Date post: | 21-Jan-2016 |
Category: |
Documents |
Upload: | thomasina-horn |
View: | 222 times |
Download: | 0 times |
Running SPD
OUTLINE
• VFE and CB overview• Mapping• CB panel:
- Regulator board tab: how to switch ON/OFF the VFEs
- Control tab: how to mask VFE- Test tab: how to check VFE status
21/October/2008 SPD CB and VFE - Piquet Training
2
SPD VFE and CB overview
PMT 64ch
SPD
VFE
CLOCK
ctrl
x100 x16
Digital FE
Control Board
Trigger path
DAQ pathx100
...
6016 cells
Optical fibers
DETECTOR VFE boxes FE crates~20 m (top) ~30 m bottom
Multiplicity Trigger
PRS Crate:14FE + 2CBor 8FE + 2CB
Regulators Board
x16
7ch
8ch
Maraton PS
Ch 0 to 5
HV system
Boards 7 to 11
ctrl
On PRS1 and PRS6, CB channels
used for RB
21/October/2008 SPD CB and VFE - Piquet Training
3
Mapping: VFE number
21/October/2008 SPD CB and VFE - Piquet Training
4
Mapping: CB channels vs. detector
BEAM
1
2
3
4
5
6
7
1
2
3
4
5
6
7
0
1
2
3
4
5
6
0
1
2
3
4
5
6
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
SM1 SM2 SM3 SM4 SM5 SM6 SM7 SM8
1
2
3
4
5
6
7
0
1
2
3
4
5
6
1
234
5
6
701
2
34
5
6
1
2
3
4
5
6
7
1
2
3
4
5
6
7
2
345
6
5
670
1
12
3
4
PRS0 CB5
PRS0 CB16
PRS1 CB5
PRS1 CB16PRS2 CB5PRS2 CB16
PRS3 CB5
PRS3 CB16
PRS4 CB5
PRS4 CB16
PRS5 CB5
PRS5 CB16PRS6 CB5PRS6 CB16
PRS7 CB5
PRS7 CB16
21/October/2008 SPD CB and VFE - Piquet Training
5
Mapping: CB channels, VFE, and RB
slotCB ch
0 C 5 0
0 C 5 1 VFE 1
0 C 5 2 VFE 2
0 C 5 3 VFE 3
0 C 5 4 VFE 4
0 C 5 5 VFE 5
0 C 5 6 VFE 6
0 C 5 7 VFE 7
0 C 16 0 VFE 8
0 C 16 1 VFE 9
0 C 16 2 VFE 10
0 C 16 3 VFE 11
0 C 16 4 VFE 12
0 C 16 5 VFE 13
0 C 16 6 VFE 14
0 C 16 7
1 C 5 0 RB
1 C 5 1 RB
1 C 5 2 RB
1 C 5 3 RB
1 C 5 4 VFE 20
1 C 5 5 VFE 21
1 C 5 6 VFE 22
1 C 5 7 VFE 23
1 C 16 0 VFE 24
1 C 16 1 VFE 25
1 C 16 2 VFE 26
1 C 16 3 VFE 27
1 C 16 4 RB
1 C 16 5 RB
1 C 16 6 RB
1 C 16 7 RB
VFE cond DB
CRATEA/C
SIDE
CBVFE or RB slot
CB ch
2 C 5 0
2 C 5 1 VFE 33
2 C 5 2 VFE 34
2 C 5 3 VFE 35
2 C 5 4 VFE 36
2 C 5 5 VFE 37
2 C 5 6 VFE 38
2 C 5 7 VFE 39
2 C 16 0 VFE 40
2 C 16 1 VFE 41
2 C 16 2 VFE 42
2 C 16 3 VFE 43
2 C 16 4 VFE 44
2 C 16 5 VFE 45
2 C 16 6 VFE 46
2 C 16 7
3 C 5 0
3 C 5 1 VFE 49
3 C 5 2 VFE 50
3 C 5 3 VFE 51
3 C 5 4 VFE 52
3 C 5 5 VFE 53
3 C 5 6 VFE 54
3 C 5 7 VFE 55
3 C 16 0 VFE 56
3 C 16 1 VFE 57
3 C 16 2 VFE 58
3 C 16 3 VFE 59
3 C 16 4 VFE 60
3 C 16 5 VFE 61
3 C 16 6 VFE 62
3 C 16 7
VFE cond DB
CRATEA/C
SIDE
CBVFE or RB slot
CB ch
4 A 5 0
4 A 5 1 VFE 65
4 A 5 2 VFE 66
4 A 5 3 VFE 67
4 A 5 4 VFE 68
4 A 5 5 VFE 69
4 A 5 6 VFE 70
4 A 5 7 VFE 71
4 A 16 0 VFE 72
4 A 16 1 VFE 73
4 A 16 2 VFE 74
4 A 16 3 VFE 75
4 A 16 4 VFE 76
4 A 16 5 VFE 77
4 A 16 6 VFE 78
4 A 16 7
5 A 5 0
5 A 5 1 VFE 81
5 A 5 2 VFE 82
5 A 5 3 VFE 83
5 A 5 4 VFE 84
5 A 5 5 VFE 85
5 A 5 6 VFE 86
5 A 5 7 VFE 87
5 A 16 0 VFE 88
5 A 16 1 VFE 89
5 A 16 2 VFE 90
