stainless Steel & 17-4 PHNon-Cast Wet End Components Standard

(Alloy 2205 Optional)

Agitator

Screened Inlet

POWER GENERATION

– Coal Pile Runoff– Coal Crusher Sumps– Coal Tunnel Sumps– Coal Fines Recovery– FGD Blowdown Sumps– Bottom Ash Transport– Fly Ash Sumps and Ponds– Wastewater and Basement Sumps

SAND & GRAVEL

– Weir Overflow– Dust Suppression– Recycle Water– Wheel Wash Pump– Cyclone Feed– Dredging– Barge Unloading

PUMP & PAPER / FOOD PROCESSING

– Wood Yard Runoff– Wastewater and Basement Sumps– Food Processing Waste– Juicer Sumps

MINING / STEEL

– Mine Dewatering– Collection & Runoff Sumps– Emergency Dump Pond– Tailings Pond Cleanout– Kaolin Clay– Red Mud Recovery– Magnetite Recovery– Clarifier Sludge– Slag Pits– Scale Pits– Swarf Boxes– Flume Flushers– Interceptor Pumps

Keystone HDS Medium-Head Hydraulic Performance

FEET

GPM

220

200

180

160

140

120

100

80

60

40

0

100

HD

S 75

M

HD

S 10

0 M

HD

S 15

0 M

HD

S 20

0 M

200300

400500

7501000

15002000

25003000

4000

The Keystone HDS delivers continuous, heavy-duty performance with a full range of design options. Built to handle your toughest applications!

Standard Features

316 Stainless Steel & 17-4 PH Hardware

High Chrome IronConstruction

Particle Ejection Ports

Agitator

Internal Slurry Seal

316 Stainless SteelFasteners Standard

1 50 HZ Frequency Available2 Class F- 120°F Class H- 160°F High Ambient-190°F3 Weight Subject to Motor Size

HD

S 50

LH

DS

75L

HD

S 10

0LH

DS

150L

HD

S 20

0L

HD

S 75

MH

DS

100M

HD

S 15

0MH

DS

200M

HD

S 25

0L

C

M

Y

CM

MY

CY

CMY

K

Keystone_Brochure_PRINT.pdf 2 13-07-31 10:52 AM

Page 3: Run Dry Slurry Seal Heavy Duty Submersible Slurry Pumps ...HDS 100M HDS 150M HDS 200M HDS 250L C M Y CM MY CY CMY K Keystone_Brochure_PRINT.pdf 2 13-07-31 10:52 AM Keystone HDS Low-Head

Keystone HDS Low-Head Hydraulic Performance

Discharge Size [in. (mm)] 2" (50)Impeller Diameter [in. (mm)] 8.46" (215)Min. Impeller Diameter [in. (mm)] 6.77" (172)Max Solid Size in. (mm) 0.63" (16)Motor Frame Size 180TY / 210TYSMotor Power HP 5 / 7.5 / 10 / 15 / 20Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 180 TY - 349 (159) / 210 TYS - 464 (211) Discharge Size [in. (mm)] 3" (75)Impeller Diameter [in. (mm)] 8.46" (215)Min. Impeller Diameter [in. (mm)] 6.77" (172)Max Solid Size in. (mm) 0.86" (22)Motor Frame Size 180TY / 210TYSMotor Power HP 5 / 7.5 / 10 / 15 / 20Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 180TY - 371 (168) / 210TYS - 484 (221) Discharge Size [in. (mm)] 4" (100)Impeller Diameter [in. (mm)] 9.05" (230)Min. Impeller Diameter [in. (mm)] 7.24" (184)Max Solid Size in. (mm) 1.26" (32)Motor Frame Size 180TY / 210TYSMotor Power HP 5 / 7.5 / 10 / 15 / 20Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 180TY - 403 (182) / 210TYS - 518 (235) Discharge Size [in. (mm)] 6" (150)Impeller Diameter [in. (mm)] 9.84" (250)Min. Impeller Diameter [in. (mm)] 7.82" (200)Max Solid Size in. (mm) 1.26" (32)Motor Frame Size 250TY / 320TYSMotor Power HP 25 / 30 / 40 / 50 / 60 / 75Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 250TY - 1058 (482) / 320TYS - 1461 (664) Discharge Size [in. (mm)] 8" (200)Impeller Diameter [in. (mm)] 14.76" (375)Min. Impeller Diameter [in. (mm)] 11.81" (300)Max Solid Size in. (mm) 1.58" (32)Motor Frame Size 320TY / 360TYS / L360TYSMotor Power HP 40 / 50 / 60 / 75 / 100 / 125 / 150 Freq [(Hz) / RPM]¹ (60) / 900 & 1200Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 320TY - 2015 (916) / L360TYS - 2430 (1100) Discharge Size [in. (mm)] 10" (250)Impeller Diameter [in. (mm)] 20.47" (520)Min. Impeller Diameter [in. (mm)] 16.37" (416)Max Solid Size in. (mm) 2.2" (56)Motor Frame Size 360TYS / L360TYSMotor Power HP 100 / 125 / 150Freq [(Hz) / RPM]¹ (60) / 900Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] L360TYS - 3115 (1416)

FEET

GPM

100

90

80

70

60

50

40

30

20

10

0

100

HD

S 50

L

HD

S 75

L

HD

S 10

0 L

HD

S 15

0 L

HD

S 20

0 L

HD

S 25

0 L

200300

400500

7501000

15002000

30005000

7500

Discharge Size [in. (mm)] 3" (75)Impeller Diameter [in. (mm)] 13.38" (340)Min. Impeller Diameter [in. (mm)] 10.70" (272)Max Solid Size in. (mm) 1.38" (35)Motor Frame Size 250TY / 320TYSMotor Power HP 25 / 30 / 40 / 50 / 60 / 75Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 250TY - 747 (340) / 320TYS - 1347 (613) Discharge Size [in. (mm)] 4" (100)Impeller Diameter [in. (mm)] 13.38" (340)Min. Impeller Diameter [in. (mm)] 10.70" (272)Max Solid Size in. (mm) 1.56" (40)Motor Frame Size 250TY / 320TYSMotor Power HP 25 / 30 / 40 / 50 / 60 / 75Freq [(Hz) / RPM]¹ (60) / 1200 & 1800Voltage 230 / 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 250TY - 790 (359) / 320TYS - 1489 (677) Discharge Size [in. (mm)] 6" (150)Impeller Diameter [in. (mm)] 16.93" (430)Min. Impeller Diameter [in. (mm)] 13.60" (345)Max Solid Size in. (mm) 2.16" (55)Motor Frame Size 320TY / 360 TYS / L360TYSMotor Power HP 40 / 50 / 60 / 75 / 100 / 125 / 150 Freq [(Hz) / RPM]¹ (60) / 900 & 1200Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 320TY - 2216 (1007) / L360TYS - 2633 (1192) Discharge Size [in. (mm)] 8" (200)Impeller Diameter [in. (mm)] 18.50" (470)Min. Impeller Diameter [in. (mm)] 14.80" (376)Max Solid Size in. (mm) 2.36" (60)Motor Frame Size 320TY / 360TYS / L360TYSMotor Power HP 40 / 50 / 60 / 75 / 100 / 125 / 150 Freq [(Hz) / RPM]¹ (60) / 900 & 1200Voltage 460 / 575Insulation² F / H / High AmbientWeight³ [lbs. (kg)] 320TY - 2333 (1056) / L360TYS - 2750 (1244)

150# ANSI “B 16.5” Flange

ASTM A532 CI. III Type AHigh Chrome Constructionfor Liquid End Components

Power and Control Cable Entry

Thermal Overload Sensors

416 Stainless Steel Shaft(17-4 PH & 316SS Optional)

Optional Explosion-Proof MotorEnclosure per Class 1 Groups C&D(UL Listed and CSA Certified)

Bearing Box with Heavy-Duty BallBearings Sealed and Greased for life

Dual Moisture Sensor Probes

Integrated Lifting Points(Optional Lifting Bail Available)

F Class Installation Standard(H Optional & 90°C High

Ambient Models Available)

Heavy-Duty Cast Ductile IronMotor Housing Components

Particle Ejection Ports

Internal Slurry (Continuous Run DryCapable) or Explosion-Proof Seal

316 Stainless Steel & 17-4 PHNon-Cast Wet End Components Standard

(Alloy 2205 Optional)