5 A 16 3 VFE 91
5 A 16 4 VFE 92
5 A 16 5 VFE 93
5 A 16 6 VFE 94
5 A 16 7
VFE cond DB
CRATEA/C
SIDE
CBVFE or RB slot
CB ch
6 A 5 0 RB
6 A 5 1 RB
6 A 5 2 RB
6 A 5 3 RB
6 A 5 4 VFE 100
6 A 5 5 VFE 101
6 A 5 6 VFE 102
6 A 5 7 VFE 103
6 A 16 0 VFE 104
6 A 16 1 VFE 105
6 A 16 2 VFE 106
6 A 16 3 VFE 107
6 A 16 4 RB 108
6 A 16 5 RB 109
6 A 16 6 RB 110
6 A 16 7 RB 111
7 A 5 0
7 A 5 1 VFE 113
7 A 5 2 VFE 114
7 A 5 3 VFE 115
7 A 5 4 VFE 116
7 A 5 5 VFE 117
7 A 5 6 VFE 118
7 A 5 7 VFE 119
7 A 16 0 VFE 120
7 A 16 1 VFE 121
7 A 16 2 VFE 122
7 A 16 3 VFE 123
7 A 16 4 VFE 124
7 A 16 5 VFE 125
7 A 16 6 VFE 126
7 A 16 7
VFE cond DB
CRATEA/C
SIDE
CBVFE or RB
21/October/2008 SPD CB and VFE - Piquet Training
6
SPD CB panel
21/October/2008 SPD CB and VFE - Piquet Training
7
SPD CB panel: regulator board tab
Select “Reguladores” tab
“Reguladores” tab is not used except on
crates PRS1 and PRS6
21/October/2008 SPD CB and VFE - Piquet Training
8
SPD CB panel: switch ON/OFF the VFEs
Select “Reguladores” tab
Regulator Board control channels are highlighted
in green
Clicking on these buttons, VFE regulators are switched ON/OFF
Select the channels
only for crates PRS1 and PRS6
21/October/2008 SPD CB and VFE - Piquet Training
9
SPD CB panel: control tab
After going to “READY”, VFE correctly configured are in
green
Grey color is for unused CB channels
21/October/2008 SPD CB and VFE - Piquet Training
10
Crate PSR1, with RB
SPD CB panel: control tab
After going to “READY”, VFE correctly configured are in
green
Grey color is for unused CB channels
21/October/2008 SPD CB and VFE - Piquet Training
11
SPD CB panel: control tab
If ERROR, VFEs appear in red color
21/October/2008 SPD CB and VFE - Piquet Training
12
SPD CB panel: how to mask
(1) Check the CB channels
(2) Click “Refresh mask”
(3) Click “Refresh text”VFEs will appear in blue
(4) “Init VFE mask” returns to initial masked channels (if
needed)
21/October/2008 SPD CB and VFE - Piquet Training
13
SPD CB panel: read and apply recipes
Select “CONTROL” tab
Generate recipe: Read new recipe
text file
Apply new recipe
Recipe type
Path
21/October/2008 SPD CB and VFE - Piquet Training
14
SPD CB panel: test tab
If VFE problems, read VFE status and/or reset it.
Read VFE status:•Click on “STATUS VFE”
•Status will show
Reset VFE
Select CB ch
21/October/2008 SPD CB and VFE - Piquet Training
15
Extra slides
21/October/2008 SPD CB and VFE - Piquet Training
16
SPD CB panel: test tab
If VFE problems and if the expert asks for it, read VFE parameters.
t0 adjustment:
Read values by clicking on “Read”
21/October/2008 SPD CB and VFE - Piquet Training
17
SPD CB panel: test tab
If VFE problems and if the expert asks for it, read VFE parameters.
BXID delay:
Read values by clicking on “Read”
CB “MIERDA” line phases.