Agitator

Screened Inlet

POWER GENERATION

– Coal Pile Runoff– Coal Crusher Sumps– Coal Tunnel Sumps– Coal Fines Recovery– FGD Blowdown Sumps– Bottom Ash Transport– Fly Ash Sumps and Ponds– Wastewater and Basement Sumps

SAND & GRAVEL

– Weir Overflow– Dust Suppression– Recycle Water– Wheel Wash Pump– Cyclone Feed– Dredging– Barge Unloading

PUMP & PAPER / FOOD PROCESSING

– Wood Yard Runoff– Wastewater and Basement Sumps– Food Processing Waste– Juicer Sumps

MINING / STEEL

– Mine Dewatering– Collection & Runoff Sumps– Emergency Dump Pond– Tailings Pond Cleanout– Kaolin Clay– Red Mud Recovery– Magnetite Recovery– Clarifier Sludge– Slag Pits– Scale Pits– Swarf Boxes– Flume Flushers– Interceptor Pumps

Keystone HDS Medium-Head Hydraulic Performance

FEET

GPM

220

200

180

160

140

120

100

80

60

40

0

100

HD

S 75

M

HD

S 10

0 M

HD

S 15

0 M

HD

S 20

0 M

200300

400500

7501000

15002000

25003000

4000

The Keystone HDS delivers continuous, heavy-duty performance with a full range of design options. Built to handle your toughest applications!

Standard Features

316 Stainless Steel & 17-4 PH Hardware

High Chrome IronConstruction

Particle Ejection Ports

Agitator

Internal Slurry Seal

316 Stainless SteelFasteners Standard

1 50 HZ Frequency Available2 Class F- 120°F Class H- 160°F High Ambient-190°F3 Weight Subject to Motor Size

HD

S 50

LH

DS

75L

HD

S 10

0LH

DS

150L

HD

S 20

0L

HD

S 75

MH

DS

100M

HD

S 15

0MH

DS

200M

HD

S 25

0L

C

M

Y

CM

MY

CY

CMY

K

Keystone_Brochure_PRINT.pdf 2 13-07-31 10:52 AM

Page 4: Run Dry Slurry Seal Heavy Duty Submersible Slurry Pumps ...HDS 100M HDS 150M HDS 200M HDS 250L C M Y CM MY CY CMY K Keystone_Brochure_PRINT.pdf 2 13-07-31 10:52 AM Keystone HDS Low-Head

Heavy Duty Submersible Slurry Pumps For Industrial Applications

STANDARD HDS FEATURES

Run Dry Slurry Seal

Mechanical seal configuration designed for prolonged motor operation in severe duty slurry applications

Double mechanical seals operate in an oil chamber where components are isolated from the pumped slurry

Carbon-Ni Resist face (upper) & Tungsten Carbide face (lower) w/ stainless hardware

Particle Ejection Ports

Expels solids to extend seal life

Maintains minimum flow during closed valve operation

HDS Agitator

Solids are propelled into suspension by the mixing

action of the blades

Heavy Duty XP Seal

Carbon-Ni Resist faces & 316 Stainless Steel hardware for internal seal

Tungsten Carbide faces & 316 StainlessSteel hardware for external seal

Seal Leak Detector

Senses moisture if the external seal fails and sends a signal to the control panel

Water Jacket

Provides motor cooling for run dry & hot sump applications

www.keystonepumps.com

Control Panel

Simplex / Duplex

Ground Fault & Ground Check Monitoring

Custom Designs Available

Jet Ring

Settled solids are induced into suspension

by the water jetting action of the nozzles

Lifting Bail

Allows for a central lift point / Low temperature operation design

OPTIONAL HDS FEATURES

Unit 307 – 2999 Underhill AveBurnaby, B.C. V5A 3C2

Toll-free: 1.888.875.3323Phone: 604.227.3555

Fax: 604.229.0494Email: [email protected]

www.keystonepumps.com2013 Keystone Pumps, All rights reserved

C

M

Y

CM

MY

CY

CMY

K

Keystone_Brochure_PRINT.pdf 1 13-07-31 10:52 AM


Recommended